All MIBs › CYCLADES-ACS-SYS-MIB › cyACSPw1
cyACSPw1
Module: CYCLADES-ACS-SYS-MIB
OID (symbolic): CYCLADES-ACS-SYS-MIB::cyACSPw1
OID (numeric): 1.3.6.1.4.1.2925.4.1.3.2
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: State of the first power supply
What is cyACSPw1?
The operational state of the first power supply: noinstalled(0), powerON(1), or powerOFF(2), useful for spotting a failed or missing PSU in a dual-power chassis.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2925.4.1.3.2 snmpwalk -v2c -c public <target> CYCLADES-ACS-SYS-MIB::cyACSPw1
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.2925.4.1.3.2.1 snmpget -v2c -c public <target> CYCLADES-ACS-SYS-MIB::cyACSPw1.1
Start monitoring Cyclades ACS/TS console (terminal) server (system inventory) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CYCLADES-ACS-SYS-MIB::cyACSPw1 OID value, configure state conditions and alerts, and monitor any Cyclades ACS/TS console (terminal) server (system inventory) from a single console.
How to Use in IPNetwork Monitor
OID Breakdown
Upper-level ancestors (8 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.2925 | cyclades | CYCLADES-MIB |
| 1.3.6.1.4.1.2925.4 | cyACSMgmt | CYCLADES-ACS-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.2925.4.1 | cyACSSys | CYCLADES-ACS-SYS-MIB |
| 1.3.6.1.4.1.2925.4.1.3 | cyACSPower | CYCLADES-ACS-SYS-MIB |