DES3528DC-L2MGMT-MIB :: swL2QOSSchedulingMaxLatency

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › DES3528DC-L2MGMT-MIB › swL2QOSSchedulingMaxLatency

swL2QOSSchedulingMaxLatency

Module: DES3528DC-L2MGMT-MIB

OID (symbolic): DES3528DC-L2MGMT-MIB::swL2QOSSchedulingMaxLatency

OID (numeric): 1.3.6.1.4.1.171.11.105.5.2.6.2.1.4

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Indicates the maximum amount of time the hardware priority queue will be allowed to transmit packets before allowing the next lowest priority queue to begin transmitting its packets. A value between 0 and 255 can be specified- with this value multiplied by 16 ms to arrive at the total allowed time for queue to transmit packets. For example, a value of 3 specifies 3*16=48 ms. The queue will continue transmitting the last packet until it is finished when the max_latency timer expires.

What is swL2QOSSchedulingMaxLatency?

Sets, for the indexed hardware priority queue, the maximum time (0-255, each unit = 16ms, so a value of 3 = 48ms per the source DESCRIPTION) that queue may transmit before yielding to the next-lower-priority queue, with the in-flight packet allowed to finish even if the timer expires. This is the time-based counterpart to swL2QOSSchedulingMaxPkts for controlling queue starvation.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.171.11.105.5.2.6.2.1.4
snmpwalk -v2c -c public <target> DES3528DC-L2MGMT-MIB::swL2QOSSchedulingMaxLatency

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.171.11.105.5.2.6.2.1.4.1
snmpget -v2c -c public <target> DES3528DC-L2MGMT-MIB::swL2QOSSchedulingMaxLatency.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.171.11.105.5.2.6.2.1.4.1 i <value>

Start monitoring D-Link DES-3528DC switch with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the DES3528DC-L2MGMT-MIB::swL2QOSSchedulingMaxLatency OID value, configure state conditions and alerts, and monitor any D-Link DES-3528DC switch from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.171d_linkDE1500-MIB
1.3.6.1.4.1.171.11dlink_mgmtDES2218-MIB
1.3.6.1.4.1.171.11.105dlink_Des3528SeriesSW3528PRIMGMT-MIB
1.3.6.1.4.1.171.11.105.5des3528dcSW3528PRIMGMT-MIB
Numeric OIDNameModule
1.3.6.1.4.1.171.11.105.5.2swL2MgmtMIBDES3528DC-L2MGMT-MIB
1.3.6.1.4.1.171.11.105.5.2.6swL2QOSMgmtDES3528DC-L2MGMT-MIB
1.3.6.1.4.1.171.11.105.5.2.6.2swL2QOSSchedulingTableDES3528DC-L2MGMT-MIB
1.3.6.1.4.1.171.11.105.5.2.6.2.1swL2QOSSchedulingEntryDES3528DC-L2MGMT-MIB
1.3.6.1.4.1.171.11.105.5.2.6.2.1.4swL2QOSSchedulingMaxLatencyDES3528DC-L2MGMT-MIB