DLINK-3100-rlInterfaces :: swIfLockLimitationMode

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › DLINK-3100-rlInterfaces › swIfLockLimitationMode

swIfLockLimitationMode

Module: DLINK-3100-rlInterfaces

OID (symbolic): DLINK-3100-rlInterfaces::swIfLockLimitationMode

OID (numeric): 1.3.6.1.4.1.171.10.94.89.89.43.1.1.37

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: This variable indicates what is the learning limitation on the locked interface. Possible values: disabled - learning is stopped. The dynamic addresses associated with the port are not aged out or relearned on other port as long as the port is locked. dynamic - dynamic addresses can be learned up to the maximum dynamic addresses allowed on the port. Relearning and aging of the dynamic addresses are enabled. The learned addresses aren't kept after reset. secure-permanent - secure addresses can be learned up to the maximum addresses allowed on the port. Relearning and aging of addresses are disabled. The learned addresses are kept after reset. secure-delete-on-reset - secure addresses can be learned up to the maximum addresses allowed on the port. Relearning and aging of addresses are disabled. The learned addresses are not kept after reset.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.171.10.94.89.89.43.1.1.37
snmpwalk -v2c -c public <target> DLINK-3100-rlInterfaces::swIfLockLimitationMode

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.171.10.94.89.89.43.1.1.37.1
snmpget -v2c -c public <target> DLINK-3100-rlInterfaces::swIfLockLimitationMode.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.171.10.94.89.89.43.1.1.37.1 i <value>

Start monitoring D-Link 3100 series switches with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the DLINK-3100-rlInterfaces::swIfLockLimitationMode OID value, configure state conditions and alerts, and monitor any D-Link 3100 series switches from a single console.

OID Breakdown

Upper-level ancestors (12 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.171d_linkDE1500-MIB
1.3.6.1.4.1.171.10dlink_productsDES-1226G-MIB
1.3.6.1.4.1.171.10.94dlink_Dgs3100SeriesProdDLINK-3100-INC-MIB
1.3.6.1.4.1.171.10.94.89dgs3100_SWL2MGMT_MIBDLINK-3100-INC-MIB
1.3.6.1.4.1.171.10.94.89.89rndDLINK-3100-INC-MIB
1.3.6.1.4.1.171.10.94.89.89.43swInterfacesDLINK-3100-MIB
Numeric OIDNameModule
1.3.6.1.4.1.171.10.94.89.89.43.1swIfTableDLINK-3100-rlInterfaces
1.3.6.1.4.1.171.10.94.89.89.43.1.1swIfEntryDLINK-3100-rlInterfaces
1.3.6.1.4.1.171.10.94.89.89.43.1.1.37swIfLockLimitationModeDLINK-3100-rlInterfaces