-- Teldat, S.A. -- Parque Tecnolgico de Madrid -- 28760, Tres Cantos (Madrid) -- Tlf: +34-918076565 -- Fax: +34-918076521 -- e-mail: id@teldat.com -- MIB privada de Teldat -- Monitorizacin de la facilidad BRS (Band Reservation System) -- Historial: -- 07/02/14 M.A. Pastor XH 3523. Errors with HP Openview 9.20 -- 1.7 11-01-13 E. Amorena XH 2610. MIBs compilation. -- 1.6 08/07/09 I. Muoz Revisin de todas las MIB para evitar -- M.A. Pastor warnings y errores de compilacin -- 1.5 19-06-09 I. Muoz PMP 890. Implementacion del comando "traffic-shape-group" -- para las colas -- 1.4 02-03-09 P. Ortiz Nuevas tablas para level-indicator -- 1.3 18-02-09 I. Muoz WRED -- 1.2 01-09-04 M.A. Pastor Nuevos estadsicos -- 1.1 25/06/04 M.A. Pastor Actualizacin de la MIB para que se -- corresponda con la informacin de -- monitorizacin disponible -- 1.0 01/07/04 J. Molina Archivo procedente de BRS.mib -- Historial de BRS.mib: -- 02/10/01 N.Villaseor Traduccin a ingles -- 01/12/00 M.A. Pastor Modificaciones para que pueda ser compilada -- utilizando compiladores distintos del de Teldat -- 7/11/00 J. Alvarez Implementacion inicial -------------------------------------------------------------------------------- TELDAT-MON-FEATURES-BRS-MIB DEFINITIONS ::= BEGIN IMPORTS Counter, Gauge FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 DisplayString FROM RFC1213-MIB telProdNpMonFeatures FROM TELDAT-SW-STRUCTURE-MIB; -- Facilidad de Reserva de Ancho de Banda (BRS) telProdNpMonFeatBrs OBJECT IDENTIFIER ::= { telProdNpMonFeatures 1 } -- Tabla que recoge los estadsicos que describen el trfico de Reserva de -- Ancho de Banda para el interfaz seleccionado. telProdNpMonFeatBrsDevCountTable OBJECT-TYPE SYNTAX SEQUENCE OF TelProdNpMonFeatBrsDevCountEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Displays the last statistics describing bandwidth reservation traffic for the selected interface. For the Frame Relay interface displays the last statistics describing bandwidth reservation traffic for all circuit classes of the interface." ::= { telProdNpMonFeatBrs 1 } telProdNpMonFeatBrsDevCountEntry OBJECT-TYPE SYNTAX TelProdNpMonFeatBrsDevCountEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The table index are: the interface number and the order of the selected class within the interface." INDEX { telProdNpMonFeatBrsDevCountIfc, telProdNpMonFeatBrsDevCountIndex } ::= { telProdNpMonFeatBrsDevCountTable 1 } TelProdNpMonFeatBrsDevCountEntry ::= SEQUENCE{ telProdNpMonFeatBrsDevCountIfc INTEGER, telProdNpMonFeatBrsDevCountIndex INTEGER, telProdNpMonFeatBrsDevCountClear INTEGER, telProdNpMonFeatBrsDevCountClass DisplayString, telProdNpMonFeatBrsDevCountTxPkt Counter, telProdNpMonFeatBrsDevCountTxByt Counter, telProdNpMonFeatBrsDevCountDiscByt Counter, telProdNpMonFeatBrsDevCountDiscPkt Counter, telProdNpMonFeatBrsDevCountInPkt Counter, telProdNpMonFeatBrsDevCountInByt Counter, telProdNpMonFeatBrsDevCountDiscRLPkt Counter, telProdNpMonFeatBrsDevCountDiscRLByt Counter, telProdNpMonFeatBrsDevCountRemarkPkt Counter, telProdNpMonFeatBrsDevCountRemarkByt Counter, telProdNpMonFeatBrsDevCountReassPkt Counter, telProdNpMonFeatBrsDevCountReassByt Counter, telProdNpMonFeatBrsDevCountLoopPkt Counter, telProdNpMonFeatBrsDevCountLoopByt Counter, telProdNpMonFeatBrsDevCountQueueOvflPkt Counter, telProdNpMonFeatBrsDevCountQueueOvflByt Counter, telProdNpMonFeatBrsDevCountWredPkt Counter, telProdNpMonFeatBrsDevCountWredByt Counter } telProdNpMonFeatBrsDevCountIfc OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "First index: interface number." ::= { telProdNpMonFeatBrsDevCountEntry 1 } telProdNpMonFeatBrsDevCountIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Second index: class order within the interface." ::= { telProdNpMonFeatBrsDevCountEntry 2 } telProdNpMonFeatBrsDevCountClear OBJECT-TYPE SYNTAX INTEGER{ delete(1), ok(2), error(3), undefined(4) } ACCESS read-write STATUS mandatory DESCRIPTION "Clear command to delete statistics. Enter 1 (delete) to clear the counters. In case the counters were correctly deleted, it will appear 2 (ok); otherwise it will appear 3 (error). Finally, if the counter has been never cleared it will appear 4 (undefined)." ::= { telProdNpMonFeatBrsDevCountEntry 3 } telProdNpMonFeatBrsDevCountClass OBJECT-TYPE SYNTAX DisplayString(SIZE(0..9)) ACCESS read-only STATUS mandatory DESCRIPTION "Class name." ::= { telProdNpMonFeatBrsDevCountEntry 4 } telProdNpMonFeatBrsDevCountTxPkt OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of packets transmitted." ::= { telProdNpMonFeatBrsDevCountEntry 5 } telProdNpMonFeatBrsDevCountTxByt OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of bytes transmitted." ::= { telProdNpMonFeatBrsDevCountEntry 6 } telProdNpMonFeatBrsDevCountDiscByt OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of bytes lost due to overflow." ::= { telProdNpMonFeatBrsDevCountEntry 7 } telProdNpMonFeatBrsDevCountDiscPkt OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of discarded packets." ::= { telProdNpMonFeatBrsDevCountEntry 8 } telProdNpMonFeatBrsDevCountInPkt OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of input packets: packets offered to a class before the application of any QoS action." ::= { telProdNpMonFeatBrsDevCountEntry 9 } telProdNpMonFeatBrsDevCountInByt OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of input bytes: bytes offered to a class before the application of any QoS action." ::= { telProdNpMonFeatBrsDevCountEntry 10 } telProdNpMonFeatBrsDevCountDiscRLPkt OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of discarded packets due to rate-limit." ::= { telProdNpMonFeatBrsDevCountEntry 11 } telProdNpMonFeatBrsDevCountDiscRLByt OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of discarded bytes due to rate-limit." ::= { telProdNpMonFeatBrsDevCountEntry 12 } telProdNpMonFeatBrsDevCountRemarkPkt OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of exceeded packets which are dscp-marked." ::= { telProdNpMonFeatBrsDevCountEntry 13 } telProdNpMonFeatBrsDevCountRemarkByt OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of exceeded bytes which are dscp-marked." ::= { telProdNpMonFeatBrsDevCountEntry 14 } telProdNpMonFeatBrsDevCountReassPkt OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of exceeded packets which are re-classified (reassigned to another BRS class)." ::= { telProdNpMonFeatBrsDevCountEntry 15 } telProdNpMonFeatBrsDevCountReassByt OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of exceeded bytes which are re-classified (reassigned to another BRS class)." ::= { telProdNpMonFeatBrsDevCountEntry 16 } telProdNpMonFeatBrsDevCountLoopPkt OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of discarded packets because they were re-classified and reassigned to a class to which they were previously assigned." ::= { telProdNpMonFeatBrsDevCountEntry 17 } telProdNpMonFeatBrsDevCountLoopByt OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of discarded bytes because they were re-classified and reassigned to a class to which they were previously assigned." ::= { telProdNpMonFeatBrsDevCountEntry 18 } telProdNpMonFeatBrsDevCountQueueOvflPkt OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of discarded packets due to queue overflow." ::= { telProdNpMonFeatBrsDevCountEntry 19 } telProdNpMonFeatBrsDevCountQueueOvflByt OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of discarded bytes due to queue overflow." ::= { telProdNpMonFeatBrsDevCountEntry 20 } telProdNpMonFeatBrsDevCountWredPkt OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of discarded packets due to WRED." ::= { telProdNpMonFeatBrsDevCountEntry 21 } telProdNpMonFeatBrsDevCountWredByt OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of discarded bytes due to WRED." ::= { telProdNpMonFeatBrsDevCountEntry 22 } -- Tabla que muestra las "ltimas estadsticas de Reserva de Ancho de Banda -- salvadas de los interfaces. telProdNpMonFeatBrsDevLastTable OBJECT-TYPE SYNTAX SEQUENCE OF TelProdNpMonFeatBrsDevLastEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Displays the last statistics of bandwidth reservation saved for the interfaces." ::= { telProdNpMonFeatBrs 2 } telProdNpMonFeatBrsDevLastEntry OBJECT-TYPE SYNTAX TelProdNpMonFeatBrsDevLastEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The table index are: the interface number and the order of the selected class within the interface." INDEX { telProdNpMonFeatBrsDevLastIfc, telProdNpMonFeatBrsDevLastIndex } ::= { telProdNpMonFeatBrsDevLastTable 1 } TelProdNpMonFeatBrsDevLastEntry ::= SEQUENCE{ telProdNpMonFeatBrsDevLastIfc INTEGER, telProdNpMonFeatBrsDevLastIndex INTEGER, telProdNpMonFeatBrsDevLastClass DisplayString, telProdNpMonFeatBrsDevLastTxPkt Counter, telProdNpMonFeatBrsDevLastTxByt Counter, telProdNpMonFeatBrsDevLastDiscByt Counter, telProdNpMonFeatBrsDevLastDiscPkt Counter, telProdNpMonFeatBrsDevLastInPkt Counter, telProdNpMonFeatBrsDevLastInByt Counter, telProdNpMonFeatBrsDevLastDiscRLPkt Counter, telProdNpMonFeatBrsDevLastDiscRLByt Counter, telProdNpMonFeatBrsDevLastRemarkPkt Counter, telProdNpMonFeatBrsDevLastRemarkByt Counter, telProdNpMonFeatBrsDevLastReassPkt Counter, telProdNpMonFeatBrsDevLastReassByt Counter, telProdNpMonFeatBrsDevLastLoopPkt Counter, telProdNpMonFeatBrsDevLastLoopByt Counter, telProdNpMonFeatBrsDevLastQueueOvflPkt Counter, telProdNpMonFeatBrsDevLastQueueOvflByt Counter, telProdNpMonFeatBrsDevLastWredPkt Counter, telProdNpMonFeatBrsDevLastWredByt Counter } telProdNpMonFeatBrsDevLastIfc OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "First index: interface number." ::= { telProdNpMonFeatBrsDevLastEntry 1 } telProdNpMonFeatBrsDevLastIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Second index: class order within the interface." ::= { telProdNpMonFeatBrsDevLastEntry 2 } telProdNpMonFeatBrsDevLastClass OBJECT-TYPE SYNTAX DisplayString(SIZE(0..9)) ACCESS read-only STATUS mandatory DESCRIPTION "Class name." ::= { telProdNpMonFeatBrsDevLastEntry 3 } telProdNpMonFeatBrsDevLastTxPkt OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of packets transmitted." ::= { telProdNpMonFeatBrsDevLastEntry 4 } telProdNpMonFeatBrsDevLastTxByt OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of bytes transmitted." ::= { telProdNpMonFeatBrsDevLastEntry 5 } telProdNpMonFeatBrsDevLastDiscByt OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of bytes lost due to overflow." ::= { telProdNpMonFeatBrsDevLastEntry 6 } telProdNpMonFeatBrsDevLastDiscPkt OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of discarded packets." ::= { telProdNpMonFeatBrsDevLastEntry 7 } telProdNpMonFeatBrsDevLastInPkt OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of input packets: packets offered to a class before the application of any QoS action." ::= { telProdNpMonFeatBrsDevLastEntry 8 } telProdNpMonFeatBrsDevLastInByt OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of input bytes: bytes offered to a class before the application of any QoS action." ::= { telProdNpMonFeatBrsDevLastEntry 9 } telProdNpMonFeatBrsDevLastDiscRLPkt OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of discarded packets due to rate-limit." ::= { telProdNpMonFeatBrsDevLastEntry 10 } telProdNpMonFeatBrsDevLastDiscRLByt OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of discarded bytes due to rate-limit." ::= { telProdNpMonFeatBrsDevLastEntry 11 } telProdNpMonFeatBrsDevLastRemarkPkt OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of exceeded packets which are dscp-marked." ::= { telProdNpMonFeatBrsDevLastEntry 12 } telProdNpMonFeatBrsDevLastRemarkByt OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of exceeded bytes which are dscp-marked." ::= { telProdNpMonFeatBrsDevLastEntry 13 } telProdNpMonFeatBrsDevLastReassPkt OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of exceeded packets which are re-classified (reassigned to another BRS class)." ::= { telProdNpMonFeatBrsDevLastEntry 14 } telProdNpMonFeatBrsDevLastReassByt OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of exceeded bytes which are re-classified (reassigned to another BRS class)." ::= { telProdNpMonFeatBrsDevLastEntry 15 } telProdNpMonFeatBrsDevLastLoopPkt OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of discarded packets because they were re-classified and reassigned to a class to which they were previously assigned." ::= { telProdNpMonFeatBrsDevLastEntry 16 } telProdNpMonFeatBrsDevLastLoopByt OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of discarded bytes because they were re-classified and reassigned to a class to which they were previously assigned." ::= { telProdNpMonFeatBrsDevLastEntry 17 } telProdNpMonFeatBrsDevLastQueueOvflPkt OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of discarded packets due to queue overflow." ::= { telProdNpMonFeatBrsDevLastEntry 18 } telProdNpMonFeatBrsDevLastQueueOvflByt OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of discarded bytes due to queue overflow." ::= { telProdNpMonFeatBrsDevLastEntry 19 } telProdNpMonFeatBrsDevLastWredPkt OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of discarded packets due to WRED." ::= { telProdNpMonFeatBrsDevLastEntry 20 } telProdNpMonFeatBrsDevLastWredByt OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of discarded bytes due to WRED." ::= { telProdNpMonFeatBrsDevLastEntry 21 } -- Tabla que muestra los estadsicos que describen el trfico de Reserva de -- Ancho de Banda para el interfaz FR y circuito. telProdNpMonFeatBrsFrCirCountTable OBJECT-TYPE SYNTAX SEQUENCE OF TelProdNpMonFeatBrsFrCirCountEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Displays statistics describing bandwidth reservation traffic for the selected Frame Relay interface and circuit." ::= { telProdNpMonFeatBrs 3 } telProdNpMonFeatBrsFrCirCountEntry OBJECT-TYPE SYNTAX TelProdNpMonFeatBrsFrCirCountEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry contains statistics describing bandwidth reservation traffic for the selected Frame Relay interface and circuit. The table index are: the interface number, the Frame Relay circuit number (DLCI) and the class order within that circuit in this Frame Relay interface." INDEX { telProdNpMonFeatBrsFrCirCountIfc, telProdNpMonFeatBrsFrCirCountCir, telProdNpMonFeatBrsFrCirCountIndex } ::= { telProdNpMonFeatBrsFrCirCountTable 1 } TelProdNpMonFeatBrsFrCirCountEntry ::= SEQUENCE{ telProdNpMonFeatBrsFrCirCountIfc INTEGER, telProdNpMonFeatBrsFrCirCountCir INTEGER, telProdNpMonFeatBrsFrCirCountIndex INTEGER, telProdNpMonFeatBrsFrCirCountClear INTEGER, telProdNpMonFeatBrsFrCirCountClass DisplayString, telProdNpMonFeatBrsFrCirCountTxPkt Counter, telProdNpMonFeatBrsFrCirCountTxByt Counter, telProdNpMonFeatBrsFrCirCountDiscByt Counter, telProdNpMonFeatBrsFrCirCountDiscPkt Counter, telProdNpMonFeatBrsFrCirCountInPkt Counter, telProdNpMonFeatBrsFrCirCountInByt Counter, telProdNpMonFeatBrsFrCirCountDiscRLPkt Counter, telProdNpMonFeatBrsFrCirCountDiscRLByt Counter, telProdNpMonFeatBrsFrCirCountRemarkPkt Counter, telProdNpMonFeatBrsFrCirCountRemarkByt Counter, telProdNpMonFeatBrsFrCirCountReassPkt Counter, telProdNpMonFeatBrsFrCirCountReassByt Counter, telProdNpMonFeatBrsFrCirCountLoopPkt Counter, telProdNpMonFeatBrsFrCirCountLoopByt Counter, telProdNpMonFeatBrsFrCirCountQueueOvflPkt Counter, telProdNpMonFeatBrsFrCirCountQueueOvflByt Counter, telProdNpMonFeatBrsFrCirCountWredPkt Counter, telProdNpMonFeatBrsFrCirCountWredByt Counter } telProdNpMonFeatBrsFrCirCountIfc OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "First index: interface number." ::= { telProdNpMonFeatBrsFrCirCountEntry 1 } telProdNpMonFeatBrsFrCirCountCir OBJECT-TYPE SYNTAX INTEGER(16..1007) ACCESS read-only STATUS mandatory DESCRIPTION "Second index: Frame Relay circuit number (DLCI)." ::= { telProdNpMonFeatBrsFrCirCountEntry 2 } telProdNpMonFeatBrsFrCirCountIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Third index: class order within that circuit in this Frame Relay interface." ::= { telProdNpMonFeatBrsFrCirCountEntry 3 } telProdNpMonFeatBrsFrCirCountClear OBJECT-TYPE SYNTAX INTEGER{ delete(1), ok(2), error(3), undefined(4) } ACCESS read-write STATUS mandatory DESCRIPTION "Clear command to delete statistics. Enter 1 (delete) to clear the counters. In case the counters were correctly deleted, it will appear 2 (ok); otherwise it will appear 3 (error). Finally, if the counter has been never cleared it will appear 4 (undefined)." ::= { telProdNpMonFeatBrsFrCirCountEntry 4 } telProdNpMonFeatBrsFrCirCountClass OBJECT-TYPE SYNTAX DisplayString(SIZE(0..9)) ACCESS read-only STATUS mandatory DESCRIPTION "Class name." ::= { telProdNpMonFeatBrsFrCirCountEntry 5 } telProdNpMonFeatBrsFrCirCountTxPkt OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of packets transmitted." ::= { telProdNpMonFeatBrsFrCirCountEntry 6 } telProdNpMonFeatBrsFrCirCountTxByt OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of bytes transmitted." ::= { telProdNpMonFeatBrsFrCirCountEntry 7 } telProdNpMonFeatBrsFrCirCountDiscByt OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of packets lost due to overflow." ::= { telProdNpMonFeatBrsFrCirCountEntry 8 } telProdNpMonFeatBrsFrCirCountDiscPkt OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of discarded packets." ::= { telProdNpMonFeatBrsFrCirCountEntry 9 } telProdNpMonFeatBrsFrCirCountInPkt OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of input packets: packets offered to a class before the application of any QoS action." ::= { telProdNpMonFeatBrsFrCirCountEntry 10 } telProdNpMonFeatBrsFrCirCountInByt OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of input bytes: bytes offered to a class before the application of any QoS action." ::= { telProdNpMonFeatBrsFrCirCountEntry 11 } telProdNpMonFeatBrsFrCirCountDiscRLPkt OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of discarded packets due to rate-limit." ::= { telProdNpMonFeatBrsFrCirCountEntry 12 } telProdNpMonFeatBrsFrCirCountDiscRLByt OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of discarded bytes due to rate-limit." ::= { telProdNpMonFeatBrsFrCirCountEntry 13 } telProdNpMonFeatBrsFrCirCountRemarkPkt OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of exceeded packets which are dscp-marked." ::= { telProdNpMonFeatBrsFrCirCountEntry 14 } telProdNpMonFeatBrsFrCirCountRemarkByt OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of exceeded bytes which are dscp-marked." ::= { telProdNpMonFeatBrsFrCirCountEntry 15 } telProdNpMonFeatBrsFrCirCountReassPkt OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of exceeded packets which are re-classified (reassigned to another BRS class)." ::= { telProdNpMonFeatBrsFrCirCountEntry 16 } telProdNpMonFeatBrsFrCirCountReassByt OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of exceeded bytes which are re-classified (reassigned to another BRS class)." ::= { telProdNpMonFeatBrsFrCirCountEntry 17 } telProdNpMonFeatBrsFrCirCountLoopPkt OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of discarded packets because they were re-classified and reassigned to a class to which they were previously assigned." ::= { telProdNpMonFeatBrsFrCirCountEntry 18 } telProdNpMonFeatBrsFrCirCountLoopByt OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of discarded bytes because they were re-classified and reassigned to a class to which they were previously assigned." ::= { telProdNpMonFeatBrsFrCirCountEntry 19 } telProdNpMonFeatBrsFrCirCountQueueOvflPkt OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS obsolete DESCRIPTION "Number of discarded packets due to queue overflow." ::= { telProdNpMonFeatBrsFrCirCountEntry 20 } telProdNpMonFeatBrsFrCirCountQueueOvflByt OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS obsolete DESCRIPTION "Number of discarded bytes due to queue overflow." ::= { telProdNpMonFeatBrsFrCirCountEntry 21 } telProdNpMonFeatBrsFrCirCountWredPkt OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of discarded packets due to WRED." ::= { telProdNpMonFeatBrsFrCirCountEntry 22 } telProdNpMonFeatBrsFrCirCountWredByt OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of discarded bytes due to WRED." ::= { telProdNpMonFeatBrsFrCirCountEntry 23 } -- Tabla que muestra los "ltimos estadsicos salvados de Reserva de Ancho de -- Banda para el interfaz FR y circuito seleccionado. telProdNpMonFeatBrsFrCirLastTable OBJECT-TYPE SYNTAX SEQUENCE OF TelProdNpMonFeatBrsFrCirLastEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Displays last statistics of bandwidth reservation saved for the selected Frame Relay interface and circuit." ::= { telProdNpMonFeatBrs 4 } telProdNpMonFeatBrsFrCirLastEntry OBJECT-TYPE SYNTAX TelProdNpMonFeatBrsFrCirLastEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The table index are: the interface number, the Frame Relay circuit number (DLCI) and the class order within that circuit in this Frame Relay interface." INDEX { telProdNpMonFeatBrsFrCirLastIfc, telProdNpMonFeatBrsFrCirLastCir, telProdNpMonFeatBrsFrCirLastIndex } ::= { telProdNpMonFeatBrsFrCirLastTable 1 } TelProdNpMonFeatBrsFrCirLastEntry ::= SEQUENCE{ telProdNpMonFeatBrsFrCirLastIfc INTEGER, telProdNpMonFeatBrsFrCirLastCir INTEGER, telProdNpMonFeatBrsFrCirLastIndex INTEGER, telProdNpMonFeatBrsFrCirLastClass DisplayString, telProdNpMonFeatBrsFrCirLastTxPkt Counter, telProdNpMonFeatBrsFrCirLastTxByt Counter, telProdNpMonFeatBrsFrCirLastDiscByt Counter, telProdNpMonFeatBrsFrCirLastDiscByt Counter, telProdNpMonFeatBrsFrCirLastDiscPkt Counter, telProdNpMonFeatBrsFrCirLastInPkt Counter, telProdNpMonFeatBrsFrCirLastInByt Counter, telProdNpMonFeatBrsFrCirLastDiscRLPkt Counter, telProdNpMonFeatBrsFrCirLastDiscRLByt Counter, telProdNpMonFeatBrsFrCirLastRemarkPkt Counter, telProdNpMonFeatBrsFrCirLastRemarkByt Counter, telProdNpMonFeatBrsFrCirLastReassPkt Counter, telProdNpMonFeatBrsFrCirLastReassByt Counter, telProdNpMonFeatBrsFrCirLastLoopPkt Counter, telProdNpMonFeatBrsFrCirLastLoopByt Counter, telProdNpMonFeatBrsFrCirLastQueueOvflPkt Counter, telProdNpMonFeatBrsFrCirLastQueueOvflByt Counter, telProdNpMonFeatBrsFrCirLastWredPkt Counter, telProdNpMonFeatBrsFrCirLastWredByt Counter } telProdNpMonFeatBrsFrCirLastIfc OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "First index: interface number." ::= { telProdNpMonFeatBrsFrCirLastEntry 1 } telProdNpMonFeatBrsFrCirLastCir OBJECT-TYPE SYNTAX INTEGER(16..1007) ACCESS read-only STATUS mandatory DESCRIPTION "Second index: Frame Relay circuit number (DLCI)." ::= { telProdNpMonFeatBrsFrCirLastEntry 2 } telProdNpMonFeatBrsFrCirLastIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Third index: class order within that circuit in this Frame Relay interface." ::= { telProdNpMonFeatBrsFrCirLastEntry 3 } telProdNpMonFeatBrsFrCirLastClass OBJECT-TYPE SYNTAX DisplayString(SIZE(0..9)) ACCESS read-only STATUS mandatory DESCRIPTION "Class name." ::= { telProdNpMonFeatBrsFrCirLastEntry 4 } telProdNpMonFeatBrsFrCirLastTxPkt OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of packets transmitted." ::= { telProdNpMonFeatBrsFrCirLastEntry 5 } telProdNpMonFeatBrsFrCirLastTxByt OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of bytes transmitted." ::= { telProdNpMonFeatBrsFrCirLastEntry 6 } telProdNpMonFeatBrsFrCirLastDiscByt OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of bytes lost due to overflow." ::= { telProdNpMonFeatBrsFrCirLastEntry 7 } telProdNpMonFeatBrsFrCirLastDiscPkt OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of discarded packets." ::= { telProdNpMonFeatBrsFrCirLastEntry 8 } telProdNpMonFeatBrsFrCirLastInPkt OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of input packets: packets offered to a class before the application of any QoS action." ::= { telProdNpMonFeatBrsFrCirLastEntry 9 } telProdNpMonFeatBrsFrCirLastInByt OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of input bytes: bytes offered to a class before the application of any QoS action." ::= { telProdNpMonFeatBrsFrCirLastEntry 10 } telProdNpMonFeatBrsFrCirLastDiscRLPkt OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of discarded packets due to rate-limit." ::= { telProdNpMonFeatBrsFrCirLastEntry 11 } telProdNpMonFeatBrsFrCirLastDiscRLByt OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of discarded bytes due to rate-limit." ::= { telProdNpMonFeatBrsFrCirLastEntry 12 } telProdNpMonFeatBrsFrCirLastRemarkPkt OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of exceeded packets which are dscp-marked." ::= { telProdNpMonFeatBrsFrCirLastEntry 13 } telProdNpMonFeatBrsFrCirLastRemarkByt OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of exceeded bytes which are dscp-marked." ::= { telProdNpMonFeatBrsFrCirLastEntry 14 } telProdNpMonFeatBrsFrCirLastReassPkt OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of exceeded packets which are re-classified (reassigned to another BRS class)." ::= { telProdNpMonFeatBrsFrCirLastEntry 15 } telProdNpMonFeatBrsFrCirLastReassByt OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of exceeded bytes which are re-classified (reassigned to another BRS class)." ::= { telProdNpMonFeatBrsFrCirLastEntry 16 } telProdNpMonFeatBrsFrCirLastLoopPkt OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of discarded packets because they were re-classified and reassigned to a class to which they were previously assigned." ::= { telProdNpMonFeatBrsFrCirLastEntry 17 } telProdNpMonFeatBrsFrCirLastLoopByt OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of discarded bytes because they were re-classified and reassigned to a class to which they were previously assigned." ::= { telProdNpMonFeatBrsFrCirLastEntry 18 } telProdNpMonFeatBrsFrCirLastQueueOvflPkt OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS obsolete DESCRIPTION "Number of discarded packets due to queue overflow." ::= { telProdNpMonFeatBrsFrCirLastEntry 19 } telProdNpMonFeatBrsFrCirLastQueueOvflByt OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS obsolete DESCRIPTION "Number of discarded bytes due to queue overflow." ::= { telProdNpMonFeatBrsFrCirLastEntry 20 } telProdNpMonFeatBrsFrCirLastWredPkt OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of discarded packets due to WRED." ::= { telProdNpMonFeatBrsFrCirLastEntry 21 } telProdNpMonFeatBrsFrCirLastWredByt OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of discarded bytes due to WRED." ::= { telProdNpMonFeatBrsFrCirLastEntry 22 } -- Tabla que contiene los datos de las longitudes de las colas asociadas a cada -- clase y prioridad, as como su ocupacin, y esto para cada interfaz -- configurado en el equipo con Reserva de Ancho de Banda. telProdNpMonFeatBrsDevQueueTable OBJECT-TYPE SYNTAX SEQUENCE OF TelProdNpMonFeatBrsDevQueueEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains information about the length and occupation of the BRS queues for each class and each priority in all interfaces with this facility enabled." ::= { telProdNpMonFeatBrs 5 } telProdNpMonFeatBrsDevQueueEntry OBJECT-TYPE SYNTAX TelProdNpMonFeatBrsDevQueueEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry in the table contains data about the length and occupation of the BRS queues for a class within an interface. The entry is comprised of several variables to store the current value and the maximum permitted value of the queues for each priority within a configured class in an interface. In cases of PPP interfaces with real-time traffic, the occupation of non-real-time traffic also appears." INDEX { telProdNpMonFeatBrsDevQueueIfc, telProdNpMonFeatBrsDevQueueClassNum } ::= { telProdNpMonFeatBrsDevQueueTable 1 } TelProdNpMonFeatBrsDevQueueEntry ::= SEQUENCE{ telProdNpMonFeatBrsDevQueueIfc INTEGER, telProdNpMonFeatBrsDevQueueClassNum INTEGER, telProdNpMonFeatBrsDevQueueClassName DisplayString, telProdNpMonFeatBrsDevQueueUrgNum Gauge, telProdNpMonFeatBrsDevQueueUrgLen INTEGER, telProdNpMonFeatBrsDevQueueHighNum Gauge, telProdNpMonFeatBrsDevQueueHighLen INTEGER, telProdNpMonFeatBrsDevQueueNormNum Gauge, telProdNpMonFeatBrsDevQueueNormLen INTEGER, telProdNpMonFeatBrsDevQueueLowNum Gauge, telProdNpMonFeatBrsDevQueueLowLen INTEGER, telProdNpMonFeatBrsDevQueueThroughput INTEGER } telProdNpMonFeatBrsDevQueueIfc OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "First index: interface number." ::= { telProdNpMonFeatBrsDevQueueEntry 1 } telProdNpMonFeatBrsDevQueueClassNum OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Second index: class order within the interface." ::= { telProdNpMonFeatBrsDevQueueEntry 2 } telProdNpMonFeatBrsDevQueueClassName OBJECT-TYPE SYNTAX DisplayString(SIZE(0..9)) ACCESS read-only STATUS mandatory DESCRIPTION "Class name." ::= { telProdNpMonFeatBrsDevQueueEntry 3 } telProdNpMonFeatBrsDevQueueUrgNum OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "Current value of the urgent priority queue." ::= { telProdNpMonFeatBrsDevQueueEntry 4 } telProdNpMonFeatBrsDevQueueUrgLen OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Length of the urgent priority queue." ::= { telProdNpMonFeatBrsDevQueueEntry 5 } telProdNpMonFeatBrsDevQueueHighNum OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "Current value of the high priority queue." ::= { telProdNpMonFeatBrsDevQueueEntry 6 } telProdNpMonFeatBrsDevQueueHighLen OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Length of the high priority queue." ::= { telProdNpMonFeatBrsDevQueueEntry 7 } telProdNpMonFeatBrsDevQueueNormNum OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "Current value of the normal priority queue." ::= { telProdNpMonFeatBrsDevQueueEntry 8 } telProdNpMonFeatBrsDevQueueNormLen OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Length of the normal priority queue." ::= { telProdNpMonFeatBrsDevQueueEntry 9 } telProdNpMonFeatBrsDevQueueLowNum OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "Current value of the low priority queue." ::= { telProdNpMonFeatBrsDevQueueEntry 10 } telProdNpMonFeatBrsDevQueueLowLen OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Length of the low priority queue." ::= { telProdNpMonFeatBrsDevQueueEntry 11 } telProdNpMonFeatBrsDevQueueThroughput OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Throughput of class." ::= { telProdNpMonFeatBrsDevQueueEntry 12 } -- Tabla que contiene los datos de las longitudes de las colas asociadas a cada -- clase y prioridad, as como su ocupacin, y esto para cada uno de los DLCIs -- de los interfaces Frame Relay configurados en el equipo con Reserva de Ancho -- de Banda. telProdNpMonFeatBrsFRCirQueueTable OBJECT-TYPE SYNTAX SEQUENCE OF TelProdNpMonFeatBrsFRCirQueueEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains information about the length and occupation of the BRS queues for each class and each priority in all Frame Relay circuits with this facility enabled." ::= { telProdNpMonFeatBrs 6 } telProdNpMonFeatBrsFRCirQueueEntry OBJECT-TYPE SYNTAX TelProdNpMonFeatBrsFRCirQueueEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry in the table contains data about the length and occupation of the BRS queues for a class within a circuit in a Frame Relay interface. The entry is comprised of several variables to store the current value and the maximum permitted value of the queues for each priority within a configured class in an interface." INDEX { telProdNpMonFeatBrsFRCirQueueIfc, telProdNpMonFeatBrsFRCirQueueDlci, telProdNpMonFeatBrsFRCirQueueClassNum } ::= { telProdNpMonFeatBrsFRCirQueueTable 1 } TelProdNpMonFeatBrsFRCirQueueEntry ::= SEQUENCE{ telProdNpMonFeatBrsFRCirQueueIfc INTEGER, telProdNpMonFeatBrsFRCirQueueDlci INTEGER, telProdNpMonFeatBrsFRCirQueueClassNum INTEGER, telProdNpMonFeatBrsFRCirQueueClassName DisplayString, telProdNpMonFeatBrsFRCirQueueUrgNum Gauge, telProdNpMonFeatBrsFRCirQueueUrgLen INTEGER, telProdNpMonFeatBrsFRCirQueueHighNum Gauge, telProdNpMonFeatBrsFRCirQueueHighLen INTEGER, telProdNpMonFeatBrsFRCirQueueNormNum Gauge, telProdNpMonFeatBrsFRCirQueueNormLen INTEGER, telProdNpMonFeatBrsFRCirQueueLowNum Gauge, telProdNpMonFeatBrsFRCirQueueLowLen INTEGER, telProdNpMonFeatBrsFRCirQueueThroughput INTEGER } telProdNpMonFeatBrsFRCirQueueIfc OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "First index: interface number." ::= { telProdNpMonFeatBrsFRCirQueueEntry 1 } telProdNpMonFeatBrsFRCirQueueDlci OBJECT-TYPE SYNTAX INTEGER(16..1007) ACCESS read-only STATUS mandatory DESCRIPTION "Second index: Frame Relay circuit number (DLCI)." ::= { telProdNpMonFeatBrsFRCirQueueEntry 2 } telProdNpMonFeatBrsFRCirQueueClassNum OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Third index: class order within that circuit in this Frame Relay interface." ::= { telProdNpMonFeatBrsFRCirQueueEntry 3 } telProdNpMonFeatBrsFRCirQueueClassName OBJECT-TYPE SYNTAX DisplayString(SIZE(0..9)) ACCESS read-only STATUS mandatory DESCRIPTION "Class name." ::= { telProdNpMonFeatBrsFRCirQueueEntry 4 } telProdNpMonFeatBrsFRCirQueueUrgNum OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "Current value of the urgent priority queue." ::= { telProdNpMonFeatBrsFRCirQueueEntry 5 } telProdNpMonFeatBrsFRCirQueueUrgLen OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Length of the urgent priority queue." ::= { telProdNpMonFeatBrsFRCirQueueEntry 6 } telProdNpMonFeatBrsFRCirQueueHighNum OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "Current value of the high priority queue." ::= { telProdNpMonFeatBrsFRCirQueueEntry 7 } telProdNpMonFeatBrsFRCirQueueHighLen OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Length of the high priority queue." ::= { telProdNpMonFeatBrsFRCirQueueEntry 8 } telProdNpMonFeatBrsFRCirQueueNormNum OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "Current value of the normal priority queue." ::= { telProdNpMonFeatBrsFRCirQueueEntry 9 } telProdNpMonFeatBrsFRCirQueueNormLen OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Length of the normal priority queue." ::= { telProdNpMonFeatBrsFRCirQueueEntry 10 } telProdNpMonFeatBrsFRCirQueueLowNum OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "Current value of the low priority queue." ::= { telProdNpMonFeatBrsFRCirQueueEntry 11 } telProdNpMonFeatBrsFRCirQueueLowLen OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Length of the low priority queue." ::= { telProdNpMonFeatBrsFRCirQueueEntry 12 } telProdNpMonFeatBrsFRCirQueueThroughput OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Throughput of class." ::= { telProdNpMonFeatBrsFRCirQueueEntry 13 } -- Tabla que contiene la informacin relativa a traffic-shaping para cada clase -- dentro de cada interfaz configurado en el equipo con Reserva de Ancho de -- Banda. telProdNpMonFeatBrsDevTSTable OBJECT-TYPE SYNTAX SEQUENCE OF TelProdNpMonFeatBrsDevTSEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains information relative to traffic-shaping for each class and for the whole interface ('Global' row)." ::= { telProdNpMonFeatBrs 7 } telProdNpMonFeatBrsDevTSEntry OBJECT-TYPE SYNTAX TelProdNpMonFeatBrsDevTSEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry is comprised of several variables to store information relative to traffic-shaping for one class within an interface or for the whole interface ('Global' row)." INDEX { telProdNpMonFeatBrsDevTSIfc, telProdNpMonFeatBrsDevTSClassNum } ::= { telProdNpMonFeatBrsDevTSTable 1 } TelProdNpMonFeatBrsDevTSEntry ::= SEQUENCE{ telProdNpMonFeatBrsDevTSIfc INTEGER, telProdNpMonFeatBrsDevTSClassNum INTEGER, telProdNpMonFeatBrsDevTSClear INTEGER, telProdNpMonFeatBrsDevTSClassName DisplayString, telProdNpMonFeatBrsDevTSCir INTEGER, telProdNpMonFeatBrsDevTSBurst INTEGER, telProdNpMonFeatBrsDevTSState INTEGER, telProdNpMonFeatBrsDevTSQueued INTEGER, telProdNpMonFeatBrsDevTSLastTx INTEGER, telProdNpMonFeatBrsDevTSThroughput INTEGER } telProdNpMonFeatBrsDevTSIfc OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "First index: interface number." ::= { telProdNpMonFeatBrsDevTSEntry 1 } telProdNpMonFeatBrsDevTSClassNum OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Second index: class order within the interface." ::= { telProdNpMonFeatBrsDevTSEntry 2 } telProdNpMonFeatBrsDevTSClear OBJECT-TYPE SYNTAX INTEGER{ delete(1), ok(2), error(3), undefined(4) } ACCESS read-write STATUS mandatory DESCRIPTION "This variable is used to make a clear operation: when it is set to 1 (delete), a clear command is executed, starting the measure of the throughput in this moment. The throughput measuring will only take into account those packets which are transmitted after this instant. In reading operations (GET) this variable will show the result of last clear operation attempt: the value is 2 (ok) if clear operation was performed succesfully, 3 (error) if an error ocurred and 4 (undefined) if no clear operations have been made yet." ::= { telProdNpMonFeatBrsDevTSEntry 3 } telProdNpMonFeatBrsDevTSClassName OBJECT-TYPE SYNTAX DisplayString(SIZE(0..9)) ACCESS read-only STATUS mandatory DESCRIPTION "Class name." ::= { telProdNpMonFeatBrsDevTSEntry 4 } telProdNpMonFeatBrsDevTSCir OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Maximum average permitted throughput (0 indicates there is no limit)." ::= { telProdNpMonFeatBrsDevTSEntry 5 } telProdNpMonFeatBrsDevTSBurst OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Currently used burst size (in bits)." ::= { telProdNpMonFeatBrsDevTSEntry 6 } telProdNpMonFeatBrsDevTSState OBJECT-TYPE SYNTAX INTEGER{ congested(1), bursting(2), ready(3) } ACCESS read-only STATUS mandatory DESCRIPTION "There are three possible states: (1) congested, (2) bursting, (3) ready. Transmission cannot be executed when a class or an interface is congested; transmission is possible in any other state." ::= { telProdNpMonFeatBrsDevTSEntry 7 } telProdNpMonFeatBrsDevTSQueued OBJECT-TYPE SYNTAX INTEGER{ yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates if this class is queued: when a class is queued, there is traffic to be transmitted." ::= { telProdNpMonFeatBrsDevTSEntry 8 } telProdNpMonFeatBrsDevTSLastTx OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Last instant where a packet for this class was transmitted. (This parameter is for Teldat personnel use only)." ::= { telProdNpMonFeatBrsDevTSEntry 9 } telProdNpMonFeatBrsDevTSThroughput OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Average throughput for a class." ::= { telProdNpMonFeatBrsDevTSEntry 10 } -- Tabla que contiene la informacin relativa a traffic-shaping para cada clase -- dentro de cada uno de los DLCIs de los interfaces Frame Relay configurados -- en el equipo con Reserva de Ancho de Banda. telProdNpMonFeatBrsFRCirTSTable OBJECT-TYPE SYNTAX SEQUENCE OF TelProdNpMonFeatBrsFRCirTSEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains information relative to traffic-shaping for each class within a Frame Relay circuit (DLCI) and for the whole circuit ('Global' row)." ::= { telProdNpMonFeatBrs 8 } telProdNpMonFeatBrsFRCirTSEntry OBJECT-TYPE SYNTAX TelProdNpMonFeatBrsFRCirTSEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry is comprised of several variables to store information relative to traffic-shaping for one class within a Frame Relay circuit (DLCI) or for the whole circuit ('Global' row)." INDEX { telProdNpMonFeatBrsFRCirTSIfc, telProdNpMonFeatBrsFRCirTSDlci, telProdNpMonFeatBrsFRCirTSClassNum } ::= { telProdNpMonFeatBrsFRCirTSTable 1 } TelProdNpMonFeatBrsFRCirTSEntry ::= SEQUENCE{ telProdNpMonFeatBrsFRCirTSIfc INTEGER, telProdNpMonFeatBrsFRCirTSDlci INTEGER, telProdNpMonFeatBrsFRCirTSClassNum INTEGER, telProdNpMonFeatBrsFRCirTSClear INTEGER, telProdNpMonFeatBrsFRCirTSClassName DisplayString, telProdNpMonFeatBrsFRCirTSCir INTEGER, telProdNpMonFeatBrsFRCirTSBurst INTEGER, telProdNpMonFeatBrsFRCirTSState INTEGER, telProdNpMonFeatBrsFRCirTSQueued INTEGER, telProdNpMonFeatBrsFRCirTSLastTx INTEGER, telProdNpMonFeatBrsFRCirTSThroughput INTEGER } telProdNpMonFeatBrsFRCirTSIfc OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "First index: interface number." ::= { telProdNpMonFeatBrsFRCirTSEntry 1 } telProdNpMonFeatBrsFRCirTSDlci OBJECT-TYPE SYNTAX INTEGER(16..1007) ACCESS read-only STATUS mandatory DESCRIPTION "Second index: Frame Relay circuit number (DLCI)." ::= { telProdNpMonFeatBrsFRCirTSEntry 2 } telProdNpMonFeatBrsFRCirTSClassNum OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Third index: class order within the Frame Relay circuit (DLCI)." ::= { telProdNpMonFeatBrsFRCirTSEntry 3 } telProdNpMonFeatBrsFRCirTSClear OBJECT-TYPE SYNTAX INTEGER{ delete(1), ok(2), error(3), undefined(4) } ACCESS read-write STATUS mandatory DESCRIPTION "This variable is used to make a clear operation: when it is set to 1 (delete), a clear command is executed, starting the measure of the throughput in this moment. The throughput measuring will only take into account those packets which are transmitted after this instant. In reading operations (GET) this variable will show the result of last clear operation attempt: the value is 2 (ok) if clear operation was performed succesfully, 3 (error) if an error ocurred and 4 (undefined) if no clear operations have been made yet." ::= { telProdNpMonFeatBrsFRCirTSEntry 4 } telProdNpMonFeatBrsFRCirTSClassName OBJECT-TYPE SYNTAX DisplayString(SIZE(0..9)) ACCESS read-only STATUS mandatory DESCRIPTION "Class name." ::= { telProdNpMonFeatBrsFRCirTSEntry 5 } telProdNpMonFeatBrsFRCirTSCir OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Maximum average permitted throughput (0 indicates there is no limit)." ::= { telProdNpMonFeatBrsFRCirTSEntry 6 } telProdNpMonFeatBrsFRCirTSBurst OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Currently used burst size (in bits)." ::= { telProdNpMonFeatBrsFRCirTSEntry 7 } telProdNpMonFeatBrsFRCirTSState OBJECT-TYPE SYNTAX INTEGER{ congested(1), bursting(2), ready(3) } ACCESS read-only STATUS mandatory DESCRIPTION "There are three possible states: (1) congested, (2) bursting, (3) ready. Transmission cannot be executed when a class or an interface is congested; transmission is possible in any other state." ::= { telProdNpMonFeatBrsFRCirTSEntry 8 } telProdNpMonFeatBrsFRCirTSQueued OBJECT-TYPE SYNTAX INTEGER{ yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates if this class is queued: when a class is queued, there is traffic to be transmitted." ::= { telProdNpMonFeatBrsFRCirTSEntry 9 } telProdNpMonFeatBrsFRCirTSLastTx OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Last instant where a packet for this class was transmitted. (This parameter is for Teldat personnel use only)." ::= { telProdNpMonFeatBrsFRCirTSEntry 10 } telProdNpMonFeatBrsFRCirTSThroughput OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Average throughput for a class." ::= { telProdNpMonFeatBrsFRCirTSEntry 11 } -- Tabla que contiene la informacin relativa a traffic-shaping usado para -- level-indicator en cada clase o a nivel global dentro de cada interfaz -- configurado en el equipo con Reserva de Ancho de Banda. telProdNpMonFeatBrsDevTSLvlIndTable OBJECT-TYPE SYNTAX SEQUENCE OF TelProdNpMonFeatBrsDevTSLvlIndEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains information relative to traffic-shaping used for level-indicator for each class and for the whole interface ('Global' row)." ::= { telProdNpMonFeatBrs 9 } telProdNpMonFeatBrsDevTSLvlIndEntry OBJECT-TYPE SYNTAX TelProdNpMonFeatBrsDevTSLvlIndEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry is comprised of several variables to store information relative to traffic-shaping for level-indicator for one class within an interface or for the whole interface ('Global' row)." INDEX { telProdNpMonFeatBrsDevTSLvlIndIfc, telProdNpMonFeatBrsDevTSLvlIndClassNum } ::= { telProdNpMonFeatBrsDevTSLvlIndTable 1 } TelProdNpMonFeatBrsDevTSLvlIndEntry ::= SEQUENCE{ telProdNpMonFeatBrsDevTSLvlIndIfc INTEGER, telProdNpMonFeatBrsDevTSLvlIndClassNum INTEGER, telProdNpMonFeatBrsDevTSLvlIndClear INTEGER, telProdNpMonFeatBrsDevTSLvlIndClassName DisplayString, telProdNpMonFeatBrsDevTSLvlIndCir INTEGER, telProdNpMonFeatBrsDevTSLvlIndBurst INTEGER, telProdNpMonFeatBrsDevTSLvlIndState INTEGER, telProdNpMonFeatBrsDevTSLvlIndQueued INTEGER, telProdNpMonFeatBrsDevTSLvlIndLastTx INTEGER, telProdNpMonFeatBrsDevTSLvlIndThroughput INTEGER } telProdNpMonFeatBrsDevTSLvlIndIfc OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "First index: interface number." ::= { telProdNpMonFeatBrsDevTSLvlIndEntry 1 } telProdNpMonFeatBrsDevTSLvlIndClassNum OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Second index: class order within the interface." ::= { telProdNpMonFeatBrsDevTSLvlIndEntry 2 } telProdNpMonFeatBrsDevTSLvlIndClear OBJECT-TYPE SYNTAX INTEGER{ delete(1), ok(2), error(3), undefined(4) } ACCESS read-write STATUS mandatory DESCRIPTION "This variable is used to make a clear operation: when it is set to 1 (delete), a clear command is executed, starting the measure of the throughput in this moment. The throughput measuring will only take into account those packets which are transmitted after this instant. In reading operations (GET) this variable will show the result of last clear operation attempt: the value is 2 (ok) if clear operation was performed succesfully, 3 (error) if an error ocurred and 4 (undefined) if no clear operations have been made yet." ::= { telProdNpMonFeatBrsDevTSLvlIndEntry 3 } telProdNpMonFeatBrsDevTSLvlIndClassName OBJECT-TYPE SYNTAX DisplayString(SIZE(0..9)) ACCESS read-only STATUS mandatory DESCRIPTION "Class name." ::= { telProdNpMonFeatBrsDevTSLvlIndEntry 4 } telProdNpMonFeatBrsDevTSLvlIndCir OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Maximum average permitted throughput (0 indicates there is no limit)." ::= { telProdNpMonFeatBrsDevTSLvlIndEntry 5 } telProdNpMonFeatBrsDevTSLvlIndBurst OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Currently used burst size (in bits)." ::= { telProdNpMonFeatBrsDevTSLvlIndEntry 6 } telProdNpMonFeatBrsDevTSLvlIndState OBJECT-TYPE SYNTAX INTEGER{ congested(1), bursting(2), ready(3) } ACCESS read-only STATUS mandatory DESCRIPTION "There are three possible states: (1) congested, (2) bursting, (3) ready. A level-indicator is updated when a class or an interface becomes congested; when congestion ends, it comes back to previous state." ::= { telProdNpMonFeatBrsDevTSLvlIndEntry 7 } telProdNpMonFeatBrsDevTSLvlIndQueued OBJECT-TYPE SYNTAX INTEGER{ yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates if this class is queued: when a class is queued, there is traffic to be transmitted." ::= { telProdNpMonFeatBrsDevTSLvlIndEntry 8 } telProdNpMonFeatBrsDevTSLvlIndLastTx OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Last instant where a packet for this class was transmitted. (This parameter is for Teldat personnel use only)." ::= { telProdNpMonFeatBrsDevTSLvlIndEntry 9 } telProdNpMonFeatBrsDevTSLvlIndThroughput OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Average throughput for a class." ::= { telProdNpMonFeatBrsDevTSLvlIndEntry 10 } -- Tabla que contiene la informacin relativa a traffic-shaping usado para -- level-indicator en cada clase o a nivel global dentro de cada uno de -- los DLCIs de los interfaces Frame Relay configurados en el equipo con -- Reserva de Ancho de Banda. telProdNpMonFeatBrsFRCirTSLvlIndTable OBJECT-TYPE SYNTAX SEQUENCE OF TelProdNpMonFeatBrsFRCirTSLvlIndEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains information relative to traffic-shaping used for level-indicator for each class within a Frame Relay circuit (DLCI) and for the whole circuit ('Global' row)." ::= { telProdNpMonFeatBrs 10 } telProdNpMonFeatBrsFRCirTSLvlIndEntry OBJECT-TYPE SYNTAX TelProdNpMonFeatBrsFRCirTSLvlIndEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry is comprised of several variables to store information relative to traffic-shaping used for level-indicator for one class within a Frame Relay circuit (DLCI) or for the whole circuit ('Global' row)." INDEX { telProdNpMonFeatBrsFRCirTSLvlIndIfc, telProdNpMonFeatBrsFRCirTSLvlIndDlci, telProdNpMonFeatBrsFRCirTSLvlIndClassNum } ::= { telProdNpMonFeatBrsFRCirTSLvlIndTable 1 } TelProdNpMonFeatBrsFRCirTSLvlIndEntry ::= SEQUENCE{ telProdNpMonFeatBrsFRCirTSLvlIndIfc INTEGER, telProdNpMonFeatBrsFRCirTSLvlIndDlci INTEGER, telProdNpMonFeatBrsFRCirTSLvlIndClassNum INTEGER, telProdNpMonFeatBrsFRCirTSLvlIndClear INTEGER, telProdNpMonFeatBrsFRCirTSLvlIndClassName DisplayString, telProdNpMonFeatBrsFRCirTSLvlIndCir INTEGER, telProdNpMonFeatBrsFRCirTSLvlIndBurst INTEGER, telProdNpMonFeatBrsFRCirTSLvlIndState INTEGER, telProdNpMonFeatBrsFRCirTSLvlIndQueued INTEGER, telProdNpMonFeatBrsFRCirTSLvlIndLastTx INTEGER, telProdNpMonFeatBrsFRCirTSLvlIndThroughput INTEGER } telProdNpMonFeatBrsFRCirTSLvlIndIfc OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "First index: interface number." ::= { telProdNpMonFeatBrsFRCirTSLvlIndEntry 1 } telProdNpMonFeatBrsFRCirTSLvlIndDlci OBJECT-TYPE SYNTAX INTEGER(16..1007) ACCESS read-only STATUS mandatory DESCRIPTION "Second index: Frame Relay circuit number (DLCI)." ::= { telProdNpMonFeatBrsFRCirTSLvlIndEntry 2 } telProdNpMonFeatBrsFRCirTSLvlIndClassNum OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Third index: class order within the Frame Relay circuit (DLCI)." ::= { telProdNpMonFeatBrsFRCirTSLvlIndEntry 3 } telProdNpMonFeatBrsFRCirTSLvlIndClear OBJECT-TYPE SYNTAX INTEGER{ delete(1), ok(2), error(3), undefined(4) } ACCESS read-write STATUS mandatory DESCRIPTION "This variable is used to make a clear operation: when it is set to 1 (delete), a clear command is executed, starting the measure of the throughput in this moment. The throughput measuring will only take into account those packets which are transmitted after this instant. In reading operations (GET) this variable will show the result of last clear operation attempt: the value is 2 (ok) if clear operation was performed succesfully, 3 (error) if an error ocurred and 4 (undefined) if no clear operations have been made yet." ::= { telProdNpMonFeatBrsFRCirTSLvlIndEntry 4 } telProdNpMonFeatBrsFRCirTSLvlIndClassName OBJECT-TYPE SYNTAX DisplayString(SIZE(0..9)) ACCESS read-only STATUS mandatory DESCRIPTION "Class name." ::= { telProdNpMonFeatBrsFRCirTSLvlIndEntry 5 } telProdNpMonFeatBrsFRCirTSLvlIndCir OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Maximum average permitted throughput (0 indicates there is no limit)." ::= { telProdNpMonFeatBrsFRCirTSLvlIndEntry 6 } telProdNpMonFeatBrsFRCirTSLvlIndBurst OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Currently used burst size (in bits)." ::= { telProdNpMonFeatBrsFRCirTSLvlIndEntry 7 } telProdNpMonFeatBrsFRCirTSLvlIndState OBJECT-TYPE SYNTAX INTEGER{ congested(1), bursting(2), ready(3) } ACCESS read-only STATUS mandatory DESCRIPTION "There are three possible states: (1) congested, (2) bursting, (3) ready. A level-indicator is updated when a class or an interface becomes congested; when congestion ends, it comes back to previous state." ::= { telProdNpMonFeatBrsFRCirTSLvlIndEntry 8 } telProdNpMonFeatBrsFRCirTSLvlIndQueued OBJECT-TYPE SYNTAX INTEGER{ yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates if this class is queued: when a class is queued, there is traffic to be transmitted." ::= { telProdNpMonFeatBrsFRCirTSLvlIndEntry 9 } telProdNpMonFeatBrsFRCirTSLvlIndLastTx OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Last instant where a packet for this class was transmitted. (This parameter is for Teldat personnel use only)." ::= { telProdNpMonFeatBrsFRCirTSLvlIndEntry 10 } telProdNpMonFeatBrsFRCirTSLvlIndThroughput OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Average throughput for a class." ::= { telProdNpMonFeatBrsFRCirTSLvlIndEntry 11 } END