Wellfleet-DS3-MIB DEFINITIONS ::= BEGIN -- Created by mdl2asn version 3.1 -- Creation date: Wed Aug 30 16:40:18 EDT 1995 IMPORTS IpAddress, Counter, Gauge, TimeTicks, Opaque, enterprises, mgmt FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 TRAP-TYPE FROM RFC-1215 DisplayString, mib-2 FROM RFC1213-MIB wfDs3Group FROM Wellfleet-COMMON-MIB; wfDs3Config OBJECT-TYPE SYNTAX SEQUENCE OF WfDs3ConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The DS3 Configuration table" ::= { wfDs3Group 1 } wfDs3ConfigEntry OBJECT-TYPE SYNTAX WfDs3ConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "per circuit DS3 configuration objects; wfDs3LineIndex corresponds to Wellfleet circuit number" INDEX { wfDs3LineIndex } ::= { wfDs3Config 1 } WfDs3ConfigEntry ::= SEQUENCE { wfDs3LineIndex INTEGER, wfDs3TimeElapsed INTEGER, wfDs3ValidIntervals INTEGER, wfDs3LineType INTEGER, wfDs3ZeroCoding INTEGER, wfDs3SendCode INTEGER, wfDs3CircuitIdentifier DisplayString, wfDs3LoopbackConfig INTEGER, wfDs3LineStatus INTEGER } wfDs3LineIndex OBJECT-TYPE SYNTAX INTEGER(1..1024) ACCESS read-only STATUS mandatory DESCRIPTION "this corresponds to the Wellfleet circuit number" ::= { wfDs3ConfigEntry 1 } wfDs3TimeElapsed OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "1..900 seconds within the current 15-minute interval" ::= { wfDs3ConfigEntry 2 } wfDs3ValidIntervals OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "0..96 previous intervals that valid data were collected. This is 96 unless the CSU device was brought on line within the last 24 hours." ::= { wfDs3ConfigEntry 3 } wfDs3LineType OBJECT-TYPE SYNTAX INTEGER { other(1), ds3cbitparity(4), ds3clearchannel(5) } ACCESS read-only STATUS mandatory DESCRIPTION "the variety of DS3 implementing this circuit" ::= { wfDs3ConfigEntry 4 } wfDs3ZeroCoding OBJECT-TYPE SYNTAX INTEGER { ds3b3zs(2) } ACCESS read-only STATUS mandatory DESCRIPTION "the variety of Zero Code Suppression used on the link" ::= { wfDs3ConfigEntry 5 } wfDs3SendCode OBJECT-TYPE SYNTAX INTEGER { ds3sendnocode(2) } ACCESS read-only STATUS mandatory DESCRIPTION "the type of code being sent across the DS3 circuit by the CSU" ::= { wfDs3ConfigEntry 6 } wfDs3CircuitIdentifier OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "the transmission vendor's circuit identifier" ::= { wfDs3ConfigEntry 7 } wfDs3LoopbackConfig OBJECT-TYPE SYNTAX INTEGER { ds3noloop(1), ds3mgrpayloadloop(2), ds3mgrlineloop(3), ds3netreqpayloadloop(4), ds3netreqlineloop(5), ds3otherloop(6) } ACCESS read-only STATUS mandatory DESCRIPTION "the loopback state of the CSU" ::= { wfDs3ConfigEntry 8 } wfDs3LineStatus OBJECT-TYPE SYNTAX INTEGER { ds3noalarm(1), ds3farendalarm(2), ds3alarmindicationsignal(4), ds3lossofframe(8), ds3lossofsignal(16), ds3loopbackstate(32) } ACCESS read-only STATUS mandatory DESCRIPTION "the state of the DS3 line" ::= { wfDs3ConfigEntry 9 } wfDs3Current OBJECT-TYPE SYNTAX SEQUENCE OF WfDs3CurrentEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The DS3 Current table" ::= { wfDs3Group 2 } wfDs3CurrentEntry OBJECT-TYPE SYNTAX WfDs3CurrentEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "per circuit DS3 current objects - wfDs3CurrentIndex corresponds to Wellfleet circuit number" INDEX { wfDs3CurrentIndex } ::= { wfDs3Current 1 } WfDs3CurrentEntry ::= SEQUENCE { wfDs3CurrentIndex INTEGER, wfDs3CurrentESs Counter, wfDs3CurrentSESs Counter, wfDs3CurrentSEFs Counter, wfDs3CurrentUASs Counter, wfDs3CurrentBPVs Counter, wfDs3CurrentCVs Counter } wfDs3CurrentIndex OBJECT-TYPE SYNTAX INTEGER(1..1024) ACCESS read-only STATUS mandatory DESCRIPTION "this corresponds to the Wellfleet circuit number" ::= { wfDs3CurrentEntry 1 } wfDs3CurrentESs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "the count of errored seconds in the current interval" ::= { wfDs3CurrentEntry 2 } wfDs3CurrentSESs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "the count of severely errored seconds in the current interval" ::= { wfDs3CurrentEntry 3 } wfDs3CurrentSEFs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "the count of severely errored framing seconds in the current interval" ::= { wfDs3CurrentEntry 4 } wfDs3CurrentUASs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "the number of unavailable seconds in the current interval" ::= { wfDs3CurrentEntry 5 } wfDs3CurrentBPVs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "the count of bipolar violations in the current interval" ::= { wfDs3CurrentEntry 6 } wfDs3CurrentCVs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "the count of code violation error events in the current interval" ::= { wfDs3CurrentEntry 7 } wfDs3Interval OBJECT-TYPE SYNTAX SEQUENCE OF WfDs3IntervalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The DS3 Interval table" ::= { wfDs3Group 3 } wfDs3IntervalEntry OBJECT-TYPE SYNTAX WfDs3IntervalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "per circuit DS3 interval objects - wfDs3IntervalIndex corresponds to Wellfleet circuit number, wfDs3IntervalNumber is the numbered previous 15-minute interval" INDEX { wfDs3IntervalIndex, wfDs3IntervalNumber } ::= { wfDs3Interval 1 } WfDs3IntervalEntry ::= SEQUENCE { wfDs3IntervalIndex INTEGER, wfDs3IntervalNumber INTEGER, wfDs3IntervalESs Gauge, wfDs3IntervalSESs Gauge, wfDs3IntervalSEFs Gauge, wfDs3IntervalUASs Gauge, wfDs3IntervalBPVs Gauge, wfDs3IntervalCVs Gauge } wfDs3IntervalIndex OBJECT-TYPE SYNTAX INTEGER(1..1024) ACCESS read-only STATUS mandatory DESCRIPTION "this corresponds to the Wellfleet circuit number" ::= { wfDs3IntervalEntry 1 } wfDs3IntervalNumber OBJECT-TYPE SYNTAX INTEGER(1..96) ACCESS read-only STATUS mandatory DESCRIPTION "1..96 where 1 is the most recent 15-minute interval and 96 is the least" ::= { wfDs3IntervalEntry 2 } wfDs3IntervalESs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "the count of errored seconds in the specified interval" ::= { wfDs3IntervalEntry 3 } wfDs3IntervalSESs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "the count of severely errored seconds in the specified interval" ::= { wfDs3IntervalEntry 4 } wfDs3IntervalSEFs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "the count of severely errored framing seconds in the specified interval" ::= { wfDs3IntervalEntry 5 } wfDs3IntervalUASs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "the number of unavailable seconds in the specified interval" ::= { wfDs3IntervalEntry 6 } wfDs3IntervalBPVs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "the count of bipolar violations in the specified interval" ::= { wfDs3IntervalEntry 7 } wfDs3IntervalCVs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "the count of code violation error events in the specified interval" ::= { wfDs3IntervalEntry 8 } wfDs3Total OBJECT-TYPE SYNTAX SEQUENCE OF WfDs3TotalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The DS3 Total table" ::= { wfDs3Group 4 } wfDs3TotalEntry OBJECT-TYPE SYNTAX WfDs3TotalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "per circuit DS3 total objects - wfDs3TotalIndex corresponds to Wellfleet circuit number" INDEX { wfDs3TotalIndex } ::= { wfDs3Total 1 } WfDs3TotalEntry ::= SEQUENCE { wfDs3TotalIndex INTEGER, wfDs3TotalESs Gauge, wfDs3TotalSESs Gauge, wfDs3TotalSEFs Gauge, wfDs3TotalUASs Gauge, wfDs3TotalBPVs Gauge, wfDs3TotalCVs Gauge } wfDs3TotalIndex OBJECT-TYPE SYNTAX INTEGER(1..1024) ACCESS read-only STATUS mandatory DESCRIPTION "this corresponds to the Wellfleet circuit number" ::= { wfDs3TotalEntry 1 } wfDs3TotalESs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "total count of errored seconds" ::= { wfDs3TotalEntry 2 } wfDs3TotalSESs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "total count of severely errored seconds" ::= { wfDs3TotalEntry 3 } wfDs3TotalSEFs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "total count of severely errored framing seconds" ::= { wfDs3TotalEntry 4 } wfDs3TotalUASs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "total number of unavailable seconds" ::= { wfDs3TotalEntry 5 } wfDs3TotalBPVs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "total count of bipolar violations" ::= { wfDs3TotalEntry 6 } wfDs3TotalCVs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "total count of code violation error events" ::= { wfDs3TotalEntry 7 } wfDs3FeConfig OBJECT-TYPE SYNTAX SEQUENCE OF WfDs3FeConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The DS3 Far End Configuration table" ::= { wfDs3Group 5 } wfDs3FeConfigEntry OBJECT-TYPE SYNTAX WfDs3FeConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "per circuit DS3 far end config objects - wfDs3FeIntervalIndex corresponds to Wellfleet circuit number" INDEX { wfDs3FeConfigIndex } ::= { wfDs3FeConfig 1 } WfDs3FeConfigEntry ::= SEQUENCE { wfDs3FeConfigIndex INTEGER, wfDs3FarEndEquipCode DisplayString, wfDs3FarEndLocationIDCode DisplayString, wfDs3FarEndFrameIDCode DisplayString, wfDs3FarEndUnitCode DisplayString, wfDs3FarEndFacilityIDCode DisplayString } wfDs3FeConfigIndex OBJECT-TYPE SYNTAX INTEGER(1..1024) ACCESS read-only STATUS mandatory DESCRIPTION "this corresponds to the Wellfleet circuit number" ::= { wfDs3FeConfigEntry 1 } wfDs3FarEndEquipCode OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "equipment description code - C-bit parity only" ::= { wfDs3FeConfigEntry 2 } wfDs3FarEndLocationIDCode OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "equipment location code - C-bit parity only" ::= { wfDs3FeConfigEntry 3 } wfDs3FarEndFrameIDCode OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "code for the equipment location within a building" ::= { wfDs3FeConfigEntry 4 } wfDs3FarEndUnitCode OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "code for the equipment location within a bay" ::= { wfDs3FeConfigEntry 5 } wfDs3FarEndFacilityIDCode OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "path identification code" ::= { wfDs3FeConfigEntry 6 } wfDs3FeCurrent OBJECT-TYPE SYNTAX SEQUENCE OF WfDs3FeCurrentEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The DS3 Far End Current table" ::= { wfDs3Group 6 } wfDs3FeCurrentEntry OBJECT-TYPE SYNTAX WfDs3FeCurrentEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "per circuit DS3 far end current objects wfDs3FeCurrentIndex corresponds to Wellfleet circuit number" INDEX { wfDs3FeCurrentIndex } ::= { wfDs3FeCurrent 1 } WfDs3FeCurrentEntry ::= SEQUENCE { wfDs3FeCurrentIndex INTEGER, wfDs3FeCurrentESs Counter, wfDs3FeCurrentSESs Counter, wfDs3FeCurrentCVs Counter } wfDs3FeCurrentIndex OBJECT-TYPE SYNTAX INTEGER(1..1024) ACCESS read-only STATUS mandatory DESCRIPTION "this corresponds to the Wellfleet circuit number" ::= { wfDs3FeCurrentEntry 1 } wfDs3FeCurrentESs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "the count of errored seconds in the current interval" ::= { wfDs3FeCurrentEntry 2 } wfDs3FeCurrentSESs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "the count of severely errored seconds in the current interval" ::= { wfDs3FeCurrentEntry 3 } wfDs3FeCurrentCVs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "the count of code violation error events in the current interval" ::= { wfDs3FeCurrentEntry 4 } wfDs3FeInterval OBJECT-TYPE SYNTAX SEQUENCE OF WfDs3FeIntervalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The DS3 Far End Interval table" ::= { wfDs3Group 7 } wfDs3FeIntervalEntry OBJECT-TYPE SYNTAX WfDs3FeIntervalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "per circuit DS3 far end interval objects - wfDs3FeIntervalIndex corresponds to Wellfleet circuit number, wfDs3FeIntervalNumber is the numbered previous 15-minute interval" INDEX { wfDs3FeIntervalIndex, wfDs3FeIntervalNumber } ::= { wfDs3FeInterval 1 } WfDs3FeIntervalEntry ::= SEQUENCE { wfDs3FeIntervalIndex INTEGER, wfDs3FeIntervalNumber INTEGER, wfDs3FeIntervalESs Gauge, wfDs3FeIntervalSESs Gauge, wfDs3FeIntervalCVs Gauge } wfDs3FeIntervalIndex OBJECT-TYPE SYNTAX INTEGER(1..1024) ACCESS read-only STATUS mandatory DESCRIPTION "this corresponds to the Wellfleet circuit number" ::= { wfDs3FeIntervalEntry 1 } wfDs3FeIntervalNumber OBJECT-TYPE SYNTAX INTEGER(1..96) ACCESS read-only STATUS mandatory DESCRIPTION "1..96 where 1 is the most recent 15-minute interval and 96 is the least" ::= { wfDs3FeIntervalEntry 2 } wfDs3FeIntervalESs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "the count of errored seconds in the specified interval" ::= { wfDs3FeIntervalEntry 3 } wfDs3FeIntervalSESs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "the count of severely errored seconds in the specified interval" ::= { wfDs3FeIntervalEntry 4 } wfDs3FeIntervalCVs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "the count of code violation error events in the specified interval" ::= { wfDs3FeIntervalEntry 5 } wfDs3FeTotal OBJECT-TYPE SYNTAX SEQUENCE OF WfDs3FeTotalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The DS3 Far End Total table" ::= { wfDs3Group 8 } wfDs3FeTotalEntry OBJECT-TYPE SYNTAX WfDs3FeTotalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "per circuit far end DS3 total objects - wfDs3FeTotalIndex corresponds to Wellfleet circuit number" INDEX { wfDs3FeTotalIndex } ::= { wfDs3FeTotal 1 } WfDs3FeTotalEntry ::= SEQUENCE { wfDs3FeTotalIndex INTEGER, wfDs3FeTotalESs Gauge, wfDs3FeTotalSESs Gauge, wfDs3FeTotalCVs Gauge } wfDs3FeTotalIndex OBJECT-TYPE SYNTAX INTEGER(1..1024) ACCESS read-only STATUS mandatory DESCRIPTION "this corresponds to the Wellfleet circuit number" ::= { wfDs3FeTotalEntry 1 } wfDs3FeTotalESs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "total count of errored seconds" ::= { wfDs3FeTotalEntry 2 } wfDs3FeTotalSESs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "total count of severely errored seconds" ::= { wfDs3FeTotalEntry 3 } wfDs3FeTotalCVs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "total count of code violation error events" ::= { wfDs3FeTotalEntry 4 } END -- Wellfleet-DS3-MIB