TPLINK-8021X-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, IpAddress FROM SNMPv2-SMI tplinkMgmt FROM TPLINK-MIB ifIndex FROM RFC1213-MIB DisplayString FROM SNMPv2-TC; tplink8021xMIB MODULE-IDENTITY LAST-UPDATED "201212171050Z" ORGANIZATION "TPLINK" CONTACT-INFO "www.tplink.com.cn" DESCRIPTION "Private MIB for 802.1x configuration." REVISION "201212171050Z" DESCRIPTION "Initial version of this MIB module." ::= { tplinkMgmt 31 } tplink8021xMIBObjects OBJECT IDENTIFIER ::= { tplink8021xMIB 1 } tplink8021xNotifications OBJECT IDENTIFIER ::= { tplink8021xMIB 2 } tp8021xGlobalConfig OBJECT IDENTIFIER ::= {tplink8021xMIBObjects 1} tp8021xGlobalEnable OBJECT-TYPE SYNTAX INTEGER{ disable(0), enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "0. disable 1. enable Enable/Disable the 802.1X function." ::= { tp8021xGlobalConfig 1 } tp8021xAuthMode OBJECT-TYPE SYNTAX INTEGER{ pap(0), eap(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Select the Authentication Method 0. pap: IEEE 802.1X authentication system uses extensible authentication protocol (EAP) to exchange information between the switch and the client. The transmission of EAP packets is terminated at the switch and the EAP packets are converted to the other protocol (such as RADIUS) packets for transmission. 1. eap: IEEE 802.1X authentication system uses extensible authentication protocol (EAP) to exchange information between the switch and the client. The EAP protocol packets with authentication data can be encapsulated in the advanced protocol (such as RADIUS) packets to be transmitted to the authentication server." ::= { tp8021xGlobalConfig 2 } tp8021xHandshake OBJECT-TYPE SYNTAX INTEGER{ disable(0), enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "0. disable 1. enable Enable/Disable the handshake feature." ::= { tp8021xGlobalConfig 3 } tp8021xGuestVlanEnable OBJECT-TYPE SYNTAX INTEGER{ disable(0), enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "0. disable 1. enable Enable/Disable the Guest VLAN feature." ::= { tp8021xGlobalConfig 4 } tp8021xGuestVlanID OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Enter your desired VLAN ID to enable the Guest VLAN feature. The supplicants in the Guest VLAN can access the specified network source." ::= { tp8021xGlobalConfig 5 } tp8021xQuietEnable OBJECT-TYPE SYNTAX INTEGER{ disable(0), enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "0. disable 1. enable Enable/Disable the Quiet timer." ::= { tp8021xGlobalConfig 6 } tp8021xQuietPeriod OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Specify a value for Quiet Period. Once the supplicant failed to the 802.1X Authentication, then the switch will not respond to the authentication request from the same supplicant during the Quiet Period. (1-999 second)" ::= { tp8021xGlobalConfig 7 } tp8021xRetryTimes OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Specify the maximum transfer times of the repeated authentication request.(1-9)" ::= { tp8021xGlobalConfig 8 } tp8021xSupplicantTimeOut OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Specify the maximum time for the switch to wait for the response from supplicant before resending a request to the supplicant. (1-9 second)" ::= { tp8021xGlobalConfig 9 } tp8021xServerTimeOut OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Specify the maximum time for the switch to wait for the response from authentication server before resending a request to the authentication server. (1-9 second)" ::= { tp8021xGlobalConfig 10 } tp8021xAuthPrimaryIP OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Enter the IP address of the authentication server." ::= { tp8021xGlobalConfig 11 } tp8021xAuthSecondaryIP OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Enter the IP address of the alternate authentication server." ::= { tp8021xGlobalConfig 12 } tp8021xServerAuthPort OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Set the UDP port of authentication server(s). The default port is 1812(1-65535)" ::= { tp8021xGlobalConfig 13 } tp8021xServerAuthKey OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..255)) MAX-ACCESS read-write STATUS current DESCRIPTION "Set the shared password for the switch and the authentication servers to exchange messages.(0-31 characters)." ::= { tp8021xGlobalConfig 14 } tp8021xAcctEnable OBJECT-TYPE SYNTAX INTEGER{ disable(0), enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "0. disable 1. enable Enable/Disable the accounting feature. " ::= { tp8021xGlobalConfig 15 } tp8021xAcctPrimaryIP OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Enter the IP address of the accounting server." ::= { tp8021xGlobalConfig 16 } tp8021xAcctSecondaryIP OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Enter the IP address of the alternate accounting server." ::= { tp8021xGlobalConfig 17 } tp8021xAcctPort OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Set the UDP port of accounting server(s). The default port is 1813(1-65535)" ::= { tp8021xGlobalConfig 18 } tp8021xAcctKey OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..255)) MAX-ACCESS read-write STATUS current DESCRIPTION "Set the shared password for the switch and the accounting servers to exchange messages. (0-31 characters)." ::= { tp8021xGlobalConfig 19 } -- the 8021x port config tp8021xPortConfig OBJECT IDENTIFIER ::= {tplink8021xMIBObjects 2} tp8021xPortConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF TP8021XPORTCONFIGENTRY MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of 8021x port config entries." ::= { tp8021xPortConfig 1 } tp8021xPortConfigEntry OBJECT-TYPE SYNTAX TP8021XPORTCONFIGENTRY MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry contains of the information of 8021x port config. Here you can configure the ports for the 802.1X authentication." INDEX { ifIndex } ::= { tp8021xPortConfigTable 1 } TP8021XPORTCONFIGENTRY ::= SEQUENCE { tp8021xPortConfigPortIndex DisplayString, tp8021xPortConfigEnable INTEGER, tp8021xPortConfigGuestVlanEnable INTEGER, tp8021xPortConfigControlMode INTEGER, tp8021xPortConfigControlType INTEGER, tp8021xPortConfigAuthState INTEGER, tp8021xPortConfigPortLag OCTET STRING } tp8021xPortConfigPortIndex OBJECT-TYPE SYNTAX DisplayString(SIZE(0..16)) MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the port number." ::= {tp8021xPortConfigEntry 1} tp8021xPortConfigEnable OBJECT-TYPE SYNTAX INTEGER{ disable(0), enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "0. disable 1. enable Select Enable/Disable the 802.1X authentication feature for the port." ::= { tp8021xPortConfigEntry 2 } tp8021xPortConfigGuestVlanEnable OBJECT-TYPE SYNTAX INTEGER{ disable(0), enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "0. disable 1. enable Select Enable/Disable the Guest VLAN feature for the port." ::= { tp8021xPortConfigEntry 3 } tp8021xPortConfigControlMode OBJECT-TYPE SYNTAX INTEGER{ forceAuth(0), forceUnAuth(1), autoAuth(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Specify the Control Mode for the port. 0. force auth: In this mode, the port can work normally without passing the 802.1X Authentication. 1. force unauth: In this mode, the port is forbidden working for its fixed unauthorized status. 2. auto auth: In this mode, the port will normally work only after passing the 802.1X Authentication." ::= { tp8021xPortConfigEntry 4 } tp8021xPortConfigControlType OBJECT-TYPE SYNTAX INTEGER{ macBased(0), portBased(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Specify the Control Type for the port. 0. base of mac: Any client connected to the port should pass the 802.1X Authentication for access. 1. base of port: All the clients connected to the port can access the network on the condition that any one of the clients has passed the 802.1X Authentication. " ::= { tp8021xPortConfigEntry 5 } tp8021xPortConfigAuthState OBJECT-TYPE SYNTAX INTEGER{ unAuthorized(0), authorized(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "The authentication status of the port. 0. unAuthorized 1. Authorized" ::= { tp8021xPortConfigEntry 6 } tp8021xPortConfigPortLag OBJECT-TYPE SYNTAX OCTET STRING(SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "the lag the port belong to" ::= { tp8021xPortConfigEntry 7 } END