All MIBs › ADH-NETCOM-MIB › alarms
alarms
Module: ADH-NETCOM-MIB
OID (symbolic): ADH-NETCOM-MIB::alarms
OID (numeric): 1.3.6.1.4.1.32185.2.1.6
Node type: OBJECT-TYPE
Type: DisplayString
Access: read-only
Description: Current alarm conditions: is a list of them Each character has a - for no alarm, or an A or W if there is an alarm. A means alarm (serious), W means a warning (not so serious). Severity levels may later change. List of alarms: (later versions may add more): A1: Low pressure A2: High pressure W3: High duty cycle W4: High temperature W5: Low temperature W6: Unused A7: Canister 1 won't heat A8: Canister 1 won't cool A9: Canister 2 won't heat A10: Canister 2 won't cool A11: Unable to pressurize A12: Dew point alarm W13: Compressor timeout (for future use) W14: Communications error A15: Canister 1 thermistor bad A16: Canister 2 thermistor bad A17: Ambient thermistor bad A18: Overpressure A19: Bad calibrations in EEPROM A20: Bad limits in EEPROM A21: Short cycling A22: Pump shut down due to error condition
What is alarms?
This OID contains a 30-character string where each position represents a specific alarm type, with '-' for no alarm, 'A' for critical alarm, or 'W' for warning. Monitoring systems check this to alert operators to problems such as low/high pressure (A1/A2), high duty cycle (W3), temperature issues (W4/W5), or equipment failures. An example value of 'A1--W4--' indicates a low-pressure alarm and high-temperature warning are active.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.32185.2.1.6 snmpwalk -v2c -c public <target> ADH-NETCOM-MIB::alarms
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.32185.2.1.6.1 snmpget -v2c -c public <target> ADH-NETCOM-MIB::alarms.1
Start monitoring Environmental Technology Inc. compressor/environment controllers with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADH-NETCOM-MIB::alarms OID value, configure state conditions and alerts, and monitor any Environmental Technology Inc. compressor/environment controllers from a single console.
OID Breakdown
Upper-level ancestors (6 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.32185 | environmentalTechnology | ADH-NETCOM-MIB |
| 1.3.6.1.4.1.32185.2 | netcom | ADH-NETCOM-MIB |
| 1.3.6.1.4.1.32185.2.1 | statusInfo | ADH-NETCOM-MIB |
| 1.3.6.1.4.1.32185.2.1.6 | alarms | ADH-NETCOM-MIB |