Wellfleet-DS1-MIB DEFINITIONS ::= BEGIN -- Created by mdl2asn version 3.1 -- Creation date: Wed Aug 30 16:39:57 EDT 1995 IMPORTS IpAddress, Counter, Gauge, TimeTicks, Opaque, enterprises, mgmt FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 TRAP-TYPE FROM RFC-1215 DisplayString, mib-2 FROM RFC1213-MIB wfDs1Group FROM Wellfleet-COMMON-MIB; wfDs1Config OBJECT-TYPE SYNTAX SEQUENCE OF WfDs1ConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The DS1 Configuration table" ::= { wfDs1Group 1 } wfDs1ConfigEntry OBJECT-TYPE SYNTAX WfDs1ConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "per circuit DS1 configuration objects; wfDs1LineIndex corresponds to Wellfleet circuit number" INDEX { wfDs1LineIndex } ::= { wfDs1Config 1 } WfDs1ConfigEntry ::= SEQUENCE { wfDs1LineIndex INTEGER, wfDs1TimeElapsed INTEGER, wfDs1ValidIntervals INTEGER, wfDs1LineType INTEGER, wfDs1ZeroCoding INTEGER, wfDs1SendCode INTEGER, wfDs1CircuitIdentifier DisplayString, wfDs1LoopbackConfig INTEGER, wfDs1LineStatus INTEGER } wfDs1LineIndex OBJECT-TYPE SYNTAX INTEGER(1..1024) ACCESS read-only STATUS mandatory DESCRIPTION "this corresponds to the Wellfleet circuit number" ::= { wfDs1ConfigEntry 1 } wfDs1TimeElapsed OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "1..900 seconds within the current 15-minute interval" ::= { wfDs1ConfigEntry 2 } wfDs1ValidIntervals OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "0..96 previous intervals that valid data were collected. This is 96 unless the CSU device was brought on line within the last 24 hours." ::= { wfDs1ConfigEntry 3 } wfDs1LineType OBJECT-TYPE SYNTAX INTEGER { ds1ansi-esf(4) } ACCESS read-only STATUS mandatory DESCRIPTION "the variety of DS1 implementing this circuit" ::= { wfDs1ConfigEntry 4 } wfDs1ZeroCoding OBJECT-TYPE SYNTAX INTEGER { ds1b8zs(2), ds1zbtsi(5) } ACCESS read-only STATUS mandatory DESCRIPTION "the variety of Zero Code Suppression used on the link" ::= { wfDs1ConfigEntry 5 } wfDs1SendCode OBJECT-TYPE SYNTAX INTEGER { ds1sendnocode(2) } ACCESS read-only STATUS mandatory DESCRIPTION "the type of code being sent across the DS1 circuit by the CSU" ::= { wfDs1ConfigEntry 6 } wfDs1CircuitIdentifier OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "the transmission vendor's circuit identifier" ::= { wfDs1ConfigEntry 7 } wfDs1LoopbackConfig OBJECT-TYPE SYNTAX INTEGER { ds1noloop(1), ds1mgrpayloadloop(2), ds1mgrlineloop(3), ds1netreqpayloadloop(4), ds1netreqlineloop(5), ds1otherloop(6) } ACCESS read-only STATUS mandatory DESCRIPTION "the loopback state of the CSU" ::= { wfDs1ConfigEntry 8 } wfDs1LineStatus OBJECT-TYPE SYNTAX INTEGER { ds1noalarm(1), ds1farendalarm(2), ds1alarmindicationsignal(4), ds1lossofframe(8), ds1lossofsignal(16), ds1loopbackstate(32) } ACCESS read-only STATUS mandatory DESCRIPTION "the state of the DS1 line" ::= { wfDs1ConfigEntry 9 } wfDs1Current OBJECT-TYPE SYNTAX SEQUENCE OF WfDs1CurrentEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The DS1 Current table" ::= { wfDs1Group 2 } wfDs1CurrentEntry OBJECT-TYPE SYNTAX WfDs1CurrentEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "per circuit DS1 current objects - wfDs1CurrentIndex corresponds to Wellfleet circuit number" INDEX { wfDs1CurrentIndex } ::= { wfDs1Current 1 } WfDs1CurrentEntry ::= SEQUENCE { wfDs1CurrentIndex INTEGER, wfDs1CurrentESs Counter, wfDs1CurrentSESs Counter, wfDs1CurrentSEFs Counter, wfDs1CurrentUASs Counter, wfDs1CurrentBPVs Counter, wfDs1CurrentCVs Counter } wfDs1CurrentIndex OBJECT-TYPE SYNTAX INTEGER(1..1024) ACCESS read-only STATUS mandatory DESCRIPTION "this corresponds to the Wellfleet circuit number" ::= { wfDs1CurrentEntry 1 } wfDs1CurrentESs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "the count of errored seconds in the current interval" ::= { wfDs1CurrentEntry 2 } wfDs1CurrentSESs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "the count of severely errored seconds in the current interval" ::= { wfDs1CurrentEntry 3 } wfDs1CurrentSEFs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "the count of severely errored framing seconds in the current interval" ::= { wfDs1CurrentEntry 4 } wfDs1CurrentUASs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "the number of unavailable seconds in the current interval" ::= { wfDs1CurrentEntry 5 } wfDs1CurrentBPVs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "the count of bipolar violations in the current interval" ::= { wfDs1CurrentEntry 6 } wfDs1CurrentCVs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "the count of code violation error events in the current interval" ::= { wfDs1CurrentEntry 7 } wfDs1Interval OBJECT-TYPE SYNTAX SEQUENCE OF WfDs1IntervalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The DS1 Interval table" ::= { wfDs1Group 3 } wfDs1IntervalEntry OBJECT-TYPE SYNTAX WfDs1IntervalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "per circuit DS1 interval objects - wfDs1IntervalIndex corresponds to Wellfleet circuit number, wfDs1IntervalNumber is the numbered previous 15-minute interval" INDEX { wfDs1IntervalIndex, wfDs1IntervalNumber } ::= { wfDs1Interval 1 } WfDs1IntervalEntry ::= SEQUENCE { wfDs1IntervalIndex INTEGER, wfDs1IntervalNumber INTEGER, wfDs1IntervalESs Gauge, wfDs1IntervalSESs Gauge, wfDs1IntervalSEFs Gauge, wfDs1IntervalUASs Gauge, wfDs1IntervalBPVs Gauge, wfDs1IntervalCVs Gauge } wfDs1IntervalIndex OBJECT-TYPE SYNTAX INTEGER(1..1024) ACCESS read-only STATUS mandatory DESCRIPTION "this corresponds to the Wellfleet circuit number" ::= { wfDs1IntervalEntry 1 } wfDs1IntervalNumber OBJECT-TYPE SYNTAX INTEGER(1..96) ACCESS read-only STATUS mandatory DESCRIPTION "1..96 where 1 is the most recent 15-minute interval and 96 is the least" ::= { wfDs1IntervalEntry 2 } wfDs1IntervalESs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "the count of errored seconds in the specified interval" ::= { wfDs1IntervalEntry 3 } wfDs1IntervalSESs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "the count of severely errored seconds in the specified interval" ::= { wfDs1IntervalEntry 4 } wfDs1IntervalSEFs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "the count of severely errored framing seconds in the specified interval" ::= { wfDs1IntervalEntry 5 } wfDs1IntervalUASs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "the number of unavailable seconds in the specified interval" ::= { wfDs1IntervalEntry 6 } wfDs1IntervalBPVs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "the count of bipolar violations in the specified interval" ::= { wfDs1IntervalEntry 7 } wfDs1IntervalCVs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "the count of code violation error events in the specified interval" ::= { wfDs1IntervalEntry 8 } wfDs1Total OBJECT-TYPE SYNTAX SEQUENCE OF WfDs1TotalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The DS1 Total table" ::= { wfDs1Group 4 } wfDs1TotalEntry OBJECT-TYPE SYNTAX WfDs1TotalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "per circuit DS1 total objects - wfDs1TotalIndex corresponds to Wellfleet circuit number" INDEX { wfDs1TotalIndex } ::= { wfDs1Total 1 } WfDs1TotalEntry ::= SEQUENCE { wfDs1TotalIndex INTEGER, wfDs1TotalESs Gauge, wfDs1TotalSESs Gauge, wfDs1TotalSEFs Gauge, wfDs1TotalUASs Gauge, wfDs1TotalBPVs Gauge, wfDs1TotalCVs Gauge } wfDs1TotalIndex OBJECT-TYPE SYNTAX INTEGER(1..1024) ACCESS read-only STATUS mandatory DESCRIPTION "this corresponds to the Wellfleet circuit number" ::= { wfDs1TotalEntry 1 } wfDs1TotalESs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "total count of errored seconds" ::= { wfDs1TotalEntry 2 } wfDs1TotalSESs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "total count of severely errored seconds" ::= { wfDs1TotalEntry 3 } wfDs1TotalSEFs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "total count of severely errored framing seconds" ::= { wfDs1TotalEntry 4 } wfDs1TotalUASs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "total number of unavailable seconds" ::= { wfDs1TotalEntry 5 } wfDs1TotalBPVs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "total count of bipolar violations" ::= { wfDs1TotalEntry 6 } wfDs1TotalCVs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "total count of code violation error events" ::= { wfDs1TotalEntry 7 } wfDs1FeCurrent OBJECT-TYPE SYNTAX SEQUENCE OF WfDs1FeCurrentEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The DS1 Far End Current table" ::= { wfDs1Group 5 } wfDs1FeCurrentEntry OBJECT-TYPE SYNTAX WfDs1FeCurrentEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "per circuit DS1 far end current objects wfDs1CurrentIndex corresponds to Wellfleet circuit number" INDEX { wfDs1FeCurrentIndex } ::= { wfDs1FeCurrent 1 } WfDs1FeCurrentEntry ::= SEQUENCE { wfDs1FeCurrentIndex INTEGER, wfDs1FeCurrentESs Counter, wfDs1FeCurrentSESs Counter, wfDs1FeCurrentSEFs Counter, wfDs1FeCurrentBPVs Counter, wfDs1FeCurrentCVs Counter } wfDs1FeCurrentIndex OBJECT-TYPE SYNTAX INTEGER(1..1024) ACCESS read-only STATUS mandatory DESCRIPTION "this corresponds to the Wellfleet circuit number" ::= { wfDs1FeCurrentEntry 1 } wfDs1FeCurrentESs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "the count of errored seconds in the current interval" ::= { wfDs1FeCurrentEntry 2 } wfDs1FeCurrentSESs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "the count of severely errored seconds in the current interval" ::= { wfDs1FeCurrentEntry 3 } wfDs1FeCurrentSEFs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "the count of severely errored framing seconds in the current interval" ::= { wfDs1FeCurrentEntry 4 } wfDs1FeCurrentBPVs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "the count of bipolar violations in the current interval" ::= { wfDs1FeCurrentEntry 5 } wfDs1FeCurrentCVs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "the count of code violation error events in the current interval" ::= { wfDs1FeCurrentEntry 6 } wfDs1FeInterval OBJECT-TYPE SYNTAX SEQUENCE OF WfDs1FeIntervalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The DS1 Far End Interval table" ::= { wfDs1Group 6 } wfDs1FeIntervalEntry OBJECT-TYPE SYNTAX WfDs1FeIntervalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "per circuit DS1 far end interval objects - wfDs1FeIntervalIndex corresponds to Wellfleet circuit number, wfDs1FeIntervalNumber is the numbered previous 15-minute interval" INDEX { wfDs1FeIntervalIndex, wfDs1FeIntervalNumber } ::= { wfDs1FeInterval 1 } WfDs1FeIntervalEntry ::= SEQUENCE { wfDs1FeIntervalIndex INTEGER, wfDs1FeIntervalNumber INTEGER, wfDs1FeIntervalESs Gauge, wfDs1FeIntervalSESs Gauge, wfDs1FeIntervalSEFs Gauge, wfDs1FeIntervalBPVs Gauge, wfDs1FeIntervalCVs Gauge } wfDs1FeIntervalIndex OBJECT-TYPE SYNTAX INTEGER(1..1024) ACCESS read-only STATUS mandatory DESCRIPTION "this corresponds to the Wellfleet circuit number" ::= { wfDs1FeIntervalEntry 1 } wfDs1FeIntervalNumber OBJECT-TYPE SYNTAX INTEGER(1..96) ACCESS read-only STATUS mandatory DESCRIPTION "1..96 where 1 is the most recent 15-minute interval and 96 is the least" ::= { wfDs1FeIntervalEntry 2 } wfDs1FeIntervalESs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "the count of errored seconds in the specified interval" ::= { wfDs1FeIntervalEntry 3 } wfDs1FeIntervalSESs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "the count of severely errored seconds in the specified interval" ::= { wfDs1FeIntervalEntry 4 } wfDs1FeIntervalSEFs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "the count of severely errored framing seconds in the specified interval" ::= { wfDs1FeIntervalEntry 5 } wfDs1FeIntervalBPVs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "the count of bipolar violations in the specified interval" ::= { wfDs1FeIntervalEntry 6 } wfDs1FeIntervalCVs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "the count of code violation error events in the specified interval" ::= { wfDs1FeIntervalEntry 7 } wfDs1FeTotal OBJECT-TYPE SYNTAX SEQUENCE OF WfDs1FeTotalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The DS1 Far End Total table" ::= { wfDs1Group 7 } wfDs1FeTotalEntry OBJECT-TYPE SYNTAX WfDs1FeTotalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "per circuit DS1 far end total objects - wfDs1FeTotalIndex corresponds to Wellfleet circuit number" INDEX { wfDs1FeTotalIndex } ::= { wfDs1FeTotal 1 } WfDs1FeTotalEntry ::= SEQUENCE { wfDs1FeTotalIndex INTEGER, wfDs1FeTotalESs Gauge, wfDs1FeTotalSESs Gauge, wfDs1FeTotalSEFs Gauge, wfDs1FeTotalBPVs Gauge, wfDs1FeTotalCVs Gauge } wfDs1FeTotalIndex OBJECT-TYPE SYNTAX INTEGER(1..1024) ACCESS read-only STATUS mandatory DESCRIPTION "this corresponds to the Wellfleet circuit number" ::= { wfDs1FeTotalEntry 1 } wfDs1FeTotalESs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "total count of errored seconds" ::= { wfDs1FeTotalEntry 2 } wfDs1FeTotalSESs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "total count of severely errored seconds" ::= { wfDs1FeTotalEntry 3 } wfDs1FeTotalSEFs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "total count of severely errored framing seconds" ::= { wfDs1FeTotalEntry 4 } wfDs1FeTotalBPVs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "total count of bipolar violations" ::= { wfDs1FeTotalEntry 5 } wfDs1FeTotalCVs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "total count of code violation error events" ::= { wfDs1FeTotalEntry 6 } END -- Wellfleet-DS1-MIB