Fore-SONET-MIB :: sonetLineBerErrorModel

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsFore-SONET-MIBsonetLineBerErrorModel

sonetLineBerErrorModel

Module: Fore-SONET-MIB

OID (symbolic): Fore-SONET-MIB::sonetLineBerErrorModel

OID (numeric): 1.3.6.1.4.1.326.2.2.1.1.4.1.1.1.36

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: This is the error distribution model to be used to identify signal degrade and signal fail conditions. errorModelRandom selects a random error distribution and declares signal conditions based on the thresholds set in sonetLineSignalDegradeBer and sonetLineSignalFailBer. errorModelBurst selects a burst error model and declares signal degrade conditions based on the thresholds set in sonetLineBipThrSeconds and sonetLineBipThrErrors. errorModelNone disables detection of signal conditions.

What is sonetLineBerErrorModel?

Selects which error model determines signal degrade/fail conditions on this port: errorModelRandom (default) uses the BER thresholds in sonetLineSignalDegradeBer/sonetLineSignalFailBer, errorModelBurst uses the burst thresholds in sonetLineBipThrSeconds/sonetLineBipThrErrors, and errorModelNone disables this detection entirely. An admin picks the model that matches the expected error characteristics of the physical medium.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.326.2.2.1.1.4.1.1.1.36
snmpwalk -v2c -c public <target> Fore-SONET-MIB::sonetLineBerErrorModel

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.326.2.2.1.1.4.1.1.1.36.1
snmpget -v2c -c public <target> Fore-SONET-MIB::sonetLineBerErrorModel.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.326.2.2.1.1.4.1.1.1.36.1 i <value>

Start monitoring Fore Systems (later Marconi) ForeRunner ATM switch with SONET/SDH port modules with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Fore-SONET-MIB::sonetLineBerErrorModel OID value, configure state conditions and alerts, and monitor any Fore Systems (later Marconi) ForeRunner ATM switch with SONET/SDH port modules from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.326marconiES1000-MIB
1.3.6.1.4.1.326.2systemsES1000-MIB
1.3.6.1.4.1.326.2.2atmSwitchFore-Common-MIB
1.3.6.1.4.1.326.2.2.1hardwareFore-Common-MIB
1.3.6.1.4.1.326.2.2.1.1asxFore-Common-MIB
Numeric OIDNameModule
1.3.6.1.4.1.326.2.2.1.1.4foreSonetModuleFore-SONET-MIB
1.3.6.1.4.1.326.2.2.1.1.4.1sonetConfGroupFore-SONET-MIB
1.3.6.1.4.1.326.2.2.1.1.4.1.1sonetConfTableFore-SONET-MIB
1.3.6.1.4.1.326.2.2.1.1.4.1.1.1sonetConfEntryFore-SONET-MIB
1.3.6.1.4.1.326.2.2.1.1.4.1.1.1.36sonetLineBerErrorModelFore-SONET-MIB