TPLINK-QOS-MIB DEFINITIONS ::= BEGIN IMPORTS OBJECT-TYPE,MODULE-IDENTITY FROM SNMPv2-SMI DisplayString FROM SNMPv2-TC ifIndex FROM RFC1213-MIB tplinkMgmt FROM TPLINK-MIB; tplinkQosMIB MODULE-IDENTITY LAST-UPDATED "201212130930Z" ORGANIZATION "TPLINK" CONTACT-INFO "www.tplink.com.cn" DESCRIPTION "Private MIB for system time configuration." REVISION "201212130930Z" DESCRIPTION "Initial version of this MIB module." ::= { tplinkMgmt 22 } tplinkQosMIBObjects OBJECT IDENTIFIER ::= { tplinkQosMIB 1 } tplinkQosNotifications OBJECT IDENTIFIER ::= { tplinkQosMIB 2 } tplinkQosBasicConfig OBJECT IDENTIFIER ::= {tplinkQosMIBObjects 1} tplinkQosScheduler OBJECT IDENTIFIER ::= {tplinkQosMIBObjects 2} tplinkQos8021p OBJECT IDENTIFIER ::= {tplinkQosMIBObjects 3} tplinkQosDSCP OBJECT IDENTIFIER ::= {tplinkQosMIBObjects 4} -- the qos basic config tpQosBasicConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF TpQosBasicConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of qos basic config entries. Here you can configure the port priority." ::= { tplinkQosBasicConfig 1 } tpQosBasicConfigEntry OBJECT-TYPE SYNTAX TpQosBasicConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry contains of the information of qos basic config." INDEX { ifIndex } ::= { tpQosBasicConfigTable 1 } TpQosBasicConfigEntry ::= SEQUENCE { tpQosBasicConfigPort DisplayString, tpQosBasicConfigPri INTEGER, tpQosBasicConfigLag OCTET STRING (SIZE (1..255)) } tpQosBasicConfigPort OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The physical port number of the switch. " ::= { tpQosBasicConfigEntry 1 } tpQosBasicConfigPri OBJECT-TYPE SYNTAX INTEGER{ cos0(0), cos1(1), cos2(2), cos3(3), cos4(4), cos5(5), cos6(6), cos7(7) } MAX-ACCESS read-write STATUS current DESCRIPTION "0. Cos0 1. Cos1 2. Cos2 3. Cos3 4. Cos4 5. Cos5 6. Cos6 7. Cos7 Specify the priority for the port." ::= { tpQosBasicConfigEntry 2 } tpQosBasicConfigLag OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "The LAG number which the port belongs to. " ::= { tpQosBasicConfigEntry 3 } tpQosSchedulerConfig OBJECT-TYPE SYNTAX INTEGER{ sp-mode(0), wrr-mode(1), sp-wrr-mode(2), equ-mode(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Here you can select the schedule mode for the switch. 0. SP-Mode: Strict-Priority Mode. In this mode, the queue with higher priority will occupy the whole bandwidth. Packets in the queue with lower priority are sent only when the queue with higher priority is empty. 1. WRR-Mode: Weight Round Robin Mode. In this mode, packets in all the queues are sent in order based on the weight value for each queue. You can also config the TC queues' weight with values 1-127. 2. SP+WRR-Mode: Strict-Priority + Weight Round Robin Mode. In this mode, this switch provides two scheduling groups, SP group and WRR group. Queues in SP group and WRR group are scheduled strictly based on strict-priority mode while the queues inside WRR group follow the WRR mode. In SP+WRR mode, the largest TC queue is in the SP group and the others belong to the WRR group and You can also config the TC queues' weight with values 0-127, value 0 means this TC queue is in SP group. In this way, when scheduling queues, the switch allows TC queues in SP group to occupy the whole bandwidth following the SP mode and the other TC queues in the WRR group will take up the bandwidth according to their ratio. 3. Equ-Mode: Equal-Mode. In this mode, all the queues occupy the bandwidth equally." ::= { tplinkQosScheduler 1 } -- the qos 8021p config tpQosSchedulerWeightTable OBJECT-TYPE SYNTAX SEQUENCE OF TpQosSchedulerWeightEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of the information of qos scheduler queue weight." ::= { tplinkQosScheduler 2 } tpQosSchedulerWeightEntry OBJECT-TYPE SYNTAX TpQosSchedulerWeightEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry contains of the information of qos scheduler queue weight config." INDEX { tpQosSchedulerTc } ::= { tpQosSchedulerWeightTable 1 } TpQosSchedulerWeightEntry ::= SEQUENCE { tpQosSchedulerTc INTEGER, tpQosSchedulerWeight INTEGER } tpQosSchedulerTc OBJECT-TYPE SYNTAX INTEGER{ tc0(0), tc1(1), tc2(2), tc3(3), tc4(4), tc5(5), tc6(6), tc7(7) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the priority level the packets go egress. The priority levels are labeled as TC." ::= { tpQosSchedulerWeightEntry 1 } tpQosSchedulerWeight OBJECT-TYPE SYNTAX INTEGER(0..127) MAX-ACCESS read-write STATUS current DESCRIPTION "Indecates the egress queue weight value. The value ranges from 0 to 127." ::= { tpQosSchedulerWeightEntry 2 } tpQos8021pTable OBJECT-TYPE SYNTAX SEQUENCE OF TpQos8021pEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of qos 8021p entries. Here you can configure 802.1P Priority." ::= { tplinkQos8021p 2 } tpQos8021pEntry OBJECT-TYPE SYNTAX TpQos8021pEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry contains of the information of qos 8021p." INDEX { tpQos8021pPriTag } ::= { tpQos8021pTable 1 } TpQos8021pEntry ::= SEQUENCE { tpQos8021pPriTag INTEGER, tpQos8021pPriLevel INTEGER } tpQos8021pPriTag OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the precedence level defined by IEEE802.1P. " ::= { tpQos8021pEntry 1 } tpQos8021pPriLevel OBJECT-TYPE SYNTAX INTEGER{ tc0(0), tc1(1), tc2(2), tc3(3), tc4(4), tc5(5), tc6(6), tc7(7) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the priority level the packets with tag are mapped to. The priority levels are labeled as TC." ::= { tpQos8021pEntry 2 } -- the qos dscp config tpQosDSCPEnable OBJECT-TYPE SYNTAX INTEGER{ disable(0), enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "0. disable 1. enable Here you can enable or disable DSCP Priority." ::= { tplinkQosDSCP 1 } tpQosDSCPTable OBJECT-TYPE SYNTAX SEQUENCE OF TpQosDSCPEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of qos DSCP entries. Here you can configure DSCP Priority." ::= { tplinkQosDSCP 2 } tpQosDSCPEntry OBJECT-TYPE SYNTAX TpQosDSCPEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry contains of the information of qos DSCP." INDEX { tpQosDSCPPriTag } ::= { tpQosDSCPTable 1 } TpQosDSCPEntry ::= SEQUENCE { tpQosDSCPPriTag INTEGER, tpQosDSCPPriLevel INTEGER } tpQosDSCPPriTag OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the priority determined by the DS region of IP datagram. It ranges from 0 to 63. " ::= { tpQosDSCPEntry 1 } tpQosDSCPPriLevel OBJECT-TYPE SYNTAX INTEGER{ cos0(0), cos1(1), cos2(2), cos3(3), cos4(4), cos5(5), cos6(6), cos7(7) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the priority level the packets with tag are mapped to. The priority levels are labeled as cos0 - cos7." ::= { tpQosDSCPEntry 2 } END