Wellfleet-HWF-MIB DEFINITIONS ::= BEGIN -- Created by mdl2asn version 3.1 -- Creation date: Wed Aug 30 16:42:27 EDT 1995 IMPORTS OBJECT-TYPE FROM RFC-1212 wfHwFGroup FROM Wellfleet-COMMON-MIB; wfHwfTable OBJECT-TYPE SYNTAX SEQUENCE OF WfHwfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The following table will contain information about a collection of Hardware Filter (HWF) driver records. Only one HWF driver may be spawned, by the loader, on a given slot. Hence, only the slot number is used as the instance identifier into the table." ::= { wfHwFGroup 1 } wfHwfEntry OBJECT-TYPE SYNTAX WfHwfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Slot number used as instance identifier." INDEX { wfHwfSlot } ::= { wfHwfTable 1 } WfHwfEntry ::= SEQUENCE { wfHwfDelete INTEGER, wfHwfEnable INTEGER, wfHwfState INTEGER, wfHwfSlot INTEGER, wfHwfAvailableLines INTEGER } wfHwfDelete OBJECT-TYPE SYNTAX INTEGER { created(1), deleted(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Create/delete parameter." DEFVAL { created } ::= { wfHwfEntry 1 } wfHwfEnable OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable/disable parameter." DEFVAL { enabled } ::= { wfHwfEntry 2 } wfHwfState OBJECT-TYPE SYNTAX INTEGER { up(1), down(2), init(3), notpresent(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Driver state variable." DEFVAL { notpresent } ::= { wfHwfEntry 3 } wfHwfSlot OBJECT-TYPE SYNTAX INTEGER(1..14) ACCESS read-only STATUS mandatory DESCRIPTION "Slot number -- instance ID." ::= { wfHwfEntry 4 } wfHwfAvailableLines OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of available lines on module." ::= { wfHwfEntry 5 } wfHwfLineTable OBJECT-TYPE SYNTAX SEQUENCE OF WfHwfLineEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The following table will contain information about a collection of Hardware Filter (HWF) line records." ::= { wfHwFGroup 2 } wfHwfLineEntry OBJECT-TYPE SYNTAX WfHwfLineEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Slot number and line number used as instance identifier." INDEX { wfHwfLineSlot, wfHwfLineNumber } ::= { wfHwfLineTable 1 } WfHwfLineEntry ::= SEQUENCE { wfHwfLineState INTEGER, wfHwfLineSlot INTEGER, wfHwfLineNumber INTEGER, wfHwfLineCct INTEGER, wfHwfLineCapableMaxTblSize INTEGER, wfHwfLineCurrentTblSize INTEGER, wfHwfLineCurrentUsedEntries INTEGER, wfHwfLineDroppedFrames INTEGER } wfHwfLineState OBJECT-TYPE SYNTAX INTEGER { operational(1), disabled(2), full(3) } ACCESS read-only STATUS mandatory DESCRIPTION "State of filtering hardware on a per line basis." DEFVAL { disabled } ::= { wfHwfLineEntry 1 } wfHwfLineSlot OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Slot number -- instance ID." ::= { wfHwfLineEntry 2 } wfHwfLineNumber OBJECT-TYPE SYNTAX INTEGER { one(1), two(2), three(3), four(4), five(5) } ACCESS read-only STATUS mandatory DESCRIPTION "Line number -- instance ID." ::= { wfHwfLineEntry 3 } wfHwfLineCct OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Circuit number associated with a line." ::= { wfHwfLineEntry 4 } wfHwfLineCapableMaxTblSize OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This attribute specifies the maximum number of table entries capable of being used by a line based upon actual hardware filter devices present and available." ::= { wfHwfLineEntry 5 } wfHwfLineCurrentTblSize OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Current capacity of the hardware filter table. Hardware filter table resources are dynamically allocated (in increments of 256) on an as-needed basis up to the available table size." ::= { wfHwfLineEntry 6 } wfHwfLineCurrentUsedEntries OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of hardware filter table entries used." ::= { wfHwfLineEntry 7 } wfHwfLineDroppedFrames OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames dropped because of hardware filter match." ::= { wfHwfLineEntry 8 } END -- Wellfleet-HWF-MIB