-- Version 2.15.1.6, modified 2002-01-10 09:18:45-05 VOICE-OPT-MIB DEFINITIONS ::= BEGIN IMPORTS Counter, Gauge, enterprises FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212; -- Codex MIB Group definitions codex OBJECT IDENTIFIER ::= { enterprises 449 } cdxProductSpecific OBJECT IDENTIFIER ::= { codex 2 } cdx6500 OBJECT IDENTIFIER ::= { cdxProductSpecific 1 } cdx6500Configuration OBJECT IDENTIFIER ::= { cdx6500 2 } cdx6500CfgProtocolGroup OBJECT IDENTIFIER ::= { cdx6500Configuration 1 } cdx6500PCTPortProtocolGroup OBJECT IDENTIFIER ::= { cdx6500CfgProtocolGroup 1 } cdx6500CfgGeneralGroup OBJECT IDENTIFIER ::= { cdx6500Configuration 2 } cdx6500Statistics OBJECT IDENTIFIER ::= { cdx6500 3 } cdx6500StatProtocolGroup OBJECT IDENTIFIER ::= { cdx6500Statistics 1 } cdx6500PSTPortProtocolGroup OBJECT IDENTIFIER ::= { cdx6500StatProtocolGroup 1 } cdx6500StatNetworkSvcsGroup OBJECT IDENTIFIER ::= { cdx6500Statistics 4 } cdx6500Controls OBJECT IDENTIFIER ::= { cdx6500 4 } -- Textual Conventions DisplayString ::= OCTET STRING PhysicalPortNumber ::= INTEGER (1..54) cdx6500PCTVoicePortTable OBJECT IDENTIFIER ::= { cdx6500PCTPortProtocolGroup 25 } cdx6500PSTVoicePortTable OBJECT IDENTIFIER ::= { cdx6500PSTPortProtocolGroup 26 } cdx6500GCTVoiceSwitchTable OBJECT IDENTIFIER ::= { cdx6500CfgGeneralGroup 21 } -- Voice Port Configuration Table cdx6500PPCTVoicePortTable OBJECT-TYPE SYNTAX SEQUENCE OF Cdx6500PPCTVoicePortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the port configuration parameters to configure the DSPM/E&M, DSPM/FXS, DSPM/HC, and DSPM/SM." ::= { cdx6500PCTVoicePortTable 1 } cdx6500PPCTVoicePortEntry OBJECT-TYPE SYNTAX Cdx6500PPCTVoicePortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A Voice Port Configuration Table Entry. Each entry contains the configuration parameters for a single Voice Port." INDEX { cdx6500VoiceCfgPortNumber } ::= { cdx6500PPCTVoicePortTable 1 } Cdx6500PPCTVoicePortEntry ::= SEQUENCE { cdx6500VoiceCfgPortNumber INTEGER, cdx6500VoiceCfgPortType INTEGER, cdx6500VoiceCfgInterfaceType INTEGER, cdx6500VoiceCfgSignalingType INTEGER, cdx6500VoiceCfgELeadFilter INTEGER, cdx6500VoiceCfgHybridFXS INTEGER, cdx6500VoiceCfgHybridEAndM2 INTEGER, cdx6500VoiceCfgSignalingMode INTEGER, cdx6500VoiceCfgSignalingControl INTEGER, cdx6500VoiceCfgNoOfDigitsToCollect INTEGER, cdx6500VoiceCfgNoOfRings INTEGER, cdx6500VoiceCfgPCMMode INTEGER, cdx6500VoiceCfgCompressionRate INTEGER, cdx6500VoiceCfgDSIControl INTEGER, cdx6500VoiceCfgSmoothingDelay INTEGER, cdx6500VoiceCfgEchoControl INTEGER, cdx6500VoiceCfgEchoReturnLoss INTEGER, cdx6500VoiceCfgTxInputSignalLevel DisplayString, cdx6500VoiceCfgRxOutputSignalLevel DisplayString, cdx6500VoiceCfgFaxSupport INTEGER, cdx6500VoiceCfgFaxRates INTEGER, cdx6500VoiceCfgVoiceBandDetection INTEGER, cdx6500VoiceCfgAutoCallMnemonic DisplayString, cdx6500VoiceCfgCallControl INTEGER, cdx6500VoiceCfgAutoCallTimeout INTEGER, cdx6500VoiceCfgCallRetries INTEGER, cdx6500VoiceCfgGroupSubaddress INTEGER, cdx6500VoiceCfgBilling INTEGER, cdx6500VoiceCfgRxSignalingStateChangeFilter INTEGER, cdx6500VoiceCfgT1E1RxIdleOnhookState DisplayString, cdx6500VoiceCfgT1E1TxIdleOnhookState DisplayString, cdx6500VoiceCfgT1E1RxActiveOffhookState DisplayString, cdx6500VoiceCfgT1E1TxActiveOffhookState DisplayString, cdx6500VoiceCfgT1E1RingingState DisplayString, cdx6500VoiceCfgT1E1NoRingingState DisplayString, cdx6500VoiceCfgRxWinkStartTimer INTEGER, cdx6500VoiceCfgRxMinimumReceiveWink INTEGER, cdx6500VoiceCfgRxCalledEndGlareDetect INTEGER, cdx6500VoiceCfgRxFirstDigitTimer INTEGER, cdx6500VoiceCfgRxInterdigitTimer INTEGER, cdx6500VoiceCfgTxWinkDelay INTEGER, cdx6500VoiceCfgTxWinkWidth INTEGER, cdx6500VoiceCfgTxDigitDelay INTEGER, cdx6500VoiceCfgTxDigitOn INTEGER, cdx6500VoiceCfgTxInterdigitTime INTEGER, cdx6500VoiceCfgRxInterringWait INTEGER, cdx6500VoiceCfgRxRingStateChangeFilter INTEGER, cdx6500VoiceCfgTxRingerOffLong INTEGER, cdx6500VoiceCfgTxRingerOffShort INTEGER, cdx6500VoiceCfgTxRingerOn INTEGER, cdx6500VoiceCfgRxDisconnectTimer INTEGER, cdx6500VoiceCfgRxCalledEndDisconnectDelayTimer INTEGER, cdx6500VoiceCfgLineErrorRecovery INTEGER, cdx6500VoiceCfgSignalingSampleRate INTEGER, cdx6500VoiceCfgWaitForParams INTEGER, cdx6500VoiceCfgSpareTimer1 INTEGER, cdx6500VoiceCfgSpareTimer2 INTEGER, cdx6500VoiceCfgTxInterdigitPauseTime INTEGER, cdx6500VoiceCfgRxMinimumFlashHookTime INTEGER, cdx6500VoiceCfgRxMaximumFlashHookTime INTEGER, cdx6500VoiceCfgTransparentSignalingIdleState DisplayString, cdx6500VoiceCfgTransparentRxDisconnectFilter INTEGER, cdx6500VoiceCfgTransparentSignalingBusyoutState DisplayString, cdx6500VoiceCfgXlateSigInfo0000FromRemoteToLocalPort DisplayString, cdx6500VoiceCfgXlateSigInfo1000FromRemoteToLocalPort DisplayString, cdx6500VoiceCfgXlateSigInfo0100FromRemoteToLocalPort DisplayString, cdx6500VoiceCfgXlateSigInfo1100FromRemoteToLocalPort DisplayString, cdx6500VoiceCfgXlateSigInfo0010FromRemoteToLocalPort DisplayString, cdx6500VoiceCfgXlateSigInfo1010FromRemoteToLocalPort DisplayString, cdx6500VoiceCfgXlateSigInfo0110FromRemoteToLocalPort DisplayString, cdx6500VoiceCfgXlateSigInfo1110FromRemoteToLocalPort DisplayString, cdx6500VoiceCfgXlateSigInfo0001FromRemoteToLocalPort DisplayString, cdx6500VoiceCfgXlateSigInfo1001FromRemoteToLocalPort DisplayString, cdx6500VoiceCfgXlateSigInfo0101FromRemoteToLocalPort DisplayString, cdx6500VoiceCfgXlateSigInfo1101FromRemoteToLocalPort DisplayString, cdx6500VoiceCfgXlateSigInfo0011FromRemoteToLocalPort DisplayString, cdx6500VoiceCfgXlateSigInfo1011FromRemoteToLocalPort DisplayString, cdx6500VoiceCfgXlateSigInfo0111FromRemoteToLocalPort DisplayString, cdx6500VoiceCfgXlateSigInfo1111FromRemoteToLocalPort DisplayString, cdx6500VoiceCfgDialToneLowerFrequency INTEGER, cdx6500VoiceCfgDialToneLowerFrequencyAmplitude DisplayString, cdx6500VoiceCfgDialToneUpperFrequency INTEGER, cdx6500VoiceCfgDialToneUpperFrequencyAmplitude DisplayString, cdx6500VoiceCfgRingBackToneLowerFrequency INTEGER, cdx6500VoiceCfgRingBackToneLowerFrequencyAmplitude DisplayString, cdx6500VoiceCfgRingBackToneUpperFrequency INTEGER, cdx6500VoiceCfgRingBackToneUpperFrequencyAmplitude DisplayString, cdx6500VoiceCfgBusyToneLowerFrequency INTEGER, cdx6500VoiceCfgBusyToneLowerFrequencyAmplitude DisplayString, cdx6500VoiceCfgBusyToneUpperFrequency INTEGER, cdx6500VoiceCfgBusyToneUpperFrequencyAmplitude DisplayString, cdx6500VoiceCfgTxBusyToneOffTime INTEGER, cdx6500VoiceCfgTxBusyToneOnTime INTEGER, cdx6500VoiceCfgFastBusyToneLowerFrequency INTEGER, cdx6500VoiceCfgFastBusyToneLowerFrequencyAmplitude DisplayString, cdx6500VoiceCfgFastBusyToneUpperFrequency INTEGER, cdx6500VoiceCfgFastBusyToneUpperFrequencyAmplitude DisplayString, cdx6500VoiceCfgTxFastBusyToneOffTime INTEGER, cdx6500VoiceCfgTxFastBusyToneOnTime INTEGER, cdx6500VoiceCfgHybridFXO INTEGER, cdx6500VoiceCfgTxPulse INTEGER, cdx6500VoiceCfgRxMinPulse INTEGER, cdx6500VoiceCfgRxMaxPulse INTEGER, cdx6500VoiceCfgTxMasterClear INTEGER, cdx6500VoiceCfgRxMinMasterClear INTEGER, cdx6500VoiceCfgRxMaxMasterClear INTEGER, cdx6500VoiceCfgTxSlaveClear INTEGER, cdx6500VoiceCfgRxMinSlaveClear INTEGER, cdx6500VoiceCfgRxMaxSlaveClear INTEGER, cdx6500VoiceCfgTxSlaveRelease INTEGER, cdx6500VoiceCfgRxMinSlaveRelease INTEGER, cdx6500VoiceCfgRxMaxSlaveRelease INTEGER, cdx6500VoiceCfgTxPTSTime INTEGER, cdx6500VoiceCfgRxPTSTime INTEGER, cdx6500VoiceCfgMasterGuard INTEGER, cdx6500VoiceCfgSlaveGuard INTEGER, cdx6500VoiceCfgTxFlashHookTime INTEGER, cdx6500VoiceCfgDtmfAmplitude DisplayString, cdx6500VoiceCfgFXSOffhookFilter INTEGER } cdx6500VoiceCfgPortNumber OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "Port number of the Voice port." ::= { cdx6500PPCTVoicePortEntry 1 } cdx6500VoiceCfgPortType OBJECT-TYPE SYNTAX INTEGER { voice (43) } ACCESS read-only STATUS mandatory DESCRIPTION "This parameter represents the port type of the port. voice :This is a voice port." ::= { cdx6500PPCTVoicePortEntry 2 } cdx6500VoiceCfgInterfaceType OBJECT-TYPE SYNTAX INTEGER { eAndM2 (1), eAndM4 (2), fxo (3), fxs (4), nc (100) } ACCESS read-only STATUS mandatory DESCRIPTION "Select one of the following physical interfaces being used for this port. The entry must match the hardware. eAndM2 :2 wire E&M (Ear and Mouth) Interface. eAndM4 :4 wire E&M (Ear and Mouth) Interface. fxo :FXO (Foreign Exchange Office ) Interface. fxs :FXS (Foreign Exchange Station) Interface. nc :Skipped during configuration. eAndM2 is only displayed for port numbers 1..54." ::= { cdx6500PPCTVoicePortEntry 3 } cdx6500VoiceCfgSignalingType OBJECT-TYPE SYNTAX INTEGER { i (1), ii (2), v (3), iii (4), nc (100) } ACCESS read-only STATUS mandatory DESCRIPTION "Select the E&M signalling type. i : EandMTypeI. ii : EandMTypeII. v : EandMTypeV. iii : EandMTypeIII. nc : Skipped during configuration. This parameter is displayed for DSPM/E&M and skipped for FXS, FXO, and all virtual port types." ::= { cdx6500PPCTVoicePortEntry 4 } cdx6500VoiceCfgELeadFilter OBJECT-TYPE SYNTAX INTEGER { disabled (1), enabled (2), nc (100) } ACCESS read-only STATUS mandatory DESCRIPTION "Selection for E lead filter enable or disable option. disabled : Disables E-lead filter. enabled : Enables E-lead filter. nc : Skipped during configuration. This parameter is displayed for DSPM/E&M and skipped for FXS, FXO, and all virtual port types." ::= { cdx6500PPCTVoicePortEntry 5 } cdx6500VoiceCfgHybridFXS OBJECT-TYPE SYNTAX INTEGER { sixHundred (1), canada (2), germany (3), uk (5), belgium (8), france (9), nc (100) } ACCESS read-only STATUS mandatory DESCRIPTION "Hybrid balance filters and termination type based on country. sixHundred : 600 ohm interface for USA, Japan and Ireland. canada : 600 ohms with 2.16 uF germany : 220 ohms in series with (820 ohms in parallel with 115nF). uk : 300 ohms in series with (1K ohms in parallel with 220nF). belgium : 150 ohms in series with (830 ohms in parallel with 72nF). france : 215 ohms in series with (1K ohms in parallel with 137nF). nc : Skipped during configuration. This parameter is displayed for DSPM/FXS and skipped for DSPM/E&M, DSPM/HC(FXO) and all virtual port types." ::= { cdx6500PPCTVoicePortEntry 6 } cdx6500VoiceCfgHybridEAndM2 OBJECT-TYPE SYNTAX INTEGER { sixHundred (1), germany (3), uk (10), nc (100) } ACCESS read-only STATUS mandatory DESCRIPTION "Hybrid balance filters and termination type based on country. (Only for E&M-2wire interfaces.) sixHundred : 600 ohm interface for USA, Japan and Ireland. germany : 220 ohms in series with (820 ohms in parallel with 115nF). uk : 370 ohms in series with (620 ohms in parallel with 310nF). nc : Skipped during configuration." ::= { cdx6500PPCTVoicePortEntry 7 } cdx6500VoiceCfgSignalingMode OBJECT-TYPE SYNTAX INTEGER { normal (1), none (2), nc (100) } ACCESS read-only STATUS mandatory DESCRIPTION "Select the voice signalling mode. normal : Allows signalling to pass end to end and signalling will be used to control circuit state and packet flow. none : A permanent voice path is established and packet flow is always enabled, but no signalling will be passed through. nc : Skipped during configuration." ::= { cdx6500PPCTVoicePortEntry 8 } cdx6500VoiceCfgSignalingControl OBJECT-TYPE SYNTAX INTEGER { immediate (1), wink (2), transparent (3), delay (4), masterColisee (5), slaveColisee (6), seizureAcknowledge (7), nc (100) } ACCESS read-only STATUS mandatory DESCRIPTION "Select signaling control transmission mode in E&M interface type. immediate : Digits are transmitted immediately. wink : Digits are transmitted after the WINK pulse. transparent : The voice signalling states are transmitted end to end without interpreting the signalling state. delay : Digits are transmitted after the end of the Delay Dial signal. masterColisee : 65xx is simulating Colisee master mode. slaveColisee : 65xx is simulating Colisee slave mode. seizureAcknowledge : Transmit Seizure acknowledge immediately after receiving a Seizure signal from the PBX. nc : Skipped during configuration. The parameter will be skipped for FXO & FXS type interface." ::= { cdx6500PPCTVoicePortEntry 9 } cdx6500VoiceCfgNoOfDigitsToCollect OBJECT-TYPE SYNTAX INTEGER (0..11) ACCESS read-only STATUS deprecated DESCRIPTION "Select number of digits to collect before making a call. The parameter will not be supported." ::= { cdx6500PPCTVoicePortEntry 10 } cdx6500VoiceCfgNoOfRings OBJECT-TYPE SYNTAX INTEGER (0..9) ACCESS read-only STATUS mandatory DESCRIPTION "Number of rings to be received before a call can be accepted. This parameter is displayed for FXO and skipped for E&M and FXS interface types. A value of 0 implies that this parameter was skipped during configuration." ::= { cdx6500PPCTVoicePortEntry 11 } cdx6500VoiceCfgPCMMode OBJECT-TYPE SYNTAX INTEGER { aLaw (1), muLaw (2), nc (100) } ACCESS read-only STATUS mandatory DESCRIPTION "Select the PCM encoder/decoder mode. aLaw :PCM encoder/decoder mode = A Law. muLaw :PCM encoder/decoder mode = Mu Law. nc :Skipped during configuration." ::= { cdx6500PPCTVoicePortEntry 12 } cdx6500VoiceCfgCompressionRate OBJECT-TYPE SYNTAX INTEGER { cD8K (1), cD16K (2), cBD8K (3), cBD16K (4), cE8Kb (12), cE16Kb (13), nc (100) } ACCESS read-only STATUS mandatory DESCRIPTION "Select the voice compression rate to be used by the DSP. cD8K : 8k CVSELP c16k : 16k CVSELP cBD8K : Bundled 8k CVSELP cB16k : Bundled 16k CVSELP. cE8Kb : Enhanced Bundled 8k CVSELP cE16Kb : Enhanced Bundled 16k CVSELP nc : Skipped during configuration." ::= { cdx6500PPCTVoicePortEntry 13 } cdx6500VoiceCfgDSIControl OBJECT-TYPE SYNTAX INTEGER { disabled (1), enabled (2), nc (100) } ACCESS read-only STATUS mandatory DESCRIPTION "Select if the Digital Speech Interpolation (Silence Detector) will be used with this channel. enabled : DSI is activated. disabled : DSI is not used. nc : Skipped during configuration." ::= { cdx6500PPCTVoicePortEntry 14 } cdx6500VoiceCfgSmoothingDelay OBJECT-TYPE SYNTAX INTEGER (5..150) ACCESS read-only STATUS mandatory DESCRIPTION "Select maximum inter packet arrival jitter due to network in milliseconds." ::= { cdx6500PPCTVoicePortEntry 15 } cdx6500VoiceCfgEchoControl OBJECT-TYPE SYNTAX INTEGER { disabled (1), enabled (2), nc (100) } ACCESS read-only STATUS mandatory DESCRIPTION "Select echo control. disabled : Echo pass through. enabled : This enables echo control logic. nc : Skipped during configuration. Echo not detected and not cancelled. This parameter will be skipped in normal mode and only displayed when DEBUG is turned on." ::= { cdx6500PPCTVoicePortEntry 16 } cdx6500VoiceCfgEchoReturnLoss OBJECT-TYPE SYNTAX INTEGER { minus3 (2), minus6 (3), minus9 (4), minus12 (5), nc (100) } ACCESS read-only STATUS mandatory DESCRIPTION "Select echo return loss in dBm. minus3 : -3 dBm. minus6 : -6 dBm. minus9 : -9 dBm. minus12 : -12dBm. nc :Skipped during configuration." ::= { cdx6500PPCTVoicePortEntry 17 } cdx6500VoiceCfgTxInputSignalLevel OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Enter the input signal level. To be specified in steps of 0.5 dBm FXO Interface Type : 600 Ohms +6.0 to -2.5dbm 600 Ohms Adaptive +6.0 to -2.5dbm FXS Interface Type : 600 Ohms +6.0 to -6.0dbm Canada +6.0 to -5.5dbm UK +4.5 to -7.5dbm Germany +4.0 to -8.0dbm France -2.0 to -9.0dbm Belgium +4.0 to -8.0dbm E&M Interface Type : 4-Wire/600 +7.0 to -16.0dbm 2-Wire/600 +7.0 to -16.0dbm 2-Wire/UK +5.0 to -16.0dbm 2-Wire/Germany +5.0 to -16.0dbm Virtual Ports(100 and above): +8.0 to -6.0dbm Entering a negative number for the 'Input Signal Level' will result in the DSPM card amplifying the signal by that many dB. Entering a positive number for the 'Input Signal Level' will result in the DSPM card attenuating the signal by that many dB." ::= { cdx6500PPCTVoicePortEntry 18 } cdx6500VoiceCfgRxOutputSignalLevel OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Enter the output signal level. To be selected in steps of 0.5 dBm. FXO Interface Type : 600 Ohms +0.0 to -8.0dbm 600 Ohms Adaptive +0.0 to -8.0dbm FXS Interface Type : 600 Ohms +0.0 to -9.0dbm Canada +0.0 to -9.0dbm UK -1.5 to -9.0dbm Germany -2.0 to -9.0dbm France -1.5 to -9.0dbm Belgium -1.5 to -9.0dbm E&M Interface Type : 4-Wire/600 +7.0 to -16.0dbm 2-Wire/600 +3.0 to -16.0dbm 2-Wire/UK +1.0 to -16.0dbm 2-Wire/Germany +0.0 to -16.0dbm Virtual Ports(100 and above): +6.0 to -8.0dbm Entering a negative number for the 'Output Signal Level' will result in the DSPM card attenuating the signal by that many dB. Entering a positive number for the 'Output Signal Level' will result in the DSPM card amplifying the signal by that many dB." ::= { cdx6500PPCTVoicePortEntry 19 } cdx6500VoiceCfgFaxSupport OBJECT-TYPE SYNTAX INTEGER { disabled (1), enabled (2), nc (100) } ACCESS read-only STATUS mandatory DESCRIPTION "This parameter selects whether the FAX data is to be supported. disabled : FAX data will not be detected. enabled : Detects presence of FAX data. nc : Skipped during configuration." ::= { cdx6500PPCTVoicePortEntry 20 } cdx6500VoiceCfgFaxRates OBJECT-TYPE SYNTAX INTEGER { fr9600 (1), fr4800 (2), nc (100) } ACCESS read-only STATUS mandatory DESCRIPTION "Specify the speed to switch to, when FAX data is detected. This parameter is ignored if Fax support was disabled. fr9600 : FAX to be transmitted across the network at 9600 bits per second. fr4800 : FAX to be transmitted across the network at 4800 bits per second. nc : Skipped during configuration." ::= { cdx6500PPCTVoicePortEntry 21 } cdx6500VoiceCfgVoiceBandDetection OBJECT-TYPE SYNTAX INTEGER { yes (1), no (2), nc (100) } ACCESS read-only STATUS mandatory DESCRIPTION "Modem data detection. yes : Detection of modem data enabled. no : Detection of modem data disabled. nc : Skipped during configuration. This parameter will be skipped in normal mode.Displayed only when DEBUG is turned on." ::= { cdx6500PPCTVoicePortEntry 22 } cdx6500VoiceCfgAutoCallMnemonic OBJECT-TYPE SYNTAX DisplayString (SIZE (0..8)) ACCESS read-only STATUS mandatory DESCRIPTION "This mnemonic name is used to originate the call. It consists of 0 - 8 alphanumeric characters." ::= { cdx6500PPCTVoicePortEntry 23 } cdx6500VoiceCfgCallControl OBJECT-TYPE SYNTAX INTEGER { offhook (1), auto (2), switched (3), nc (100) } ACCESS read-only STATUS mandatory DESCRIPTION "Select calling method. offhook : Call only when Offhook.Disconnect on Onhook. auto : SVC does not depend on On/Offhook condition.It remains established permanently after the power-up. switched : Call only when interface goes offhook and disconnect call when interface goes onhook. Destination is determined by the DTMF digits received. nc : Skipped during configuration." ::= { cdx6500PPCTVoicePortEntry 24 } cdx6500VoiceCfgAutoCallTimeout OBJECT-TYPE SYNTAX INTEGER (5..255) ACCESS read-only STATUS mandatory DESCRIPTION "Time interval between two successive calls in case of failure of previous call.Used only in `Auto' call control mode.This parameter will be skipped if Call Control is Offhook and Switched." ::= { cdx6500PPCTVoicePortEntry 25 } cdx6500VoiceCfgCallRetries OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "Enter maximum number of call retries when previous call failed.Used only in Auto Call Control mode.'0' means try forever. This parameter will be skipped if Call Control is Offhook and Switched." ::= { cdx6500PPCTVoicePortEntry 26 } cdx6500VoiceCfgGroupSubaddress OBJECT-TYPE SYNTAX INTEGER (0..999) ACCESS read-only STATUS mandatory DESCRIPTION "Specifies a port subaddress that is shared by several Voice ports. Incoming calls with this subaddress are routed to one of several ports sharing this subaddress. Another name for the group of ports with the same Group Subaddress is Hunt Group." ::= { cdx6500PPCTVoicePortEntry 27 } cdx6500VoiceCfgBilling OBJECT-TYPE SYNTAX INTEGER { disabled (1), enabled (2), nc (100) } ACCESS read-only STATUS mandatory DESCRIPTION "This controls whether billing (accounting) records will be created for calls on this port. enabled : Billing is enabled. disabled : Billing is disabled. nc : Skipped during configuration." ::= { cdx6500PPCTVoicePortEntry 28 } cdx6500VoiceCfgRxSignalingStateChangeFilter OBJECT-TYPE SYNTAX INTEGER (0..1000) ACCESS read-only STATUS mandatory DESCRIPTION "The amount of time to declare a valid supervisory signaling state change. The granularity is 10 milliseconds." ::= { cdx6500PPCTVoicePortEntry 29 } cdx6500VoiceCfgT1E1RxIdleOnhookState OBJECT-TYPE SYNTAX DisplayString (SIZE (4)) ACCESS read-only STATUS mandatory DESCRIPTION "The signalling state that represents the idle state. For E1 ports and T1 ESF ports, these bits represent the ABCD signalling bits on the interface. For T1 SF ports these bits represent ABAB signalling bits. `x' means don't care.The range is from 0000 to 1111." ::= { cdx6500PPCTVoicePortEntry 30 } cdx6500VoiceCfgT1E1TxIdleOnhookState OBJECT-TYPE SYNTAX DisplayString (SIZE (4)) ACCESS read-only STATUS mandatory DESCRIPTION "The signalling state that represents the idle state. For E1 ports and T1 ESF ports, these bits represent the ABCD signalling bits on the interface. For T1 SF ports these bits represent ABAB signalling bits. The range is from 0000 to 1111." ::= { cdx6500PPCTVoicePortEntry 31 } cdx6500VoiceCfgT1E1RxActiveOffhookState OBJECT-TYPE SYNTAX DisplayString (SIZE (4)) ACCESS read-only STATUS mandatory DESCRIPTION "The signalling state that represents the active state. For E1 ports and T1 ESF ports, these bits represent the ABCD signalling bits on the interface. For T1 SF ports these bits represent ABAB signalling bits. ` x' means don't care. The range is from 0000 to 1111." ::= { cdx6500PPCTVoicePortEntry 32 } cdx6500VoiceCfgT1E1TxActiveOffhookState OBJECT-TYPE SYNTAX DisplayString (SIZE (4)) ACCESS read-only STATUS mandatory DESCRIPTION "The signalling state that represents the active state. For E1 ports and T1 ESF ports, these bits represent the ABCD signalling bits on the interface. The range is from 0000 to 1111." ::= { cdx6500PPCTVoicePortEntry 33 } cdx6500VoiceCfgT1E1RingingState OBJECT-TYPE SYNTAX DisplayString (SIZE (4)) ACCESS read-only STATUS mandatory DESCRIPTION "The signalling state that represents the ringing state. For E1 ports and T1 ESF ports, these bits represent the ABCD signalling bits on the interface. For T1 SF ports these bits represent ABAB signalling bits. `x' means don't care. The range is from 0000 to 1111." ::= { cdx6500PPCTVoicePortEntry 34 } cdx6500VoiceCfgT1E1NoRingingState OBJECT-TYPE SYNTAX DisplayString (SIZE (4)) ACCESS read-only STATUS mandatory DESCRIPTION "The signalling state that represents the no ringing state. For E1 ports and T1 ESF ports, these bits represent the ABCD signalling bits on the interface. For T1 SF ports these bits represent ABAB signalling bits. `x' means don't care. The range is from 0000 to 1111." ::= { cdx6500PPCTVoicePortEntry 35 } cdx6500VoiceCfgRxWinkStartTimer OBJECT-TYPE SYNTAX INTEGER (0..2000) ACCESS read-only STATUS mandatory DESCRIPTION "This is the maximum time to wait for the beginning of the wink signal from the PBX before declaring a wink start malfunction. Granularity is 50 milliseconds." ::= { cdx6500PPCTVoicePortEntry 36 } cdx6500VoiceCfgRxMinimumReceiveWink OBJECT-TYPE SYNTAX INTEGER (10..2000) ACCESS read-only STATUS mandatory DESCRIPTION "The amount of time required to declare a valid wink. Granularity is 10 milliseconds." ::= { cdx6500PPCTVoicePortEntry 37 } cdx6500VoiceCfgRxCalledEndGlareDetect OBJECT-TYPE SYNTAX INTEGER (50..10000) ACCESS read-only STATUS mandatory DESCRIPTION "The length of time when a wink pulse will be detected as a glare condition. Granularity is 50 milliseconds." ::= { cdx6500PPCTVoicePortEntry 38 } cdx6500VoiceCfgRxFirstDigitTimer OBJECT-TYPE SYNTAX INTEGER (1..60) ACCESS read-only STATUS mandatory DESCRIPTION "The maximum time (in seconds) to wait for the first DTMF digit before declaring a `busyout' state. Granularity is 1 second." ::= { cdx6500PPCTVoicePortEntry 39 } cdx6500VoiceCfgRxInterdigitTimer OBJECT-TYPE SYNTAX INTEGER (1..60) ACCESS read-only STATUS mandatory DESCRIPTION "This is the maximum time (in seconds) to wait for a subsequent receive digit before declaring a misdial. Granularity is 1 second." ::= { cdx6500PPCTVoicePortEntry 40 } cdx6500VoiceCfgTxWinkDelay OBJECT-TYPE SYNTAX INTEGER (10..1000) ACCESS read-only STATUS mandatory DESCRIPTION "The time delay from receiving a valid Offhook state to start transmitting a wink. Granularity is 10 milliseconds." ::= { cdx6500PPCTVoicePortEntry 41 } cdx6500VoiceCfgTxWinkWidth OBJECT-TYPE SYNTAX INTEGER (10..2000) ACCESS read-only STATUS mandatory DESCRIPTION "The width of the transmitted wink pulse. Granularity is 10 milliseconds." ::= { cdx6500PPCTVoicePortEntry 42 } cdx6500VoiceCfgTxDigitDelay OBJECT-TYPE SYNTAX INTEGER (0..5000) ACCESS read-only STATUS mandatory DESCRIPTION "The time delay before transmitting the first DTMF digit after a wink is received.Granularity is 10 milliseconds." ::= { cdx6500PPCTVoicePortEntry 43 } cdx6500VoiceCfgTxDigitOn OBJECT-TYPE SYNTAX INTEGER (60..1000) ACCESS read-only STATUS mandatory DESCRIPTION "The time DTMF digits are transmitted. Granularity is 10 milliseconds." ::= { cdx6500PPCTVoicePortEntry 44 } cdx6500VoiceCfgTxInterdigitTime OBJECT-TYPE SYNTAX INTEGER (60..1000) ACCESS read-only STATUS mandatory DESCRIPTION "The time between transmitting DTMF digits. Granularity is 10 milliseconds." ::= { cdx6500PPCTVoicePortEntry 45 } cdx6500VoiceCfgRxInterringWait OBJECT-TYPE SYNTAX INTEGER (1..60) ACCESS read-only STATUS mandatory DESCRIPTION "This is the maximum time to wait for subsequent receive rings before declaring a call abandoned condition. Granularity is 1 second." ::= { cdx6500PPCTVoicePortEntry 46 } cdx6500VoiceCfgRxRingStateChangeFilter OBJECT-TYPE SYNTAX INTEGER (0..2000) ACCESS read-only STATUS mandatory DESCRIPTION "The amount of time to declare the change in the ring state. Granularity is 50 milliseconds." ::= { cdx6500PPCTVoicePortEntry 47 } cdx6500VoiceCfgTxRingerOffLong OBJECT-TYPE SYNTAX INTEGER (100..10000) ACCESS read-only STATUS mandatory DESCRIPTION "This timer is the long off period for ringer cadences that have a short and long off period.For the cases where the ring cadence defines one off period, the Tx Ringer Off Long must be equal to Tx Ringer Off Short. Granularity is 50 milliseconds." ::= { cdx6500PPCTVoicePortEntry 48 } cdx6500VoiceCfgTxRingerOffShort OBJECT-TYPE SYNTAX INTEGER (100..10000) ACCESS read-only STATUS mandatory DESCRIPTION "This timer is the short off period for ringer cadences that have a short and long off period.For the cases where the ring cadence defines one off period, the Tx Ringer Off Long must be equal to Tx Ringer Off Short. Granularity is 50 milliseconds." ::= { cdx6500PPCTVoicePortEntry 49 } cdx6500VoiceCfgTxRingerOn OBJECT-TYPE SYNTAX INTEGER (100..10000) ACCESS read-only STATUS mandatory DESCRIPTION "The time of the ringer on pulse. Granularity is 50 milliseconds." ::= { cdx6500PPCTVoicePortEntry 50 } cdx6500VoiceCfgRxDisconnectTimer OBJECT-TYPE SYNTAX INTEGER (200..30000) ACCESS read-only STATUS mandatory DESCRIPTION "The amount of time required to receive idle signaling to disconnect a call. For an analog FXO port, RX idle signaling is the loss of loop current. For a FXS port, RX idle signaling is when the interface goes onhook. For an analog E&M port, RX idle signaling is when the 'M' lead goes idle. For digital interfaces, the RX idle state is defined by the 'T1/E1 Rx Idle (on-hook) State' parameter." ::= { cdx6500PPCTVoicePortEntry 51 } cdx6500VoiceCfgRxCalledEndDisconnectDelayTimer OBJECT-TYPE SYNTAX INTEGER (0..20) ACCESS read-only STATUS mandatory DESCRIPTION "The additional amount of time beyond the Rx Disconnect filter the calling end must be Onhook to disconnect a call. Granularity is 1 second." ::= { cdx6500PPCTVoicePortEntry 52 } cdx6500VoiceCfgLineErrorRecovery OBJECT-TYPE SYNTAX INTEGER (0..1000) ACCESS read-only STATUS mandatory DESCRIPTION "The length of time voice will be suppressed after LOS or OF condition clears.Granularity is 10 milliseconds. This parameter will be displayed for virtual ports only." ::= { cdx6500PPCTVoicePortEntry 53 } cdx6500VoiceCfgSignalingSampleRate OBJECT-TYPE SYNTAX INTEGER (1..20) ACCESS read-only STATUS mandatory DESCRIPTION "The time between sampling received signalling states and line states.Granularity is 1 millisecond. This parameter will be displayed only when the DEBUG flag is set." ::= { cdx6500PPCTVoicePortEntry 54 } cdx6500VoiceCfgWaitForParams OBJECT-TYPE SYNTAX INTEGER (0..10) ACCESS read-only STATUS mandatory DESCRIPTION "The amount of time to wait for a message to set the parameters after receiving a disconnect message (messages occur in the form of an event) before busying out the port. Granularity is 1 second. This parameter will be displayed only when the DEBUG flag is set." ::= { cdx6500PPCTVoicePortEntry 55 } cdx6500VoiceCfgSpareTimer1 OBJECT-TYPE SYNTAX INTEGER (1..10000) ACCESS read-only STATUS mandatory DESCRIPTION "Spare timer number 1.Granularity is 1 millisecond.This parameter will be displayed only when the DEBUG flag is set." ::= { cdx6500PPCTVoicePortEntry 56 } cdx6500VoiceCfgSpareTimer2 OBJECT-TYPE SYNTAX INTEGER (1..10000) ACCESS read-only STATUS mandatory DESCRIPTION "Spare timer number 2.Granularity is 1 millisecond. This parameter will be displayed only when the DEBUG flag is set." ::= { cdx6500PPCTVoicePortEntry 57 } cdx6500VoiceCfgTxInterdigitPauseTime OBJECT-TYPE SYNTAX INTEGER (1..10000) ACCESS read-only STATUS mandatory DESCRIPTION "The time between transmitting DTMF digits. Enter in steps of 10 msec. " ::= { cdx6500PPCTVoicePortEntry 58 } cdx6500VoiceCfgRxMinimumFlashHookTime OBJECT-TYPE SYNTAX INTEGER (100..10000) ACCESS read-only STATUS mandatory DESCRIPTION "The shortest length of time required to be onhook to be recognized as a flash-hook. This value must be less than Rx Maximum Flash-Hook Time for flash-hook to be recognized." ::= { cdx6500PPCTVoicePortEntry 59 } cdx6500VoiceCfgRxMaximumFlashHookTime OBJECT-TYPE SYNTAX INTEGER (100..10000) ACCESS read-only STATUS mandatory DESCRIPTION "The longest length of time to be onhook to be recognized as a flash-hook. This value must be less than Rx Disconnect Timer for flash-hook to be recognized. Note: the average of the minimum and maximum flash-hook values will be the pulse width for a transmitted flash-hook." ::= { cdx6500PPCTVoicePortEntry 60 } cdx6500VoiceCfgTransparentSignalingIdleState OBJECT-TYPE SYNTAX DisplayString (SIZE (4)) ACCESS read-only STATUS mandatory DESCRIPTION "The received signalling state that represents the idle state. For E1 ports and T1 ESF ports, these bits represent the ABCD signalling bits on the interface.`x' means don't care. For E&M analog ports, Onhook is assumed for the idle state. The range is 0000 to 1111." ::= { cdx6500PPCTVoicePortEntry 61 } cdx6500VoiceCfgTransparentRxDisconnectFilter OBJECT-TYPE SYNTAX INTEGER (0..5) ACCESS read-only STATUS mandatory DESCRIPTION "The time the received signaling state must be equal to the idle state to disconnect the voice call. Zero value disables idle state disconnect and maintains the voice call in the answered state.Time is entered in minutes." ::= { cdx6500PPCTVoicePortEntry 62 } cdx6500VoiceCfgTransparentSignalingBusyoutState OBJECT-TYPE SYNTAX DisplayString (SIZE (4)) ACCESS read-only STATUS mandatory DESCRIPTION "The received signalling state that represents the Busyout state. For E1 ports and T1 ESF ports, these bits represent the ABCD signalling bits on the interface.For E&M analog ports, Offhook is assumed for the busyout/alarm state. The range is 0000 to 1111." ::= { cdx6500PPCTVoicePortEntry 63 } cdx6500VoiceCfgXlateSigInfo0000FromRemoteToLocalPort OBJECT-TYPE SYNTAX DisplayString (SIZE (4)) ACCESS read-only STATUS mandatory DESCRIPTION "Translate the signalling information received from the remote end to a value to be transmitted out the local port.If the local port is a T1/ESF or E1 port enter the ABCD values, for a T1/SF port, enter the AB(AB) value. If the local port is an analog E&M port, enter 0000 for idle (Onhook) and 1111 for active (Offhook). The range is 0000 to 1111." ::= { cdx6500PPCTVoicePortEntry 64 } cdx6500VoiceCfgXlateSigInfo1000FromRemoteToLocalPort OBJECT-TYPE SYNTAX DisplayString (SIZE (4)) ACCESS read-only STATUS mandatory DESCRIPTION "Translate the signalling information received from the remote end to a value to be transmitted out the local port.If the local port is a T1/ESF or E1 port enter the ABCD values, for a T1/SF port, enter the AB(AB) value. If the local port is an analog E&M port, enter 0000 for idle (Onhook) and 1111 for active (Offhook). The range is 0000 to 1111." ::= { cdx6500PPCTVoicePortEntry 65 } cdx6500VoiceCfgXlateSigInfo0100FromRemoteToLocalPort OBJECT-TYPE SYNTAX DisplayString (SIZE (4)) ACCESS read-only STATUS mandatory DESCRIPTION "Translate the signalling information received from the remote end to a value to be transmitted out the local port.If the local port is a T1/ESF or E1 port enter the ABCD values, for a T1/SF port, enter the AB(AB) value. If the local port is an analog E&M port, enter 0000 for idle (Onhook) and 1111 for active (Offhook). The range is 0000 to 1111." ::= { cdx6500PPCTVoicePortEntry 66 } cdx6500VoiceCfgXlateSigInfo1100FromRemoteToLocalPort OBJECT-TYPE SYNTAX DisplayString (SIZE (4)) ACCESS read-only STATUS mandatory DESCRIPTION "Translate the signalling information received from the remote end to a value to be transmitted out the local port.If the local port is a T1/ESF or E1 port enter the ABCD values, for a T1/SF port, enter the AB(AB) value. If the local port is an analog E&M port, enter 0000 for idle (Onhook) and 1111 for active (Offhook). The range is 0000 to 1111." ::= { cdx6500PPCTVoicePortEntry 67 } cdx6500VoiceCfgXlateSigInfo0010FromRemoteToLocalPort OBJECT-TYPE SYNTAX DisplayString (SIZE (4)) ACCESS read-only STATUS mandatory DESCRIPTION "Translate the signalling information received from the remote end to a value to be transmitted out the local port.If the local port is a T1/ESF or E1 port enter the ABCD values, for a T1/SF port, enter the AB(AB) value. If the local port is an analog E&M port, enter 0000 for idle (Onhook) and 1111 for active (Offhook). The range is 0000 to 1111." ::= { cdx6500PPCTVoicePortEntry 68 } cdx6500VoiceCfgXlateSigInfo1010FromRemoteToLocalPort OBJECT-TYPE SYNTAX DisplayString (SIZE (4)) ACCESS read-only STATUS mandatory DESCRIPTION "Translate the signalling information received from the remote end to a value to be transmitted out the local port.If the local port is a T1/ESF or E1 port enter the ABCD values, for a T1/SF port, enter the AB(AB) value. If the local port is an analog E&M port, enter 0000 for idle (Onhook) and 1111 for active (Offhook). The range is 0000 to 1111." ::= { cdx6500PPCTVoicePortEntry 69 } cdx6500VoiceCfgXlateSigInfo0110FromRemoteToLocalPort OBJECT-TYPE SYNTAX DisplayString (SIZE (4)) ACCESS read-only STATUS mandatory DESCRIPTION "Translate the signalling information received from the remote end to a value to be transmitted out the local port.If the local port is a T1/ESF or E1 port enter the ABCD values, for a T1/SF port, enter the AB(AB) value. If the local port is an analog E&M port, enter 0000 for idle (Onhook) and 1111 for active (Offhook). The range is 0000 to 1111." ::= { cdx6500PPCTVoicePortEntry 70 } cdx6500VoiceCfgXlateSigInfo1110FromRemoteToLocalPort OBJECT-TYPE SYNTAX DisplayString (SIZE (4)) ACCESS read-only STATUS mandatory DESCRIPTION "Translate the signalling information received from the remote end to a value to be transmitted out the local port.If the local port is a T1/ESF or E1 port enter the ABCD values, for a T1/SF port, enter the AB(AB) value. If the local port is an analog E&M port, enter 0000 for idle (Onhook) and 1111 for active (Offhook). The range is 0000 to 1111." ::= { cdx6500PPCTVoicePortEntry 71 } cdx6500VoiceCfgXlateSigInfo0001FromRemoteToLocalPort OBJECT-TYPE SYNTAX DisplayString (SIZE (4)) ACCESS read-only STATUS mandatory DESCRIPTION "Translate the signalling information received from the remote end to a value to be transmitted out the local port.If the local port is a T1/ESF or E1 port enter the ABCD values, for a T1/SF port, enter the AB(AB) value. If the local port is an analog E&M port, enter 0000 for idle (Onhook) and 1111 for active (Offhook). The range is 0000 to 1111." ::= { cdx6500PPCTVoicePortEntry 72 } cdx6500VoiceCfgXlateSigInfo1001FromRemoteToLocalPort OBJECT-TYPE SYNTAX DisplayString (SIZE (4)) ACCESS read-only STATUS mandatory DESCRIPTION "Translate the signalling information received from the remote end to a value to be transmitted out the local port.If the local port is a T1/ESF or E1 port enter the ABCD values, for a T1/SF port, enter the AB(AB) value. If the local port is an analog E&M port, enter 0000 for idle (Onhook) and 1111 for active (Offhook). The range is 0000 to 1111." ::= { cdx6500PPCTVoicePortEntry 73 } cdx6500VoiceCfgXlateSigInfo0101FromRemoteToLocalPort OBJECT-TYPE SYNTAX DisplayString (SIZE (4)) ACCESS read-only STATUS mandatory DESCRIPTION "Translate the signalling information received from the remote end to a value to be transmitted out the local port.If the local port is a T1/ESF or E1 port enter the ABCD values, for a T1/SF port, enter the AB(AB) value. If the local port is an analog E&M port, enter 0000 for idle (Onhook) and 1111 for active (Offhook). The range is 0000 to 1111." ::= { cdx6500PPCTVoicePortEntry 74 } cdx6500VoiceCfgXlateSigInfo1101FromRemoteToLocalPort OBJECT-TYPE SYNTAX DisplayString (SIZE (4)) ACCESS read-only STATUS mandatory DESCRIPTION "Translate the signalling information received from the remote end to a value to be transmitted out the local port.If the local port is a T1/ESF or E1 port enter the ABCD values, for a T1/SF port, enter the AB(AB) value. If the local port is an analog E&M port, enter 0000 for idle (Onhook) and 1111 for active (Offhook). The range is 0000 to 1111." ::= { cdx6500PPCTVoicePortEntry 75 } cdx6500VoiceCfgXlateSigInfo0011FromRemoteToLocalPort OBJECT-TYPE SYNTAX DisplayString (SIZE (4)) ACCESS read-only STATUS mandatory DESCRIPTION "Translate the signalling information received from the remote end to a value to be transmitted out the local port.If the local port is a T1/ESF or E1 port enter the ABCD values, for a T1/SF port, enter the AB(AB) value. If the local port is an analog E&M port, enter 0000 for idle (Onhook) and 1111 for active (Offhook). The range is 0000 to 1111." ::= { cdx6500PPCTVoicePortEntry 76 } cdx6500VoiceCfgXlateSigInfo1011FromRemoteToLocalPort OBJECT-TYPE SYNTAX DisplayString (SIZE (4)) ACCESS read-only STATUS mandatory DESCRIPTION "Translate the signalling information received from the remote end to a value to be transmitted out the local port.If the local port is a T1/ESF or E1 port enter the ABCD values, for a T1/SF port, enter the AB(AB) value. If the local port is an analog E&M port, enter 0000 for idle (Onhook) and 1111 for active (Offhook). The range is 0000 to 1111." ::= { cdx6500PPCTVoicePortEntry 77 } cdx6500VoiceCfgXlateSigInfo0111FromRemoteToLocalPort OBJECT-TYPE SYNTAX DisplayString (SIZE (4)) ACCESS read-only STATUS mandatory DESCRIPTION "Translate the signalling information received from the remote end to a value to be transmitted out the local port.If the local port is a T1/ESF or E1 port enter the ABCD values, for a T1/SF port, enter the AB(AB) value. If the local port is an analog E&M port, enter 0000 for idle (Onhook) and 1111 for active (Offhook). The range is 0000 to 1111." ::= { cdx6500PPCTVoicePortEntry 78 } cdx6500VoiceCfgXlateSigInfo1111FromRemoteToLocalPort OBJECT-TYPE SYNTAX DisplayString (SIZE (4)) ACCESS read-only STATUS mandatory DESCRIPTION "Translate the signalling information received from the remote end to a value to be transmitted out the local port.If the local port is a T1/ESF or E1 port enter the ABCD values, for a T1/SF port, enter the AB(AB) value. If the local port is an analog E&M port, enter 0000 for idle (Onhook) and 1111 for active (Offhook). The range is 0000 to 1111." ::= { cdx6500PPCTVoicePortEntry 79 } cdx6500VoiceCfgDialToneLowerFrequency OBJECT-TYPE SYNTAX INTEGER (200..3500) ACCESS read-only STATUS mandatory DESCRIPTION "The lower of the two frequencies needed to generate the dial tone." ::= { cdx6500PPCTVoicePortEntry 80 } cdx6500VoiceCfgDialToneLowerFrequencyAmplitude OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The amplitude of the lower frequency to generate the dial tone. To be specified in steps of 0.5dB, -30dB turn off output. The range is from -30dBm to -3dBm." ::= { cdx6500PPCTVoicePortEntry 81 } cdx6500VoiceCfgDialToneUpperFrequency OBJECT-TYPE SYNTAX INTEGER (200..3500) ACCESS read-only STATUS mandatory DESCRIPTION "The higher of the two frequencies needed to generate the dial tone." ::= { cdx6500PPCTVoicePortEntry 82 } cdx6500VoiceCfgDialToneUpperFrequencyAmplitude OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The amplitude of the upper frequency to generate the dial tone. To be specified in steps of 0.5dB, -30dB turn off output. The range is from -30dBm to -3dBm." ::= { cdx6500PPCTVoicePortEntry 83 } cdx6500VoiceCfgRingBackToneLowerFrequency OBJECT-TYPE SYNTAX INTEGER (200..3500) ACCESS read-only STATUS mandatory DESCRIPTION "The lower of the two frequencies needed to generate the Ringback tone." ::= { cdx6500PPCTVoicePortEntry 84 } cdx6500VoiceCfgRingBackToneLowerFrequencyAmplitude OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The amplitude of the lower frequency to generate the Ringback tone. To be specified in steps of 0.5dB, -30dB turn off output.The range is from -30dBm to -3dBm." ::= { cdx6500PPCTVoicePortEntry 85 } cdx6500VoiceCfgRingBackToneUpperFrequency OBJECT-TYPE SYNTAX INTEGER (200..3500) ACCESS read-only STATUS mandatory DESCRIPTION "The higher of the two frequencies needed to generate the Ring-back tone." ::= { cdx6500PPCTVoicePortEntry 86 } cdx6500VoiceCfgRingBackToneUpperFrequencyAmplitude OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The amplitude of the upper frequency to generate the Ringback tone. To be specified in steps of 0.5dB, -30dB turn off output. The range is from -30dBm to -3dBm." ::= { cdx6500PPCTVoicePortEntry 87 } cdx6500VoiceCfgBusyToneLowerFrequency OBJECT-TYPE SYNTAX INTEGER (200..3500) ACCESS read-only STATUS mandatory DESCRIPTION "The lower of the two frequencies needed to generate the Busy tone." ::= { cdx6500PPCTVoicePortEntry 88 } cdx6500VoiceCfgBusyToneLowerFrequencyAmplitude OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The amplitude of the lower frequency to generate the Busy tone. To be specified in steps of 0.5dB, -30dB turn off output. The range is from -30dBm to -3dBm." ::= { cdx6500PPCTVoicePortEntry 89 } cdx6500VoiceCfgBusyToneUpperFrequency OBJECT-TYPE SYNTAX INTEGER (200..3500) ACCESS read-only STATUS mandatory DESCRIPTION "The higher of the two frequencies needed to generate the Busy tone." ::= { cdx6500PPCTVoicePortEntry 90 } cdx6500VoiceCfgBusyToneUpperFrequencyAmplitude OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The amplitude of the upper frequency to generate the Busy tone. To be specified in steps of 0.5dB, -30dB turn off output. The range is from -30dBm to -3dBm." ::= { cdx6500PPCTVoicePortEntry 91 } cdx6500VoiceCfgTxBusyToneOffTime OBJECT-TYPE SYNTAX INTEGER (100..1000) ACCESS read-only STATUS mandatory DESCRIPTION "Timer for the Busy tone off state. Granularity is 50 milliseconds." ::= { cdx6500PPCTVoicePortEntry 92 } cdx6500VoiceCfgTxBusyToneOnTime OBJECT-TYPE SYNTAX INTEGER (100..1000) ACCESS read-only STATUS mandatory DESCRIPTION "Timer for the busy tone on state. Granularity is 50 milliseconds." ::= { cdx6500PPCTVoicePortEntry 93 } cdx6500VoiceCfgFastBusyToneLowerFrequency OBJECT-TYPE SYNTAX INTEGER (200..3500) ACCESS read-only STATUS mandatory DESCRIPTION "The lower of the two frequencies needed to generate the Fast Busy tone." ::= { cdx6500PPCTVoicePortEntry 94 } cdx6500VoiceCfgFastBusyToneLowerFrequencyAmplitude OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The amplitude of the lower frequency to generate the Fast Busy tone. To be specified in steps of 0.5dB, -30dB turn off output. The range is from -30dBm to -3dBm." ::= { cdx6500PPCTVoicePortEntry 95 } cdx6500VoiceCfgFastBusyToneUpperFrequency OBJECT-TYPE SYNTAX INTEGER (200..3500) ACCESS read-only STATUS mandatory DESCRIPTION "The higher of the two frequencies needed to generate the Fast Busy tone." ::= { cdx6500PPCTVoicePortEntry 96 } cdx6500VoiceCfgFastBusyToneUpperFrequencyAmplitude OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The amplitude of the upper frequency to generate the Fast Busy tone. To be specified in steps of 0.5dB, -30dB turn off output. The range is from -30dBm to -3dBm." ::= { cdx6500PPCTVoicePortEntry 97 } cdx6500VoiceCfgTxFastBusyToneOffTime OBJECT-TYPE SYNTAX INTEGER (100..1000) ACCESS read-only STATUS mandatory DESCRIPTION "Timer for the Fast Busy tone off state. Granularity is 50 milliseconds." ::= { cdx6500PPCTVoicePortEntry 98 } cdx6500VoiceCfgTxFastBusyToneOnTime OBJECT-TYPE SYNTAX INTEGER (100..1000) ACCESS read-only STATUS mandatory DESCRIPTION "Timer for the Fast Busy tone on state. Granularity is 50 milliseconds." ::= { cdx6500PPCTVoicePortEntry 99 } cdx6500VoiceCfgHybridFXO OBJECT-TYPE SYNTAX INTEGER { sixHundred (1), adaptive (11), nc (100) } ACCESS read-only STATUS mandatory DESCRIPTION "Hybrid balance filters. sixHundred : 600 ohm interface. adaptive : 600 ohm with adaptive filter. nc : Skipped during configuration. This parameter is displayed for DSPM/HC (FXO) and skipped for DSPM/E&M, DSPM/FXS and all virtual port types." ::= { cdx6500PPCTVoicePortEntry 100 } cdx6500VoiceCfgTxPulse OBJECT-TYPE SYNTAX INTEGER (50..200) ACCESS read-only STATUS mandatory DESCRIPTION "The width of the transmitted Seizure, PTS, or Answer pulse in msec." ::= { cdx6500PPCTVoicePortEntry 101 } cdx6500VoiceCfgRxMinPulse OBJECT-TYPE SYNTAX INTEGER (50..200) ACCESS read-only STATUS mandatory DESCRIPTION "The minimum pulse width to declare a valid received Seizure, PTS, or Answer pulse." ::= { cdx6500PPCTVoicePortEntry 102 } cdx6500VoiceCfgRxMaxPulse OBJECT-TYPE SYNTAX INTEGER (50..200) ACCESS read-only STATUS mandatory DESCRIPTION "The maximum pulse width to declare a valid received Seizure, PTS, or Answer." ::= { cdx6500PPCTVoicePortEntry 103 } cdx6500VoiceCfgTxMasterClear OBJECT-TYPE SYNTAX INTEGER (400..2000) ACCESS read-only STATUS mandatory DESCRIPTION "The width of the transmitted Master Clear-Forward, Clear-Back, or Release Guard pulse in msec." ::= { cdx6500PPCTVoicePortEntry 104 } cdx6500VoiceCfgRxMinMasterClear OBJECT-TYPE SYNTAX INTEGER (400..2000) ACCESS read-only STATUS mandatory DESCRIPTION "The minimum pulse width to declare a valid received Master Clear-Forward, Clear-Back, or Release Guard." ::= { cdx6500PPCTVoicePortEntry 105 } cdx6500VoiceCfgRxMaxMasterClear OBJECT-TYPE SYNTAX INTEGER (400..2000) ACCESS read-only STATUS mandatory DESCRIPTION "The maximum pulse width to declare a valid received Master Clear-Forward, Clear-Back, or Release Guard." ::= { cdx6500PPCTVoicePortEntry 106 } cdx6500VoiceCfgTxSlaveClear OBJECT-TYPE SYNTAX INTEGER (400..2000) ACCESS read-only STATUS mandatory DESCRIPTION "The width of the transmitted Slave Clear-Forward or Clear-Back pulse in msec." ::= { cdx6500PPCTVoicePortEntry 107 } cdx6500VoiceCfgRxMinSlaveClear OBJECT-TYPE SYNTAX INTEGER (400..2000) ACCESS read-only STATUS mandatory DESCRIPTION "The minimum pulse width to declare a valid received Slave Clear-Forward or Clear-Back." ::= { cdx6500PPCTVoicePortEntry 108 } cdx6500VoiceCfgRxMaxSlaveClear OBJECT-TYPE SYNTAX INTEGER (400..2000) ACCESS read-only STATUS mandatory DESCRIPTION "The maximum pulse width to declare a valid received Slave Clear-Forward or Clear-Back." ::= { cdx6500PPCTVoicePortEntry 109 } cdx6500VoiceCfgTxSlaveRelease OBJECT-TYPE SYNTAX INTEGER (0..2000) ACCESS read-only STATUS mandatory DESCRIPTION "The width of the transmitted Slave Release Guard pulse in msec." ::= { cdx6500PPCTVoicePortEntry 110 } cdx6500VoiceCfgRxMinSlaveRelease OBJECT-TYPE SYNTAX INTEGER (0..2000) ACCESS read-only STATUS mandatory DESCRIPTION "The minimum pulse width to declare a valid received Slave Release Guard." ::= { cdx6500PPCTVoicePortEntry 111 } cdx6500VoiceCfgRxMaxSlaveRelease OBJECT-TYPE SYNTAX INTEGER (0..2000) ACCESS read-only STATUS mandatory DESCRIPTION "The maximum pulse width to declare a valid received Slave Release Guard." ::= { cdx6500PPCTVoicePortEntry 112 } cdx6500VoiceCfgTxPTSTime OBJECT-TYPE SYNTAX INTEGER (0..2000) ACCESS read-only STATUS mandatory DESCRIPTION "The time delay from receiving a valid Seizure from the PBX to start transmitting a PTS pulse." ::= { cdx6500PPCTVoicePortEntry 113 } cdx6500VoiceCfgRxPTSTime OBJECT-TYPE SYNTAX INTEGER (0..2000) ACCESS read-only STATUS mandatory DESCRIPTION "The maximum time to wait for a PTS pulse from the PBX after sending a Seizure before giving up and clearing the trunk." ::= { cdx6500PPCTVoicePortEntry 114 } cdx6500VoiceCfgMasterGuard OBJECT-TYPE SYNTAX INTEGER (0..2000) ACCESS read-only STATUS mandatory DESCRIPTION "The time the master side waits in the guard state after transmitting a clear pulse." ::= { cdx6500PPCTVoicePortEntry 115 } cdx6500VoiceCfgSlaveGuard OBJECT-TYPE SYNTAX INTEGER (0..2000) ACCESS read-only STATUS mandatory DESCRIPTION "The time the slave side waits in the guard state after transmitting a clear pulse." ::= { cdx6500PPCTVoicePortEntry 116 } cdx6500VoiceCfgTxFlashHookTime OBJECT-TYPE SYNTAX INTEGER (100..10000) ACCESS read-only STATUS mandatory DESCRIPTION "The lenght of time a flash signal will be transmitted as a result of a flash-hook from the remote interface." ::= { cdx6500PPCTVoicePortEntry 117 } cdx6500VoiceCfgDtmfAmplitude OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The amplitude of the DTMF digits. To be specified in steps of 0.5dB, -30.0 turn off output. The range is from -30dBm to -3dBm." ::= { cdx6500PPCTVoicePortEntry 118 } cdx6500VoiceCfgFXSOffhookFilter OBJECT-TYPE SYNTAX INTEGER (20..500) ACCESS read-only STATUS mandatory DESCRIPTION "This is the amoung of time a valid OFFHOOK conidtion must be present before an analog FXS will declare OFFHOOK." ::= { cdx6500PPCTVoicePortEntry 119 } -- Voice Switch Configuration Table cdx6500GGCTVoiceSwitchTable OBJECT-TYPE SYNTAX SEQUENCE OF Cdx6500VoiceSwitchEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the Voice Switch Table configuration." ::= { cdx6500GCTVoiceSwitchTable 1 } cdx6500VoiceSwitchEntry OBJECT-TYPE SYNTAX Cdx6500VoiceSwitchEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry contains a list of parameters that makeup the Voice Switch Table." INDEX { cdx6500VoiceSwitchEntryNumber } ::= { cdx6500GGCTVoiceSwitchTable 1 } Cdx6500VoiceSwitchEntry ::= SEQUENCE { cdx6500VoiceSwitchRxDTMFDigitString DisplayString, cdx6500VoiceSwitchNumRxDigitToReceive INTEGER, cdx6500VoiceSwitchCallParam DisplayString, cdx6500VoiceSwitchAlternateDestination INTEGER, cdx6500VoiceSwitchCompressionOverrideRate INTEGER, cdx6500VoiceSwitchNumLeadingDigitToStrip INTEGER, cdx6500VoiceSwitchPreFixDigits DisplayString, cdx6500VoiceSwitchPostFixDigits DisplayString, cdx6500VoiceSwitchEntryNumber INTEGER } cdx6500VoiceSwitchRxDTMFDigitString OBJECT-TYPE SYNTAX DisplayString (SIZE (0..20)) ACCESS read-only STATUS mandatory DESCRIPTION "Select the voice number plans for the 6520/6560 network. The received DTMF digits received by the voice interface is compared to this parameter. - Enter a trailing asterisk(*) as a wild-card. - Use the space bar to blank the parameter. Range: 1 to 20 characters (valid characters are 0 through 9, '-', ',', '/', and '*'). The characters '-', ',', and '/' are allowed only for ease of reading. They are not sent to the remote port. Note: The maximum number of digits that can be sent to the remote end is 16." ::= { cdx6500VoiceSwitchEntry 1 } cdx6500VoiceSwitchNumRxDigitToReceive OBJECT-TYPE SYNTAX INTEGER (1..20) ACCESS read-only STATUS mandatory DESCRIPTION "Select the number of DTMF digits to be received before making the call request." ::= { cdx6500VoiceSwitchEntry 2 } cdx6500VoiceSwitchCallParam OBJECT-TYPE SYNTAX DisplayString (SIZE (0..20)) ACCESS read-only STATUS mandatory DESCRIPTION "Define the network address of the called node and the port or Hunt Group number of the desired destination port." ::= { cdx6500VoiceSwitchEntry 3 } cdx6500VoiceSwitchAlternateDestination OBJECT-TYPE SYNTAX INTEGER { deprecatedObj (1) } ACCESS read-only STATUS deprecated DESCRIPTION "This object is no longer supported." ::= { cdx6500VoiceSwitchEntry 4 } cdx6500VoiceSwitchCompressionOverrideRate OBJECT-TYPE SYNTAX INTEGER { none (6), cD8K (7), cD16K (8), cBD8K (10), cBD16K (11), cE8Kb (14), cE16Kb (15), nc (100) } ACCESS read-only STATUS mandatory DESCRIPTION "Select the voice compression override algorithm. none - No override, use port configured value. c8k - 8k CVSELP c16k - 16k CVSELP cB8k - Bundled 8k CVSELP cB16k - Bundled 16k CVSELP cE8Kb - Enhanced Bundled 8k CVSELP cE8Kb - Enhanced Bundled 16k CVSELP nc - Skipped during configuration." ::= { cdx6500VoiceSwitchEntry 5 } cdx6500VoiceSwitchNumLeadingDigitToStrip OBJECT-TYPE SYNTAX INTEGER (0..20) ACCESS read-only STATUS mandatory DESCRIPTION "Select the number of leading digits to be stripped off the received digits stream before sending the digits stream to the remote port." ::= { cdx6500VoiceSwitchEntry 6 } cdx6500VoiceSwitchPreFixDigits OBJECT-TYPE SYNTAX DisplayString (SIZE (0..20)) ACCESS read-only STATUS mandatory DESCRIPTION "Select digits to be added in front of or at the end of the received stream (after the stripped digits are removed) before sending the digit stream to the remote port. Range: 1 to 20 characters (valid characters are 0 through 9, '*', '#', 'R', 'P', and '-'). The character '-' is allowed only for ease of reading. It is not sent to the remote port. The 'P' character is used to indicate a pause is required in the playout of the digits at the remote end. The length of the pause is equal to 'Tx Interdigit Pause Time' as defined at the called port (destination port). Leading 'P' characters are not supported. The character 'R' is used to separate the prefix digit string from the postfix digit string Note: The maximum number of digits that can be sent to the remote end is 16." ::= { cdx6500VoiceSwitchEntry 7 } cdx6500VoiceSwitchPostFixDigits OBJECT-TYPE SYNTAX DisplayString (SIZE (0..20)) ACCESS read-only STATUS deprecated DESCRIPTION "Select DTMF digits to be added at the end of the received DTMF stream before sending the digit stream to the remote port. Range: 1 to 20 characters (valid characters are 0 through 9, '-', ',', '/', '*', '#', and 'P'). The characters '-', ',', and '/' are allowed only for ease of reading. They are not sent to the remote port. The 'P' character is used to indicate a pause is required in the playout of the digits at the remote end. The length of the pause is equal to 'Tx Interdigit Pause Time' as defined at the called port (destination port). Note: The maximum number of digits that can be sent to the remote end is 16. This object is no longer supported." ::= { cdx6500VoiceSwitchEntry 8 } cdx6500VoiceSwitchEntryNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This is the entry number in the Voice Switch Table." ::= { cdx6500VoiceSwitchEntry 9 } -- Voice Port Statistics Table cdx6500PPSTVoicePortTable OBJECT-TYPE SYNTAX SEQUENCE OF Cdx6500PPSTVoicePortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the port statistics for Voice ports." ::= { cdx6500PSTVoicePortTable 1 } cdx6500PPSTVoicePortEntry OBJECT-TYPE SYNTAX Cdx6500PPSTVoicePortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A Voice Port Statistics Table Entry. Each entry contains the statistics for a single Voice Port." INDEX { cdx6500VoiceStatsPortNumber } ::= { cdx6500PPSTVoicePortTable 1 } Cdx6500PPSTVoicePortEntry ::= SEQUENCE { cdx6500VoiceStatsPortNumber INTEGER, cdx6500VoiceStatsPortInterfaceType INTEGER, cdx6500VoiceStatsHWRevAndPartNumber DisplayString, cdx6500VoiceStatsFortyEightVolts INTEGER, cdx6500VoiceStatsPortState INTEGER, cdx6500VoiceStatsCircuitState INTEGER, cdx6500VoiceStatsCurrentMode INTEGER, cdx6500VoiceStatsTimeOfLastStatReset DisplayString, cdx6500VoiceStatsCallDuration DisplayString, cdx6500VoiceStatsTotalCallDuration DisplayString, cdx6500VoiceStatsPortUtilization INTEGER, cdx6500VoiceStatsNumberOfCalls Counter, cdx6500VoiceStatsLastDigitsTransmitted DisplayString, cdx6500VoiceStatsLastDigitsReceived DisplayString, cdx6500VoiceStatsTxPacketDropped Counter, cdx6500VoiceStatsRxPacketDropped Counter, cdx6500VoiceStatsDroppedPackets Counter, cdx6500VoiceStatsDSPInternalFaults Counter, cdx6500VoiceStatsTxPackets Counter, cdx6500VoiceStatsRxPackets Counter, cdx6500VoiceStatsTxPacketsPerSecond Counter, cdx6500VoiceStatsRxPacketsPerSecond Counter, cdx6500VoiceStatsDSIEfficiency INTEGER, cdx6500VoiceStatsCurrentRate INTEGER, cdx6500VoiceStatsInputPower DisplayString, cdx6500VoiceStatsOutputPower DisplayString, cdx6500VoiceStatsFAXTransmissions INTEGER, cdx6500VoiceStatsUnsupportedFmtsFAXXmissions INTEGER, cdx6500PPSTSignalingSequenceTrapTxState DisplayString, cdx6500PPSTSignalingSequenceTrapRxState DisplayString, cdx6500PPSTSignalingSequenceTrapMachineState DisplayString, cdx6500PPSTSignalingSequenceTrapTimeSinceLastChange INTEGER, cdx6500PPSTSignalingSequenceTrapComment DisplayString, cdx6500VoiceStatsCurrentStatus INTEGER, cdx6500VoiceStatsLastClearCauseCode DisplayString, cdx6500VoiceStatsLastClearDiagnosticCode DisplayString, cdx6500VoiceStatsLastInboundCallPacketCalledAddress DisplayString, cdx6500VoiceStatsLastInboundCallPacketCallingAddress DisplayString, cdx6500VoiceStatsLastInboundCallPacketFacilities DisplayString, cdx6500VoiceStatsLastInboundCallPacketCUD DisplayString, cdx6500VoiceStatsLastOutboundCallPacketCalledAddress DisplayString, cdx6500VoiceStatsLastOutboundCallPacketCallingAddress DisplayString, cdx6500VoiceStatsLastOutboundCallPacketFacilities DisplayString, cdx6500VoiceStatsLastOutboundCallPacketCUD DisplayString, cdx6500VoiceStatsRingerStatus INTEGER, cdx6500VoiceStatsDSPMSMSlotNumber INTEGER, cdx6500VoiceStatsDSPMNumber INTEGER, cdx6500VoiceStatsT1E1PortNumber INTEGER, cdx6500VoiceStatsTimeSlotNumber DisplayString, cdx6500VoiceStatsDaughterCardRevAndPartNumber DisplayString, cdx6500VoiceStatsVADEfficiency INTEGER, cdx6500VoiceStatsMeanDelayDeviation INTEGER, cdx6500VoiceStatsMaxDelayDeviation DisplayString, cdx6500VoiceStatsPktRecResync INTEGER, cdx6500VoiceCallStatsNoPacketDropped DisplayString, cdx6500VoiceCallStatsNoCallsDropped DisplayString, cdx6500VoiceCallStatsDroppedReason0 DisplayString, cdx6500VoiceCallStatsDroppedReason1 DisplayString, cdx6500VoiceCallStatsDroppedReason3 DisplayString, cdx6500VoiceCallStatsDroppedReason5 DisplayString, cdx6500VoiceCallStatsDroppedReason9 DisplayString, cdx6500VoiceCallStatsDroppedReason11 DisplayString, cdx6500VoiceCallStatsDroppedReason13 DisplayString, cdx6500VoiceCallStatsDroppedReason17 DisplayString, cdx6500VoiceCallStatsDroppedReason19 DisplayString, cdx6500VoiceCallStatsDroppedReason21 DisplayString, cdx6500VoiceCallStatsDroppedReason33 DisplayString, cdx6500VoiceCallStatsDroppedReason-Rest DisplayString } cdx6500VoiceStatsPortNumber OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "Port number of the Voice Port." ::= { cdx6500PPSTVoicePortEntry 1 } cdx6500VoiceStatsPortInterfaceType OBJECT-TYPE SYNTAX INTEGER { eAndM2 (1), eAndM4 (2), fxo (3), fxs (4) } ACCESS read-only STATUS mandatory DESCRIPTION "This parameter indicates the type of DPSM card used. eAndM2 : DPSM/E&M. eAndM4 : DPSM/E&M. fxo : DPSM/HC(FXO). fxs : DPSM/FXS." ::= { cdx6500PPSTVoicePortEntry 2 } cdx6500VoiceStatsHWRevAndPartNumber OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Hardware revision and part number of the main card. The revision number has format n.n and the part number is an 8 digit number of the form nnnnnnnn." ::= { cdx6500PPSTVoicePortEntry 3 } cdx6500VoiceStatsFortyEightVolts OBJECT-TYPE SYNTAX INTEGER { none (1), present (2), na (100) } ACCESS read-only STATUS mandatory DESCRIPTION "This parameter indicates whether the 48 volt power supply is installed in the node. none : power supply not installed. present : power supply installed. na : Value not available. This parameter will not be displayed for DSPM/HC." ::= { cdx6500PPSTVoicePortEntry 4 } cdx6500VoiceStatsPortState OBJECT-TYPE SYNTAX INTEGER { disabled (1), enabled (2) } ACCESS read-only STATUS mandatory DESCRIPTION "This parameter indicates ths status of the port. disabled : The port is disabled. enabled : The port is enabled." ::= { cdx6500PPSTVoicePortEntry 5 } cdx6500VoiceStatsCircuitState OBJECT-TYPE SYNTAX INTEGER { connected (1), disconnected (2) } ACCESS read-only STATUS mandatory DESCRIPTION "This parameter indicates the state of the SVC associated with this port. connected : SVC established. disconnected : SVC not established." ::= { cdx6500PPSTVoicePortEntry 6 } cdx6500VoiceStatsCurrentMode OBJECT-TYPE SYNTAX INTEGER { voice (1), pcm (2), fax (3) } ACCESS read-only STATUS mandatory DESCRIPTION "This parameter indicates the current operating mode of the DSP. voice : DSP is currently operating in voice mode. pcm : PCM mode is not supported. fax : DSP is currently operating in fax mode." ::= { cdx6500PPSTVoicePortEntry 7 } cdx6500VoiceStatsTimeOfLastStatReset OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This parameter indicates the time since the last statistic reset using the format month:day:year:hours:minutes:seconds (mm:dd:yyyy:hh:mm:ss)." ::= { cdx6500PPSTVoicePortEntry 8 } cdx6500VoiceStatsCallDuration OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This parameter indicates the duration of the current (last) call using the format hours:minutes:seconds (hh:mm:ss)." ::= { cdx6500PPSTVoicePortEntry 9 } cdx6500VoiceStatsTotalCallDuration OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This parameter indicates the total time of all calls since last reset.It is measured from Offhook to Onhook and uses the format hours:minutes:seconds (hh:mm:ss)." ::= { cdx6500PPSTVoicePortEntry 10 } cdx6500VoiceStatsPortUtilization OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-only STATUS mandatory DESCRIPTION "This parameter is calculated as the ratio of `Total Call Duration' to `Time Of Last Reset'. It is a percentage value of the form nnn%." ::= { cdx6500PPSTVoicePortEntry 11 } cdx6500VoiceStatsNumberOfCalls OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This parameter indicates the total number of calls since the last reset." ::= { cdx6500PPSTVoicePortEntry 12 } cdx6500VoiceStatsLastDigitsTransmitted OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This parameter indicates the last DTMF digits transmitted to the voice interface. Not supported at this time." ::= { cdx6500PPSTVoicePortEntry 13 } cdx6500VoiceStatsLastDigitsReceived OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This parameter indicates the last DTMF digits received from the voice interface. Not supported at this time." ::= { cdx6500PPSTVoicePortEntry 14 } cdx6500VoiceStatsTxPacketDropped OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This parameter indicates the number of times transmit packets were dropped due to DSPM congestion." ::= { cdx6500PPSTVoicePortEntry 15 } cdx6500VoiceStatsRxPacketDropped OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This parameter indicates the number of times receive packets were dropped due to network overload or processor loading." ::= { cdx6500PPSTVoicePortEntry 16 } cdx6500VoiceStatsDroppedPackets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This parameter indicates the estimate of packets dropped end to end in the network." ::= { cdx6500PPSTVoicePortEntry 17 } cdx6500VoiceStatsDSPInternalFaults OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This parameter indicates the number of recoverable software faults.It is displayed only when the DEBUG flag is set." ::= { cdx6500PPSTVoicePortEntry 18 } cdx6500VoiceStatsTxPackets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This parameter indicates the number of packets received from the network port since the last reset." ::= { cdx6500PPSTVoicePortEntry 19 } cdx6500VoiceStatsRxPackets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This parameter indicates the number of packets sent to the network port since the last reset." ::= { cdx6500PPSTVoicePortEntry 20 } cdx6500VoiceStatsTxPacketsPerSecond OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This parameter indicates the average number of packets transmitted per second.It is calculated as the ratio of `Tx Packets' to `Total Call Duration'." ::= { cdx6500PPSTVoicePortEntry 21 } cdx6500VoiceStatsRxPacketsPerSecond OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This parameter indicates the average number of packets received per second.It is calculated as the ratio of `Rx Packets' to `Total Call Duration'." ::= { cdx6500PPSTVoicePortEntry 22 } cdx6500VoiceStatsDSIEfficiency OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-only STATUS mandatory DESCRIPTION "This parameter is calculated by dividing `Rx Packets/sec' by the packet rate. It is a percentage value." ::= { cdx6500PPSTVoicePortEntry 23 } cdx6500VoiceStatsCurrentRate OBJECT-TYPE SYNTAX INTEGER { cD8K (1), cBD8K (2), cE8Kb (3), cD16K (4), cBD16K (5), cE16Kb (6), cPcm (7), cFax (8), na (100) } ACCESS read-only STATUS mandatory DESCRIPTION "This parameter indicates the current compression rate being used. cD8K : Compression rate is 8K. cBD8K : Compression rate is bundled 8K. cE8Kb : Compression rate is Enhanced bundled D8K. cD16K : Compression rate is 16K. cBD16K : Compression rate is bundled 16K. cE16Kb : Compression rate is Enhanced bundled D16K. cPcm : Compression rate is PCM. cFax : Compression rate is FAX. na : Value not available." ::= { cdx6500PPSTVoicePortEntry 24 } cdx6500VoiceStatsInputPower OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This parameter indicates the input power level in dBm. (Measured power)." ::= { cdx6500PPSTVoicePortEntry 25 } cdx6500VoiceStatsOutputPower OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This parameter indicates the output power level in dBm. (Measured power)." ::= { cdx6500PPSTVoicePortEntry 26 } cdx6500VoiceStatsFAXTransmissions OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This parameter indicates the number of FAX transmissions spoofed." ::= { cdx6500PPSTVoicePortEntry 27 } cdx6500VoiceStatsUnsupportedFmtsFAXXmissions OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This parameter indicates the number of FAX transmissions requesting unsupported formats but transmitted using ISG formats." ::= { cdx6500PPSTVoicePortEntry 28 } cdx6500PPSTSignalingSequenceTrapTxState OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS deprecated DESCRIPTION "The transmitting voice signalling state is displayed as ABCD (i.e. 1010). This object is no longer supported. Refer to cdx6500SignalingSequenceTrapTxState." ::= { cdx6500PPSTVoicePortEntry 29 } cdx6500PPSTSignalingSequenceTrapRxState OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS deprecated DESCRIPTION "The receiving voice signalling state is displayed as ABCD (i.e. 1010). This object is no longer supported. Refer to cdx6500SignalingSequenceTrapRxState." ::= { cdx6500PPSTVoicePortEntry 30 } cdx6500PPSTSignalingSequenceTrapMachineState OBJECT-TYPE SYNTAX DisplayString (SIZE (11)) ACCESS read-only STATUS deprecated DESCRIPTION "The voice signalling state machine state is a 11 character field representing the state of the signalling software. This object is no longer supported. Refer to cdx6500SignalingSequenceTrapMachineState." ::= { cdx6500PPSTVoicePortEntry 31 } cdx6500PPSTSignalingSequenceTrapTimeSinceLastChange OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS deprecated DESCRIPTION "This parameter indicates the time from the previous state to this state, measured in milliseconds. This object is no longer supported. Refer to cdx6500SignalingSequenceTrapTimeSinceLastChange." ::= { cdx6500PPSTVoicePortEntry 32 } cdx6500PPSTSignalingSequenceTrapComment OBJECT-TYPE SYNTAX DisplayString (SIZE (0..16)) ACCESS read-only STATUS deprecated DESCRIPTION "The comment field is an ASCII string upto 16 characters long. This object is no longer supported. Refer to cdx6500SignalingSequenceTrapComment." ::= { cdx6500PPSTVoicePortEntry 33 } cdx6500VoiceStatsCurrentStatus OBJECT-TYPE SYNTAX INTEGER { inhibited (1), disconnected (2), calling (3), called (4), connected (5), null (6) } ACCESS read-only STATUS mandatory DESCRIPTION "This is the call processing state machine status. inhibited : Current Status = Disconnected. disconnected : Current Status = Disconnected. calling : Current Status = Calling. called : Current Status = Called. connected : Current Status = Connected (data transfer). null : Current Status = Undefined." ::= { cdx6500PPSTVoicePortEntry 34 } cdx6500VoiceStatsLastClearCauseCode OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This parameter indicates the last clear cause code received Every code corresponds to an integer value followed by its text description in paranthesis. eg.Consider the clear cause code for `number busy' which is CAUSE-CLR-NUM-BSY. This corresponds to : 001 (number busy)." ::= { cdx6500PPSTVoicePortEntry 35 } cdx6500VoiceStatsLastClearDiagnosticCode OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This parameter indicates the last clear diagnostic received.Every code corresponds to an integer value followed by its text description in paranthesis. eg.Consider the diagnostic code for `invalid bits in packet' which is DIAG-INV-PKT-BITS.This corresponds to :041 (invalid bits in packet)." ::= { cdx6500PPSTVoicePortEntry 36 } cdx6500VoiceStatsLastInboundCallPacketCalledAddress OBJECT-TYPE SYNTAX DisplayString (SIZE (3..15)) ACCESS read-only STATUS mandatory DESCRIPTION "This parameter contains the called address present in the last inbound call packet." ::= { cdx6500PPSTVoicePortEntry 37 } cdx6500VoiceStatsLastInboundCallPacketCallingAddress OBJECT-TYPE SYNTAX DisplayString (SIZE (3..15)) ACCESS read-only STATUS mandatory DESCRIPTION "This parameter contains the calling address present in the last inbound call packet." ::= { cdx6500PPSTVoicePortEntry 38 } cdx6500VoiceStatsLastInboundCallPacketFacilities OBJECT-TYPE SYNTAX DisplayString (SIZE (0..105)) ACCESS read-only STATUS mandatory DESCRIPTION "This parameter contains the facilities present in the last inbound call packet." ::= { cdx6500PPSTVoicePortEntry 39 } cdx6500VoiceStatsLastInboundCallPacketCUD OBJECT-TYPE SYNTAX DisplayString (SIZE (0..16)) ACCESS read-only STATUS mandatory DESCRIPTION "This parameter contains the call user data present in the last inbound call packet." ::= { cdx6500PPSTVoicePortEntry 40 } cdx6500VoiceStatsLastOutboundCallPacketCalledAddress OBJECT-TYPE SYNTAX DisplayString (SIZE (3..15)) ACCESS read-only STATUS mandatory DESCRIPTION "This parameter contains the called address present in the last outbound call packet." ::= { cdx6500PPSTVoicePortEntry 41 } cdx6500VoiceStatsLastOutboundCallPacketCallingAddress OBJECT-TYPE SYNTAX DisplayString (SIZE (3..15)) ACCESS read-only STATUS mandatory DESCRIPTION "This parameter contains the calling address present in the last outbound call packet." ::= { cdx6500PPSTVoicePortEntry 42 } cdx6500VoiceStatsLastOutboundCallPacketFacilities OBJECT-TYPE SYNTAX DisplayString (SIZE (0..105)) ACCESS read-only STATUS mandatory DESCRIPTION "This parameter contains the facilities present in the last outbound call packet." ::= { cdx6500PPSTVoicePortEntry 43 } cdx6500VoiceStatsLastOutboundCallPacketCUD OBJECT-TYPE SYNTAX DisplayString (SIZE (0..16)) ACCESS read-only STATUS mandatory DESCRIPTION "This parameter contains the call user data present in the last outbound call packet." ::= { cdx6500PPSTVoicePortEntry 44 } cdx6500VoiceStatsRingerStatus OBJECT-TYPE SYNTAX INTEGER { rs25Hz (1), rs50Hz (2), na (100) } ACCESS read-only STATUS mandatory DESCRIPTION "This parameter indicates the Ringer status on the board. It is displayed only for DSPM/FXS interfaces. rs25Hz : 25Hz Ringer status on board. rs50Hz : 50Hz Ringer status on board. na : Value not available." ::= { cdx6500PPSTVoicePortEntry 45 } cdx6500VoiceStatsDSPMSMSlotNumber OBJECT-TYPE SYNTAX INTEGER (0..99) ACCESS read-only STATUS mandatory DESCRIPTION "This parameter indicates the slot of the DSPM/SM. It is displayed only for DSPM/SM interfaces. A value of 0 indicates that this parameter is not available." ::= { cdx6500PPSTVoicePortEntry 46 } cdx6500VoiceStatsDSPMNumber OBJECT-TYPE SYNTAX INTEGER (0..4) ACCESS read-only STATUS mandatory DESCRIPTION "This parameter indicates the DSP used for the virtual port.It is displayed only for DSPM/SM interfaces. A value of 0 indicates that this parameter is not available." ::= { cdx6500PPSTVoicePortEntry 47 } cdx6500VoiceStatsT1E1PortNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This is the port number of the T1 or E1 port this voice channel is on.It is displayed only for DSPM/SM interfaces. A value of 0 indicates that this parameter is not available." ::= { cdx6500PPSTVoicePortEntry 48 } cdx6500VoiceStatsTimeSlotNumber OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This parameter indicates the time slot number. It is displayed only for DSPM/SM interfaces. For multiple time slots it will be displayed as 1,2-5,.." ::= { cdx6500PPSTVoicePortEntry 49 } cdx6500VoiceStatsDaughterCardRevAndPartNumber OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Hardware revision and part number of the daughter card.The revision number has format n.n and the part number is an 8 digit number of the form nnnnnnnn.It is displayed only for DSPM/HC interfaces." ::= { cdx6500PPSTVoicePortEntry 50 } cdx6500VoiceStatsVADEfficiency OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "VAD (Voice Activity Detection) Efficiency shows you the percentage of VAD efficiency. It is displayed only for DSPM/FX interfaces. A value of 0 indicates that this parameter is not available." ::= { cdx6500PPSTVoicePortEntry 51} cdx6500VoiceStatsMeanDelayDeviation OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This parameter shows you Mean Delay Deviation. It is displayed only for DSPM/FX interfaces. A value of 0 indicates that this parameter is not available." ::= { cdx6500PPSTVoicePortEntry 52} cdx6500VoiceStatsMaxDelayDeviation OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This parameter shows you Max Delay Deviation in the way of Max Delay Deviation/Max Delay Dev Highwater. It is displayed only for DSPM/FX interfaces. A value of 0 indicates that this parameter is not available." ::= { cdx6500PPSTVoicePortEntry 53} cdx6500VoiceStatsPktRecResync OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This parameter shows you Receiver Resets. It is displayed only for DSPM/FX interfaces. A value of 0 indicates that this parameter is not available." ::= { cdx6500PPSTVoicePortEntry 54} cdx6500VoiceCallStatsNoPacketDropped OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "It is the number of dropped packet occurred during the last 24 hours." ::= { cdx6500PPSTVoicePortEntry 55} cdx6500VoiceCallStatsNoCallsDropped OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "It is the number of dropped calls occurred during the last 24 hours." ::= { cdx6500PPSTVoicePortEntry 56} cdx6500VoiceCallStatsDroppedReason0 OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "It is the number of dropped cause code 0, [originated by DTE; no info], upto the last 24 hours." ::= { cdx6500PPSTVoicePortEntry 57} cdx6500VoiceCallStatsDroppedReason1 OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "It is the number of dropped cause code 1, [number busy], upto the last 24 hours." ::= { cdx6500PPSTVoicePortEntry 58} cdx6500VoiceCallStatsDroppedReason3 OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "It is the number of dropped cause code 3, [invalid facility request], upto the last 24 hours." ::= { cdx6500PPSTVoicePortEntry 59} cdx6500VoiceCallStatsDroppedReason5 OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "It is the number of dropped cause code 5, [network congestion], upto the last 24 hours." ::= { cdx6500PPSTVoicePortEntry 60} cdx6500VoiceCallStatsDroppedReason9 OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "It is the number of dropped cause code 9, [out of order], upto the last 24 hours." ::= { cdx6500PPSTVoicePortEntry 61} cdx6500VoiceCallStatsDroppedReason11 OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "It is the number of dropped cause code 11, [access barred], upto the last 24 hours." ::= { cdx6500PPSTVoicePortEntry 62} cdx6500VoiceCallStatsDroppedReason13 OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "It is the number of dropped cause code 13, [not obtainable], upto the last 24 hours." ::= { cdx6500PPSTVoicePortEntry 63} cdx6500VoiceCallStatsDroppedReason17 OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "It is the number of dropped cause code 17, [remote procedure error], upto the last 24 hours." ::= { cdx6500PPSTVoicePortEntry 64} cdx6500VoiceCallStatsDroppedReason19 OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "It is the number of dropped cause code 19, [local procedure error], upto the last 24 hours." ::= { cdx6500PPSTVoicePortEntry 65} cdx6500VoiceCallStatsDroppedReason21 OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "It is the number of dropped cause code 21, [RPOA out of order], upto the last 24 hours." ::= { cdx6500PPSTVoicePortEntry 66} cdx6500VoiceCallStatsDroppedReason33 OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "It is the number of dropped cause code 33, [incompatible destination], upto the last 24 hours." ::= { cdx6500PPSTVoicePortEntry 67} cdx6500VoiceCallStatsDroppedReason-Rest OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "It is the number of the rest of dropped cause codes upto the last 24 hours." ::= { cdx6500PPSTVoicePortEntry 68} -- Signaling Sequence Trap Table cdx6500PPSTSignalingSequenceTrapTable OBJECT-TYPE SYNTAX SEQUENCE OF Cdx6500PPSTSignalingSequenceTrapEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table containing the Signaling Sequence Trap entries." ::= { cdx6500PSTVoicePortTable 2 } cdx6500PPSTSignalingSequenceTrapEntry OBJECT-TYPE SYNTAX Cdx6500PPSTSignalingSequenceTrapEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the Signaling Sequence Trap table." INDEX { cdx6500SignalingSequenceTrapPortNumber, cdx6500SignalingSequenceTrapEventNumber } ::= { cdx6500PPSTSignalingSequenceTrapTable 1 } Cdx6500PPSTSignalingSequenceTrapEntry ::= SEQUENCE { cdx6500SignalingSequenceTrapPortNumber INTEGER, cdx6500SignalingSequenceTrapEventNumber INTEGER, cdx6500SignalingSequenceTrapTxState DisplayString, cdx6500SignalingSequenceTrapRxState DisplayString, cdx6500SignalingSequenceTrapMachineState DisplayString, cdx6500SignalingSequenceTrapTimeSinceLastChange INTEGER, cdx6500SignalingSequenceTrapComment DisplayString } cdx6500SignalingSequenceTrapPortNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Port number of the Voice Port." ::= { cdx6500PPSTSignalingSequenceTrapEntry 1 } cdx6500SignalingSequenceTrapEventNumber OBJECT-TYPE SYNTAX INTEGER (1..32) ACCESS read-only STATUS mandatory DESCRIPTION "Event number in the Signaling Sequence Trap Entry." ::= { cdx6500PPSTSignalingSequenceTrapEntry 2 } cdx6500SignalingSequenceTrapTxState OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The transmitting voice signalling state is displayed as ABCD (i.e. 1010)." ::= { cdx6500PPSTSignalingSequenceTrapEntry 3 } cdx6500SignalingSequenceTrapRxState OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The receiving voice signalling state is displayed as ABCD (i.e. 1010)." ::= { cdx6500PPSTSignalingSequenceTrapEntry 4 } cdx6500SignalingSequenceTrapMachineState OBJECT-TYPE SYNTAX DisplayString (SIZE (11)) ACCESS read-only STATUS mandatory DESCRIPTION "The voice signalling state machine state is a 11 character field representing the state of the signalling software." ::= { cdx6500PPSTSignalingSequenceTrapEntry 5 } cdx6500SignalingSequenceTrapTimeSinceLastChange OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This parameter indicates the time from the previous state to this state, measured in milliseconds." ::= { cdx6500PPSTSignalingSequenceTrapEntry 6 } cdx6500SignalingSequenceTrapComment OBJECT-TYPE SYNTAX DisplayString (SIZE (0..16)) ACCESS read-only STATUS mandatory DESCRIPTION "The comment field is an ASCII string upto 16 characters long." ::= { cdx6500PPSTSignalingSequenceTrapEntry 7 } -- VCS (Voice Call Stats ) cdx6500StatVCSTable OBJECT-TYPE SYNTAX SEQUENCE OF Cdx6500StatVCSEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table is showing the Voice Call Statistics in a node that would allow a user to determine current and past perfrmance." ::= { cdx6500StatNetworkSvcsGroup 4} cdx6500StatVCSEntry OBJECT-TYPE SYNTAX Cdx6500StatVCSEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of objects describing a single VCS." INDEX { cdx6500StatVCSIndex} ::= { cdx6500StatVCSTable 1} Cdx6500StatVCSEntry ::= SEQUENCE { cdx6500StatVCSIndex INTEGER, cdx6500StatVCSTime DisplayString, cdx6500StatVCSNoPacketDropped INTEGER, cdx6500StatVCSNoCallsDropped INTEGER, cdx6500StatVCSDroppedReasons DisplayString, cdx6500StatVCSNoCallsProcessed INTEGER, cdx6500StatVCSPercentPeakAvgCurOfCPULoad DisplayString, cdx6500StatVCSPercentPeakAvgCurOfDataBuf DisplayString, cdx6500StatVCSPercentPeakAvgCurOfIORBBuf DisplayString } cdx6500StatVCSIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "It is time position in the list of VCS's." ::= { cdx6500StatVCSEntry 1 } cdx6500StatVCSTime OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "It is displaying the corresponding time to index in the list of VCS's." ::= { cdx6500StatVCSEntry 2 } cdx6500StatVCSNoPacketDropped OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "It is the number of dropped packet occurred during the time." ::= { cdx6500StatVCSEntry 3 } cdx6500StatVCSNoCallsDropped OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "It is the number of dropped calls occurred during the time." ::= { cdx6500StatVCSEntry 4 } cdx6500StatVCSDroppedReasons OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "It is the number of 12 possible reasons from x25-causes. (Rsn0/Rsn1/Rsn3/Rsn5/Rsn9/Rsn11/Rsn13/Rsn17/Rsn19/Rsn21/Rsn33/Rsn-Rest)" ::= { cdx6500StatVCSEntry 5 } cdx6500StatVCSNoCallsProcessed OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "It is the number of all voice calls processed." ::= { cdx6500StatVCSEntry 6 } cdx6500StatVCSPercentPeakAvgCurOfCPULoad OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "It is the value of Peak, Average and Currentof CPU load in percent. (Peak/Avg/Cur)" ::= { cdx6500StatVCSEntry 7 } cdx6500StatVCSPercentPeakAvgCurOfDataBuf OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "It is the value of Peak, Average and Current of Data Buffer in percent. (Peak/Avg/Cur)" ::= { cdx6500StatVCSEntry 8 } cdx6500StatVCSPercentPeakAvgCurOfIORBBuf OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "It is the value of Peak, Average and Current of IORB Buffer in percent. (Peak/Avg/Cur)" ::= { cdx6500StatVCSEntry 9 } END