Module: Fore-SONET-MIB
OID (symbolic): Fore-SONET-MIB::sonetFebe
OID (numeric): 1.3.6.1.4.1.326.2.2.1.1.4.1.1.1.22
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: This variable controls the insertion of line and path far end block errors. When set to sonetFebeAuto, one line or path FEBE is inserted for each line or path BIP error event, respectively. When set to sonetFebeOff, incoming line or path BIP error events do not generate FEBE events.
What is sonetFebe?
Controls whether this port generates Far End Block Error indications back toward the far end for every line/path BIP error it detects: sonetFebeAuto (the default) generates one FEBE per BIP error event, sonetFebeOff suppresses them. An admin would disable this only to stop FEBE reporting during isolated testing of this port.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.326.2.2.1.1.4.1.1.1.22 snmpwalk -v2c -c public <target> Fore-SONET-MIB::sonetFebe
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.326.2.2.1.1.4.1.1.1.22.1 snmpget -v2c -c public <target> Fore-SONET-MIB::sonetFebe.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.326.2.2.1.1.4.1.1.1.22.1 i <value>
Start monitoring Fore Systems (later Marconi) ForeRunner ATM switch with SONET/SDH port modules with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Fore-SONET-MIB::sonetFebe OID value, configure state conditions and alerts, and monitor any Fore Systems (later Marconi) ForeRunner ATM switch with SONET/SDH port modules from a single console.
OID Breakdown
Upper-level ancestors (11 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.326 | marconi | ES1000-MIB |
| 1.3.6.1.4.1.326.2 | systems | ES1000-MIB |
| 1.3.6.1.4.1.326.2.2 | atmSwitch | Fore-Common-MIB |
| 1.3.6.1.4.1.326.2.2.1 | hardware | Fore-Common-MIB |
| 1.3.6.1.4.1.326.2.2.1.1 | asx | Fore-Common-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.326.2.2.1.1.4 | foreSonetModule | Fore-SONET-MIB |
| 1.3.6.1.4.1.326.2.2.1.1.4.1 | sonetConfGroup | Fore-SONET-MIB |
| 1.3.6.1.4.1.326.2.2.1.1.4.1.1 | sonetConfTable | Fore-SONET-MIB |
| 1.3.6.1.4.1.326.2.2.1.1.4.1.1.1 | sonetConfEntry | Fore-SONET-MIB |
| 1.3.6.1.4.1.326.2.2.1.1.4.1.1.1.22 | sonetFebe | Fore-SONET-MIB |