TIMESTEP-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, Counter32, Integer32, enterprises FROM SNMPv2-SMI DateAndTime, TimeStamp FROM SNMPv2-TC; timestep MODULE-IDENTITY LAST-UPDATED "9810210000Z" ORGANIZATION "Newbridge Corporation" CONTACT-INFO " Newbridge Corporation 362 Terry Fox Drive Kanata, ON K0A 2H0 Canada 1-800-383-8211 tsupport@newbridge.com" DESCRIPTION "The MIB module to describe local system information of the Newbridge Permit family of IPSEC Gates." REVISION "9810210000Z" DESCRIPTION "Initial revision." ::= { enterprises 1022 } permitGate OBJECT IDENTIFIER ::= { timestep 9 } permitGateSerialNumber OBJECT-TYPE SYNTAX OCTET STRING (SIZE (12)) MAX-ACCESS read-only STATUS current DESCRIPTION "The device serial number." ::= { permitGate 1 } permitGateCpuUtilInst OBJECT-TYPE SYNTAX INTEGER(0..100) MAX-ACCESS read-only STATUS current DESCRIPTION "The instantaneous CPU utilization." ::= { permitGate 2 } permitGateCpuUtilAvg1Min OBJECT-TYPE SYNTAX INTEGER(0..100) MAX-ACCESS read-only STATUS current DESCRIPTION "The one minute average of CPU utilization." ::= { permitGate 3 } permitGateCpuUtilAvg5Min OBJECT-TYPE SYNTAX INTEGER(0..100) MAX-ACCESS read-only STATUS current DESCRIPTION "The five minutes average of CPU utilization." ::= { permitGate 4 } permitGateLastConfigModifTime OBJECT-TYPE SYNTAX TimeStamp MAX-ACCESS read-only STATUS current DESCRIPTION "Time since boot that the last configuration modification occured. If the configuration has not changed, then the value is 0." ::= { permitGate 5 } permitGateTotalRebootNum OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of times the machine has been rebooted." ::= { permitGate 6 } permitGateTotalVolMemory OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total amount of volatile memory on the device in bytes." ::= { permitGate 7 } permitGateFreeVolMemory OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total amount of free volatile memory on the device in bytes." ::= { permitGate 8 } permitGateEncDevStatus OBJECT-TYPE SYNTAX INTEGER { up(0), down(1), notApplicable(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The encryption device status." ::= { permitGate 9 } permitGateRandNumGenStatus OBJECT-TYPE SYNTAX INTEGER { up(0), down(1), notApplicable(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The random number generator status." ::= { permitGate 10 } permitGateCertExpDate OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "The device's certificate expiration date." ::= { permitGate 11 } permitGateIfArpTable OBJECT-TYPE SYNTAX SEQUENCE OF PermitGateIfArpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The (conceptual) table containing information about the Permit/Gate interface entries" ::= { permitGate 12 } permitGateIfArpEntry OBJECT-TYPE SYNTAX PermitGateIfArpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry (conceptual row) containing on a particuliar Permit/Gate interface" INDEX { permitGateIfArpIndex } ::= { permitGateIfArpTable 1 } PermitGateIfArpEntry ::= SEQUENCE { permitGateIfArpIndex Integer32, permitGateIfArpInPkts Counter32, permitGateIfArpOutPkts Counter32, permitGateIfArpInOctets Counter32, permitGateIfArpOutOctets Counter32 } permitGateIfArpIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A unique value, greater than zero for each interface." ::= { permitGateIfArpEntry 1 } permitGateIfArpInPkts OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Arp protocol input packet count" ::= { permitGateIfArpEntry 2 } permitGateIfArpOutPkts OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Arp protocol output packet count" ::= { permitGateIfArpEntry 3 } permitGateIfArpInOctets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Arp protocol input octet count" ::= { permitGateIfArpEntry 4 } permitGateIfArpOutOctets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Arp protocol output octet count" ::= { permitGateIfArpEntry 5 } END