Wellfleet-VCCT-MIB DEFINITIONS ::= BEGIN -- Created by mdl2asn version 3.1 -- Creation date: Wed Sep 6 16:57:28 EDT 1995 -- Edited by sbasu IMPORTS OBJECT-TYPE FROM RFC-1212 wfVcctGroup FROM Wellfleet-COMMON-MIB; wfVcct OBJECT IDENTIFIER ::= { wfVcctGroup 1 } wfVcctDelete OBJECT-TYPE SYNTAX INTEGER { created(1), deleted(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Create/Delete parameter. Default is created. User perform an SNMP SET operation on this object in order to create/delete VCCT" DEFVAL { created } ::= { wfVcct 1 } wfVcctDisable OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable/Disable parameter. Default is enabled. User perform an SNMP SET operation on this object in order to enable/disable VCCT" DEFVAL { enabled } ::= { wfVcct 2 } wfVcctState OBJECT-TYPE SYNTAX INTEGER { up(1), down(2), init(3), notpresent(4) } ACCESS read-only STATUS mandatory DESCRIPTION "The current state of VCCT subsystem" DEFVAL { down } ::= { wfVcct 3 } wfVcctTable OBJECT-TYPE SYNTAX SEQUENCE OF WfVcctEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of Virtual Circuit Config Objects" ::= { wfVcctGroup 2 } wfVcctEntry OBJECT-TYPE SYNTAX WfVcctEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the Virtual Circuit Config Table" INDEX { wfVcctEntrySlot, wfVcctEntryCct } ::= { wfVcctTable 1 } WfVcctEntry ::= SEQUENCE { wfVcctEntryDelete INTEGER, wfVcctEntryDisable INTEGER, wfVcctEntryState INTEGER, wfVcctEntrySlot INTEGER, wfVcctEntryCct INTEGER, wfVcctEntryNumClients INTEGER, wfVcctEntryServiceType INTEGER } wfVcctEntryDelete OBJECT-TYPE SYNTAX INTEGER { created(1), deleted(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Create/Delete parameter. Default is created. User perform an SNMP SET operation on this object in order to create/delete the Virtual Circuit gate" DEFVAL { created } ::= { wfVcctEntry 1 } wfVcctEntryDisable OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable/Disable parameter. Default is enabled. User perform an SNMP SET operation on this object in order to enable/disable the Virtual Circuit gate" DEFVAL { enabled } ::= { wfVcctEntry 2 } wfVcctEntryState OBJECT-TYPE SYNTAX INTEGER { coisapwait(1), connectwait(2), connectrspwait(3), connectrcv(4), disconnectrspwait(5) } ACCESS read-only STATUS mandatory DESCRIPTION "Current state of the virtual circuit gate" DEFVAL { coisapwait } ::= { wfVcctEntry 3 } wfVcctEntrySlot OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Slot that the Virtual Circuit gate is running on" ::= { wfVcctEntry 4 } wfVcctEntryCct OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Circuit number of this Virtual Circuit gate" ::= { wfVcctEntry 5 } wfVcctEntryNumClients OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Total number of clients registered on this Virtual Circuit Gate" ::= { wfVcctEntry 6 } wfVcctEntryServiceType OBJECT-TYPE SYNTAX INTEGER { dlcClientApi(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Type of Service being provided by this Virtual Circuit gate" DEFVAL { dlcClientApi } ::= { wfVcctEntry 7 } END -- Wellfleet-VCCT-MIB