ATMF-CES-MIB :: atmfDS1E1CESReassCells

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › ATMF-CES-MIB › atmfDS1E1CESReassCells

atmfDS1E1CESReassCells

Module: ATMF-CES-MIB

OID (symbolic): ATMF-CES-MIB::atmfDS1E1CESReassCells

OID (numeric): 1.3.6.1.4.1.353.5.2.1.2.1.1

Node type: OBJECT-TYPE

Type: Counter32

Access: read-only

Description: This count gives the number of cells played out to the DS1/E1 Service Interface. It excludes cells that were discarded for any reason, including cells that were not used due to being declared misinserted, or discarded while the reassembler was waiting to achieve synchronization.

What is atmfDS1E1CESReassCells?

This is a read-only counter measuring ATM cells successfully reassembled and delivered to the DS1/E1 interface. It tracks circuit emulation service delivery, excluding discarded or misinserted cells. A counter of 1000000 shows one million cells were successfully reassembled.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.353.5.2.1.2.1.1
snmpwalk -v2c -c public <target> ATMF-CES-MIB::atmfDS1E1CESReassCells

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.353.5.2.1.2.1.1.1
snmpget -v2c -c public <target> ATMF-CES-MIB::atmfDS1E1CESReassCells.1

Start monitoring ATM circuit-emulation gateway/edge devices with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ATMF-CES-MIB::atmfDS1E1CESReassCells OID value, configure state conditions and alerts, and monitor any ATM circuit-emulation gateway/edge devices from a single console.

How to Use in IPNetwork Monitor

Select an ATM circuit-emulation gateway/edge device as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type atmfDS1E1CESReassCells into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. This count gives the number of cells played out to the DS1/E1 Service Interface. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases between polls, since a rising count of errors, failures, or discards often points to a real underlying problem. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.353atmForumATM-DXI-MIB
1.3.6.1.4.1.353.5atmForumNetworkManagementATM-FORUM-SNMP-M4-MIB
1.3.6.1.4.1.353.5.2atmfCESmibATMF-CES
Numeric OIDNameModule
1.3.6.1.4.1.353.5.2.1atmfDS1E1CESmibATMF-CES-MIB
1.3.6.1.4.1.353.5.2.1.2atmfDS1E1CESStatsTableATMF-CES-MIB
1.3.6.1.4.1.353.5.2.1.2.1atmfDS1E1CESStatsEntryATMF-CES-MIB
1.3.6.1.4.1.353.5.2.1.2.1.1atmfDS1E1CESReassCellsATMF-CES-MIB