-- Teldat, S.A. -- Parque Tecnolgico de Madrid -- 28760, Tres Cantos (Madrid) -- Tlf: +34-918076565 -- Fax: +34-918076521 -- e-mail: id@teldat.com -- MIB privada de Teldat -- MIB privada de monitorizacin de los interfaces Frame Relay -- Historial: -- 07/02/14 M.A. Pastor XH 3523. Errors with HP Openview 9.20 -- 1.3 08/07/09 I. Muoz Revisin de todas las MIB para evitar -- M.A. Pastor warnings y errores de compilacin -- 1.2 13/11/08 P. Nogueira Tablas de llamadas obsoletas -- 1.1 25/11/04 M.A. Pastor La introduccin del HSSI provoca que -- las lneas puedan alcanzar velocidades -- de 50 Mbps -- 1.0 01/07/04 J. Molina Archivo procedente de FR.MIB -- Historial de FR.MIB: -- 01-10-01 N.Villaseor Traduccin a ingles -- 01-12-00 M.A. Pastor Modificaciones para que pueda ser -- compilada utilizando compiladores -- distintos del de Teldat -- 27-01-00 M.A. Pastor Implementacion inicial -------------------------------------------------------------------------------- TELDAT-MON-INTERF-FR-MIB DEFINITIONS ::= BEGIN IMPORTS IpAddress, Counter FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 DisplayString FROM RFC1213-MIB telProdNpMonInterfRouter FROM TELDAT-SW-STRUCTURE-MIB; telProdNpMonInterfFR OBJECT IDENTIFIER ::= { telProdNpMonInterfRouter 9 } -- Grupo telProdNpMonInterfFR -- Incluye los parmetros referentes a los interfaces Frame Relay sobre linea -- serie, a los FR-Dial y al encapsulado FR de los interfaces Frame Relay -- sobre RDSI. -- Tabla de datos generales de los interfaces Frame Relay. Esta tabla no aparece -- en el caso de interfaces FR sobre RDSI ni FR-Dial: slo est disponible en el -- caso de FR sobre lnea serie. -- Habr una entrada en la tabla por cada interfaz, y en cada entrada se -- muestran los datos que dan informacin sobre el tipo de interfaz sobre el que -- corre FR (DCE o DTE), la velocidad de lnea y cundo se realiz el ultimo -- reset del puerto. telProdNpMonInterfFRGlobalTable OBJECT-TYPE SYNTAX SEQUENCE OF TelProdNpMonInterfFRGlobalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of general information about interfaces Frame Relay. This information is not available for FR-Dial or FR over RDSI interfaces. The entry number is determined by the interface value." ::= { telProdNpMonInterfFR 1 } telProdNpMonInterfFRGlobalEntry OBJECT-TYPE SYNTAX TelProdNpMonInterfFRGlobalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry consists of the interface number of the node, that is the table index, the interface type or physical driver (DTE o DCE) used by Frame Relay, the line speed and the time the last port reset was performed." INDEX { telProdNpMonInterfFRGloIndex } ::= { telProdNpMonInterfFRGlobalTable 1 } TelProdNpMonInterfFRGlobalEntry ::= SEQUENCE { telProdNpMonInterfFRGloIndex INTEGER, telProdNpMonInterfFRGloDriverType DisplayString, telProdNpMonInterfFRGloLineSpeed INTEGER, telProdNpMonInterfFRGloLastResetWeek INTEGER, telProdNpMonInterfFRGloLastResetDay INTEGER, telProdNpMonInterfFRGloLastResetHour INTEGER, telProdNpMonInterfFRGloLastResetMin INTEGER, telProdNpMonInterfFRGloLastResetSec INTEGER } telProdNpMonInterfFRGloIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Node interface number, that indicates the table entry (table index)." ::= { telProdNpMonInterfFRGlobalEntry 1 } telProdNpMonInterfFRGloDriverType OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "FR interface type: (1) DCE, (2) DTE." ::= { telProdNpMonInterfFRGlobalEntry 2 } telProdNpMonInterfFRGloLineSpeed OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Line data rate, expressed in bits per second. The value 0 indicates unknown speed." ::= { telProdNpMonInterfFRGlobalEntry 3 } telProdNpMonInterfFRGloLastResetWeek OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Weeks passed since the last port reset." ::= { telProdNpMonInterfFRGlobalEntry 4 } telProdNpMonInterfFRGloLastResetDay OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Days passed since the last port reset: spare days after counting weeks, that do not form a complete week, that means the variable value will be always lower than 7." ::= { telProdNpMonInterfFRGlobalEntry 5 } telProdNpMonInterfFRGloLastResetHour OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Hours passed since the last port reset. If more than a week has passed, this variable indicates the number hours to add to the number of weeks and days, and its value will be lower than 24 so a complete day can't be formed." ::= { telProdNpMonInterfFRGlobalEntry 6 } telProdNpMonInterfFRGloLastResetMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Minutes passed since the last port reset. This variable indicates the number of minutes since the last hour was added to the hour counter." ::= { telProdNpMonInterfFRGlobalEntry 7 } telProdNpMonInterfFRGloLastResetSec OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Seconds passed since the last port reset. The total time passed will be the addition of weeks, days, hours, minutes and seconds since the last reset." ::= { telProdNpMonInterfFRGlobalEntry 8 } -- Tabla de los circuitos RS232. Esta tabla da informacin acerca de si -- las seales RTS, CTS, DSR, DTR, DCD, RI y LL estn activas o no. No est -- presente en el caso de interfaces FR-Dial o FR sobre RDSI. telProdNpMonInterfFRRS232Table OBJECT-TYPE SYNTAX SEQUENCE OF TelProdNpMonInterfFRRS232Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of RS232 signals or circuits. It shows if the corresponding signal is active. This table does not exist for FR-Dial or FR over ISDN interfaces. The entry number is determined by the interface value." ::= { telProdNpMonInterfFR 2 } telProdNpMonInterfFRRS232Entry OBJECT-TYPE SYNTAX TelProdNpMonInterfFRRS232Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry consists of the node interface number, that is the table index, the order number of the circuit in that interface (second index), that goes between 1 and a maximum number that depends on the connector type (maximum 7), the circuit number (105, 106, 107, 108, 109, 125, 141), its name (RTS, CTS, DSR, DTR, DCD, RI, LL) and if it is active or not." INDEX { telProdNpMonInterfFRRS232Index, telProdNpMonInterfFRRS232CircIndex } ::= { telProdNpMonInterfFRRS232Table 1 } TelProdNpMonInterfFRRS232Entry ::= SEQUENCE { telProdNpMonInterfFRRS232Index INTEGER, telProdNpMonInterfFRRS232CircIndex INTEGER, telProdNpMonInterfFRRS232Circuit INTEGER, telProdNpMonInterfFRRS232Nickname DisplayString, telProdNpMonInterfFRRS232State DisplayString } telProdNpMonInterfFRRS232Index OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Node interface number. It is the first table index." ::= { telProdNpMonInterfFRRS232Entry 1 } telProdNpMonInterfFRRS232CircIndex OBJECT-TYPE SYNTAX INTEGER(1..7) ACCESS read-only STATUS mandatory DESCRIPTION "Second table index. It is a number that goes between 1 and the maximum number of this type of circuits, that varies with the connector." ::= { telProdNpMonInterfFRRS232Entry 2 } telProdNpMonInterfFRRS232Circuit OBJECT-TYPE SYNTAX INTEGER(105..141) ACCESS read-only STATUS mandatory DESCRIPTION "RS232 circuit number." ::= { telProdNpMonInterfFRRS232Entry 3 } telProdNpMonInterfFRRS232Nickname OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Circuit name." ::= { telProdNpMonInterfFRRS232Entry 4 } telProdNpMonInterfFRRS232State OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Signal (of the circuits) status: on, off or unknown." ::= { telProdNpMonInterfFRRS232Entry 5 } -- Tabla de los contadores de las tramas de salida y de errores en las tramas -- de entrada. Esta informacin no est disponible si se trata de interfaces -- FR-Dial o FR sobre RDSI. telProdNpMonInterfFRFramesTable OBJECT-TYPE SYNTAX SEQUENCE OF TelProdNpMonInterfFRFramesEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of counters of output frames and errors on input frames. This information is not available for FR-Dial or FR over ISDN interfaces. The entry number is determined by the interface (table index)." ::= { telProdNpMonInterfFR 3 } telProdNpMonInterfFRFramesEntry OBJECT-TYPE SYNTAX TelProdNpMonInterfFRFramesEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry consists of the node interface number, which is the table index, a variable that shows the output of the last table delete attempt (get operation) or performs the delete operation (set operation), CRC errors in incoming frames, alignment errors, lost incoming frames due to overrun, too long frames, aborted frames, number of errors due to DMA/FIFO overrun, number of DMA/FIFO underrun in outgoing frames and aborted outputs sent." INDEX { telProdNpMonInterfFRFramesIndex } ::= { telProdNpMonInterfFRFramesTable 1 } TelProdNpMonInterfFRFramesEntry ::= SEQUENCE { telProdNpMonInterfFRFramesIndex INTEGER, telProdNpMonInterfFRFramesClear INTEGER, telProdNpMonInterfFRFramesCRCError Counter, telProdNpMonInterfFRFramesMissed Counter, telProdNpMonInterfFRFramesAborted Counter, telProdNpMonInterfFRFramesAlignment Counter, telProdNpMonInterfFRFramesTooLong Counter, telProdNpMonInterfFRFramesOverrun Counter, telProdNpMonInterfFRFramesUnderrun Counter, telProdNpMonInterfFRFramesTxAbort Counter } telProdNpMonInterfFRFramesIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Node interface number, which shows the corresponding table entry (it is the table index)." ::= { telProdNpMonInterfFRFramesEntry 1 } telProdNpMonInterfFRFramesClear OBJECT-TYPE SYNTAX INTEGER{ delete(1), ok(2), error(3), undefined(4) } ACCESS read-write STATUS mandatory DESCRIPTION "This variable when is read shows the output from the last table delete attempt: the value is 2 if the deletion was performed succesfully, 3 if an error ocurred and 4 for an undefined result, that means that nobody has tried to delete the table yet. In set operations, the value 1 (it is the only value that can be assigned by a writing operation) causes a table deletion: frame counters are set to 0." ::= { telProdNpMonInterfFRFramesEntry 2 } telProdNpMonInterfFRFramesCRCError OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames with CRC errors." ::= { telProdNpMonInterfFRFramesEntry 3 } telProdNpMonInterfFRFramesMissed OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of incoming frames lost due to overrun." ::= { telProdNpMonInterfFRFramesEntry 4 } telProdNpMonInterfFRFramesAborted OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of incoming frames aborted." ::= { telProdNpMonInterfFRFramesEntry 5 } telProdNpMonInterfFRFramesAlignment OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of incoming frames with alignment errors." ::= { telProdNpMonInterfFRFramesEntry 6 } telProdNpMonInterfFRFramesTooLong OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of too long incoming frames." ::= { telProdNpMonInterfFRFramesEntry 7 } telProdNpMonInterfFRFramesOverrun OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of DMA/FIFO overrun." ::= { telProdNpMonInterfFRFramesEntry 8 } telProdNpMonInterfFRFramesUnderrun OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of DMA/FIFO overrun." ::= { telProdNpMonInterfFRFramesEntry 9 } telProdNpMonInterfFRFramesTxAbort OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of aborted outputs sent." ::= { telProdNpMonInterfFRFramesEntry 10 } -- Grupo de compresin. Aqu se incluyen todas las variables que dan informacin -- sobre la compresin, organizadas en tres tablas: la tabla de los estadsicos -- de compresin, la tabla del comienzo de cuenta de estos estadsicos y el -- grupo de la versin de compresin. telProdNpMonInterfFRCompGroup OBJECT IDENTIFIER ::= { telProdNpMonInterfFR 4 } -- La primera de las tablas dentro del grupo de compresin es la tabla de los -- estadsicos, que contiene informacin sobre el numero de interfaz de que se -- trata y el numero de dlci para el que se sacan los estadsicos de compresin -- (son los dos ndices con que se recorre esta tabla), una variable para -- indicar el borrado de estadsicos, y los contadores de bytes y tramas -- gestionados/as, procesados/as, no procesados/as, tramas errneas y tramas -- fuera de secuencia, y esto tanto en compresin como en descompresin. No -- aparece si es un interfaz FR-Dial (no est hecha la monitorizacin de este -- tipo de interfaces en el Nucleox-Plus). telProdNpMonInterfFRCompStatTable OBJECT-TYPE SYNTAX SEQUENCE OF TelProdNpMonInterfFRCompStatEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains compression statistics of Frame Relay, FR-Dial and FR over ISDN interfaces. The entry number is determined by the interface value (first table index) and the dlci number whose statistics want to be got (second table index)." ::= { telProdNpMonInterfFRCompGroup 1 } telProdNpMonInterfFRCompStatEntry OBJECT-TYPE SYNTAX TelProdNpMonInterfFRCompStatEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry consists of the interface number, which is the first table index, the dlci number whose statistics are of interest (second index), a variable that shows the output of the last table delete attempt (get operation) or performs the delete operation (set operation), and the current output from managed, processed and non processed bytes and frames counters, error frames counters and out of sequence in compression and decompression frames counter." INDEX { telProdNpMonInterfFRCStatIfcIndex, telProdNpMonInterfFRCStatDlciIndex } ::= { telProdNpMonInterfFRCompStatTable 1 } TelProdNpMonInterfFRCompStatEntry ::= SEQUENCE { telProdNpMonInterfFRCStatIfcIndex INTEGER, telProdNpMonInterfFRCStatDlciIndex INTEGER, telProdNpMonInterfFRCStatClear INTEGER, telProdNpMonInterfFRCStatManFrComp Counter, telProdNpMonInterfFRCStatManByComp Counter, telProdNpMonInterfFRCStatProcFrComp Counter, telProdNpMonInterfFRCStatProcByComp Counter, telProdNpMonInterfFRCStatNotProcFrComp Counter, telProdNpMonInterfFRCStatNotProcByComp Counter, telProdNpMonInterfFRCStatErrorFrComp Counter, telProdNpMonInterfFRCStatOutSeqFrComp Counter, telProdNpMonInterfFRCStatManFrDecomp Counter, telProdNpMonInterfFRCStatManByDecomp Counter, telProdNpMonInterfFRCStatProcFrDecomp Counter, telProdNpMonInterfFRCStatProcByDecomp Counter, telProdNpMonInterfFRCStatNotProcFrDecomp Counter, telProdNpMonInterfFRCStatNotProcByDecomp Counter, telProdNpMonInterfFRCStatErrorFrDecomp Counter, telProdNpMonInterfFRCStatOutSeqFrDecomp Counter } telProdNpMonInterfFRCStatIfcIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Node interface number. It is the first table index." ::= { telProdNpMonInterfFRCompStatEntry 1 } telProdNpMonInterfFRCStatDlciIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Dlci number in the interface. It is the second table index." ::= { telProdNpMonInterfFRCompStatEntry 2 } telProdNpMonInterfFRCStatClear OBJECT-TYPE SYNTAX INTEGER{ delete(1), ok(2), error(3), undefined(4) } ACCESS read-write STATUS mandatory DESCRIPTION "This variable when is read shows the output from the last table delete attempt: the value is 2 if the deletion was performed succesfully, 3 if an error ocurred and 4 for an undefined result, that means that nobody has tried to delete the table yet. In set operations, the value 1 (it is the only value that can be assigned by a writing operation) causes a table deletion: frame counters are set to 0." ::= { telProdNpMonInterfFRCompStatEntry 3 } telProdNpMonInterfFRCStatManFrComp OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames managed in compression." ::= { telProdNpMonInterfFRCompStatEntry 4 } telProdNpMonInterfFRCStatManByComp OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of bytes managed in compression." ::= { telProdNpMonInterfFRCompStatEntry 5 } telProdNpMonInterfFRCStatProcFrComp OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames processed in compression." ::= { telProdNpMonInterfFRCompStatEntry 6 } telProdNpMonInterfFRCStatProcByComp OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of bytes processed in compression." ::= { telProdNpMonInterfFRCompStatEntry 7 } telProdNpMonInterfFRCStatNotProcFrComp OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames not processed in compression." ::= { telProdNpMonInterfFRCompStatEntry 8 } telProdNpMonInterfFRCStatNotProcByComp OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of bytes not processed in compression." ::= { telProdNpMonInterfFRCompStatEntry 9 } telProdNpMonInterfFRCStatErrorFrComp OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames with errors in compression." ::= { telProdNpMonInterfFRCompStatEntry 10 } telProdNpMonInterfFRCStatOutSeqFrComp OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames out of sequence in compression." ::= { telProdNpMonInterfFRCompStatEntry 11 } telProdNpMonInterfFRCStatManFrDecomp OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames managed in decompression." ::= { telProdNpMonInterfFRCompStatEntry 12 } telProdNpMonInterfFRCStatManByDecomp OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of bytes managed in decompression." ::= { telProdNpMonInterfFRCompStatEntry 13 } telProdNpMonInterfFRCStatProcFrDecomp OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames processed in decompression." ::= { telProdNpMonInterfFRCompStatEntry 14 } telProdNpMonInterfFRCStatProcByDecomp OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of bytes processed in decompression." ::= { telProdNpMonInterfFRCompStatEntry 15 } telProdNpMonInterfFRCStatNotProcFrDecomp OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames not processed in decompression." ::= { telProdNpMonInterfFRCompStatEntry 16 } telProdNpMonInterfFRCStatNotProcByDecomp OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of bytes not processed in decompression." ::= { telProdNpMonInterfFRCompStatEntry 17 } telProdNpMonInterfFRCStatErrorFrDecomp OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames with errors in decompression." ::= { telProdNpMonInterfFRCompStatEntry 18 } telProdNpMonInterfFRCStatOutSeqFrDecomp OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames out of sequence in decompression." ::= { telProdNpMonInterfFRCompStatEntry 19 } -- Tabla de informacin del comienzo de cuenta de los estadsicos de -- compresin. Las variables en ella contenidas indican los componentes de -- la fecha y hora en que comenz la cuenta de estadsicos. No aparece si el -- interfaz es un FR-Dial. telProdNpMonInterfFRCStatBeginTable OBJECT-TYPE SYNTAX SEQUENCE OF TelProdNpMonInterfFRCStatBeginEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains compression statistics of Frame Relay, FR-Dial and FR over ISDN interfaces. The entry number is determined by the interface value (table index)." ::= { telProdNpMonInterfFRCompGroup 2 } telProdNpMonInterfFRCStatBeginEntry OBJECT-TYPE SYNTAX TelProdNpMonInterfFRCStatBeginEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry consists of the node interface number, that is the table index, and a variable for each component of the time and date when the statistic counting began." INDEX { telProdNpMonInterfFRCStatBeginInterfIndex } ::= { telProdNpMonInterfFRCStatBeginTable 1 } TelProdNpMonInterfFRCStatBeginEntry ::= SEQUENCE { telProdNpMonInterfFRCStatBeginInterfIndex INTEGER, telProdNpMonInterfFRCStatBeginDay INTEGER, telProdNpMonInterfFRCStatBeginMonth INTEGER, telProdNpMonInterfFRCStatBeginYear INTEGER, telProdNpMonInterfFRCStatBeginHour INTEGER, telProdNpMonInterfFRCStatBeginMin INTEGER, telProdNpMonInterfFRCStatBeginSec INTEGER } telProdNpMonInterfFRCStatBeginInterfIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Node interface number, that indicates the table entry (table index)." ::= { telProdNpMonInterfFRCStatBeginEntry 1 } telProdNpMonInterfFRCStatBeginDay OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Beginning day of the counting of compression statistics." ::= { telProdNpMonInterfFRCStatBeginEntry 2 } telProdNpMonInterfFRCStatBeginMonth OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Beginning month of the counting of compression statistics." ::= { telProdNpMonInterfFRCStatBeginEntry 3 } telProdNpMonInterfFRCStatBeginYear OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Beginning year of the counting of compression statistics." ::= { telProdNpMonInterfFRCStatBeginEntry 4 } telProdNpMonInterfFRCStatBeginHour OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Beginning hour of the counting of compression statistics." ::= { telProdNpMonInterfFRCStatBeginEntry 5 } telProdNpMonInterfFRCStatBeginMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Beginning minute of the counting of compression statistics." ::= { telProdNpMonInterfFRCStatBeginEntry 6 } telProdNpMonInterfFRCStatBeginSec OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Beginning second of the counting of compression statistics." ::= { telProdNpMonInterfFRCStatBeginEntry 7 } -- Grupo de la versin de compresin. Es comn para todos los interfaces -- Frame Relay y Frame Relay sobre RDSI (no aparece si es Frame Relay Dial). telProdNpMonInterfFRCompVersGroup OBJECT IDENTIFIER ::= { telProdNpMonInterfFRCompGroup 3 } telProdNpMonInterfFRCompVersRevision OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Revision." ::= { telProdNpMonInterfFRCompVersGroup 1 } telProdNpMonInterfFRCompVersCard OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Card." ::= { telProdNpMonInterfFRCompVersGroup 2 } telProdNpMonInterfFRCompVersInterruptMode OBJECT-TYPE SYNTAX INTEGER{ active(1), inactive(2) } ACCESS read-only STATUS mandatory DESCRIPTION "It indicates if the Interruption Mode is active (1) or inactive (2)." ::= { telProdNpMonInterfFRCompVersGroup 3 } -- Tabla de los estadsicos de compresin CRTP. Incluye, para un dlci de un -- interfaz Frame Relay o FR sobre RDSI, una variable que indica el resultado de -- la ultima operacin de borrado si se accede a ella con un get, y mediante -- un set de esta variable se procede al borrado de los estadsicos de -- esta tabla, y tambien contadores de paquetes RTP salientes detectados, -- paquetes RTP salientes comprimidos, numero de bsquedas del estado de la -- conexin, numero de veces que no se encontr el estado de la conexin, -- numero de paquetes RTP entrantes no comprimidos, numero de paquetes RTP -- entrantes comprimidos, numero de paquetes RTP entrantes desconocidos y -- numero de paquetes RTP tipo Context State. telProdNpMonInterfFRCrtpTable OBJECT-TYPE SYNTAX SEQUENCE OF TelProdNpMonInterfFRCrtpEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of statistics of CRTP compression of Frame Relay, FR-Dial and FR over RDSI interfaces. The entry number is determined by the interface value (first table index) and the dlci number for the interface of which we want to obtain the statistics (second index)." ::= { telProdNpMonInterfFR 5 } telProdNpMonInterfFRCrtpEntry OBJECT-TYPE SYNTAX TelProdNpMonInterfFRCrtpEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry consists of the node interface number, which is the table index, the dlci number for the interface of which we want to obtain the statistics (second index),a variable that shows the output of the last table delete attempt (get operation) or performs the delete operation (set operation), and the current output from the counters of outgoing detected RTP packets, outgoing compressed RTP packets, number of searchs of the connection status, number of times the connection status was not found, number of incoming non compressed RTP packets, number of incoming compressed RTP packets, number of incoming unknown RTP packets and number of Context State RTP packets." INDEX { telProdNpMonInterfFRCrtpIfcIndex, telProdNpMonInterfFRCrtpDlciIndex } ::= { telProdNpMonInterfFRCrtpTable 1 } TelProdNpMonInterfFRCrtpEntry ::= SEQUENCE { telProdNpMonInterfFRCrtpIfcIndex INTEGER, telProdNpMonInterfFRCrtpDlciIndex INTEGER, telProdNpMonInterfFRCrtpClear INTEGER, telProdNpMonInterfFRCrtpOutRTPPack Counter, telProdNpMonInterfFRCrtpOutRTPComp Counter, telProdNpMonInterfFRCrtpSearchConn Counter, telProdNpMonInterfFRCrtpNoFindConn Counter, telProdNpMonInterfFRCrtpInRTPunCom Counter, telProdNpMonInterfFRCrtpInRTPComp Counter, telProdNpMonInterfFRCrtpInUnknownType Counter, telProdNpMonInterfFRCrtpContexStatePack Counter } telProdNpMonInterfFRCrtpIfcIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Node interface number. It is the first table index." ::= { telProdNpMonInterfFRCrtpEntry 1 } telProdNpMonInterfFRCrtpDlciIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Dlci number of the interface. It is the second table index." ::= { telProdNpMonInterfFRCrtpEntry 2 } telProdNpMonInterfFRCrtpClear OBJECT-TYPE SYNTAX INTEGER{ delete(1), ok(2), error(3), undefined(4) } ACCESS read-write STATUS mandatory DESCRIPTION "This variable when is read shows the output from the last table delete attempt: the value is 2 if the deletion was performed succesfully, 3 if an error ocurred and 4 for an undefined result, that means that nobody has tried to delete the table yet. In set operations, the value 1 (it is the only value that can be assigned by a writing operation) causes a table deletion: frame counters are set to 0." ::= { telProdNpMonInterfFRCrtpEntry 3 } telProdNpMonInterfFRCrtpOutRTPPack OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of detected outgoing RTP packets." ::= { telProdNpMonInterfFRCrtpEntry 4 } telProdNpMonInterfFRCrtpOutRTPComp OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of compressed outgoing RTP packets" ::= { telProdNpMonInterfFRCrtpEntry 5 } telProdNpMonInterfFRCrtpSearchConn OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of searchs of the connection status." ::= { telProdNpMonInterfFRCrtpEntry 6 } telProdNpMonInterfFRCrtpNoFindConn OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of times the connection status was not found." ::= { telProdNpMonInterfFRCrtpEntry 7 } telProdNpMonInterfFRCrtpInRTPunCom OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of non compressed incoming RTP packets." ::= { telProdNpMonInterfFRCrtpEntry 8 } telProdNpMonInterfFRCrtpInRTPComp OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of compressed incoming RTP packets." ::= { telProdNpMonInterfFRCrtpEntry 9 } telProdNpMonInterfFRCrtpInUnknownType OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of unknown incoming RTP packets." ::= { telProdNpMonInterfFRCrtpEntry 10 } telProdNpMonInterfFRCrtpContexStatePack OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of Context State RTP packets." ::= { telProdNpMonInterfFRCrtpEntry 11 } -- Tabla de LMI (Local Management). La informacin en ella incluida slo aparece -- en el caso de interfaces Frame Relay o Frame Relay sobre RDSI. telProdNpMonInterfFRLmiTable OBJECT-TYPE SYNTAX SEQUENCE OF TelProdNpMonInterfFRLmiEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "LMI table. The entry number is determined by the interface value." ::= { telProdNpMonInterfFR 6 } telProdNpMonInterfFRLmiEntry OBJECT-TYPE SYNTAX TelProdNpMonInterfFRLmiEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry consists of the node interface number, that is the table index, a variable that shows the output from the last statistics delete attempt, another variable shows if the LMI management is enabled, the dlci associated to that management, the LMI type, if orphan circuits are allowed, the LMI sequence interval (in seconds), line access rate (bps), the Interface MTU (Maximum Transmission Unit) (in bytes), CIR monitor adjustment, Timer T1 (in seconds), counter N1 increments, LMI N2 error threshold, LMI N3 error window, IR percentage increment, IR percentage decrement, point to point line enabled or not and the point to point DLCI used in this case, protocol broadcast enabled or not, emulate multicast enabled or not for the active PVCs, congestion monitoring enabled or not, CIR monitoring that limits the router transmission speed active or inactive, a variable used to enable the inmediate return of Frame Relay back-up that only allows set operations, number of received sequence, number of transmitted sequence, total number of link status requests and responses to these requests, total number of sequence requests and number of responses to sequence requests." INDEX { telProdNpMonInterfFRLmiIndex } ::= { telProdNpMonInterfFRLmiTable 1 } TelProdNpMonInterfFRLmiEntry ::= SEQUENCE { telProdNpMonInterfFRLmiIndex INTEGER, telProdNpMonInterfFRLmiClearStat INTEGER, telProdNpMonInterfFRLmiHab INTEGER, telProdNpMonInterfFRLmiDlci INTEGER, telProdNpMonInterfFRLmiType INTEGER, telProdNpMonInterfFRLmiOrphans INTEGER, telProdNpMonInterfFRLmiSecInterv INTEGER, telProdNpMonInterfFRLmiLineAccRate INTEGER, telProdNpMonInterfFRLmiMTU INTEGER, telProdNpMonInterfFRLmiCIRAdjust INTEGER, telProdNpMonInterfFRLmiT1 INTEGER, telProdNpMonInterfFRLmiN1 INTEGER, telProdNpMonInterfFRLmiN2 INTEGER, telProdNpMonInterfFRLmiN3 INTEGER, telProdNpMonInterfFRLmiIRIncr INTEGER, telProdNpMonInterfFRLmiIRDecr INTEGER, telProdNpMonInterfFRLmiIRMin INTEGER, telProdNpMonInterfFRLmiPTPLine INTEGER, telProdNpMonInterfFRLmiPTPDlci INTEGER, telProdNpMonInterfFRLmiProtBroad INTEGER, telProdNpMonInterfFRLmiEmuMulticast INTEGER, telProdNpMonInterfFRLmiCongMonit INTEGER, telProdNpMonInterfFRLmiCIRMonit INTEGER, telProdNpMonInterfFRLmiEnabPVCBkupRetTime INTEGER, telProdNpMonInterfFRLmiCurrentRcvSeq INTEGER, telProdNpMonInterfFRLmiCurrentTxSeq INTEGER, telProdNpMonInterfFRLmiTotStatusEnq Counter, telProdNpMonInterfFRLmiTotStatusResp Counter, telProdNpMonInterfFRLmiTotSeqReq Counter, telProdNpMonInterfFRLmiTotSeqResp Counter } telProdNpMonInterfFRLmiIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Node interface number, that shows the corresponding table entry (table index)." ::= { telProdNpMonInterfFRLmiEntry 1 } telProdNpMonInterfFRLmiClearStat OBJECT-TYPE SYNTAX INTEGER{ delete(1), ok(2), error(3), undefined(4) } ACCESS read-write STATUS mandatory DESCRIPTION "This variable when is read shows the output from the last table delete attempt: the value is 2 if the deletion was performed succesfully, 3 if an error ocurred and 4 for an undefined result, that means that nobody has tried to delete the table yet. In set operations, the value 1 (it is the only value that can be assigned by a writing operation) causes a table deletion: frame counters are set to 0." ::= { telProdNpMonInterfFRLmiEntry 2 } telProdNpMonInterfFRLmiHab OBJECT-TYPE SYNTAX INTEGER{ enabled(1), disabled(2) } ACCESS read-only STATUS mandatory DESCRIPTION "LMI enabled or disabled: it shows if Frame Relay management is active (1) or inactive (2)." ::= { telProdNpMonInterfFRLmiEntry 3 } telProdNpMonInterfFRLmiDlci OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "LMI DLCI: Management circuit number. It will be 0(ANSI, CCITT) or 1023(LMI)." ::= { telProdNpMonInterfFRLmiEntry 4 } telProdNpMonInterfFRLmiType OBJECT-TYPE SYNTAX INTEGER{ disabled-lmi(0), ccitt(1), ansi(2), lmi(3) } ACCESS read-only STATUS mandatory DESCRIPTION "LMI Type: (1) CCITT, (2) ANSI T.1 617 Annex D, (3) LMI Rev.1. If LMI is not enabled this variable takes the value 0 (disabled-lmi)." ::= { telProdNpMonInterfFRLmiEntry 5 } telProdNpMonInterfFRLmiOrphans OBJECT-TYPE SYNTAX INTEGER{ yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates if all non configured circuits made known by management are available for use, yes or no." ::= { telProdNpMonInterfFRLmiEntry 6 } telProdNpMonInterfFRLmiSecInterv OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the sequence interval that LMI management uses (in seconds)." ::= { telProdNpMonInterfFRLmiEntry 7 } telProdNpMonInterfFRLmiLineAccRate OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Physical data rate of the Frame Relay interface in bits per second." ::= { telProdNpMonInterfFRLmiEntry 8 } telProdNpMonInterfFRLmiMTU OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "MTU (maximum transmission unit) of the Frame Relay interface in bytes." ::= { telProdNpMonInterfFRLmiEntry 9 } telProdNpMonInterfFRLmiCIRAdjust OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "CIR monitor adjustment." ::= { telProdNpMonInterfFRLmiEntry 10 } telProdNpMonInterfFRLmiT1 OBJECT-TYPE SYNTAX INTEGER(5..30) ACCESS read-only STATUS mandatory DESCRIPTION "Timer T1, in seconds." ::= { telProdNpMonInterfFRLmiEntry 11 } telProdNpMonInterfFRLmiN1 OBJECT-TYPE SYNTAX INTEGER(1..255) ACCESS read-only STATUS mandatory DESCRIPTION "Counter N1 increments." ::= { telProdNpMonInterfFRLmiEntry 12 } telProdNpMonInterfFRLmiN2 OBJECT-TYPE SYNTAX INTEGER(1..10) ACCESS read-only STATUS mandatory DESCRIPTION "Allowable errors N2." ::= { telProdNpMonInterfFRLmiEntry 13 } telProdNpMonInterfFRLmiN3 OBJECT-TYPE SYNTAX INTEGER(1..10) ACCESS read-only STATUS mandatory DESCRIPTION "Error window N3." ::= { telProdNpMonInterfFRLmiEntry 14 } telProdNpMonInterfFRLmiIRIncr OBJECT-TYPE SYNTAX INTEGER(1..100) ACCESS read-write STATUS mandatory DESCRIPTION "IR adjustment percentage increment." DEFVAL{ 12 } ::= { telProdNpMonInterfFRLmiEntry 15 } telProdNpMonInterfFRLmiIRDecr OBJECT-TYPE SYNTAX INTEGER(1..100) ACCESS read-write STATUS mandatory DESCRIPTION "IR adjustment percentage decrement." DEFVAL{ 25 } ::= { telProdNpMonInterfFRLmiEntry 16 } telProdNpMonInterfFRLmiIRMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Minimum IR as CIR percentage." DEFVAL{ 25 } ::= { telProdNpMonInterfFRLmiEntry 17 } telProdNpMonInterfFRLmiPTPLine OBJECT-TYPE SYNTAX INTEGER{ yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Point to point line enabled (1) or not (2)." ::= { telProdNpMonInterfFRLmiEntry 18 } telProdNpMonInterfFRLmiPTPDlci OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Point to point dlci: used when the net is configured as point to point." ::= { telProdNpMonInterfFRLmiEntry 19 } telProdNpMonInterfFRLmiProtBroad OBJECT-TYPE SYNTAX INTEGER{ yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Broadcast Protocol : Yes (1) or No (2)." ::= { telProdNpMonInterfFRLmiEntry 20 } telProdNpMonInterfFRLmiEmuMulticast OBJECT-TYPE SYNTAX INTEGER{ yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Emulate Multicast: it shows if multicast emulation is enabled on each active PVC, yes (1) or no(2)." ::= { telProdNpMonInterfFRLmiEntry 21 } telProdNpMonInterfFRLmiCongMonit OBJECT-TYPE SYNTAX INTEGER{ yes(1), no(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Congestion Monitoring: congestion monitoring feature. The variable value may be (1) if it is enabled congestion monitoring or (2) if not." ::= { telProdNpMonInterfFRLmiEntry 22 } telProdNpMonInterfFRLmiCIRMonit OBJECT-TYPE SYNTAX INTEGER{ yes(1), no(2) } ACCESS read-write STATUS mandatory DESCRIPTION "FR CIR monitoring: indicates whether the circuit monitoring feature that enforces the transmission rate is enabled, yes (1) or no (2)." ::= { telProdNpMonInterfFRLmiEntry 23 } telProdNpMonInterfFRLmiEnabPVCBkupRetTime OBJECT-TYPE SYNTAX INTEGER{ enable-prompt-return-from-PVC-back-up(1), ok(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable the prompt return from the PVC back-up. This variable only makes sense in a set operation (value 1). It can be enabled, but not disabled. In a read operation we will get the value 2 (ok)." ::= { telProdNpMonInterfFRLmiEntry 24 } telProdNpMonInterfFRLmiCurrentRcvSeq OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Sequence number received." ::= { telProdNpMonInterfFRLmiEntry 25 } telProdNpMonInterfFRLmiCurrentTxSeq OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Sequence number transmitted." ::= { telProdNpMonInterfFRLmiEntry 26 } telProdNpMonInterfFRLmiTotStatusEnq OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of link status inquiries." ::= { telProdNpMonInterfFRLmiEntry 27 } telProdNpMonInterfFRLmiTotStatusResp OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of link status responses." ::= { telProdNpMonInterfFRLmiEntry 28 } telProdNpMonInterfFRLmiTotSeqReq OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of sequence requests." ::= { telProdNpMonInterfFRLmiEntry 29 } telProdNpMonInterfFRLmiTotSeqResp OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of sequence responses." ::= { telProdNpMonInterfFRLmiEntry 30 } -- Tabla de informacin sobre los PVCs (PVC Status). Contiene el numero de PVCs -- permitidos, configurados, activos, congestionados, incorporados (join net) -- y dejados (left net). Esta tabla slo aparece si se trata de un interfaz -- Frame Relay o Frame Relay sobre RDSI. telProdNpMonInterfFRPvcStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF TelProdNpMonInterfFRPvcStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of PVC Status. The entry is determined by the interface number. It gives information about the number of allowable PVCs, configured PVCs, active PVCs, congested PVCs, PVCs that have joined the network and PVCs that are no longer on the network." ::= { telProdNpMonInterfFR 7 } telProdNpMonInterfFRPvcStatusEntry OBJECT-TYPE SYNTAX TelProdNpMonInterfFRPvcStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry consists of the number of the node interface that is the table index, a variable to delete the table (in get operations shows the output from the last attempt for deleting counters of congested circuits, joined and left, and the set operation begins to delete counters), and the number of allowed PVCs, configured PVCs, active PVCs, congested PVCs, left PVCs (left net) and joined PVCs (join net)." INDEX { telProdNpMonInterfFRPvcStaIfcIndex } ::= { telProdNpMonInterfFRPvcStatusTable 1 } TelProdNpMonInterfFRPvcStatusEntry ::= SEQUENCE { telProdNpMonInterfFRPvcStaIfcIndex INTEGER, telProdNpMonInterfFRPvcStaClear INTEGER, telProdNpMonInterfFRPvcStaTotAllow INTEGER, telProdNpMonInterfFRPvcStaTotConfig INTEGER, telProdNpMonInterfFRPvcStaTotActiv INTEGER, telProdNpMonInterfFRPvcStaTotCong INTEGER, telProdNpMonInterfFRPvcStaTotLeftNet INTEGER, telProdNpMonInterfFRPvcStaTotJoinNet INTEGER } telProdNpMonInterfFRPvcStaIfcIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of the node interface, that indicates the corresponding table entry (it is the table index)." ::= { telProdNpMonInterfFRPvcStatusEntry 1 } telProdNpMonInterfFRPvcStaClear OBJECT-TYPE SYNTAX INTEGER{ delete(1), ok(2), error(3), undefined(4) } ACCESS read-write STATUS mandatory DESCRIPTION "This variable when is read shows the output from the last table delete attempt: the value is 2 if the deletion was performed succesfully, 3 if an error ocurred and 4 for an undefined result, that means that nobody has tried to delete the table yet. When we perform a set operation with value 1, the counters of the congested, joined and left circuits are deleted." ::= { telProdNpMonInterfFRPvcStatusEntry 2 } telProdNpMonInterfFRPvcStaTotAllow OBJECT-TYPE SYNTAX INTEGER(0..992) ACCESS read-only STATUS mandatory DESCRIPTION "Number of allowable PVCs." ::= { telProdNpMonInterfFRPvcStatusEntry 3 } telProdNpMonInterfFRPvcStaTotConfig OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Total number of currently configured PVCs." ::= { telProdNpMonInterfFRPvcStatusEntry 4 } telProdNpMonInterfFRPvcStaTotActiv OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Total number of active PVCs." ::= { telProdNpMonInterfFRPvcStatusEntry 5 } telProdNpMonInterfFRPvcStaTotCong OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Total number of congested PVCs." ::= { telProdNpMonInterfFRPvcStatusEntry 6 } telProdNpMonInterfFRPvcStaTotLeftNet OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Total number of left PVCs (left net)." ::= { telProdNpMonInterfFRPvcStatusEntry 7 } telProdNpMonInterfFRPvcStaTotJoinNet OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Total number of joined PVCs (join net)." ::= { telProdNpMonInterfFRPvcStatusEntry 8 } -- Tabla de los PVCs. Contiene informacin sobre el estado del circuito (activo, -- inactivo, congestionado o eliminado), el tipo de circuito (permanente, -- conmutado o multicast), si es hurfano, si los datos por l transmitidos -- estn cifrados o no, numero de tramas y bytes transmitidos y recibidos, -- tramas transmitidas perdidas por desbordamiento de la cola, tramas perdidas -- por overrun en la entrada, total de FECNs, total de BECNs, numero de veces -- que el circuito se congestion, numero de veces que estuvo inactivo, CIR, -- VIR, Bc y Be del circuito. No estar disponible esta informacin si el -- interfaz en cuestin no es Frame Relay o Frame Relay sobre RDSI. telProdNpMonInterfFRPvcTable OBJECT-TYPE SYNTAX SEQUENCE OF TelProdNpMonInterfFRPvcEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of PVCs. The entry is determined by the interface number and the circuit number (dlci), that are the table index. It contains information about the circuit status (active, inactive, congested or removed), the type of circuit (permanent, switched or multicast), if the circuit is orphan, if transmitted data are encoded, number of frames and bytes transmitted and received, transmitted frames lost due to queue oveflow, frames lost due to input overrun, total number of FECNs, total number of BECNs, number of times the circuit congested, number of times the circuit was inactive, and circuit CIR, VIR, Bc and Be." ::= { telProdNpMonInterfFR 8 } telProdNpMonInterfFRPvcEntry OBJECT-TYPE SYNTAX TelProdNpMonInterfFRPvcEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry contains the number of node interface (first table index), the circuit number (dlci) (second index), a variable to delete the table (in get operations shows the output from the last attempt for deleting statistics, and the set operation begins to delete statistics), the circuit status (active, inactive, congested or removed), if the circuit is orphan, if transmitted data are encoded or not, number of frames and bytes transmitted and received, transmitted frames lost due to queue oveflow, frames lost due to input overrun, total number of FECNs, total number of BECNs, number of times the circuit congested, number of times the circuit was inactive, and circuit CIR, VIR, Bc and Be." INDEX { telProdNpMonInterfFRPvcIfcIndex, telProdNpMonInterfFRPvcDlciIndex } ::= { telProdNpMonInterfFRPvcTable 1 } TelProdNpMonInterfFRPvcEntry ::= SEQUENCE { telProdNpMonInterfFRPvcIfcIndex INTEGER, telProdNpMonInterfFRPvcDlciIndex INTEGER, telProdNpMonInterfFRPvcClearStatistics INTEGER, telProdNpMonInterfFRPvcName DisplayString, telProdNpMonInterfFRPvcCircStatus INTEGER, telProdNpMonInterfFRPvcCircType INTEGER, telProdNpMonInterfFRPvcOrphan INTEGER, telProdNpMonInterfFRPvcEncrypt INTEGER, telProdNpMonInterfFRPvcTxFrames INTEGER, telProdNpMonInterfFRPvcTxBytes INTEGER, telProdNpMonInterfFRPvcRcvFrames INTEGER, telProdNpMonInterfFRPvcRcvBytes INTEGER, telProdNpMonInterfFRPvcQueueOverf INTEGER, telProdNpMonInterfFRPvcOverrun INTEGER, telProdNpMonInterfFRPvcTotFECNs INTEGER, telProdNpMonInterfFRPvcTotBECNs INTEGER, telProdNpMonInterfFRPvcTimesCong INTEGER, telProdNpMonInterfFRPvcTimesInact INTEGER, telProdNpMonInterfFRPvcCIR INTEGER, telProdNpMonInterfFRPvcVIR INTEGER, telProdNpMonInterfFRPvcBc INTEGER, telProdNpMonInterfFRPvcBe INTEGER } telProdNpMonInterfFRPvcIfcIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of the node interface (it is the first table index)." ::= { telProdNpMonInterfFRPvcEntry 1 } telProdNpMonInterfFRPvcDlciIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Circuit number (dlci) for that interface (second table index)." ::= { telProdNpMonInterfFRPvcEntry 2 } telProdNpMonInterfFRPvcClearStatistics OBJECT-TYPE SYNTAX INTEGER{ delete(1), ok(2), error(3), undefined(4) } ACCESS read-write STATUS mandatory DESCRIPTION "This variable when is read shows the output from the last table delete attempt: the value is 2 if the deletion was performed succesfully, 3 if an error ocurred and 4 for an undefined result, that means that nobody has tried to delete the table yet. When we perform a set operation with value 1, the counters of PVCs statistics included in the table are deleted." ::= { telProdNpMonInterfFRPvcEntry 3 } telProdNpMonInterfFRPvcName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Circuit name." ::= { telProdNpMonInterfFRPvcEntry 4 } telProdNpMonInterfFRPvcCircStatus OBJECT-TYPE SYNTAX INTEGER{ inactive(1), active(2), congested(3), removed(4) } ACCESS read-write STATUS mandatory DESCRIPTION "Circuit state: (1) inactive (waiting in LMI), (2) active, (3) congested, (4) removed. If this field stores a value different from the previous ones (active, congested or removed), the circuit is considered inactive." ::= { telProdNpMonInterfFRPvcEntry 5 } telProdNpMonInterfFRPvcCircType OBJECT-TYPE SYNTAX INTEGER{ unknown(0), permanent(1), switched(2), multicast(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Type of circuit: (0) unknown, (1) permanent, (2) switched, (3) multicast." ::= { telProdNpMonInterfFRPvcEntry 6 } telProdNpMonInterfFRPvcOrphan OBJECT-TYPE SYNTAX INTEGER{ yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This variable indicates if the circuit is orphan, yes (1) or no (2)." ::= { telProdNpMonInterfFRPvcEntry 7 } telProdNpMonInterfFRPvcEncrypt OBJECT-TYPE SYNTAX INTEGER{ yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This variable indicates if data are encoded, yes (1) or no (2)." ::= { telProdNpMonInterfFRPvcEntry 8 } telProdNpMonInterfFRPvcTxFrames OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Transmitted frames." ::= { telProdNpMonInterfFRPvcEntry 9 } telProdNpMonInterfFRPvcTxBytes OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Transmitted bytes." ::= { telProdNpMonInterfFRPvcEntry 10 } telProdNpMonInterfFRPvcRcvFrames OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Received frames." ::= { telProdNpMonInterfFRPvcEntry 11 } telProdNpMonInterfFRPvcRcvBytes OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Received bytes." ::= { telProdNpMonInterfFRPvcEntry 12 } telProdNpMonInterfFRPvcQueueOverf OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Transmitted frames lost due to queue overflow." ::= { telProdNpMonInterfFRPvcEntry 13 } telProdNpMonInterfFRPvcOverrun OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Frames lost due to input overrun. This variable only makes sense if the interface is not FR over ISDN or FR-DIAL, or FR over ISDN is not enabled. In the previous cases, tha variable will take the value 0." ::= { telProdNpMonInterfFRPvcEntry 14 } telProdNpMonInterfFRPvcTotFECNs OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Total FECNs: number of times inbound congestion was notified." ::= { telProdNpMonInterfFRPvcEntry 15 } telProdNpMonInterfFRPvcTotBECNs OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Total BECNs: number of times outbound congestion was notified." ::= { telProdNpMonInterfFRPvcEntry 16 } telProdNpMonInterfFRPvcTimesCong OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of times the circuit became congested." ::= { telProdNpMonInterfFRPvcEntry 17 } telProdNpMonInterfFRPvcTimesInact OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of times this circuit was inoperable." ::= { telProdNpMonInterfFRPvcEntry 18 } telProdNpMonInterfFRPvcCIR OBJECT-TYPE SYNTAX INTEGER(300..52428800) ACCESS read-write STATUS mandatory DESCRIPTION "CIR (Committed Information Rate), en bps." ::= { telProdNpMonInterfFRPvcEntry 19 } telProdNpMonInterfFRPvcVIR OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "VIR (Current Information Rate)." ::= { telProdNpMonInterfFRPvcEntry 20 } telProdNpMonInterfFRPvcBc OBJECT-TYPE SYNTAX INTEGER(300..52428800) ACCESS read-write STATUS mandatory DESCRIPTION "Bc (Commited Burst Size), en bits." ::= { telProdNpMonInterfFRPvcEntry 21 } telProdNpMonInterfFRPvcBe OBJECT-TYPE SYNTAX INTEGER(0..52428800) ACCESS read-write STATUS mandatory DESCRIPTION "Be (Excess Burst Size)." ::= { telProdNpMonInterfFRPvcEntry 22 } -- Tabla de las direcciones de protocolo. Puesto que puede haber varias -- direcciones por protocolo e interfaz, sern necesarios tres ndices: -- el numero de interfaz, el tipo de protocolo y el numero de orden de -- la direccin. Adems de estas variables, aparecen la direccin de protocolo -- y el dlci asociado a esa direccin. Esta informacin no estar disponible si -- el interfaz no es Frame Relay o Frame Relay sobre RDSI. telProdNpMonInterfFRProtAddTable OBJECT-TYPE SYNTAX SEQUENCE OF TelProdNpMonInterfFRProtAddEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of protocol addresses. It contains information about the protocol type, the protocol address (it is possible to have several per protocol and interface) and the circuit number (dlci) associated to that address." ::= { telProdNpMonInterfFR 9 } telProdNpMonInterfFRProtAddEntry OBJECT-TYPE SYNTAX TelProdNpMonInterfFRProtAddEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry consists of the number of the interface (first table index), the protocol type (second index), the address order number (third index: it is necessary because it is possible to have several addresses associated to each protocol and interface), the protocol address and the dlci associated to that address." INDEX { telProdNpMonInterfFRProtAddIfcIndex, telProdNpMonInterfFRProtAddProtocIndex, telProdNpMonInterfFRProtAddOrdenIndex } ::= { telProdNpMonInterfFRProtAddTable 1 } TelProdNpMonInterfFRProtAddEntry ::= SEQUENCE { telProdNpMonInterfFRProtAddIfcIndex INTEGER, telProdNpMonInterfFRProtAddProtocIndex INTEGER, telProdNpMonInterfFRProtAddOrdenIndex INTEGER, telProdNpMonInterfFRProtAddAddress IpAddress, telProdNpMonInterfFRProtAddDlci INTEGER } telProdNpMonInterfFRProtAddIfcIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of the interface (first table index)." ::= { telProdNpMonInterfFRProtAddEntry 1 } telProdNpMonInterfFRProtAddProtocIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Protocol type (second table index)." ::= { telProdNpMonInterfFRProtAddEntry 2 } telProdNpMonInterfFRProtAddOrdenIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Address order number (it is possible to have several addresses associated to each protocol and interface). It is the third index." ::= { telProdNpMonInterfFRProtAddEntry 3 } telProdNpMonInterfFRProtAddAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "Protocol address." ::= { telProdNpMonInterfFRProtAddEntry 4 } telProdNpMonInterfFRProtAddDlci OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Dlci associated to that address." ::= { telProdNpMonInterfFRProtAddEntry 5 } -- Tabla de las llamadas activas. La tabla se recorre con ayuda de dos ndices: -- el numero del interfaz y la posicin u orden de la llamada en la tabla. -- Contiene informacin acerca del nombre y numero de dlci del circuito sobre el -- que se ha establecido la llamada, los numeros llamado y llamante, -- la referencia de la llamada y la hora, minuto y segundo en que dio comienzo -- la misma. Esta tabla no existe si no se trata de un interfaz Frame Relay -- o Frame Relay sobre RDSI. telProdNpMonInterfFRActCallsTable OBJECT-TYPE SYNTAX SEQUENCE OF TelProdNpMonInterfFRActCallsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of active calls. It contains information about the name and number (dlci) of the circuit through which the call is established, called and calling number, call reference and the hour, minute and second of the call beginning." ::= { telProdNpMonInterfFR 10 } telProdNpMonInterfFRActCallsEntry OBJECT-TYPE SYNTAX TelProdNpMonInterfFRActCallsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry contains the number of the node interface (first index), the order number of the call in the table (second index), name and dlci of the circuit through which the call is established, called and calling number, call reference and the hour, minute and second of the call beginning." INDEX { telProdNpMonInterfFRActCallsIfcIndex, telProdNpMonInterfFRActCallsOrdenIndex } ::= { telProdNpMonInterfFRActCallsTable 1 } TelProdNpMonInterfFRActCallsEntry ::= SEQUENCE { telProdNpMonInterfFRActCallsIfcIndex INTEGER, telProdNpMonInterfFRActCallsOrdenIndex INTEGER, telProdNpMonInterfFRActCallsCircuitName DisplayString, telProdNpMonInterfFRActCallsDlci INTEGER, telProdNpMonInterfFRActCallsCalledNum DisplayString, telProdNpMonInterfFRActCallsCallingNum DisplayString, telProdNpMonInterfFRActCallsRef INTEGER, telProdNpMonInterfFRActCallsStartHour INTEGER, telProdNpMonInterfFRActCallsStartMin INTEGER, telProdNpMonInterfFRActCallsStartSec INTEGER } telProdNpMonInterfFRActCallsIfcIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS obsolete DESCRIPTION "Number of the interface (first table index)." ::= { telProdNpMonInterfFRActCallsEntry 1 } telProdNpMonInterfFRActCallsOrdenIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS obsolete DESCRIPTION "Call order or position in the table (second index)." ::= { telProdNpMonInterfFRActCallsEntry 2 } telProdNpMonInterfFRActCallsCircuitName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS obsolete DESCRIPTION "Circuit name." ::= { telProdNpMonInterfFRActCallsEntry 3 } telProdNpMonInterfFRActCallsDlci OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS obsolete DESCRIPTION "Dlci Number of the circuit through which the call is established." ::= { telProdNpMonInterfFRActCallsEntry 4 } telProdNpMonInterfFRActCallsCalledNum OBJECT-TYPE SYNTAX DisplayString(SIZE(0..15)) ACCESS read-only STATUS obsolete DESCRIPTION "Called number" ::= { telProdNpMonInterfFRActCallsEntry 5 } telProdNpMonInterfFRActCallsCallingNum OBJECT-TYPE SYNTAX DisplayString(SIZE(0..15)) ACCESS read-only STATUS obsolete DESCRIPTION "Calling number." ::= { telProdNpMonInterfFRActCallsEntry 6 } telProdNpMonInterfFRActCallsRef OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS obsolete DESCRIPTION "Call reference." ::= { telProdNpMonInterfFRActCallsEntry 7 } telProdNpMonInterfFRActCallsStartHour OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS obsolete DESCRIPTION "Indicates the hour the call was initialized." ::= { telProdNpMonInterfFRActCallsEntry 8 } telProdNpMonInterfFRActCallsStartMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS obsolete DESCRIPTION "Indicates the minute the call was initialized." ::= { telProdNpMonInterfFRActCallsEntry 9 } telProdNpMonInterfFRActCallsStartSec OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS obsolete DESCRIPTION "Indicates the second the call was initialized." ::= { telProdNpMonInterfFRActCallsEntry 10 } -- Tabla de las llamadas liberadas. La tabla se recorre con ayuda de -- dos ndices: el numero del interfaz y la posicin u orden de la llamada en -- la tabla. Contiene informacin acerca del nombre y numero de dlci del -- circuito sobre el que se ha establecido la llamada, los numeros llamado y -- llamante, la causa de la liberacin y el diagnstico de liberacin, la hora, -- minuto y segundo en que dio comienzo la llamada y la hora minuto y segundo -- en que finaliz. Esta informacin no estar disponible si el interfaz no es -- Frame Relay o Frame Relay sobre RDSI. telProdNpMonInterfFRRelCallsTable OBJECT-TYPE SYNTAX SEQUENCE OF TelProdNpMonInterfFRRelCallsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of released calls. Contains information about the name and dlci of the circuit through which the call was initialized, called and calling numbers, cause and diagnosis of the release, the hour, minute and second the call finished." ::= { telProdNpMonInterfFR 11 } telProdNpMonInterfFRRelCallsEntry OBJECT-TYPE SYNTAX TelProdNpMonInterfFRRelCallsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry contains the number of the node interface (first index), the order number of the call in the table (second index), name and dlci of the circuit through which the call is established, called and calling number, cause and diagnosis of the release, the hour, minute and second the call finished." INDEX { telProdNpMonInterfFRRelCallsIndex, telProdNpMonInterfFRRelCallsOrdenIndex } ::= { telProdNpMonInterfFRRelCallsTable 1 } TelProdNpMonInterfFRRelCallsEntry ::= SEQUENCE { telProdNpMonInterfFRRelCallsIndex INTEGER, telProdNpMonInterfFRRelCallsOrdenIndex INTEGER, telProdNpMonInterfFRRelCallsClear INTEGER, telProdNpMonInterfFRRelCallsCircName DisplayString, telProdNpMonInterfFRRelCallsDlci INTEGER, telProdNpMonInterfFRRelCallsCalledNum DisplayString, telProdNpMonInterfFRRelCallsCallingNum DisplayString, telProdNpMonInterfFRRelCallsCL INTEGER, telProdNpMonInterfFRRelCallsDL INTEGER, telProdNpMonInterfFRRelCallsStartHour INTEGER, telProdNpMonInterfFRRelCallsStartMin INTEGER, telProdNpMonInterfFRRelCallsStartSec INTEGER, telProdNpMonInterfFRRelCallsEndHour INTEGER, telProdNpMonInterfFRRelCallsEndMin INTEGER, telProdNpMonInterfFRRelCallsEndSec INTEGER } telProdNpMonInterfFRRelCallsIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS obsolete DESCRIPTION "Number of interface (first table index)." ::= { telProdNpMonInterfFRRelCallsEntry 1 } telProdNpMonInterfFRRelCallsOrdenIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS obsolete DESCRIPTION "Call order or position in the table (second index)." ::= { telProdNpMonInterfFRRelCallsEntry 2 } telProdNpMonInterfFRRelCallsClear OBJECT-TYPE SYNTAX INTEGER{ delete(1), ok(2), error(3), undefined(4) } ACCESS read-write STATUS obsolete DESCRIPTION "This variable when is read shows the output from the last table delete attempt: the value is 2 if the deletion was performed succesfully, 3 if an error ocurred and 4 for an undefined result, that means that nobody has tried to delete the buffer of released calls yet. When we perform a set operation with value 1, the buffer of released calls is deleted." ::= { telProdNpMonInterfFRRelCallsEntry 3 } telProdNpMonInterfFRRelCallsCircName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS obsolete DESCRIPTION "Name of the circuit through which the call was established." ::= { telProdNpMonInterfFRRelCallsEntry 4 } telProdNpMonInterfFRRelCallsDlci OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS obsolete DESCRIPTION "Dlci number of the circuit through which the call was established." ::= { telProdNpMonInterfFRRelCallsEntry 5 } telProdNpMonInterfFRRelCallsCalledNum OBJECT-TYPE SYNTAX DisplayString(SIZE(0..15)) ACCESS read-only STATUS obsolete DESCRIPTION "Called number." ::= { telProdNpMonInterfFRRelCallsEntry 6 } telProdNpMonInterfFRRelCallsCallingNum OBJECT-TYPE SYNTAX DisplayString(SIZE(0..15)) ACCESS read-only STATUS obsolete DESCRIPTION "Calling number." ::= { telProdNpMonInterfFRRelCallsEntry 7 } telProdNpMonInterfFRRelCallsCL OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS obsolete DESCRIPTION "This indicates why the call has been released." ::= { telProdNpMonInterfFRRelCallsEntry 8 } telProdNpMonInterfFRRelCallsDL OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS obsolete DESCRIPTION "Indicates the released call diagnosis." ::= { telProdNpMonInterfFRRelCallsEntry 9 } telProdNpMonInterfFRRelCallsStartHour OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS obsolete DESCRIPTION "Indicates the hour the call was initialized." ::= { telProdNpMonInterfFRRelCallsEntry 10 } telProdNpMonInterfFRRelCallsStartMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS obsolete DESCRIPTION "Indicates the minute the call was initialized." ::= { telProdNpMonInterfFRRelCallsEntry 11 } telProdNpMonInterfFRRelCallsStartSec OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS obsolete DESCRIPTION "Indicates the second the call was initialized." ::= { telProdNpMonInterfFRRelCallsEntry 12 } telProdNpMonInterfFRRelCallsEndHour OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS obsolete DESCRIPTION "Indicates the hour the call was released." ::= { telProdNpMonInterfFRRelCallsEntry 13 } telProdNpMonInterfFRRelCallsEndMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS obsolete DESCRIPTION "Indicates the minute the call was released." ::= { telProdNpMonInterfFRRelCallsEntry 14 } telProdNpMonInterfFRRelCallsEndSec OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS obsolete DESCRIPTION "Indicates the second the call was released." ::= { telProdNpMonInterfFRRelCallsEntry 15 } END