deviceAlarmStatus

Module: EMSNetrake-MIB

OID (symbolic): EMSNetrake-MIB::deviceAlarmStatus

OID (numeric): 1.3.6.1.4.1.10950.1.2.1.1.1.5

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Overall alarm status of the device based on highest severity alarm active on the device

What is deviceAlarmStatus?

Reports a single summary alarm severity for the device, set to the highest severity among all alarms currently active on it, ranging from unknown or clear up through minor, major, and critical. It lets an admin triage device health at a glance across the managed devices table without inspecting every individual alarm entry. For example, a device showing critical here tells the admin to check the emsActiveAlarmTable for that device's alarm details before anything else.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.10950.1.2.1.1.1.5
snmpwalk -v2c -c public <target> EMSNetrake-MIB::deviceAlarmStatus

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.10950.1.2.1.1.1.5.1
snmpget -v2c -c public <target> EMSNetrake-MIB::deviceAlarmStatus.1

Start monitoring Netrake session border controller (SBC) appliance with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the EMSNetrake-MIB::deviceAlarmStatus OID value, configure state conditions and alerts, and monitor any Netrake session border controller (SBC) appliance from a single console.

How to Use in IPNetwork Monitor

Select a Netrake session border controller (SBC) appliance as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type deviceAlarmStatus into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. It reports the overall alarm status of the device based on highest severity alarm active on the device. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is an INTEGER-type OID, Value bounds is the most useful condition here — trigger an alert if the value is anything other than 'clear', since that indicates the condition this object reports has changed to one worth investigating. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.10950netrakeEMSNetrake-MIB
1.3.6.1.4.1.10950.1productsEMSNetrake-MIB
1.3.6.1.4.1.10950.1.2emsEMSNetrake-MIB
1.3.6.1.4.1.10950.1.2.1managedDevicesEMSNetrake-MIB
1.3.6.1.4.1.10950.1.2.1.1managedDevicesTableEMSNetrake-MIB
1.3.6.1.4.1.10950.1.2.1.1.1managedDevicesEntryEMSNetrake-MIB
1.3.6.1.4.1.10950.1.2.1.1.1.5deviceAlarmStatusEMSNetrake-MIB