-- ***************************************************************** -- -- STN-PPTP.mib: -- Spring Tide Networks PPTP MIB file. -- -- -- Copyright (c) 1999, 2000 by Spring Tide Networks, Inc. -- ALL RIGHTS RESERVED -- -- ***************************************************************** STN-PPTP-MIB DEFINITIONS ::= BEGIN IMPORTS Integer32, Counter32, Gauge32, IpAddress, MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE FROM SNMPv2-SMI TEXTUAL-CONVENTION, DisplayString, RowStatus, TruthValue FROM SNMPv2-TC OBJECT-GROUP, MODULE-COMPLIANCE FROM SNMPv2-CONF InterfaceIndex FROM IF-MIB stnTmpProtocols FROM SPRING-TIDE-NETWORKS-SMI StnDomainMapType FROM SPRING-TIDE-NETWORKS-TC; stnPptp MODULE-IDENTITY LAST-UPDATED "0002160000Z" ORGANIZATION "Spring Tide Networks, Inc." CONTACT-INFO " Spring Tide Networks, Inc. Customer Service Postal: 3 Clock Tower Place Maynard, MA 01754 Tel: 1 888-786-4357 Email: stncs@springtidenet.com " DESCRIPTION "The MIB module that describes managed objects of general use by the Point-to-Point Transport Protocol." ::= { stnTmpProtocols 10 } -- -- Top Level STN PPTP MIB Objects -- stnPptpObjects OBJECT IDENTIFIER ::= { stnPptp 1 } stnPptpMibConformance OBJECT IDENTIFIER ::= { stnPptp 2 } stnPptpTraps OBJECT IDENTIFIER ::= { stnPptp 3 } -- -- Definitions of significant branches under stnPptpObjects -- stnPptpScalar OBJECT IDENTIFIER ::= { stnPptpObjects 1 } stnPptpConfig OBJECT IDENTIFIER ::= { stnPptpScalar 1 } stnPptpStats OBJECT IDENTIFIER ::= { stnPptpScalar 2 } -- -- Textual Conventions -- MilliSeconds ::= TEXTUAL-CONVENTION DISPLAY-HINT "d-3" STATUS current DESCRIPTION "A period of time measured in units of .001 of seconds when used in conjunction with the DISPLAY-HINT will show seconds and fractions of second with a resolution of .001 of a second." SYNTAX Integer32 (0..2147483646) -- -- The PPTP Scalar Configuration Group -- -- This group of objects is used to manage configuration -- of the PPTP protocol environment. stnPptpAdminState OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2), drain(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object defines the administrative state of this PPTP tunnel domain. Setting this object to 'disabled' causes all tunnels to be immediately disconnected and no further tunnels to be either initiated or accepted. " DEFVAL { enabled } ::= { stnPptpConfig 1 } -- -- The PPTP Scalar Status and Statistics Group -- -- This group of objects describe the current state and -- statistics of PPTP. stnPptpProtocolVersion OBJECT-TYPE SYNTAX OCTET STRING (SIZE(2..256)) MAX-ACCESS read-only STATUS current DESCRIPTION "Vector of supported PPTP protocol version and revision numbers. Supported versions are identified via a two octet pairing where the first octet indicates the version and the second octet contains the revision." ::= { stnPptpStats 1 } stnPptpVendorName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the Vendor name of the PPTP protocol stack." ::= { stnPptpStats 2 } stnPptpFirmwareRev OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object defines the firmware revision for the PPTP protocol stack." ::= { stnPptpStats 3 } -- -- The PPTP Domain Configuration Table -- -- This table contains objects that can be used to -- configure the operational characteristics of a tunnel -- domain. stnPptpDomainConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF StnPptpDomainConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The PPTP Domain configuration table." ::= { stnPptpObjects 2 } stnPptpDomainConfigEntry OBJECT-TYPE SYNTAX StnPptpDomainConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An PPTP Domain configuration entry. An entry in this table may correspond to a single endpoint or a group of tunnel endpoints." INDEX { stnPptpDomainConfigIdentifier } ::= { stnPptpDomainConfigTable 1 } StnPptpDomainConfigEntry ::= SEQUENCE { stnPptpDomainConfigIdentifier DisplayString, stnPptpDomainConfigAdminState INTEGER, stnPptpDomainConfigAuthentication INTEGER, stnPptpDomainConfigSecret OCTET STRING, stnPptpDomainConfigTunnelSecurity INTEGER, stnPptpDomainConfigTunnelHelloInterval Integer32, stnPptpDomainConfigTunnelIdleTimeout Integer32, stnPptpDomainConfigControlRWS Integer32, stnPptpDomainConfigControlRetransmissions Integer32, stnPptpDomainConfigPayloadSequencing TruthValue, stnPptpDomainConfigPayloadRWS Integer32, stnPptpDomainConfigDelayedAckTimeout MilliSeconds, stnPptpDomainConfigReassemblyTimeout MilliSeconds, stnPptpDomainConfigStatus RowStatus } stnPptpDomainConfigIdentifier OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object is not used." ::= { stnPptpDomainConfigEntry 1 } stnPptpDomainConfigAdminState OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2), drain(3) } MAX-ACCESS read-create STATUS current DESCRIPTION "This object is not used." DEFVAL { enabled } ::= { stnPptpDomainConfigEntry 2 } stnPptpDomainConfigAuthentication OBJECT-TYPE SYNTAX INTEGER { none(1), simple(2), challenge(3) } MAX-ACCESS read-create STATUS current DESCRIPTION "This object is not used" DEFVAL { none } ::= { stnPptpDomainConfigEntry 3 } stnPptpDomainConfigSecret OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) MAX-ACCESS read-create STATUS current DESCRIPTION "This object is not used " ::= { stnPptpDomainConfigEntry 4 } stnPptpDomainConfigTunnelSecurity OBJECT-TYPE SYNTAX INTEGER { none(1), other(2), ipSec(3) } MAX-ACCESS read-create STATUS current DESCRIPTION "This object is not used." DEFVAL { none } ::= { stnPptpDomainConfigEntry 5 } stnPptpDomainConfigTunnelHelloInterval OBJECT-TYPE SYNTAX Integer32 (0..3600) MAX-ACCESS read-create STATUS current DESCRIPTION "This object is not used." DEFVAL { 60 } ::= { stnPptpDomainConfigEntry 6 } stnPptpDomainConfigTunnelIdleTimeout OBJECT-TYPE SYNTAX Integer32 (0..86400) MAX-ACCESS read-create STATUS current DESCRIPTION "This object is not used." DEFVAL { 0 } ::= { stnPptpDomainConfigEntry 7 } stnPptpDomainConfigControlRWS OBJECT-TYPE SYNTAX Integer32 (1..64) MAX-ACCESS read-create STATUS current DESCRIPTION "This object is not used." DEFVAL { 4 } ::= { stnPptpDomainConfigEntry 8 } stnPptpDomainConfigControlRetransmissions OBJECT-TYPE SYNTAX Integer32 (0..32) MAX-ACCESS read-create STATUS current DESCRIPTION "This object is not used." DEFVAL { 4 } ::= { stnPptpDomainConfigEntry 9 } stnPptpDomainConfigPayloadSequencing OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "This object is not used." DEFVAL { false } ::= { stnPptpDomainConfigEntry 10 } stnPptpDomainConfigPayloadRWS OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-create STATUS current DESCRIPTION "This object is not used." DEFVAL { 0 } ::= { stnPptpDomainConfigEntry 11 } stnPptpDomainConfigDelayedAckTimeout OBJECT-TYPE SYNTAX MilliSeconds MAX-ACCESS read-create STATUS current DESCRIPTION "This object is not used." DEFVAL { 0 } ::= { stnPptpDomainConfigEntry 12 } stnPptpDomainConfigReassemblyTimeout OBJECT-TYPE SYNTAX MilliSeconds MAX-ACCESS read-create STATUS current DESCRIPTION "This object is not used." DEFVAL { 0 } ::= { stnPptpDomainConfigEntry 13 } stnPptpDomainConfigStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This object is not used." ::= { stnPptpDomainConfigEntry 14 } -- -- The PPTP Domain Status and Statistics Table -- -- This table contains objects that can be used to desribe -- the current status and statistics of a tunnel domain. stnPptpDomainStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF StnPptpDomainStatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The PPTP Domain Status and Statistics table." ::= { stnPptpObjects 3 } stnPptpDomainStatsEntry OBJECT-TYPE SYNTAX StnPptpDomainStatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An PPTP Domain Stats entry. An entry in this table may correspond to a single endpoint or a group of tunnel endpoints." INDEX { stnPptpDomainStatsIdentifier } ::= { stnPptpDomainStatsTable 1 } StnPptpDomainStatsEntry ::= SEQUENCE { stnPptpDomainStatsIdentifier DisplayString, stnPptpDomainStatsTotalTunnels Counter32, stnPptpDomainStatsFailedTunnels Counter32, stnPptpDomainStatsFailedAuthentications Counter32, stnPptpDomainStatsActiveTunnels Gauge32, stnPptpDomainStatsTotalSessions Counter32, stnPptpDomainStatsFailedSessions Counter32, stnPptpDomainStatsActiveSessions Gauge32, stnPptpDomainStatsControlRecvOctets Counter32, stnPptpDomainStatsControlRecvPackets Counter32, stnPptpDomainStatsControlSendOctets Counter32, stnPptpDomainStatsControlSendPackets Counter32, stnPptpDomainStatsPayloadRecvOctets Counter32, stnPptpDomainStatsPayloadRecvPackets Counter32, stnPptpDomainStatsPayloadRecvDiscards Counter32, stnPptpDomainStatsPayloadSendOctets Counter32, stnPptpDomainStatsPayloadSendPackets Counter32 } stnPptpDomainStatsIdentifier OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS not-accessible STATUS current DESCRIPTION "The identifier, usually in the form of a Domain Name (full or partial), describing a single tunnel endpoint or a domain of tunnel endpoints." ::= { stnPptpDomainStatsEntry 1 } stnPptpDomainStatsTotalTunnels OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object returns the total number of tunnels that have successfully reached the established state for this tunnel domain." ::= { stnPptpDomainStatsEntry 2 } stnPptpDomainStatsFailedTunnels OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object returns the number of tunnels that failed to reach the established state for this tunnel domain." ::= { stnPptpDomainStatsEntry 3 } stnPptpDomainStatsFailedAuthentications OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object is not used." ::= { stnPptpDomainStatsEntry 4 } stnPptpDomainStatsActiveTunnels OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object returns the number of tunnels that are currently active for this domain." ::= { stnPptpDomainStatsEntry 5 } stnPptpDomainStatsTotalSessions OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object returns the total number of sessions that have successfully reached the established state for this tunnel domain." ::= { stnPptpDomainStatsEntry 6 } stnPptpDomainStatsFailedSessions OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object returns the number of sessions that failed to reach the established state for this tunnel domain." ::= { stnPptpDomainStatsEntry 7 } stnPptpDomainStatsActiveSessions OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object returns the number of sessions that are currently active for this domain." ::= { stnPptpDomainStatsEntry 8 } stnPptpDomainStatsControlRecvOctets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object returns the number of control channel octets received for this tunnel domain." ::= { stnPptpDomainStatsEntry 9 } stnPptpDomainStatsControlRecvPackets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object returns the number of control packets received for this tunnel domain." ::= { stnPptpDomainStatsEntry 10 } stnPptpDomainStatsControlSendOctets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object returns the number of control channel octets that were transmitted to tunnel endpoints for this domain." ::= { stnPptpDomainStatsEntry 11 } stnPptpDomainStatsControlSendPackets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object returns the number of control packets that were transmitted to tunnel endpoints for this domain." ::= { stnPptpDomainStatsEntry 12 } stnPptpDomainStatsPayloadRecvOctets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object returns the number of payload channel octets that were received for this tunnel domain." ::= { stnPptpDomainStatsEntry 13 } stnPptpDomainStatsPayloadRecvPackets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object returns the number of payload packets that were received for this tunnel domain." ::= { stnPptpDomainStatsEntry 14 } stnPptpDomainStatsPayloadRecvDiscards OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object returns the number of received payload packets that were discarded by this this tunnel domain." ::= { stnPptpDomainStatsEntry 15 } stnPptpDomainStatsPayloadSendOctets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object returns the number of payload channel octets that were transmitted to tunnel peers within this tunnel domain." ::= { stnPptpDomainStatsEntry 16 } stnPptpDomainStatsPayloadSendPackets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object returns the number of payload packets that were transmitted to tunnel peers within this tunnel domain." ::= { stnPptpDomainStatsEntry 17 } -- -- The PPTP Tunnel Configuration Table -- -- This table contains objects that can be used to -- (re)configure the operational characteristics of a -- single PPTP tunnel. stnPptpTunnelConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF StnPptpTunnelConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The PPTP tunnel configuration table." ::= { stnPptpObjects 4 } stnPptpTunnelConfigEntry OBJECT-TYPE SYNTAX StnPptpTunnelConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A PPTP tunnel interface configuration entry." INDEX { stnPptpTunnelConfigIfIndex } ::= { stnPptpTunnelConfigTable 1 } StnPptpTunnelConfigEntry ::= SEQUENCE { stnPptpTunnelConfigIfIndex InterfaceIndex, stnPptpTunnelConfigAuthentication INTEGER, stnPptpTunnelConfigSecret OCTET STRING, stnPptpTunnelConfigSecurity INTEGER, stnPptpTunnelConfigHelloInterval Integer32, stnPptpTunnelConfigIdleTimeout Integer32, stnPptpTunnelConfigControlRWS Integer32, stnPptpTunnelConfigControlRetransmissions Integer32, stnPptpTunnelConfigPayloadSequencing TruthValue, stnPptpTunnelConfigPayloadRWS Integer32, stnPptpTunnelConfigDelayedAckTimeout MilliSeconds, stnPptpTunnelConfigReassemblyTimeout MilliSeconds, stnPptpTunnelConfigTransport INTEGER } stnPptpTunnelConfigIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "This value for this object is equal to the value of ifIndex of the Interfaces MIB for tunnel interfaces of type PPTP." ::= { stnPptpTunnelConfigEntry 1 } stnPptpTunnelConfigAuthentication OBJECT-TYPE SYNTAX INTEGER { none(1), simple(2), challenge(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object is not used." DEFVAL { none } ::= { stnPptpTunnelConfigEntry 2 } stnPptpTunnelConfigSecret OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) MAX-ACCESS read-write STATUS current DESCRIPTION "This object is not used." ::= { stnPptpTunnelConfigEntry 3 } stnPptpTunnelConfigSecurity OBJECT-TYPE SYNTAX INTEGER { none(1), other(2), ipsec(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object is not used." DEFVAL { none } ::= { stnPptpTunnelConfigEntry 4 } stnPptpTunnelConfigHelloInterval OBJECT-TYPE SYNTAX Integer32 (0..3600) MAX-ACCESS read-write STATUS current DESCRIPTION "This object is not used." DEFVAL { 60 } ::= { stnPptpTunnelConfigEntry 5 } stnPptpTunnelConfigIdleTimeout OBJECT-TYPE SYNTAX Integer32 (0..86400) MAX-ACCESS read-write STATUS current DESCRIPTION "This object is not used." DEFVAL { 0 } ::= { stnPptpTunnelConfigEntry 6 } stnPptpTunnelConfigControlRWS OBJECT-TYPE SYNTAX Integer32 (1..64) MAX-ACCESS read-write STATUS current DESCRIPTION "This object is not used." DEFVAL { 4 } ::= { stnPptpTunnelConfigEntry 7 } stnPptpTunnelConfigControlRetransmissions OBJECT-TYPE SYNTAX Integer32 (0..32) MAX-ACCESS read-write STATUS current DESCRIPTION "This object is not used." DEFVAL { 4 } ::= { stnPptpTunnelConfigEntry 8 } stnPptpTunnelConfigPayloadSequencing OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This object is not used." DEFVAL { false } ::= { stnPptpTunnelConfigEntry 9 } stnPptpTunnelConfigPayloadRWS OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "This object is not used." DEFVAL { 0 } ::= { stnPptpTunnelConfigEntry 10 } stnPptpTunnelConfigDelayedAckTimeout OBJECT-TYPE SYNTAX MilliSeconds MAX-ACCESS read-write STATUS current DESCRIPTION "This object is not used." DEFVAL { 0 } ::= { stnPptpTunnelConfigEntry 11 } stnPptpTunnelConfigReassemblyTimeout OBJECT-TYPE SYNTAX MilliSeconds MAX-ACCESS read-write STATUS current DESCRIPTION "This object is not used." DEFVAL { 0 } ::= { stnPptpTunnelConfigEntry 12 } stnPptpTunnelConfigTransport OBJECT-TYPE SYNTAX INTEGER { ipGre(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object defines the underlying transport media that is in use for this tunnel entry. Different tunnel transports may define MIB extensions to the PPTP tunnel table to realize the transport layer." ::= { stnPptpTunnelConfigEntry 13 } -- -- The PPTP Tunnel Status and Statisticss Table -- -- This table contains objects that can be used to describe -- the current status and statistics of a single PPTP tunnel. stnPptpTunnelStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF StnPptpTunnelStatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The PPTP tunnel status and statistics table." ::= { stnPptpObjects 5 } stnPptpTunnelStatsEntry OBJECT-TYPE SYNTAX StnPptpTunnelStatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An PPTP tunnel interface stats entry." INDEX { stnPptpTunnelStatsIfIndex } ::= { stnPptpTunnelStatsTable 1 } StnPptpTunnelStatsEntry ::= SEQUENCE { stnPptpTunnelStatsIfIndex InterfaceIndex, stnPptpTunnelStatsLocalTID Integer32, stnPptpTunnelStatsState INTEGER, stnPptpTunnelStatsInitiated INTEGER, stnPptpTunnelStatsRemoteHostName DisplayString, stnPptpTunnelStatsRemoteVendorName DisplayString, stnPptpTunnelStatsRemoteFirmwareRevision Integer32, stnPptpTunnelStatsRemoteProtocolVersion OCTET STRING, stnPptpTunnelStatsBearerCapabilities INTEGER, stnPptpTunnelStatsFramingCapabilities INTEGER, stnPptpTunnelStatsControlRecvPackets Counter32, stnPptpTunnelStatsControlSendPackets Counter32, stnPptpTunnelStatsTotalSessions Counter32, stnPptpTunnelStatsFailedSessions Counter32, stnPptpTunnelStatsActiveSessions Gauge32, stnPptpTunnelStatsLastResultCode Integer32, stnPptpTunnelStatsLastErrorCode Integer32, stnPptpTunnelStatsLastErrorMessage DisplayString } stnPptpTunnelStatsIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "This value for this object is equal to the value of ifIndex of the Interfaces MIB for tunnel interfaces of type PPTP." ::= { stnPptpTunnelStatsEntry 1 } stnPptpTunnelStatsLocalTID OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "This object contains the local tunnel Identifier." ::= { stnPptpTunnelStatsEntry 2 } stnPptpTunnelStatsState OBJECT-TYPE SYNTAX INTEGER { tunnelIdle(1), tunnelConnecting(2), tunnelEstablished(3), tunnelDisconnecting(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the current state of the control tunnel." ::= { stnPptpTunnelStatsEntry 3 } stnPptpTunnelStatsInitiated OBJECT-TYPE SYNTAX INTEGER { locally(1), remotely(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates whether the tunnel was initiated locally or by the remote tunnel peer." ::= { stnPptpTunnelStatsEntry 4 } stnPptpTunnelStatsRemoteHostName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This object contains the host name as discovered during the tunnel establishment phase " ::= { stnPptpTunnelStatsEntry 5 } stnPptpTunnelStatsRemoteVendorName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the vendor name of the peer's PPTP implementation. " ::= { stnPptpTunnelStatsEntry 6 } stnPptpTunnelStatsRemoteFirmwareRevision OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object contains the tunnel peer's firmware revision number." ::= { stnPptpTunnelStatsEntry 7 } stnPptpTunnelStatsRemoteProtocolVersion OBJECT-TYPE SYNTAX OCTET STRING (SIZE(2)) MAX-ACCESS read-only STATUS current DESCRIPTION "This object describes the protocol version and revision of the tunnel peers implementation. The first octet contains the protocol version. The second octet contains the protocol revision." ::= { stnPptpTunnelStatsEntry 8 } stnPptpTunnelStatsBearerCapabilities OBJECT-TYPE SYNTAX INTEGER { none(1), digital(2), analog(3), digitalAnalog(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object describes the Bearer Capabilities of the tunnel peer." ::= { stnPptpTunnelStatsEntry 9 } stnPptpTunnelStatsFramingCapabilities OBJECT-TYPE SYNTAX INTEGER { none(1), sync(2), async(3), syncAsync(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object describes the Framing Capabilities of the tunnel peer." ::= { stnPptpTunnelStatsEntry 10 } stnPptpTunnelStatsControlRecvPackets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object contains the number of control packets received on the tunnel." ::= { stnPptpTunnelStatsEntry 11 } stnPptpTunnelStatsControlSendPackets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object contains the number of control packets that were transmitted to the tunnel peer." ::= { stnPptpTunnelStatsEntry 12 } stnPptpTunnelStatsTotalSessions OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object contains the total number of sessions that this tunnel has successfully connected through to its tunnel peer since this tunnel was created." ::= { stnPptpTunnelStatsEntry 13 } stnPptpTunnelStatsFailedSessions OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object contains the total number of sessions that were initiated but failed to reach the established phase." ::= { stnPptpTunnelStatsEntry 14 } stnPptpTunnelStatsActiveSessions OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object contains the total number of sessions in the established state for this tunnel." ::= { stnPptpTunnelStatsEntry 15 } stnPptpTunnelStatsLastResultCode OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "This object contains the last value of the result code as described in the Result Code which caused the tunnel to disconnect." ::= { stnPptpTunnelStatsEntry 16 } stnPptpTunnelStatsLastErrorCode OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "This object contains the last value of the error code as described in the Result Code which caused the tunnel to disconnect." ::= { stnPptpTunnelStatsEntry 17 } stnPptpTunnelStatsLastErrorMessage OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This object contains the last value of the optional message as described in the Result Code which caused the tunnel to disconnect." ::= { stnPptpTunnelStatsEntry 18 } -- -- { stnPptpObjects 6 } reserved for future use -- -- -- The PPTP Session Status and Statistics Table -- -- This table contains the objects that can be used to -- describe the current status and statistics of a single -- PPTP tunneled session. stnPptpSessionStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF StnPptpSessionStatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The PPTP session status and statistics table." ::= { stnPptpObjects 7 } stnPptpSessionStatsEntry OBJECT-TYPE SYNTAX StnPptpSessionStatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An PPTP session interface stats entry." INDEX { stnPptpSessionStatsTunnelIfIndex, stnPptpSessionStatsLocalCID } ::= { stnPptpSessionStatsTable 1 } StnPptpSessionStatsEntry ::= SEQUENCE { stnPptpSessionStatsTunnelIfIndex InterfaceIndex, stnPptpSessionStatsHLIfIndex InterfaceIndex, stnPptpSessionStatsLocalCID Integer32, stnPptpSessionStatsRemoteCID Integer32, stnPptpSessionStatsUserName DisplayString, stnPptpSessionStatsState INTEGER, stnPptpSessionStatsCallType INTEGER, stnPptpSessionStatsCallSerialNumber Integer32, stnPptpSessionStatsTxConnectSpeed Integer32, stnPptpSessionStatsRxConnectSpeed Integer32, stnPptpSessionStatsCallBearerType INTEGER, stnPptpSessionStatsFramingType INTEGER, stnPptpSessionStatsPhysChanId Integer32, stnPptpSessionStatsDNIS DisplayString, stnPptpSessionStatsCLID DisplayString, stnPptpSessionStatsSubAddress DisplayString, stnPptpSessionStatsPrivateGroupID DisplayString, stnPptpSessionStatsLocalRWS Integer32, stnPptpSessionStatsRemoteInitialRWS Integer32, stnPptpSessionStatsRemotePPD Integer32, stnPptpSessionStatsRecvZLB Counter32, stnPptpSessionStatsOutSequence Counter32, stnPptpSessionStatsSendZLB Counter32, stnPptpSessionStatsAckTimeouts Counter32, stnPptpSesssionStatsCurrentRemoteRWS Gauge32, stnPptpSessionStatsSendSeq Integer32, stnPptpSessionStatsSendSeqAck Integer32, stnPptpSessionStatsRecvSeq Integer32, stnPptpSessionStatsRecvSeqAck Integer32 } stnPptpSessionStatsTunnelIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the sessions associated PPTP tunnel ifIndex value." ::= { stnPptpSessionStatsEntry 1 } stnPptpSessionStatsHLIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the ifIndex value of the interface that is either below (Lower) the tunnel (if this tunnel endpoint is a PAC) or above (Higher) the tunnel (if this tunnel endpoint is a PNS). For example this could be a DS0 ifIndex on a PAC or it would be the PPP ifIndex on the PNS." ::= { stnPptpSessionStatsEntry 2 } stnPptpSessionStatsLocalCID OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "This object contains the local call identifier for the session." ::= { stnPptpSessionStatsEntry 3 } stnPptpSessionStatsRemoteCID OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "This object is not used." ::= { stnPptpSessionStatsEntry 4 } stnPptpSessionStatsUserName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the peer session name on this interface. This is typically the login name of the remote user. If the user name is unknown to the local tunnel peer then this object will contain a null string." ::= { stnPptpSessionStatsEntry 5 } stnPptpSessionStatsState OBJECT-TYPE SYNTAX INTEGER { sessionIdle(1), sessionConnecting(2), sessionEstablished(3), sessionDisconnecting(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object contains the current state of the session." ::= { stnPptpSessionStatsEntry 6 } stnPptpSessionStatsCallType OBJECT-TYPE SYNTAX INTEGER { pacIncoming(1), pnsIncoming(2), pacOutgoing(3), pnsOutgoing(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the type of call and the role this tunnel peer is providing for this session. For example, pacIncoming(1) indicates that this tunnel peer is acting as a PAC and generated a Incoming-Call-Request to the tunnel peer (the PNS). Note that tunnel peers can be both PAC and PNS simultaneously." ::= { stnPptpSessionStatsEntry 7 } stnPptpSessionStatsCallSerialNumber OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object contains the serial number that has been assigned to this session." ::= { stnPptpSessionStatsEntry 8 } stnPptpSessionStatsTxConnectSpeed OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object returns the last known transmit baud rate for this session." ::= { stnPptpSessionStatsEntry 9 } stnPptpSessionStatsRxConnectSpeed OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object returns the last known receive baud rate for this session established." ::= { stnPptpSessionStatsEntry 10 } stnPptpSessionStatsCallBearerType OBJECT-TYPE SYNTAX INTEGER { none(1), digital(2), analog(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object describes the bearer type of this session." ::= { stnPptpSessionStatsEntry 11 } stnPptpSessionStatsFramingType OBJECT-TYPE SYNTAX INTEGER { none(1), sync(2), async(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object describes the framing type of this session." ::= { stnPptpSessionStatsEntry 12 } stnPptpSessionStatsPhysChanId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object contains the physical channel identifier for the session." ::= { stnPptpSessionStatsEntry 13 } stnPptpSessionStatsDNIS OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the Dialed Number Information String that the PAC obtained from the network for the session. If no DNIS was provided then a null string will be returned." ::= { stnPptpSessionStatsEntry 14 } stnPptpSessionStatsCLID OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the Calling Line ID that the PAC obtained from the network for the session. If no CLID was provided then a null string will be returned." ::= { stnPptpSessionStatsEntry 15 } stnPptpSessionStatsSubAddress OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the Sub Address that the PAC obtained from the network for the session. If no Sub Address was provided then a null string will be returned." ::= { stnPptpSessionStatsEntry 16 } stnPptpSessionStatsPrivateGroupID OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the Private Group Identifier used for this tunneled session. If no Private Group Identifier was provided then a null string will be returned." ::= { stnPptpSessionStatsEntry 17 } stnPptpSessionStatsLocalRWS OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "This object returns the local send window size for this session. " ::= { stnPptpSessionStatsEntry 18 } stnPptpSessionStatsRemoteInitialRWS OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "This object returns the initial remote send window size for this session. " ::= { stnPptpSessionStatsEntry 19 } stnPptpSessionStatsRemotePPD OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object contains the Packet Processing Delay for the session. " ::= { stnPptpSessionStatsEntry 20 } stnPptpSessionStatsRecvZLB OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object returns the total number of Zero Length Body acknowlegement payload packets received for this session." ::= { stnPptpSessionStatsEntry 21 } stnPptpSessionStatsOutSequence OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object returns the total number of packets received for this session which were received out of sequence." ::= { stnPptpSessionStatsEntry 22 } stnPptpSessionStatsSendZLB OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object returns the total number of Zero Length Body acknowledgement packets transmitted on this session." ::= { stnPptpSessionStatsEntry 23 } stnPptpSessionStatsAckTimeouts OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object returns the total number of acknowledgement timeouts seen on payload packets for this session." ::= { stnPptpSessionStatsEntry 24 } stnPptpSesssionStatsCurrentRemoteRWS OBJECT-TYPE SYNTAX Gauge32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "This object contains the current remote receive window size as determined by the local flow control mechanism employed." ::= { stnPptpSessionStatsEntry 25 } stnPptpSessionStatsSendSeq OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "This object contains the next send sequence number for for this session." ::= { stnPptpSessionStatsEntry 26 } stnPptpSessionStatsSendSeqAck OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "This object contains the send sequence number that the tunnel peer has acknowledged for the payload channel. The flow control state can be determined by subtracting the stnPptpSessionStatsSendSeq from stnPptpSessionStatsSendSeqAck and comparing this value to stnPptpSesssionStatsCurrentRemoteRWS." ::= { stnPptpSessionStatsEntry 27 } stnPptpSessionStatsRecvSeq OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "This object contains the next receive sequence number expected to be received on this session." ::= { stnPptpSessionStatsEntry 28 } stnPptpSessionStatsRecvSeqAck OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "This object contains the last receive sequence number that was acknowledged back to the tunnel peer for the session." ::= { stnPptpSessionStatsEntry 29 } -- -- The PPTP Tunnel Mapping Table -- -- This table is intended to assist management -- applications to quickly determine what the ifIndex -- value is for a given local tunnel identifier. stnPptpTunnelMapTable OBJECT-TYPE SYNTAX SEQUENCE OF StnPptpTunnelMapEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The PPTP Tunnel index mapping table." ::= { stnPptpObjects 8 } stnPptpTunnelMapEntry OBJECT-TYPE SYNTAX StnPptpTunnelMapEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An PPTP tunnel index map entry." INDEX { stnPptpTunnelMapLocalTID } ::= { stnPptpTunnelMapTable 1 } StnPptpTunnelMapEntry ::= SEQUENCE { stnPptpTunnelMapLocalTID Integer32, stnPptpTunnelMapIfIndex InterfaceIndex } stnPptpTunnelMapLocalTID OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "This object contains the local tunnel Identifier." ::= { stnPptpTunnelMapEntry 1 } stnPptpTunnelMapIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "This value for this object is equal to the value of ifIndex of the Interfaces MIB for tunnel interfaces of type PPTP." ::= { stnPptpTunnelMapEntry 2 } -- -- The PPTP Session Mapping Table -- -- This table is intended to assist management -- applications to quickly determine what the instance -- value is for a given upper or lower ifIndex. stnPptpSessionMapTable OBJECT-TYPE SYNTAX SEQUENCE OF StnPptpSessionMapEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The PPTP Session index mapping table." ::= { stnPptpObjects 9 } stnPptpSessionMapEntry OBJECT-TYPE SYNTAX StnPptpSessionMapEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An PPTP Session index map entry." INDEX { stnPptpSessionMapHLIfIndex } ::= { stnPptpSessionMapTable 1 } StnPptpSessionMapEntry ::= SEQUENCE { stnPptpSessionMapHLIfIndex InterfaceIndex, stnPptpSessionMapTunnelIfIndex InterfaceIndex, stnPptpSessionMapLocalCID Integer32 } stnPptpSessionMapHLIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the ifIndex value of the interface that is either below (Lower) the tunnel (if this tunnel endpoint is a PAC) or above (Higher) the tunnel (if this tunnel endpoint is a PNS). For example this could be a DS0 ifIndex on a PAC or it would be the PPP ifIndex on the PNS." ::= { stnPptpSessionMapEntry 1 } stnPptpSessionMapTunnelIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the sessions associated PPTP tunnel ifIndex value." ::= { stnPptpSessionMapEntry 2 } stnPptpSessionMapLocalCID OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "This object contains the local call identifier for the session." ::= { stnPptpSessionMapEntry 3 } -- -- The PPTP Domain Mapping Table -- stnPptpDomainMapTable OBJECT-TYPE SYNTAX SEQUENCE OF StnPptpDomainMapTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table provides a mapping between PPTP Domain identifiers, hostnames, and IP-ATM information" ::= { stnPptpObjects 10 } stnPptpDomainMapTableEntry OBJECT-TYPE SYNTAX StnPptpDomainMapTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry within the STN PPTP Map Table." INDEX { stnPptpDomainMapIdentifier } ::= { stnPptpDomainMapTable 1 } StnPptpDomainMapTableEntry ::= SEQUENCE { stnPptpDomainMapIdentifier DisplayString, stnPptpDomainMapHostName DisplayString, stnPptpDomainMapType StnDomainMapType, stnPptpDomainMapTypeInfo DisplayString } stnPptpDomainMapIdentifier OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS not-accessible STATUS current DESCRIPTION "PPTP Domain Identifier." ::= { stnPptpDomainMapTableEntry 1 } stnPptpDomainMapHostName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The hostname that maps to the PPTP Domain Identifier." ::= { stnPptpDomainMapTableEntry 2 } stnPptpDomainMapType OBJECT-TYPE SYNTAX StnDomainMapType MAX-ACCESS read-only STATUS current DESCRIPTION "Identifiers whether the PPTP Domain maps to an IP subnet or an ATM circuit." ::= { stnPptpDomainMapTableEntry 3 } stnPptpDomainMapTypeInfo OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Provides either IP or ATM specific display info." ::= { stnPptpDomainMapTableEntry 4 } -- -- conformance information -- stnPptpGroups OBJECT IDENTIFIER ::= { stnPptpMibConformance 1 } stnPptpCompliances OBJECT IDENTIFIER ::= { stnPptpMibConformance 2 } -- -- compliance statements -- stnPptpCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for SNMPv2 entities which implement the PPTP MIB." MODULE -- this module -- unconditionally mandatory groups MANDATORY-GROUPS { stnPptpConfigGroup, stnPptpStatsGroup } -- optional groups GROUP stnPptpDomainGroup DESCRIPTION "This group is optional for PPTP devices that desire to group tunnel endpoints into tunnel domains." GROUP stnPptpMappingGroup DESCRIPTION "This group is optional for PPTP devices that wish to provide index mapping." ::= { stnPptpCompliances 1 } -- units of conformance stnPptpConfigGroup OBJECT-GROUP OBJECTS { stnPptpAdminState, stnPptpTunnelConfigAuthentication, stnPptpTunnelConfigSecret, stnPptpTunnelConfigSecurity, stnPptpTunnelConfigHelloInterval, stnPptpTunnelConfigIdleTimeout, stnPptpTunnelConfigControlRWS, stnPptpTunnelConfigControlRetransmissions, stnPptpTunnelConfigPayloadSequencing, stnPptpTunnelConfigPayloadRWS, stnPptpTunnelConfigDelayedAckTimeout, stnPptpTunnelConfigReassemblyTimeout, stnPptpTunnelConfigTransport } STATUS current DESCRIPTION "A collection of objects providing configuration information of the PPTP protocol, tunnels and sessions." ::= { stnPptpGroups 1 } stnPptpStatsGroup OBJECT-GROUP OBJECTS { stnPptpProtocolVersion, stnPptpVendorName, stnPptpFirmwareRev, stnPptpTunnelStatsIfIndex, stnPptpTunnelStatsLocalTID, stnPptpTunnelStatsState, stnPptpTunnelStatsInitiated, stnPptpTunnelStatsRemoteHostName, stnPptpTunnelStatsRemoteVendorName, stnPptpTunnelStatsRemoteFirmwareRevision, stnPptpTunnelStatsRemoteProtocolVersion, stnPptpTunnelStatsBearerCapabilities, stnPptpTunnelStatsFramingCapabilities, stnPptpTunnelStatsControlRecvPackets, stnPptpTunnelStatsControlSendPackets, stnPptpTunnelStatsTotalSessions, stnPptpTunnelStatsFailedSessions, stnPptpTunnelStatsActiveSessions, stnPptpTunnelStatsLastResultCode, stnPptpTunnelStatsLastErrorCode, stnPptpTunnelStatsLastErrorMessage, stnPptpSessionStatsTunnelIfIndex, stnPptpSessionStatsHLIfIndex, stnPptpSessionStatsLocalCID, stnPptpSessionStatsRemoteCID, stnPptpSessionStatsUserName, stnPptpSessionStatsState, stnPptpSessionStatsCallType, stnPptpSessionStatsCallSerialNumber, stnPptpSessionStatsTxConnectSpeed, stnPptpSessionStatsRxConnectSpeed, stnPptpSessionStatsCallBearerType, stnPptpSessionStatsFramingType, stnPptpSessionStatsPhysChanId, stnPptpSessionStatsDNIS, stnPptpSessionStatsCLID, stnPptpSessionStatsSubAddress, stnPptpSessionStatsPrivateGroupID, stnPptpSessionStatsLocalRWS, stnPptpSessionStatsRemoteInitialRWS, stnPptpSessionStatsRemotePPD, stnPptpSessionStatsRecvZLB, stnPptpSessionStatsOutSequence, stnPptpSessionStatsSendZLB, stnPptpSessionStatsAckTimeouts, stnPptpSesssionStatsCurrentRemoteRWS, stnPptpSessionStatsSendSeq, stnPptpSessionStatsSendSeqAck, stnPptpSessionStatsRecvSeq, stnPptpSessionStatsRecvSeqAck } STATUS current DESCRIPTION "A collection of objects providing status and statistics of the PPTP protocol, tunnels and sessions." ::= { stnPptpGroups 2 } stnPptpDomainGroup OBJECT-GROUP OBJECTS { stnPptpDomainConfigAdminState, stnPptpDomainConfigAuthentication, stnPptpDomainConfigSecret, stnPptpDomainConfigTunnelSecurity, stnPptpDomainConfigTunnelHelloInterval, stnPptpDomainConfigTunnelIdleTimeout, stnPptpDomainConfigControlRWS, stnPptpDomainConfigControlRetransmissions, stnPptpDomainConfigPayloadSequencing, stnPptpDomainConfigPayloadRWS, stnPptpDomainConfigDelayedAckTimeout, stnPptpDomainConfigReassemblyTimeout, stnPptpDomainConfigStatus, stnPptpDomainStatsTotalTunnels, stnPptpDomainStatsFailedTunnels, stnPptpDomainStatsFailedAuthentications, stnPptpDomainStatsActiveTunnels, stnPptpDomainStatsTotalSessions, stnPptpDomainStatsFailedSessions, stnPptpDomainStatsActiveSessions, stnPptpDomainStatsControlRecvOctets, stnPptpDomainStatsControlRecvPackets, stnPptpDomainStatsControlSendOctets, stnPptpDomainStatsControlSendPackets, stnPptpDomainStatsPayloadRecvOctets, stnPptpDomainStatsPayloadRecvPackets, stnPptpDomainStatsPayloadRecvDiscards, stnPptpDomainStatsPayloadSendOctets, stnPptpDomainStatsPayloadSendPackets } STATUS current DESCRIPTION "A collection of objects providing configuration, status and statistics of PPTP tunnel domains." ::= { stnPptpGroups 4 } stnPptpMappingGroup OBJECT-GROUP OBJECTS { stnPptpTunnelMapLocalTID, stnPptpTunnelMapIfIndex, stnPptpSessionMapHLIfIndex, stnPptpSessionMapTunnelIfIndex, stnPptpSessionMapLocalCID } STATUS current DESCRIPTION "A collection of objects providing index mapping." ::= { stnPptpGroups 5 } END