-- Version 2.15.1.1, modified 2001-05-31 17:28:36-04 SDLC-OPT-MIB DEFINITIONS ::= BEGIN IMPORTS mgmt, NetworkAddress, IpAddress, Counter, Gauge, TimeTicks, enterprises FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212; -- Codex MIB Group definitions codex OBJECT IDENTIFIER ::= { enterprises 449 } cdxProductSpecific OBJECT IDENTIFIER ::= { codex 2 } cdx6500 OBJECT IDENTIFIER ::= { cdxProductSpecific 1 } cdx6500Configuration OBJECT IDENTIFIER ::= { cdx6500 2 } cdx6500CfgProtocolGroup OBJECT IDENTIFIER ::= { cdx6500Configuration 1 } cdx6500PCTPortProtocolGroup OBJECT IDENTIFIER ::= { cdx6500CfgProtocolGroup 1 } cdx6500PCTStationProtocolGroup OBJECT IDENTIFIER ::= { cdx6500CfgProtocolGroup 3 } cdx6500Statistics OBJECT IDENTIFIER ::= { cdx6500 3 } cdx6500StatProtocolGroup OBJECT IDENTIFIER ::= { cdx6500Statistics 1 } cdx6500PSTPortProtocolGroup OBJECT IDENTIFIER ::= { cdx6500StatProtocolGroup 1 } cdx6500PSTStationProtocolGroup OBJECT IDENTIFIER ::= { cdx6500StatProtocolGroup 3 } cdx6500Controls OBJECT IDENTIFIER ::= { cdx6500 4 } cdx6500ContSDLC OBJECT IDENTIFIER ::= { cdx6500Controls 5 } -- Textual conventions Counter16 ::= INTEGER (0..65535) DisplayString ::= OCTET STRING -- This data type is used to model textual information taken -- from the NVT ASCII character set. By convention, objects -- with this syntax are declared as having SIZE (0..255) -- The SDLC Port Configuration Table -- This table contains Configuration paramaters -- for the SDLC Port table. cdx6500PCTSDLCPortTable OBJECT-TYPE SYNTAX SEQUENCE OF Cdx6500PCTSDLCPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "All of the configuration parameters relevant to the SDLC Port table." ::= { cdx6500PCTPortProtocolGroup 12 } cdx6500PCTSDLCPortEntry OBJECT-TYPE SYNTAX Cdx6500PCTSDLCPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A row of SDLC Port configuration parameters." INDEX { cdx6500sdlcpCfgPortNum } ::= { cdx6500PCTSDLCPortTable 1 } Cdx6500PCTSDLCPortEntry ::= SEQUENCE { cdx6500sdlcpCfgPortNum INTEGER, cdx6500sdlcpSubType INTEGER, cdx6500sdlcpTxCoding INTEGER, cdx6500sdlcpLineType INTEGER, cdx6500sdlcpTxType INTEGER, cdx6500sdlcpSendSigDelay INTEGER, cdx6500sdlcpClock INTEGER, cdx6500sdlcpClockSpeed INTEGER, cdx6500sdlcpNumControllers INTEGER, cdx6500sdlcpPollTimer INTEGER, cdx6500sdlcpPollFrequency INTEGER, cdx6500sdlcpTries INTEGER, cdx6500sdlcpOptions DisplayString, cdx6500sdlcpPortAddress DisplayString, cdx6500sdlcpPortOptions DisplayString, cdx6500sdlcpHPADResponseDelay INTEGER, cdx6500sdlcpMaxFrameSize INTEGER, cdx6500sdlcpRtsCtsDelay INTEGER, cdx6500sdlcpElectricalInterfaceType INTEGER, cdx6500sdlcpV24ElectricalInterfaceOption INTEGER, cdx6500sdlcpHighSpeedElectricalInterfaceOption INTEGER } cdx6500sdlcpCfgPortNum OBJECT-TYPE SYNTAX INTEGER (1..54) ACCESS read-only STATUS mandatory DESCRIPTION "Specifies a specific port (physical port number) in the node." ::= { cdx6500PCTSDLCPortEntry 1 } cdx6500sdlcpSubType OBJECT-TYPE SYNTAX INTEGER { hpad (0), tpad (1), newvalHpad (50) } ACCESS read-only STATUS mandatory DESCRIPTION "This is the SDLC port subtype hpad - Host PAD. tpad - Terminal PAD. newvalHpad - same functionality as 'hpad', new enumeration added for RFC1155 compatibility." ::= { cdx6500PCTSDLCPortEntry 2 } cdx6500sdlcpTxCoding OBJECT-TYPE SYNTAX INTEGER { nrz (0), nrzi (1), newvalNrz (50) } ACCESS read-only STATUS mandatory DESCRIPTION "This is the data encoding used on the SDLC link. nrz - Non Return to Zero nrzi - Non Return to Zero Inverted newvalNrz - same functionality as 'nrz', new enumeration added for RFC1155 compatibility." ::= { cdx6500PCTSDLCPortEntry 3 } cdx6500sdlcpLineType OBJECT-TYPE SYNTAX INTEGER { hdx (0), fdx (1), hdxdce (2), newvalHdx (50) } ACCESS read-only STATUS mandatory DESCRIPTION "Type of line, indicates whether half duplex or full duplex signals are being generated. fdx - communications occuring in both directions simultaneously between devices. hdx - transmission occuring in both directions, but only one direction at a time. This operation is not currently supported. hdxdce - (Half Duplex DCE) This is used on the HPAD when the port is a DCE and the port is interfacing directly to a FEP. The port detects RTS go HIGH, waits RTS TO CTS DELAY ms, and raises CTS. newvalHdx - same functionality as 'hdx', new enumeration added for RFC1155 compatibility." ::= { cdx6500PCTSDLCPortEntry 4 } cdx6500sdlcpTxType OBJECT-TYPE SYNTAX INTEGER { tws (0), twa (1), newvalTws (50) } ACCESS read-only STATUS mandatory DESCRIPTION "This is the transmission mode used on the line. tws - Two way Simultaneout. twa - Two Way Alternate used by most controllers. newvalTws - same functionality as 'tws', new enumeration added for RFC1155 compatibility." ::= { cdx6500PCTSDLCPortEntry 5 } cdx6500sdlcpSendSigDelay OBJECT-TYPE SYNTAX INTEGER { deprecatedObj (1) } ACCESS read-only STATUS deprecated DESCRIPTION "This object is replaced by cdx6500sdlcpHPADResponseDelay. This is a configurable delay that defines the amount of time that the HPAD delays before sending a response to the HOST. The delay is specified in milliseconds." ::= { cdx6500PCTSDLCPortEntry 6 } cdx6500sdlcpClock OBJECT-TYPE SYNTAX INTEGER { int (0), ext (1), newvalInt (50) } ACCESS read-only STATUS mandatory DESCRIPTION "int - Internal clock source. ext - External clock source. newvalInt - same functionality as 'int', new enumeration added for RFC1155 compatibility." ::= { cdx6500PCTSDLCPortEntry 7 } cdx6500sdlcpClockSpeed OBJECT-TYPE SYNTAX INTEGER (1200..80000) ACCESS read-only STATUS mandatory DESCRIPTION "This is the speed of the port in bits per second, when using internal clocking." ::= { cdx6500PCTSDLCPortEntry 8 } cdx6500sdlcpNumControllers OBJECT-TYPE SYNTAX INTEGER (1..32) ACCESS read-only STATUS mandatory DESCRIPTION "This is the number of controllers (PU TYPE 1 or PU TYPE 2 devices) on the SDLC line." ::= { cdx6500PCTSDLCPortEntry 9 } cdx6500sdlcpPollTimer OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "Worst case delay for a slave to respond to a poll frame sent by the master, including modem turn around time, etc. Value in 10ths of second ( 30 = 3.0 seconds )." ::= { cdx6500PCTSDLCPortEntry 10 } cdx6500sdlcpPollFrequency OBJECT-TYPE SYNTAX INTEGER (50..250) ACCESS read-only STATUS mandatory DESCRIPTION "Time in milliseconds between polls when no data is exchanged." ::= { cdx6500PCTSDLCPortEntry 11 } cdx6500sdlcpTries OBJECT-TYPE SYNTAX INTEGER (1..16) ACCESS read-only STATUS mandatory DESCRIPTION "Maximum number of attempts to complete a transmission." ::= { cdx6500PCTSDLCPortEntry 12 } cdx6500sdlcpOptions OBJECT-TYPE SYNTAX DisplayString (SIZE(3..5)) ACCESS read-only STATUS mandatory DESCRIPTION "Select options on this SDLC port as follows: NONE - no option specified MARKi - port uses mark idle between frame exchanges (Required by System 36 - AS/400 series) DMs - HPAD does not send DM in response to SNRM/XID received from host. After call is accepted and TPAD responds with QUA/QXID, HPAD will send UA/XID. DISCs - TPAD sends a DISC frame when station goes down. The DISC may be retransmitted up to Tries times, if the Cluster Controller does not respond, before sending a SNRM. FFBF - TPAD sends a broadcast XID. If the number of controllers configured is equal to 1 and the associated QLLC station table option is not XIDs the TPAD will poll with a broadcast address until a secondary station response address is received." ::= { cdx6500PCTSDLCPortEntry 13 } cdx6500sdlcpPortAddress OBJECT-TYPE SYNTAX DisplayString (SIZE(0..15)) ACCESS read-only STATUS mandatory DESCRIPTION "When an SDLC port makes a call, this address is inserted into the calling address field." ::= { cdx6500PCTSDLCPortEntry 14 } cdx6500sdlcpPortOptions OBJECT-TYPE SYNTAX DisplayString (SIZE(2..4)) ACCESS read-only STATUS mandatory DESCRIPTION "Specify any of the following port control options: NONE - no option specified MB - raise Pin 22 when the port becomes disabled" ::= { cdx6500PCTSDLCPortEntry 15 } cdx6500sdlcpHPADResponseDelay OBJECT-TYPE SYNTAX INTEGER { msec0 (0), msec50 (51), msec100 (100), msec150 (150), msec200 (200), newvalMsec0 (50) } ACCESS read-only STATUS mandatory DESCRIPTION "This object replaces cdx6500sdlcpSendSigDelay. This is a configurable delay that defines the amount of time that the HPAD delays before sending a response to the HOST. The delay is specified in milliseconds. newvalMsec0 : same functionality as 'msec0', new enumeration added for RFC1155 compatibility." ::= { cdx6500PCTSDLCPortEntry 16 } cdx6500sdlcpMaxFrameSize OBJECT-TYPE SYNTAX INTEGER (1..4096) ACCESS read-only STATUS mandatory DESCRIPTION "Maximum size (in bytes) of a frame, excluding the frame header and CRC." ::= { cdx6500PCTSDLCPortEntry 17 } cdx6500sdlcpRtsCtsDelay OBJECT-TYPE SYNTAX INTEGER (0..250) ACCESS read-only STATUS mandatory DESCRIPTION "Delay in milliseconds that the HDX DCE TPAD or the HDXDCE HPAD waits from the time it detects RTS go HIGH until the time it raises CTS. It is accurate to +/- 2 milliseconds." ::= { cdx6500PCTSDLCPortEntry 18 } cdx6500sdlcpElectricalInterfaceType OBJECT-TYPE SYNTAX INTEGER { v24 (1), v35 (2), v36 (3), x21 (4), none (5) } ACCESS read-only STATUS mandatory DESCRIPTION "Specify the Electrical Interface Type: V.24 - V.24 Electrical Interface Type V.35 - V.35 Electrical Interface Type V.36 - V.36 Electrical Interface Type X.21 - X.21 Electrical Interface Type NONE - Electrically disabled" ::= { cdx6500PCTSDLCPortEntry 19 } cdx6500sdlcpV24ElectricalInterfaceOption OBJECT-TYPE SYNTAX INTEGER { ri (1), tm (2) } ACCESS read-only STATUS mandatory DESCRIPTION "Specify the Pin 22 option: RI - V.24 uses Pin 22 for Ring Indicator output signal TM - V.24 uses Pin 22 for Test Mode input signal" ::= { cdx6500PCTSDLCPortEntry 20 } cdx6500sdlcpHighSpeedElectricalInterfaceOption OBJECT-TYPE SYNTAX INTEGER { none (1), xover (2) } ACCESS read-only STATUS mandatory DESCRIPTION "Specify the cable type: NONE - V.35/V.36/X.21 DCE with straight through cable XOVER - V.35/V.36/X.21 DCE with crossover adapter cable" ::= { cdx6500PCTSDLCPortEntry 21 } -- The SDLC Port Statistics Table -- This table contains Statistics paramaters -- for the SDLC Port table. cdx6500PPSTSDLCPortTable OBJECT-TYPE SYNTAX SEQUENCE OF Cdx6500PPSTSDLCPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "All of the statistics parameters relevant to the SDLC Port table." ::= { cdx6500PSTPortProtocolGroup 12 } cdx6500PPSTSDLCPortEntry OBJECT-TYPE SYNTAX Cdx6500PPSTSDLCPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A row of SDLC Port statistics parameters." INDEX { cdx6500sdlcpStatsPortNum } ::= { cdx6500PPSTSDLCPortTable 1 } Cdx6500PPSTSDLCPortEntry ::= SEQUENCE { cdx6500sdlcpStatsPortNum INTEGER, cdx6500sdlcpPortStatus INTEGER, cdx6500sdlcpPortSpeed INTEGER, cdx6500sdlcpCharInTotal Counter, cdx6500sdlcpCharOutTotal Counter, cdx6500sdlcpCharsInPerSec INTEGER, cdx6500sdlcpCharsOutPerSec INTEGER, cdx6500sdlcpFrameInTotal Counter, cdx6500sdlcpFrameOutTotal Counter, cdx6500sdlcpFramesInPerSec INTEGER, cdx6500sdlcpFramesOutPerSec INTEGER, cdx6500sdlcpStateChange DisplayString, cdx6500sdlcpLinkDowns Counter16, cdx6500sdlcpUtilizationIn INTEGER, cdx6500sdlcpUtilizationOut INTEGER, cdx6500sdlcpOverrunErrors Counter16, cdx6500sdlcpUnderrunErrors Counter16, cdx6500sdlcpCRCErrors Counter16, cdx6500sdlcpPacketsQueued INTEGER, cdx6500sdlcpRRInFrames Counter, cdx6500sdlcpRROutFrames Counter, cdx6500sdlcpRNRInFrames Counter, cdx6500sdlcpRNROutFrames Counter, cdx6500sdlcpSNRMInFrames Counter, cdx6500sdlcpSNRMOutFrames Counter, cdx6500sdlcpUAInFrames Counter, cdx6500sdlcpUAOutFrames Counter, cdx6500sdlcpDMInFrames Counter, cdx6500sdlcpDMOutFrames Counter, cdx6500sdlcpXIDInFrames Counter, cdx6500sdlcpXIDOutFrames Counter, cdx6500sdlcpREJInFrames Counter, cdx6500sdlcpREJOutFrames Counter, cdx6500sdlcpDISCInFrames Counter, cdx6500sdlcpDISCOutFrames Counter, cdx6500sdlcpRDInFrames Counter, cdx6500sdlcpRDOutFrames Counter, cdx6500sdlcpFRMRInFrames Counter, cdx6500sdlcpFRMROutFrames Counter, cdx6500sdlcpUPInFrames Counter, cdx6500sdlcpUPOutFrames Counter, cdx6500sdlcpTESTInFrames Counter, cdx6500sdlcpTESTOutFrames Counter, cdx6500sdlcpXIDNullInFrames Counter, cdx6500sdlcpXIDNullOutFrames Counter, cdx6500sdlcpXID0InFrames Counter, cdx6500sdlcpXID0OutFrames Counter, cdx6500sdlcpXID1InFrames Counter, cdx6500sdlcpXID1OutFrames Counter, cdx6500sdlcpXID3InFrames Counter, cdx6500sdlcpXID3OutFrames Counter } cdx6500sdlcpStatsPortNum OBJECT-TYPE SYNTAX INTEGER (1..54) ACCESS read-only STATUS mandatory DESCRIPTION "Specifies a specific port (physical port number) in the node." ::= { cdx6500PPSTSDLCPortEntry 1 } cdx6500sdlcpPortStatus OBJECT-TYPE SYNTAX INTEGER { disabled (0), enabled (1), busyout (2), up (3), down (4), newvaldisabled (50) } ACCESS read-only STATUS mandatory DESCRIPTION "Specifies the current port status. up : At least one station is responding to polls. down : None of the stattions are responding to polls. disabled : The port is disabled by the user. newvalDisabled : same functionality as 'disabled', new enumeration added for RFc1155 compatibility." ::= { cdx6500PPSTSDLCPortEntry 2 } cdx6500sdlcpPortSpeed OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The measured port speed in bits per second." ::= { cdx6500PPSTSDLCPortEntry 3 } cdx6500sdlcpCharInTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of characters received until now, not including all SDLC header characters." ::= { cdx6500PPSTSDLCPortEntry 4 } cdx6500sdlcpCharOutTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of characters transmitted until now, not including all SDLC header characters." ::= { cdx6500PPSTSDLCPortEntry 5 } cdx6500sdlcpCharsInPerSec OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The average number of characters received per second during the previous minute." ::= { cdx6500PPSTSDLCPortEntry 6 } cdx6500sdlcpCharsOutPerSec OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The average number of characters transmitted per second during the previous minute." ::= { cdx6500PPSTSDLCPortEntry 7 } cdx6500sdlcpFrameInTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of SDLC frames received until now." ::= { cdx6500PPSTSDLCPortEntry 8 } cdx6500sdlcpFrameOutTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of SDLC frames transmitted until now." ::= { cdx6500PPSTSDLCPortEntry 9 } cdx6500sdlcpFramesInPerSec OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The average number of frames received per second during the previous minute." ::= { cdx6500PPSTSDLCPortEntry 10 } cdx6500sdlcpFramesOutPerSec OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The average number of frames transmitted per second during the previous minute." ::= { cdx6500PPSTSDLCPortEntry 11 } cdx6500sdlcpStateChange OBJECT-TYPE SYNTAX DisplayString (SIZE(0..20)) ACCESS read-only STATUS mandatory DESCRIPTION "The date and time when the link entered the current state." ::= { cdx6500PPSTSDLCPortEntry 12 } cdx6500sdlcpLinkDowns OBJECT-TYPE SYNTAX Counter16 ACCESS read-only STATUS mandatory DESCRIPTION "Total number of times link has made a transition from the UP state to the DOWN state." ::= { cdx6500PPSTSDLCPortEntry 13 } cdx6500sdlcpUtilizationIn OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicates a percentage of the link resources currently in use in the IN(from the line to the port) direction." ::= { cdx6500PPSTSDLCPortEntry 14 } cdx6500sdlcpUtilizationOut OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicates a percentage of the link resources currently in use in the OUT(from the port to the line) direction." ::= { cdx6500PPSTSDLCPortEntry 15 } cdx6500sdlcpOverrunErrors OBJECT-TYPE SYNTAX Counter16 ACCESS read-only STATUS mandatory DESCRIPTION "Total number of overrun errors counted by the I/O driver. Overrun errors occur when received data is lost because it cannot be processed by the CPU." ::= { cdx6500PPSTSDLCPortEntry 16 } cdx6500sdlcpUnderrunErrors OBJECT-TYPE SYNTAX Counter16 ACCESS read-only STATUS mandatory DESCRIPTION "Total number of underrun errors counted by the I/O driver. Underrun errors occur when the transmission of a frame cannot be completed because of momentary CPU overload." ::= { cdx6500PPSTSDLCPortEntry 17 } cdx6500sdlcpCRCErrors OBJECT-TYPE SYNTAX Counter16 ACCESS read-only STATUS mandatory DESCRIPTION "Total number of CRC errors counted by the I/O driver." ::= { cdx6500PPSTSDLCPortEntry 18 } cdx6500sdlcpPacketsQueued OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Total number of packets queued at the SDLC protocol layer by the transmitter." ::= { cdx6500PPSTSDLCPortEntry 19 } cdx6500sdlcpRRInFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of RR frames received until the present time." ::= { cdx6500PPSTSDLCPortEntry 20 } cdx6500sdlcpRROutFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of RR frames transmitted until the present time." ::= { cdx6500PPSTSDLCPortEntry 21 } cdx6500sdlcpRNRInFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of RNR frames received until the present time." ::= { cdx6500PPSTSDLCPortEntry 22 } cdx6500sdlcpRNROutFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of RNR frames transmitted until the present time." ::= { cdx6500PPSTSDLCPortEntry 23 } cdx6500sdlcpSNRMInFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of SNRM frames received until the present time." ::= { cdx6500PPSTSDLCPortEntry 24 } cdx6500sdlcpSNRMOutFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of SNRM frames transmitted until the present time." ::= { cdx6500PPSTSDLCPortEntry 25 } cdx6500sdlcpUAInFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of UA frames received until the present time." ::= { cdx6500PPSTSDLCPortEntry 26 } cdx6500sdlcpUAOutFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of UA frames transmitted until the present time." ::= { cdx6500PPSTSDLCPortEntry 27 } cdx6500sdlcpDMInFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of DM frames received until the present time." ::= { cdx6500PPSTSDLCPortEntry 28 } cdx6500sdlcpDMOutFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of DM frames transmitted until the present time." ::= { cdx6500PPSTSDLCPortEntry 29 } cdx6500sdlcpXIDInFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of XID frames received until the present time." ::= { cdx6500PPSTSDLCPortEntry 30 } cdx6500sdlcpXIDOutFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of XID frames transmitted until the present time." ::= { cdx6500PPSTSDLCPortEntry 31 } cdx6500sdlcpREJInFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of REJ frames received until the present time." ::= { cdx6500PPSTSDLCPortEntry 32 } cdx6500sdlcpREJOutFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of REJ frames transmitted until the present time." ::= { cdx6500PPSTSDLCPortEntry 33 } cdx6500sdlcpDISCInFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of DISC frames received until the present time." ::= { cdx6500PPSTSDLCPortEntry 34 } cdx6500sdlcpDISCOutFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of DISC frames transmitted until the present time." ::= { cdx6500PPSTSDLCPortEntry 35 } cdx6500sdlcpRDInFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of RD frames received until the present time." ::= { cdx6500PPSTSDLCPortEntry 36 } cdx6500sdlcpRDOutFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of RD frames transmitted until the present time." ::= { cdx6500PPSTSDLCPortEntry 37 } cdx6500sdlcpFRMRInFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of FRMR frames received until the present time." ::= { cdx6500PPSTSDLCPortEntry 38 } cdx6500sdlcpFRMROutFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of FRMR frames transmitted until the present time." ::= { cdx6500PPSTSDLCPortEntry 39 } cdx6500sdlcpUPInFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of UP frames received until the present time." ::= { cdx6500PPSTSDLCPortEntry 40 } cdx6500sdlcpUPOutFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of UP frames transmitted until the present time." ::= { cdx6500PPSTSDLCPortEntry 41 } cdx6500sdlcpTESTInFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of TEST frames received until the present time." ::= { cdx6500PPSTSDLCPortEntry 42 } cdx6500sdlcpTESTOutFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of TEST frames transmitted until the present time." ::= { cdx6500PPSTSDLCPortEntry 43 } cdx6500sdlcpXIDNullInFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of XID Null frames received until the present time." ::= { cdx6500PPSTSDLCPortEntry 44 } cdx6500sdlcpXIDNullOutFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of XID Null frames transmitted until the present time." ::= { cdx6500PPSTSDLCPortEntry 45 } cdx6500sdlcpXID0InFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of XID Type 0 frames received until the present time." ::= { cdx6500PPSTSDLCPortEntry 46 } cdx6500sdlcpXID0OutFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of XID Type 0 frames transmitted until the present time." ::= { cdx6500PPSTSDLCPortEntry 47 } cdx6500sdlcpXID1InFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of XID Type 1 frames received until the present time." ::= { cdx6500PPSTSDLCPortEntry 48 } cdx6500sdlcpXID1OutFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of XID Type 1 frames transmitted until the present time." ::= { cdx6500PPSTSDLCPortEntry 49 } cdx6500sdlcpXID3InFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of XID Type 3 frames received until the present time." ::= { cdx6500PPSTSDLCPortEntry 50 } cdx6500sdlcpXID3OutFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of XID Type 3 frames transmitted until the present time." ::= { cdx6500PPSTSDLCPortEntry 51 } -- The SDLC Station Configuration Table -- This table contains Configuration paramaters -- for the SDLC Station table. cdx6500SPCTSDLCStationTable OBJECT-TYPE SYNTAX SEQUENCE OF Cdx6500SPCTSDLCStationEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "All of the configuration parameters relevant to the SDLC Station table." ::= { cdx6500PCTStationProtocolGroup 4 } cdx6500SPCTSDLCStationEntry OBJECT-TYPE SYNTAX Cdx6500SPCTSDLCStationEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A row of SDLC station configuration parameters." INDEX { cdx6500sdlcsCfgPortNum, cdx6500sdlcsCfgStationNum } ::= { cdx6500SPCTSDLCStationTable 1 } Cdx6500SPCTSDLCStationEntry ::= SEQUENCE { cdx6500sdlcsCfgPortNum INTEGER, cdx6500sdlcsCfgStationNum INTEGER, cdx6500sdlcsStationAddr DisplayString, cdx6500sdlcsFrameWinSize INTEGER, cdx6500sdlcsAutocallMnem DisplayString, cdx6500sdlcsProtocolID DisplayString, cdx6500sdlcsCUG DisplayString, cdx6500sdlcsOptions DisplayString, cdx6500sdlcsStationID DisplayString, cdx6500sdlcsBillingFlag INTEGER, cdx6500sdlcsStnSubaddress DisplayString, cdx6500sdlcsGroupAddress DisplayString, cdx6500sdlcsX25Password DisplayString, cdx6500sdlcsProtectionLevel INTEGER, cdx6500sdlcsReconnectTimeout INTEGER, cdx6500sdlcsReconnectLimit INTEGER, cdx6500sdlcsTrafficPriority INTEGER, cdx6500sdlcsCallTimer INTEGER, cdx6500sdlcsIdleTimer INTEGER, cdx6500sdlcsVerConnTimer INTEGER, cdx6500sdlcsUnsusWaitTimer INTEGER, cdx6500sdlcsMaxCallAttempts INTEGER } cdx6500sdlcsCfgPortNum OBJECT-TYPE SYNTAX INTEGER (1..54) ACCESS read-only STATUS mandatory DESCRIPTION "Refers to the physical port number." ::= { cdx6500SPCTSDLCStationEntry 1 } cdx6500sdlcsCfgStationNum OBJECT-TYPE SYNTAX INTEGER (1..32) ACCESS read-only STATUS mandatory DESCRIPTION "The number of the controller on the multidrop line. Also used for routing purposes." ::= { cdx6500SPCTSDLCStationEntry 2 } cdx6500sdlcsStationAddr OBJECT-TYPE SYNTAX DisplayString (SIZE(0..2)) ACCESS read-only STATUS mandatory DESCRIPTION "The station address on the multidrop line." ::= { cdx6500SPCTSDLCStationEntry 3 } cdx6500sdlcsFrameWinSize OBJECT-TYPE SYNTAX INTEGER (1..7) ACCESS read-only STATUS mandatory DESCRIPTION "Frame level window size must be set to the same value in devices at each end of the link." ::= { cdx6500SPCTSDLCStationEntry 4 } cdx6500sdlcsAutocallMnem OBJECT-TYPE SYNTAX DisplayString (SIZE(0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "This mnemonic references the remote address which will be called when polling activity is detected on the sdlc line." ::= { cdx6500SPCTSDLCStationEntry 5 } cdx6500sdlcsProtocolID OBJECT-TYPE SYNTAX DisplayString (SIZE(0..8)) ACCESS read-only STATUS mandatory DESCRIPTION "The protocol identifier is the first four bytes of the call user data. If not configured the PAD will use C3000000 as the protocol ID in the call." ::= { cdx6500SPCTSDLCStationEntry 6 } cdx6500sdlcsCUG OBJECT-TYPE SYNTAX DisplayString (SIZE(23)) ACCESS read-only STATUS mandatory DESCRIPTION "The station may be a member of up to 8 different Closed User Groups (CUGs). Each CUG membership must be a two digit number (except --)and separated by a comma. (e.g. 12,34,56,09,02,03). -- - No CUG Membership 00-99 - CUG Membership" ::= { cdx6500SPCTSDLCStationEntry 7 } cdx6500sdlcsOptions OBJECT-TYPE SYNTAX DisplayString (SIZE(3..4)) ACCESS read-only STATUS mandatory DESCRIPTION "Select options on this SDLC station as follows: NONE - no option specified. CUG - check closed user group in incoming calls, and insert closed user group facility in outgoing calls. QRRs - HPAD sends QRR after QLLC link comes up XIDs - TPAD responds to QXIDs with XID configured for this station XIDs are not sent to the Cluster Controller. XID3 - HPAD and TPAD will pass XIDs transparently. This option should not be set if XIDs option is selected. Corresponding station options must be XID3. RNRs - TPAD initially polls with RNR until a data packet or an QRR is received by the QLLC station on the TPAD side. DFC - the station will wait the amount of time specified by the call timer before placing the first call." ::= { cdx6500SPCTSDLCStationEntry 8 } cdx6500sdlcsStationID OBJECT-TYPE SYNTAX DisplayString (SIZE(0..14)) ACCESS read-only STATUS mandatory DESCRIPTION "This is the identification sent by the TPAD in a response. to a QXID when XIDs are enabled in the QLLC Options." ::= { cdx6500SPCTSDLCStationEntry 9 } cdx6500sdlcsBillingFlag OBJECT-TYPE SYNTAX INTEGER { off (0), on (1), newvaloff (50) } ACCESS read-only STATUS mandatory DESCRIPTION "This controls whether billing (accounting) records will be created for calls on this port. off - Billing (accounting) records will not be created for calls on this port. on - Billing (accounting) records will be created for calls on this port. newvalOff - same functionality as 'off', new enumeration added for RFC1155 compatibility." ::= { cdx6500SPCTSDLCStationEntry 10 } cdx6500sdlcsStnSubaddress OBJECT-TYPE SYNTAX DisplayString (SIZE(0..3)) ACCESS read-only STATUS mandatory DESCRIPTION "The calling subaddress is appended to the port address to create the calling address in the autocall generated." ::= { cdx6500SPCTSDLCStationEntry 11 } cdx6500sdlcsGroupAddress OBJECT-TYPE SYNTAX DisplayString (SIZE(0..3)) ACCESS read-only STATUS mandatory DESCRIPTION "This is the address of the poll group to which this station belongs. Enter an address of 0x00 for no group membership." ::= { cdx6500SPCTSDLCStationEntry 12 } cdx6500sdlcsX25Password OBJECT-TYPE SYNTAX DisplayString (SIZE(1..24)) ACCESS read-only STATUS mandatory DESCRIPTION "Only TPAD initiated autocall packets shall use this feature. The X.25 Network Password which may be up to 12 bytes long is inserted in the CUD of the Call Request packet. Padding with spaces must be added as necessary. Configure the Protocol ID to C3 01 00 00." ::= { cdx6500SPCTSDLCStationEntry 13 } cdx6500sdlcsProtectionLevel OBJECT-TYPE SYNTAX INTEGER { none (0), cponly (1), fulldcp (2), newvalnone (50) } ACCESS read-only STATUS mandatory DESCRIPTION "This specifies the level of data or connection protection which will be applied to calls to or from this port. The actual level for a call will be negotiated to the lesser of this level and the level configured for the other end of the call. none - No protection. cpOnly - Connection protection only. fullDcp - Full data and connection protection. newvalNone - same functionality as 'none', new enumeration added for RFC1155 compatibility." ::= { cdx6500SPCTSDLCStationEntry 14 } cdx6500sdlcsReconnectTimeout OBJECT-TYPE SYNTAX INTEGER (1..128) ACCESS read-only STATUS mandatory DESCRIPTION "This specifies the number of seconds that DCP on the originating side will wait between reconnection attempts." ::= { cdx6500SPCTSDLCStationEntry 15 } cdx6500sdlcsReconnectLimit OBJECT-TYPE SYNTAX INTEGER (0..127) ACCESS read-only STATUS mandatory DESCRIPTION "This specifies the number of times that DCP on the originating side will attempt to reconnect before clearing the call. If 0 is entered, it will not attempt to reconnect." ::= { cdx6500SPCTSDLCStationEntry 16 } cdx6500sdlcsTrafficPriority OBJECT-TYPE SYNTAX INTEGER { lowpriority (0), medpriority (1), hipriority (2), xppriority (3), newvallowpriority (50) } ACCESS read-only STATUS optional DESCRIPTION "This is the traffic priority of the SDLC station; low, medium, high, or expedite. newvalLowPriority : same functionality as 'lowPriority', new enumeration added for RFC1155 compatibility." ::= { cdx6500SPCTSDLCStationEntry 17 } cdx6500sdlcsCallTimer OBJECT-TYPE SYNTAX INTEGER (0..300) ACCESS read-only STATUS mandatory DESCRIPTION "This specifies the time before the next call is made. If 0 is entered, the time to the next call is handled internally. The time is in seconds." ::= { cdx6500SPCTSDLCStationEntry 18 } cdx6500sdlcsIdleTimer OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-only STATUS mandatory DESCRIPTION "The Link Idle Timer is used by the SNA Dial on Demand feature for determining how long the station should wait for a data frame before bringing the X.25 call down. If a 0 is entered, the call will never be brought down. The time is in seconds." ::= { cdx6500SPCTSDLCStationEntry 19 } cdx6500sdlcsVerConnTimer OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-only STATUS mandatory DESCRIPTION "The Verify Connection Timer is used by the SNA Dial on Demand feature for periodically verifying that the connection to the remote station is still active, after the link has been suspended. The timer specifies how long the the station waits before verifying the connection. If a 0 is entered, the connection will never be verified. The time is in seconds." ::= { cdx6500SPCTSDLCStationEntry 20 } cdx6500sdlcsUnsusWaitTimer OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-only STATUS mandatory DESCRIPTION "The Unsuspend Wait Timer is used by the SNA Dial on Demand feature for determining how long the station will wait in LINK-UNSUSPENDING state after receiving a call request before bringing the station down. If a 0 is entered, the station waits in LINK-UNSUSPENDED state forever. Time is in seconds." ::= { cdx6500SPCTSDLCStationEntry 21 } cdx6500sdlcsMaxCallAttempts OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "The Max Call Attempts is used to specify the number of times that the SDLC stations will attempt to autocall a remote destination. A value of zero will allow unlimited attempts." ::= { cdx6500SPCTSDLCStationEntry 22 } -- The SDLC Station Statistics Table -- This table contains Statistics paramaters -- for the SDLC Station table. cdx6500SPSTSDLCStationTable OBJECT-TYPE SYNTAX SEQUENCE OF Cdx6500SPSTSDLCStationEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "All of the statistics parameters relevant to the SDLC Station table." ::= { cdx6500PSTStationProtocolGroup 4 } cdx6500SPSTSDLCStationEntry OBJECT-TYPE SYNTAX Cdx6500SPSTSDLCStationEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A row of SDLC station Statistics parameters." INDEX { cdx6500sdlcsStatsPortNum, cdx6500sdlcsStatsStationNum } ::= { cdx6500SPSTSDLCStationTable 1 } Cdx6500SPSTSDLCStationEntry ::= SEQUENCE { cdx6500sdlcsStatsPortNum INTEGER, cdx6500sdlcsStatsStationNum INTEGER, cdx6500sdlcsStatsStationAddr INTEGER, cdx6500sdlcsQLLCState DisplayString, cdx6500sdlcsCharInTotal Counter, cdx6500sdlcsCharOutTotal Counter, cdx6500sdlcsCharsInPerSec INTEGER, cdx6500sdlcsCharsOutPerSec INTEGER, cdx6500sdlcsFrameInTotal Counter, cdx6500sdlcsFrameOutTotal Counter, cdx6500sdlcsFramesInPerSec INTEGER, cdx6500sdlcsFramesOutPerSec INTEGER, cdx6500sdlcsQRRInTotal Counter16, cdx6500sdlcsQRROutTotal Counter16, cdx6500sdlcsUtilizationIn INTEGER, cdx6500sdlcsUtilizationOut INTEGER, cdx6500sdlcsPacketsQueued INTEGER, cdx6500sdlcsRRInFrames Counter, cdx6500sdlcsRROutFrames Counter, cdx6500sdlcsRNRInFrames Counter, cdx6500sdlcsRNROutFrames Counter, cdx6500sdlcsSNRMInFrames Counter, cdx6500sdlcsSNRMOutFrames Counter, cdx6500sdlcsUAInFrames Counter, cdx6500sdlcsUAOutFrames Counter, cdx6500sdlcsDMInFrames Counter, cdx6500sdlcsDMOutFrames Counter, cdx6500sdlcsXIDInFrames Counter, cdx6500sdlcsXIDOutFrames Counter, cdx6500sdlcsREJInFrames Counter, cdx6500sdlcsREJOutFrames Counter, cdx6500sdlcsDISCInFrames Counter, cdx6500sdlcsDISCOutFrames Counter, cdx6500sdlcsRDInFrames Counter, cdx6500sdlcsRDOutFrames Counter, cdx6500sdlcsFRMRInFrames Counter, cdx6500sdlcsFRMROutFrames Counter, cdx6500sdlcsUPInFrames Counter, cdx6500sdlcsUPOutFrames Counter, cdx6500sdlcsTESTInFrames Counter, cdx6500sdlcsTESTOutFrames Counter, cdx6500sdlcsQSMInFrames Counter16, cdx6500sdlcsQSMOutFrames Counter16, cdx6500sdlcsQUAInFrames Counter16, cdx6500sdlcsQUAOutFrames Counter16, cdx6500sdlcsQRDInFrames Counter16, cdx6500sdlcsQRDOutFrames Counter16, cdx6500sdlcsQFRMRInFrames Counter16, cdx6500sdlcsQFRMROutFrames Counter16, cdx6500sdlcsQXIDInFrames Counter16, cdx6500sdlcsQXIDOutFrames Counter16, cdx6500sdlcsQDCInFrames Counter16, cdx6500sdlcsQDCOutFrames Counter16, cdx6500sdlcsQDMInFrames Counter16, cdx6500sdlcsQDMOutFrames Counter16, cdx6500sdlcsQTESTInFrames Counter16, cdx6500sdlcsQTESTOutFrames Counter16, cdx6500sdlcsQSSInFrames Counter16, cdx6500sdlcsQSSOutFrames Counter16, cdx6500sdlcsQRSInFrames Counter16, cdx6500sdlcsQRSOutFrames Counter16, cdx6500sdlcsXIDNullInFrames Counter, cdx6500sdlcsXIDNullOutFrames Counter, cdx6500sdlcsXID0InFrames Counter, cdx6500sdlcsXID0OutFrames Counter, cdx6500sdlcsXID1InFrames Counter, cdx6500sdlcsXID1OutFrames Counter, cdx6500sdlcsXID3InFrames Counter, cdx6500sdlcsXID3OutFrames Counter, cdx6500sdlcsVSNumber INTEGER, cdx6500sdlcsVRNumber INTEGER, cdx6500sdlcsNRNumber INTEGER, cdx6500sdlcsNSNumber INTEGER } cdx6500sdlcsStatsPortNum OBJECT-TYPE SYNTAX INTEGER (1..54) ACCESS read-only STATUS mandatory DESCRIPTION "Refers to the physical port number." ::= { cdx6500SPSTSDLCStationEntry 1 } cdx6500sdlcsStatsStationNum OBJECT-TYPE SYNTAX INTEGER (1..32) ACCESS read-only STATUS mandatory DESCRIPTION "Station reference number." ::= { cdx6500SPSTSDLCStationEntry 2 } cdx6500sdlcsStatsStationAddr OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "Configured station address." ::= { cdx6500SPSTSDLCStationEntry 3 } cdx6500sdlcsQLLCState OBJECT-TYPE SYNTAX DisplayString (SIZE(0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the status of the QLLC layer: INOPERATIVE : No connection exists with the station. LINK-CLOSED : X.25 call is connected, but there has been no successful QXID exchange and data cannot pass. LINK-OPENING: The X.25 call is connected and there has been a successful QXID exchange. However, there has been no QUA or QDM response to a QSM command. LINK-OPENED : X.25 call is connected and data is passing. LINK-CLOSING: Disconnect in process. Station may come back up after an SVC clear or PVC reset. If it does not, boot the station to clear it. LINK-RECOVERY: X.25 call is connected and the station has sent a QFRMR packet over the link. Station may come back up after SVC clear or PVC reset. If it does not recover, boot the station to clear it. NOTE: This value is not supported by the 6500." ::= { cdx6500SPSTSDLCStationEntry 4 } cdx6500sdlcsCharInTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of characters received until now, not including SDLC header characters." ::= { cdx6500SPSTSDLCStationEntry 5 } cdx6500sdlcsCharOutTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of characters transmitted until now, not including SDLC header characters." ::= { cdx6500SPSTSDLCStationEntry 6 } cdx6500sdlcsCharsInPerSec OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The average number of characters received per second during the previous minute." ::= { cdx6500SPSTSDLCStationEntry 7 } cdx6500sdlcsCharsOutPerSec OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The average number of characters transmitted per second during the previous minute." ::= { cdx6500SPSTSDLCStationEntry 8 } cdx6500sdlcsFrameInTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of frames received." ::= { cdx6500SPSTSDLCStationEntry 9 } cdx6500sdlcsFrameOutTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of frames transmitted." ::= { cdx6500SPSTSDLCStationEntry 10 } cdx6500sdlcsFramesInPerSec OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The average number of frames received per second during the previous minute." ::= { cdx6500SPSTSDLCStationEntry 11 } cdx6500sdlcsFramesOutPerSec OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The average number of frames transmitted per second during the previous minute." ::= { cdx6500SPSTSDLCStationEntry 12 } cdx6500sdlcsQRRInTotal OBJECT-TYPE SYNTAX Counter16 ACCESS read-only STATUS mandatory DESCRIPTION "Total number of QRR packets received until now." ::= { cdx6500SPSTSDLCStationEntry 13 } cdx6500sdlcsQRROutTotal OBJECT-TYPE SYNTAX Counter16 ACCESS read-only STATUS mandatory DESCRIPTION "Total number of QRR packets transmitted until now." ::= { cdx6500SPSTSDLCStationEntry 14 } cdx6500sdlcsUtilizationIn OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicates a percentage of the link resources currently in use in the IN(from the line to the port) direction." ::= { cdx6500SPSTSDLCStationEntry 15 } cdx6500sdlcsUtilizationOut OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicates a percentage of the link resources currently in use in the OUT(from the port to the line) direction." ::= { cdx6500SPSTSDLCStationEntry 16 } cdx6500sdlcsPacketsQueued OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Total number of packets queued at the SDLC protocol layer by the transmitter." ::= { cdx6500SPSTSDLCStationEntry 17 } cdx6500sdlcsRRInFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of RR frames received until the present time." ::= { cdx6500SPSTSDLCStationEntry 18 } cdx6500sdlcsRROutFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of RR frames transmitted until the present time." ::= { cdx6500SPSTSDLCStationEntry 19 } cdx6500sdlcsRNRInFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of RNR frames received until the present time." ::= { cdx6500SPSTSDLCStationEntry 20 } cdx6500sdlcsRNROutFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of RNR frames transmitted until the present time." ::= { cdx6500SPSTSDLCStationEntry 21 } cdx6500sdlcsSNRMInFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of SNRM frames received until the present time." ::= { cdx6500SPSTSDLCStationEntry 22 } cdx6500sdlcsSNRMOutFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of SNRM frames transmitted until the present time." ::= { cdx6500SPSTSDLCStationEntry 23 } cdx6500sdlcsUAInFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of UA frames received until the present time." ::= { cdx6500SPSTSDLCStationEntry 24 } cdx6500sdlcsUAOutFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of UA frames transmitted until the present time." ::= { cdx6500SPSTSDLCStationEntry 25 } cdx6500sdlcsDMInFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of DM frames received until the present time." ::= { cdx6500SPSTSDLCStationEntry 26 } cdx6500sdlcsDMOutFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of DM frames transmitted until the present time." ::= { cdx6500SPSTSDLCStationEntry 27 } cdx6500sdlcsXIDInFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of XID frames received until the present time." ::= { cdx6500SPSTSDLCStationEntry 28 } cdx6500sdlcsXIDOutFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of XID frames transmitted until the present time." ::= { cdx6500SPSTSDLCStationEntry 29 } cdx6500sdlcsREJInFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of REJ frames received until the present time." ::= { cdx6500SPSTSDLCStationEntry 30 } cdx6500sdlcsREJOutFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of REJ frames transmitted until the present time." ::= { cdx6500SPSTSDLCStationEntry 31 } cdx6500sdlcsDISCInFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of DISC frames received until the present time." ::= { cdx6500SPSTSDLCStationEntry 32 } cdx6500sdlcsDISCOutFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of DISC frames transmitted until the present time." ::= { cdx6500SPSTSDLCStationEntry 33 } cdx6500sdlcsRDInFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of RD frames received until the present time." ::= { cdx6500SPSTSDLCStationEntry 34 } cdx6500sdlcsRDOutFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of RD frames transmitted until the present time." ::= { cdx6500SPSTSDLCStationEntry 35 } cdx6500sdlcsFRMRInFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of FRMR frames received until the present time." ::= { cdx6500SPSTSDLCStationEntry 36 } cdx6500sdlcsFRMROutFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of FRMR frames transmitted until the present time." ::= { cdx6500SPSTSDLCStationEntry 37 } cdx6500sdlcsUPInFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of UP frames received until the present time." ::= { cdx6500SPSTSDLCStationEntry 38 } cdx6500sdlcsUPOutFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of UP frames transmitted until the present time." ::= { cdx6500SPSTSDLCStationEntry 39 } cdx6500sdlcsTESTInFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of TEST frames received until the present time." ::= { cdx6500SPSTSDLCStationEntry 40 } cdx6500sdlcsTESTOutFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of TEST frames transmitted until the present time." ::= { cdx6500SPSTSDLCStationEntry 41 } cdx6500sdlcsQSMInFrames OBJECT-TYPE SYNTAX Counter16 ACCESS read-only STATUS mandatory DESCRIPTION "Total number of QSM packets received until the present time." ::= { cdx6500SPSTSDLCStationEntry 42 } cdx6500sdlcsQSMOutFrames OBJECT-TYPE SYNTAX Counter16 ACCESS read-only STATUS mandatory DESCRIPTION "Total number of QSM packets transmitted until the present time." ::= { cdx6500SPSTSDLCStationEntry 43 } cdx6500sdlcsQUAInFrames OBJECT-TYPE SYNTAX Counter16 ACCESS read-only STATUS mandatory DESCRIPTION "Total number of QUA packets received until the present time." ::= { cdx6500SPSTSDLCStationEntry 44 } cdx6500sdlcsQUAOutFrames OBJECT-TYPE SYNTAX Counter16 ACCESS read-only STATUS mandatory DESCRIPTION "Total number of QUA packets transmitted until the present time." ::= { cdx6500SPSTSDLCStationEntry 45 } cdx6500sdlcsQRDInFrames OBJECT-TYPE SYNTAX Counter16 ACCESS read-only STATUS mandatory DESCRIPTION "Total number of QRD packets received until the present time." ::= { cdx6500SPSTSDLCStationEntry 46 } cdx6500sdlcsQRDOutFrames OBJECT-TYPE SYNTAX Counter16 ACCESS read-only STATUS mandatory DESCRIPTION "Total number of QRD packets transmitted until the present time." ::= { cdx6500SPSTSDLCStationEntry 47 } cdx6500sdlcsQFRMRInFrames OBJECT-TYPE SYNTAX Counter16 ACCESS read-only STATUS mandatory DESCRIPTION "Total number of QFRMR packets received until the present time." ::= { cdx6500SPSTSDLCStationEntry 48 } cdx6500sdlcsQFRMROutFrames OBJECT-TYPE SYNTAX Counter16 ACCESS read-only STATUS mandatory DESCRIPTION "Total number of QFRMR packets transmitted until the present time." ::= { cdx6500SPSTSDLCStationEntry 49 } cdx6500sdlcsQXIDInFrames OBJECT-TYPE SYNTAX Counter16 ACCESS read-only STATUS mandatory DESCRIPTION "Total number of QXID packets received until the present time." ::= { cdx6500SPSTSDLCStationEntry 50 } cdx6500sdlcsQXIDOutFrames OBJECT-TYPE SYNTAX Counter16 ACCESS read-only STATUS mandatory DESCRIPTION "Total number of QXID packets transmitted until the present time." ::= { cdx6500SPSTSDLCStationEntry 51 } cdx6500sdlcsQDCInFrames OBJECT-TYPE SYNTAX Counter16 ACCESS read-only STATUS mandatory DESCRIPTION "Total number of QDC packets received until the present time." ::= { cdx6500SPSTSDLCStationEntry 52 } cdx6500sdlcsQDCOutFrames OBJECT-TYPE SYNTAX Counter16 ACCESS read-only STATUS mandatory DESCRIPTION "Total number of QDC packets transmitted until the present time." ::= { cdx6500SPSTSDLCStationEntry 53 } cdx6500sdlcsQDMInFrames OBJECT-TYPE SYNTAX Counter16 ACCESS read-only STATUS mandatory DESCRIPTION "Total number of QDM packets received until the present time." ::= { cdx6500SPSTSDLCStationEntry 54 } cdx6500sdlcsQDMOutFrames OBJECT-TYPE SYNTAX Counter16 ACCESS read-only STATUS mandatory DESCRIPTION "Total number of QDM packets transmitted until the present time." ::= { cdx6500SPSTSDLCStationEntry 55 } cdx6500sdlcsQTESTInFrames OBJECT-TYPE SYNTAX Counter16 ACCESS read-only STATUS mandatory DESCRIPTION "Total number of QTEST packets received until the present time." ::= { cdx6500SPSTSDLCStationEntry 56 } cdx6500sdlcsQTESTOutFrames OBJECT-TYPE SYNTAX Counter16 ACCESS read-only STATUS mandatory DESCRIPTION "Total number of QTEST packets transmitted until the present time." ::= { cdx6500SPSTSDLCStationEntry 57 } cdx6500sdlcsQSSInFrames OBJECT-TYPE SYNTAX Counter16 ACCESS read-only STATUS mandatory DESCRIPTION "Total number of QSS packets received until the present time." ::= { cdx6500SPSTSDLCStationEntry 58 } cdx6500sdlcsQSSOutFrames OBJECT-TYPE SYNTAX Counter16 ACCESS read-only STATUS mandatory DESCRIPTION "Total number of QSS packets transmitted until the present time." ::= { cdx6500SPSTSDLCStationEntry 59 } cdx6500sdlcsQRSInFrames OBJECT-TYPE SYNTAX Counter16 ACCESS read-only STATUS mandatory DESCRIPTION "Total number of QRS packets received until the present time." ::= { cdx6500SPSTSDLCStationEntry 60 } cdx6500sdlcsQRSOutFrames OBJECT-TYPE SYNTAX Counter16 ACCESS read-only STATUS mandatory DESCRIPTION "Total number of QRS packets transmitted until the present time." ::= { cdx6500SPSTSDLCStationEntry 61 } cdx6500sdlcsXIDNullInFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of XID Null frames received until the present time." ::= { cdx6500SPSTSDLCStationEntry 62 } cdx6500sdlcsXIDNullOutFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of XID Null frames transmitted until the present time." ::= { cdx6500SPSTSDLCStationEntry 63 } cdx6500sdlcsXID0InFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of XID Type 0 frames received until the present time." ::= { cdx6500SPSTSDLCStationEntry 64 } cdx6500sdlcsXID0OutFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of XID Type 0 frames transmitted until the present time." ::= { cdx6500SPSTSDLCStationEntry 65 } cdx6500sdlcsXID1InFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of XID Type 1 frames received until the present time." ::= { cdx6500SPSTSDLCStationEntry 66 } cdx6500sdlcsXID1OutFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of XID Type 1 frames transmitted until the present time." ::= { cdx6500SPSTSDLCStationEntry 67 } cdx6500sdlcsXID3InFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of XID Type 3 frames received until the present time." ::= { cdx6500SPSTSDLCStationEntry 68 } cdx6500sdlcsXID3OutFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of XID Type 3 frames transmitted until the present time." ::= { cdx6500SPSTSDLCStationEntry 69 } cdx6500sdlcsVSNumber OBJECT-TYPE SYNTAX INTEGER (0..8) ACCESS read-only STATUS mandatory DESCRIPTION "Next VS seuqunce number this station expects." ::= { cdx6500SPSTSDLCStationEntry 70 } cdx6500sdlcsVRNumber OBJECT-TYPE SYNTAX INTEGER (0..8) ACCESS read-only STATUS mandatory DESCRIPTION "Next VR seuqunce number this station expects." ::= { cdx6500SPSTSDLCStationEntry 71 } cdx6500sdlcsNRNumber OBJECT-TYPE SYNTAX INTEGER (0..8) ACCESS read-only STATUS mandatory DESCRIPTION "Next NR seuqunce number this station expects." ::= { cdx6500SPSTSDLCStationEntry 72 } cdx6500sdlcsNSNumber OBJECT-TYPE SYNTAX INTEGER (0..8) ACCESS read-only STATUS mandatory DESCRIPTION "Next NS seuqunce number this station expects." ::= { cdx6500SPSTSDLCStationEntry 73 } -- The SDLC Station Controls Table -- This table contains Control paramaters -- for the SDLC Station table. cdx6500ContSDLCStationTable OBJECT-TYPE SYNTAX SEQUENCE OF Cdx6500ContSDLCStationEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "All of the control parameters relevant to the SDLC Station table." ::= { cdx6500ContSDLC 1 } cdx6500ContSDLCStationEntry OBJECT-TYPE SYNTAX Cdx6500ContSDLCStationEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A row of SDLC Station Control parameters." INDEX { cdx6500sdlcsContPortNum, cdx6500sdlcsContStationNum } ::= { cdx6500ContSDLCStationTable 1 } Cdx6500ContSDLCStationEntry ::= SEQUENCE { cdx6500sdlcsContPortNum INTEGER, cdx6500sdlcsContStationNum INTEGER, cdx6500sdlcsContBootStation INTEGER, cdx6500sdlcsContDisableStation INTEGER, cdx6500sdlcsContEnableStation INTEGER, cdx6500sdlcsContBusyOutStation INTEGER, cdx6500sdlcsContResetStnStats INTEGER } cdx6500sdlcsContPortNum OBJECT-TYPE SYNTAX INTEGER (1..54) ACCESS not-accessible STATUS mandatory DESCRIPTION "Refers to the physical port number." ::= { cdx6500ContSDLCStationEntry 1 } cdx6500sdlcsContStationNum OBJECT-TYPE SYNTAX INTEGER (1..32) ACCESS not-accessible STATUS mandatory DESCRIPTION "Station reference number." ::= { cdx6500ContSDLCStationEntry 2 } cdx6500sdlcsContBootStation OBJECT-TYPE SYNTAX INTEGER { boot (1), noboot (2) } ACCESS write-only STATUS mandatory DESCRIPTION "Boots the specified SDLC station. boot - Boot Station noBoot - Do not boot Station" ::= { cdx6500ContSDLCStationEntry 3 } cdx6500sdlcsContDisableStation OBJECT-TYPE SYNTAX INTEGER { disable (1), nodisable (2) } ACCESS write-only STATUS mandatory DESCRIPTION "Disables the specified SDLC station. disable - Disable Station. noDisable - Do not disable Station." ::= { cdx6500ContSDLCStationEntry 4 } cdx6500sdlcsContEnableStation OBJECT-TYPE SYNTAX INTEGER { enable (1), noenable (2) } ACCESS write-only STATUS mandatory DESCRIPTION "Enables the specified SDLC station. enable - Enable Station. noEnable - Not not enable Station." ::= { cdx6500ContSDLCStationEntry 5 } cdx6500sdlcsContBusyOutStation OBJECT-TYPE SYNTAX INTEGER { busyout (1), nobusyout (2) } ACCESS write-only STATUS deprecated DESCRIPTION "This operation is no longer supported. Busy out the specified SDLC station. busyOut - Busyout Station. noBusyOut - Do not busyout Station." ::= { cdx6500ContSDLCStationEntry 6 } cdx6500sdlcsContResetStnStats OBJECT-TYPE SYNTAX INTEGER { reset (1), noreset (2) } ACCESS write-only STATUS mandatory DESCRIPTION "Resets statistics for the specified SDLC station reset - Reset Station Statistics noReset - Do not reset Station Statistics" ::= { cdx6500ContSDLCStationEntry 7 } END