-- -- SYMMCOMMONPPSTOD.mib -- MIB generated by MG-SOFT Visual MIB Builder 2013 (64-bit) Version 9.0 Build 760 -- Monday, September 21, 2015 at 23:36:13 -- -- SYMMCOMMONPPSTOD.my -- MIB generated by MG-SOFT Visual MIB Builder Version 7.0 Build 209 -- Monday, July 18, 2011 at 13:55:58 -- -- SYMMCOMMONPPSTOD.my -- MIB generated by MG-SOFT Visual MIB Builder Version 7.0 Build 209 -- Friday, March 04, 2011 at 11:46:14 -- SYMMCOMMONPPSTOD DEFINITIONS ::= BEGIN IMPORTS entPhysicalIndex FROM ENTITY-MIB ifNumber, ifIndex FROM IF-MIB OBJECT-GROUP, MODULE-COMPLIANCE FROM SNMPv2-CONF Integer32, OBJECT-TYPE, MODULE-IDENTITY, OBJECT-IDENTITY FROM SNMPv2-SMI DisplayString, TEXTUAL-CONVENTION FROM SNMPv2-TC symmPhysicalSignal FROM SYMM-COMMON-SMI; -- 1.3.6.1.4.1.9070.1.2.5.2.3 -- Feb 01, 2011 at 00:00 GMT -- -- 1.3.6.1.4.1.9070.1.2.5.2.3 -- February 01, 2011 at 00:00 GMT -- 1.3.6.1.4.1.9070.1.2.5.2.3 symmPPSTOD MODULE-IDENTITY LAST-UPDATED "201509301433Z" -- September 30, 2015 at 14:33 GMT ORGANIZATION "Symmetricom" CONTACT-INFO "Symmetricom Technical Support 1-888-367-7966 toll free USA 1-408-428-7907 worldwide Support@symmetricom.com " DESCRIPTION "Symmetricom, Inc. Common PPS/TOD input/output status and configuration " ::= { symmPhysicalSignal 3 } -- -- Type definitions -- -- Type definitions -- EnaValue ::= INTEGER { enable(1), disable(2) } TODPortType ::= INTEGER { disable(0), normal(1), error(2) } TPModuleID ::= INTEGER { sys(1), imc(2), ioc1(3), ioc2(4), exp0(5), exp1(6), exp2(7), exp3(8), exp4(9), exp5(10), exp6(11), exp7(12), exp8(13), exp9(14) } OnValue ::= INTEGER { on(1), off(2) } TPOutputType ::= INTEGER { outputGeneral(1), output10Mhz(2), outputPPS(3) } TPOutputGeneration ::= INTEGER { warmup(1), freerun(2), fastlock(3), normal(4) } OutputFrameType ::= INTEGER { freq1544khz(1), freq2048khz(2), ccs(3), cas(4), d4(5), esf(6) } ActionApply ::= INTEGER { apply(1), nonapply(2) } OpMode ::= INTEGER { auto(1), manual(2) } ActiveValue ::= INTEGER { active(1), inactive(2) } InputQualityLevel ::= INTEGER { prcprs(1), unkstu(2), typeiist2(3), typei(4), typevtnc(5), typeiiist3e(6), typeivst3(7), opt3smc(8), dus(9) } InputPriority ::= INTEGER (1..4) YesValue ::= INTEGER { yes(1), no(2) } OkValue ::= INTEGER { ok(1), fault(2) } ValidValue ::= INTEGER { valid(1), invalid(2), nurture(3) } TODInputFrameType ::= INTEGER { chinaMobile(1), ntp4(2) } -- -- Textual conventions -- -- Textual conventions -- -- Textual conventions -- -- Textual conventions -- -- Textual conventions -- DateAndTime ::= TEXTUAL-CONVENTION DISPLAY-HINT "2d-1d-1d,1d:1d:1d.1d,1a1d:1d" STATUS current DESCRIPTION "A date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present." SYNTAX OCTET STRING (SIZE (8 | 11)) TLatAndLon ::= TEXTUAL-CONVENTION DISPLAY-HINT "1a1d:1d:1d.1d" STATUS current DESCRIPTION "antenna latitude and longitude specification. field octets contents range ----- ------ -------- ----- 1 1 +/-180 deg '+' / '-' 2 2 degree 0..180 3 3 minute 0..59 4 4 second 0..59 5 5 second fraction 0..99 +/- dd:mm:ss.ss " SYNTAX OCTET STRING (SIZE (5)) TAntHeight ::= TEXTUAL-CONVENTION DISPLAY-HINT "1a2d.1d" STATUS current DESCRIPTION "antenna height specification. field octets contents range ----- ------ -------- ----- 1 1 +/- '+' / '-' 2 2-3 meter 0..10000 3 4 meter fraction 0..99 +/- hh.hh " SYNTAX OCTET STRING (SIZE (4)) TLocalTimeOffset ::= TEXTUAL-CONVENTION DISPLAY-HINT "1a1d:1d" STATUS current DESCRIPTION "A local time offset specification. field octets contents range ----- ------ -------- ----- 1 1 direction from UTC '+' / '-' 2 2 hours from UTC* 0..13 3 3 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - The hours range is 0..13 For example, the -6 local time offset would be displayed as: -6:0 " SYNTAX OCTET STRING (SIZE (3)) TSsm ::= TEXTUAL-CONVENTION DISPLAY-HINT "x" STATUS current DESCRIPTION "The ssm hex code" SYNTAX INTEGER (0..255) -- -- Node definitions -- -- Node definitions -- -- 1.3.6.1.4.1.9070.1.2.5.2.3.1 -- 1.3.6.1.4.1.9070.1.2.5.2.3.1 ppstodInput OBJECT IDENTIFIER ::= { symmPPSTOD 1 } -- Input PPS-TOD sub-tree -- 1.3.6.1.4.1.9070.1.2.5.2.3.1.1 -- 1.3.6.1.4.1.9070.1.2.5.2.3.1.1 ppstodInputStatus OBJECT IDENTIFIER ::= { ppstodInput 1 } -- 1.3.6.1.4.1.9070.1.2.5.2.3.1.1.1 -- 1.3.6.1.4.1.9070.1.2.5.2.3.1.1.1 ppstodInputStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF PpstodInputStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." ::= { ppstodInputStatus 1 } -- 1.3.6.1.4.1.9070.1.2.5.2.3.1.1.1.1 -- 1.3.6.1.4.1.9070.1.2.5.2.3.1.1.1.1 ppstodInputStatusEntry OBJECT-TYPE SYNTAX PpstodInputStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." INDEX { ifIndex, ppstodInputStatusIndex } ::= { ppstodInputStatusTable 1 } PpstodInputStatusEntry ::= SEQUENCE { ppstodInputStatusIndex Integer32, ppstodInputPortStatus TODPortType, ppstodInputPPSStatus DisplayString, ppstodInputPhaseOffset DisplayString, ppstodInputClockSourceType DisplayString, ppstodInputClockSourceStatus DisplayString, ppstodInputAccuracy DisplayString, ppstodInputAlarm DisplayString } -- 1.3.6.1.4.1.9070.1.2.5.2.3.1.1.1.1.1 -- 1.3.6.1.4.1.9070.1.2.5.2.3.1.1.1.1.1 ppstodInputStatusIndex OBJECT-TYPE SYNTAX Integer32 (1..10000) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." ::= { ppstodInputStatusEntry 1 } -- 1.3.6.1.4.1.9070.1.2.5.2.3.1.1.1.1.2 -- 1.3.6.1.4.1.9070.1.2.5.2.3.1.1.1.1.2 ppstodInputPortStatus OBJECT-TYPE SYNTAX TODPortType MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { ppstodInputStatusEntry 2 } -- 1.3.6.1.4.1.9070.1.2.5.2.3.1.1.1.1.3 -- 1.3.6.1.4.1.9070.1.2.5.2.3.1.1.1.1.3 ppstodInputPPSStatus OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { ppstodInputStatusEntry 3 } -- 1.3.6.1.4.1.9070.1.2.5.2.3.1.1.1.1.4 -- 1.3.6.1.4.1.9070.1.2.5.2.3.1.1.1.1.4 ppstodInputPhaseOffset OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { ppstodInputStatusEntry 4 } -- 1.3.6.1.4.1.9070.1.2.5.2.3.1.1.1.1.5 -- 1.3.6.1.4.1.9070.1.2.5.2.3.1.1.1.1.5 ppstodInputClockSourceType OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { ppstodInputStatusEntry 5 } -- 1.3.6.1.4.1.9070.1.2.5.2.3.1.1.1.1.6 -- 1.3.6.1.4.1.9070.1.2.5.2.3.1.1.1.1.6 ppstodInputClockSourceStatus OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { ppstodInputStatusEntry 6 } -- 1.3.6.1.4.1.9070.1.2.5.2.3.1.1.1.1.7 -- 1.3.6.1.4.1.9070.1.2.5.2.3.1.1.1.1.7 ppstodInputAccuracy OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { ppstodInputStatusEntry 7 } -- 1.3.6.1.4.1.9070.1.2.5.2.3.1.1.1.1.8 -- 1.3.6.1.4.1.9070.1.2.5.2.3.1.1.1.1.8 ppstodInputAlarm OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { ppstodInputStatusEntry 8 } -- 1.3.6.1.4.1.9070.1.2.5.2.3.1.2 -- 1.3.6.1.4.1.9070.1.2.5.2.3.1.2 ppstodInputConfig OBJECT IDENTIFIER ::= { ppstodInput 2 } -- 1.3.6.1.4.1.9070.1.2.4.6.3.5.2 -- 1.3.6.1.4.1.9070.1.2.4.6.3.5.2 -- 1.3.6.1.4.1.9070.1.2.4.6.3.5.2 -- 1.3.6.1.4.1.9070.1.2.5.2.3.1.2.1 -- 1.3.6.1.4.1.9070.1.2.5.2.3.1.2.1 ppstodInputTable OBJECT-TYPE SYNTAX SEQUENCE OF PpstodInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The pps-tod configuration table." ::= { ppstodInputConfig 1 } -- 1.3.6.1.4.1.9070.1.2.4.6.3.5.2.1 -- 1.3.6.1.4.1.9070.1.2.4.6.3.5.2.1 -- 1.3.6.1.4.1.9070.1.2.4.6.3.5.2.1 -- 1.3.6.1.4.1.9070.1.2.5.2.3.1.2.1.1 -- 1.3.6.1.4.1.9070.1.2.5.2.3.1.2.1.1 ppstodInputEntry OBJECT-TYPE SYNTAX PpstodInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The entry of pps-tod table." INDEX { ifIndex, ppstodInputIndex } ::= { ppstodInputTable 1 } PpstodInputEntry ::= SEQUENCE { ppstodInputIndex Integer32, ppstodInputCableDelay Integer32, ppstodInputFormat TODInputFrameType, ppstodInputManualLeapSeconds Integer32 } -- 1.3.6.1.4.1.9070.1.2.5.2.3.1.2.1.1.1 ppstodInputIndex OBJECT-TYPE SYNTAX Integer32 (1..1000) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." ::= { ppstodInputEntry 1 } -- 1.3.6.1.4.1.9070.1.2.4.6.3.5.2.1.9 -- 1.3.6.1.4.1.9070.1.2.4.6.3.5.2.1.9 -- 1.3.6.1.4.1.9070.1.2.4.6.3.5.2.1.9 -- 1.3.6.1.4.1.9070.1.2.5.2.3.1.2.1.1.5 -- 1.3.6.1.4.1.9070.1.2.5.2.3.1.2.1.1.5 ppstodInputCableDelay OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The input cable delay value. The valid setting is 0-999999. " ::= { ppstodInputEntry 5 } -- 1.3.6.1.4.1.9070.1.2.5.2.3.1.2.1.1.6 ppstodInputFormat OBJECT-TYPE SYNTAX TODInputFrameType MAX-ACCESS read-write STATUS current DESCRIPTION "TOD input format can be following chinaMobile(1) NTP-4(2) NotAvailable(0)" ::= { ppstodInputEntry 6 } -- 1.3.6.1.4.1.9070.1.2.5.2.3.1.2.1.1.7 ppstodInputManualLeapSeconds OBJECT-TYPE SYNTAX Integer32 (20..255) MAX-ACCESS read-write STATUS current DESCRIPTION "ManualLeap second" ::= { ppstodInputEntry 7 } -- Output PPS-TOD sub-tree -- 1.3.6.1.4.1.9070.1.2.5.2.3.2 -- 1.3.6.1.4.1.9070.1.2.5.2.3.2 ppstodOutput OBJECT IDENTIFIER ::= { symmPPSTOD 2 } -- 1.3.6.1.4.1.9070.1.2.5.2.3.2.1 -- 1.3.6.1.4.1.9070.1.2.5.2.3.2.1 ppstodOutputStatus OBJECT IDENTIFIER ::= { ppstodOutput 1 } -- 1.3.6.1.4.1.9070.1.2.5.2.3.2.2 -- 1.3.6.1.4.1.9070.1.2.5.2.3.2.2 ppstodOutputConfig OBJECT IDENTIFIER ::= { ppstodOutput 2 } -- 1.3.6.1.4.1.9070.1.2.4.8.1.6 -- 1.3.6.1.4.1.9070.1.2.4.6.1.1.6 -- 1.3.6.1.4.1.9070.1.2.4.6.1.1.6 -- 1.3.6.1.4.1.9070.1.2.5.2.3.3 -- 1.3.6.1.4.1.9070.1.2.5.2.3.3 ppstodConformance OBJECT-IDENTITY STATUS current DESCRIPTION "This subtree contains conformance statements for the Symmetricom PPS-TOD MIB. " ::= { symmPPSTOD 3 } -- 1.3.6.1.4.1.9070.1.2.4.8.1.6.1 -- 1.3.6.1.4.1.9070.1.2.4.6.1.1.6.1 -- 1.3.6.1.4.1.9070.1.2.4.6.1.1.6.1 -- 1.3.6.1.4.1.9070.1.2.5.2.3.3.1 -- 1.3.6.1.4.1.9070.1.2.5.2.3.3.1 ppstodCompliances OBJECT IDENTIFIER ::= { ppstodConformance 1 } -- 1.3.6.1.4.1.9070.1.2.5.2.3.3.1.1 -- this module -- 1.3.6.1.4.1.9070.1.2.5.2.3.3.1.1 ppstodBasicCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for SNMP entities which have PPS-TOD status and configuration of input/output." MODULE -- this module MANDATORY-GROUPS { ppstodInputConfigGroup } ::= { ppstodCompliances 1 } -- 1.3.6.1.4.1.9070.1.2.4.8.1.6.2 -- 1.3.6.1.4.1.9070.1.2.4.6.1.1.6.2 -- 1.3.6.1.4.1.9070.1.2.4.6.1.1.6.2 -- 1.3.6.1.4.1.9070.1.2.5.2.3.3.2 -- 1.3.6.1.4.1.9070.1.2.5.2.3.3.2 ppstodUocGroups OBJECT IDENTIFIER ::= { ppstodConformance 2 } -- 1.3.6.1.4.1.9070.1.2.5.2.3.3.2.1 -- 1.3.6.1.4.1.9070.1.2.5.2.3.3.2.1 ppstodInputConfigGroup OBJECT-GROUP OBJECTS { ppstodInputCableDelay, ppstodInputFormat, ppstodInputManualLeapSeconds, ppstodInputPortStatus, ppstodInputPPSStatus, ppstodInputClockSourceType, ppstodInputPhaseOffset, ppstodInputClockSourceStatus, ppstodInputAccuracy, ppstodInputAlarm } STATUS current DESCRIPTION "A collection of objects providing information applicable to PPS-TOD configuration group." ::= { ppstodUocGroups 1 } END -- -- SYMMCOMMONPPSTOD.my --