SNI-BUS-MIB DEFINITIONS ::= BEGIN -- -- $Copyright$ -- Copyright (C) Siemens Nixdorf Informationssysteme AG 1995 -- Copyright (C) Fujitsu Siemens Computers GmbH 2001 -- Copyright (C) Fujitsu Technology Solutions GmbH 2010 -- All rights reserved -- IMPORTS OBJECT-TYPE FROM RFC-1212 mib-2, DisplayString FROM RFC1213-MIB TimeTicks, Counter, Gauge, enterprises FROM RFC1155-SMI; -- -- The Windows NT MIB compiler doesn't do IMPORTS. -- So, include these definitions here. NT defines "DisplayString" as -- OCTET STRING (SIZE(0..255)), in RFC1213 it has no explicit size. -- -- DisplayString ::= OCTET STRING -- enterprises OBJECT IDENTIFIER ::= { iso org(3) dod(6) internet(1) private(4) 1 } -- -- SNI Server Management MIB nodes sni OBJECT IDENTIFIER ::= { enterprises 231 } sniProductMibs OBJECT IDENTIFIER ::= { sni 2 } sniExtensions OBJECT IDENTIFIER ::= { sniProductMibs 10 } sniServerMgmt OBJECT IDENTIFIER ::= { sniExtensions 2 } sniInventory OBJECT IDENTIFIER ::= { sniServerMgmt 1 } sniCommon OBJECT IDENTIFIER ::= { sniServerMgmt 2 } sniBios OBJECT IDENTIFIER ::= { sniCommon 1 } sniEisa OBJECT IDENTIFIER ::= { sniCommon 2 } sniHd OBJECT IDENTIFIER ::= { sniCommon 3 } sniBus OBJECT IDENTIFIER ::= { sniCommon 4 } sniServerControl OBJECT IDENTIFIER ::= { sniCommon 5 } sniPcSpecific OBJECT IDENTIFIER ::= { sniServerMgmt 3 } sniScb OBJECT IDENTIFIER ::= { sniServerMgmt 4 } sniOsSpecific OBJECT IDENTIFIER ::= { sniServerMgmt 5 } sniNetware OBJECT IDENTIFIER ::= { sniOsSpecific 1 } sniWinNt OBJECT IDENTIFIER ::= { sniOsSpecific 2 } sniOs2 OBJECT IDENTIFIER ::= { sniOsSpecific 3 } sniUnix OBJECT IDENTIFIER ::= { sniOsSpecific 4 } sniOemComponents OBJECT IDENTIFIER ::= { sniServerMgmt 6 } sniOemDpt OBJECT IDENTIFIER ::= { sniOemComponents 1 } sniOemMylex OBJECT IDENTIFIER ::= { sniOemComponents 2 } sniMlxDiskArray OBJECT IDENTIFIER ::= { sniOemMylex 1 } sniSecurity OBJECT IDENTIFIER ::= { sniServerMgmt 7 } sniSmSecurity OBJECT IDENTIFIER ::= { sniSecurity 1 } sniServerView OBJECT IDENTIFIER ::= { sniServerMgmt 8 } sniTrapMib OBJECT IDENTIFIER ::= { sniExtensions 5 } ---------------------------------------------------------------------------------------- -- -- ServerView-MIB groups sniBusCommon OBJECT IDENTIFIER ::= { sniBus 1 } sniBusEisa OBJECT IDENTIFIER ::= { sniBus 2 } sniBusPci OBJECT IDENTIFIER ::= { sniBus 3 } sniBusResource OBJECT IDENTIFIER ::= { sniBus 4 } sniBusSummary OBJECT IDENTIFIER ::= { sniBus 5 } svBusPciEx OBJECT IDENTIFIER ::= { sniBus 6 } -- ********************************************************************************************** -- -- GROUP sniBusCommon -- DESCRIPTION "This group describes common bus information data" -- Implementation of this group is mandatory -- -- sniBusCommon group: 1.3.6.1.4.1.231.2.10.2.2.4.1 -- -- ********************************************************************************************** sniEisaSlots OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of eisa slots in the system. 0 if no EISA-Bus present." ::= { sniBusCommon 1 } sniIsaSlots OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of isa slots in the system. 0 if no ISA-Bus present." ::= { sniBusCommon 2 } sniPciSlots OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of pci slots in the system. 0 if no PCI-Bus present." ::= { sniBusCommon 3 } -- ---------------------------------------------------------------------------------------------- -- -- TABLE sniFunctionTable -- STATUS mandatory -- DESCRIPTION "Description of bus functions" -- -- sniFunctionTable: 1.3.6.1.4.1.231.2.10.2.2.4.1.4 -- -- ---------------------------------------------------------------------------------------------- sniFunctionTable OBJECT-TYPE SYNTAX SEQUENCE OF SniFunctionEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of all common data for all functions" ::= { sniBusCommon 4 } sniFunctionEntry OBJECT-TYPE SYNTAX SniFunctionEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " " INDEX { sniBusType, sniBusIndex, sniDeviceSlotNo, sniFunctionNo } ::= { sniFunctionTable 1 } SniFunctionEntry ::= SEQUENCE { sniBusType INTEGER, sniBusIndex INTEGER, sniDeviceSlotNo INTEGER, sniFunctionNo INTEGER, sniDeviceType INTEGER, sniDeviceTypeName DisplayString, sniDeviceName DisplayString, sniVendorName DisplayString, sniPhysicalSlotNo INTEGER, sniAdapterSpecificData OCTET STRING, sniOsDeviceName DisplayString, sniPhysicalSlotDesignation DisplayString, sniCompLocationKey OCTET STRING } sniBusType OBJECT-TYPE SYNTAX INTEGER { unknown(0), isa(2), eisa(3), pci(5), usb(6), firewire(7), ata(8) } ACCESS read-only STATUS mandatory DESCRIPTION "Type of the bus" ::= { sniFunctionEntry 1 } sniBusIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Index of the bus based on 1" ::= { sniFunctionEntry 2 } sniDeviceSlotNo OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Device- or Slot-number based on 0" ::= { sniFunctionEntry 3 } sniFunctionNo OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Functionnumber based on 1" ::= { sniFunctionEntry 4 } sniDeviceType OBJECT-TYPE SYNTAX INTEGER { unknown(0), diskcontroller(1), tapecontroller(2), cdromcontoller(3), wormcontroller (4), serialcontroller(5), networkcontroller(6), displaycontroller(7), parallelcontroller(8), pointercontoller(9), keyboardcontroller(10), audiocontroller(11), othercontroller(12), bridge-device(13), cpu(14) } ACCESS read-only STATUS mandatory DESCRIPTION "indicates the type of device" ::= { sniFunctionEntry 5 } sniDeviceTypeName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "type of device in readable form" ::= { sniFunctionEntry 6 } sniDeviceName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Operating system independent name of device in readable form" ::= { sniFunctionEntry 7 } sniVendorName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "manufacturer of the device in readable form" ::= { sniFunctionEntry 8 } sniPhysicalSlotNo OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "indicates the physical slot the device resides in (0: onboard device, -1: not available)" ::= { sniFunctionEntry 9 } sniAdapterSpecificData OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Specific data for this adapter. Currently the only information defined is the MAC address for lan adapters." ::= { sniFunctionEntry 10 } sniOsDeviceName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Operating system specific display name for the device" ::= { sniFunctionEntry 11 } sniPhysicalSlotDesignation OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Designation of the physical slot where the device is plugged in" ::= { sniFunctionEntry 12 } sniCompLocationKey OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Device location key, used for identifying the component; e.g. 'TYPE_PCI&BUS_3&DEV_14&FUNC_0'" ::= { sniFunctionEntry 13 } -- ********************************************************************************************** -- -- GROUP sniBusEisa -- DESCRIPTION "This group describes all EISA bus components" -- Implementation of this group is optional -- -- sniBusEisa group: 1.3.6.1.4.1.231.2.10.2.2.4.2 -- -- ********************************************************************************************** -- ---------------------------------------------------------------------------------------------- -- -- TABLE sniEisaFunctionTable -- STATUS mandatory -- DESCRIPTION "Description of all EISA bus functions" -- -- sniEisaFunctionTable: 1.3.6.1.4.1.231.2.10.2.2.4.2.1 -- -- ---------------------------------------------------------------------------------------------- sniEisaFunctionTable OBJECT-TYPE SYNTAX SEQUENCE OF SniEisaFunctionEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of all eisa function entries" ::= { sniBusEisa 1 } sniEisaFunctionEntry OBJECT-TYPE SYNTAX SniEisaFunctionEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " " INDEX { sniEisaBusIndex, sniEisaSlotNo, sniEisaFunctionNo } ::= { sniEisaFunctionTable 1 } SniEisaFunctionEntry ::= SEQUENCE { sniEisaBusIndex INTEGER, sniEisaSlotNo INTEGER, sniEisaFunctionNo INTEGER, sniEisaSlotType INTEGER, sniEisaConfigurationComplete INTEGER, sniEisaType DisplayString, sniEisaValid INTEGER, sniEisaId DisplayString, sniEisaName DisplayString, sniEisaAgentType INTEGER } sniEisaBusIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Index of the bus based on 1" ::= { sniEisaFunctionEntry 1 } sniEisaSlotNo OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Slot number based on 0" ::= { sniEisaFunctionEntry 2 } sniEisaFunctionNo OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Eisa function number based on 1" ::= { sniEisaFunctionEntry 3 } sniEisaSlotType OBJECT-TYPE SYNTAX INTEGER { expansion-slot(1), embedded-slot(2), virtual-slot(3), reserved(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Type of the slot" ::= { sniEisaFunctionEntry 4 } sniEisaConfigurationComplete OBJECT-TYPE SYNTAX INTEGER { true(1), false(2), unknown(3) } ACCESS read-only STATUS mandatory DESCRIPTION "True if board is completely configured" ::= { sniEisaFunctionEntry 5 } sniEisaType OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Type and subtype as ASCII string" ::= { sniEisaFunctionEntry 6 } sniEisaValid OBJECT-TYPE SYNTAX INTEGER { true(1), false(2), unknown(3) } ACCESS read-only STATUS mandatory DESCRIPTION "True, if the slot contains a correctly configured eisa board." ::= { sniEisaFunctionEntry 7 } sniEisaId OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The eisa id of the board." ::= { sniEisaFunctionEntry 8 } sniEisaName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Visual name of the board." ::= { sniEisaFunctionEntry 9 } sniEisaAgentType OBJECT-TYPE SYNTAX INTEGER { other(1), ethernet-adapter(2), token-ring-adapter(3), fddi-adapter(4), hd-adapter(5), extended-hd-adapter(6), cpu(7) } ACCESS read-only STATUS mandatory DESCRIPTION " " ::= { sniEisaFunctionEntry 10 } -- ********************************************************************************************** -- -- GROUP sniBusPci -- DESCRIPTION "This group describes all PCI bus components and functions" -- Implementation of this group is optional -- -- sniBusPci group: 1.3.6.1.4.1.231.2.10.2.2.4.3 -- -- ********************************************************************************************** -- ---------------------------------------------------------------------------------------------- -- -- TABLE sniPciFunctionTable -- STATUS mandatory -- DESCRIPTION "Description of all PCI bus functions" -- -- sniPciFunctionTable: 1.3.6.1.4.1.231.2.10.2.2.4.3.1 -- -- ---------------------------------------------------------------------------------------------- sniPciFunctionTable OBJECT-TYPE SYNTAX SEQUENCE OF SniPciFunctionEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of all pci function entries" ::= { sniBusPci 1 } sniPciFunctionEntry OBJECT-TYPE SYNTAX SniPciFunctionEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " " INDEX { sniPciBusIndex, sniPciDeviceNo, sniPciFunctionNo } ::= { sniPciFunctionTable 1 } SniPciFunctionEntry ::= SEQUENCE { sniPciBusIndex INTEGER, sniPciDeviceNo INTEGER, sniPciFunctionNo INTEGER, sniPciVendorId INTEGER, sniPciDeviceId INTEGER, sniPciRevisionId INTEGER, sniPciBaseClass INTEGER, sniPciSubClass INTEGER, sniPciProgIf INTEGER, sniPciBuiltInSelfTest INTEGER, sniPciInterruptPin INTEGER, sniPciInterruptLine INTEGER, sniPciSpecificData OCTET STRING, sniPciSecondaryBusIndex INTEGER, sniPciSecondaryBusType INTEGER, sniPciSubDeviceId INTEGER, sniPciSubVendorId INTEGER, sniPciVendorName DisplayString, sniPciSubVendorName DisplayString } sniPciBusIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Index of the bus based on 1" ::= { sniPciFunctionEntry 1 } sniPciDeviceNo OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Device number based on 0" ::= { sniPciFunctionEntry 2 } sniPciFunctionNo OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Function number based on 1" ::= { sniPciFunctionEntry 3 } sniPciVendorId OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Identifies the manufacturer of the device. This must be a value allocated by the PCI SIG." ::= { sniPciFunctionEntry 4 } sniPciDeviceId OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Identifies the particular device. This value is assigned by the manufacturer." ::= { sniPciFunctionEntry 5 } sniPciRevisionId OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Specifies the revision level of the device described by sniPciDeviceId. This value is assigned by the manufacturer." ::= { sniPciFunctionEntry 6 } sniPciBaseClass OBJECT-TYPE SYNTAX INTEGER { old-type-device(0), mass-storage-controller(1), network-controller(2), display-controller(3), multimedia-device(4), memory-controller(5), bridge-device(6), simple-communication-controller(7), base-system-peripheral(8), input-device(9), docking-station(10), processor(11), serial-bus-controller(12), wireless-controller(13), io-controller(14), satellite-communication-controller(15), encryption-device(16), signal-processor(17), unknown-device(255) } ACCESS read-only STATUS mandatory DESCRIPTION "Identifies type of the device, according to the PCI classification scheme." ::= { sniPciFunctionEntry 7 } sniPciSubClass OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Identifies the subtype, if any, of the device, according to the PCI classification scheme." ::= { sniPciFunctionEntry 8 } sniPciProgIf OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Identifies the register-level programming interface, if any, for the device, according to the PCI classification scheme." ::= { sniPciFunctionEntry 9 } sniPciBuiltInSelfTest OBJECT-TYPE SYNTAX INTEGER { built-in(1), not-built-in(2), unknown(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates if the device does support built-in self test." ::= { sniPciFunctionEntry 10 } sniPciInterruptPin OBJECT-TYPE SYNTAX INTEGER { not-implemented(0), inta(1), intb(2), intc(3), intd(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates which interrupt pin the PCI device uses." ::= { sniPciFunctionEntry 11 } sniPciInterruptLine OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the input of the system interrupt controller that the interrupt pin is connected to." ::= { sniPciFunctionEntry 12 } sniPciSpecificData OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "This is device specific data found in the COMMON CONFIGURATION SPACE. This field is currently not used and therefor filled with zeros." ::= { sniPciFunctionEntry 13 } sniPciSecondaryBusIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Valid only for a bridge device. This is the index of the bridge's secondary bus (-1 = no bus index available; ignore this field)." ::= { sniPciFunctionEntry 14 } sniPciSecondaryBusType OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Valid only for a bridge device. This is the type of the bridge's secondary bus. Following values are defined (according to PCI Local bus specification, Revision 2.1, values are incremented by 1): 00h: Unknown value; ignore this field 01h: Host bridge (bridge to CPU bus) 02h: ISA bridge 03h: EISA bridge 04h: MCA bridge 05h: PCI-to-PCI bridge 06h: PCMCIA bridge 07h: NuBus bridge 80h: Other bridge device" ::= { sniPciFunctionEntry 15 } sniPciSubVendorId OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Identifies the particular device. This value is assigned by the manufacturer." ::= { sniPciFunctionEntry 16 } sniPciSubDeviceId OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Identifies the particular device. This value is assigned by the manufacturer." ::= { sniPciFunctionEntry 17 } sniPciVendorName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "PCI device vendor name" ::= { sniPciFunctionEntry 18 } sniPciSubVendorName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "PCI device sub vendor name" ::= { sniPciFunctionEntry 19 } -- ********************************************************************************************** -- -- GROUP sniBusResource -- DESCRIPTION "This group describes all bus resources" -- Implementation of this group is mandatory -- -- sniBusResource group: 1.3.6.1.4.1.231.2.10.2.2.4.4 -- -- ********************************************************************************************** -- ---------------------------------------------------------------------------------------------- -- -- TABLE sniMemoryTable -- STATUS mandatory -- DESCRIPTION "Description of all bus memory data" -- -- sniMemoryTable: 1.3.6.1.4.1.231.2.10.2.2.4.4.1 -- -- ---------------------------------------------------------------------------------------------- sniMemoryTable OBJECT-TYPE SYNTAX SEQUENCE OF SniMemoryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of all memory entries" ::= { sniBusResource 1 } sniMemoryEntry OBJECT-TYPE SYNTAX SniMemoryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " " INDEX { sniMemBusType, sniMemBusIndex, sniMemSlotDevice, sniMemFunctionNo, sniMemoryNo } ::= { sniMemoryTable 1 } SniMemoryEntry ::= SEQUENCE { sniMemBusType INTEGER, sniMemBusIndex INTEGER, sniMemSlotDevice INTEGER, sniMemFunctionNo INTEGER, sniMemoryNo INTEGER, sniBusSharedMemory INTEGER, sniBusMemoryStart INTEGER, sniBusMemoryLength INTEGER, sniBusMemoryStartHigh INTEGER } sniMemBusType OBJECT-TYPE SYNTAX INTEGER { unknown(0), isa(2), eisa(3), pci(5) } ACCESS read-only STATUS mandatory DESCRIPTION "Type of the bus" ::= { sniMemoryEntry 1 } sniMemBusIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Index of the bus based on 1" ::= { sniMemoryEntry 2 } sniMemSlotDevice OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Slot or Device number based on 0" ::= { sniMemoryEntry 3 } sniMemFunctionNo OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Function number based on 1" ::= { sniMemoryEntry 4 } sniMemoryNo OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Memory number based on 1" ::= { sniMemoryEntry 5 } sniBusSharedMemory OBJECT-TYPE SYNTAX INTEGER { not-used(1), other(2), system(3), expanded(4), virtual(5) } ACCESS read-only STATUS mandatory DESCRIPTION "Type of shared memory" ::= { sniMemoryEntry 6 } sniBusMemoryStart OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Start address (low DWORD part) of shared memory or 0 if not used" ::= { sniMemoryEntry 7 } sniBusMemoryLength OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Length of shared memory or 0 if not used" ::= { sniMemoryEntry 8 } sniBusMemoryStartHigh OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Start address (high DWORD part) of shared memory or 0 if not used" ::= { sniMemoryEntry 9 } -- ---------------------------------------------------------------------------------------------- -- -- TABLE sniInterruptTable -- STATUS mandatory -- DESCRIPTION "Description of all bus interrupt information" -- -- sniInterruptTable: 1.3.6.1.4.1.231.2.10.2.2.4.4.2 -- -- ---------------------------------------------------------------------------------------------- sniInterruptTable OBJECT-TYPE SYNTAX SEQUENCE OF SniInterruptEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of all interrupt entries" ::= { sniBusResource 2 } sniInterruptEntry OBJECT-TYPE SYNTAX SniInterruptEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " " INDEX { sniIntBusType, sniIntBusIndex, sniIntSlotDevice, sniIntFunctionNo, sniInterruptNo } ::= { sniInterruptTable 1 } SniInterruptEntry ::= SEQUENCE { sniIntBusType INTEGER, sniIntBusIndex INTEGER, sniIntSlotDevice INTEGER, sniIntFunctionNo INTEGER, sniInterruptNo INTEGER, sniBusInterruptUsed INTEGER, sniBusInterruptLevel INTEGER, sniBusInterruptShared INTEGER, sniBusInterruptNo INTEGER } sniIntBusType OBJECT-TYPE SYNTAX INTEGER { unknown(0), isa(2), eisa(3), pci(5) } ACCESS read-only STATUS mandatory DESCRIPTION "Type of the bus" ::= { sniInterruptEntry 1 } sniIntBusIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Index of the bus based on 1" ::= { sniInterruptEntry 2 } sniIntSlotDevice OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Slot or Device number based on 0" ::= { sniInterruptEntry 3 } sniIntFunctionNo OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Function number based on 1" ::= { sniInterruptEntry 4 } sniInterruptNo OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Interrupt number based on 1" ::= { sniInterruptEntry 5 } sniBusInterruptUsed OBJECT-TYPE SYNTAX INTEGER { true(1), false(2), unknown(3) } ACCESS read-only STATUS mandatory DESCRIPTION "True if and only if not unknown and an interrupt is used" ::= { sniInterruptEntry 6 } sniBusInterruptLevel OBJECT-TYPE SYNTAX INTEGER { other(1), edge-triggered(2), level-triggered(3) } ACCESS read-only STATUS mandatory DESCRIPTION "interrupt level" ::= { sniInterruptEntry 7 } sniBusInterruptShared OBJECT-TYPE SYNTAX INTEGER { true(1), false(2), unknown(3) } ACCESS read-only STATUS mandatory DESCRIPTION "True if and only if not unknown and an interrupt is shared" ::= { sniInterruptEntry 8 } sniBusInterruptNo OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "interrupt number used" ::= { sniInterruptEntry 9 } -- ---------------------------------------------------------------------------------------------- -- -- TABLE sniDMATable -- STATUS mandatory -- DESCRIPTION "Description of all bus DMA information" -- -- sniDMATable: 1.3.6.1.4.1.231.2.10.2.2.4.4.3 -- -- ---------------------------------------------------------------------------------------------- sniDMATable OBJECT-TYPE SYNTAX SEQUENCE OF SniDMAEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of all dma entries" ::= { sniBusResource 3 } sniDMAEntry OBJECT-TYPE SYNTAX SniDMAEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " " INDEX { sniDMABusType, sniDMABusIndex, sniDMASlotDevice, sniDMAFunctionNo, sniDMANo } ::= { sniDMATable 1 } SniDMAEntry ::= SEQUENCE { sniDMABusType INTEGER, sniDMABusIndex INTEGER, sniDMASlotDevice INTEGER, sniDMAFunctionNo INTEGER, sniDMANo INTEGER, sniBusDMAChannel INTEGER, sniBusDMATiming INTEGER, sniBusDMATransferSize INTEGER } sniDMABusType OBJECT-TYPE SYNTAX INTEGER { unknown(0), isa(2), eisa(3), pci(5) } ACCESS read-only STATUS mandatory DESCRIPTION "Type of the bus" ::= { sniDMAEntry 1 } sniDMABusIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Index of the bus based on 1" ::= { sniDMAEntry 2 } sniDMASlotDevice OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Slot or Device number based on 0" ::= { sniDMAEntry 3 } sniDMAFunctionNo OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Function number based on 1" ::= { sniDMAEntry 4 } sniDMANo OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "DMA number based on 1" ::= { sniDMAEntry 5 } sniBusDMAChannel OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "DMA channel " ::= { sniDMAEntry 6 } sniBusDMATiming OBJECT-TYPE SYNTAX INTEGER { other(1), default-timing(2), type-a-timing(3), type-b-timing(4) } ACCESS read-only STATUS mandatory DESCRIPTION "DMA timing" ::= { sniDMAEntry 7 } sniBusDMATransferSize OBJECT-TYPE SYNTAX INTEGER { other(1), bit-8(2), bit-16(3), bit-32(4) } ACCESS read-only STATUS mandatory DESCRIPTION "DMA transfer size" ::= { sniDMAEntry 8 } -- ---------------------------------------------------------------------------------------------- -- -- TABLE sniPortTable -- STATUS mandatory -- DESCRIPTION "Description of all bus I/O port information" -- -- sniPortTable: 1.3.6.1.4.1.231.2.10.2.2.4.4.4 -- -- ---------------------------------------------------------------------------------------------- sniPortTable OBJECT-TYPE SYNTAX SEQUENCE OF SniPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of all port entries" ::= { sniBusResource 4 } sniPortEntry OBJECT-TYPE SYNTAX SniPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " " INDEX { sniPortBusType, sniPortBusIndex, sniPortSlotDevice, sniPortFunctionNo, sniPortNo } ::= { sniPortTable 1 } SniPortEntry ::= SEQUENCE { sniPortBusType INTEGER, sniPortBusIndex INTEGER, sniPortSlotDevice INTEGER, sniPortFunctionNo INTEGER, sniPortNo INTEGER, sniBusIOFirstPort INTEGER, sniBusIONoOfPorts INTEGER, sniBusIOPortShared INTEGER } sniPortBusType OBJECT-TYPE SYNTAX INTEGER { unknown(0), isa(2), eisa(3), pci(5) } ACCESS read-only STATUS mandatory DESCRIPTION "Type of the bus" ::= { sniPortEntry 1 } sniPortBusIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Index of the bus based on 1" ::= { sniPortEntry 2 } sniPortSlotDevice OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Slot or Device number based on 0" ::= { sniPortEntry 3 } sniPortFunctionNo OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Function number based on 1" ::= { sniPortEntry 4 } sniPortNo OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Port number based on 1" ::= { sniPortEntry 5 } sniBusIOFirstPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "First io port used" ::= { sniPortEntry 6 } sniBusIONoOfPorts OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of io ports used" ::= { sniPortEntry 7 } sniBusIOPortShared OBJECT-TYPE SYNTAX INTEGER { true(1), false(2), unknown(3) } ACCESS read-only STATUS mandatory DESCRIPTION "True if io port is shared" ::= { sniPortEntry 8 } -- ********************************************************************************************** -- -- GROUP sniBusSummary -- DESCRIPTION "This group describes an overview over all bus components at all buses" -- Implementation of this group is optional -- -- sniBusSummary group: 1.3.6.1.4.1.231.2.10.2.2.4.5 -- -- ********************************************************************************************** -- ---------------------------------------------------------------------------------------------- -- -- TABLE sniBusComponentTable -- STATUS mandatory -- DESCRIPTION "Description of all bus I/O port information" -- -- sniBusComponentTable: 1.3.6.1.4.1.231.2.10.2.2.4.5.1 -- -- ---------------------------------------------------------------------------------------------- sniBusComponentTable OBJECT-TYPE SYNTAX SEQUENCE OF SniBusComponents ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of all common data for all functions" ::= { sniBusSummary 1 } sniBusComponents OBJECT-TYPE SYNTAX SniBusComponents ACCESS not-accessible STATUS mandatory DESCRIPTION " " INDEX { sniBusCompBusType, sniBusCompBusNumber, sniBusCompDeviceNo } ::= { sniBusComponentTable 1 } SniBusComponents ::= SEQUENCE { sniBusCompBusType INTEGER, sniBusCompBusNumber INTEGER, sniBusCompDeviceNo INTEGER, sniBusCompSlotNo INTEGER, sniBusCompDeviceName DisplayString, sniBusCompDeviceType DisplayString, sniBusCompEisaPciId DisplayString } sniBusCompBusType OBJECT-TYPE SYNTAX INTEGER { unknown(1), isa(2), eisa(3), pci(5) } ACCESS read-only STATUS mandatory DESCRIPTION "Type of the bus (ISA, EISA, PCI)" ::= { sniBusComponents 1 } sniBusCompBusNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Bus number for the specified bus type (1..n)" ::= { sniBusComponents 2 } sniBusCompDeviceNo OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Device number (PCI) or slot number (ISA, EISA)" ::= { sniBusComponents 3 } sniBusCompSlotNo OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Physical slot number (0..n), -1 if unknown" ::= { sniBusComponents 4 } sniBusCompDeviceName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Vendor and device name in readable form" ::= { sniBusComponents 5 } sniBusCompDeviceType OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Device type in readable form" ::= { sniBusComponents 6 } sniBusCompEisaPciId OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "EISA ID for EISA components, PCI vendor/device ID for PCI components (hexadecimal notation)" ::= { sniBusComponents 7 } -- ********************************************************************************************** -- -- GROUP svBusPciEx -- DESCRIPTION "This group describes all PCI bus components and functions (with PCI segment support)" -- Implementation of this group is optional -- -- svBusPciEx group: 1.3.6.1.4.1.231.2.10.2.2.4.6 -- -- ********************************************************************************************** -- ---------------------------------------------------------------------------------------------- -- -- TABLE svPciFunctionTable -- STATUS mandatory -- DESCRIPTION "Description of all PCI bus functions (with PCI segment support)" -- -- sniPciFunctionTable: 1.3.6.1.4.1.231.2.10.2.2.4.6.1 -- -- ---------------------------------------------------------------------------------------------- svPciFunctionTable OBJECT-TYPE SYNTAX SEQUENCE OF SvPciFunctionEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of all pci function entries" ::= { svBusPciEx 1 } svPciFunctionEntry OBJECT-TYPE SYNTAX SvPciFunctionEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " " INDEX { svPciSegmentNo, svPciBusIndex, svPciDeviceNo, svPciFunctionNo } ::= { svPciFunctionTable 1 } SvPciFunctionEntry ::= SEQUENCE { svPciSegmentNo INTEGER, svPciBusIndex INTEGER, svPciDeviceNo INTEGER, svPciFunctionNo INTEGER, svPciVendorId INTEGER, svPciDeviceId INTEGER, svPciRevisionId INTEGER, svPciBaseClass INTEGER, svPciSubClass INTEGER, svPciProgIf INTEGER, svPciBuiltInSelfTest INTEGER, svPciInterruptPin INTEGER, svPciInterruptLine INTEGER, svPciSpecificData OCTET STRING, svPciSecondaryBusIndex INTEGER, svPciSecondaryBusType INTEGER, svPciSubDeviceId INTEGER, svPciSubVendorId INTEGER, svPciVendorName DisplayString, svPciSubVendorName DisplayString, svPciDeviceName DisplayString, svPciAdapterUniqueId OCTET STRING, svPciAdapterSpecificData OCTET STRING, svPciPhysicalSlotDesignation DisplayString, svPciCompLocationKey OCTET STRING } svPciSegmentNo OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "PCI segment number (zero based)" ::= { svPciFunctionEntry 1 } svPciBusIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Index of the bus based on 1" ::= { svPciFunctionEntry 2 } svPciDeviceNo OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Device number based on 0" ::= { svPciFunctionEntry 3 } svPciFunctionNo OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Function number based on 1" ::= { svPciFunctionEntry 4 } svPciVendorId OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Identifies the manufacturer of the device. This must be a value allocated by the PCI SIG." ::= { svPciFunctionEntry 5 } svPciSubVendorId OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Identifies the particular device. This value is assigned by the manufacturer." ::= { svPciFunctionEntry 6 } svPciDeviceId OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Identifies the particular device. This value is assigned by the manufacturer." ::= { svPciFunctionEntry 7} svPciSubDeviceId OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Identifies the particular device. This value is assigned by the manufacturer." ::= { svPciFunctionEntry 8 } svPciRevisionId OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Specifies the revision level of the device described by svPciDeviceId. This value is assigned by the manufacturer." ::= { svPciFunctionEntry 9 } svPciBaseClass OBJECT-TYPE SYNTAX INTEGER { old-type-device(0), mass-storage-controller(1), network-controller(2), display-controller(3), multimedia-device(4), memory-controller(5), bridge-device(6), simple-communication-controller(7), base-system-peripheral(8), input-device(9), docking-station(10), processor(11), serial-bus-controller(12), wireless-controller(13), io-controller(14), satellite-communication-controller(15), encryption-device(16), signal-processor(17), unknown-device(255) } ACCESS read-only STATUS mandatory DESCRIPTION "Identifies type of the device, according to the PCI classification scheme." ::= { svPciFunctionEntry 10 } svPciSubClass OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Identifies the subtype, if any, of the device, according to the PCI classification scheme." ::= { svPciFunctionEntry 11 } svPciProgIf OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Identifies the register-level programming interface, if any, for the device, according to the PCI classification scheme." ::= { svPciFunctionEntry 12 } svPciBuiltInSelfTest OBJECT-TYPE SYNTAX INTEGER { built-in(1), not-built-in(2), unknown(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates if the device does support built-in self test." ::= { svPciFunctionEntry 13 } svPciInterruptPin OBJECT-TYPE SYNTAX INTEGER { not-implemented(0), inta(1), intb(2), intc(3), intd(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates which interrupt pin the PCI device uses." ::= { svPciFunctionEntry 14 } svPciInterruptLine OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the input of the system interrupt controller that the interrupt pin is connected to." ::= { svPciFunctionEntry 15 } svPciSpecificData OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "This is device specific data found in the COMMON CONFIGURATION SPACE. This field is currently not used and therefor filled with zeros." ::= { svPciFunctionEntry 16 } svPciSecondaryBusIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Valid only for a bridge device. This is the index of the bridge's secondary bus (-1 = no bus index available; ignore this field)." ::= { svPciFunctionEntry 17 } svPciSecondaryBusType OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Valid only for a bridge device. This is the type of the bridge's secondary bus. Following values are defined (according to PCI Local bus specification, Revision 2.1, values are incremented by 1): 00h: Unknown value; ignore this field 01h: Host bridge (bridge to CPU bus) 02h: ISA bridge 03h: EISA bridge 04h: MCA bridge 05h: PCI-to-PCI bridge 06h: PCMCIA bridge 07h: NuBus bridge 80h: Other bridge device" ::= { svPciFunctionEntry 18 } svPciVendorName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "PCI device vendor name" ::= { svPciFunctionEntry 19 } svPciSubVendorName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "PCI device sub vendor name" ::= { svPciFunctionEntry 20 } svPciDeviceName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Operating system independent name of device in readable form" ::= { svPciFunctionEntry 21 } svPciAdapterUniqueId OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Unigue adapter type specific ID. MAC address for lan adapters. WWN for fibre channel adapters. Otherwise empty." ::= { svPciFunctionEntry 22 } svPciAdapterSpecificData OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Specific data for this adapter." ::= { svPciFunctionEntry 23 } svPciPhysicalSlotDesignation OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Designation of the physical slot where the device is plugged in" ::= { svPciFunctionEntry 24 } svPciCompLocationKey OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Unique device location key, used for identifying the component; e.g. 'TYPE_PCI&BUS_3&DEV_14&FUNC_0' or 'TYPE_PCI&BUS_3&DEV_14&FUNC_0&SEG_1'" ::= { svPciFunctionEntry 25 } END