prConPortVLANConfigMode

Module: A3COM0420-SWITCH-EXTENSIONS

OID (symbolic): A3COM0420-SWITCH-EXTENSIONS::prConPortVLANConfigMode

OID (numeric): 1.3.6.1.4.1.43.10.34.2.1.1.1

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: This object specifies the VLAN mode to be used. Setting it to

portMode(3) requires the user to configure the port's VLAN

membership explicitly, whereas autoSelect(4) causes it to

acquire its membership from the VLAN Server.

VLAN mode can be set for the whole stack or for individual

ports. When a unit is initialised to factory defaults,

prConPortVLANConfigMode for every port is set to useDefault(2),

and the actual setting for the port is decided by the value of

prConStackVLANConfigMode. The other values of this object allow

the setting to be varied for the individual port.

What is prConPortVLANConfigMode?

This OID controls how a port acquires its VLAN membership—either explicitly configured or automatically from a VLAN server. Network engineers write this to set portMode for manual VLAN assignment or autoSelect for dynamic server-based membership. For example, setting portMode(3) requires the administrator to explicitly assign each port to VLANs.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.43.10.34.2.1.1.1
snmpwalk -v2c -c public <target> A3COM0420-SWITCH-EXTENSIONS::prConPortVLANConfigMode

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.43.10.34.2.1.1.1.1
snmpget -v2c -c public <target> A3COM0420-SWITCH-EXTENSIONS::prConPortVLANConfigMode.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.43.10.34.2.1.1.1.1 i <value>

Start monitoring Legacy 3Com switch stacking equipment with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the A3COM0420-SWITCH-EXTENSIONS::prConPortVLANConfigMode OID value, configure state conditions and alerts, and monitor any Legacy 3Com switch stacking equipment from a single console.

OID Breakdown

Upper-level ancestors (12 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.43a3ComA3COM-AUDL-R1-MIB
1.3.6.1.4.1.43.10genericA3Com-products-MIB
1.3.6.1.4.1.43.10.34brasica2A3COM0004-GENERIC
1.3.6.1.4.1.43.10.34.2switchConfigGroupA3COM0054-BRASICA2-SPECIFIC
1.3.6.1.4.1.43.10.34.2.1prConfigPortTableA3COM0054-BRASICA2-SPECIFIC
1.3.6.1.4.1.43.10.34.2.1.1prConfigPortEntryA3COM0054-BRASICA2-SPECIFIC
Numeric OIDNameModule
1.3.6.1.4.1.43.10.34.2.1.1.1prConPortVLANConfigModeA3COM0420-SWITCH-EXTENSIONS