SALIX-DS0-RTP-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF MODULE-IDENTITY, OBJECT-TYPE, Integer32, IpAddress, Counter32 FROM SNMPv2-SMI TimeStamp, RowStatus FROM SNMPv2-TC DisplayString FROM RFC1213-MIB InterfaceIndex FROM IF-MIB platform1 FROM SALIX-MIB; salixDsx0RtpMIB MODULE-IDENTITY LAST-UPDATED "9810130000Z" ORGANIZATION "SALIX Technologies" CONTACT-INFO "904 Wind River Lane Suite 101 Gaithersburg, MD 20878 (301)-417-0017" DESCRIPTION "The MIB describing Salix specific DS0-RTP connection objects" ::= { platform1 3 } salixDsx0RtpMIBObjects OBJECT IDENTIFIER ::= { salixDsx0RtpMIB 1 } salixDsx0RtpMIBTraps OBJECT IDENTIFIER ::= { salixDsx0RtpMIB 2 } salixDsx0RtpMIBCompliance OBJECT IDENTIFIER ::= { salixDsx0RtpMIB 3 } salixDsx0RtpMIBTrapPrefix OBJECT IDENTIFIER ::= { salixDsx0RtpMIBTraps 0 } -- ITX DS0-RTP Connection Table salixDsx0RtpConnectionTable OBJECT-TYPE SYNTAX SEQUENCE OF ItxDsx0RtpConnectionEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table describing the current DS0 to RTP connections. There should be one entry for each DS0-RTP connection in the system" ::= { salixDsx0RtpMIBObjects 1 } salixDsx0RtpConnectionEntry OBJECT-TYPE SYNTAX ItxDsx0RtpConnectionEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the ITX DS0-RTP Table. The entry provides information on the status and other attributes of the connection" INDEX { salixDsx0RtpConnectionInterface, salixDsx0RtpConnectionSrcIpAddress, salixDsx0RtpConnectionSrcPort, salixDsx0RtpConnectionDestIpAddress, salixDsx0RtpConnectionDestPort } ::= { salixDsx0RtpConnectionTable 1 } ItxDsx0RtpConnectionEntry ::= SEQUENCE { salixDsx0RtpConnectionInterface InterfaceIndex, salixDsx0RtpConnectionSrcIpAddress IpAddress, salixDsx0RtpConnectionSrcPort INTEGER, salixDsx0RtpConnectionDestIpAddress IpAddress, salixDsx0RtpConnectionDestPort INTEGER, salixDsx0RtpConnectionDirection INTEGER, salixDsx0RtpConnectionOperStatus INTEGER, salixDsx0RtpConnectionRowStatus RowStatus } salixDsx0RtpConnectionInterface OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS not-accessible STATUS current DESCRIPTION "The ifIndex that identifies the DS0 channel being connected to the RTP session" ::= { salixDsx0RtpConnectionEntry 1 } salixDsx0RtpConnectionSrcIpAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Source IP Address for the RTP Session part of the DS0-RTP connection" ::= { salixDsx0RtpConnectionEntry 2 } salixDsx0RtpConnectionSrcPort OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Source Port for the RTP Session part of the DS0-RTP connection" ::= { salixDsx0RtpConnectionEntry 3 } salixDsx0RtpConnectionDestIpAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Destination IP Address for the RTP Session part of the DS0-RTP connection" ::= { salixDsx0RtpConnectionEntry 4 } salixDsx0RtpConnectionDestPort OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Destination Port for the RTP Session part of the DS0-RTP connection" ::= { salixDsx0RtpConnectionEntry 5 } salixDsx0RtpConnectionDirection OBJECT-TYPE SYNTAX INTEGER { rtp2dsx0(1), dsx02rtp(2), bidirectional(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute describes the direction of traffic flow in a connection. rtp2dsx0 (1) - Traffic flows from the RTP session to the DS0 channel dsx02rtp (2) - Traffic flows from the DS0 channel to the RTP session bidirectional (3) - Traffic flows in both directions in the connection" ::= { salixDsx0RtpConnectionEntry 6 } salixDsx0RtpConnectionOperStatus OBJECT-TYPE SYNTAX INTEGER { up(1), down(2), unknown(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the operational state of the DS0-RTP connection. up (1) - The connection is up and active down (2) - The connection is down and inactive unknown (3) - The status of the connection is unknown" ::= { salixDsx0RtpConnectionEntry 7 } salixDsx0RtpConnectionRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-write STATUS current DESCRIPTION "The status of this entry in the salixDsx0RtpConnectTable. This object is used to delete a salixDsx0RtpConnectTable entry. To delete the connection, set this object to destory(6) Row status values: active(1) - set by the agent after this entry is created notInService(2) - not applicable notReady(3) - not applicable createAndGo(4) - not applicable createAndWait(5)- not applicable destroy(6) - set by the management entity to destroy entry" ::= { salixDsx0RtpConnectionEntry 8 } -- Conformance Statements salixDsx0RtpGroups OBJECT IDENTIFIER ::= { salixDsx0RtpMIBCompliance 1 } salixDsx0RtpCompliances OBJECT IDENTIFIER ::= { salixDsx0RtpMIBCompliance 2 } salixDsx0RtpGroup OBJECT-GROUP OBJECTS { salixDsx0RtpConnectionDirection, salixDsx0RtpConnectionOperStatus, salixDsx0RtpConnectionRowStatus } STATUS current DESCRIPTION "Current Statistics for Dsx0Rtp Sessions" ::= {salixDsx0RtpGroups 3} -- Compliance Statements salixDsx0RtpCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The basic implementation requirements for the SALIX-DS0-RTP-MIB." MODULE -- This module MANDATORY-GROUPS { salixDsx0RtpGroup } ::= { salixDsx0RtpCompliances 1 } END