All MIBs › ADH-NETCOM-MIB › upperLimit
upperLimit
Module: ADH-NETCOM-MIB
OID (symbolic): ADH-NETCOM-MIB::upperLimit
OID (numeric): 1.3.6.1.4.1.32185.2.2.2
Node type: OBJECT-TYPE
Type: DisplayString
Access: read-only
Description: The pressure, in PSI or mbar, which the unit pressurizes to
What is upperLimit?
This OID sets the target pressure (in PSI or mbar) to which the compressor pumps before stopping. This defines the normal operating range; the system cycles between the lower and upper limits. An example value of '500' means the compressor stops once system pressure reaches 500 PSI, establishing a 100-PSI operating band.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.32185.2.2.2 snmpwalk -v2c -c public <target> ADH-NETCOM-MIB::upperLimit
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.32185.2.2.2.1 snmpget -v2c -c public <target> ADH-NETCOM-MIB::upperLimit.1
Start monitoring Environmental Technology Inc. compressor/environment controllers with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADH-NETCOM-MIB::upperLimit OID value, configure state conditions and alerts, and monitor any Environmental Technology Inc. compressor/environment controllers from a single console.
OID Breakdown
Upper-level ancestors (6 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.32185 | environmentalTechnology | ADH-NETCOM-MIB |
| 1.3.6.1.4.1.32185.2 | netcom | ADH-NETCOM-MIB |
| 1.3.6.1.4.1.32185.2.2 | paramsInfo | ADH-NETCOM-MIB |
| 1.3.6.1.4.1.32185.2.2.2 | upperLimit | ADH-NETCOM-MIB |