-- -- This SMIv2 module has been generated by smidump 0.2-cvs. Do not edit. -- SONUS-SS7-SERVICES-MIB DEFINITIONS ::= BEGIN IMPORTS Integer32, IpAddress, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-TYPE FROM SNMPv2-SMI DisplayString, RowStatus, TEXTUAL-CONVENTION FROM SNMPv2-TC sonusEventClass, sonusEventDescription, sonusEventLevel FROM SONUS-COMMON-MIB sonusServicesMIBs FROM SONUS-SMI PointCode, SonusName, SonusPointCode, SonusPointCodeFormat FROM SONUS-TC; sonusSs7ServicesMIB MODULE-IDENTITY LAST-UPDATED "200107310000Z" ORGANIZATION "Sonus Networks, Inc." CONTACT-INFO " Customer Support Sonus Networks, Inc, 5 carlisle Road Westford, MA 01886 USA Tel: 978-692-8999 Fax: 978-392-9118 E-mail: cs.snmp@sonusnet.com" DESCRIPTION "The MIB Module for SS7 Gateway and SS7 Node Configuration." ::= { sonusServicesMIBs 3 } SonusSs7GatewayLinkSelection ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "The SS7 Gateway link selection value." SYNTAX INTEGER { primary(1), secondary(2), none(3), primaryAlt(4), secondaryAlt(5) } sonusSs7ServicesMIBObjects OBJECT IDENTIFIER ::= { sonusSs7ServicesMIB 1 } sonusSs7Gateway OBJECT IDENTIFIER ::= { sonusSs7ServicesMIBObjects 1 } sonusSs7GatewayNextIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The next valid index to use when creating an entry in the sonusSs7GatewayTable." ::= { sonusSs7Gateway 1 } sonusSs7GatewayTable OBJECT-TYPE SYNTAX SEQUENCE OF SonusSs7GatewayEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table specifies the SS7 Gateway list for the GSX9000 node." ::= { sonusSs7Gateway 2 } sonusSs7GatewayEntry OBJECT-TYPE SYNTAX SonusSs7GatewayEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { sonusSs7GatewayIndex } ::= { sonusSs7GatewayTable 1 } SonusSs7GatewayEntry ::= SEQUENCE { sonusSs7GatewayIndex Integer32, sonusSs7GatewayState INTEGER, sonusSs7GatewayName SonusName, sonusSs7GatewaySocketType INTEGER, sonusSs7GatewayActiveHost INTEGER, sonusSs7GatewayPriHostName DisplayString, sonusSs7GatewayPriHostIpaddr IpAddress, sonusSs7GatewayPriHostMode INTEGER, sonusSs7GatewayPriHostOosDelayTimer Integer32, sonusSs7GatewaySecHostName DisplayString, sonusSs7GatewaySecHostIpaddr IpAddress, sonusSs7GatewaySecHostMode INTEGER, sonusSs7GatewaySecHostOosDelayTimer Integer32, sonusSs7GatewayRowStatus RowStatus, sonusSs7GatewayPriAltHostIpaddr IpAddress, sonusSs7GatewaySecAltHostIpaddr IpAddress, sonusSs7GatewayGwType INTEGER, sonusSs7GatewayServerTcpPort Integer32, sonusSs7GatewayClientTcpPort Integer32, sonusSs7GatewayPriTaliTrafficControl INTEGER, sonusSs7GatewayPriAltTaliTrafficControl INTEGER, sonusSs7GatewaySecTaliTrafficControl INTEGER, sonusSs7GatewaySecAltTaliTrafficControl INTEGER, sonusSs7GatewayTimerTaliT1 Integer32, sonusSs7GatewayTimerTaliT2 Integer32, sonusSs7GatewayTimerTaliT3 Integer32, sonusSs7GatewayTimerTaliT4 Integer32, sonusSs7GatewayTaliSs7Type INTEGER, sonusSs7GatewaySlsBits Integer32, sonusSs7GatewayTaliIsupNormalization INTEGER, sonusSs7GatewayTaliPstnPresentation INTEGER, sonusSs7GatewayTaliGroupCode DisplayString } sonusSs7GatewayIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Identifies the target SS7 Gateway entry." ::= { sonusSs7GatewayEntry 1 } sonusSs7GatewayState OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabled(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The administrative state of this SS7 Gateway entry." DEFVAL { disabled } ::= { sonusSs7GatewayEntry 2 } sonusSs7GatewayName OBJECT-TYPE SYNTAX SonusName MAX-ACCESS read-write STATUS current DESCRIPTION "The name of this SS7 Gateway instance." ::= { sonusSs7GatewayEntry 3 } sonusSs7GatewaySocketType OBJECT-TYPE SYNTAX INTEGER { tcp(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the type of socket interface used by the GSX9000 node for connections to the SS7 Gateway platform." DEFVAL { tcp } ::= { sonusSs7GatewayEntry 4 } sonusSs7GatewayActiveHost OBJECT-TYPE SYNTAX INTEGER { primary(1), secondary(2), none(3) } MAX-ACCESS read-only STATUS deprecated DESCRIPTION "This status value has been replaced by sonusSs7GatewayNextHost and sonusSs7GatewaySelectHost." ::= { sonusSs7GatewayEntry 5 } sonusSs7GatewayPriHostName OBJECT-TYPE SYNTAX DisplayString (SIZE(1..39)) MAX-ACCESS read-write STATUS current DESCRIPTION "The host name of the primary link to the SS7 Gateway platform." ::= { sonusSs7GatewayEntry 6 } sonusSs7GatewayPriHostIpaddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies the IP Address of the primary link to the SS7 Gateway platform." ::= { sonusSs7GatewayEntry 7 } sonusSs7GatewayPriHostMode OBJECT-TYPE SYNTAX INTEGER { inService(1), outOfService(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies the service mode of the primary link to the SS7 Gateway platform." DEFVAL { outOfService } ::= { sonusSs7GatewayEntry 8 } sonusSs7GatewayPriHostOosDelayTimer OBJECT-TYPE SYNTAX Integer32 (0..1440) MAX-ACCESS read-write STATUS current DESCRIPTION "This element is used to delay the action of taking the primary host link out of service for a specified number of minutes." DEFVAL { 0 } ::= { sonusSs7GatewayEntry 9 } sonusSs7GatewaySecHostName OBJECT-TYPE SYNTAX DisplayString (SIZE(1..39)) MAX-ACCESS read-write STATUS current DESCRIPTION "The host name of the secondary link to the SS7 Gateway platform." ::= { sonusSs7GatewayEntry 10 } sonusSs7GatewaySecHostIpaddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies the IP Address of the secondary link to the SS7 Gateway platform." ::= { sonusSs7GatewayEntry 11 } sonusSs7GatewaySecHostMode OBJECT-TYPE SYNTAX INTEGER { inService(1), outOfService(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies the service mode of the secondary link to the SS7 Gateway platform." DEFVAL { outOfService } ::= { sonusSs7GatewayEntry 12 } sonusSs7GatewaySecHostOosDelayTimer OBJECT-TYPE SYNTAX Integer32 (0..1440) MAX-ACCESS read-write STATUS current DESCRIPTION "This element is used to delay the action of taking the secondary host link out of service for a specified number of minutes." DEFVAL { 0 } ::= { sonusSs7GatewayEntry 13 } sonusSs7GatewayRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-write STATUS current DESCRIPTION "" ::= { sonusSs7GatewayEntry 14 } sonusSs7GatewayPriAltHostIpaddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies the alternate IP Address of the primary link to the SS7 Gateway platform." ::= { sonusSs7GatewayEntry 15 } sonusSs7GatewaySecAltHostIpaddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies the alternate IP Address of the secondary link to the SS7 Gateway platform." ::= { sonusSs7GatewayEntry 16 } sonusSs7GatewayGwType OBJECT-TYPE SYNTAX INTEGER { tali(1), dgms(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Gateway type is identified by the gateway protocol it uses" DEFVAL { dgms } ::= { sonusSs7GatewayEntry 17 } sonusSs7GatewayServerTcpPort OBJECT-TYPE SYNTAX Integer32 (1024..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "TCP port for the server of TALI connection" ::= { sonusSs7GatewayEntry 18 } sonusSs7GatewayClientTcpPort OBJECT-TYPE SYNTAX Integer32 (1024..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "TCP port for the client of TALI connection" ::= { sonusSs7GatewayEntry 19 } sonusSs7GatewayPriTaliTrafficControl OBJECT-TYPE SYNTAX INTEGER { allow(1), prohibit(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Control the ss7 traffic on the primary TALI connection" DEFVAL { allow } ::= { sonusSs7GatewayEntry 20 } sonusSs7GatewayPriAltTaliTrafficControl OBJECT-TYPE SYNTAX INTEGER { allow(1), prohibit(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Control the ss7 traffic on the primary TALI connection" DEFVAL { allow } ::= { sonusSs7GatewayEntry 21 } sonusSs7GatewaySecTaliTrafficControl OBJECT-TYPE SYNTAX INTEGER { allow(1), prohibit(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Control the ss7 traffic on the secondary TALI connection" DEFVAL { allow } ::= { sonusSs7GatewayEntry 22 } sonusSs7GatewaySecAltTaliTrafficControl OBJECT-TYPE SYNTAX INTEGER { allow(1), prohibit(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Control the ss7 traffic on the secondary TALI connection" DEFVAL { allow } ::= { sonusSs7GatewayEntry 23 } sonusSs7GatewayTimerTaliT1 OBJECT-TYPE SYNTAX Integer32 (100..60000) MAX-ACCESS read-write STATUS current DESCRIPTION "Send a TALI-TEST upon the expiry of T1 in millisecond." DEFVAL { 4000 } ::= { sonusSs7GatewayEntry 24 } sonusSs7GatewayTimerTaliT2 OBJECT-TYPE SYNTAX Integer32 (100..60000) MAX-ACCESS read-write STATUS current DESCRIPTION "Guard timer in millisecond for the return of TALI-ALLO or TALI-PROH in response to a TALI-TEST sent earlier." DEFVAL { 3000 } ::= { sonusSs7GatewayEntry 25 } sonusSs7GatewayTimerTaliT3 OBJECT-TYPE SYNTAX Integer32 (100..60000) MAX-ACCESS read-write STATUS current DESCRIPTION "T3 in millisecond reprsents how long the near end can continue to process received messages after sending TALI-PROH." DEFVAL { 5000 } ::= { sonusSs7GatewayEntry 26 } sonusSs7GatewayTimerTaliT4 OBJECT-TYPE SYNTAX Integer32 (100..60000) MAX-ACCESS read-write STATUS current DESCRIPTION "Send a TALI-MONI upon the expiry of T4 in millisecond." DEFVAL { 10000 } ::= { sonusSs7GatewayEntry 27 } sonusSs7GatewayTaliSs7Type OBJECT-TYPE SYNTAX INTEGER { ansi(1), ituIntl(2), ituNatl(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "SS7 protocol types used over TALI" DEFVAL { ansi } ::= { sonusSs7GatewayEntry 28 } sonusSs7GatewaySlsBits OBJECT-TYPE SYNTAX Integer32 (4..8) MAX-ACCESS read-write STATUS current DESCRIPTION "The number of SLS bits to use" DEFVAL { 5 } ::= { sonusSs7GatewayEntry 29 } sonusSs7GatewayTaliIsupNormalization OBJECT-TYPE SYNTAX INTEGER { norm(1), raw(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "ISUP message format over TALI -- normalized or raw" DEFVAL { norm } ::= { sonusSs7GatewayEntry 30 } sonusSs7GatewayTaliPstnPresentation OBJECT-TYPE SYNTAX INTEGER { q767(1), etsiIsup(2), ukIsup(3), grIsup(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "ISUP types over TALI" DEFVAL { etsiIsup } ::= { sonusSs7GatewayEntry 31 } sonusSs7GatewayTaliGroupCode OBJECT-TYPE SYNTAX DisplayString (SIZE(2)) MAX-ACCESS read-write STATUS current DESCRIPTION "Group Code in ASCII" DEFVAL { "aa" } ::= { sonusSs7GatewayEntry 32 } sonusSs7GatewayStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF SonusSs7GatewayStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Status Table of the SS7 Gateway for the GSX9000 node." ::= { sonusSs7Gateway 3 } sonusSs7GatewayStatusEntry OBJECT-TYPE SYNTAX SonusSs7GatewayStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "List of SS7 Gateway status elements." INDEX { sonusSs7GatewayStatusIndex } ::= { sonusSs7GatewayStatusTable 1 } SonusSs7GatewayStatusEntry ::= SEQUENCE { sonusSs7GatewayStatusIndex Integer32, sonusSs7GatewayNextHost SonusSs7GatewayLinkSelection, sonusSs7GatewaySelectHost SonusSs7GatewayLinkSelection, sonusSs7GatewayPriTaliConnState INTEGER, sonusSs7GatewaySecTaliConnState INTEGER, sonusSs7GatewayPriAltTaliConnState INTEGER, sonusSs7GatewaySecAltTaliConnState INTEGER, sonusSs7GatewayPriNearEndTaliVersion DisplayString, sonusSs7GatewayPriFarEndTaliVersion DisplayString, sonusSs7GatewayPriAltNearEndTaliVersion DisplayString, sonusSs7GatewayPriAltFarEndTaliVersion DisplayString, sonusSs7GatewaySecNearEndTaliVersion DisplayString, sonusSs7GatewaySecFarEndTaliVersion DisplayString, sonusSs7GatewaySecAltNearEndTaliVersion DisplayString, sonusSs7GatewaySecAltFarEndTaliVersion DisplayString } sonusSs7GatewayStatusIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Identifies the SS7 Gateway status entry." ::= { sonusSs7GatewayStatusEntry 1 } sonusSs7GatewayNextHost OBJECT-TYPE SYNTAX SonusSs7GatewayLinkSelection MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates which host link connection to the SS7 Gateway is next to be selected. If there is none, then this element is set to none." DEFVAL { none } ::= { sonusSs7GatewayStatusEntry 2 } sonusSs7GatewaySelectHost OBJECT-TYPE SYNTAX SonusSs7GatewayLinkSelection MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates which host link connection to the SS7 Gateway is selected to be tried. If there is none, then this element is set to none." DEFVAL { none } ::= { sonusSs7GatewayStatusEntry 3 } sonusSs7GatewayPriTaliConnState OBJECT-TYPE SYNTAX INTEGER { oos(1), connecting(2), nepFep(3), nepFea(4), neaFep(5), neaFea(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "TALI state of the primary connection for this SS7 gateway." DEFVAL { oos } ::= { sonusSs7GatewayStatusEntry 4 } sonusSs7GatewaySecTaliConnState OBJECT-TYPE SYNTAX INTEGER { oos(1), connecting(2), nepFep(3), nepFea(4), neaFep(5), neaFea(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "TALI state of the secondary connection for this SS7 gateway." DEFVAL { oos } ::= { sonusSs7GatewayStatusEntry 5 } sonusSs7GatewayPriAltTaliConnState OBJECT-TYPE SYNTAX INTEGER { oos(1), connecting(2), nepFep(3), nepFea(4), neaFep(5), neaFea(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "TALI state of the primary alt connection for this SS7 gateway." DEFVAL { oos } ::= { sonusSs7GatewayStatusEntry 6 } sonusSs7GatewaySecAltTaliConnState OBJECT-TYPE SYNTAX INTEGER { oos(1), connecting(2), nepFep(3), nepFea(4), neaFep(5), neaFea(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "TALI state of the secondary alt connection for this SS7 gateway." DEFVAL { oos } ::= { sonusSs7GatewayStatusEntry 7 } sonusSs7GatewayPriNearEndTaliVersion OBJECT-TYPE SYNTAX DisplayString (SIZE(7)) MAX-ACCESS read-only STATUS current DESCRIPTION "TALI protocol version at the near end of the pri conncection" DEFVAL { "001.000" } ::= { sonusSs7GatewayStatusEntry 8 } sonusSs7GatewayPriFarEndTaliVersion OBJECT-TYPE SYNTAX DisplayString (SIZE(7)) MAX-ACCESS read-only STATUS current DESCRIPTION "TALI protocol version at the far end of the pri connection" DEFVAL { "001.000" } ::= { sonusSs7GatewayStatusEntry 9 } sonusSs7GatewayPriAltNearEndTaliVersion OBJECT-TYPE SYNTAX DisplayString (SIZE(7)) MAX-ACCESS read-only STATUS current DESCRIPTION "TALI protocol version at the near end of the pri-alt conn." DEFVAL { "001.000" } ::= { sonusSs7GatewayStatusEntry 10 } sonusSs7GatewayPriAltFarEndTaliVersion OBJECT-TYPE SYNTAX DisplayString (SIZE(7)) MAX-ACCESS read-only STATUS current DESCRIPTION "TALI protocol version at the far end of the pri-alt connection" DEFVAL { "001.000" } ::= { sonusSs7GatewayStatusEntry 11 } sonusSs7GatewaySecNearEndTaliVersion OBJECT-TYPE SYNTAX DisplayString (SIZE(7)) MAX-ACCESS read-only STATUS current DESCRIPTION "TALI protocol version at the near end of the sec conncection" DEFVAL { "001.000" } ::= { sonusSs7GatewayStatusEntry 12 } sonusSs7GatewaySecFarEndTaliVersion OBJECT-TYPE SYNTAX DisplayString (SIZE(7)) MAX-ACCESS read-only STATUS current DESCRIPTION "TALI protocol version at the far end of the sec connection" DEFVAL { "001.000" } ::= { sonusSs7GatewayStatusEntry 13 } sonusSs7GatewaySecAltNearEndTaliVersion OBJECT-TYPE SYNTAX DisplayString (SIZE(7)) MAX-ACCESS read-only STATUS current DESCRIPTION "TALI protocol version at the near end of the sec-alt conn." DEFVAL { "001.000" } ::= { sonusSs7GatewayStatusEntry 14 } sonusSs7GatewaySecAltFarEndTaliVersion OBJECT-TYPE SYNTAX DisplayString (SIZE(7)) MAX-ACCESS read-only STATUS current DESCRIPTION "TALI protocol version at the far end of the sec-alt connection" DEFVAL { "001.000" } ::= { sonusSs7GatewayStatusEntry 15 } sonusSs7GatewayPSStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF SonusSs7GatewayPSStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Status Table of the SS7 Gateway of a PRIMARY or SECONDARY for the GSX9000 node." ::= { sonusSs7Gateway 4 } sonusSs7GatewayPSStatusEntry OBJECT-TYPE SYNTAX SonusSs7GatewayPSStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "List of SS7 Gateway status elements." INDEX { sonusSs7GatewayPSStatusIndex, sonusSs7GatewayPSStatusPSIndex } ::= { sonusSs7GatewayPSStatusTable 1 } SonusSs7GatewayPSStatusEntry ::= SEQUENCE { sonusSs7GatewayPSStatusIndex Integer32, sonusSs7GatewayPSStatusPSIndex INTEGER, sonusSs7GatewayPSStatusPrimaryCE Integer32, sonusSs7GatewayPSStatusActiveLink Integer32 } sonusSs7GatewayPSStatusIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Identifies the SS7 Gateway status entry." ::= { sonusSs7GatewayPSStatusEntry 1 } sonusSs7GatewayPSStatusPSIndex OBJECT-TYPE SYNTAX INTEGER { primary(0), secondary(1), primaryAlt(2), secondaryAlt(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Identifies the SS7 Gateway link status entry." ::= { sonusSs7GatewayPSStatusEntry 2 } sonusSs7GatewayPSStatusPrimaryCE OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Identifies the link Primary CE value." ::= { sonusSs7GatewayPSStatusEntry 3 } sonusSs7GatewayPSStatusActiveLink OBJECT-TYPE SYNTAX Integer32 (0..16) MAX-ACCESS read-only STATUS current DESCRIPTION "Identifies the link active entry." ::= { sonusSs7GatewayPSStatusEntry 4 } sonusSs7GatewayLinkStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF SonusSs7GatewayLinkStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Link Status Table of a SS7 Gateway for the GSX9000 node." ::= { sonusSs7Gateway 5 } sonusSs7GatewayLinkStatusEntry OBJECT-TYPE SYNTAX SonusSs7GatewayLinkStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "List of SS7 Gateway Link Status elements." INDEX { sonusSs7GatewayStatusLinkIndex, sonusSs7GatewayStatusLinkPSIndex, sonusSs7GatewayStatusLinkHostIndex } ::= { sonusSs7GatewayLinkStatusTable 1 } SonusSs7GatewayLinkStatusEntry ::= SEQUENCE { sonusSs7GatewayStatusLinkIndex Integer32, sonusSs7GatewayStatusLinkPSIndex INTEGER, sonusSs7GatewayStatusLinkHostIndex Integer32, sonusSs7GatewayStatusHostName DisplayString, sonusSs7GatewayStatusHostIpaddr IpAddress, sonusSs7GatewayStatusHostState INTEGER, sonusSs7GatewayStatusHostCE Integer32 } sonusSs7GatewayStatusLinkIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Identifies the SS7 Gateway status link entry gateway index." ::= { sonusSs7GatewayLinkStatusEntry 1 } sonusSs7GatewayStatusLinkPSIndex OBJECT-TYPE SYNTAX INTEGER { primary(1), secondary(2), primaryAlt(3), secondaryAlt(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "Identifies the SS7 Gateway status link entry primary or secondary index." ::= { sonusSs7GatewayLinkStatusEntry 2 } sonusSs7GatewayStatusLinkHostIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Identifies the SS7 Gateway host status link entry index." ::= { sonusSs7GatewayLinkStatusEntry 3 } sonusSs7GatewayStatusHostName OBJECT-TYPE SYNTAX DisplayString (SIZE(1..39)) MAX-ACCESS read-only STATUS current DESCRIPTION "The host name of the Link link to the SS7 Gateway platform." ::= { sonusSs7GatewayLinkStatusEntry 4 } sonusSs7GatewayStatusHostIpaddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies the IP Address of the link to the SS7 Gateway platform." ::= { sonusSs7GatewayLinkStatusEntry 5 } sonusSs7GatewayStatusHostState OBJECT-TYPE SYNTAX INTEGER { empty(1), init(2), available(3), broken(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "The state of host link to the SS7 Gateway platform." ::= { sonusSs7GatewayLinkStatusEntry 6 } sonusSs7GatewayStatusHostCE OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The CE of host link to the SS7 Gateway platform." ::= { sonusSs7GatewayLinkStatusEntry 7 } sonusSs7NodeStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF SonusSs7NodeStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Status Table of the SS7 Node for the GSX9000 node." ::= { sonusSs7Gateway 6 } sonusSs7NodeStatusEntry OBJECT-TYPE SYNTAX SonusSs7NodeStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "List of SS7 Node status elements." INDEX { sonusSs7NodeStatusIndex } ::= { sonusSs7NodeStatusTable 1 } SonusSs7NodeStatusEntry ::= SEQUENCE { sonusSs7NodeStatusIndex Integer32, sonusSs7NodeStatIsup INTEGER, sonusSs7NodeStatMtp INTEGER } sonusSs7NodeStatusIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Identifies the SS7 Node status entry." ::= { sonusSs7NodeStatusEntry 1 } sonusSs7NodeStatIsup OBJECT-TYPE SYNTAX INTEGER { offline(1), active(2), initializing(3), failed(4), disabled(5), congested(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies the operating status of the ISUP service within this SS7 Node." DEFVAL { offline } ::= { sonusSs7NodeStatusEntry 2 } sonusSs7NodeStatMtp OBJECT-TYPE SYNTAX INTEGER { paused(1), resumed(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies the current MTP status for this SS7 Node." DEFVAL { paused } ::= { sonusSs7NodeStatusEntry 3 } sonusSs7Node OBJECT IDENTIFIER ::= { sonusSs7ServicesMIBObjects 2 } sonusSs7NodeNextIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The next valid index to use when creating an entry in the sonusSs7NodeTable." ::= { sonusSs7Node 1 } sonusSs7NodeTable OBJECT-TYPE SYNTAX SEQUENCE OF SonusSs7NodeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table specifies the SS7 Node list for the GSX9000 node." ::= { sonusSs7Node 2 } sonusSs7NodeEntry OBJECT-TYPE SYNTAX SonusSs7NodeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { sonusSs7NodeIndex } ::= { sonusSs7NodeTable 1 } SonusSs7NodeEntry ::= SEQUENCE { sonusSs7NodeIndex Integer32, sonusSs7NodeState INTEGER, sonusSs7NodeName SonusName, sonusSs7NodePointCode PointCode, sonusSs7NodeServices INTEGER, sonusSs7NodeProtocol INTEGER, sonusSs7NodeTcapSsn Integer32, sonusSs7NodeIsupStatus INTEGER, sonusSs7NodeTcapStatus INTEGER, sonusSs7NodeMtpStatus INTEGER, sonusSs7NodeGatewayAssignment DisplayString, sonusSs7NodeNativePointCode Integer32, sonusSs7NodeMode INTEGER, sonusSs7NodeConnCntrl INTEGER, sonusSs7NodeRowStatus RowStatus, sonusSs7NodeStdPointCode SonusPointCode, sonusSs7NodePointCodeSize Integer32, sonusSs7NodePointCodeFormatType SonusPointCodeFormat, sonusSs7NodeServerProtocol INTEGER, sonusSs7NodeHandShakeInterval Integer32, sonusSs7NodeTimerT1 Integer32, sonusSs7NodeTimerT2 Integer32, sonusSs7NodeTimerT3 Integer32, sonusSs7NodeTimerT4 Integer32, sonusSs7NodeTimerT5 Integer32, sonusSs7NodeTimerT6 Integer32, sonusSs7NodeTimerT7 Integer32, sonusSs7NodeTimerT8 Integer32, sonusSs7NodeTimerT9 Integer32, sonusSs7NodeTimerT10 Integer32, sonusSs7NodeTimerT11 Integer32, sonusSs7NodeTimerT12 Integer32, sonusSs7NodeTimerT13 Integer32, sonusSs7NodeTimerT14 Integer32, sonusSs7NodeTimerT15 Integer32, sonusSs7NodeTimerT16 Integer32, sonusSs7NodeTimerT17 Integer32, sonusSs7NodeTimerT18 Integer32, sonusSs7NodeTimerT19 Integer32, sonusSs7NodeTimerT20 Integer32, sonusSs7NodeTimerT21 Integer32, sonusSs7NodeTimerT22 Integer32, sonusSs7NodeTimerT23 Integer32, sonusSs7NodeTimerT24 Integer32, sonusSs7NodeTimerT25 Integer32, sonusSs7NodeTimerT26 Integer32, sonusSs7NodeTimerT27 Integer32, sonusSs7NodeTimerT28 Integer32, sonusSs7NodeTimerT29 Integer32, sonusSs7NodeTimerT30 Integer32, sonusSs7NodeTimerT31 Integer32, sonusSs7NodeTimerT32 Integer32, sonusSs7NodeTimerT33 Integer32, sonusSs7NodeTimerT34 Integer32, sonusSs7NodeTimerT35 Integer32, sonusSs7NodeTimerT36 Integer32, sonusSs7NodeTimerT37 Integer32, sonusSs7NodeTimerT38 Integer32, sonusSs7NodeTimerT39 Integer32, sonusSs7NodeTimerT40 Integer32, sonusSs7NodeTimerTAcc Integer32, sonusSs7NodeTimerTCcr Integer32, sonusSs7NodeTimerTCcrr Integer32, sonusSs7NodeTimerTCgb Integer32, sonusSs7NodeTimerTCra Integer32, sonusSs7NodeTimerTCrm Integer32, sonusSs7NodeTimerTCvt Integer32, sonusSs7NodeTimerTExm Integer32, sonusSs7NodeTimerTGrs Integer32, sonusSs7NodeTimerTHga Integer32, sonusSs7NodeTimerTScga Integer32, sonusSs7NodeTimerTScgad Integer32, sonusSs7NodeApplProfileName DisplayString, sonusSs7NodeNetworkInd INTEGER, sonusSs7NodeSlsBits Integer32, sonusSs7NodeTimerTA Integer32, sonusSs7NodeTimerTBlom Integer32, sonusSs7NodeTimerTCotd Integer32, sonusSs7NodeTimerTCotl Integer32, sonusSs7NodeTimerTSus Integer32 } sonusSs7NodeIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Identifies the target SS7 Node entry." ::= { sonusSs7NodeEntry 1 } sonusSs7NodeState OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabled(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The administrative state of this SS7 Node entry." DEFVAL { disabled } ::= { sonusSs7NodeEntry 2 } sonusSs7NodeName OBJECT-TYPE SYNTAX SonusName MAX-ACCESS read-write STATUS current DESCRIPTION "The name of this SS7 Node instance." ::= { sonusSs7NodeEntry 3 } sonusSs7NodePointCode OBJECT-TYPE SYNTAX PointCode MAX-ACCESS read-write STATUS current DESCRIPTION "The SS7 point code assigned to this SS7 Node entry." ::= { sonusSs7NodeEntry 4 } sonusSs7NodeServices OBJECT-TYPE SYNTAX INTEGER { isupOnly(1), tcapOnly(2), isupAndTcap(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The type of SS7 services (ISUP, TCAP, or both) supported by this SS7 Node entry. As of GSX release 3.02.00, isupOnly is now the only vaild option for this entry." DEFVAL { isupOnly } ::= { sonusSs7NodeEntry 5 } sonusSs7NodeProtocol OBJECT-TYPE SYNTAX INTEGER { ansi(1), itu(2), etsi(3), japan(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "The SS7 protocol type supported by this SS7 Node entry." DEFVAL { ansi } ::= { sonusSs7NodeEntry 6 } sonusSs7NodeTcapSsn OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS obsolete DESCRIPTION "If Tcap is supported by this SS7 Node, specifies the Sub System Number for this node entry. This object is obsoleted as of GSX release 3.02.00." DEFVAL { 0 } ::= { sonusSs7NodeEntry 7 } sonusSs7NodeIsupStatus OBJECT-TYPE SYNTAX INTEGER { offline(1), active(2), initializing(3), failed(4), disabled(5), congested(6) } MAX-ACCESS read-only STATUS deprecated DESCRIPTION "This status value has been replaced by sonusSs7NodeStatIsup" ::= { sonusSs7NodeEntry 8 } sonusSs7NodeTcapStatus OBJECT-TYPE SYNTAX INTEGER { offline(1), active(2), initializing(3), failed(4), disabled(5), congested(6) } MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Specifies the operating status of the TCAP service within this SS7 Node. This object is obsoleted as of GSX release 3.02.00." DEFVAL { offline } ::= { sonusSs7NodeEntry 9 } sonusSs7NodeMtpStatus OBJECT-TYPE SYNTAX INTEGER { paused(1), resumed(2) } MAX-ACCESS read-only STATUS deprecated DESCRIPTION "This status value has been replaced by sonusSs7NodeStatMtp" ::= { sonusSs7NodeEntry 10 } sonusSs7NodeGatewayAssignment OBJECT-TYPE SYNTAX DisplayString (SIZE(1..23)) MAX-ACCESS read-write STATUS current DESCRIPTION "The name of the SS7 Gateway to which this SS7 Node is assigned." ::= { sonusSs7NodeEntry 11 } sonusSs7NodeNativePointCode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The native point code of the SS7 node. e.g. For ITU the point code is in 3 bit 8 bit 3 bit format adding up to 14 bits whereas ANSI uses a 8bit 8bit 8bit format adding up to 24 bits." DEFVAL { 0 } ::= { sonusSs7NodeEntry 12 } sonusSs7NodeMode OBJECT-TYPE SYNTAX INTEGER { inService(1), outOfService(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies the service mode for this SS7 Node." DEFVAL { outOfService } ::= { sonusSs7NodeEntry 13 } sonusSs7NodeConnCntrl OBJECT-TYPE SYNTAX INTEGER { always(1), asNeeded(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies when the Node will establish an ISUP connection with the SS7 Gateway. This parameter is used to minimize unnecessary connections to the SS7 Gateway for ISUP services, allowing the GSX to only establish the ISUP connections that are required by ISUP circuits on a particular shelf. When set to always, the ISUP service connection will be established when the node is enabled. When set to asNeeded, the ISUP service connection will be established only if there are ISUP circuits assigned to this node. This parameter only applies to ISUP service registration." DEFVAL { asNeeded } ::= { sonusSs7NodeEntry 14 } sonusSs7NodeRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-write STATUS current DESCRIPTION "" ::= { sonusSs7NodeEntry 15 } sonusSs7NodeStdPointCode OBJECT-TYPE SYNTAX SonusPointCode MAX-ACCESS read-write STATUS current DESCRIPTION "Octet string of the point code. This gives the actual representation the user entered." ::= { sonusSs7NodeEntry 16 } sonusSs7NodePointCodeSize OBJECT-TYPE SYNTAX Integer32 (1..32) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the total number of bits in the point code." DEFVAL { 24 } ::= { sonusSs7NodeEntry 17 } sonusSs7NodePointCodeFormatType OBJECT-TYPE SYNTAX SonusPointCodeFormat MAX-ACCESS read-write STATUS current DESCRIPTION "The Point Code format type being defined." ::= { sonusSs7NodeEntry 18 } sonusSs7NodeServerProtocol OBJECT-TYPE SYNTAX INTEGER { dgmsProp(1), dgmsRaw(2), tekTali(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The interface used between the SS7 gateway and the SS7 client on the GSX9000" DEFVAL { dgmsProp } ::= { sonusSs7NodeEntry 19 } sonusSs7NodeHandShakeInterval OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-write STATUS current DESCRIPTION "HandShake interval between the client and the server in seconds." ::= { sonusSs7NodeEntry 20 } sonusSs7NodeTimerT1 OBJECT-TYPE SYNTAX Integer32 (4..60) MAX-ACCESS read-write STATUS current DESCRIPTION "The Timer T1 could be changed from its default using this entry. The valid ranges are 4 - 15 seconds for ANSI and 15 - 60 Seconds for ITU." DEFVAL { 10 } ::= { sonusSs7NodeEntry 21 } sonusSs7NodeTimerT2 OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-write STATUS current DESCRIPTION "The Timer T2 could be changed from its default using this entry. The valid value for ITU is 3 Minutes. This timer has no relevence in the ANSI network. " DEFVAL { 180 } ::= { sonusSs7NodeEntry 22 } sonusSs7NodeTimerT3 OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-write STATUS current DESCRIPTION "The T3 timer is started on receipt of an Overload message in the ITU network. This has no relevence in the ANSI network. The valid ITU recommended value is 120 Seconds " DEFVAL { 120 } ::= { sonusSs7NodeEntry 23 } sonusSs7NodeTimerT4 OBJECT-TYPE SYNTAX Integer32 (300..900) MAX-ACCESS read-write STATUS current DESCRIPTION "The Timer T4 could be changed from its default using this entry." DEFVAL { 600 } ::= { sonusSs7NodeEntry 24 } sonusSs7NodeTimerT5 OBJECT-TYPE SYNTAX Integer32 (60..900) MAX-ACCESS read-write STATUS current DESCRIPTION "The T5 Timer is started when the release message is sent. The valid values as per the specifications are 60 seconds for the ANSI and 300 to 900 seconds for ITU." DEFVAL { 60 } ::= { sonusSs7NodeEntry 25 } sonusSs7NodeTimerT6 OBJECT-TYPE SYNTAX Integer32 (1..120) MAX-ACCESS read-write STATUS current DESCRIPTION "The timer T6 is started when the suspend message is received. The valid range for this timer is 1 to 120 seconds." DEFVAL { 22 } ::= { sonusSs7NodeEntry 26 } sonusSs7NodeTimerT7 OBJECT-TYPE SYNTAX Integer32 (20..30) MAX-ACCESS read-write STATUS current DESCRIPTION "The Timer T7 could be changed from its default using this entry." DEFVAL { 25 } ::= { sonusSs7NodeEntry 27 } sonusSs7NodeTimerT8 OBJECT-TYPE SYNTAX Integer32 (10..15) MAX-ACCESS read-write STATUS current DESCRIPTION "The T8 timer is timer to be started with continuity check has been indicated in the IAM. The valid range is 10 to 15 seconds." DEFVAL { 13 } ::= { sonusSs7NodeEntry 28 } sonusSs7NodeTimerT9 OBJECT-TYPE SYNTAX Integer32 (120..240) MAX-ACCESS read-write STATUS current DESCRIPTION "The Timer T9 started when outgoing international exchange recieves an ACM. The valid range is 120 to 240 seconds." DEFVAL { 180 } ::= { sonusSs7NodeEntry 29 } sonusSs7NodeTimerT10 OBJECT-TYPE SYNTAX Integer32 (4..6) MAX-ACCESS read-write STATUS current DESCRIPTION "The Timer T10 is started when the last digit is recived in interworking situations. This timer has no relevence to ANSI." ::= { sonusSs7NodeEntry 30 } sonusSs7NodeTimerT11 OBJECT-TYPE SYNTAX Integer32 (15..20) MAX-ACCESS read-write STATUS current DESCRIPTION "The Timer T11 is started when the latest address message is received in interworking situations. The valid range is 15 to 20 seconds." DEFVAL { 17 } ::= { sonusSs7NodeEntry 31 } sonusSs7NodeTimerT12 OBJECT-TYPE SYNTAX Integer32 (4..60) MAX-ACCESS read-write STATUS current DESCRIPTION "The Timer T12 is started when a blocking message is sent. The valid ranges are 4 to 15 seconds for ANSI and 15 to 60 seconds for ITU." DEFVAL { 10 } ::= { sonusSs7NodeEntry 32 } sonusSs7NodeTimerT13 OBJECT-TYPE SYNTAX Integer32 (60..900) MAX-ACCESS read-write STATUS current DESCRIPTION "The Timer T13 is started when the initial blocking messge is sent. The valid value for ANSI is 60 seconds and for ITU is between 300 and 900 seconds." DEFVAL { 60 } ::= { sonusSs7NodeEntry 33 } sonusSs7NodeTimerT14 OBJECT-TYPE SYNTAX Integer32 (4..60) MAX-ACCESS read-write STATUS current DESCRIPTION "The Timer T14 is started when an unblocking message is sent. The valid values are 4 to 15 seconds for ANSI and 15 to 60 seconds for ITU" DEFVAL { 10 } ::= { sonusSs7NodeEntry 34 } sonusSs7NodeTimerT15 OBJECT-TYPE SYNTAX Integer32 (60..900) MAX-ACCESS read-write STATUS current DESCRIPTION "The Timer T15 is started when the initial unblocking message is sent. The valid values are 60 seconds for ANSI and 300 to 900 seconds for ITU." DEFVAL { 60 } ::= { sonusSs7NodeEntry 35 } sonusSs7NodeTimerT16 OBJECT-TYPE SYNTAX Integer32 (4..60) MAX-ACCESS read-write STATUS current DESCRIPTION "The Timer T16 is started when the reset circuit is started which was not due to expiry of T5. The valid ranges are 4 to 15 seconds for ANSI and 15 to 60 seconds for ITU." DEFVAL { 10 } ::= { sonusSs7NodeEntry 36 } sonusSs7NodeTimerT17 OBJECT-TYPE SYNTAX Integer32 (60..900) MAX-ACCESS read-write STATUS current DESCRIPTION "The Timer T17 is started when initial reset message is sent. The valid values are 60 seconds for ANSI and 300 to 900 for ITU." DEFVAL { 60 } ::= { sonusSs7NodeEntry 37 } sonusSs7NodeTimerT18 OBJECT-TYPE SYNTAX Integer32 (4..60) MAX-ACCESS read-write STATUS current DESCRIPTION "The Timer T18 is started when circuit group blocking message is sent. The valid values are 4 to 15 seconds for ANSI and 15 to 60 seconds for ITU." DEFVAL { 10 } ::= { sonusSs7NodeEntry 38 } sonusSs7NodeTimerT19 OBJECT-TYPE SYNTAX Integer32 (60..900) MAX-ACCESS read-write STATUS current DESCRIPTION "The Timer T19 is started when initial group blocking message is sent. The valid values are 60 seconds for ANSI and 300 to 900 seconds for ITU." DEFVAL { 60 } ::= { sonusSs7NodeEntry 39 } sonusSs7NodeTimerT20 OBJECT-TYPE SYNTAX Integer32 (4..60) MAX-ACCESS read-write STATUS current DESCRIPTION "The Timer T20 is started when group unblocking message is sent. The valid ranges are 4 to 15 seconds for ANSI and 15 to 60 seconds for ITU." DEFVAL { 10 } ::= { sonusSs7NodeEntry 40 } sonusSs7NodeTimerT21 OBJECT-TYPE SYNTAX Integer32 (60..900) MAX-ACCESS read-write STATUS current DESCRIPTION "The Timer T21 is started when initial group blocking message is sent. The valid values are 60 seconds for ANSI and 300 to 900 seconds for ITU." DEFVAL { 60 } ::= { sonusSs7NodeEntry 41 } sonusSs7NodeTimerT22 OBJECT-TYPE SYNTAX Integer32 (4..60) MAX-ACCESS read-write STATUS current DESCRIPTION "The Timer T22 is started when circuit group reset message is sent. The valid values are 4 to 15 seconds for ANSI and 15 to 60 seconds for ITU." DEFVAL { 10 } ::= { sonusSs7NodeEntry 42 } sonusSs7NodeTimerT23 OBJECT-TYPE SYNTAX Integer32 (60..900) MAX-ACCESS read-write STATUS current DESCRIPTION "The Timer T23 is started when initial group reset message is sent. The valid values are 60 seconds for the ANSI and 300 to 900 seconds for the ITU." DEFVAL { 60 } ::= { sonusSs7NodeEntry 43 } sonusSs7NodeTimerT24 OBJECT-TYPE SYNTAX Integer32 (1..2) MAX-ACCESS read-write STATUS current DESCRIPTION "The Timer T24 is started when check tone is sent. The value is less than 2 seconds." DEFVAL { 1 } ::= { sonusSs7NodeEntry 44 } sonusSs7NodeTimerT25 OBJECT-TYPE SYNTAX Integer32 (1..10) MAX-ACCESS read-write STATUS current DESCRIPTION "The Timer T25 is started when initial continuity check failure is detected. The range is 1 to 10 seconds." DEFVAL { 5 } ::= { sonusSs7NodeEntry 45 } sonusSs7NodeTimerT26 OBJECT-TYPE SYNTAX Integer32 (60..180) MAX-ACCESS read-write STATUS current DESCRIPTION "The Timer T26 is started when a second or subsequent continuity failure is detected. The valid value are 60 to 180 seconds." DEFVAL { 120 } ::= { sonusSs7NodeEntry 46 } sonusSs7NodeTimerT27 OBJECT-TYPE SYNTAX Integer32 (180..36000) MAX-ACCESS read-write STATUS current DESCRIPTION "The Timer T27 is started when a continuity fail message is recieved. The valid values are more than 180 seconds for ANSI and 240 seconds for ITU. " DEFVAL { 240 } ::= { sonusSs7NodeEntry 47 } sonusSs7NodeTimerT28 OBJECT-TYPE SYNTAX Integer32 (5..12) MAX-ACCESS read-write STATUS current DESCRIPTION "The Timer T28 is started when Circuit Query Message is sent. The valid value is 10 seconds." DEFVAL { 10 } ::= { sonusSs7NodeEntry 48 } sonusSs7NodeTimerT29 OBJECT-TYPE SYNTAX Integer32 (300..600) MAX-ACCESS read-write STATUS current DESCRIPTION "The Timer T29 is started when Congestion indication is received when T29 is not running. The valid range is 300 to 600 milli second. This timer has no relevence for ANSI." ::= { sonusSs7NodeEntry 49 } sonusSs7NodeTimerT30 OBJECT-TYPE SYNTAX Integer32 (5..10) MAX-ACCESS read-write STATUS current DESCRIPTION "The Timer T30 is stared when congestion indication is recieved when T29 is not running. The valid range is 5 to 10 seconds for the ITU. This timer has no relevence under ANSI." ::= { sonusSs7NodeEntry 50 } sonusSs7NodeTimerT31 OBJECT-TYPE SYNTAX Integer32 (360..65520) MAX-ACCESS read-write STATUS current DESCRIPTION "The Timer T31 is started on release of ISUP signalling connection based on CO SCCP. The value should be set to greater than 360 seconds" DEFVAL { 420 } ::= { sonusSs7NodeEntry 51 } sonusSs7NodeTimerT32 OBJECT-TYPE SYNTAX Integer32 (3..5) MAX-ACCESS read-write STATUS current DESCRIPTION "The Timer T32 is started when the first end-to-end message is recived. Under ANSI this timer is started after the response to such a message is sent. The valid values are 3 to 5 seconds. " DEFVAL { 4 } ::= { sonusSs7NodeEntry 52 } sonusSs7NodeTimerT33 OBJECT-TYPE SYNTAX Integer32 (12..15) MAX-ACCESS read-write STATUS current DESCRIPTION "The Timer T33 is started when Information Request Message is sent. The valid range is 12 to 15 seconds." DEFVAL { 14 } ::= { sonusSs7NodeEntry 53 } sonusSs7NodeTimerT34 OBJECT-TYPE SYNTAX Integer32 (2..15) MAX-ACCESS read-write STATUS current DESCRIPTION "The Timer T34 is started when Loop Back Acknowledgement is sent under ANSI. The Timer T34 is started when segmentation is received for IAM, ACM, CPG, ANM or CON under ITU. The valid range for ANSI is 10 to 15 seconds. The valid range for ITU is 2 to 4 seconds." ::= { sonusSs7NodeEntry 54 } sonusSs7NodeTimerT35 OBJECT-TYPE SYNTAX Integer32 (15..20) MAX-ACCESS read-write STATUS current DESCRIPTION "The Timer T35 is started when the last digit recieved is not an ST digit or the fixed number of digits have been recieved. This procedure is only valid for overlap hence ITU. This timer has no relevence in ANSI." DEFVAL { 18 } ::= { sonusSs7NodeEntry 55 } sonusSs7NodeTimerT36 OBJECT-TYPE SYNTAX Integer32 (2..15) MAX-ACCESS read-write STATUS current DESCRIPTION "The Timer T36 is started when IAM is recived with a segmentation indication for ANSI. This timer is started when transit or incoming international exchange recieves Continuity check request message. The valid range for ANSI is 2 to 4 seconds and 10 to 15 seconds for ITU. " ::= { sonusSs7NodeEntry 56 } sonusSs7NodeTimerT37 OBJECT-TYPE SYNTAX Integer32 (2..30) MAX-ACCESS read-write STATUS current DESCRIPTION "The Timer T37 is started when User Part Availability test is started under ANSI. This timer is started when a request for and Echo control device is sent to another exchange under ITU. The valid value for ANSI is 30 seconds and for ITU is 2 to 4 seconds." ::= { sonusSs7NodeEntry 57 } sonusSs7NodeTimerT38 OBJECT-TYPE SYNTAX Integer32 (10..60) MAX-ACCESS read-write STATUS current DESCRIPTION "The Timer T38 is started when a suspend message is sent to the preceding switch. This timer is only relevent under ITU." DEFVAL { 30 } ::= { sonusSs7NodeEntry 58 } sonusSs7NodeTimerT39 OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "The Timer T39 is started when MCID request is sent. It is only relevent in the ITU." ::= { sonusSs7NodeEntry 59 } sonusSs7NodeTimerT40 OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "The Timer T40 could be changed from its default using this entry." ::= { sonusSs7NodeEntry 60 } sonusSs7NodeTimerTAcc OBJECT-TYPE SYNTAX Integer32 (3..8) MAX-ACCESS read-write STATUS current DESCRIPTION "Automatic Congestion Control Timer as per ANSI T1.113.4 - 1995. The value of the timer is 5 Seconds." DEFVAL { 5 } ::= { sonusSs7NodeEntry 61 } sonusSs7NodeTimerTCcr OBJECT-TYPE SYNTAX Integer32 (1..3) MAX-ACCESS read-write STATUS current DESCRIPTION "Continuity Check Request Timer. The value As per ANSI T1.113.4 - 1995 is 2 Seconds." DEFVAL { 2 } ::= { sonusSs7NodeEntry 62 } sonusSs7NodeTimerTCcrr OBJECT-TYPE SYNTAX Integer32 (16..31) MAX-ACCESS read-write STATUS current DESCRIPTION "Continuity Check Failed Recived. The value as per ANSI T1.113.4 - 1995 is 20 Seconds." DEFVAL { 20 } ::= { sonusSs7NodeEntry 63 } sonusSs7NodeTimerTCgb OBJECT-TYPE SYNTAX Integer32 (3..8) MAX-ACCESS read-write STATUS current DESCRIPTION "Timer started on recipt of a Circuit Group Block Message. The value as per ANSI T1.113.4 - 1995 is 5 Seconds." DEFVAL { 5 } ::= { sonusSs7NodeEntry 64 } sonusSs7NodeTimerTCra OBJECT-TYPE SYNTAX Integer32 (16..31) MAX-ACCESS read-write STATUS current DESCRIPTION "Timer started when Circuit Reservation Acknowledgment is sent. The time value as per ANSI T1.113.4 - 1995 is 20 seconds." DEFVAL { 20 } ::= { sonusSs7NodeEntry 65 } sonusSs7NodeTimerTCrm OBJECT-TYPE SYNTAX Integer32 (3..4) MAX-ACCESS read-write STATUS current DESCRIPTION "This timer is started when the circuit reservation message is sent. The value as per ANSI T1.113.4 - 1995 is 3 - 4 Seconds. The default is set to 4 seconds." DEFVAL { 4 } ::= { sonusSs7NodeEntry 66 } sonusSs7NodeTimerTCvt OBJECT-TYPE SYNTAX Integer32 (5..12) MAX-ACCESS read-write STATUS current DESCRIPTION "The Timer T CVT is started when the Circuit Validation Test message is sent. This message is only valid for ANSI." DEFVAL { 10 } ::= { sonusSs7NodeEntry 67 } sonusSs7NodeTimerTExm OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "The Timer Exm,d is started when IAM is sent to the succeeding network. This timer has no relevence in the ITU. This timer is in milliseconds" ::= { sonusSs7NodeEntry 68 } sonusSs7NodeTimerTGrs OBJECT-TYPE SYNTAX Integer32 (3..8) MAX-ACCESS read-write STATUS current DESCRIPTION "This timer is started when a circuit group reset message is received. This timer is only relevent in the ANSI network. " DEFVAL { 5 } ::= { sonusSs7NodeEntry 69 } sonusSs7NodeTimerTHga OBJECT-TYPE SYNTAX Integer32 (0..300) MAX-ACCESS read-write STATUS current DESCRIPTION "This timer is started on recognition of carrier loss. It is only relevent in ANSI network. The valid range is 0 to 300 seconds." DEFVAL { 150 } ::= { sonusSs7NodeEntry 70 } sonusSs7NodeTimerTScga OBJECT-TYPE SYNTAX Integer32 (0..120) MAX-ACCESS read-write STATUS current DESCRIPTION "This timer is started when initial demand continuity check fails in the SCGA group. The valid range for this timer is 0 to 120 seconds." DEFVAL { 60 } ::= { sonusSs7NodeEntry 71 } sonusSs7NodeTimerTScgad OBJECT-TYPE SYNTAX Integer32 (5..120) MAX-ACCESS read-write STATUS current DESCRIPTION "This timer is started failure of demand continuity check in the SCGA group." DEFVAL { 65 } ::= { sonusSs7NodeEntry 72 } sonusSs7NodeApplProfileName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..23)) MAX-ACCESS read-write STATUS current DESCRIPTION "The SS7 Node Profile to be applied to the node. The values here are a snap shot only and might have changed since they were set." ::= { sonusSs7NodeEntry 73 } sonusSs7NodeNetworkInd OBJECT-TYPE SYNTAX INTEGER { intl0(1), intl1(2), natl0(3), natl1(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "The setting of the Network Indicator used for this SS7 Node entry." DEFVAL { natl0 } ::= { sonusSs7NodeEntry 74 } sonusSs7NodeSlsBits OBJECT-TYPE SYNTAX Integer32 (4..8) MAX-ACCESS read-write STATUS current DESCRIPTION "The number of SLS bits to use" DEFVAL { 5 } ::= { sonusSs7NodeEntry 75 } sonusSs7NodeTimerTA OBJECT-TYPE SYNTAX Integer32 (0..1000) MAX-ACCESS read-write STATUS current DESCRIPTION "The Bellcore specific timer TA is the guard timer on outgoing SS7 circuit before idling. The value of this timer is 0 to 1000 milliseconds." DEFVAL { 0 } ::= { sonusSs7NodeEntry 76 } sonusSs7NodeTimerTBlom OBJECT-TYPE SYNTAX Integer32 (240..360) MAX-ACCESS read-write STATUS current DESCRIPTION "The Bellcore specific timer TBlom is started when blocking a circuit due to a BLO, and after any call is released; used to notify maintenance." DEFVAL { 300 } ::= { sonusSs7NodeEntry 77 } sonusSs7NodeTimerTCotd OBJECT-TYPE SYNTAX Integer32 (0..500) MAX-ACCESS read-write STATUS current DESCRIPTION "The Bellcore specific timer TCOTd is started when sending IAM requesting continuity check. The value of this timer is in milliseconds." DEFVAL { 0 } ::= { sonusSs7NodeEntry 78 } sonusSs7NodeTimerTCotl OBJECT-TYPE SYNTAX Integer32 (240..300) MAX-ACCESS read-write STATUS current DESCRIPTION "The Bellcore specific timer TCOTl is started when receiving second COT coded failed, awaiting receipt of CCR." DEFVAL { 250 } ::= { sonusSs7NodeEntry 79 } sonusSs7NodeTimerTSus OBJECT-TYPE SYNTAX Integer32 (14..16) MAX-ACCESS read-write STATUS current DESCRIPTION "The Bellcore specific timer TSUS is started when a SUS message is sent by the terminating switch, awaiting called party off-hook or REL." DEFVAL { 15 } ::= { sonusSs7NodeEntry 80 } sonusSs7NodeProfile OBJECT IDENTIFIER ::= { sonusSs7ServicesMIBObjects 3 } sonusSs7NodeProfileNextIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The next valid index to use when creating an entry in the sonusSs7NodeProfileTable." ::= { sonusSs7NodeProfile 1 } sonusSs7NodeProfileTable OBJECT-TYPE SYNTAX SEQUENCE OF SonusSs7NodeProfileEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table specifies the SS7 Node Profile list for the GSX9000 node." ::= { sonusSs7NodeProfile 2 } sonusSs7NodeProfileEntry OBJECT-TYPE SYNTAX SonusSs7NodeProfileEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { sonusSs7NodeProfileIndex } ::= { sonusSs7NodeProfileTable 1 } SonusSs7NodeProfileEntry ::= SEQUENCE { sonusSs7NodeProfileIndex Integer32, sonusSs7NodeProfileName SonusName, sonusSs7PointCodeSize Integer32, sonusSs7PointCodeFormatType SonusPointCodeFormat, sonusSs7ServerProtocol INTEGER, sonusSs7HandShakeInterval Integer32, sonusSs7TimerT1 Integer32, sonusSs7TimerT2 Integer32, sonusSs7TimerT3 Integer32, sonusSs7TimerT4 Integer32, sonusSs7TimerT5 Integer32, sonusSs7TimerT6 Integer32, sonusSs7TimerT7 Integer32, sonusSs7TimerT8 Integer32, sonusSs7TimerT9 Integer32, sonusSs7TimerT10 Integer32, sonusSs7TimerT11 Integer32, sonusSs7TimerT12 Integer32, sonusSs7TimerT13 Integer32, sonusSs7TimerT14 Integer32, sonusSs7TimerT15 Integer32, sonusSs7TimerT16 Integer32, sonusSs7TimerT17 Integer32, sonusSs7TimerT18 Integer32, sonusSs7TimerT19 Integer32, sonusSs7TimerT20 Integer32, sonusSs7TimerT21 Integer32, sonusSs7TimerT22 Integer32, sonusSs7TimerT23 Integer32, sonusSs7TimerT24 Integer32, sonusSs7TimerT25 Integer32, sonusSs7TimerT26 Integer32, sonusSs7TimerT27 Integer32, sonusSs7TimerT28 Integer32, sonusSs7TimerT29 Integer32, sonusSs7TimerT30 Integer32, sonusSs7TimerT31 Integer32, sonusSs7TimerT32 Integer32, sonusSs7TimerT33 Integer32, sonusSs7TimerT34 Integer32, sonusSs7TimerT35 Integer32, sonusSs7TimerT36 Integer32, sonusSs7TimerT37 Integer32, sonusSs7TimerT38 Integer32, sonusSs7TimerT39 Integer32, sonusSs7TimerT40 Integer32, sonusSs7TimerTAcc Integer32, sonusSs7TimerTCcr Integer32, sonusSs7TimerTCcrr Integer32, sonusSs7TimerTCgb Integer32, sonusSs7TimerTCra Integer32, sonusSs7TimerTCrm Integer32, sonusSs7TimerTCvt Integer32, sonusSs7TimerTExm Integer32, sonusSs7TimerTGrs Integer32, sonusSs7TimerTHga Integer32, sonusSs7TimerTScga Integer32, sonusSs7TimerTScgad Integer32, sonusSs7NodeProfileState INTEGER, sonusSs7NodeProfileRowStatus RowStatus, sonusSs7NodeProfileNetworkInd INTEGER, sonusSs7SlsBits Integer32, sonusSs7TimerTA Integer32, sonusSs7TimerTBlom Integer32, sonusSs7TimerTCotd Integer32, sonusSs7TimerTCotl Integer32, sonusSs7TimerTSus Integer32 } sonusSs7NodeProfileIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Identifies the SS7 Node Profile entry" ::= { sonusSs7NodeProfileEntry 1 } sonusSs7NodeProfileName OBJECT-TYPE SYNTAX SonusName MAX-ACCESS read-write STATUS current DESCRIPTION "The name of the Node Profile" ::= { sonusSs7NodeProfileEntry 2 } sonusSs7PointCodeSize OBJECT-TYPE SYNTAX Integer32 (1..32) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the total number of bits in the point code." DEFVAL { 24 } ::= { sonusSs7NodeProfileEntry 3 } sonusSs7PointCodeFormatType OBJECT-TYPE SYNTAX SonusPointCodeFormat MAX-ACCESS read-write STATUS current DESCRIPTION "The Point Code format type being defined." ::= { sonusSs7NodeProfileEntry 4 } sonusSs7ServerProtocol OBJECT-TYPE SYNTAX INTEGER { dgmsProp(1), dgmsRaw(2), tekTali(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The interface used between the SS7 gateway and the SS7 client on the GSX9000" DEFVAL { dgmsProp } ::= { sonusSs7NodeProfileEntry 5 } sonusSs7HandShakeInterval OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-write STATUS current DESCRIPTION "HandShake interval between the client and the server in seconds." ::= { sonusSs7NodeProfileEntry 6 } sonusSs7TimerT1 OBJECT-TYPE SYNTAX Integer32 (4..60) MAX-ACCESS read-write STATUS current DESCRIPTION "The Timer T1 could be changed from its default using this entry. The valid ranges are 4 - 15 seconds for ANSI and 15 - 60 Seconds for ITU." DEFVAL { 10 } ::= { sonusSs7NodeProfileEntry 7 } sonusSs7TimerT2 OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-write STATUS current DESCRIPTION "The Timer T2 could be changed from its default using this entry. The valid value for ITU is 3 Minutes. This timer has no relevence in the ANSI network. " DEFVAL { 180 } ::= { sonusSs7NodeProfileEntry 8 } sonusSs7TimerT3 OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-write STATUS current DESCRIPTION "The T3 timer is started on receipt of an Overload message in the ITU network. This has no relevence in the ANSI network. The valid ITU recommended value is 120 Seconds " DEFVAL { 120 } ::= { sonusSs7NodeProfileEntry 9 } sonusSs7TimerT4 OBJECT-TYPE SYNTAX Integer32 (300..900) MAX-ACCESS read-write STATUS current DESCRIPTION "The Timer T4 could be changed from its default using this entry." DEFVAL { 600 } ::= { sonusSs7NodeProfileEntry 10 } sonusSs7TimerT5 OBJECT-TYPE SYNTAX Integer32 (60..900) MAX-ACCESS read-write STATUS current DESCRIPTION "The T5 Timer is started when the release message is sent. The valid values as per the specifications are 60 seconds for the ANSI and 300 to 900 seconds for ITU." DEFVAL { 60 } ::= { sonusSs7NodeProfileEntry 11 } sonusSs7TimerT6 OBJECT-TYPE SYNTAX Integer32 (10..32) MAX-ACCESS read-write STATUS current DESCRIPTION "The timer T6 is started when the suspend message is received. The valid range for this timer is 10 to 32 seconds." DEFVAL { 22 } ::= { sonusSs7NodeProfileEntry 12 } sonusSs7TimerT7 OBJECT-TYPE SYNTAX Integer32 (20..30) MAX-ACCESS read-write STATUS current DESCRIPTION "The Timer T7 could be changed from its default using this entry." DEFVAL { 25 } ::= { sonusSs7NodeProfileEntry 13 } sonusSs7TimerT8 OBJECT-TYPE SYNTAX Integer32 (10..15) MAX-ACCESS read-write STATUS current DESCRIPTION "The T8 timer is timer to be started with continuity check has been indicated in the IAM. The valid range is 10 to 15 seconds." DEFVAL { 13 } ::= { sonusSs7NodeProfileEntry 14 } sonusSs7TimerT9 OBJECT-TYPE SYNTAX Integer32 (120..240) MAX-ACCESS read-write STATUS current DESCRIPTION "The Timer T9 started when outgoing international exchange recieves an ACM. The valid range is 120 to 240 seconds." DEFVAL { 180 } ::= { sonusSs7NodeProfileEntry 15 } sonusSs7TimerT10 OBJECT-TYPE SYNTAX Integer32 (240..360) MAX-ACCESS read-write STATUS current DESCRIPTION "The Timer T10 is started when the last digit is recived in interworking situations. This timer has no relevence to ANSI." ::= { sonusSs7NodeProfileEntry 16 } sonusSs7TimerT11 OBJECT-TYPE SYNTAX Integer32 (15..20) MAX-ACCESS read-write STATUS current DESCRIPTION "The Timer T11 is started when the latest address message is received in interworking situations. The valid range is 15 to 20 seconds." DEFVAL { 17 } ::= { sonusSs7NodeProfileEntry 17 } sonusSs7TimerT12 OBJECT-TYPE SYNTAX Integer32 (4..60) MAX-ACCESS read-write STATUS current DESCRIPTION "The Timer T12 is started when a blocking message is sent. The valid ranges are 4 to 15 seconds for ANSI and 15 to 60 seconds for ITU." DEFVAL { 10 } ::= { sonusSs7NodeProfileEntry 18 } sonusSs7TimerT13 OBJECT-TYPE SYNTAX Integer32 (60..900) MAX-ACCESS read-write STATUS current DESCRIPTION "The Timer T13 is started when the initial blocking messge is sent. The valid value for ANSI is 60 seconds and for ITU is between 300 and 900 seconds." DEFVAL { 60 } ::= { sonusSs7NodeProfileEntry 19 } sonusSs7TimerT14 OBJECT-TYPE SYNTAX Integer32 (4..60) MAX-ACCESS read-write STATUS current DESCRIPTION "The Timer T14 is started when an unblocking message is sent. The valid values are 4 to 15 seconds for ANSI and 15 to 60 seconds for ITU" DEFVAL { 10 } ::= { sonusSs7NodeProfileEntry 20 } sonusSs7TimerT15 OBJECT-TYPE SYNTAX Integer32 (60..900) MAX-ACCESS read-write STATUS current DESCRIPTION "The Timer T15 is started when the initial unblocking message is sent. The valid values are 60 seconds for ANSI and 300 to 900 seconds for ITU." DEFVAL { 60 } ::= { sonusSs7NodeProfileEntry 21 } sonusSs7TimerT16 OBJECT-TYPE SYNTAX Integer32 (4..60) MAX-ACCESS read-write STATUS current DESCRIPTION "The Timer T16 is started when the reset circuit is started which was not due to expiry of T5. The valid ranges are 4 to 15 seconds for ANSI and 15 to 60 seconds for ITU." DEFVAL { 10 } ::= { sonusSs7NodeProfileEntry 22 } sonusSs7TimerT17 OBJECT-TYPE SYNTAX Integer32 (60..900) MAX-ACCESS read-write STATUS current DESCRIPTION "The Timer T17 is started when initial reset message is sent. The valid values are 60 seconds for ANSI and 300 to 900 for ITU." DEFVAL { 60 } ::= { sonusSs7NodeProfileEntry 23 } sonusSs7TimerT18 OBJECT-TYPE SYNTAX Integer32 (4..60) MAX-ACCESS read-write STATUS current DESCRIPTION "The Timer T18 is started when circuit group blocking message is sent. The valid values are 4 to 15 seconds for ANSI and 15 to 60 seconds for ITU." DEFVAL { 10 } ::= { sonusSs7NodeProfileEntry 24 } sonusSs7TimerT19 OBJECT-TYPE SYNTAX Integer32 (60..900) MAX-ACCESS read-write STATUS current DESCRIPTION "The Timer T19 is started when initial group blocking message is sent. The valid values are 60 seconds for ANSI and 300 to 900 seconds for ITU." DEFVAL { 60 } ::= { sonusSs7NodeProfileEntry 25 } sonusSs7TimerT20 OBJECT-TYPE SYNTAX Integer32 (4..60) MAX-ACCESS read-write STATUS current DESCRIPTION "The Timer T20 is started when group unblocking message is sent. The valid ranges are 4 to 15 seconds for ANSI and 15 to 60 seconds for ITU." DEFVAL { 10 } ::= { sonusSs7NodeProfileEntry 26 } sonusSs7TimerT21 OBJECT-TYPE SYNTAX Integer32 (60..900) MAX-ACCESS read-write STATUS current DESCRIPTION "The Timer T21 is started when initial group blocking message is sent. The valid values are 60 seconds for ANSI and 300 to 900 seconds for ITU." DEFVAL { 60 } ::= { sonusSs7NodeProfileEntry 27 } sonusSs7TimerT22 OBJECT-TYPE SYNTAX Integer32 (4..60) MAX-ACCESS read-write STATUS current DESCRIPTION "The Timer T22 is started when circuit group reset message is sent. The valid values are 4 to 15 seconds for ANSI and 15 to 60 seconds for ITU." DEFVAL { 10 } ::= { sonusSs7NodeProfileEntry 28 } sonusSs7TimerT23 OBJECT-TYPE SYNTAX Integer32 (60..900) MAX-ACCESS read-write STATUS current DESCRIPTION "The Timer T23 is started when initial group reset message is sent. The valid values are 60 seconds for the ANSI and 300 to 900 seconds for the ITU." DEFVAL { 60 } ::= { sonusSs7NodeProfileEntry 29 } sonusSs7TimerT24 OBJECT-TYPE SYNTAX Integer32 (1..2) MAX-ACCESS read-write STATUS current DESCRIPTION "The Timer T24 is started when check tone is sent. The value is less than 2 seconds." DEFVAL { 1 } ::= { sonusSs7NodeProfileEntry 30 } sonusSs7TimerT25 OBJECT-TYPE SYNTAX Integer32 (1..10) MAX-ACCESS read-write STATUS current DESCRIPTION "The Timer T25 is started when initial continuity check failure is detected. The range is 1 to 10 seconds." DEFVAL { 5 } ::= { sonusSs7NodeProfileEntry 31 } sonusSs7TimerT26 OBJECT-TYPE SYNTAX Integer32 (60..180) MAX-ACCESS read-write STATUS current DESCRIPTION "The Timer T26 is started when a second or subsequent continuity failure is detected. The valid value are 60 to 180 seconds." DEFVAL { 120 } ::= { sonusSs7NodeProfileEntry 32 } sonusSs7TimerT27 OBJECT-TYPE SYNTAX Integer32 (180..36000) MAX-ACCESS read-write STATUS current DESCRIPTION "The Timer T27 is started when a continuity fail message is recieved. The valid values are more than 180 seconds for ANSI and 240 seconds for ITU. " DEFVAL { 240 } ::= { sonusSs7NodeProfileEntry 33 } sonusSs7TimerT28 OBJECT-TYPE SYNTAX Integer32 (5..12) MAX-ACCESS read-write STATUS current DESCRIPTION "The Timer T28 is started when Circuit Query Message is sent. The valid value is 10 seconds." DEFVAL { 10 } ::= { sonusSs7NodeProfileEntry 34 } sonusSs7TimerT29 OBJECT-TYPE SYNTAX Integer32 (300..600) MAX-ACCESS read-write STATUS current DESCRIPTION "The Timer T29 is started when Congestion indication is received when T29 is not running. The valid range is 300 to 600 milli second. This timer has no relevence for ANSI." ::= { sonusSs7NodeProfileEntry 35 } sonusSs7TimerT30 OBJECT-TYPE SYNTAX Integer32 (5..10) MAX-ACCESS read-write STATUS current DESCRIPTION "The Timer T30 is stared when congestion indication is recieved when T29 is not running. The valid range is 5 to 10 seconds for the ITU. This timer has no relevence under ANSI." ::= { sonusSs7NodeProfileEntry 36 } sonusSs7TimerT31 OBJECT-TYPE SYNTAX Integer32 (360..65520) MAX-ACCESS read-write STATUS current DESCRIPTION "The Timer T31 is started on release of ISUP signalling connection based on CO SCCP. The value should be set to greater than 360 seconds" DEFVAL { 420 } ::= { sonusSs7NodeProfileEntry 37 } sonusSs7TimerT32 OBJECT-TYPE SYNTAX Integer32 (3..5) MAX-ACCESS read-write STATUS current DESCRIPTION "The Timer T32 is started when the first end-to-end message is recived. Under ANSI this timer is started after the response to such a message is sent. The valid values are 3 to 5 seconds. " DEFVAL { 4 } ::= { sonusSs7NodeProfileEntry 38 } sonusSs7TimerT33 OBJECT-TYPE SYNTAX Integer32 (12..15) MAX-ACCESS read-write STATUS current DESCRIPTION "The Timer T33 is started when Information Request Message is sent. The valid range is 12 to 15 seconds." DEFVAL { 14 } ::= { sonusSs7NodeProfileEntry 39 } sonusSs7TimerT34 OBJECT-TYPE SYNTAX Integer32 (2..15) MAX-ACCESS read-write STATUS current DESCRIPTION "The Timer T34 is started when Loop Back Acknowledgement is sent under ANSI. The Timer T34 is started when segmentation is received for IAM, ACM, CPG, ANM or CON under ITU. The valid range for ANSI is 10 to 15 seconds. The valid range for ITU is 2 to 4 seconds." ::= { sonusSs7NodeProfileEntry 40 } sonusSs7TimerT35 OBJECT-TYPE SYNTAX Integer32 (15..20) MAX-ACCESS read-write STATUS current DESCRIPTION "The Timer T35 is started when the last digit recieved is not an ST digit or the fixed number of digits have been recieved. This procedure is only valid for overlap hence ITU. This timer has no relevence in ANSI." DEFVAL { 18 } ::= { sonusSs7NodeProfileEntry 41 } sonusSs7TimerT36 OBJECT-TYPE SYNTAX Integer32 (2..15) MAX-ACCESS read-write STATUS current DESCRIPTION "The Timer T36 is started when IAM is recived with a segmentation indication for ANSI. This timer is started when transit or incoming international exchange recieves Continuity check request message. The valid range for ANSI is 2 to 4 seconds and 10 to 15 seconds for ITU. " ::= { sonusSs7NodeProfileEntry 42 } sonusSs7TimerT37 OBJECT-TYPE SYNTAX Integer32 (2..30) MAX-ACCESS read-write STATUS current DESCRIPTION "The Timer T37 is started when User Part Availability test is started under ANSI. This timer is started when a request for and Echo control device is sent to another exchange under ITU. The valid value for ANSI is 30 seconds and for ITU is 2 to 4 seconds." ::= { sonusSs7NodeProfileEntry 43 } sonusSs7TimerT38 OBJECT-TYPE SYNTAX Integer32 (10..60) MAX-ACCESS read-write STATUS current DESCRIPTION "The Timer T38 is started when a suspend message is sent to the preceding switch. This timer is only relevent under ITU." DEFVAL { 30 } ::= { sonusSs7NodeProfileEntry 44 } sonusSs7TimerT39 OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "The Timer T39 is started when MCID request is sent. It is only relevent in the ITU." ::= { sonusSs7NodeProfileEntry 45 } sonusSs7TimerT40 OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "The Timer T40 could be changed from its default using this entry." ::= { sonusSs7NodeProfileEntry 46 } sonusSs7TimerTAcc OBJECT-TYPE SYNTAX Integer32 (3..8) MAX-ACCESS read-write STATUS current DESCRIPTION "Automatic Congestion Control Timer as per ANSI T1.113.4 - 1995. The value of the timer is 5 Seconds." DEFVAL { 5 } ::= { sonusSs7NodeProfileEntry 47 } sonusSs7TimerTCcr OBJECT-TYPE SYNTAX Integer32 (1..3) MAX-ACCESS read-write STATUS current DESCRIPTION "Continuity Check Request Timer. The value As per ANSI T1.113.4 - 1995 is 2 Seconds." DEFVAL { 2 } ::= { sonusSs7NodeProfileEntry 48 } sonusSs7TimerTCcrr OBJECT-TYPE SYNTAX Integer32 (16..31) MAX-ACCESS read-write STATUS current DESCRIPTION "Continuity Check Failed Recived. The value as per ANSI T1.113.4 - 1995 is 20 Seconds." DEFVAL { 20 } ::= { sonusSs7NodeProfileEntry 49 } sonusSs7TimerTCgb OBJECT-TYPE SYNTAX Integer32 (3..8) MAX-ACCESS read-write STATUS current DESCRIPTION "Timer started on recipt of a Circuit Group Block Message. The value as per ANSI T1.113.4 - 1995 is 5 Seconds." DEFVAL { 5 } ::= { sonusSs7NodeProfileEntry 50 } sonusSs7TimerTCra OBJECT-TYPE SYNTAX Integer32 (16..31) MAX-ACCESS read-write STATUS current DESCRIPTION "Timer started when Circuit Reservation Acknowledgment is sent. The time value as per ANSI T1.113.4 - 1995 is 20 seconds." DEFVAL { 20 } ::= { sonusSs7NodeProfileEntry 51 } sonusSs7TimerTCrm OBJECT-TYPE SYNTAX Integer32 (3..4) MAX-ACCESS read-write STATUS current DESCRIPTION "This timer is started when the circuit reservation message is sent. The value as per ANSI T1.113.4 - 1995 is 3 - 4 Seconds. The default is set to 4 seconds." DEFVAL { 4 } ::= { sonusSs7NodeProfileEntry 52 } sonusSs7TimerTCvt OBJECT-TYPE SYNTAX Integer32 (5..12) MAX-ACCESS read-write STATUS current DESCRIPTION "The Timer T CVT is started when the Circuit Validation Test message is sent. This message is only valid for ANSI." DEFVAL { 10 } ::= { sonusSs7NodeProfileEntry 53 } sonusSs7TimerTExm OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "The Timer Exm,d is started when IAM is sent to the succeeding network. This timer has no relevence in the ITU. This timer is in milliseconds." ::= { sonusSs7NodeProfileEntry 54 } sonusSs7TimerTGrs OBJECT-TYPE SYNTAX Integer32 (3..8) MAX-ACCESS read-write STATUS current DESCRIPTION "This timer is started when a circuit group reset message is received. This timer is only relevent in the ANSI network. " DEFVAL { 5 } ::= { sonusSs7NodeProfileEntry 55 } sonusSs7TimerTHga OBJECT-TYPE SYNTAX Integer32 (0..300) MAX-ACCESS read-write STATUS current DESCRIPTION "This timer is started on recognition of carrier loss. It is only relevent in ANSI network. The valid range is 0 to 300 seconds." DEFVAL { 150 } ::= { sonusSs7NodeProfileEntry 56 } sonusSs7TimerTScga OBJECT-TYPE SYNTAX Integer32 (0..120) MAX-ACCESS read-write STATUS current DESCRIPTION "This timer is started when initial demand continuity check fails in the SCGA group. The valid range for this timer is 0 to 120 seconds." DEFVAL { 60 } ::= { sonusSs7NodeProfileEntry 57 } sonusSs7TimerTScgad OBJECT-TYPE SYNTAX Integer32 (5..120) MAX-ACCESS read-write STATUS current DESCRIPTION "This timer is started failure of demand continuity check in the SCGA group." DEFVAL { 65 } ::= { sonusSs7NodeProfileEntry 58 } sonusSs7NodeProfileState OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabled(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The administrative state of this object." DEFVAL { disabled } ::= { sonusSs7NodeProfileEntry 59 } sonusSs7NodeProfileRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-write STATUS current DESCRIPTION "" ::= { sonusSs7NodeProfileEntry 60 } sonusSs7NodeProfileNetworkInd OBJECT-TYPE SYNTAX INTEGER { intl0(1), intl1(2), natl0(3), natl1(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "The setting of the Network Indicator used for this SS7 Node entry." DEFVAL { natl0 } ::= { sonusSs7NodeProfileEntry 61 } sonusSs7SlsBits OBJECT-TYPE SYNTAX Integer32 (4..8) MAX-ACCESS read-write STATUS current DESCRIPTION "The number of SLS bits to use" DEFVAL { 5 } ::= { sonusSs7NodeProfileEntry 62 } sonusSs7TimerTA OBJECT-TYPE SYNTAX Integer32 (0..1000) MAX-ACCESS read-write STATUS current DESCRIPTION "The Bellcore specific timer TA is started when a RLC message is sent by the switch. The value of this timer is 0 to 1000 milliseconds." DEFVAL { 500 } ::= { sonusSs7NodeProfileEntry 63 } sonusSs7TimerTBlom OBJECT-TYPE SYNTAX Integer32 (240..360) MAX-ACCESS read-write STATUS current DESCRIPTION "The Bellcore specific timer TBlom is started when blocking a circuit due to a BLO, and after any call is released; used to notify maintenance." DEFVAL { 300 } ::= { sonusSs7NodeProfileEntry 64 } sonusSs7TimerTCotd OBJECT-TYPE SYNTAX Integer32 (0..500) MAX-ACCESS read-write STATUS current DESCRIPTION "The Bellcore specific timer TCOTd is started when sending IAM requesting continuity check. The value of this timer is in milliseconds." DEFVAL { 250 } ::= { sonusSs7NodeProfileEntry 65 } sonusSs7TimerTCotl OBJECT-TYPE SYNTAX Integer32 (240..300) MAX-ACCESS read-write STATUS current DESCRIPTION "The Bellcore specific timer TCOTl is started when receiving second COT coded failed, awaiting receipt of CCR." DEFVAL { 300 } ::= { sonusSs7NodeProfileEntry 66 } sonusSs7TimerTSus OBJECT-TYPE SYNTAX Integer32 (14..16) MAX-ACCESS read-write STATUS current DESCRIPTION "The Bellcore specific timer TSUS is started when a SUS message is sent by the terminating switch, awaiting called party off-hook or REL." DEFVAL { 15 } ::= { sonusSs7NodeProfileEntry 67 } sonusSs7ServicesMIBNotifications OBJECT IDENTIFIER ::= { sonusSs7ServicesMIB 2 } sonusSs7ServicesMIBNotificationsPrefix OBJECT IDENTIFIER ::= { sonusSs7ServicesMIBNotifications 0 } sonusSs7ServicesMIBNotificationsObjects OBJECT IDENTIFIER ::= { sonusSs7ServicesMIBNotifications 1 } sonusSs7NodeServiceType OBJECT-TYPE SYNTAX DisplayString (SIZE(1..6)) MAX-ACCESS read-only STATUS current DESCRIPTION "The type of service supported by this SS7 node connection (ISUP or TCAP)." ::= { sonusSs7ServicesMIBNotificationsObjects 1 } sonusSs7NodeStateChangeReason OBJECT-TYPE SYNTAX DisplayString (SIZE(1..101)) MAX-ACCESS read-only STATUS current DESCRIPTION "The reason why this SS7 node connection has changed state." ::= { sonusSs7ServicesMIBNotificationsObjects 2 } sonusSs7NodeCurrentState OBJECT-TYPE SYNTAX INTEGER { offline(1), active(2), initializing(3), failed(4), disabled(5), congested(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "The current state of this SS7 node connection." ::= { sonusSs7ServicesMIBNotificationsObjects 3 } sonusSs7NodeAffectedPointCode OBJECT-TYPE SYNTAX PointCode MAX-ACCESS read-only STATUS current DESCRIPTION "The SS7 point code affected by this MTP state change." ::= { sonusSs7ServicesMIBNotificationsObjects 4 } sonusSs7NodeConnectionEstablishedNotification NOTIFICATION-TYPE OBJECTS { sonusSs7NodeName, sonusSs7NodeGatewayAssignment, sonusSs7NodeServiceType, sonusEventDescription, sonusEventClass, sonusEventLevel } STATUS current DESCRIPTION "This trap indicates that a connection has been established to the specified SS7 gateway. Information provided by this trap includes the name of the connected SS7 node, the name of the SS7 gateway on which the node resides, and the type of SS7 service that has been established (ISUP or TCAP)." ::= { sonusSs7ServicesMIBNotificationsPrefix 1 } sonusSs7NodeConnectionFailedNotification NOTIFICATION-TYPE OBJECTS { sonusSs7NodeName, sonusSs7NodeGatewayAssignment, sonusSs7NodeServiceType, sonusSs7NodeStateChangeReason, sonusEventDescription, sonusEventClass, sonusEventLevel } STATUS current DESCRIPTION "This trap indicates that an established connection to an SS7 gateway has failed. Information provided by this trap includes the name of the failed SS7 node, the name of the SS7 gateway on which the node resides, the type of SS7 service affected by this failure, and the reason why the connection has failed." ::= { sonusSs7ServicesMIBNotificationsPrefix 2 } sonusSs7NodeConnectionStateChangeNotification NOTIFICATION-TYPE OBJECTS { sonusSs7NodeName, sonusSs7NodeGatewayAssignment, sonusSs7NodeServiceType, sonusSs7NodeCurrentState, sonusSs7NodeStateChangeReason, sonusEventDescription, sonusEventClass, sonusEventLevel } STATUS current DESCRIPTION "This trap indicates that an established connection to an SS7 gateway has changed state. Information provided by this trap includes the name of the affected SS7 node, the name of the SS7 gateway on which the node resides, the type of SS7 service affected by this failure, the new state of the node, and the reason for the state change." ::= { sonusSs7ServicesMIBNotificationsPrefix 3 } sonusSs7NodeMtpStateChangeNotification NOTIFICATION-TYPE OBJECTS { sonusSs7NodeName, sonusSs7NodeGatewayAssignment, sonusSs7NodeServiceType, sonusSs7NodeMtpStatus, sonusSs7NodeAffectedPointCode, sonusEventDescription, sonusEventClass, sonusEventLevel } STATUS current DESCRIPTION "This trap indicates that a MTP state change event has been received from the SS7 gateway, affecting the specified destination (or remote) point code (DPC). Information provided by this trap includes the name of the affected SS7 node, the name of the SS7 gateway on which the node resides, the updated MTP state, and the DPC affected by this event." ::= { sonusSs7ServicesMIBNotificationsPrefix 4 } END -- end of module SONUS-SS7-SERVICES-MIB.