CYCLADES-ACS-PM-MIB :: cyNumberOfPM

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › CYCLADES-ACS-PM-MIB › cyNumberOfPM

cyNumberOfPM

Module: CYCLADES-ACS-PM-MIB

OID (symbolic): CYCLADES-ACS-PM-MIB::cyNumberOfPM

OID (numeric): 1.3.6.1.4.1.2925.4.5.1

Node type: OBJECT-TYPE

Type: Integer32

Access: read-only

Description: The total number of PM's connected on the unit

What is cyNumberOfPM?

This integer reports the total number of Power Manager (PM) units connected to the Cyclades ACS console server. An admin checks it to confirm how many PDU/power-controller units the box has discovered before trying to poll or control individual outlets. For example, a value of 3 means three daisy-chained PM units are attached and addressable through this MIB.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2925.4.5.1
snmpwalk -v2c -c public <target> CYCLADES-ACS-PM-MIB::cyNumberOfPM

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2925.4.5.1.1
snmpget -v2c -c public <target> CYCLADES-ACS-PM-MIB::cyNumberOfPM.1

Start monitoring Cyclades ACS console server (attached power management/PDU) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CYCLADES-ACS-PM-MIB::cyNumberOfPM OID value, configure state conditions and alerts, and monitor any Cyclades ACS console server (attached power management/PDU) from a single console.

How to Use in IPNetwork Monitor

Select a Cyclades ACS console server (attached power management/PDU) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type cyNumberOfPM into the Find box to locate it in the OID tree, then select it and click OK. The total number of PM's connected on the unit. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is an Integer32-type OID, Value bounds is the most useful condition here — trigger an alert if the count changes from its expected baseline, since that would indicate the underlying set of items changed unexpectedly. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2925cycladesCYCLADES-MIB
1.3.6.1.4.1.2925.4cyACSMgmtCYCLADES-ACS-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2925.4.5cyPMCYCLADES-ACS-PM-MIB
1.3.6.1.4.1.2925.4.5.1cyNumberOfPMCYCLADES-ACS-PM-MIB