CYCLADES-ACS5K-SYS-MIB :: cyACS5KPw1

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › CYCLADES-ACS5K-SYS-MIB › cyACS5KPw1

cyACS5KPw1

Module: CYCLADES-ACS5K-SYS-MIB

OID (symbolic): CYCLADES-ACS5K-SYS-MIB::cyACS5KPw1

OID (numeric): 1.3.6.1.4.1.2925.8.1.3.2

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: State of the first power supply

What is cyACS5KPw1?

This enumerated value reports the operational state of the first power supply slot in the ACS5000 chassis. Admins monitor it to detect a failed or missing power supply before it causes a loss of redundancy. A value of powerOFF(2) while a supply should be installed signals that power supply 1 has failed or lost input power and needs attention.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2925.8.1.3.2
snmpwalk -v2c -c public <target> CYCLADES-ACS5K-SYS-MIB::cyACS5KPw1

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2925.8.1.3.2.1
snmpget -v2c -c public <target> CYCLADES-ACS5K-SYS-MIB::cyACS5KPw1.1

Start monitoring Avocent Cyclades ACS 5000 console/terminal server (system hardware inventory) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CYCLADES-ACS5K-SYS-MIB::cyACS5KPw1 OID value, configure state conditions and alerts, and monitor any Avocent Cyclades ACS 5000 console/terminal server (system hardware inventory) from a single console.

How to Use in IPNetwork Monitor

Select an Avocent Cyclades ACS 5000 console/terminal server (system hardware inventory) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type cyACS5KPw1 into the Find box to locate it in the OID tree, then select it and click OK. It reports the state of the first power supply. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is an INTEGER-type OID, Value bounds is the most useful condition here — trigger an alert if the value is anything other than 'powerON', since that indicates the condition this object reports has changed to one worth investigating. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2925cycladesCYCLADES-MIB
1.3.6.1.4.1.2925.8cyACS5KMgmtCYCLADES-ACS5K-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2925.8.1cyACS5KSysCYCLADES-ACS5K-SYS-MIB
1.3.6.1.4.1.2925.8.1.3cyACS5KPowerCYCLADES-ACS5K-SYS-MIB
1.3.6.1.4.1.2925.8.1.3.2cyACS5KPw1CYCLADES-ACS5K-SYS-MIB