COM21-HCXSTUPRXY-MIB :: stuCurrEtherRunts

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCOM21-HCXSTUPRXY-MIBstuCurrEtherRunts

stuCurrEtherRunts

Module: COM21-HCXSTUPRXY-MIB

OID (symbolic): COM21-HCXSTUPRXY-MIB::stuCurrEtherRunts

OID (numeric): 1.3.6.1.4.1.1141.3.9.1.1.2

Node type: OBJECT-TYPE

Type: Gauge32

Access: read-only

Description: Contains number of runt packets received by the ComPort in the current 15minute period. This data is held on the ComPort.

What is stuCurrEtherRunts?

This Gauge32, held on the ComPort, counts runt (undersized) Ethernet packets received in the current 15-minute period. A rising runt count typically points to a cabling problem or a failing network interface card on the subscriber's own equipment rather than the STU or the cable plant. For example, a customer with a damaged Ethernet patch cable to their STU would show a steadily climbing stuCurrEtherRunts count during the affected session.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1141.3.9.1.1.2
snmpwalk -v2c -c public <target> COM21-HCXSTUPRXY-MIB::stuCurrEtherRunts

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1141.3.9.1.1.2.1
snmpget -v2c -c public <target> COM21-HCXSTUPRXY-MIB::stuCurrEtherRunts.1

Start monitoring Com21 ComController HCX ComPort proxy (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the COM21-HCXSTUPRXY-MIB::stuCurrEtherRunts OID value, configure state conditions and alerts, and monitor any Com21 ComController HCX ComPort proxy (legacy) from a single console.

How to Use in IPNetwork Monitor

Select a Com21 ComController HCX ComPort proxy (legacy) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type stuCurrEtherRunts into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. Contains number of runt packets received by the ComPort in the current 15minute period. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Gauge32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases sharply between polls relative to its normal baseline, since an unexpected spike often reflects a real change in traffic or activity. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1141com21COM21-HCX-MIB
1.3.6.1.4.1.1141.3com21StuCOM21-HCX-MIB
Numeric OIDNameModule
1.3.6.1.4.1.1141.3.9com21StuEtherStatsGroupCOM21-HCXSTUPRXY-MIB
1.3.6.1.4.1.1141.3.9.1com21StuEtherStatsTableCOM21-HCXSTUPRXY-MIB
1.3.6.1.4.1.1141.3.9.1.1com21StuEtherStatsEntryCOM21-HCXSTUPRXY-MIB
1.3.6.1.4.1.1141.3.9.1.1.2stuCurrEtherRuntsCOM21-HCXSTUPRXY-MIB