APPIAN-CHASSIS-MIB :: acChassisSysUpTime

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsAPPIAN-CHASSIS-MIBacChassisSysUpTime

acChassisSysUpTime

Module: APPIAN-CHASSIS-MIB

OID (symbolic): APPIAN-CHASSIS-MIB::acChassisSysUpTime

OID (numeric): 1.3.6.1.4.1.2785.2.1.2.1.24

Node type: OBJECT-TYPE

Type: TimeTicks

Access: read-only

Description: The time in hundredths of a second since the network management portion of the system was last reinitialized. The acChassisSysUpTime field is mapped to the MIB-II sysUptime field. Note: The value of acChassisSysUpTime will not be reset when an Active to Standby failover occurs on the Switch Control Processor(s). The acChassisSysUpTime value will only be reset when the whole system has been reset.

What is acChassisSysUpTime?

Reports the elapsed time in hundredths of a second since the network management system on this chassis was last reinitialized, mapping to MIB-II sysUpTime. Notably, this counter is not reset during an active-to-standby Switch Control Processor failover.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2785.2.1.2.1.24
snmpwalk -v2c -c public <target> APPIAN-CHASSIS-MIB::acChassisSysUpTime

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2785.2.1.2.1.24.1
snmpget -v2c -c public <target> APPIAN-CHASSIS-MIB::acChassisSysUpTime.1

Start monitoring Appian Communications OSAP SONET/optical access platform (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the APPIAN-CHASSIS-MIB::acChassisSysUpTime OID value, configure state conditions and alerts, and monitor any Appian Communications OSAP SONET/optical access platform (legacy) from a single console.

How to Use in IPNetwork Monitor

Select an Appian Communications OSAP SONET/optical access platform as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type acChassisSysUpTime into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. It reports how long the management portion of this chassis has been running since it was last reinitialized, in hundredths of a second. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a TimeTicks-type OID, Value bounds is the most useful condition here — trigger an alert if the value is unexpectedly low (e.g. under 10 minutes), since that indicates a recent, possibly unplanned, reboot. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2785appianAPPIAN-SMI-MIB
1.3.6.1.4.1.2785.2acOsapAPPIAN-SMI-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2785.2.1acChassisAPPIAN-CHASSIS-MIB
1.3.6.1.4.1.2785.2.1.2acChassisTableAPPIAN-CHASSIS-MIB
1.3.6.1.4.1.2785.2.1.2.1acChassisEntryAPPIAN-CHASSIS-MIB
1.3.6.1.4.1.2785.2.1.2.1.24acChassisSysUpTimeAPPIAN-CHASSIS-MIB