-- ***************************************************************** -- -- STN-ATM-MIB.mib: -- Spring Tide Networks ATM MIB file. -- -- -- Copyright (c) 1999, 2000 by Spring Tide Networks, Inc. -- ALL RIGHTS RESERVED -- -- ***************************************************************** -- MIB Object definitions for Spring Tide Network ATM STN-ATM-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, Integer32, Counter32, IpAddress FROM SNMPv2-SMI TEXTUAL-CONVENTION, DisplayString, TruthValue FROM SNMPv2-TC MODULE-COMPLIANCE FROM SNMPv2-CONF InterfaceIndex FROM IF-MIB NSAPAddress FROM SPRING-TIDE-NETWORKS-TC stnSystems, stnNotification FROM SPRING-TIDE-NETWORKS-SMI stnRouterIndex FROM STN-ROUTER-MIB; stnAtm MODULE-IDENTITY LAST-UPDATED "0002160000Z" ORGANIZATION "Spring Tide Networks, Inc." CONTACT-INFO " Spring Tide Networks, Inc. Customer Service Postal: 3 Clock Tower Place Maynard, MA 01754 Tel: 1 888-786-4357 Email: stncs@springtidenet.com " DESCRIPTION "Initial version of this MIB module." ::= { stnSystems 6 } -- -- Top Level STN ATM MIB Objects -- stnAtmObjects OBJECT IDENTIFIER ::= { stnAtm 1 } stnAtmMibConformance OBJECT IDENTIFIER ::= { stnAtm 2 } stnAtmLinks OBJECT IDENTIFIER ::= { stnAtmObjects 1 } stnAtmCrossConns OBJECT IDENTIFIER ::= { stnAtmObjects 2 } stnAtmTrafficDescrs OBJECT IDENTIFIER ::= { stnAtmObjects 3 } stnAtmPorts OBJECT IDENTIFIER ::= { stnAtmObjects 4 } stnAtmTraces OBJECT IDENTIFIER ::= { stnAtmObjects 5 } stnAtmQos OBJECT IDENTIFIER ::= { stnAtmObjects 6 } stnAtmAddresses OBJECT IDENTIFIER ::= { stnAtmObjects 7 } stnAtmThresholds OBJECT IDENTIFIER ::= { stnAtmObjects 8 } stnAtmAcct OBJECT IDENTIFIER ::= { stnAtmObjects 9 } -- Mid-Level STN ATM MIB Objects stnVcLinks OBJECT IDENTIFIER ::= { stnAtmLinks 1 } stnVcCrossConns OBJECT IDENTIFIER ::= { stnAtmCrossConns 1 } stnVpCrossConns OBJECT IDENTIFIER ::= { stnAtmCrossConns 2 } stnAtmPortAttrs OBJECT IDENTIFIER ::= { stnAtmPorts 1 } stnAtmPortIlmi OBJECT IDENTIFIER ::= { stnAtmPorts 2 } stnAtmPortSignaling OBJECT IDENTIFIER ::= { stnAtmPorts 3 } stnAtmPortTraffic OBJECT IDENTIFIER ::= { stnAtmPorts 4 } stnTraceIps OBJECT IDENTIFIER ::= { stnAtmTraces 1 } stnTracePd OBJECT IDENTIFIER ::= { stnAtmTraces 2 } stnQosCLR OBJECT IDENTIFIER ::= { stnAtmQos 1 } stnQosCDV OBJECT IDENTIFIER ::= { stnAtmQos 2 } stnQosCTD OBJECT IDENTIFIER ::= { stnAtmQos 3 } -- Low-Level STN ATM MIB Objects stnAtmPortSigs OBJECT IDENTIFIER ::= { stnAtmPortSignaling 1 } stnAtmPortSigDurations OBJECT IDENTIFIER ::= { stnAtmPortSignaling 2 } stnAtmPortSigRetries OBJECT IDENTIFIER ::= { stnAtmPortSignaling 3 } -- Additional STN ATM MIB Textual Conventions VcLinkOperStatus ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Operational status of a VC Link." SYNTAX INTEGER { active(1), -- not-in-service(2), -- not-ready(3), -- create-and-go(4), -- create-and-wait(5), -- destroy(6) -- } VcCrossConnOperStatus ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Operational status of a VC cross connection." SYNTAX INTEGER { active(1), -- not-in-service(2), -- not-ready(3), -- create-and-go(4), -- create-and-wait(5), -- destroy(6) -- } TrafficDescrOperStatus ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Operational status of a traffic descriptor." SYNTAX INTEGER { active(1), -- not-in-service(2), -- not-ready(3), -- create-and-go(4), -- create-and-wait(5), -- destroy(6) -- } AtmPortOperStatus ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Operational status of an ATM port." SYNTAX INTEGER { active(1), -- inactive(2) -- } -- -- STN ATM VC Link Table -- stnVcLinkTable OBJECT-TYPE SYNTAX SEQUENCE OF StnVcLinkEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of VC Link entries." ::= { stnVcLinks 1 } stnVcLinkEntry OBJECT-TYPE SYNTAX StnVcLinkEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry contains information about a particular VC link." INDEX { stnVcLinkIfIndex, stnVcLinkVpi, stnVcLinkVci } ::= { stnVcLinkTable 1 } StnVcLinkEntry ::= SEQUENCE { stnVcLinkIfIndex InterfaceIndex, stnVcLinkVpi Integer32, stnVcLinkVci Integer32, stnVcLinkRcvTrafDescr Integer32, stnVcLinkXmtTrafDescr Integer32, stnVcLinkAalObjectsValid Integer32, stnVcLinkAalType INTEGER, stnVcLinkAal5XmtSDUSize Integer32, stnVcLinkAal5RcvSDUSize Integer32, stnVcLinkAal5EncapsType Integer32, stnVcLinkCastType INTEGER, stnVcLinkConnKind INTEGER, stnVcLinkAccEnabled TruthValue, stnVcLinkOAMMgmtEnabled TruthValue, stnVcLinkOAMXmtFrequency Integer32, stnVcLinkOAMRetryUpCount Integer32, stnVcLinkOAMRetryDownCount Integer32, stnVcLinkOAMRetryFrequency Integer32, stnVcLinkPppId Integer32, stnVcLinkOperStatus VcLinkOperStatus } stnVcLinkIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "The interface index represents a connection point on the switch fabric from a module or line card. It is calculated based on the slot and port of the module." ::= { stnVcLinkEntry 1 } stnVcLinkVpi OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The VPI value of the VPL. Note that the VPI=0 is not used for a VPL not associated with a VCL. The maximum VPI value cannot exceed the value allowable by the atmInterfaceMaxVpiBits." ::= { stnVcLinkEntry 2 } stnVcLinkVci OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The VCI value of the VCL. The maximum VCI value cannot exceed the value allowable by the atmInterfaceMaxVciBits." ::= { stnVcLinkEntry 3 } stnVcLinkRcvTrafDescr OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Receive traffic descriptor identifier for this VPL." ::= { stnVcLinkEntry 4 } stnVcLinkXmtTrafDescr OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Transmit traffic descriptor identifier for this VPL." ::= { stnVcLinkEntry 5 } stnVcLinkAalObjectsValid OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether the following AAL objects are valid (whether the local VCL end-point is also the VCC end-point). Transmit traffic descriptor identifier for this VPL." ::= { stnVcLinkEntry 6 } stnVcLinkAalType OBJECT-TYPE SYNTAX INTEGER { aal1(1), aal3-4(2), aal5(3), other(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "An instance of this object only exists when the local VCL end-point is also the VCC end-point, and AAL is in use. The type of AAL used on this VCC. The AAL type includes AAL1, AAL3/4, and AAL5. The other(4) may be used as a user-defined AAL type. The unknown type indicates that the AAL type cannot be determined." ::= { stnVcLinkEntry 7 } stnVcLinkAal5XmtSDUSize OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "An instance of this object only exists when the local VCL end-point is also the VCC end-point, and AAL5 is in use. The maximum AAL5 CPCS SDUsize in octets that is supported on the transmit direction of this VCC." DEFVAL { 4096 } ::= { stnVcLinkEntry 8 } stnVcLinkAal5RcvSDUSize OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "An instance of this object only exists when the local VCL end-point is also the VCC end-point, and AAL5 is in use. The maximum AAL5 CPCS SDU size in octets that is supported on the receive direction of this VCC." DEFVAL { 4096 } ::= { stnVcLinkEntry 9 } stnVcLinkAal5EncapsType OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "An instance of this object only exists when the local VCL end-point is also the VCC end-point, and AAL5 is in use. The type of data encapsulation used over the AAL5 SSCS layer. The definitions reference RFC 1483 Multiprotocol Encapsulation over ATM AAL5 and to the ATM Forum LAN Emulation specification." ::= { stnVcLinkEntry 10 } stnVcLinkCastType OBJECT-TYPE SYNTAX INTEGER { p2mpRoot(1), p2mpLeaf(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The type of topology of a connection (point- to-point, point-to-multipoint). In the case of point-to-multipoint, the orientation of this VPL in the connection. On a host, p2mpRoot indicates that the host is the root of the p2mp connection, p2mpLeaf indicates that the host is a leaf of the p2mp connection. On a switch, p2mpRoot indicates that cells received by the switching fabric from the interface are from the root of the p2mp connection, p2mpLeaf indicates that cells transmitted to the interface from the switching fabric are to the leaf of the p2mp connection." ::= { stnVcLinkEntry 11 } stnVcLinkConnKind OBJECT-TYPE SYNTAX INTEGER { pvc(1), svc-incomming(2), svc-outgoing(3), spvc-initiator(4), spvc-target(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "The use of call control. An spvcInitiator is always cross-connected to an svcOutgoing, and an spvcTarget is always cross-connected to an svcIncoming." ::= { stnVcLinkEntry 12 } stnVcLinkAccEnabled OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "ATM accounting is enabled for this VC Link." DEFVAL { false } ::= { stnVcLinkEntry 13 } stnVcLinkOAMMgmtEnabled OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "OAM management is enabled." DEFVAL { false } ::= { stnVcLinkEntry 14 } stnVcLinkOAMXmtFrequency OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of seconds between transmitting OAM loopback cells." DEFVAL { 5 } ::= { stnVcLinkEntry 15 } stnVcLinkOAMRetryUpCount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of consecutive end-to-end F5 OAM loopback cell responses that must be received in order to change a PVC state to up. Does not apply to SVCs." DEFVAL { 3 } ::= { stnVcLinkEntry 16 } stnVcLinkOAMRetryDownCount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of consecutive end-to-end F5 OAM loopback cell responses that are not received in order to change a PVC state to down or tear down an SVC." DEFVAL { 5 } ::= { stnVcLinkEntry 17 } stnVcLinkOAMRetryFrequency OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The frequency (in seconds) that end-to-end F5 loopback cells should be transmitted when a change in UP/DOWN state is being verified. For example, if a PVC is up and a loopback cell response is not received after the frequency (in seconds, then loopback cells are sent at the retry-frequency to verify whether or not the PVC is down." DEFVAL { 5 } ::= { stnVcLinkEntry 18 } stnVcLinkPppId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "PPP ID" ::= { stnVcLinkEntry 19 } stnVcLinkOperStatus OBJECT-TYPE SYNTAX VcLinkOperStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Operational status of the VC Link." ::= { stnVcLinkEntry 20 } -- -- STN ATM VC Cross Connection Table -- stnVcCrossConnTable OBJECT-TYPE SYNTAX SEQUENCE OF StnVcCrossConnEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of VC cross connection entries." ::= { stnVcCrossConns 1 } stnVcCrossConnEntry OBJECT-TYPE SYNTAX StnVcCrossConnEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry contains information about a particular VC cross connection." INDEX { stnVcCrossConnLowIfIndex, stnVcCrossConnLowVpi, stnVcCrossConnLowVci, stnVcCrossConnHighIfIndex, stnVcCrossConnHighVpi, stnVcCrossConnHighVci } ::= { stnVcCrossConnTable 1 } StnVcCrossConnEntry ::= SEQUENCE { stnVcCrossConnLowIfIndex InterfaceIndex, stnVcCrossConnLowVpi Integer32, stnVcCrossConnLowVci Integer32, stnVcCrossConnHighIfIndex InterfaceIndex, stnVcCrossConnHighVpi Integer32, stnVcCrossConnHighVci Integer32, stnVcCrossConnLowAutoAssign TruthValue, stnVcCrossConnHighAutoAssign TruthValue, stnVcCrossConnOperStatus VcCrossConnOperStatus } stnVcCrossConnLowIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this object is equal to MIB II's ifIndex value of the ATM interface port for this VP cross-connect. The term low implies that this ATM interface has the numerically lower ifIndex." ::= { stnVcCrossConnEntry 1 } stnVcCrossConnLowVpi OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this object is equal to the VPI value at the ATM interface associated with the VP cross-connect that is identified by LowIfIndex. The VPI value cannot exceed the number supported by the atmInterfaceMaxVpiBits at the low ATM interface port." ::= { stnVcCrossConnEntry 2 } stnVcCrossConnLowVci OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this object is equal to the VCI value at the ATM interface associated with the VC cross-connect that is identified by LowIfIndex. The VCI value cannot exceed the number supported by the atmInterfaceMaxVciBits at the low ATM interface port." ::= { stnVcCrossConnEntry 3 } stnVcCrossConnHighIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this object is equal to MIB II's ifIndex value of the ATM interface port for this VP cross-connect. The term low implies that this ATM interface has the numerically lower ifIndex." ::= { stnVcCrossConnEntry 4 } stnVcCrossConnHighVpi OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this object is equal to the VPI value at the ATM interface associated with the VP cross-connect that is identified by LowIfIndex. The VPI value cannot exceed the number supported by the atmInterfaceMaxVpiBits at the low ATM interface port." ::= { stnVcCrossConnEntry 5 } stnVcCrossConnHighVci OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this object is equal to the VCI value at the ATM interface associated with the VC cross-connect that is identified by LowIfIndex. The VCI value cannot exceed the number supported by the atmInterfaceMaxVciBits at the low ATM interface port. " ::= { stnVcCrossConnEntry 6 } stnVcCrossConnLowAutoAssign OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Controls low vpi/vci/ifIndex auto assignement to an ECF. If set to true MSM will attempt to dynamically auto assign the connection to an available ECF." DEFVAL { false } ::= { stnVcCrossConnEntry 7 } stnVcCrossConnHighAutoAssign OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Controls high vpi/vci/ifIndex auto assignement to an ECF. If set to true MSM will attempt to dynamically auto assign the connection to an available ECF." DEFVAL { false } ::= { stnVcCrossConnEntry 8 } stnVcCrossConnOperStatus OBJECT-TYPE SYNTAX VcCrossConnOperStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Operational status of the VC cross connection." ::= { stnVcCrossConnEntry 9 } -- -- STN ATM Traffic Descriptor Table -- stnTrafficDescrTable OBJECT-TYPE SYNTAX SEQUENCE OF StnTrafficDescrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of ATM traffic descriptor entries." ::= { stnAtmTrafficDescrs 1 } stnTrafficDescrEntry OBJECT-TYPE SYNTAX StnTrafficDescrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry contains information about a particular ATM traffic descriptor." INDEX { stnTrafDescrIndex } ::= { stnTrafficDescrTable 1 } StnTrafficDescrEntry ::= SEQUENCE { stnTrafDescrIndex Integer32, stnTrafDescrName OCTET STRING, stnTrafDescrType INTEGER, stnTrafDescrParam1 Integer32, stnTrafDescrParam2 Integer32, stnTrafDescrParam3 Integer32, stnTrafDescrParam4 Integer32, stnTrafDescrParam5 Integer32, stnTrafDescrQosClass INTEGER, stnTrafDescrServiceCategory INTEGER, stnTrafDescrFrameDiscard TruthValue, stnTrafDescrOperStatus TrafficDescrOperStatus, stnTrafDescrCommittedRate Integer32, stnTrafDescrMaximumRate Integer32 } stnTrafDescrIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this object identifies the row in the stnTrafficDescrTable." ::= { stnTrafficDescrEntry 1 } stnTrafDescrName OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "Text name assigned to this traffic descriptor." ::= { stnTrafficDescrEntry 2 } stnTrafDescrType OBJECT-TYPE SYNTAX INTEGER { no-td(1), -- no-clp-no-scr(2), -- clp-no-tag-no-scr(3), -- clp-tagging-no-scr(4), -- no-clp-scr(5), -- clp-no-tag-scr(6), -- clp-tagging-scr(7), -- clp-no-tag-mcr(8), -- clp-trans-no-scr(9), -- clp-trans-scr(10), -- no-clp-tag-no-scr(11) -- } MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this object identifies the type of ATM traffic descriptor. The type may indicate no traffic descriptor or traffic descriptor with one or more parameters. These parameters are specified as a parameter vector, in the corresponding instances of the objects: atmTrafDescrParam1, atmTrafDescrParam2, atmTrafDescrParam3, atmTrafDescrParam4, atmTrafDescrParam5 Type values are as follows: no-td no-clp-no-scr clp-no-ag-no-scr clp-agging-no-scr no-clp-scr clp-no-tag-scr clp-tagging-scr clp-no-tag-mcr clp-trans-no-scr clp-trans-scr no-clp-tag-no-scr" DEFVAL { no-td } ::= { stnTrafficDescrEntry 3 } stnTrafDescrParam1 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The first parameter of the ATM traffic descriptor used according to the value of atmTrafDescrType." DEFVAL { 0 } ::= { stnTrafficDescrEntry 4 } stnTrafDescrParam2 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The second parameter of the ATM traffic descriptor used according to the value of atmTrafDescrType." DEFVAL { 0 } ::= { stnTrafficDescrEntry 5 } stnTrafDescrParam3 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The third parameter of the ATM traffic descriptor used according to the value of atmTrafDescrType." DEFVAL { 0 } ::= { stnTrafficDescrEntry 6 } stnTrafDescrParam4 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The fourth parameter of the ATM traffic descriptor used according to the value of atmTrafDescrType." DEFVAL { 0 } ::= { stnTrafficDescrEntry 7 } stnTrafDescrParam5 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The fifth parameter of the ATM traffic descriptor used according to the value of atmTrafDescrType." DEFVAL { 0 } ::= { stnTrafficDescrEntry 8 } stnTrafDescrQosClass OBJECT-TYPE SYNTAX INTEGER { best-effort(0), service-class-a(1), service-class-b(2), service-class-c(3), service-class-d(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this object identifies the QoS Class. Four Service classes have been specified in the ATM Forum UNI Specification: Service Class A: Constant bit rate video and Circuit emulation. Service Class B: Variable bit rate video/audio. Service Class C: Connection-oriented data. Service Class D: Connectionless data. Four QoS classes numbered 1, 2, 3, and 4 have been specified with the aim to support service classes A, B, C, and D respectively. An unspecified QoS Class numbered '0' is used for best effort traffic." DEFVAL { best-effort } ::= { stnTrafficDescrEntry 9 } stnTrafDescrServiceCategory OBJECT-TYPE SYNTAX INTEGER { other(1), -- cbr(2), -- rt-vbr(3), -- nrt-vbr(4), -- abr(5), -- ubr(6) -- " } MAX-ACCESS read-only STATUS current DESCRIPTION "The ATM service category. Service categories are as follows: other, cbr, rt-vbr, nrt-vbr, abr, ubr" DEFVAL { ubr } ::= { stnTrafficDescrEntry 10 } stnTrafDescrFrameDiscard OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Whether the network should discard frames rather than cells." DEFVAL { false } ::= { stnTrafficDescrEntry 11 } stnTrafDescrOperStatus OBJECT-TYPE SYNTAX TrafficDescrOperStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Operational status of the traffic descriptor." ::= { stnTrafficDescrEntry 12 } stnTrafDescrCommittedRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The traffic rate in bits per second that the network is committed to transmit for VCs using this transmit traffic descriptor." DEFVAL { 0 } ::= { stnTrafficDescrEntry 13 } stnTrafDescrMaximumRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum traffic rate in bits per second that the network will transmit for VCs using this transmit traffic descriptor, if it differs from the committed rate." DEFVAL { 0 } ::= { stnTrafficDescrEntry 14 } -- -- STN ATM Trace IPS -- stnTraceIpsEnabled OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies whether IPS tracing is enabled." DEFVAL { false } ::= { stnTraceIps 1 } stnTraceIpsSize OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies the maximum IPS trace buffer size multipled by 1024. The IPS trace log file will wrap when it reaches the maximum. Default: 1000 x 1024 Lines" DEFVAL { 1000 } ::= { stnTraceIps 2 } stnTraceIpsFile OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies the IPS output path and file name. Changes to the path or filename take effect when IPS tracing is disabled and restarted (close file and open new)." ::= { stnTraceIps 3 } -- -- STN ATM Trace PD -- stnTracePdProblemEnabled OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies whether PD problem tracing is enabled." DEFVAL { true } ::= { stnTracePd 1 } stnTracePdExceptionEnabled OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies whether PD exception tracing is enabled." DEFVAL { true } ::= { stnTracePd 2 } stnTracePdAuditEnabled OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies whether PD audit tracing is enabled." DEFVAL { true } ::= { stnTracePd 3 } stnTracePdDeveloperEnabled OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies whether PD developer tracing is enabled." DEFVAL { false } ::= { stnTracePd 4 } stnTracePdSize OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies the maximum PD trace buffer size multipled by 1024. The PD trace log file will wrap when it reaches the maximum." DEFVAL { 25 } ::= { stnTracePd 5 } stnTracePdFile OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies the IPS output path and file name. Changes to the path or filename take effect when IPS tracing is disabled and restarted." ::= { stnTracePd 6 } -- -- STN ATM Qos CLR (Cell Loss Ratio) -- stnQosClass1CLR OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "QoS Class 1 cell loss ratio." ::= { stnQosCLR 1 } stnQosClass2CLR OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "QoS Class 2 cell loss ratio." ::= { stnQosCLR 2 } stnQosClass3CLR OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "QoS Class 3 cell loss ratio." ::= { stnQosCLR 3 } stnQosClass4CLR OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "QoS Class 4 cell loss ratio." ::= { stnQosCLR 4 } -- -- STN ATM Qos CDV (Cell Delay Variation) -- stnQosClass1CDV OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "QoS Class 1 cell delay variation." ::= { stnQosCDV 1 } stnQosClass2CDV OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "QoS Class 2 cell delay variation." ::= { stnQosCDV 2 } stnQosClass3CDV OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "QoS Class 3 cell delay variation." ::= { stnQosCDV 3 } stnQosClass4CDV OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "QoS Class 4 cell delay variation." ::= { stnQosCDV 4 } -- -- STN ATM Qos CTD (Cell Transfer Delay) -- stnQosClass1MaxCTD OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "QoS Class 1 cell transfer delay." ::= { stnQosCTD 1 } stnQosClass2MaxCTD OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "QoS Class 2 cell transfer delay." ::= { stnQosCTD 2 } stnQosClass3MaxCTD OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "QoS Class 3 cell delay transfer." ::= { stnQosCTD 3 } stnQosClass4MaxCTD OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "QoS Class 4 cell delay transfer." ::= { stnQosCTD 4 } -- -- STN ATM Port Attribute Table -- stnAtmPortAttrTable OBJECT-TYPE SYNTAX SEQUENCE OF StnAtmPortAttrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of ATM port attribute entries." ::= { stnAtmPortAttrs 1 } stnAtmPortAttrEntry OBJECT-TYPE SYNTAX StnAtmPortAttrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry contains information about a particular ATM port attribute entry." INDEX { stnAtmPortIfIndex } ::= { stnAtmPortAttrTable 1 } StnAtmPortAttrEntry ::= SEQUENCE { stnAtmPortIfIndex InterfaceIndex, stnAtmPortIfType Integer32, stnAtmPortIfState INTEGER, stnAtmPortEnabled TruthValue, stnAtmPortMinVccVpi INTEGER, stnAtmPortMaxVccVpi INTEGER, stnAtmPortMinVccVci INTEGER, stnAtmPortMaxVccVci INTEGER, stnAtmPortMinVpcVpi INTEGER, stnAtmPortMaxVpcVpi INTEGER, stnAtmPortMaxActivePaths INTEGER, stnAtmPortMaxActiveChannels INTEGER, stnAtmPortPVCAddress NSAPAddress, stnAtmPortSVCAddress NSAPAddress, stnAtmPortSigVpi Integer32, stnAtmPortSigVci Integer32, stnAtmPortSigEnabled TruthValue, stnAtmPortIlmiVpi Integer32, stnAtmPortIlmiVci Integer32, stnAtmPortIlmiEnabled TruthValue, stnAtmPortOamManagementEnabled TruthValue, stnAtmPortOamXmtFrequency Integer32, stnAtmPortOamRetryUpCount Integer32, stnAtmPortOamRetryDownCount Integer32, stnAtmPortOamRetryFrequency Integer32, stnAtmPortOperStatus AtmPortOperStatus } stnAtmPortIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "The interface index represents a connection point on the switch fabric from a module or line card. It is calculated based on the slot and port of the module." ::= { stnAtmPortAttrEntry 1 } stnAtmPortIfType OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The interface type of the connection point to the switch fabric. Values are: sonet(1), enet(2), epif(3), rim-enet(4)." ::= { stnAtmPortAttrEntry 2 } stnAtmPortIfState OBJECT-TYPE SYNTAX INTEGER (0..8) MAX-ACCESS read-only STATUS current DESCRIPTION "The interface state of the connection point to the switch fabric. Values are: not-present(0), detected(1), configured(2), up-non-redundant(3), up-redundant(4), down-non-redundant(5), down-redundant(6), failed(7), initialized(8)" ::= { stnAtmPortAttrEntry 3 } stnAtmPortEnabled OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Whether the ATM port is enabled." DEFVAL { true } ::= { stnAtmPortAttrEntry 4 } stnAtmPortMinVccVpi OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Minimum VPI used for Virtual Channel Circuits." DEFVAL { 0 } ::= { stnAtmPortAttrEntry 5 } stnAtmPortMaxVccVpi OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Maximum VPI used for Virtual Channel Circuits." DEFVAL { 0 } ::= { stnAtmPortAttrEntry 6 } stnAtmPortMinVccVci OBJECT-TYPE SYNTAX INTEGER (32..65554) MAX-ACCESS read-only STATUS current DESCRIPTION "Minimum VCI used for Virtual Channel Circuits. To avoid clashes with the reserved ATM VCI values (such as 5 for signaling and any other reserved values including Connection Manager VCs), the recommended value is 32. " DEFVAL { 32 } ::= { stnAtmPortAttrEntry 7 } stnAtmPortMaxVccVci OBJECT-TYPE SYNTAX INTEGER (32..65554) MAX-ACCESS read-only STATUS current DESCRIPTION "Maximum VCI used for Virtual Channel Circuits." DEFVAL { 4095 } ::= { stnAtmPortAttrEntry 8 } stnAtmPortMinVpcVpi OBJECT-TYPE SYNTAX INTEGER (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Minimum VPI used for Virtual Path Circuits. To avoid clashes with the reserved ATM VCCs values (such as 5 for signaling and any other reserved values including Connection Manager VCs), the recommended value is 1." DEFVAL { 1 } ::= { stnAtmPortAttrEntry 9 } stnAtmPortMaxVpcVpi OBJECT-TYPE SYNTAX INTEGER (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Maximum VCI used for Virtual Channel Circuits." DEFVAL { 255 } ::= { stnAtmPortAttrEntry 10 } stnAtmPortMaxActivePaths OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum number of active paths that can be active at any time on this port." DEFVAL { 127 } ::= { stnAtmPortAttrEntry 11 } stnAtmPortMaxActiveChannels OBJECT-TYPE SYNTAX INTEGER (0..65554) MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum number of virtual channels that can be active at any time on this port." DEFVAL { 4095 } ::= { stnAtmPortAttrEntry 12 } stnAtmPortPVCAddress OBJECT-TYPE SYNTAX NSAPAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The default configured PVC address information (20-byte NSAP address)." ::= { stnAtmPortAttrEntry 13 } stnAtmPortSVCAddress OBJECT-TYPE SYNTAX NSAPAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The default configured SVC address information (20-byte NSAP address)." ::= { stnAtmPortAttrEntry 14 } stnAtmPortSigVpi OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The VPI used for the signaling channel." DEFVAL { 0 } ::= { stnAtmPortAttrEntry 15 } stnAtmPortSigVci OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The VCI used for the signaling channel." DEFVAL { 5 } ::= { stnAtmPortAttrEntry 16 } stnAtmPortSigEnabled OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates if port will have a signaling stack." DEFVAL { false } ::= { stnAtmPortAttrEntry 17 } stnAtmPortIlmiVpi OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The VPI used for ILMI channel." DEFVAL { 0 } ::= { stnAtmPortAttrEntry 18 } stnAtmPortIlmiVci OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The VCI used for ILMI channel." DEFVAL { 16 } ::= { stnAtmPortAttrEntry 19 } stnAtmPortIlmiEnabled OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates if port will use ILMI." DEFVAL { false } ::= { stnAtmPortAttrEntry 20 } stnAtmPortOamManagementEnabled OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates if port is using OAM Management Procedures." DEFVAL { false } ::= { stnAtmPortAttrEntry 21 } stnAtmPortOamXmtFrequency OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates Frequency of OAM Transmit Cells." ::= { stnAtmPortAttrEntry 22 } stnAtmPortOamRetryUpCount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates OAM Cell Retry Up Count value." ::= { stnAtmPortAttrEntry 23 } stnAtmPortOamRetryDownCount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates OAM Cell Retry Down Count value." ::= { stnAtmPortAttrEntry 24 } stnAtmPortOamRetryFrequency OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates OAM Retry Frequency value." ::= { stnAtmPortAttrEntry 25 } stnAtmPortOperStatus OBJECT-TYPE SYNTAX AtmPortOperStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Operational status of the Port." ::= { stnAtmPortAttrEntry 26 } -- -- STN ATM Port ILMI Table -- stnAtmPortIlmiTable OBJECT-TYPE SYNTAX SEQUENCE OF StnAtmPortIlmiEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of ATM ILMI Port entries." ::= { stnAtmPortIlmi 1 } stnAtmPortIlmiEntry OBJECT-TYPE SYNTAX StnAtmPortIlmiEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry contains information about a particular ATM Port ILMI entry." INDEX { stnAtmPortIlmiIfIndex } ::= { stnAtmPortIlmiTable 1 } StnAtmPortIlmiEntry ::= SEQUENCE { stnAtmPortIlmiIfIndex InterfaceIndex, stnAtmPortIlmiVersion INTEGER, stnAtmPortIlmiNetworkOrientation INTEGER, stnAtmPortIlmiAutoNegotiate TruthValue, stnAtmPortIlmiPollInterval Integer32, stnAtmPortIlmiCheckConnectionInt Integer32, stnAtmPortIlmiInactivityFactor Integer32, stnAtmPortIlmiLocalConn INTEGER, stnAtmPortIlmiAdminStatus BITS, stnAtmPortIlmiEnterprise OBJECT IDENTIFIER, stnAtmPortIlmiLocalOid OBJECT IDENTIFIER, stnAtmPortIlmiNetPrefix OCTET STRING, stnAtmPortIlmiPrefixLen Integer32 } stnAtmPortIlmiIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "The interface index represents a connection point on the switch fabric from a module or line card. It is calculated based on the slot and port of the module." ::= { stnAtmPortIlmiEntry 1 } stnAtmPortIlmiVersion OBJECT-TYPE SYNTAX INTEGER { uni-3-dot-0(1), uni-3-dot-1(2), uni-4-dot-0(3), iisp-3-dot-1(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies the signaling stack protocol type to be used on this port. Valid options are: uni-3-dot-0 uni-3-dot-1 uni-4-dot-0 iisp-3-dot-1" DEFVAL { uni-3-dot-1 } ::= { stnAtmPortIlmiEntry 2 } stnAtmPortIlmiNetworkOrientation OBJECT-TYPE SYNTAX INTEGER { user(1), network(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies the ATM device type. Valid options are: user, network" DEFVAL { network } ::= { stnAtmPortIlmiEntry 3 } stnAtmPortIlmiAutoNegotiate OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates ILMI auto negotiation mode" DEFVAL { false } ::= { stnAtmPortIlmiEntry 4 } stnAtmPortIlmiPollInterval OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "ILMI connection poll interval (S) in seconds. When DC-ILMI is transmitting SNMP Get messages during the attempt to establish connectivity with the remote ILMI component, this parameter determines the time in seconds between transmissions. The default value is from the ATM Forum ILMI Specification Version 4.0: ILMI Connectivity Procedures (section 8.3.1)." DEFVAL { 1 } ::= { stnAtmPortIlmiEntry 5 } stnAtmPortIlmiCheckConnectionInt OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "ILMI check connection poll interval (T) in seconds. If connectivity checking is enabled (as spec by the value connect in the Admin_Status parameter below), this parameter specifies the time in seconds between successive transmissions of MIB Get msgs for the purpose of detecting loss of ILMI connectivity. If connectivity checking is not enabled, this parameter must be set to zero. The default value is from the ATM Forum ILMI Specification Version 4.0: ILMI Connectivity Procedures (section 8.3.1)." DEFVAL { 5 } ::= { stnAtmPortIlmiEntry 6 } stnAtmPortIlmiInactivityFactor OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "ILMI inactivity factor (K). The number of consecutive polls for which no response is received from the remote ILMI component before ILMI connectivity is assumed to be lost. The dflt value is from the ATM Forum ILMI Specification Version 4.0: ILMI Connectivity Procedures (section 8.3.1)." DEFVAL { 4 } ::= { stnAtmPortIlmiEntry 7 } stnAtmPortIlmiLocalConn OBJECT-TYPE SYNTAX INTEGER { other(1), public(2), private(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies whether the local end of the ILMI connection is advertised as a 'public' or 'private' ILMI device. Values are: other, public, private" DEFVAL { private } ::= { stnAtmPortIlmiEntry 8 } stnAtmPortIlmiAdminStatus OBJECT-TYPE SYNTAX BITS { std-ilmi(0), addr-reg(1), connect(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies which functions of DC-ILMI are enabled. The value std-ilmi must be specified; this value may be combined (using a bitwise OR) with one or more of the following values: std-ilmi - Standard ILMI functions are enabled. addr-reg - Address registration is enabled. connect - Connectivity chcking is enabled (DC-ILMI periodically sends a MIB Get request for the remote system's System ID, to ensure that it can still send and rcvd data on the ILMI connection). Default: (std-ilmi | addr-reg | connect)" ::= { stnAtmPortIlmiEntry 9 } stnAtmPortIlmiEnterprise OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS read-only STATUS current DESCRIPTION "Enterprise Object ID that DC-ILMI will use in building SNMP traps (or other generic MIB traps). This parameter can be used to identify the originator of the trap. The Object ID is specified as an array of unsigned long vals, as follows: The first entry in the array is the length of the array (the num of unsigned long values it contains, including the len value). The second entry in the array is an identifier specifying the Family type of the Object ID. This reps a prefix Object ID; the MIB Sub-Agent is responsible for matching this id with the dotted-decimal notation for this prefix. The remainder of the array gives the index part of the Object ID (the dotted-decimal notation from the end of the Family), with 1 unsigned long for each decimal number in this notation." ::= { stnAtmPortIlmiEntry 10 } stnAtmPortIlmiLocalOid OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS read-only STATUS current DESCRIPTION "Object ID identifying the local machine - the first 4 octets indicate the length of the object id. For example, the null object id (0.0), which should be used if no object id is specified, is encoded as 3, 0, 0." ::= { stnAtmPortIlmiEntry 11 } stnAtmPortIlmiNetPrefix OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..13)) MAX-ACCESS read-only STATUS current DESCRIPTION "Default network prefix. If the prefix length is non-zero, ILMI creates an entry in the ILMI NetPrefix Table for this prefix; otherwise the Net_Prefix parameter is not used." ::= { stnAtmPortIlmiEntry 12 } stnAtmPortIlmiPrefixLen OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The length of the default network prefix" ::= { stnAtmPortIlmiEntry 13 } -- -- STN ATM Port Signaling Table -- stnAtmPortSigTable OBJECT-TYPE SYNTAX SEQUENCE OF StnAtmPortSigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of ATM port signal entries." ::= { stnAtmPortSigs 1 } stnAtmPortSigEntry OBJECT-TYPE SYNTAX StnAtmPortSigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry contains information about a particular ATM port signal entry." INDEX { stnAtmPortSigIfIndex } ::= { stnAtmPortSigTable 1 } StnAtmPortSigEntry ::= SEQUENCE { stnAtmPortSigIfIndex InterfaceIndex, stnAtmPortSigVersion INTEGER, stnAtmPortSigNetworkOrientation INTEGER, stnAtmPortSigAssignVpiVci TruthValue, stnAtmPortSigVpSigType INTEGER, stnAtmPortSigParseMode INTEGER, stnAtmPortSigPrefCarrierPresent TruthValue, stnAtmPortSigPrefCarrier TruthValue } stnAtmPortSigIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "The interface index represents a connection point on the switch fabric from a module or line card. It is calculated based on the slot and port of the module." ::= { stnAtmPortSigEntry 1 } stnAtmPortSigVersion OBJECT-TYPE SYNTAX INTEGER { uni-3-dot-0(1), uni-3-dot-1(2), iisp-3-dot-1(3), pnni-1-dot-0(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies the signaling stack protocol type to be used on this port. Valid options are: UNI 3.0, UNI 3.1, IISP 3.1, PNNI 1.0" ::= { stnAtmPortSigEntry 2 } stnAtmPortSigNetworkOrientation OBJECT-TYPE SYNTAX INTEGER { user(1), network(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether the ATM device is of the user or network type. Valid values are: user, network" DEFVAL { network } ::= { stnAtmPortSigEntry 3 } stnAtmPortSigAssignVpiVci OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS not-accessible STATUS current DESCRIPTION "Specifies whether VPI/VCI assignment is the responsibility of the local signaling stack or of its partner stack. This parameter is used only for UNI 4.0. Values are: true - The local signaling stack is responsible for assigning VPIs/VCIs. false - The parent-signaling stack is responsible for assigning VPIs/VCIs." DEFVAL { true } ::= { stnAtmPortSigEntry 4 } stnAtmPortSigVpSigType OBJECT-TYPE SYNTAX INTEGER { associated-signaling(1), explicit-vpci(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies whether this signaling stack performs VP associated signaling: Valid options are: associated-signaling explicit-vpci" DEFVAL { explicit-vpci } ::= { stnAtmPortSigEntry 5 } stnAtmPortSigParseMode OBJECT-TYPE SYNTAX INTEGER { normal(1), strict(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies whether the message parser component of Sig should perform validity checking on the contents of received IEs. This element resides in the CCS MIB to allow software config of this behavior for compliance testing. Values are: normal - The parser checks the contents of the IEs the Sig uses and ensures that they are valid. For other IEs, it checks only the IE type and length and does not parse the contents. strict - The parser checks the contents of addit IEs as well as those used by Signaling and also checks for incorrect repetition of these add it IEs. Errors are handled in the same way as for the IEs used by sig (by sending a status message in UNI 3.1 or by following the IE instruction indicator in UNI 4.0)." DEFVAL { normal } ::= { stnAtmPortSigEntry 6 } stnAtmPortSigPrefCarrierPresent OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies whether a default prefrd carrier (transit network) is defined. Valid options are: true - the Default_Network_Id below defines which carr is the preferred carrier. false - no default preferred carrier is defined." DEFVAL { false } ::= { stnAtmPortSigEntry 7 } stnAtmPortSigPrefCarrier OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies the default preferred carrier. If stnAtmPortIlmiPrefCarrierPresent is set to false, this element is not used." ::= { stnAtmPortSigEntry 8 } -- -- STN ATM Port Signaling Timer Duration Table -- -- -- Signaling Timer Durations values milliseconds. For more info -- on the usage of these timers, refer to the appropriate UNI/NNI -- specification. -- stnAtmPortSigDurationTable OBJECT-TYPE SYNTAX SEQUENCE OF StnAtmPortSigDurationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of ATM Port Signaling Duration entries." ::= { stnAtmPortSigDurations 1 } stnAtmPortSigDurationEntry OBJECT-TYPE SYNTAX StnAtmPortSigDurationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry contains information about a particular ATM Port Signaling Duration entry." INDEX { stnAtmPortSigDurIfIndex } ::= { stnAtmPortSigDurationTable 1 } StnAtmPortSigDurationEntry ::= SEQUENCE { stnAtmPortSigDurIfIndex InterfaceIndex, stnAtmPortSigT301Duration Integer32, stnAtmPortSigT303Duration Integer32, stnAtmPortSigT306Duration Integer32, stnAtmPortSigT308Duration Integer32, stnAtmPortSigT309Duration Integer32, stnAtmPortSigT310Duration Integer32, stnAtmPortSigT313Duration Integer32, stnAtmPortSigT316Duration Integer32, stnAtmPortSigT317Duration Integer32, stnAtmPortSigT322Duration Integer32, stnAtmPortSigT331Duration Integer32, stnAtmPortSigT333Duration Integer32, stnAtmPortSigT397Duration Integer32, stnAtmPortSigT398Duration Integer32, stnAtmPortSigT399Duration Integer32, stnAtmPortSigSaalRetryDuration Integer32 } stnAtmPortSigDurIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "The interface index represents a connection point on the switch fabric from a module or line card. It is calculated based on the slot and port of the module." ::= { stnAtmPortSigDurationEntry 1 } stnAtmPortSigT301Duration OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "T301 timer. See ITU-T Q.2931 B-ISDN DSS2 User-Network Interface (UNI) Layer 3 Specification for Basic Call/Connection Control" DEFVAL { 180000 } ::= { stnAtmPortSigDurationEntry 2 } stnAtmPortSigT303Duration OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "T303 timer. See ITU-T Q.2931 B-ISDN DSS2 User-Network Interface (UNI) Layer 3 Specification for Basic Call/Connection Control" DEFVAL { 4000 } ::= { stnAtmPortSigDurationEntry 3 } stnAtmPortSigT306Duration OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "T306 timer. See ITU-T Q.2931 B-ISDN DSS2 User-Network Interface (UNI) Layer 3 Specification for Basic Call/Connection Control" DEFVAL { 30000 } ::= { stnAtmPortSigDurationEntry 4 } stnAtmPortSigT308Duration OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "T308 timer. See ITU-T Q.2931 B-ISDN DSS2 User-Network Intrface (UNI) Layer 3 Specification for Basic Call/Connection Control" DEFVAL { 30000 } ::= { stnAtmPortSigDurationEntry 5 } stnAtmPortSigT309Duration OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "T309 timer. See ITU-T Q.2931 B-ISDN DSS2 User-Network Interface (UNI) Layer 3 Specification for Basic Call/Connection Control" DEFVAL { 10000 } ::= { stnAtmPortSigDurationEntry 6 } stnAtmPortSigT310Duration OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "T310 timer. See ITU-T Q.2931 B-ISDN DSS2 User-Network Interface (UNI) Layer 3 Specification for Basic Call/Connection Control" DEFVAL { 10000 } ::= { stnAtmPortSigDurationEntry 7 } stnAtmPortSigT313Duration OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "T313 timer. See ITU-T Q.2931 B-ISDN DSS2 User-Network Interface (UNI) Layer 3 Specification for Basic Call/Connection Control" DEFVAL { 30000 } ::= { stnAtmPortSigDurationEntry 8 } stnAtmPortSigT316Duration OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "T316 timer. See ITU-T Q.2931 B-ISDN DSS2 User-Network Interface (UNI) Layer 3 Specification for Basic Call/Connection Control" DEFVAL { 120000 } ::= { stnAtmPortSigDurationEntry 9 } stnAtmPortSigT317Duration OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "T317 timer. See ITU-T Q.2931 B-ISDN DSS2 User-Network Interface (UNI) Layer 3 Specification for Basic Call/Connection Control" DEFVAL { 60000 } ::= { stnAtmPortSigDurationEntry 10 } stnAtmPortSigT322Duration OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "T322 timer. See ITU-T Q.2931 B-ISDN DSS2 User-Network Interface (UNI) Layer 3 Specification for Basic Call/Connection Control" DEFVAL { 4000 } ::= { stnAtmPortSigDurationEntry 11 } stnAtmPortSigT331Duration OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "T331 timer. See ITU-T Q.2931 B-ISDN DSS2 User-Network Interface (UNI) Layer 3 Specification for Basic Call/Connection Control" DEFVAL { 60000 } ::= { stnAtmPortSigDurationEntry 12 } stnAtmPortSigT333Duration OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "T333 timer. See ITU-T Q.2931 B-ISDN DSS2 User-Network Interface (UNI) Layer 3 Specification for Basic Call/Connection Control" DEFVAL { 10000 } ::= { stnAtmPortSigDurationEntry 13 } stnAtmPortSigT397Duration OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "T397 timer. See ITU-T Q.2931 B-ISDN DSS2 User-Network Interface (UNI) Layer 3 Specification for Basic Call/Connection Control" DEFVAL { 180000 } ::= { stnAtmPortSigDurationEntry 14 } stnAtmPortSigT398Duration OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "T398 timer. See ITU-T Q.2931 B-ISDN DSS2 User-Network Interface (UNI) Layer 3 Specification for Basic Call/Connection Control" DEFVAL { 4000 } ::= { stnAtmPortSigDurationEntry 15 } stnAtmPortSigT399Duration OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "T399 timer. See ITU-T Q.2931 B-ISDN DSS2 User-Network Interface (UNI) Layer 3 Specification for Basic Call/Connection Control" DEFVAL { 14000 } ::= { stnAtmPortSigDurationEntry 16 } stnAtmPortSigSaalRetryDuration OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "SAAL retry duration. See ITU-T Q.2931 B-ISDN DSS2 User-Network Interface (UNI) Layer 3 Specification for Basic Call/Connection Control" DEFVAL { 10000 } ::= { stnAtmPortSigDurationEntry 17 } -- -- STN ATM Port Signaling Timer Retry Table -- -- stnAtmPortSigRetryTable OBJECT-TYPE SYNTAX SEQUENCE OF StnAtmPortSigRetryEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of ATM Port Signaling retry entries." ::= { stnAtmPortSigRetries 1 } stnAtmPortSigRetryEntry OBJECT-TYPE SYNTAX StnAtmPortSigRetryEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry contains information about a ITU-T Q.2931 timer retry counters." INDEX { stnAtmPortSigRetryIfIndex } ::= { stnAtmPortSigRetryTable 1 } StnAtmPortSigRetryEntry ::= SEQUENCE { stnAtmPortSigRetryIfIndex InterfaceIndex, stnAtmPortSigT303Retries Integer32, stnAtmPortSigT308Retries Integer32, stnAtmPortSigT316Retries Integer32, stnAtmPortSigT322Retries Integer32, stnAtmPortSigT331Retries Integer32 } stnAtmPortSigRetryIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "The interface index represents a connection point on the switch fabric from a module or line card. It is calculated based on the slot and port of the module." ::= { stnAtmPortSigRetryEntry 1 } stnAtmPortSigT303Retries OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of ATM Port Signaling T303 retries." DEFVAL { 1 } ::= { stnAtmPortSigRetryEntry 2 } stnAtmPortSigT308Retries OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of ATM Port Signaling T308 retries." DEFVAL { 1 } ::= { stnAtmPortSigRetryEntry 3 } stnAtmPortSigT316Retries OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of ATM Port Signaling T316 retries." DEFVAL { 1 } ::= { stnAtmPortSigRetryEntry 4 } stnAtmPortSigT322Retries OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of ATM Port Signaling T322 retries." DEFVAL { 1 } ::= { stnAtmPortSigRetryEntry 5 } stnAtmPortSigT331Retries OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of ATM Port Signaling T331 retries." DEFVAL { 1 } ::= { stnAtmPortSigRetryEntry 6 } -- -- STN ATM Port Signaling Service Specific Convergence Sublayer (SSCS) -- Table -- stnAtmPortSigSSCSTable OBJECT-TYPE SYNTAX SEQUENCE OF StnAtmPortSigSSCSEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of ATM Port Signaling SSCS entries." ::= { stnAtmPortSigRetries 2 } stnAtmPortSigSSCSEntry OBJECT-TYPE SYNTAX StnAtmPortSigSSCSEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry contains information about a particular Atm Port Signaling SSCS entry." INDEX { stnAtmPortSigSSCSIfIndex } ::= { stnAtmPortSigSSCSTable 1 } StnAtmPortSigSSCSEntry ::= SEQUENCE { stnAtmPortSigSSCSIfIndex InterfaceIndex, stnAtmPortSigSSCSPollDuration Integer32, stnAtmPortSigSSCSKeepAliveDuration Integer32, stnAtmPortSigSSCSIdleDuration Integer32, stnAtmPortSigSSCSNoRspDuration Integer32, stnAtmPortSigSSCSCcDuration Integer32, stnAtmPortSigSSCSMaxRcvWindowSize Integer32, stnAtmPortSigSSCSMaxCcRetries Integer32, stnAtmPortSigSSCSMaxSdBetwPolls Integer32, stnAtmPortSigSSCSMaxStatListElms Integer32, stnAtmPortSigSSCSPollAfterRetrans TruthValue, stnAtmPortSigSSCSRepeatUstat TruthValue, stnAtmPortSigSSCSUstatRspToPoll TruthValue } stnAtmPortSigSSCSIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "The interface index represents a connection point on the switch fabric from a module or line card. It is calculated based on the slot and port of the module." ::= { stnAtmPortSigSSCSEntry 1 } stnAtmPortSigSSCSPollDuration OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The duration of the SSCS Poll timer in milliseconds." DEFVAL { 750 } ::= { stnAtmPortSigSSCSEntry 2 } stnAtmPortSigSSCSKeepAliveDuration OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The duration of the SSCS keep-alive timer in milliseconds." DEFVAL { 2000 } ::= { stnAtmPortSigSSCSEntry 3 } stnAtmPortSigSSCSIdleDuration OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The duration of the SSCS idle timer in milliseconds." DEFVAL { 15000 } ::= { stnAtmPortSigSSCSEntry 4 } stnAtmPortSigSSCSNoRspDuration OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The duration of the SSCS no-response timer in milliseconds." DEFVAL { 7000 } ::= { stnAtmPortSigSSCSEntry 5 } stnAtmPortSigSSCSCcDuration OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The duration of the SSCS CC timer in milliseconds." DEFVAL { 1000 } ::= { stnAtmPortSigSSCSEntry 6 } stnAtmPortSigSSCSMaxRcvWindowSize OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum size on a receive window." DEFVAL { 20 } ::= { stnAtmPortSigSSCSEntry 7 } stnAtmPortSigSSCSMaxCcRetries OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum number of expiries and subsequent connection control PDU retransmissions acceptable before closing the connection." DEFVAL { 4 } ::= { stnAtmPortSigSSCSEntry 8 } stnAtmPortSigSSCSMaxSdBetwPolls OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum number of STAT list elements in a STAT PDU." DEFVAL { 25 } ::= { stnAtmPortSigSSCSEntry 9 } stnAtmPortSigSSCSMaxStatListElms OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum number of STAT list elements in a STAT PDU." DEFVAL { 67 } ::= { stnAtmPortSigSSCSEntry 10 } stnAtmPortSigSSCSPollAfterRetrans OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Whether to send a POLL after retransmitting PDUs." DEFVAL { false } ::= { stnAtmPortSigSSCSEntry 11 } stnAtmPortSigSSCSRepeatUstat OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "QSAAL only: if true, send two USTATs each time a USTAT is sent." DEFVAL { false } ::= { stnAtmPortSigSSCSEntry 12 } stnAtmPortSigSSCSUstatRspToPoll OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "QSAAL only: whether USTAT PDUs are issued in response to POLLs." DEFVAL { false } ::= { stnAtmPortSigSSCSEntry 13 } -- -- STN ATM Port Traffic Table -- stnAtmPortTrafficTable OBJECT-TYPE SYNTAX SEQUENCE OF StnAtmPortTrafficEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of ATM port traffic entries." ::= { stnAtmPortTraffic 1 } stnAtmPortTrafficEntry OBJECT-TYPE SYNTAX StnAtmPortTrafficEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry contains information about a particular ATM port traffic entry." INDEX { stnAtmPortTrafIndex } ::= { stnAtmPortTrafficTable 1 } StnAtmPortTrafficEntry ::= SEQUENCE { stnAtmPortTrafIndex InterfaceIndex, stnAtmPortTrafTxCells Counter32, stnAtmPortTrafRxCells Counter32, stnAtmPortTrafTxParityErrors Counter32, stnAtmPortTrafRxHdrChkSumErrors Counter32, stnAtmPortTrafPhyParityErrors Counter32, stnAtmPortTrafCrc10Errors Counter32 } stnAtmPortTrafIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "The interface index represents a connection point on the switch fabric from a module or line card. It is calculated based on the slot and port of the module." ::= { stnAtmPortTrafficEntry 1 } stnAtmPortTrafTxCells OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of ATM cells transmitted." ::= { stnAtmPortTrafficEntry 2 } stnAtmPortTrafRxCells OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of ATM cells received." ::= { stnAtmPortTrafficEntry 3 } stnAtmPortTrafTxParityErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of ATM transmit parity errors." ::= { stnAtmPortTrafficEntry 4 } stnAtmPortTrafRxHdrChkSumErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of received ATM header checksum errors." ::= { stnAtmPortTrafficEntry 5 } stnAtmPortTrafPhyParityErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of ATM physical parity errors." ::= { stnAtmPortTrafficEntry 6 } stnAtmPortTrafCrc10Errors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of ATM CRC-10 errors." ::= { stnAtmPortTrafficEntry 7 } -- -- STN ATM Address Table -- stnAtmAddressTable OBJECT-TYPE SYNTAX SEQUENCE OF StnAtmAddressEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of ATM address entries." ::= { stnAtmAddresses 1 } stnAtmAddressEntry OBJECT-TYPE SYNTAX StnAtmAddressEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry contains information about a particular session." INDEX { stnAtmAddrIfIndex, stnAtmAddrAddress } ::= { stnAtmAddressTable 1 } StnAtmAddressEntry ::= SEQUENCE { stnAtmAddrIfIndex InterfaceIndex, stnAtmAddrAddress NSAPAddress, stnAtmAddrAddressLen Integer32 } stnAtmAddrIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "The interface index represents a connection point on the switch fabric from a module or line card. It is calculated based on the slot and port of the module." ::= { stnAtmAddressEntry 1 } stnAtmAddrAddress OBJECT-TYPE SYNTAX NSAPAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the ATM NSAP address." ::= { stnAtmAddressEntry 2 } stnAtmAddrAddressLen OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of relevent bits in the ATM address." ::= { stnAtmAddressEntry 3 } -- -- STN ATM Threshold Table -- stnAtmThresholdTable OBJECT-TYPE SYNTAX SEQUENCE OF StnAtmThresholdEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of ATM threshold entries." ::= { stnAtmThresholds 1 } stnAtmThresholdEntry OBJECT-TYPE SYNTAX StnAtmThresholdEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry contains information about a particular ATM threshold entry." INDEX { stnAtmTholdTgrpId, stnAtmTholdRegionId } ::= { stnAtmThresholdTable 1 } StnAtmThresholdEntry ::= SEQUENCE { stnAtmTholdTgrpId INTEGER, stnAtmTholdRegionId INTEGER, stnAtmTholdCellLowerLimit INTEGER, stnAtmTholdCellUpperLimit INTEGER, stnAtmTholdCellQLimitMarking INTEGER, stnAtmTholdQLimitDiscard INTEGER, stnAtmTholdQueueLimit INTEGER } stnAtmTholdTgrpId OBJECT-TYPE SYNTAX INTEGER (0..15) MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies the threshold group indentifier." ::= { stnAtmThresholdEntry 1 } stnAtmTholdRegionId OBJECT-TYPE SYNTAX INTEGER (0..7) MAX-ACCESS read-only STATUS current DESCRIPTION "Region identifier within a threshold group." ::= { stnAtmThresholdEntry 2 } stnAtmTholdCellLowerLimit OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Lower Cell number limit for region." DEFVAL { 0 } ::= { stnAtmThresholdEntry 3 } stnAtmTholdCellUpperLimit OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Upper Cell number limit for region." DEFVAL { 1023 } ::= { stnAtmThresholdEntry 4 } stnAtmTholdCellQLimitMarking OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Queue limit for any flow above which EFCI marking occurs." DEFVAL { 1023 } ::= { stnAtmThresholdEntry 5 } stnAtmTholdQLimitDiscard OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Queue limit for any flow above which Discard processing occurs." DEFVAL { 1023 } ::= { stnAtmThresholdEntry 6 } stnAtmTholdQueueLimit OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Queue limit for any flow above which cells are automatically discarded." DEFVAL { 1023 } ::= { stnAtmThresholdEntry 7 } -- -- STN ATM Accounting Table -- stnAtmAcctEnabled OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies whether account logging is turned on or off." DEFVAL { false } ::= { stnAtmAcct 1 } stnAtmAcctMaxSize OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies the maximum accounting log buffer size. in Kbytes. The accounting log file will be closed when it reaches the maximum size and the name appended with a numeric differentiation." DEFVAL { 1024 } ::= { stnAtmAcct 2 } stnAtmAcctMaxFiles OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies the maximum number of history files to be stored. Once the maximum number of files is reached, the oldest file is deleted." DEFVAL { 10 } ::= { stnAtmAcct 3 } stnAtmAcctFilePath OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies the accounting log output path and file name on remote device." ::= { stnAtmAcct 4 } stnAtmAcctFtpServer1 OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The IP address of the first remote FTP server." ::= { stnAtmAcct 5 } stnAtmAcctFtpUserName1 OBJECT-TYPE SYNTAX DisplayString (SIZE(0..20)) MAX-ACCESS read-only STATUS current DESCRIPTION "The first FTP server username." ::= { stnAtmAcct 6 } stnAtmAcctFtpPassword1 OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The first FTP server password." ::= { stnAtmAcct 7 } stnAtmAcctFtpServer2 OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The IP address of the second remote FTP server." ::= { stnAtmAcct 8 } stnAtmAcctFtpUserName2 OBJECT-TYPE SYNTAX DisplayString (SIZE(0..20)) MAX-ACCESS read-only STATUS current DESCRIPTION "The second FTP server username." ::= { stnAtmAcct 9 } stnAtmAcctFtpPassword2 OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The second FTP server password." ::= { stnAtmAcct 10 } stnAtmAcctFtpServer3 OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The IP address of the third remote FTP server." ::= { stnAtmAcct 11 } stnAtmAcctFtpUserName3 OBJECT-TYPE SYNTAX DisplayString (SIZE(0..20)) MAX-ACCESS read-only STATUS current DESCRIPTION "The third FTP server username." ::= { stnAtmAcct 12 } stnAtmAcctFtpPassword3 OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The third FTP server password." ::= { stnAtmAcct 13 } stnAtmAcctCurrentFtpServer OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The IP address of the current FTP server." ::= { stnAtmAcct 14 } stnAtmAcctPreviousFtpServer OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The IP address of the previous FTP server." ::= { stnAtmAcct 15 } -- -- STN Traps & Notifications -- stnCdrServerFailure NOTIFICATION-TYPE OBJECTS { stnAtmAcctCurrentFtpServer, stnAtmAcctPreviousFtpServer } STATUS current DESCRIPTION "A stnCdrServerFailure trap signifies that the agent entity has detected that the accounting server has failed over to an auxilary server. The generation of this trap can be controlled by the stnNotificationEnableCdrServerFailure object in this MIB." ::= { stnNotification 15 } stnCdrLogFailure NOTIFICATION-TYPE OBJECTS { stnAtmAcctFtpServer1, stnAtmAcctFtpServer2, stnAtmAcctFtpServer3 } STATUS current DESCRIPTION "A stnCdrLogFailure trap signifies that the agent entity has detected that all accounting servers are inaccessible. Accounting data could be lost. The generation of this trap can be controlled by the stnNotificationEnableCdrLogFailure object in this MIB." ::= { stnNotification 16 } stnConfigAuditPvcFailure NOTIFICATION-TYPE OBJECTS { stnVcLinkIfIndex, stnVcLinkVpi, stnVcLinkVci, stnRouterIndex } STATUS current DESCRIPTION "A stnConfigAuditPvcFailure trap signifies that the agent entity has detected an inconsistency between an active and configured PVC after a failover. The generation of this trap can be controlled by the CfgAuditPvcTraps configuration object." ::= { stnNotification 31 } stnConfigAuditSpvcFailure NOTIFICATION-TYPE OBJECTS { stnVcLinkIfIndex, stnVcLinkVpi, stnVcLinkVci, stnRouterIndex } STATUS current DESCRIPTION "A stnConfigAuditSpvcFailure trap signifies that the agent entity has detected an inconsistency between an active and configured SPVC after a failover. The generation of this trap can be controlled by the CfgAuditSpvcTraps configuration object." ::= { stnNotification 32 } END