A3COM-HUAWEI-DHCP-SERVER-MIB :: h3cDHCPServerReqTimes

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsA3COM-HUAWEI-DHCP-SERVER-MIBh3cDHCPServerReqTimes

h3cDHCPServerReqTimes

Module: A3COM-HUAWEI-DHCP-SERVER-MIB

OID (symbolic): A3COM-HUAWEI-DHCP-SERVER-MIB::h3cDHCPServerReqTimes

OID (numeric): 1.3.6.1.4.1.43.45.1.10.2.101.1.2

Node type: OBJECT-TYPE

Type: Counter32

Access: read-only

Description: Number of requests received by the DHCP server.

What is h3cDHCPServerReqTimes?

Cumulative count of all DHCP request messages (DISCOVER, REQUEST) received by the server since startup. This metric shows overall DHCP activity and demand on the server. A counter value of 50,000 indicates 50,000 total DHCP requests have been processed by the server.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.43.45.1.10.2.101.1.2
snmpwalk -v2c -c public <target> A3COM-HUAWEI-DHCP-SERVER-MIB::h3cDHCPServerReqTimes

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.43.45.1.10.2.101.1.2.1
snmpget -v2c -c public <target> A3COM-HUAWEI-DHCP-SERVER-MIB::h3cDHCPServerReqTimes.1

Start monitoring H3C routers and switches with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the A3COM-HUAWEI-DHCP-SERVER-MIB::h3cDHCPServerReqTimes OID value, configure state conditions and alerts, and monitor any H3C routers and switches from a single console.

How to Use in IPNetwork Monitor

Select an H3C router or switch as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type h3cDHCPServerReqTimes into the Find box to locate it in the OID tree, then select it and click OK. It reports the number of requests received by the DHCP server. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases sharply between polls relative to its normal baseline, since an unexpected spike often reflects a real change in traffic or activity. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.43a3ComA3COM-BRIDGE-R3-MIB
1.3.6.1.4.1.43.45jv_mibA3COM-HUAWEI-OID-MIB
1.3.6.1.4.1.43.45.1huaweiA3COM-HUAWEI-OID-MIB
1.3.6.1.4.1.43.45.1.10h3cA3COM-HUAWEI-OID-MIB
1.3.6.1.4.1.43.45.1.10.2h3cCommonA3COM-HUAWEI-OID-MIB
Numeric OIDNameModule
1.3.6.1.4.1.43.45.1.10.2.101h3cDHCPServerA3COM-HUAWEI-DHCP-SERVER-MIB
1.3.6.1.4.1.43.45.1.10.2.101.1h3cDHCPServerObjectsA3COM-HUAWEI-DHCP-SERVER-MIB
1.3.6.1.4.1.43.45.1.10.2.101.1.2h3cDHCPServerReqTimesA3COM-HUAWEI-DHCP-SERVER-MIB