-- ---------------------------------------------------------------------- -- -- Copyright (c) 2006 by Sinetica Corporation Ltd. -- -- Filename: RMS-C_SNMPv1_humid1.mib -- -- Author: Adrian Moruz -- -- Description: SNMPv1 MIB definition for the RMS Compact Humidity 1 notifications -- -- $Id: RMS-C_SNMPv1_humid1.mib,v 1.1 2006/10/11 11:22:24 adrian.moruz Exp $ -- -- $Name: $ -- -- $Log: RMS-C_SNMPv1_humid1.mib,v $ -- Revision 1.1 2006/10/11 11:22:24 adrian.moruz -- Created from RMS-C_SNMPv1.mib v1.2 to separate the different trap enterprise groups into separate MIBs -- -- -- ---------------------------------------------------------------------- RMS-COMPACT-SNMPv1-HUMID1-MIB DEFINITIONS ::= BEGIN -- {{{ Imports -- OBJECT-TYPE, Counter32, Unsigned32, IMPORTS TRAP-TYPE FROM RFC-1215 sysDescr, sysName, DisplayString FROM RFC1213-MIB OBJECT-TYPE FROM RFC-1212 enterprises FROM RFC1155-SMI ; -- }}} sinetica OBJECT IDENTIFIER ::= { enterprises 3711 } rms-compact OBJECT IDENTIFIER ::= { sinetica 15 } rms-compact1 OBJECT IDENTIFIER ::= { rms-compact 1 } rms-cObjects OBJECT IDENTIFIER ::= { rms-compact1 1 } -- {{{ rms-cObjects rms-cEnviroment OBJECT IDENTIFIER ::= { rms-cObjects 1 } -- }}} -- {{{ rms-cTemp group rms-cHumid1 OBJECT IDENTIFIER ::= { rms-cEnviroment 2 } -- }}} -- {{{ rms-cHumid1LowControlLimitAlarm TRAP-TYPE ENTERPRISE rms-cHumid1 VARIABLES { sysDescr, sysName, rms-cHumid1Name, rms-cHumid1LowerControlLevel } DESCRIPTION "Humidity is below the low control limit." --#TYPE "Humidity 1 below low control limit" --#SUMMARY "Humidity %s below %d in %s at %s" --#ARGUMENTS {2,3,0,1} --#SEVERITY MAJOR --#TIMEINDEX 4 --#STATE NONOPERATIONAL ::= 111 rms-cHumid1LowWarningLimitAlarm TRAP-TYPE ENTERPRISE rms-cHumid1 VARIABLES { sysDescr, sysName, rms-cHumid1Name, rms-cHumid1LowerWarningLevel } DESCRIPTION "Humidity is below the low warning limit." --#TYPE "Humidity 1 below low warning limit" --#SUMMARY "Humidity %s below %d in %s at %s" --#ARGUMENTS {2,3,0,1} --#SEVERITY MINOR --#TIMEINDEX 4 --#STATE NONOPERATIONAL ::= 112 rms-cHumid1HighWarningLimitAlarm TRAP-TYPE ENTERPRISE rms-cHumid1 VARIABLES { sysDescr, sysName, rms-cHumid1Name, rms-cHumid1UpperWarningLevel } DESCRIPTION "Humidity is over the high warning limit." --#TYPE "Humidity 1 above high warning limit" --#SUMMARY "Humidity %s above %d in %s at %s" --#ARGUMENTS {2,3,0,1} --#SEVERITY MINOR --#TIMEINDEX 4 --#STATE NONOPERATIONAL ::= 113 rms-cHumid1HighControlLimitAlarm TRAP-TYPE ENTERPRISE rms-cHumid1 VARIABLES { sysDescr, sysName, rms-cHumid1Name, rms-cHumid1UpperControlLevel } DESCRIPTION "Humidity is over the high control limit." --#TYPE "Humidity 1 above high control limit" --#SUMMARY "Humidity %s above %d in %s at %s" --#ARGUMENTS {2,3,0,1} --#SEVERITY MAJOR --#TIMEINDEX 4 --#STATE NONOPERATIONAL ::= 114 rms-cHumid1LowControlLimitNormal TRAP-TYPE ENTERPRISE rms-cHumid1 VARIABLES { sysDescr, sysName, rms-cHumid1Name, rms-cHumid1LowerControlLevel } DESCRIPTION "Humidity is inside the low control limit." --#TYPE "Humidity 1 above low control limit" --#SUMMARY "Humidity %s above %d in %s at %s" --#ARGUMENTS {2,3,0,1} --#SEVERITY INFORMATIONAL --#TIMEINDEX 4 --#STATE NONOPERATIONAL ::= 115 rms-cHumid1LowWarningLimitNormal TRAP-TYPE ENTERPRISE rms-cHumid1 VARIABLES { sysDescr, sysName, rms-cHumid1Name, rms-cHumid1LowerWarningLevel } DESCRIPTION "Humidity is inside the low warning limit." --#TYPE "Humidity 1 above low warning limit" --#SUMMARY "Humidity %s above %d in %s at %s" --#ARGUMENTS {2,3,0,1} --#SEVERITY INFORMATIONAL --#TIMEINDEX 4 --#STATE NONOPERATIONAL ::= 116 rms-cHumid1HighWarningLimitNormal TRAP-TYPE ENTERPRISE rms-cHumid1 VARIABLES { sysDescr, sysName, rms-cHumid1Name, rms-cHumid1UpperWarningLevel } DESCRIPTION "Humidity is inside the high warning limit." --#TYPE "Humidity 1 below high warning limit" --#SUMMARY "Humidity %s below %d in %s at %s" --#ARGUMENTS {2,3,0,1} --#SEVERITY INFORMATIONAL --#TIMEINDEX 4 --#STATE NONOPERATIONAL ::= 117 rms-cHumid1HighControlLimitNormal TRAP-TYPE ENTERPRISE rms-cHumid1 VARIABLES { sysDescr, sysName, rms-cHumid1Name, rms-cHumid1UpperControlLevel } DESCRIPTION "Humidity is inside the high control limit." --#TYPE "Humidity 1 below high control limit" --#SUMMARY "Humidity %s below %d in %s at %s" --#ARGUMENTS {2,3,0,1} --#SEVERITY INFORMATIONAL --#TIMEINDEX 4 --#STATE NONOPERATIONAL ::= 118 -- }}} END