All MIBs › Fore-SONET-MIB › sonetPathDiagnostic
sonetPathDiagnostic
Module: Fore-SONET-MIB
OID (symbolic): Fore-SONET-MIB::sonetPathDiagnostic
OID (numeric): 1.3.6.1.4.1.326.2.2.1.1.4.1.1.1.28
Node type: OBJECT-TYPE
Type: Integer32
Access: read-write
Description: This variable controls the insertion of various types of path diagnostic bit patterns in the transmit stream. It is a bit map that is netmod specific. Under normal operation it should be set to:
1 None -- No diagnostics
2 DB3 -- Controls the insertion of eight path BIP-8 errors per frame continuously in the B3 byte. When DB3 is on, the B3 byte is inverted.
What is sonetPathDiagnostic?
A bitmapped control for injecting Path-layer error patterns into this port's transmit stream: DB3 (bit 2) inverts the B3 byte, generating eight path BIP-8 errors per frame; 1 means no diagnostics. An admin sets this temporarily to verify downstream equipment correctly reports path BIP-8 errors, then resets it to 1 afterward.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.326.2.2.1.1.4.1.1.1.28 snmpwalk -v2c -c public <target> Fore-SONET-MIB::sonetPathDiagnostic
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.326.2.2.1.1.4.1.1.1.28.1 snmpget -v2c -c public <target> Fore-SONET-MIB::sonetPathDiagnostic.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.326.2.2.1.1.4.1.1.1.28.1 i <value>
Start monitoring Fore Systems (later Marconi) ForeRunner ATM switch with SONET/SDH port modules with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Fore-SONET-MIB::sonetPathDiagnostic OID value, configure state conditions and alerts, and monitor any Fore Systems (later Marconi) ForeRunner ATM switch with SONET/SDH port modules from a single console.
OID Breakdown
Upper-level ancestors (11 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.326 | marconi | ES1000-MIB |
| 1.3.6.1.4.1.326.2 | systems | ES1000-MIB |
| 1.3.6.1.4.1.326.2.2 | atmSwitch | Fore-Common-MIB |
| 1.3.6.1.4.1.326.2.2.1 | hardware | Fore-Common-MIB |
| 1.3.6.1.4.1.326.2.2.1.1 | asx | Fore-Common-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.326.2.2.1.1.4 | foreSonetModule | Fore-SONET-MIB |
| 1.3.6.1.4.1.326.2.2.1.1.4.1 | sonetConfGroup | Fore-SONET-MIB |
| 1.3.6.1.4.1.326.2.2.1.1.4.1.1 | sonetConfTable | Fore-SONET-MIB |
| 1.3.6.1.4.1.326.2.2.1.1.4.1.1.1 | sonetConfEntry | Fore-SONET-MIB |
| 1.3.6.1.4.1.326.2.2.1.1.4.1.1.1.28 | sonetPathDiagnostic | Fore-SONET-MIB |