CYCLADES-ACS-SYS-MIB :: cyACSPw1

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › CYCLADES-ACS-SYS-MIB › cyACSPw1

cyACSPw1

Module: CYCLADES-ACS-SYS-MIB

OID (symbolic): CYCLADES-ACS-SYS-MIB::cyACSPw1

OID (numeric): 1.3.6.1.4.1.2925.4.1.3.2

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: State of the first power supply

What is cyACSPw1?

The operational state of the first power supply: noinstalled(0), powerON(1), or powerOFF(2), useful for spotting a failed or missing PSU in a dual-power chassis.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2925.4.1.3.2
snmpwalk -v2c -c public <target> CYCLADES-ACS-SYS-MIB::cyACSPw1

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2925.4.1.3.2.1
snmpget -v2c -c public <target> CYCLADES-ACS-SYS-MIB::cyACSPw1.1

Start monitoring Cyclades ACS/TS console (terminal) server (system inventory) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CYCLADES-ACS-SYS-MIB::cyACSPw1 OID value, configure state conditions and alerts, and monitor any Cyclades ACS/TS console (terminal) server (system inventory) from a single console.

How to Use in IPNetwork Monitor

Select a Cyclades ACS/TS console (terminal) server (system inventory) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type cyACSPw1 into the Find box to locate it in the OID tree, then select it and click OK. It reports the state of the first power supply. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is an INTEGER-type OID, Value bounds is the most useful condition here — trigger an alert if the value is anything other than 'powerON', since that indicates the condition this object reports has changed to one worth investigating. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2925cycladesCYCLADES-MIB
1.3.6.1.4.1.2925.4cyACSMgmtCYCLADES-ACS-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2925.4.1cyACSSysCYCLADES-ACS-SYS-MIB
1.3.6.1.4.1.2925.4.1.3cyACSPowerCYCLADES-ACS-SYS-MIB
1.3.6.1.4.1.2925.4.1.3.2cyACSPw1CYCLADES-ACS-SYS-MIB