DLINK-3100-POE-MIB :: rlPethPsePortOutputVoltage

MIB Reference — IPNetwork Monitor · Updated October 02, 2026

All MIBs › DLINK-3100-POE-MIB › rlPethPsePortOutputVoltage

rlPethPsePortOutputVoltage

Module: DLINK-3100-POE-MIB

OID (symbolic): DLINK-3100-POE-MIB::rlPethPsePortOutputVoltage

OID (numeric): 1.3.6.1.4.1.171.10.94.89.89.108.1.1.3

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: This variable indicates on the output voltage level in milli volts from rlPethPsePortIndex.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.171.10.94.89.89.108.1.1.3
snmpwalk -v2c -c public <target> DLINK-3100-POE-MIB::rlPethPsePortOutputVoltage

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.171.10.94.89.89.108.1.1.3.1
snmpget -v2c -c public <target> DLINK-3100-POE-MIB::rlPethPsePortOutputVoltage.1

Start monitoring D-Link 3100 series PoE switches with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the DLINK-3100-POE-MIB::rlPethPsePortOutputVoltage OID value, configure state conditions and alerts, and monitor any D-Link 3100 series PoE switches from a single console.

How to Use in IPNetwork Monitor

Select a D-Link 3100 series PoE switch as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type rlPethPsePortOutputVoltage into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. This variable indicates on the output voltage level in milli volts from rlPethPsePortIndex. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is an INTEGER-type OID, Value bounds is the most useful condition here — trigger an alert if the reading drifts outside the range expected for healthy operation, since an unexpected voltage swing often points to a power-supply or wiring issue. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (12 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.171d_linkDE1500-MIB
1.3.6.1.4.1.171.10dlink_productsDES-1226G-MIB
1.3.6.1.4.1.171.10.94dlink_Dgs3100SeriesProdDLINK-3100-INC-MIB
1.3.6.1.4.1.171.10.94.89dgs3100_SWL2MGMT_MIBDLINK-3100-INC-MIB
1.3.6.1.4.1.171.10.94.89.89rndDLINK-3100-INC-MIB
1.3.6.1.4.1.171.10.94.89.89.108rlPoeDLINK-3100-MIB
Numeric OIDNameModule
1.3.6.1.4.1.171.10.94.89.89.108.1rlPethPsePortTableDLINK-3100-POE-MIB
1.3.6.1.4.1.171.10.94.89.89.108.1.1rlPethPsePortEntryDLINK-3100-POE-MIB
1.3.6.1.4.1.171.10.94.89.89.108.1.1.3rlPethPsePortOutputVoltageDLINK-3100-POE-MIB