-- -- This SMIv2 module has been generated by smidump 0.2-cvs. Do not edit. -- SONUS-NODE-RESOURCES-MIB DEFINITIONS ::= BEGIN IMPORTS Integer32, IpAddress, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-TYPE FROM SNMPv2-SMI DisplayString, RowStatus FROM SNMPv2-TC sonusEventClass, sonusEventDescription, sonusEventLevel FROM SONUS-COMMON-MIB sonusResourcesMIBs FROM SONUS-SMI SonusAdminState, SonusName, SonusNameReference FROM SONUS-TC; sonusNodeResourcesMIB MODULE-IDENTITY LAST-UPDATED "200107310000Z" ORGANIZATION "Sonus Networks, Inc." CONTACT-INFO " Customer Support Sonus Networks, Inc, 5 carlisle Road Westford, MA 01886 USA Tel: 978-692-8999 Fax: 978-392-9118 E-mail: cs.snmp@sonusnet.com" DESCRIPTION "The MIB Module for Node Resources Management." ::= { sonusResourcesMIBs 2 } sonusNodeResourcesMIBObjects OBJECT IDENTIFIER ::= { sonusNodeResourcesMIB 1 } sonusServProfile OBJECT IDENTIFIER ::= { sonusNodeResourcesMIBObjects 1 } sonusServProfileNextIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS deprecated DESCRIPTION "This field is deprecated. The next valid index to use when creating an entry in the sonusServProfileTable." ::= { sonusServProfile 1 } sonusServProfileTable OBJECT-TYPE SYNTAX SEQUENCE OF SonusServProfileEntry MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION "This field is deprecated. This table specifies the service profile list for the node." ::= { sonusServProfile 2 } sonusServProfileEntry OBJECT-TYPE SYNTAX SonusServProfileEntry MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION "This field is deprecated. " INDEX { sonusServProfileIndex } ::= { sonusServProfileTable 1 } SonusServProfileEntry ::= SEQUENCE { sonusServProfileIndex Integer32, sonusServProfileState INTEGER, sonusServProfileName SonusName, sonusServProfileType INTEGER, sonusServProfileVCktEncoding INTEGER, sonusServProfileVCktBandwidth Integer32, sonusServProfileVCktNecEnable INTEGER, sonusServProfileVPktEncoding INTEGER, sonusServProfileVPktFrameSize Integer32, sonusServProfileVPktFramesPerPacket Integer32, sonusServProfileVPktMaxNetworkJitter Integer32, sonusServProfileVPktTosValue Integer32, sonusServProfileCttTestType INTEGER, sonusServProfileCttTimeout Integer32, sonusServProfileCttMinDetectTime Integer32, sonusServProfileCttMinReleaseTime Integer32, sonusServProfileCapability INTEGER, sonusServProfileDPktRestrictedCfg INTEGER, sonusServProfileDPktRtpPayloadType Integer32, sonusServProfileDPktMaxNetworkJitter Integer32, sonusServProfileRowStatus RowStatus } sonusServProfileIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS deprecated DESCRIPTION "This field is deprecated. Identifies the target service profile entry." ::= { sonusServProfileEntry 1 } sonusServProfileState OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabled(2) } MAX-ACCESS read-write STATUS deprecated DESCRIPTION "This field is deprecated. The administrative state of this service profile entry." DEFVAL { disabled } ::= { sonusServProfileEntry 2 } sonusServProfileName OBJECT-TYPE SYNTAX SonusName MAX-ACCESS read-write STATUS deprecated DESCRIPTION "This field is deprecated. The user name of this service profile." ::= { sonusServProfileEntry 3 } sonusServProfileType OBJECT-TYPE SYNTAX INTEGER { circuit(1), packet(2) } MAX-ACCESS read-write STATUS deprecated DESCRIPTION "This field is deprecated. The type of endpoint (circuit or packet) supported by this service profile. Circuit endpoints support all the VCkt and VPkt profile parameters for echo cancellation and packetization. Packet endpoints support only the VPkt parameters for packetization." DEFVAL { circuit } ::= { sonusServProfileEntry 4 } sonusServProfileVCktEncoding OBJECT-TYPE SYNTAX INTEGER { g711ulaw(1), g711alaw(2), none(5) } MAX-ACCESS read-write STATUS deprecated DESCRIPTION "This field is deprecated. The audio encoding method to be performed on the voice data received from, and destined to the PSTN. The default encoding method is G.711 Ulaw." DEFVAL { g711ulaw } ::= { sonusServProfileEntry 5 } sonusServProfileVCktBandwidth OBJECT-TYPE SYNTAX Integer32 (1..24) MAX-ACCESS read-write STATUS deprecated DESCRIPTION "This field is deprecated. The number of DS0 channels to group for Nx64 connections. Valid entries are 1 to 24 channels, allowing up to a complete set of T1 channels to be grouped at a single connection. The default bandwidth is 1 channel." DEFVAL { 1 } ::= { sonusServProfileEntry 6 } sonusServProfileVCktNecEnable OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabled(2) } MAX-ACCESS read-write STATUS deprecated DESCRIPTION "This field is deprecated. Specifies whether Network Echo Cancellation (NEC) is enabled for the channel. When enabled, NEC is enabled acording to the appropriate NEC configuration parameters. When disabled, the Voice Packet Assembler/Disassember (VPAD) operates in a circuit emulation mode." DEFVAL { enabled } ::= { sonusServProfileEntry 7 } sonusServProfileVPktEncoding OBJECT-TYPE SYNTAX INTEGER { g711ulaw(1), g711alaw(2), g7231(3), g729a(4), none(5) } MAX-ACCESS read-write STATUS deprecated DESCRIPTION "This field is deprecated. The audio encoding method to be performed on the packet data received from, and destined to the IP network. The default encoding method is G.711 Ulaw." DEFVAL { g711ulaw } ::= { sonusServProfileEntry 8 } sonusServProfileVPktFrameSize OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS deprecated DESCRIPTION "This field is deprecated. Specifies the number of samples per frame. For G.711 encoding mode, value must be a multiple of 8 samples. For G.723 encoding mode, value must be a multiple of 240 samples. For G.729A, value must be a multiple of 80 samples. Note that 8 samples represent one millisecond of voice data. A value of 0 specifies a frame size equal to the minimum for the encoding method (e.g 8 samples for G.711)" DEFVAL { 8 } ::= { sonusServProfileEntry 9 } sonusServProfileVPktFramesPerPacket OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS deprecated DESCRIPTION "This field is deprecated. Specifies the number of frames to transmit per packet. For G.711 encoding mode, valid values range from 5 to 40 frames, in increments of 5 frames. The default value for G.711 is 10 frames per packet. For G.723 encoding mode, valid values are 1 or 2, with a default value of 1 frame per packet. A value of 0 specifies the number of frames per packet equal to the default value for the encoding mode (e.g. 10 frames per packet for G.711)." DEFVAL { 10 } ::= { sonusServProfileEntry 10 } sonusServProfileVPktMaxNetworkJitter OBJECT-TYPE SYNTAX Integer32 (40..400) MAX-ACCESS read-write STATUS deprecated DESCRIPTION "This field is deprecated. Specifies the maximum expected network jitter across the IP network in increments of 125usec. This value defines the size of the initial playout buffer required to absorb the maximum expected packet delay across the network. The minimum value is 40 (5msec) and the maximum value is 400 (50msec), with a default value of 80 (10msec)." DEFVAL { 80 } ::= { sonusServProfileEntry 11 } sonusServProfileVPktTosValue OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-write STATUS deprecated DESCRIPTION "This field is deprecated. Specifies the Type Of Service (TOS) parameters to be provided in the IP header for voice packets. The TOS value is specified as an 8-bit hex value 0x00-0xFF allowing complete flexibility with respect to the contents of the TOS byte." DEFVAL { 0 } ::= { sonusServProfileEntry 12 } sonusServProfileCttTestType OBJECT-TYPE SYNTAX INTEGER { remoteLoopback(1), remote2Wire(2), remote4Wire(3) } MAX-ACCESS read-write STATUS deprecated DESCRIPTION "This field is deprecated. For ISUP service profiles, specifies the type of continuity test to perform, based on the configuration of the remote switch or trunk connection. The remoteLoopback test is used when the remote switch will loop back channel being tested. The remote2Wire test is used when the remote switch supports the 2 wire continuity test procedure. And the remote4Wire test mode is used when the remote switch supports the 4 wire continuity test procedure. The default value is remoteLoopback." DEFVAL { remoteLoopback } ::= { sonusServProfileEntry 13 } sonusServProfileCttTimeout OBJECT-TYPE SYNTAX Integer32 (1..10) MAX-ACCESS read-write STATUS deprecated DESCRIPTION "This field is deprecated. For ISUP service profiles, specifies the overall test timeout value. The continuity test will be declared failed if the continuity tone is not detected within this timeout period. The timeout is specified in seconds, with a default value of 2 seconds." DEFVAL { 2 } ::= { sonusServProfileEntry 14 } sonusServProfileCttMinDetectTime OBJECT-TYPE SYNTAX Integer32 (10..60) MAX-ACCESS read-write STATUS deprecated DESCRIPTION "This field is deprecated. For ISUP service profiles, specifies the minimum time to detect the presence of the continuity test tone. The minimum detect time is specified in milliseconds, with a default time of 45 ms." DEFVAL { 45 } ::= { sonusServProfileEntry 15 } sonusServProfileCttMinReleaseTime OBJECT-TYPE SYNTAX Integer32 (10..40) MAX-ACCESS read-write STATUS deprecated DESCRIPTION "This field is deprecated. For ISUP service profiles, specifies the minimum time to detect that the continuity test tone has been removed and is no longer present. The minimum release time is specified in milliseconds, with a default time of 25 ms." DEFVAL { 25 } ::= { sonusServProfileEntry 16 } sonusServProfileCapability OBJECT-TYPE SYNTAX INTEGER { voiceOnly(1), circuitModeData(2), voiceOrCircuitModeData(3) } MAX-ACCESS read-write STATUS deprecated DESCRIPTION "This field is deprecated. Specifies the data capabilities for the circuit. This parameter specifies whether voice only, circuit mode data only, or both voice and circuit mode data can be supported by the circuit." DEFVAL { voiceOrCircuitModeData } ::= { sonusServProfileEntry 17 } sonusServProfileDPktRestrictedCfg OBJECT-TYPE SYNTAX INTEGER { unrestricted(1), restricted(2) } MAX-ACCESS read-write STATUS deprecated DESCRIPTION "This field is deprecated. Specifies whether the circuit may support 64 Kbit/s unrestricted data, or if the circuit supports 56 Kbit/s restricted data." DEFVAL { unrestricted } ::= { sonusServProfileEntry 18 } sonusServProfileDPktRtpPayloadType OBJECT-TYPE SYNTAX Integer32 (0..127) MAX-ACCESS read-write STATUS deprecated DESCRIPTION "This field is deprecated. Specifies the RTP payload type to be included in the RTP header of the voice data packet" DEFVAL { 56 } ::= { sonusServProfileEntry 19 } sonusServProfileDPktMaxNetworkJitter OBJECT-TYPE SYNTAX Integer32 (40..400) MAX-ACCESS read-write STATUS deprecated DESCRIPTION "This field is deprecated. Specifies the maximum expected network jitter across the network for data calls in increments of 125usec. This value defines the size of the initial playout buffer required to absorb the maximum expected packet delay across the network. A separate value for data calls is provided to allow a single service profile to specify the jitter buffer size for both voice calls and data calls. The minimum value is 40 (5msec) and the maximum value is 400 (50msec), with a default value of 400 (50msec)." DEFVAL { 400 } ::= { sonusServProfileEntry 20 } sonusServProfileRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-write STATUS deprecated DESCRIPTION "This field is deprecated. " ::= { sonusServProfileEntry 21 } sonusSonicBusStatTable OBJECT-TYPE SYNTAX SEQUENCE OF SonusSonicBusStatEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table presents Sonic Bus statistics for the node." ::= { sonusNodeResourcesMIBObjects 2 } sonusSonicBusStatEntry OBJECT-TYPE SYNTAX SonusSonicBusStatEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { sonusSonicBusStatShelfIndex } ::= { sonusSonicBusStatTable 1 } SonusSonicBusStatEntry ::= SEQUENCE { sonusSonicBusStatShelfIndex Integer32, sonusSonicBusStatNumCalls Integer32, sonusSonicBusStatBwAllocated Integer32, sonusSonicBusStatSduCount Integer32 } sonusSonicBusStatShelfIndex OBJECT-TYPE SYNTAX Integer32 (1..6) MAX-ACCESS read-only STATUS current DESCRIPTION "Identifies the target shelf." ::= { sonusSonicBusStatEntry 1 } sonusSonicBusStatNumCalls OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the number of active calls on the shelf." ::= { sonusSonicBusStatEntry 2 } sonusSonicBusStatBwAllocated OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the percentage of Sonic Bus bandwidth allocated to the active calls on the shelf." ::= { sonusSonicBusStatEntry 3 } sonusSonicBusStatSduCount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the number of Sonic Bus data units allocated to the active calls on the shelf." ::= { sonusSonicBusStatEntry 4 } sonusActiveCallTable OBJECT-TYPE SYNTAX SEQUENCE OF SonusActiveCallEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table presents the active call data for the node." ::= { sonusNodeResourcesMIBObjects 3 } sonusActiveCallEntry OBJECT-TYPE SYNTAX SonusActiveCallEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { sonusActiveCallShelfIndex, sonusActiveCallSlotIndex, sonusActiveCallIndex } ::= { sonusActiveCallTable 1 } SonusActiveCallEntry ::= SEQUENCE { sonusActiveCallShelfIndex Integer32, sonusActiveCallSlotIndex Integer32, sonusActiveCallIndex Integer32, sonusActiveCallId Integer32, sonusActiveCallSonicBusUnitsAllocated Integer32, sonusActiveCallNumResources Integer32, sonusActiveCallState DisplayString, sonusActiveCallIngressServProfile DisplayString, sonusActiveCallEgressServProfile DisplayString, sonusActiveCallCallingNum DisplayString, sonusActiveCallCalledNum DisplayString, sonusActiveCallAddressTransPerformed INTEGER, sonusActiveCallOrigCalledNum DisplayString, sonusActiveCallScenarioType DisplayString, sonusActiveCallIngressPstnSlotNum Integer32, sonusActiveCallIngressPstnPortNum Integer32, sonusActiveCallIngressPstnChannelNum Integer32, sonusActiveCallIngressPstnChannelCount Integer32, sonusActiveCallIngressPstnChannelBitMap Integer32, sonusActiveCallEgressPstnSlotNum Integer32, sonusActiveCallEgressPstnPortNum Integer32, sonusActiveCallEgressPstnChannelNum Integer32, sonusActiveCallEgressPstnChannelCount Integer32, sonusActiveCallEgressPstnChannelBitMap Integer32, sonusActiveCallIngressLocalIpSockAddr IpAddress, sonusActiveCallIngressRemoteIpSockAddr IpAddress, sonusActiveCallEgressLocalIpSockAddr IpAddress, sonusActiveCallEgressRemoteIpSockAddr IpAddress, sonusActiveCallIngressPstnTrunk DisplayString, sonusActiveCallEgressPstnTrunk DisplayString, sonusActiveCallIngressIpDestGwName DisplayString, sonusActiveCallEgressIpDestGwName DisplayString, sonusActiveCallDuration Integer32, sonusActiveCallIngressEpType INTEGER, sonusActiveCallEgressEpType INTEGER, sonusActiveCallIngressSgType INTEGER, sonusActiveCallEgressSgType INTEGER, sonusActiveCallPacketsSent Integer32, sonusActiveCallPacketsReceived Integer32, sonusActiveCallOctetsSent Integer32, sonusActiveCallOctetsReceived Integer32, sonusActiveCallPacketsLost Integer32, sonusActiveCallPacketsDiscarded Integer32, sonusActiveCallInterarrivalJitter Integer32, sonusActiveCallPacketLatency Integer32 } sonusActiveCallShelfIndex OBJECT-TYPE SYNTAX Integer32 (1..6) MAX-ACCESS read-only STATUS current DESCRIPTION "Identifies the target shelf." ::= { sonusActiveCallEntry 1 } sonusActiveCallSlotIndex OBJECT-TYPE SYNTAX Integer32 (1..16) MAX-ACCESS read-only STATUS current DESCRIPTION "Identifies the target slot." ::= { sonusActiveCallEntry 2 } sonusActiveCallIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Identifies the target call index." ::= { sonusActiveCallEntry 3 } sonusActiveCallId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Represents the global call identifier (GCID) for the call. GCID is unique across the entire node." ::= { sonusActiveCallEntry 4 } sonusActiveCallSonicBusUnitsAllocated OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Represents the SonicBus bandwidth allocated for the call expressed as SonicData Units per second." ::= { sonusActiveCallEntry 5 } sonusActiveCallNumResources OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Represents the number of resources currently allocated to the call." ::= { sonusActiveCallEntry 6 } sonusActiveCallState OBJECT-TYPE SYNTAX DisplayString (SIZE(0..23)) MAX-ACCESS read-only STATUS current DESCRIPTION "Represents the current call state." ::= { sonusActiveCallEntry 7 } sonusActiveCallIngressServProfile OBJECT-TYPE SYNTAX DisplayString (SIZE(0..23)) MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the ingress service profile associated with this call." ::= { sonusActiveCallEntry 8 } sonusActiveCallEgressServProfile OBJECT-TYPE SYNTAX DisplayString (SIZE(0..23)) MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the egress service profile associated with this call." ::= { sonusActiveCallEntry 9 } sonusActiveCallCallingNum OBJECT-TYPE SYNTAX DisplayString (SIZE(0..30)) MAX-ACCESS read-only STATUS current DESCRIPTION "The E.164 number representing the Calling Party's telephone number." ::= { sonusActiveCallEntry 10 } sonusActiveCallCalledNum OBJECT-TYPE SYNTAX DisplayString (SIZE(0..30)) MAX-ACCESS read-only STATUS current DESCRIPTION "The E.164 number representing the Called Party's telephone number." ::= { sonusActiveCallEntry 11 } sonusActiveCallAddressTransPerformed OBJECT-TYPE SYNTAX INTEGER { none(1), lnp(2), tollfree(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether any address translation has been performed on the called party number. Valid translations are Local Number Portability (LPN), and 800 number translation (Tollfree)." ::= { sonusActiveCallEntry 12 } sonusActiveCallOrigCalledNum OBJECT-TYPE SYNTAX DisplayString (SIZE(0..30)) MAX-ACCESS read-only STATUS current DESCRIPTION "If an address translation has been performed on the called party number, this entry contains the original, untranslated number." ::= { sonusActiveCallEntry 13 } sonusActiveCallScenarioType OBJECT-TYPE SYNTAX DisplayString (SIZE(0..23)) MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies the call scenario type for this call." ::= { sonusActiveCallEntry 14 } sonusActiveCallIngressPstnSlotNum OBJECT-TYPE SYNTAX Integer32 (1..16) MAX-ACCESS read-only STATUS current DESCRIPTION "For calls originating from the PSTN (circuit) side, indicates the slot of the circuit card on which the call was delivered." ::= { sonusActiveCallEntry 15 } sonusActiveCallIngressPstnPortNum OBJECT-TYPE SYNTAX Integer32 (1..28) MAX-ACCESS read-only STATUS current DESCRIPTION "For calls originating from the PSTN (circuit) side, indicates the T1 port on the circuit card on which the call was delivered. For CNS10 cards, the port number will be in the range 1-12; for CNS30 cards, the port number will be in the range 1-28." ::= { sonusActiveCallEntry 16 } sonusActiveCallIngressPstnChannelNum OBJECT-TYPE SYNTAX Integer32 (1..24) MAX-ACCESS read-only STATUS current DESCRIPTION "For calls originating from the PSTN (circuit) side, indicates the DS0 channel on which the call is being carried." ::= { sonusActiveCallEntry 17 } sonusActiveCallIngressPstnChannelCount OBJECT-TYPE SYNTAX Integer32 (1..24) MAX-ACCESS read-only STATUS current DESCRIPTION "For calls originating from the PSTN (circuit) side, indicates the number of DS0 channels on which the call is being carried. This value is meaningful for Nx64 service calls." ::= { sonusActiveCallEntry 18 } sonusActiveCallIngressPstnChannelBitMap OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "For calls originating from the PSTN (circuit) side, provides a bit map of DS0 channels on which the call is being carried. For Nx64 service calls where N is greater than 1, multiple bits will be marked in the bit map." ::= { sonusActiveCallEntry 19 } sonusActiveCallEgressPstnSlotNum OBJECT-TYPE SYNTAX Integer32 (1..16) MAX-ACCESS read-only STATUS current DESCRIPTION "For calls delivered to the PSTN (circuit) side, indicates the slot of the circuit card on which the call was delivered." ::= { sonusActiveCallEntry 20 } sonusActiveCallEgressPstnPortNum OBJECT-TYPE SYNTAX Integer32 (1..28) MAX-ACCESS read-only STATUS current DESCRIPTION "For calls delivered to the PSTN (circuit) side, indicates the T1 port on the circuit card on which the call was delivered. For CNS10 cards, the port number will be in the range 1-12; for CNS30 cards, the port number will be in the range 1-28." ::= { sonusActiveCallEntry 21 } sonusActiveCallEgressPstnChannelNum OBJECT-TYPE SYNTAX Integer32 (1..24) MAX-ACCESS read-only STATUS current DESCRIPTION "For calls delivered to the PSTN (circuit) side, indicates the DS0 channel on which the call is being carried." ::= { sonusActiveCallEntry 22 } sonusActiveCallEgressPstnChannelCount OBJECT-TYPE SYNTAX Integer32 (1..24) MAX-ACCESS read-only STATUS current DESCRIPTION "For calls delivered to the PSTN (circuit) side, indicates the number of DS0 channels on which the call is being carried. This value is meaningful for Nx64 service calls." ::= { sonusActiveCallEntry 23 } sonusActiveCallEgressPstnChannelBitMap OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "For calls delivered to the PSTN (circuit) side, provides a bit map of DS0 channels on which the call is being carried. For Nx64 service calls where N is greater than 1, multiple bits will be marked in the bit map." ::= { sonusActiveCallEntry 24 } sonusActiveCallIngressLocalIpSockAddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "For calls originated on the IP (packet) side, indicates the IP address of the incoming (ingress) local socket connection." ::= { sonusActiveCallEntry 25 } sonusActiveCallIngressRemoteIpSockAddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "For calls originated on the IP (packet) side, indicates the IP address of the incoming (ingress) remote socket connection." ::= { sonusActiveCallEntry 26 } sonusActiveCallEgressLocalIpSockAddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "For calls delivered to the IP (packet) side, indicates the IP address of the outgoing (egress) local socket connection." ::= { sonusActiveCallEntry 27 } sonusActiveCallEgressRemoteIpSockAddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "For calls delivered to the IP (packet) side, indicates the IP address of the outgoing (egress) remote socket connection." ::= { sonusActiveCallEntry 28 } sonusActiveCallIngressPstnTrunk OBJECT-TYPE SYNTAX DisplayString (SIZE(0..23)) MAX-ACCESS read-only STATUS current DESCRIPTION "For calls originating from the PSTN (circuit) side, specifies the trunk group name to which the Ingress Pstn Channel belongs." ::= { sonusActiveCallEntry 29 } sonusActiveCallEgressPstnTrunk OBJECT-TYPE SYNTAX DisplayString (SIZE(0..23)) MAX-ACCESS read-only STATUS current DESCRIPTION "For calls delivered to the PSTN (circuit) side, specifies the trunk group name to which the Egress Pstn Channel belongs." ::= { sonusActiveCallEntry 30 } sonusActiveCallIngressIpDestGwName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..23)) MAX-ACCESS read-only STATUS current DESCRIPTION "For calls originating from the IP (packet) side, specifies the name of the remote gateway on which the call originated." ::= { sonusActiveCallEntry 31 } sonusActiveCallEgressIpDestGwName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..23)) MAX-ACCESS read-only STATUS current DESCRIPTION "For calls delivered to the IP (packet) side, specifies the name of the remote gateway to which the call was delivered." ::= { sonusActiveCallEntry 32 } sonusActiveCallDuration OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the duration in seconds for this call following answer." ::= { sonusActiveCallEntry 33 } sonusActiveCallIngressEpType OBJECT-TYPE SYNTAX INTEGER { unknown(0), circuit(1), packet(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the end point type for the ingress end point." ::= { sonusActiveCallEntry 34 } sonusActiveCallEgressEpType OBJECT-TYPE SYNTAX INTEGER { unknown(0), circuit(1), packet(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the end point type for the egress end point." ::= { sonusActiveCallEntry 35 } sonusActiveCallIngressSgType OBJECT-TYPE SYNTAX INTEGER { unknown(0), isup(1), cas(2), isdn(3), h323(4), gwip(5), internal1(6), internal2(7), mg(8), asg(9), static(10) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the signaling type for the ingress end point." ::= { sonusActiveCallEntry 36 } sonusActiveCallEgressSgType OBJECT-TYPE SYNTAX INTEGER { unknown(0), isup(1), cas(2), isdn(3), h323(4), gwip(5), internal1(6), internal2(7), mg(8), asg(9), static(10) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the signaling type for the egress end point." ::= { sonusActiveCallEntry 37 } sonusActiveCallPacketsSent OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the number of RTP packets sent on this call." ::= { sonusActiveCallEntry 38 } sonusActiveCallPacketsReceived OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the number of RTP packets received on this call." ::= { sonusActiveCallEntry 39 } sonusActiveCallOctetsSent OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the number of RTP octets sent on this call." ::= { sonusActiveCallEntry 40 } sonusActiveCallOctetsReceived OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the number of RTP octets received on this call." ::= { sonusActiveCallEntry 41 } sonusActiveCallPacketsLost OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the number of RTP packets lost on this call." ::= { sonusActiveCallEntry 42 } sonusActiveCallPacketsDiscarded OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the number of RTP packets discarded by the jitter buffer." ::= { sonusActiveCallEntry 43 } sonusActiveCallInterarrivalJitter OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the interarrival packet jitter on this call." ::= { sonusActiveCallEntry 44 } sonusActiveCallPacketLatency OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the latency experienced on this call." ::= { sonusActiveCallEntry 45 } sonusCallResTable OBJECT-TYPE SYNTAX SEQUENCE OF SonusCallResEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table presents the call resource data for the node. Each active call contains a set of allocated resources. This table provides a brief description and the information required to access detailed information about each allocated resource." ::= { sonusNodeResourcesMIBObjects 4 } sonusCallResEntry OBJECT-TYPE SYNTAX SonusCallResEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { sonusCallResShelfIndex, sonusCallResSlotIndex, sonusCallResCallIndex, sonusCallResIndex } ::= { sonusCallResTable 1 } SonusCallResEntry ::= SEQUENCE { sonusCallResShelfIndex Integer32, sonusCallResSlotIndex Integer32, sonusCallResCallIndex Integer32, sonusCallResIndex Integer32, sonusCallResId Integer32, sonusCallResCallId Integer32, sonusCallResType INTEGER, sonusCallResMgrHandle Integer32, sonusCallResMgrShelfIndex Integer32, sonusCallResMgrSlotIndex Integer32 } sonusCallResShelfIndex OBJECT-TYPE SYNTAX Integer32 (1..6) MAX-ACCESS read-only STATUS current DESCRIPTION "Identifies the target shelf containing the call to be accessed." ::= { sonusCallResEntry 1 } sonusCallResSlotIndex OBJECT-TYPE SYNTAX Integer32 (1..16) MAX-ACCESS read-only STATUS current DESCRIPTION "Identifies the target slot containing the call to be accessed." ::= { sonusCallResEntry 2 } sonusCallResCallIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Identifies the target call to be accessed." ::= { sonusCallResEntry 3 } sonusCallResIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Identifies the target resource index to access within the call." ::= { sonusCallResEntry 4 } sonusCallResId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Represents the internal resource identifier that uniquely represents the resource to the resource manager entity responsible for the resource." ::= { sonusCallResEntry 5 } sonusCallResCallId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Represents the global call identifier (GCID) for the call to which this resource is allocated. This information is provided to ensure that the resource is truly allocated to the call." ::= { sonusCallResEntry 6 } sonusCallResType OBJECT-TYPE SYNTAX INTEGER { bresIcm(0), bresSw2Nif(1), bresSw2DspCtrl(2), bresSw2DspLocal(3), bresSw2DspSonic(4), bresDsp2Dsp(5), bresDsp2Sonic(6), bresLe2Sonic(7), bresAtm2Sw(8), bresSw2Atm(9), dresPstn(10), dresService(11), pres(12), xresCntrl(13), xresUser(14), aresAmq2Dsp(15), atmres(16), bresSw2DspApps(17) } MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies the resource type for this resource." ::= { sonusCallResEntry 7 } sonusCallResMgrHandle OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies the internal handle for the resource manager entity responsible for this resource. This element is provided for information only." ::= { sonusCallResEntry 8 } sonusCallResMgrShelfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies the shelf on which this resource resides." ::= { sonusCallResEntry 9 } sonusCallResMgrSlotIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies the card slot on which this resource resides." ::= { sonusCallResEntry 10 } sonusCallPegCountsTable OBJECT-TYPE SYNTAX SEQUENCE OF SonusCallPegCountsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table presents call peg count statistics for the node." ::= { sonusNodeResourcesMIBObjects 5 } sonusCallPegCountsEntry OBJECT-TYPE SYNTAX SonusCallPegCountsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { sonusCallPegCountsShelfIndex, sonusCallPegCountsSlotIndex } ::= { sonusCallPegCountsTable 1 } SonusCallPegCountsEntry ::= SEQUENCE { sonusCallPegCountsShelfIndex Integer32, sonusCallPegCountsSlotIndex Integer32, sonusCallPegCountsReset INTEGER, sonusCallPegCountsAttempts Integer32, sonusCallPegCountsCompletions Integer32, sonusCallPegCountsActiveCalls Integer32, sonusCallPegCountsStableCalls Integer32, sonusCallPegCountsUpdates Integer32, sonusCallPegCountsActiveCallsNonUser Integer32, sonusCallPegCountsStableCallsNonUser Integer32 } sonusCallPegCountsShelfIndex OBJECT-TYPE SYNTAX Integer32 (1..6) MAX-ACCESS read-only STATUS current DESCRIPTION "Identifies the target shelf to obtain the call counters." ::= { sonusCallPegCountsEntry 1 } sonusCallPegCountsSlotIndex OBJECT-TYPE SYNTAX Integer32 (1..16) MAX-ACCESS read-only STATUS current DESCRIPTION "Identifies the target slot." ::= { sonusCallPegCountsEntry 2 } sonusCallPegCountsReset OBJECT-TYPE SYNTAX INTEGER { unknown(1), reset(2) } MAX-ACCESS read-create STATUS current DESCRIPTION "Provides a means to reset the active call attempt and completion counters. Any set operation on this object will result in the attempt and completion counters being cleared." ::= { sonusCallPegCountsEntry 3 } sonusCallPegCountsAttempts OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the number of call attempts on this shelf." ::= { sonusCallPegCountsEntry 4 } sonusCallPegCountsCompletions OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the total number of completed call attempts on this shelf." ::= { sonusCallPegCountsEntry 5 } sonusCallPegCountsActiveCalls OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the current number of active calls in the shelf." ::= { sonusCallPegCountsEntry 6 } sonusCallPegCountsStableCalls OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the current number of stable calls in the shelf." ::= { sonusCallPegCountsEntry 7 } sonusCallPegCountsUpdates OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the number of call updates (modifications) on this shelf." ::= { sonusCallPegCountsEntry 8 } sonusCallPegCountsActiveCallsNonUser OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the current number of active non-call associated signalling channels in the shelf. (ie ISDN D channel)" ::= { sonusCallPegCountsEntry 9 } sonusCallPegCountsStableCallsNonUser OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the current number of stable non-call associated signalling channels in the shelf. (ie ISDN D channel)" ::= { sonusCallPegCountsEntry 10 } sonusToneObjects OBJECT IDENTIFIER ::= { sonusNodeResourcesMIBObjects 6 } sonusToneProfile OBJECT IDENTIFIER ::= { sonusToneObjects 1 } sonusToneProfileNextIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The next valid index to use when creating an entry in the sonusToneProfileTable." ::= { sonusToneProfile 1 } sonusToneProfileTable OBJECT-TYPE SYNTAX SEQUENCE OF SonusToneProfileEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains tone profiles for the node." ::= { sonusToneProfile 2 } sonusToneProfileEntry OBJECT-TYPE SYNTAX SonusToneProfileEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { sonusToneProfileIndex } ::= { sonusToneProfileTable 1 } SonusToneProfileEntry ::= SEQUENCE { sonusToneProfileIndex Integer32, sonusToneProfileName SonusName, sonusToneProfileGenerationMethod INTEGER, sonusToneProfileTone1Freq Integer32, sonusToneProfileTone1Power Integer32, sonusToneProfileTone2Freq Integer32, sonusToneProfileTone2Power Integer32, sonusToneProfileCarrierFreq Integer32, sonusToneProfileSignalFreq Integer32, sonusToneProfileModPower Integer32, sonusToneProfileModIndex Integer32, sonusToneProfileMake1 Integer32, sonusToneProfileBreak1 Integer32, sonusToneProfileMake2 Integer32, sonusToneProfileBreak2 Integer32, sonusToneProfileMake3 Integer32, sonusToneProfileBreak3 Integer32, sonusToneProfileRepeat Integer32, sonusToneProfileRowStatus RowStatus } sonusToneProfileIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Identifies the tone profile entry." ::= { sonusToneProfileEntry 1 } sonusToneProfileName OBJECT-TYPE SYNTAX SonusName MAX-ACCESS read-write STATUS current DESCRIPTION "The user name of this tone profile." ::= { sonusToneProfileEntry 2 } sonusToneProfileGenerationMethod OBJECT-TYPE SYNTAX INTEGER { singleTone(1), dualTone(2), modulatedTone(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Determines the generation method for the tone. This value is specified at object creation time and cannot be modified." ::= { sonusToneProfileEntry 3 } sonusToneProfileTone1Freq OBJECT-TYPE SYNTAX Integer32 (0..3999) MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies Tone 1 Frequency in Hertz. If 0, then silence is generated. Only valid if generation method is singleTone or dualTone." DEFVAL { 0 } ::= { sonusToneProfileEntry 4 } sonusToneProfileTone1Power OBJECT-TYPE SYNTAX Integer32 (-50..3) MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies Tone 1 Power in dBm. Power levels range from -50 dBm (minimum power) to +3 dBm (maximum power). Only valid if generation method is singleTone or dualTone." DEFVAL { 0 } ::= { sonusToneProfileEntry 5 } sonusToneProfileTone2Freq OBJECT-TYPE SYNTAX Integer32 (0..3999) MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies Tone 2 Frequency in Hertz. If 0, then a single frequency tone is generated. Only valid if generation method is dualTone." DEFVAL { 0 } ::= { sonusToneProfileEntry 6 } sonusToneProfileTone2Power OBJECT-TYPE SYNTAX Integer32 (-50..3) MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies Tone 2 Power in dBm. Power levels range from -50 dBm (minimum power) to +3 dBm (maximum power). Only valid if generation method is dualTone." DEFVAL { 0 } ::= { sonusToneProfileEntry 7 } sonusToneProfileCarrierFreq OBJECT-TYPE SYNTAX Integer32 (0..3999) MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies the frequency in Hertz of the carrier for the modulated signal. Value must be less than 4000. If set to 0, then silence is generated. Only valid if generation method is modulatedTone." DEFVAL { 0 } ::= { sonusToneProfileEntry 8 } sonusToneProfileSignalFreq OBJECT-TYPE SYNTAX Integer32 (0..3999) MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies the frequency in Hertz of the sinusoid modulating the carrier sinusoid. Value must be less than 4000. Only valid if generation method is modulatedTone." DEFVAL { 0 } ::= { sonusToneProfileEntry 9 } sonusToneProfileModPower OBJECT-TYPE SYNTAX Integer32 (-50..3) MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies Carrier Power in dBm. Power levels range from -50 dBm (minimum power) to +3 dBm (maximum power). Only valid if generation method is modulatedTone." DEFVAL { 0 } ::= { sonusToneProfileEntry 10 } sonusToneProfileModIndex OBJECT-TYPE SYNTAX Integer32 (0..300) MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies the modulation index of the signal. Value must be in the range of 0 to 300 in 1% units. Only valid if generation method is modulatedTone." DEFVAL { 0 } ::= { sonusToneProfileEntry 11 } sonusToneProfileMake1 OBJECT-TYPE SYNTAX Integer32 (-1..8000) MAX-ACCESS read-write STATUS current DESCRIPTION "Duration of the first on cadence in milliseconds. If 0, then the duration of the first on cadence is 0 msec. If -1, then the tone is played continuously." DEFVAL { 0 } ::= { sonusToneProfileEntry 12 } sonusToneProfileBreak1 OBJECT-TYPE SYNTAX Integer32 (-1..8000) MAX-ACCESS read-write STATUS current DESCRIPTION "Duration of the first off cadence in milliseconds. If 0, then silence is not generated between the on cadences. If -1, then silence is generated continuously." DEFVAL { 0 } ::= { sonusToneProfileEntry 13 } sonusToneProfileMake2 OBJECT-TYPE SYNTAX Integer32 (-1..8000) MAX-ACCESS read-write STATUS current DESCRIPTION "Duration of the second on cadence in milliseconds. If 0, then the duration of the second on cadence is 0 msec. If -1, then the tone is played continuously." DEFVAL { 0 } ::= { sonusToneProfileEntry 14 } sonusToneProfileBreak2 OBJECT-TYPE SYNTAX Integer32 (-1..8000) MAX-ACCESS read-write STATUS current DESCRIPTION "Duration of the second off cadence in milliseconds. If 0, then silence is not generated between the on cadences. If -1, then silence is generated continuously." DEFVAL { 0 } ::= { sonusToneProfileEntry 15 } sonusToneProfileMake3 OBJECT-TYPE SYNTAX Integer32 (-1..8000) MAX-ACCESS read-write STATUS current DESCRIPTION "Duration of the thrid on cadence in milliseconds. If 0, then the duration of the third on cadence is 0 msec. If -1, then the tone is played continuously." DEFVAL { 0 } ::= { sonusToneProfileEntry 16 } sonusToneProfileBreak3 OBJECT-TYPE SYNTAX Integer32 (-1..8000) MAX-ACCESS read-write STATUS current DESCRIPTION "Duration of the third off cadence in milliseconds. If 0, then silence is not generated after the third on cadence. If -1, then silence is generated continuously." DEFVAL { 0 } ::= { sonusToneProfileEntry 17 } sonusToneProfileRepeat OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Number of cadence cycles to generate. If 0, then the tone pattern is repeated indefinitely." DEFVAL { 1 } ::= { sonusToneProfileEntry 18 } sonusToneProfileRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-write STATUS current DESCRIPTION "" ::= { sonusToneProfileEntry 19 } sonusToneType OBJECT IDENTIFIER ::= { sonusToneObjects 2 } sonusToneTypeNextIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The next valid index to use when creating an entry in the sonusToneTypeTable." ::= { sonusToneType 1 } sonusToneTypeTable OBJECT-TYPE SYNTAX SEQUENCE OF SonusToneTypeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains tone types for the node." ::= { sonusToneType 2 } sonusToneTypeEntry OBJECT-TYPE SYNTAX SonusToneTypeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { sonusToneTypeIndex } ::= { sonusToneTypeTable 1 } SonusToneTypeEntry ::= SEQUENCE { sonusToneTypeIndex Integer32, sonusToneTypeName SonusName, sonusToneTypeRowStatus RowStatus } sonusToneTypeIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Identifies the tone type entry." ::= { sonusToneTypeEntry 1 } sonusToneTypeName OBJECT-TYPE SYNTAX SonusName MAX-ACCESS read-write STATUS current DESCRIPTION "The user name of this tone type. Possible types include 'dial', 'busy', 'reorder', etc." ::= { sonusToneTypeEntry 2 } sonusToneTypeRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-write STATUS current DESCRIPTION "" ::= { sonusToneTypeEntry 3 } sonusTonePackage OBJECT IDENTIFIER ::= { sonusToneObjects 3 } sonusTonePackageNextIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The next valid index to use when creating an entry in the sonusTonePackageTable." ::= { sonusTonePackage 1 } sonusTonePackageTable OBJECT-TYPE SYNTAX SEQUENCE OF SonusTonePackageEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains tone packages for the node." ::= { sonusTonePackage 2 } sonusTonePackageEntry OBJECT-TYPE SYNTAX SonusTonePackageEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { sonusTonePackageIndex } ::= { sonusTonePackageTable 1 } SonusTonePackageEntry ::= SEQUENCE { sonusTonePackageIndex Integer32, sonusTonePackageName SonusName, sonusTonePackageRowStatus RowStatus } sonusTonePackageIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Identifies the tone package." ::= { sonusTonePackageEntry 1 } sonusTonePackageName OBJECT-TYPE SYNTAX SonusName MAX-ACCESS read-write STATUS current DESCRIPTION "The name of this tone package. This name should reflect the country or carrier which will be using this package." ::= { sonusTonePackageEntry 2 } sonusTonePackageRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-write STATUS current DESCRIPTION "" ::= { sonusTonePackageEntry 3 } sonusTonePkgElem OBJECT IDENTIFIER ::= { sonusToneObjects 4 } sonusTonePkgElemTable OBJECT-TYPE SYNTAX SEQUENCE OF SonusTonePkgElemEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains elements which bind tone types to tone profiles for a given tone package." ::= { sonusTonePkgElem 1 } sonusTonePkgElemEntry OBJECT-TYPE SYNTAX SonusTonePkgElemEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { sonusTonePkgElemIndex } ::= { sonusTonePkgElemTable 1 } SonusTonePkgElemEntry ::= SEQUENCE { sonusTonePkgElemIndex Integer32, sonusTonePkgElemTonePackageRef SonusNameReference, sonusTonePkgElemToneTypeRef SonusNameReference, sonusTonePkgElemToneProfileRef SonusNameReference, sonusTonePkgElemRowStatus RowStatus } sonusTonePkgElemIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Identifies the target tone package element." ::= { sonusTonePkgElemEntry 1 } sonusTonePkgElemTonePackageRef OBJECT-TYPE SYNTAX SonusNameReference MAX-ACCESS read-write STATUS current DESCRIPTION "Identifies the tone packge for this element." ::= { sonusTonePkgElemEntry 2 } sonusTonePkgElemToneTypeRef OBJECT-TYPE SYNTAX SonusNameReference MAX-ACCESS read-write STATUS current DESCRIPTION "Identifies the tone type for this element." ::= { sonusTonePkgElemEntry 3 } sonusTonePkgElemToneProfileRef OBJECT-TYPE SYNTAX SonusNameReference MAX-ACCESS read-write STATUS current DESCRIPTION "The name of the tone profile that this tone type maps to for this tone package." DEFVAL { "default" } ::= { sonusTonePkgElemEntry 4 } sonusTonePkgElemRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-write STATUS current DESCRIPTION "" ::= { sonusTonePkgElemEntry 5 } sonusDigitProfile OBJECT IDENTIFIER ::= { sonusNodeResourcesMIBObjects 7 } sonusDigitProfileNextIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The next valid index to use when creating an entry in the sonusDigitProfileTable." ::= { sonusDigitProfile 1 } sonusDigitProfileTable OBJECT-TYPE SYNTAX SEQUENCE OF SonusDigitProfileEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains digit profiles for the node. Digit Profiles contain both digit generation (sonusDigitProfileGen...) and digit detection (sonusDigitProfileDet...) parameters." ::= { sonusDigitProfile 2 } sonusDigitProfileEntry OBJECT-TYPE SYNTAX SonusDigitProfileEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { sonusDigitProfileIndex } ::= { sonusDigitProfileTable 1 } SonusDigitProfileEntry ::= SEQUENCE { sonusDigitProfileIndex Integer32, sonusDigitProfileName SonusName, sonusDigitProfileType INTEGER, sonusDigitProfileGenPower Integer32, sonusDigitProfileGenMake Integer32, sonusDigitProfileGenBreak Integer32, sonusDigitProfileDetMinPower Integer32, sonusDigitProfileDetMinOnDuration Integer32, sonusDigitProfileDetMinOffDuration Integer32, sonusDigitProfileDetFreqAcceptRange INTEGER, sonusDigitProfileDtmfDetTwistCutoff Integer32, sonusDigitProfileMfr1GenMakeKp Integer32, sonusDigitProfileRowStatus RowStatus } sonusDigitProfileIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Identifies the digit profile entry." ::= { sonusDigitProfileEntry 1 } sonusDigitProfileName OBJECT-TYPE SYNTAX SonusName MAX-ACCESS read-write STATUS current DESCRIPTION "The user name of this digit profile." ::= { sonusDigitProfileEntry 2 } sonusDigitProfileType OBJECT-TYPE SYNTAX INTEGER { dtmf(1), mfr1(2), mfr2f(3), mfr2b(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies the digit's format. This value is set at object creation time and cannot be modified." ::= { sonusDigitProfileEntry 3 } sonusDigitProfileGenPower OBJECT-TYPE SYNTAX Integer32 (-50..3) MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies digit generation power level in dBm. Power level ranges from -50 dBm (minimum power) to +3 dBm (maximum power)." DEFVAL { -10 } ::= { sonusDigitProfileEntry 4 } sonusDigitProfileGenMake OBJECT-TYPE SYNTAX Integer32 (0..8000) MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies duration of generated digits in milliseconds." DEFVAL { 100 } ::= { sonusDigitProfileEntry 5 } sonusDigitProfileGenBreak OBJECT-TYPE SYNTAX Integer32 (0..8000) MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies silence between generated digits in milliseconds." DEFVAL { 100 } ::= { sonusDigitProfileEntry 6 } sonusDigitProfileDetMinPower OBJECT-TYPE SYNTAX Integer32 (-45..-25) MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies minimum power level in dBm required for digit detection. Valid levels range from -45dBm to -25dBm." DEFVAL { -45 } ::= { sonusDigitProfileEntry 7 } sonusDigitProfileDetMinOnDuration OBJECT-TYPE SYNTAX Integer32 (25..100) MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies minimum tone duration in milliseconds required for digit detection. The value must in increments of 5ms. For DTMF digits, the value must be between 25ms and 80ms. For MF digits, the value must be between 25ms and 100ms." DEFVAL { 40 } ::= { sonusDigitProfileEntry 8 } sonusDigitProfileDetMinOffDuration OBJECT-TYPE SYNTAX Integer32 (10..100) MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies minimum interdigit duration in milliseconds for digit detection. The value must be in increments of 5ms. For DTMF digits, the value must be between 25ms and 80ms. For MF digits, the value must be between 10ms and 100ms. " DEFVAL { 40 } ::= { sonusDigitProfileEntry 9 } sonusDigitProfileDetFreqAcceptRange OBJECT-TYPE SYNTAX INTEGER { narrow(1), medium(2), wide(3), wider(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies frequency tolerances for digit detection. For DTMF digits the value represents accept and reject ranges. For MF digits the value represents only the accept range. Frequencies detected within the accept range will result in digit detection. Frequencies detected outside the reject range will not result in digit detection. . DTMF DTMF MFR1 VALUE ENUMERATION ACCEPT REJECT ACCEPT ----- ----------- ---------------- ------------------ 1 narrow +/-2.0% +/-3.0% +/-(1.5% + 5Hz) 2 medium +/-2.5% +/-3.5% +/-(1.5% + 10Hz) 3 wide +/-3.0% +/-4.0% +/-(1.5% + 15Hz) 4 wider +/-3.5% +/-4.5% N/A" DEFVAL { 2 } ::= { sonusDigitProfileEntry 10 } sonusDigitProfileDtmfDetTwistCutoff OBJECT-TYPE SYNTAX Integer32 (4..12) MAX-ACCESS read-write STATUS current DESCRIPTION "For DTMF digit detection only. Twist is the ratio of high group power to low. Twist ratios below the twist cutoff will result in digit detection. Twist ratios above the twist cutoff will result in digit rejection. Value must be between 4dB and 12dB in increments of 2dB." DEFVAL { 8 } ::= { sonusDigitProfileEntry 11 } sonusDigitProfileMfr1GenMakeKp OBJECT-TYPE SYNTAX Integer32 (0..8000) MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies duration of generated KP digit in milliseconds. Only applicable if digit type is MFR1." DEFVAL { 105 } ::= { sonusDigitProfileEntry 12 } sonusDigitProfileRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-write STATUS current DESCRIPTION "" ::= { sonusDigitProfileEntry 13 } sonusStaticCall OBJECT IDENTIFIER ::= { sonusNodeResourcesMIBObjects 8 } sonusStaticCallNextIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The next valid index to use when creating an entry in the sonusStaticCallAdmnTable" ::= { sonusStaticCall 1 } sonusStaticCallAdmnTable OBJECT-TYPE SYNTAX SEQUENCE OF SonusStaticCallAdmnEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table specifies the static call list for the node." ::= { sonusStaticCall 2 } sonusStaticCallAdmnEntry OBJECT-TYPE SYNTAX SonusStaticCallAdmnEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { sonusStaticCallAdmnIndex } ::= { sonusStaticCallAdmnTable 1 } SonusStaticCallAdmnEntry ::= SEQUENCE { sonusStaticCallAdmnIndex Integer32, sonusStaticCallAdmnState INTEGER, sonusStaticCallAdmnName SonusName, sonusStaticCallAdmnEndPointAShelf Integer32, sonusStaticCallAdmnEndPointASlot Integer32, sonusStaticCallAdmnEndPointAPort Integer32, sonusStaticCallAdmnEndPointAChannel Integer32, sonusStaticCallAdmnEndPointAServProfile SonusName, sonusStaticCallAdmnEndPointBType INTEGER, sonusStaticCallAdmnEndPointBShelf Integer32, sonusStaticCallAdmnEndPointBSlot Integer32, sonusStaticCallAdmnEndPointBPort Integer32, sonusStaticCallAdmnEndPointBChannel Integer32, sonusStaticCallAdmnEndPointBLocalRTPPort Integer32, sonusStaticCallAdmnEndPointBLocalIpAddress IpAddress, sonusStaticCallAdmnEndPointBRemoteRTPPort Integer32, sonusStaticCallAdmnEndPointBRemoteIpAddress IpAddress, sonusStaticCallAdmnEndPointBServProfile SonusName, sonusStaticCallAdmnCircuitMode INTEGER, sonusStaticCallAdmnRowStatus RowStatus } sonusStaticCallAdmnIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Identifies the target static call entry." ::= { sonusStaticCallAdmnEntry 1 } sonusStaticCallAdmnState OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabled(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The administrative state of this static call entry." DEFVAL { disabled } ::= { sonusStaticCallAdmnEntry 2 } sonusStaticCallAdmnName OBJECT-TYPE SYNTAX SonusName MAX-ACCESS read-write STATUS current DESCRIPTION "The user name of this static call." ::= { sonusStaticCallAdmnEntry 3 } sonusStaticCallAdmnEndPointAShelf OBJECT-TYPE SYNTAX Integer32 (1..6) MAX-ACCESS read-write STATUS current DESCRIPTION "A 32-bit integer identifying the shelf of the end point A" ::= { sonusStaticCallAdmnEntry 4 } sonusStaticCallAdmnEndPointASlot OBJECT-TYPE SYNTAX Integer32 (1..16) MAX-ACCESS read-write STATUS current DESCRIPTION "A 32-bit integer identifying the slot of the end point A" ::= { sonusStaticCallAdmnEntry 5 } sonusStaticCallAdmnEndPointAPort OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "Port index of end point A." ::= { sonusStaticCallAdmnEntry 6 } sonusStaticCallAdmnEndPointAChannel OBJECT-TYPE SYNTAX Integer32 (1..32) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the DS0 channel of the end point A" ::= { sonusStaticCallAdmnEntry 7 } sonusStaticCallAdmnEndPointAServProfile OBJECT-TYPE SYNTAX SonusName MAX-ACCESS read-write STATUS current DESCRIPTION "The service profile used for end point A" ::= { sonusStaticCallAdmnEntry 8 } sonusStaticCallAdmnEndPointBType OBJECT-TYPE SYNTAX INTEGER { circuit(1), packet(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The type of end point B (circuit or packet)." DEFVAL { circuit } ::= { sonusStaticCallAdmnEntry 9 } sonusStaticCallAdmnEndPointBShelf OBJECT-TYPE SYNTAX Integer32 (1..6) MAX-ACCESS read-write STATUS current DESCRIPTION "A 32-bit integer identifying the shelf of the end point B" ::= { sonusStaticCallAdmnEntry 10 } sonusStaticCallAdmnEndPointBSlot OBJECT-TYPE SYNTAX Integer32 (1..16) MAX-ACCESS read-write STATUS current DESCRIPTION "A 32-bit integer identifying the slot of the end point B" ::= { sonusStaticCallAdmnEntry 11 } sonusStaticCallAdmnEndPointBPort OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "Port index of end point B." ::= { sonusStaticCallAdmnEntry 12 } sonusStaticCallAdmnEndPointBChannel OBJECT-TYPE SYNTAX Integer32 (1..32) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the DS0 channel of the end point B" ::= { sonusStaticCallAdmnEntry 13 } sonusStaticCallAdmnEndPointBLocalRTPPort OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the local RTP port." ::= { sonusStaticCallAdmnEntry 14 } sonusStaticCallAdmnEndPointBLocalIpAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The IP Address of the end point B if it is packet" ::= { sonusStaticCallAdmnEntry 15 } sonusStaticCallAdmnEndPointBRemoteRTPPort OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the remote RTP port." ::= { sonusStaticCallAdmnEntry 16 } sonusStaticCallAdmnEndPointBRemoteIpAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The IP Address of the end point B if it is packet" ::= { sonusStaticCallAdmnEntry 17 } sonusStaticCallAdmnEndPointBServProfile OBJECT-TYPE SYNTAX SonusName MAX-ACCESS read-write STATUS current DESCRIPTION "The service profile used for end point B" ::= { sonusStaticCallAdmnEntry 18 } sonusStaticCallAdmnCircuitMode OBJECT-TYPE SYNTAX INTEGER { voice(1), data(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The circuit mode for this static call" DEFVAL { voice } ::= { sonusStaticCallAdmnEntry 19 } sonusStaticCallAdmnRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-write STATUS current DESCRIPTION "" ::= { sonusStaticCallAdmnEntry 20 } sonusStaticCallStatTable OBJECT-TYPE SYNTAX SEQUENCE OF SonusStaticCallStatEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Manual Call Stat Table" ::= { sonusNodeResourcesMIBObjects 9 } sonusStaticCallStatEntry OBJECT-TYPE SYNTAX SonusStaticCallStatEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the Manual Call Stat Table" INDEX { sonusStaticCallStatIndex } ::= { sonusStaticCallStatTable 1 } SonusStaticCallStatEntry ::= SEQUENCE { sonusStaticCallStatIndex Integer32, sonusStaticCallStatCallId Integer32, sonusStaticCallStatState DisplayString, sonusStaticCallStatTime DisplayString } sonusStaticCallStatIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index for target static call." ::= { sonusStaticCallStatEntry 1 } sonusStaticCallStatCallId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The call identifier(GCID) assigned to this static call" ::= { sonusStaticCallStatEntry 2 } sonusStaticCallStatState OBJECT-TYPE SYNTAX DisplayString (SIZE(0..23)) MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the static call" ::= { sonusStaticCallStatEntry 3 } sonusStaticCallStatTime OBJECT-TYPE SYNTAX DisplayString (SIZE(0..23)) MAX-ACCESS read-only STATUS current DESCRIPTION "Displays the Date/time the connection was created" ::= { sonusStaticCallStatEntry 4 } sonusStaticCallActionObjects OBJECT IDENTIFIER ::= { sonusNodeResourcesMIBObjects 10 } sonusStaticCallGcid OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The call identifier for a call to be deleted" ::= { sonusStaticCallActionObjects 1 } sonusStaticCallAction OBJECT-TYPE SYNTAX INTEGER { none(1), delete(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The action that should be taken on the call" DEFVAL { none } ::= { sonusStaticCallActionObjects 2 } sonusCallTrace OBJECT IDENTIFIER ::= { sonusNodeResourcesMIBObjects 11 } sonusCallTraceNextIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The next valid index to use when creating an entry in the sonusCallTraceTable." ::= { sonusCallTrace 1 } sonusCallTraceTable OBJECT-TYPE SYNTAX SEQUENCE OF SonusCallTraceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table specifies the Call Trace Table" ::= { sonusCallTrace 2 } sonusCallTraceEntry OBJECT-TYPE SYNTAX SonusCallTraceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { sonusCallTraceIndex } ::= { sonusCallTraceTable 1 } SonusCallTraceEntry ::= SEQUENCE { sonusCallTraceIndex Integer32, sonusCallTraceState INTEGER, sonusCallTraceName SonusName, sonusCallTraceType INTEGER, sonusCallTraceCalledNumber DisplayString, sonusCallTraceCallingNumber DisplayString, sonusCallTraceLevel INTEGER, sonusCallTraceRowStatus RowStatus } sonusCallTraceIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of this Call Trace entry." ::= { sonusCallTraceEntry 1 } sonusCallTraceState OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabled(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The administrative state of this Call Trace entry." DEFVAL { disabled } ::= { sonusCallTraceEntry 2 } sonusCallTraceName OBJECT-TYPE SYNTAX SonusName MAX-ACCESS read-write STATUS current DESCRIPTION "The name of this Call Trace entry." ::= { sonusCallTraceEntry 3 } sonusCallTraceType OBJECT-TYPE SYNTAX INTEGER { calledcalling(1), calledonly(2), callingonly(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The trace type of this Call Trace entry." DEFVAL { calledcalling } ::= { sonusCallTraceEntry 4 } sonusCallTraceCalledNumber OBJECT-TYPE SYNTAX DisplayString (SIZE(0..30)) MAX-ACCESS read-write STATUS current DESCRIPTION "The called number being traced." ::= { sonusCallTraceEntry 5 } sonusCallTraceCallingNumber OBJECT-TYPE SYNTAX DisplayString (SIZE(0..30)) MAX-ACCESS read-write STATUS current DESCRIPTION "The calling number being traced." ::= { sonusCallTraceEntry 6 } sonusCallTraceLevel OBJECT-TYPE SYNTAX INTEGER { level1(1), level2(2), level3(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The trace level of this call trace entry, currently only one level is supported." DEFVAL { level2 } ::= { sonusCallTraceEntry 7 } sonusCallTraceRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-write STATUS current DESCRIPTION "" ::= { sonusCallTraceEntry 8 } sonusCktServProfile OBJECT IDENTIFIER ::= { sonusNodeResourcesMIBObjects 12 } sonusCktServProfileNextIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The next valid index to use when creating an entry in the sonusCktServProfileTable." ::= { sonusCktServProfile 1 } sonusCktServProfileTable OBJECT-TYPE SYNTAX SEQUENCE OF SonusCktServProfileEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table specifies the Circuit service profile list for the node." ::= { sonusCktServProfile 2 } sonusCktServProfileEntry OBJECT-TYPE SYNTAX SonusCktServProfileEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { sonusCktServProfileIndex } ::= { sonusCktServProfileTable 1 } SonusCktServProfileEntry ::= SEQUENCE { sonusCktServProfileIndex Integer32, sonusCktServProfileState INTEGER, sonusCktServProfileName SonusName, sonusCktServProfileAudioEncoding INTEGER, sonusCktServProfileBandwidth Integer32, sonusCktServProfileNecEnable INTEGER, sonusCktServProfileCttTestType INTEGER, sonusCktServProfileCttTimeout Integer32, sonusCktServProfileCttMinDetectTime Integer32, sonusCktServProfileCttMinReleaseTime Integer32, sonusCktServProfileCapability INTEGER, sonusCktServProfileDataRestrictedCfg INTEGER, sonusCktServProfileDtmfProfileName SonusNameReference, sonusCktServProfileRowStatus RowStatus, sonusCktServProfileInterworkingXfrCap INTEGER } sonusCktServProfileIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Identifies the target circuit service profile entry." ::= { sonusCktServProfileEntry 1 } sonusCktServProfileState OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabled(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The administrative state of this circuit service profile entry." DEFVAL { disabled } ::= { sonusCktServProfileEntry 2 } sonusCktServProfileName OBJECT-TYPE SYNTAX SonusName MAX-ACCESS read-write STATUS current DESCRIPTION "The name of this circuit service profile." ::= { sonusCktServProfileEntry 3 } sonusCktServProfileAudioEncoding OBJECT-TYPE SYNTAX INTEGER { g711ulaw(1), g711alaw(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The audio encoding method to be performed on the voice data received from, and destined to the PSTN. The default encoding method is G.711 Ulaw." DEFVAL { g711ulaw } ::= { sonusCktServProfileEntry 4 } sonusCktServProfileBandwidth OBJECT-TYPE SYNTAX Integer32 (1..24) MAX-ACCESS read-write STATUS current DESCRIPTION "The number of DS0 channels to group for Nx64 connections. Valid entries are 1 to 24 channels, allowing up to a complete set of T1 channels to be grouped at a single connection. The default bandwidth is 1 channel." DEFVAL { 1 } ::= { sonusCktServProfileEntry 5 } sonusCktServProfileNecEnable OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabled(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies whether Network Echo Cancellation (NEC) is enabled for the channel. When enabled, NEC is enabled acording to the appropriate NEC configuration parameters. When disabled, the echo chaceller is bypassed." DEFVAL { enabled } ::= { sonusCktServProfileEntry 6 } sonusCktServProfileCttTestType OBJECT-TYPE SYNTAX INTEGER { remoteLoopback(1), remote2Wire(2), remote4Wire(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "For ISUP service profiles, specifies the type of continuity test to perform, based on the configuration of the remote switch or trunk connection. The remoteLoopback test is used when the remote switch will loop back channel being tested. The remote2Wire test is used when the remote switch supports the 2 wire continuity test procedure. And the remote4Wire test mode is used when the remote switch supports the 4 wire continuity test procedure. The default value is remoteLoopback." DEFVAL { remoteLoopback } ::= { sonusCktServProfileEntry 7 } sonusCktServProfileCttTimeout OBJECT-TYPE SYNTAX Integer32 (1..8) MAX-ACCESS read-write STATUS current DESCRIPTION "For ISUP service profiles, specifies the overall test timeout value. The continuity test will be declared failed if the continuity tone is not detected within this timeout period. The timeout is specified in seconds, with a default value of 2 seconds." DEFVAL { 2 } ::= { sonusCktServProfileEntry 8 } sonusCktServProfileCttMinDetectTime OBJECT-TYPE SYNTAX Integer32 (10..60) MAX-ACCESS read-write STATUS current DESCRIPTION "For ISUP service profiles, specifies the minimum time to detect the presence of the continuity test tone. The minimum detect time is specified in milliseconds, with a default time of 45 ms." DEFVAL { 45 } ::= { sonusCktServProfileEntry 9 } sonusCktServProfileCttMinReleaseTime OBJECT-TYPE SYNTAX Integer32 (10..40) MAX-ACCESS read-write STATUS current DESCRIPTION "For ISUP service profiles, specifies the minimum time to detect that the continuity test tone has been removed and is no longer present. The minimum release time is specified in milliseconds, with a default time of 25 ms." DEFVAL { 25 } ::= { sonusCktServProfileEntry 10 } sonusCktServProfileCapability OBJECT-TYPE SYNTAX INTEGER { voiceOnly(1), circuitModeData(2), voiceOrCircuitModeData(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies the data capabilities for the circuit. This parameter specifies whether voice only, circuit mode data only, or both voice and circuit mode data can be supported by the circuit." DEFVAL { voiceOrCircuitModeData } ::= { sonusCktServProfileEntry 11 } sonusCktServProfileDataRestrictedCfg OBJECT-TYPE SYNTAX INTEGER { unrestricted(1), restricted(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies whether the circuit may support 64 Kbit/s unrestricted data, or if the circuit supports 56 Kbit/s restricted data." DEFVAL { unrestricted } ::= { sonusCktServProfileEntry 12 } sonusCktServProfileDtmfProfileName OBJECT-TYPE SYNTAX SonusNameReference MAX-ACCESS read-write STATUS current DESCRIPTION "The name of DTMF profile associated with this circuit service profile." ::= { sonusCktServProfileEntry 13 } sonusCktServProfileRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-write STATUS current DESCRIPTION "" ::= { sonusCktServProfileEntry 14 } sonusCktServProfileInterworkingXfrCap OBJECT-TYPE SYNTAX INTEGER { speech(1), audio31Khz(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The transfer capability for audio calls when interworking with CAS. The default transfer capability is speech." DEFVAL { speech } ::= { sonusCktServProfileEntry 15 } sonusPktServProfile OBJECT IDENTIFIER ::= { sonusNodeResourcesMIBObjects 13 } sonusPktServProfileNextIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The next valid index to use when creating an entry in the sonusPktServProfileTable." ::= { sonusPktServProfile 1 } sonusPktServProfileTable OBJECT-TYPE SYNTAX SEQUENCE OF SonusPktServProfileEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table specifies the packet service profile list for the node." ::= { sonusPktServProfile 2 } sonusPktServProfileEntry OBJECT-TYPE SYNTAX SonusPktServProfileEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { sonusPktServProfileIndex } ::= { sonusPktServProfileTable 1 } SonusPktServProfileEntry ::= SEQUENCE { sonusPktServProfileIndex Integer32, sonusPktServProfileState INTEGER, sonusPktServProfileName SonusName, sonusPktServProfileDestProtocol INTEGER, sonusPktServProfilePrfdAudioEncoding INTEGER, sonusPktServProfilePrfdFramesPerPacket Integer32, sonusPktServProfileDefFramesPerPacket Integer32, sonusPktServProfileDefAudioEnable INTEGER, sonusPktServProfileSilenceFactor Integer32, sonusPktServProfileVInitPlayoutBufDelay Integer32, sonusPktServProfileFaxRelay INTEGER, sonusPktServProfileDtmfRelay INTEGER, sonusPktServProfileFallbackHandling INTEGER, sonusPktServProfileTosValue Integer32, sonusPktServProfileDInitPlayoutBufDelay Integer32, sonusPktServProfileDataRtpPayloadType Integer32, sonusPktServProfileRowStatus RowStatus, sonusPktServProfileG711SendSidPackets INTEGER, sonusPktServProfileG711SidRtpPayloadType Integer32, sonusPktServProfileSidHeartbeat INTEGER, sonusPktServProfileRtcp INTEGER, sonusPktServProfilePacketLossThreshold Integer32, sonusPktServProfilePacketLossAction INTEGER, sonusPktServProfileRtpPeerAbsenceAction INTEGER, sonusPktServProfileDtmfRelayOutOfBand INTEGER, sonusPktServProfileDtmfRelayRemoveDigits INTEGER } sonusPktServProfileIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Identifies the target packet service profile entry." ::= { sonusPktServProfileEntry 1 } sonusPktServProfileState OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabled(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The administrative state of this packet service profile entry." DEFVAL { disabled } ::= { sonusPktServProfileEntry 2 } sonusPktServProfileName OBJECT-TYPE SYNTAX SonusName MAX-ACCESS read-write STATUS current DESCRIPTION "The user name of this packet service profile." ::= { sonusPktServProfileEntry 3 } sonusPktServProfileDestProtocol OBJECT-TYPE SYNTAX INTEGER { gsx(1), h323(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies the Packet Destination Protocal used. GSX - uses Sonus GSX-GSX MCS protocol. h323 - uses H.323 protocol." DEFVAL { gsx } ::= { sonusPktServProfileEntry 4 } sonusPktServProfilePrfdAudioEncoding OBJECT-TYPE SYNTAX INTEGER { g711(1), g711ss(2), g729a(4), g729ab(5) } MAX-ACCESS read-write STATUS current DESCRIPTION "The preferred audio encoding method to be performed on the packet data received from, and destined to the IP network. The possible options are: G.711, G.711 with Silence Suppression, G.729A and G.729A+B. The default encoding method is G.711. For G.711, the law is determined by Circuit Service Profile." DEFVAL { g711 } ::= { sonusPktServProfileEntry 5 } sonusPktServProfilePrfdFramesPerPacket OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies the Preferred Audio Encoding Packet Size in milliseconds. For G.711 encoding mode, valid values range from 10 ms to 40 ms, in increments of 5 ms. The default value for G.711 is 10 ms. For G.729 encoding mode, valid values from 10 ms to 40 ms, in increments of 10 ms. The default value for G.729 is 20 ms." DEFVAL { 10 } ::= { sonusPktServProfileEntry 6 } sonusPktServProfileDefFramesPerPacket OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies the default Audio Encoding Packet Size in milliseconds. For G.711 encoding mode, valid values range from 10 ms to 40 ms, in increments of 5 ms. The default value for G.711 is 10 ms. For G.729 encoding mode, valid values from 10 ms to 40 ms, in increments of 10 ms. The default value for G.729 is 20 ms." DEFVAL { 10 } ::= { sonusPktServProfileEntry 7 } sonusPktServProfileDefAudioEnable OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabled(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies whether or not to allow default Audio (G.711). If enabled, allow use of G.711 if preferred audio resource is not available. If disabled, Do not use of G.711 if preferred audio resource is not available and the call is disconnected." DEFVAL { enabled } ::= { sonusPktServProfileEntry 8 } sonusPktServProfileSilenceFactor OBJECT-TYPE SYNTAX Integer32 (0..50) MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies percentage of call time that silence is expected." DEFVAL { 0 } ::= { sonusPktServProfileEntry 9 } sonusPktServProfileVInitPlayoutBufDelay OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This value defines the size of the initial playout bufferrequired to absorb the maximum expected voice packet delay across the network. Range from 1 ms to 50 ms, in increments of 1 ms." DEFVAL { 10 } ::= { sonusPktServProfileEntry 10 } sonusPktServProfileFaxRelay OBJECT-TYPE SYNTAX INTEGER { never(0), useIfCompressedAudio(1), always(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "If never is specified, Fax Relay is not used regardless of the audio encoding method. If useIfCompressedAudio is specified, Fax Relay is used if the compressed resource is available. If always is specified, Fax Relay is used regardless of the audio encoding method." DEFVAL { never } ::= { sonusPktServProfileEntry 11 } sonusPktServProfileDtmfRelay OBJECT-TYPE SYNTAX INTEGER { never(0), useIfCompressedAudio(1), always(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "If never is specified, DTMF Relay is not used regardless of the audio encoding method. If useIfCompressedAudio is specified, DTMF Relay is used if the compressed resource is available. If always is specified, DTMF Relay is used regardless of the audio encoding method." DEFVAL { never } ::= { sonusPktServProfileEntry 12 } sonusPktServProfileFallbackHandling OBJECT-TYPE SYNTAX INTEGER { disconnet(1), continue(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This specifies the behavior when a compressed codec call needs to revert to G.711 (e.g., to pass modem data) and there is no bandwidth available." DEFVAL { continue } ::= { sonusPktServProfileEntry 13 } sonusPktServProfileTosValue OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies the Type Of Service (TOS) parameters to be provided in the IP header for voice packets. The TOS value is specified as an 8-bit hex value 0x00-0xFF allowing complete flexibility with respect to the contents of the TOS byte." DEFVAL { 0 } ::= { sonusPktServProfileEntry 14 } sonusPktServProfileDInitPlayoutBufDelay OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This value defines the size of the initial playout buffer required to absorb the maximum expected data packet delay across the network. Range from 5 ms to 50 ms, in increments of 1 ms. The default value is 50 ms." DEFVAL { 50 } ::= { sonusPktServProfileEntry 15 } sonusPktServProfileDataRtpPayloadType OBJECT-TYPE SYNTAX Integer32 (0..127) MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies the RTP payload type to be included in the RTP header of the data packet" DEFVAL { 56 } ::= { sonusPktServProfileEntry 16 } sonusPktServProfileRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-write STATUS current DESCRIPTION "" ::= { sonusPktServProfileEntry 17 } sonusPktServProfileG711SendSidPackets OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabled(2) } MAX-ACCESS read-write STATUS current DESCRIPTION " Specifies whether sending SID packets is enabled. This applies only if preferred audio encoding is G.711 with silence suppression." DEFVAL { enabled } ::= { sonusPktServProfileEntry 18 } sonusPktServProfileG711SidRtpPayloadType OBJECT-TYPE SYNTAX Integer32 (0..127) MAX-ACCESS read-write STATUS current DESCRIPTION " Specifies G.711 SID RTP payload type. This applies only if preferred audio encoding is G.711 with silence suppression. Range 0 to 127." DEFVAL { 19 } ::= { sonusPktServProfileEntry 19 } sonusPktServProfileSidHeartbeat OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabled(2) } MAX-ACCESS read-write STATUS current DESCRIPTION " Specifies whether sending SID heartbeat packets is enabled. This applies if preferred audio encoding is either G.711 with silence suppression or G.729A+B." DEFVAL { enabled } ::= { sonusPktServProfileEntry 20 } sonusPktServProfileRtcp OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabled(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies whether RTCP is enabled for the call." DEFVAL { disabled } ::= { sonusPktServProfileEntry 21 } sonusPktServProfilePacketLossThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " Specifies the RTCP packet loss threshold in packets/100,000. 0 means no detection. Requires RTCP to be enabled." DEFVAL { 0 } ::= { sonusPktServProfileEntry 22 } sonusPktServProfilePacketLossAction OBJECT-TYPE SYNTAX INTEGER { none(0), trap(1), trapAndDisconnect(3) } MAX-ACCESS read-write STATUS current DESCRIPTION " Specifies the action taken when the packet loss threshold is exceeded. Requires RTCP to be enabled." DEFVAL { none } ::= { sonusPktServProfileEntry 23 } sonusPktServProfileRtpPeerAbsenceAction OBJECT-TYPE SYNTAX INTEGER { none(0), trap(1), trapAndDisconnect(3) } MAX-ACCESS read-write STATUS current DESCRIPTION " Specifies the action taken when the RTP peer is detected to be absent (due to lack of RTP and RTCP packets). Requires RTCP to be enabled." DEFVAL { none } ::= { sonusPktServProfileEntry 24 } sonusPktServProfileDtmfRelayOutOfBand OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabled(2) } MAX-ACCESS read-write STATUS current DESCRIPTION " Specifies whether out of band DTMF relay is enabled. This applies if DTMF relay is configured as useIfCompressedAudio or always ." DEFVAL { disabled } ::= { sonusPktServProfileEntry 25 } sonusPktServProfileDtmfRelayRemoveDigits OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabled(2) } MAX-ACCESS read-write STATUS current DESCRIPTION " Specifies whether removing DTMF digits from the media stream is enabled. This applies if DTMF relay is configured as useIfCompressedAudio or always ." DEFVAL { enabled } ::= { sonusPktServProfileEntry 26 } sonusDisconnectTreatmentObjects OBJECT IDENTIFIER ::= { sonusNodeResourcesMIBObjects 14 } sonusDiscTreatProfile OBJECT IDENTIFIER ::= { sonusDisconnectTreatmentObjects 1 } sonusDiscTreatProfileNextIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The next valid index to use when creating an entry in the sonusDiscTreatProfileTable." ::= { sonusDiscTreatProfile 1 } sonusDiscTreatProfileTable OBJECT-TYPE SYNTAX SEQUENCE OF SonusDiscTreatProfileEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains Disconnect Treatment Profiles for the node." ::= { sonusDiscTreatProfile 2 } sonusDiscTreatProfileEntry OBJECT-TYPE SYNTAX SonusDiscTreatProfileEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { sonusDiscTreatProfileIndex } ::= { sonusDiscTreatProfileTable 1 } SonusDiscTreatProfileEntry ::= SEQUENCE { sonusDiscTreatProfileIndex Integer32, sonusDiscTreatProfileName SonusName, sonusDiscTreatProfileRowStatus RowStatus } sonusDiscTreatProfileIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Identifies the Disconnect Treatment Profile." ::= { sonusDiscTreatProfileEntry 1 } sonusDiscTreatProfileName OBJECT-TYPE SYNTAX SonusName MAX-ACCESS read-write STATUS current DESCRIPTION "The user name of this Disconnect Treatment Profile." ::= { sonusDiscTreatProfileEntry 2 } sonusDiscTreatProfileRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-write STATUS current DESCRIPTION "" ::= { sonusDiscTreatProfileEntry 3 } sonusDiscTreatmentAdmnTable OBJECT-TYPE SYNTAX SEQUENCE OF SonusDiscTreatmentAdmnEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= { sonusDisconnectTreatmentObjects 2 } sonusDiscTreatmentAdmnEntry OBJECT-TYPE SYNTAX SonusDiscTreatmentAdmnEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { sonusDiscTreatmentProfileIndex, sonusDiscTreatmentIndex } ::= { sonusDiscTreatmentAdmnTable 1 } SonusDiscTreatmentAdmnEntry ::= SEQUENCE { sonusDiscTreatmentProfileIndex Integer32, sonusDiscTreatmentIndex Integer32, sonusDiscTreatmentReason Integer32, sonusDiscTreatmentSigSeqProfileName SonusNameReference, sonusDiscTreatmentRowStatus RowStatus } sonusDiscTreatmentProfileIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Identifies the Disconnect Treatment Profile to which this entry belongs." ::= { sonusDiscTreatmentAdmnEntry 1 } sonusDiscTreatmentIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Identifies the target Disconnect Treatment entry." ::= { sonusDiscTreatmentAdmnEntry 2 } sonusDiscTreatmentReason OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Disconnect Reason Code." ::= { sonusDiscTreatmentAdmnEntry 3 } sonusDiscTreatmentSigSeqProfileName OBJECT-TYPE SYNTAX SonusNameReference MAX-ACCESS read-write STATUS current DESCRIPTION "For given Disconnect Treatment Profile and Disconnect Reason Code, execute this Disconnect SSP." ::= { sonusDiscTreatmentAdmnEntry 4 } sonusDiscTreatmentRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-write STATUS current DESCRIPTION "" ::= { sonusDiscTreatmentAdmnEntry 5 } sonusDiscSspGroupAdmn OBJECT IDENTIFIER ::= { sonusDisconnectTreatmentObjects 3 } sonusDiscSspNextIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The next valid index to use when creating a new sonusDiscSspGroupAdmnEntry" ::= { sonusDiscSspGroupAdmn 1 } sonusDiscSspAdmnTable OBJECT-TYPE SYNTAX SEQUENCE OF SonusDiscSspAdmnEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= { sonusDiscSspGroupAdmn 2 } sonusDiscSspAdmnEntry OBJECT-TYPE SYNTAX SonusDiscSspAdmnEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { sonusDiscSigSeqProfileIndex } ::= { sonusDiscSspAdmnTable 1 } SonusDiscSspAdmnEntry ::= SEQUENCE { sonusDiscSigSeqProfileIndex Integer32, sonusDiscSigSeqProfileName SonusName, sonusDiscSigSeqProfileRowStatus RowStatus } sonusDiscSigSeqProfileIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Identifies the target Disconnect Signal Sequence Profile." ::= { sonusDiscSspAdmnEntry 1 } sonusDiscSigSeqProfileName OBJECT-TYPE SYNTAX SonusName MAX-ACCESS read-write STATUS current DESCRIPTION "The user name of this Disconnect Signal Sequence Profile." ::= { sonusDiscSspAdmnEntry 2 } sonusDiscSigSeqProfileRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-write STATUS current DESCRIPTION "" ::= { sonusDiscSspAdmnEntry 3 } sonusDiscSigSeqAdmnTable OBJECT-TYPE SYNTAX SEQUENCE OF SonusDiscSigSeqAdmnEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= { sonusDisconnectTreatmentObjects 4 } sonusDiscSigSeqAdmnEntry OBJECT-TYPE SYNTAX SonusDiscSigSeqAdmnEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { sonusDiscSigSequenceProfileIndex, sonusDiscSigSequenceIndex } ::= { sonusDiscSigSeqAdmnTable 1 } SonusDiscSigSeqAdmnEntry ::= SEQUENCE { sonusDiscSigSequenceProfileIndex Integer32, sonusDiscSigSequenceIndex Integer32, sonusDiscSigSequencePosition Integer32, sonusDiscSigSequenceToken INTEGER, sonusDiscSigSequenceParam1 DisplayString, sonusDiscSigSequenceParam2 DisplayString, sonusDiscSigSequenceAdminState SonusAdminState, sonusDiscSigSequenceRowStatus RowStatus } sonusDiscSigSequenceProfileIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= { sonusDiscSigSeqAdmnEntry 1 } sonusDiscSigSequenceIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= { sonusDiscSigSeqAdmnEntry 2 } sonusDiscSigSequencePosition OBJECT-TYPE SYNTAX Integer32 (0..31) MAX-ACCESS read-write STATUS current DESCRIPTION "" DEFVAL { 0 } ::= { sonusDiscSigSeqAdmnEntry 3 } sonusDiscSigSequenceToken OBJECT-TYPE SYNTAX INTEGER { playTone(7), playAnn(8), delay(9), clear(16), exec(17) } MAX-ACCESS read-write STATUS current DESCRIPTION "" DEFVAL { clear } ::= { sonusDiscSigSeqAdmnEntry 4 } sonusDiscSigSequenceParam1 OBJECT-TYPE SYNTAX DisplayString (SIZE(0..31)) MAX-ACCESS read-write STATUS current DESCRIPTION "" ::= { sonusDiscSigSeqAdmnEntry 5 } sonusDiscSigSequenceParam2 OBJECT-TYPE SYNTAX DisplayString (SIZE(0..31)) MAX-ACCESS read-write STATUS current DESCRIPTION "" ::= { sonusDiscSigSeqAdmnEntry 6 } sonusDiscSigSequenceAdminState OBJECT-TYPE SYNTAX SonusAdminState MAX-ACCESS read-write STATUS current DESCRIPTION "" DEFVAL { disabled } ::= { sonusDiscSigSeqAdmnEntry 7 } sonusDiscSigSequenceRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-write STATUS current DESCRIPTION "" ::= { sonusDiscSigSeqAdmnEntry 8 } sonusTestCall OBJECT IDENTIFIER ::= { sonusNodeResourcesMIBObjects 15 } sonusTestCallNextIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The next valid index to use when creating an entry in the sonusTestCallAdmnTable" ::= { sonusTestCall 1 } sonusTestCallAdmnTable OBJECT-TYPE SYNTAX SEQUENCE OF SonusTestCallAdmnEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table specifies the test call list for the node." ::= { sonusTestCall 2 } sonusTestCallAdmnEntry OBJECT-TYPE SYNTAX SonusTestCallAdmnEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { sonusTestCallAdmnIndex } ::= { sonusTestCallAdmnTable 1 } SonusTestCallAdmnEntry ::= SEQUENCE { sonusTestCallAdmnIndex Integer32, sonusTestCallAdmnState INTEGER, sonusTestCallAdmnName SonusName, sonusTestCallAdmnEndPointShelf Integer32, sonusTestCallAdmnEndPointSlot Integer32, sonusTestCallAdmnEndPointPort Integer32, sonusTestCallAdmnEndPointChannel Integer32, sonusTestCallAdmnRowStatus RowStatus, sonusTestCallAdmnType INTEGER, sonusTestCallAdmnPower Integer32, sonusTestCallAdmnFrequency Integer32, sonusTestCallAdmnStatPower Integer32, sonusTestCallAdmnStatPowerTenths Integer32 } sonusTestCallAdmnIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Identifies the target test call entry." ::= { sonusTestCallAdmnEntry 1 } sonusTestCallAdmnState OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "The administrative state of this test call entry." DEFVAL { disabled } ::= { sonusTestCallAdmnEntry 2 } sonusTestCallAdmnName OBJECT-TYPE SYNTAX SonusName MAX-ACCESS read-write STATUS current DESCRIPTION "The user name of this test call." ::= { sonusTestCallAdmnEntry 3 } sonusTestCallAdmnEndPointShelf OBJECT-TYPE SYNTAX Integer32 (1..6) MAX-ACCESS read-write STATUS current DESCRIPTION "A 32-bit integer identifying the shelf of the end point" ::= { sonusTestCallAdmnEntry 4 } sonusTestCallAdmnEndPointSlot OBJECT-TYPE SYNTAX Integer32 (1..16) MAX-ACCESS read-write STATUS current DESCRIPTION "A 32-bit integer identifying the slot of the end point" ::= { sonusTestCallAdmnEntry 5 } sonusTestCallAdmnEndPointPort OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "Port index of end point." ::= { sonusTestCallAdmnEntry 6 } sonusTestCallAdmnEndPointChannel OBJECT-TYPE SYNTAX Integer32 (1..32) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the DS0 channel of the end point." ::= { sonusTestCallAdmnEntry 7 } sonusTestCallAdmnRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-write STATUS current DESCRIPTION "" ::= { sonusTestCallAdmnEntry 8 } sonusTestCallAdmnType OBJECT-TYPE SYNTAX INTEGER { listen(0), play(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "The circuit type for this test call." DEFVAL { listen } ::= { sonusTestCallAdmnEntry 9 } sonusTestCallAdmnPower OBJECT-TYPE SYNTAX Integer32 (-50..3) MAX-ACCESS read-write STATUS current DESCRIPTION "The power in dBm of the tone to play." DEFVAL { -6 } ::= { sonusTestCallAdmnEntry 10 } sonusTestCallAdmnFrequency OBJECT-TYPE SYNTAX Integer32 (0..3999) MAX-ACCESS read-write STATUS current DESCRIPTION "The frequency in Hz of the tone to play or listen for." DEFVAL { 1004 } ::= { sonusTestCallAdmnEntry 11 } sonusTestCallAdmnStatPower OBJECT-TYPE SYNTAX Integer32 (-1000..3) MAX-ACCESS read-write STATUS current DESCRIPTION "The dBm of the tone received in LISTEN mode." DEFVAL { -1000 } ::= { sonusTestCallAdmnEntry 12 } sonusTestCallAdmnStatPowerTenths OBJECT-TYPE SYNTAX Integer32 (0..9) MAX-ACCESS read-write STATUS current DESCRIPTION "The tenths of dBm of the tone received in LISTEN mode." DEFVAL { 0 } ::= { sonusTestCallAdmnEntry 13 } sonusTestCallStatTable OBJECT-TYPE SYNTAX SEQUENCE OF SonusTestCallStatEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Manual Call Stat Table" ::= { sonusNodeResourcesMIBObjects 16 } sonusTestCallStatEntry OBJECT-TYPE SYNTAX SonusTestCallStatEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the Manual Call Stat Table" INDEX { sonusTestCallStatIndex } ::= { sonusTestCallStatTable 1 } SonusTestCallStatEntry ::= SEQUENCE { sonusTestCallStatIndex Integer32, sonusTestCallStatCallId Integer32, sonusTestCallStatState DisplayString, sonusTestCallStatTime DisplayString } sonusTestCallStatIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index for target test call." ::= { sonusTestCallStatEntry 1 } sonusTestCallStatCallId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The call identifier(GCID) assigned to this test call" ::= { sonusTestCallStatEntry 2 } sonusTestCallStatState OBJECT-TYPE SYNTAX DisplayString (SIZE(0..23)) MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the test call" ::= { sonusTestCallStatEntry 3 } sonusTestCallStatTime OBJECT-TYPE SYNTAX DisplayString (SIZE(0..23)) MAX-ACCESS read-only STATUS current DESCRIPTION "Displays the Date/time the connection was created" ::= { sonusTestCallStatEntry 4 } sonusTestCallActionObjects OBJECT IDENTIFIER ::= { sonusNodeResourcesMIBObjects 17 } sonusTestCallGcid OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The call identifier for a call to be deleted" ::= { sonusTestCallActionObjects 1 } sonusTestCallAction OBJECT-TYPE SYNTAX INTEGER { none(1), delete(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The action that should be taken on the call" DEFVAL { none } ::= { sonusTestCallActionObjects 2 } sonusNodeResourcesMIBNotifications OBJECT IDENTIFIER ::= { sonusNodeResourcesMIB 2 } sonusNodeResourcesMIBNotificationsPrefix OBJECT IDENTIFIER ::= { sonusNodeResourcesMIBNotifications 0 } sonusNodeResourcesMIBNotificationsObjects OBJECT IDENTIFIER ::= { sonusNodeResourcesMIBNotifications 1 } sonusCallAdmissionChangeReason OBJECT-TYPE SYNTAX DisplayString (SIZE(1..101)) MAX-ACCESS read-only STATUS current DESCRIPTION "The reason why the call admission control state has changes." ::= { sonusNodeResourcesMIBNotificationsObjects 1 } sonusNodeResourcesCallAdmissionSuspendedNotification NOTIFICATION-TYPE OBJECTS { sonusCallAdmissionChangeReason, sonusEventDescription, sonusEventClass, sonusEventLevel } STATUS current DESCRIPTION "This trap indicates that call admission into the GSX has been suspended. Information provided by this trap includes the reason why call admission has been suspended." ::= { sonusNodeResourcesMIBNotificationsPrefix 1 } sonusNodeResourcesCallAdmissionEnabledNotification NOTIFICATION-TYPE OBJECTS { sonusCallAdmissionChangeReason, sonusEventDescription, sonusEventClass, sonusEventLevel } STATUS current DESCRIPTION "This trap indicates that call admission into the GSX has been enabled. Information provided by this trap includes the reason why call admission has been enabled." ::= { sonusNodeResourcesMIBNotificationsPrefix 2 } sonusNodeResourcesCallTraceHitNotification NOTIFICATION-TYPE OBJECTS { sonusCallTraceCalledNumber, sonusCallTraceCallingNumber, sonusEventDescription, sonusEventClass, sonusEventLevel } STATUS current DESCRIPTION "This trap indicates that call trace filter had a hit. Information provided by this trap includes the called number and the calling number." ::= { sonusNodeResourcesMIBNotificationsPrefix 3 } END -- end of module SONUS-NODE-RESOURCES-MIB.