Fore-SONET-MIB :: sonetLineStatus

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsFore-SONET-MIBsonetLineStatus

sonetLineStatus

Module: Fore-SONET-MIB

OID (symbolic): Fore-SONET-MIB::sonetLineStatus

OID (numeric): 1.3.6.1.4.1.326.2.2.1.1.4.1.1.1.14

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: This variable indicates the Line Status of the interface. A similar variable is defined in the SONET IETF draft line configuration table as sonetLineStatus. The variable is a bit map represented as a sum, therefore, it can represent multiple defects simultaneously. The sonetLineNoDefect should be set if and only if no other flag is set. The various bit positions are: 1 sonetLineNoDefect 2 sonetLineAIS Line Alarm Indication Signal was detected. Line AIS is asserted when a 111 binary pattern is detected in bits 6,7,8 of the K2 byte for five consecutive frames. 4 sonetLineRDI Line Remote Defect Indication was detected. RDI is asserted when a 110 binary pattern is detected in bits 6,7,8 of the K2 byte for five consecutive frames.

What is sonetLineStatus?

A bitmapped summary of Line-layer defects on this port: bit 2 for Line AIS (Alarm Indication Signal detected via the K2 byte) and bit 4 for Line RDI (Remote Defect Indication), with a value of 1 meaning no defect. An admin reads this to see whether the line-layer alarm bits are clear before assuming the circuit is healthy.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.326.2.2.1.1.4.1.1.1.14
snmpwalk -v2c -c public <target> Fore-SONET-MIB::sonetLineStatus

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.326.2.2.1.1.4.1.1.1.14.1
snmpget -v2c -c public <target> Fore-SONET-MIB::sonetLineStatus.1

Start monitoring Fore Systems (later Marconi) ForeRunner ATM switch with SONET/SDH port modules with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Fore-SONET-MIB::sonetLineStatus OID value, configure state conditions and alerts, and monitor any Fore Systems (later Marconi) ForeRunner ATM switch with SONET/SDH port modules from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.326marconiES1000-MIB
1.3.6.1.4.1.326.2systemsES1000-MIB
1.3.6.1.4.1.326.2.2atmSwitchFore-Common-MIB
1.3.6.1.4.1.326.2.2.1hardwareFore-Common-MIB
1.3.6.1.4.1.326.2.2.1.1asxFore-Common-MIB
Numeric OIDNameModule
1.3.6.1.4.1.326.2.2.1.1.4foreSonetModuleFore-SONET-MIB
1.3.6.1.4.1.326.2.2.1.1.4.1sonetConfGroupFore-SONET-MIB
1.3.6.1.4.1.326.2.2.1.1.4.1.1sonetConfTableFore-SONET-MIB
1.3.6.1.4.1.326.2.2.1.1.4.1.1.1sonetConfEntryFore-SONET-MIB
1.3.6.1.4.1.326.2.2.1.1.4.1.1.1.14sonetLineStatusFore-SONET-MIB