-- file automatically created TELDAT-TRAP-FRBK-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY,OBJECT-TYPE,OBJECT-IDENTITY,NOTIFICATION-TYPE,Integer32,IpAddress FROM SNMPv2-SMI DisplayString FROM SNMPv2-TC telEventTraps FROM TELDAT-MIB; frbkTrapsMIB MODULE-IDENTITY LAST-UPDATED "201401200930Z" ORGANIZATION "Teldat, S.A." CONTACT-INFO "Teldat, S.A. Customer Service Postal: Parque Tecnologico de Madrid Tres Cantos 28760 Madrid, SPAIN Tel.: +34 918 076 565 http://www.teldat.com" DESCRIPTION "This Module Information Base file is defined for managing received SNMP notifications generated by the FRBK event subsystem." REVISION "201401200930Z" DESCRIPTION "Initial implementation" ::= { telEventTraps 114 } frbkEventsGroup OBJECT IDENTIFIER ::= { frbkTrapsMIB 1 } frbkNotifications OBJECT IDENTIFIER ::= { frbkTrapsMIB 2 } frbkNotificationsPrefix OBJECT IDENTIFIER ::= { frbkNotifications 0 } frbkEventObjects1 OBJECT-IDENTITY STATUS current DESCRIPTION "Event FRBK.1 A PVC switched to backup state." ::= { frbkEventsGroup 1 } frbk1-circuit OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'circuit' in event FRBK.1" ::= { frbkEventObjects1 1 } frbk1-ifc-name OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'ifc-name' in event FRBK.1" ::= { frbkEventObjects1 2 } frbkEventObjects2 OBJECT-IDENTITY STATUS current DESCRIPTION "Event FRBK.2 A PVC returns from backup state to active state." ::= { frbkEventsGroup 2 } frbk2-circuit OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'circuit' in event FRBK.2" ::= { frbkEventObjects2 1 } frbk2-ifc-name OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'ifc-name' in event FRBK.2" ::= { frbkEventObjects2 2 } frbkEventObjects3 OBJECT-IDENTITY STATUS current DESCRIPTION "Event FRBK.3 All PVCs in backup state are forced to return to active state whenever it is possible." ::= { frbkEventsGroup 3 } frbk3-ifc-name OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'ifc-name' in event FRBK.3" ::= { frbkEventObjects3 1 } frbkEventObjects4 OBJECT-IDENTITY STATUS current DESCRIPTION "Event FRBK.4 When backup timer expires all circuits can switch to normal operation (if it is possible)." ::= { frbkEventsGroup 4 } frbk4-ifc-name OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'ifc-name' in event FRBK.4" ::= { frbkEventObjects4 1 } frbkEventObjects5 OBJECT-IDENTITY STATUS current DESCRIPTION "Event FRBK.5 All traffic which normally goes through Frame Relay interface must be routered through the associated backup interface over ISDN." ::= { frbkEventsGroup 5 } frbk5-ifc-name OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'ifc-name' in event FRBK.5" ::= { frbkEventObjects5 1 } frbk5-isdn-ifc-name OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'isdn-ifc-name' in event FRBK.5" ::= { frbkEventObjects5 2 } frbkEventObjects6 OBJECT-IDENTITY STATUS current DESCRIPTION "Event FRBK.6 Frame Relay interface (primary link) has recovered: it is active and operative again, so the secondary link automatically disconnects and traffic stops being transmitted through the ISDN backup interface." ::= { frbkEventsGroup 6 } frbk6-ifc-name OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'ifc-name' in event FRBK.6" ::= { frbkEventObjects6 1 } frbk6-isdn-ifc-name OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'isdn-ifc-name' in event FRBK.6" ::= { frbkEventObjects6 2 } frbkEventObjects7 OBJECT-IDENTITY STATUS current DESCRIPTION "Event FRBK.7 A PVC switched to backup state." ::= { frbkEventsGroup 7 } frbk7-circuit OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'circuit' in event FRBK.7" ::= { frbkEventObjects7 1 } frbk7-ifc-name OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'ifc-name' in event FRBK.7" ::= { frbkEventObjects7 2 } frbk7-isdn-ifc-name OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'isdn-ifc-name' in event FRBK.7" ::= { frbkEventObjects7 3 } frbkEventObjects8 OBJECT-IDENTITY STATUS current DESCRIPTION "Event FRBK.8 A PVC returns from backup state to active state." ::= { frbkEventsGroup 8 } frbk8-circuit OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'circuit' in event FRBK.8" ::= { frbkEventObjects8 1 } frbk8-ifc-name OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'ifc-name' in event FRBK.8" ::= { frbkEventObjects8 2 } frbk8-isdn-ifc-name OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'isdn-ifc-name' in event FRBK.8" ::= { frbkEventObjects8 3 } frbkNotification1 NOTIFICATION-TYPE OBJECTS { frbk1-circuit, frbk1-circuit, frbk1-ifc-name } STATUS current DESCRIPTION "Notification of Event FRBK.1 Message: 'Backup-PVC, PVC=$1 PVCBackup=$2, on interface $3' Parameters list: $1: frbk1-circuit $2: frbk1-circuit $3: frbk1-ifc-name A PVC switched to backup state." ::= { frbkNotificationsPrefix 1 } frbkNotification2 NOTIFICATION-TYPE OBJECTS { frbk2-circuit, frbk2-circuit, frbk2-ifc-name } STATUS current DESCRIPTION "Notification of Event FRBK.2 Message: 'Return Backup-PVC, PVC=$1 PVCBackup= $2, on interface $3' Parameters list: $1: frbk2-circuit $2: frbk2-circuit $3: frbk2-ifc-name A PVC returns from backup state to active state." ::= { frbkNotificationsPrefix 2 } frbkNotification3 NOTIFICATION-TYPE OBJECTS { frbk3-ifc-name } STATUS current DESCRIPTION "Notification of Event FRBK.3 Message: 'Return command Backup PVC, on interface $1' Parameters list: $1: frbk3-ifc-name All PVCs in backup state are forced to return to active state whenever it is possible." ::= { frbkNotificationsPrefix 3 } frbkNotification4 NOTIFICATION-TYPE OBJECTS { frbk4-ifc-name } STATUS current DESCRIPTION "Notification of Event FRBK.4 Message: 'Tiemout Backup PVC, on interface $1' Parameters list: $1: frbk4-ifc-name When backup timer expires all circuits can switch to normal operation (if it is possible)." ::= { frbkNotificationsPrefix 4 } frbkNotification5 NOTIFICATION-TYPE OBJECTS { frbk5-ifc-name, frbk5-isdn-ifc-name } STATUS current DESCRIPTION "Notification of Event FRBK.5 Message: 'ISDN Backup, FR interface $1, RDSI interface $2' Parameters list: $1: frbk5-ifc-name $2: frbk5-isdn-ifc-name All traffic which normally goes through Frame Relay interface must be routered through the associated backup interface over ISDN." ::= { frbkNotificationsPrefix 5 } frbkNotification6 NOTIFICATION-TYPE OBJECTS { frbk6-ifc-name, frbk6-isdn-ifc-name } STATUS current DESCRIPTION "Notification of Event FRBK.6 Message: 'Return ISDN Backup, FR interface $1, RDSI interface $2' Parameters list: $1: frbk6-ifc-name $2: frbk6-isdn-ifc-name Frame Relay interface (primary link) has recovered: it is active and operative again, so the secondary link automatically disconnects and traffic stops being transmitted through the ISDN backup interface." ::= { frbkNotificationsPrefix 6 } frbkNotification7 NOTIFICATION-TYPE OBJECTS { frbk7-circuit, frbk7-circuit, frbk7-ifc-name, frbk7-isdn-ifc-name } STATUS current DESCRIPTION "Notification of Event FRBK.7 Message: 'ISDN Backup, PVC=$1 PVCBackup-ISDN=$2, FR interface $3 RDSI interface $4' Parameters list: $1: frbk7-circuit $2: frbk7-circuit $3: frbk7-ifc-name $4: frbk7-isdn-ifc-name A PVC switched to backup state." ::= { frbkNotificationsPrefix 7 } frbkNotification8 NOTIFICATION-TYPE OBJECTS { frbk8-circuit, frbk8-circuit, frbk8-ifc-name, frbk8-isdn-ifc-name } STATUS current DESCRIPTION "Notification of Event FRBK.8 Message: 'Return ISDN-Backup, PVC=$1 PVCBackup-ISDN = $2, FR interface $3 RDSI interface $4' Parameters list: $1: frbk8-circuit $2: frbk8-circuit $3: frbk8-ifc-name $4: frbk8-isdn-ifc-name A PVC returns from backup state to active state." ::= { frbkNotificationsPrefix 8 } END