-- ***************************************************************** -- REDSTONE-ATM-MIB -- -- Redstone Communications Inc. Enterprise MIB -- ATM MIB -- -- Copyright 1998 Redstone Communications, Incorporated. -- All Rights Reserved. -- ***************************************************************** REDSTONE-ATM-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, Integer32 FROM SNMPv2-SMI OBJECT-GROUP, MODULE-COMPLIANCE FROM SNMPv2-CONF RowStatus FROM SNMPv2-TC InterfaceIndex, InterfaceIndexOrZero FROM IF-MIB rsMgmt FROM REDSTONE-SMI RsNextIfIndex FROM REDSTONE-TC; rsAtmMIB MODULE-IDENTITY LAST-UPDATED "9908040000Z" ORGANIZATION "Redstone Communications, Inc." CONTACT-INFO " Redstone Communications, Inc. 5 Carlisle Road Westford MA 01886 USA Tel: +1-978-692-1999 Email: mib@redstonecom.com " DESCRIPTION "The ATM MIB for the Redstone Communications Inc. enterprise." REVISION "9908040000Z" DESCRIPTION "Initial version of this MIB module." ::= { rsMgmt 8 } -- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ -- Textual conventions -- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ -- No textual conventions are defined in this MIB. -- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ -- Managed objects -- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ rsAtmObjects OBJECT IDENTIFIER ::= { rsAtmMIB 1 } -- -- This MIB contains managed objects for each of three interface -- layers: ATM; AAL5; and ATM Subinterface. For each of these layers, -- management objects are provided to query for an available -- interface index, and to create/delete interfaces of that type. -- Creating/deleting these interface types using this MIB has -- the side effect of creating/deleting corresponding entries -- in the Interface MIB ifTable/ifXTable, and in the Redstone -- Enterprise Interface MIB rsIfTable. -- rsAtmIfLayer OBJECT IDENTIFIER ::= { rsAtmObjects 1 } rsAtmAal5IfLayer OBJECT IDENTIFIER ::= { rsAtmObjects 2 } rsAtmSubIfLayer OBJECT IDENTIFIER ::= { rsAtmObjects 3 } -- ////////////////////////////////////////////////////////////////////// -- -- ATM LAYER -- -- ////////////////////////////////////////////////////////////////////// -- -- IfIndex selection for creating new ATM interfaces -- rsAtmNextIfIndex OBJECT-TYPE SYNTAX RsNextIfIndex MAX-ACCESS read-only STATUS current DESCRIPTION "Coordinate ifIndex value allocation for entries in rsAtmIfTable. A GET of this object returns the next available ifIndex value to be used to create an entry in the associated interface table; or zero, if no valid ifIndex value is available. This object also returns a value of zero when it is the lexicographic successor of a varbind presented in an SNMP GETNEXT or GETBULK request, for which circumstance it is assumed that ifIndex allocation is unintended. Successive GETs will typically return different values, thus avoiding collisions among cooperating management clients seeking to create table entries simultaneously. " ::= { rsAtmIfLayer 1 } -- -- The ATM Interface Table -- rsAtmIfTable OBJECT-TYPE SYNTAX SEQUENCE OF RsAtmIfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains entries for ATM interfaces present in the system." ::= { rsAtmIfLayer 2 } rsAtmIfEntry OBJECT-TYPE SYNTAX RsAtmIfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each entry describes the characteristics of an ATM interface. Creating/deleting entries in this table causes corresponding entries for be created /deleted in ifTable/ifXTable/rsIfTable." INDEX { rsAtmIfIndex } ::= { rsAtmIfTable 1 } RsAtmIfEntry ::= SEQUENCE { rsAtmIfIndex InterfaceIndex, rsAtmIfRowStatus RowStatus, rsAtmIfLowerIfIndex InterfaceIndexOrZero, rsAtmIfIlmiVpi Integer32, rsAtmIfIlmiVci Integer32, rsAtmIfIlmiVcd Integer32, rsAtmIfIlmiPollFrequency Integer32, rsAtmIfIlmiAdminState INTEGER, rsAtmIfUniVersion INTEGER } rsAtmIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS not-accessible STATUS current DESCRIPTION "The ifIndex of the ATM interface. When creating entries in this table, suitable values for this object are determined by reading rsAtmNextIfIndex." ::= { rsAtmIfEntry 1 } rsAtmIfRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Controls creation/deletion of entries in this table according to the RowStatus textual convention, constrained to support the following values only: createAndGo destroy To create an entry in this table, the following entry objects MUST be explicitly configured: rsAtmIfRowStatus rsAtmIfLowerIfIndex In addition, when creating an entry the following conditions must hold: A value for rsAtmIfIndex must have been determined previously, by reading rsAtmNextIfIndex. A corresponding entry in ifTable/ifXTable/rsIfTable is created/destroyed as a result of creating/destroying an entry in this table. " ::= { rsAtmIfEntry 2 } rsAtmIfLowerIfIndex OBJECT-TYPE SYNTAX InterfaceIndexOrZero MAX-ACCESS read-create STATUS current DESCRIPTION "The ifIndex of an interface over which this ATM interface is to be layered. A value of zero indicates no layering. An implementation may choose to require that a nonzero value be configured at entry creation." ::= { rsAtmIfEntry 3 } rsAtmIfIlmiVpi OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-write STATUS current DESCRIPTION "The VPI of the Ilmi of a major ATM interface." DEFVAL { 0 } ::= { rsAtmIfEntry 4 } rsAtmIfIlmiVci OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "The VCI of the Ilmi of a major ATM interface." DEFVAL { 16 } ::= { rsAtmIfEntry 5 } rsAtmIfIlmiVcd OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "An integer identifier for the Ilmi, used in conjunction with the command-line interface. The value must be unique among VCs configured on the same ATM interface. " DEFVAL { 0 } ::= { rsAtmIfEntry 6 } rsAtmIfIlmiPollFrequency OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Use to set the Interim Local Management Interface (ILMI) keepalive timer. This value sets the allowable time between POLL PDU transmissions if there are no pending sequence data PDUs. Use the value 0 to disable ILMI keepalives." ::= { rsAtmIfEntry 7 } rsAtmIfIlmiAdminState OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "The administrative status of ILMI in the ATM interface." ::= { rsAtmIfEntry 8 } rsAtmIfUniVersion OBJECT-TYPE SYNTAX INTEGER { version3Dot0(0), version3Dot1(1), version4Dot0(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Use to specify the User Network Interface (UNI) the router should use when ILMI link auto determination is unsuccesful or ILMI is disabled." ::= { rsAtmIfEntry 9 } -- ////////////////////////////////////////////////////////////////////// -- -- AAL5 LAYER -- -- ////////////////////////////////////////////////////////////////////// -- -- IfIndex selection for creating new ATM AAL5 interfaces -- rsAtmAal5NextIfIndex OBJECT-TYPE SYNTAX RsNextIfIndex MAX-ACCESS read-only STATUS current DESCRIPTION "Coordinate ifIndex value allocation for entries in rsAtmAal5IfTable. A GET of this object returns the next available ifIndex value to be used to create an entry in the associated interface table; or zero, if no valid ifIndex value is available. This object also returns a value of zero when it is the lexicographic successor of a varbind presented in an SNMP GETNEXT or GETBULK request, for which circumstance it is assumed that ifIndex allocation is unintended. Successive GETs will typically return different values, thus avoiding collisions among cooperating management clients seeking to create table entries simultaneously. " ::= { rsAtmAal5IfLayer 1 } -- -- The ATM AAL5 Interface Table -- rsAtmAal5IfTable OBJECT-TYPE SYNTAX SEQUENCE OF RsAtmAal5IfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains entries for ATM AAL5 interfaces present in the system." ::= { rsAtmAal5IfLayer 2 } rsAtmAal5IfEntry OBJECT-TYPE SYNTAX RsAtmAal5IfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each entry describes the characteristics of an ATM AAL5 interface. Creating/deleting entries in this table causes corresponding entries for be created /deleted in ifTable/ifXTable/rsIfTable." INDEX { rsAtmAal5IfIndex } ::= { rsAtmAal5IfTable 1 } RsAtmAal5IfEntry ::= SEQUENCE { rsAtmAal5IfIndex InterfaceIndex, rsAtmAal5IfRowStatus RowStatus, rsAtmAal5IfLowerIfIndex InterfaceIndexOrZero } rsAtmAal5IfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS not-accessible STATUS current DESCRIPTION "The ifIndex of the ATM AAL5 interface. When creating entries in this table, suitable values for this object are determined by reading rsAtmAal5NextIfIndex." ::= { rsAtmAal5IfEntry 1 } rsAtmAal5IfRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Controls creation/deletion of entries in this table according to the RowStatus textual convention, constrained to support the following values only: createAndGo destroy To create an entry in this table, the following entry objects MUST be explicitly configured: rsAtmAal5IfRowStatus rsAtmAal5IfLowerIfIndex In addition, when creating an entry the following conditions must hold: A value for rsAtmAal5IfIndex must have been determined previously, by reading rsAtmAal5NextIfIndex. A corresponding entry in ifTable/ifXTable/rsIfTable is created/destroyed as a result of creating/destroying an entry in this table. " ::= { rsAtmAal5IfEntry 2 } rsAtmAal5IfLowerIfIndex OBJECT-TYPE SYNTAX InterfaceIndexOrZero MAX-ACCESS read-create STATUS current DESCRIPTION "The ifIndex of an ATM interface over which this ATM AAL5 interface is to be layered. A value of zero indicates no layering. An implementation may choose to require that a nonzero value be configured at entry creation." ::= { rsAtmAal5IfEntry 3 } -- ////////////////////////////////////////////////////////////////////// -- -- ATM SUBINTERFACE LAYER -- -- ////////////////////////////////////////////////////////////////////// -- -- IfIndex selection for creating new ATM Subinterfaces -- rsAtmSubIfNextIfIndex OBJECT-TYPE SYNTAX RsNextIfIndex MAX-ACCESS read-only STATUS current DESCRIPTION "Coordinate ifIndex value allocation for entries in rsAtmSubIfTable. A GET of this object returns the next available ifIndex value to be used to create an entry in the associated interface table; or zero, if no valid ifIndex value is available. This object also returns a value of zero when it is the lexicographic successor of a varbind presented in an SNMP GETNEXT or GETBULK request, for which circumstance it is assumed that ifIndex allocation is unintended. Successive GETs will typically return different values, thus avoiding collisions among cooperating management clients seeking to create table entries simultaneously. " ::= { rsAtmSubIfLayer 1 } -- -- The ATM Subinterface Table -- rsAtmSubIfTable OBJECT-TYPE SYNTAX SEQUENCE OF RsAtmSubIfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains entries for ATM Subinterfaces present in the system." ::= { rsAtmSubIfLayer 2 } rsAtmSubIfEntry OBJECT-TYPE SYNTAX RsAtmSubIfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each entry describes the characteristics of an ATM Subinterface. Creating/deleting entries in this table causes corresponding entries for be created /deleted in ifTable/ifXTable/rsIfTable." INDEX { rsAtmSubIfIndex } ::= { rsAtmSubIfTable 1 } RsAtmSubIfEntry ::= SEQUENCE { rsAtmSubIfIndex InterfaceIndex, rsAtmSubIfRowStatus RowStatus, rsAtmSubIfDistinguisher Integer32, rsAtmSubIfLowerIfIndex InterfaceIndexOrZero } rsAtmSubIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS not-accessible STATUS current DESCRIPTION "The ifIndex of the ATM Subinterface. When creating entries in this table, suitable values for this object are determined by reading rsAtmSubNextIfIndex." ::= { rsAtmSubIfEntry 1 } rsAtmSubIfRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Controls creation/deletion of entries in this table according to the RowStatus textual convention, constrained to support the following values only: createAndGo destroy To create an entry in this table, the following entry objects MUST be explicitly configured: rsAtmSubIfRowStatus rsAtmSubIfLowerIndex In addition, when creating an entry the following conditions must hold: A value for rsAtmSubIfIndex must have been determined previously, by reading rsAtmSubIfNextIfIndex. A corresponding entry in ifTable/ifXTable/rsIfTable is created/destroyed as a result of creating/destroying an entry in this table. " ::= { rsAtmSubIfEntry 2 } rsAtmSubIfDistinguisher OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "An integer identifier for the sub interface, used in conjunction with the command-line interface. It is provided here for cross-reference purposes only. The value must be unique among sub interfaces configured on the same underlying ATM adaptation layer. The upper bound for the value is further constrained to be identical with the maximum number of sub interfaces supported by the lower interface. If this object is not configured, a value will be allocated internally and can be queried after table entry creation has succeeded. " ::= { rsAtmSubIfEntry 3 } rsAtmSubIfLowerIfIndex OBJECT-TYPE SYNTAX InterfaceIndexOrZero MAX-ACCESS read-create STATUS current DESCRIPTION "The ifIndex of an ATM AAL5 interface over which this ATM Subinterface is to be layered. A value of zero indicates no layering. An implementation may choose to require that a nonzero value be configured at entry creation." ::= { rsAtmSubIfEntry 4 } -- -- The ATM Subinterface VCC Table -- rsAtmSubIfVccTable OBJECT-TYPE SYNTAX SEQUENCE OF RsAtmSubIfVccEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains entries for ATM VCCs configured on ATM Subinterfaces present in the system. An implementation may constrain the number of VCCs permitted to be configured per ATM Subinterface; in particular, an implementation may restrict each ATM Subinterface to have a single VCC. Attributes in this entry can only be configured at entry creation, and remain fixed for the lifetime of the entry. " ::= { rsAtmSubIfLayer 3 } rsAtmSubIfVccEntry OBJECT-TYPE SYNTAX RsAtmSubIfVccEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each entry describes the characteristics of an ATM Subinterface VCC." INDEX { rsAtmSubIfIndex, rsAtmSubIfVccVpi, rsAtmSubIfVccVci } ::= { rsAtmSubIfVccTable 1 } RsAtmSubIfVccEntry ::= SEQUENCE { rsAtmSubIfVccVpi Integer32, rsAtmSubIfVccVci Integer32, rsAtmSubIfVccRowStatus RowStatus, rsAtmSubIfVccVcd Integer32, rsAtmSubIfVccType INTEGER, rsAtmSubIfVccServiceCategory INTEGER, rsAtmSubIfVccPcr Integer32, rsAtmSubIfVccScr Integer32, rsAtmSubIfVccMbs Integer32 } rsAtmSubIfVccVpi OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The VPI of the ATM VCC used by this subinterface." ::= { rsAtmSubIfVccEntry 1 } rsAtmSubIfVccVci OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The VCI of the ATM VCC used by this subinterface." ::= { rsAtmSubIfVccEntry 2 } rsAtmSubIfVccRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Controls creation/deletion of entries in this table according to the RowStatus textual convention, constrained to support the following values only: createAndGo destroy To create an entry in this table, the following entry objects MUST be explicitly configured: rsAtmSubIfVccRowStatus In addition, when creating an entry the following conditions must hold: The ATM Subinterface identified by rsAtmSubIfIndex must exist. A positive value configured for rsAtmSubIfVccVcd must not already be assigned to an existing VCC. For each value of rsAtmSubIfVccServiceCategory, additional dependent objects in the entry require configuration as identified here: rsAtmSubIfVccServiceCategory Requires configuration of: ------------------------------------------------------------ ubr ubrPcr rsAtmSubIfVccPcr nrtVbr rsAtmSubIfVccPcr rsAtmSubIfVccScr rsAtmSubIfVccMbs ------------------------------------------------------------ Attributes in this entry can only be configured at entry creation, and remain fixed for the lifetime of the entry. " ::= { rsAtmSubIfVccEntry 3 } rsAtmSubIfVccVcd OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-create STATUS current DESCRIPTION "An integer identifier for the circuit, used in conjunction with the command-line interface. It is provided here for cross-reference purposes only. The value must be unique among VCCs configured on the same underlying ATM interface. The upper bound for the value is further constrained to be identical with the maximum number of VCCs supported by the underlying ATM interface. If this object is not configured, or is configured with a value of zero, a value will be allocated internally and can be queried after table entry creation has succeeded. " ::= { rsAtmSubIfVccEntry 4 } rsAtmSubIfVccType OBJECT-TYPE SYNTAX INTEGER { rfc1483VcMux(0), rfc1483Llc(1) } MAX-ACCESS read-create STATUS current DESCRIPTION "Specifies the encapsulation used by the circuit to carry IP datagrams. Encapsulations are as specified in RFC1483 Multiprotocol Interconnect over ATM." DEFVAL { rfc1483VcMux } ::= { rsAtmSubIfVccEntry 5 } rsAtmSubIfVccServiceCategory OBJECT-TYPE SYNTAX INTEGER { ubr(0), ubrPcr(1), nrtVbr(2) } MAX-ACCESS read-create STATUS current DESCRIPTION "Service category for this circuit: ubr Unspecified bit rate (best effort). ubrPcr Unspecified Bit Rate with Peak Cell Rate limit. nrtVbr Non-realtime Variable Bit Rate. " DEFVAL { ubr } ::= { rsAtmSubIfVccEntry 6 } rsAtmSubIfVccPcr OBJECT-TYPE SYNTAX Integer32 UNITS "cells per second" MAX-ACCESS read-create STATUS current DESCRIPTION "Peak Cell Rate, in cells per second, of this circuit. This parameter is only required when rsAtmSubIfVccServiceCategory is configured to have one of the following values: ubrPcr nrtVbr " DEFVAL { 0 } ::= { rsAtmSubIfVccEntry 7 } rsAtmSubIfVccScr OBJECT-TYPE SYNTAX Integer32 UNITS "cells per second" MAX-ACCESS read-create STATUS current DESCRIPTION "Sustained Cell Rate, in cells per second, of this circuit. This parameter is only required when rsAtmSubIfVccServiceCategory is configured to have one of the following values: nrtVbr " DEFVAL { 0 } ::= { rsAtmSubIfVccEntry 8 } rsAtmSubIfVccMbs OBJECT-TYPE SYNTAX Integer32 UNITS "cells" MAX-ACCESS read-create STATUS current DESCRIPTION "Maximum Burst Size, in cells, of this circuit. This parameter is only required when rsAtmSubIfVccServiceCategory is configured to have one of the following values: nrtVbr " DEFVAL { 0 } ::= { rsAtmSubIfVccEntry 9 } -- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ -- Notification control objects -- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ -- No notifications are defined in this MIB. Placeholder follows. -- rsAtmTrapControl OBJECT IDENTIFIER ::= { rsAtmMIB 2 } -- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ -- Notifications -- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ -- No notifications are defined in this MIB. Placeholder follows. -- The following two OBJECT IDENTIFIERS are used to define SNMPv2 -- Notifications that are easily translated into SNMPv1 Traps. -- rsAtmTraps OBJECT IDENTIFIER ::= { rsAtmMIB 3 } -- rsAtmTrapPrefix OBJECT IDENTIFIER ::= { rsAtmTraps 0 } -- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ -- Conformance information -- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ rsAtmConformance OBJECT IDENTIFIER ::= { rsAtmMIB 4 } rsAtmCompliances OBJECT IDENTIFIER ::= { rsAtmConformance 1 } rsAtmGroups OBJECT IDENTIFIER ::= { rsAtmConformance 2 } -- compliance statements rsAtmCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for entities which implement the Redstone ATM MIB." MODULE -- this module MANDATORY-GROUPS { rsAtmGroup, rsAtmAal5Group, rsAtmSubIfGroup } ::= { rsAtmCompliances 1 } -- units of conformance rsAtmGroup OBJECT-GROUP OBJECTS { rsAtmNextIfIndex, rsAtmIfRowStatus, rsAtmIfLowerIfIndex } STATUS current DESCRIPTION "A collection of objects providing management of ATM interfaces in a Redstone product." ::= { rsAtmGroups 1 } rsAtmAal5Group OBJECT-GROUP OBJECTS { rsAtmAal5NextIfIndex, rsAtmAal5IfRowStatus, rsAtmAal5IfLowerIfIndex } STATUS current DESCRIPTION "A collection of objects providing management of AAL5 interfaces in a Redstone product." ::= { rsAtmGroups 2 } rsAtmSubIfGroup OBJECT-GROUP OBJECTS { rsAtmSubIfNextIfIndex, rsAtmSubIfRowStatus, rsAtmSubIfLowerIfIndex, rsAtmSubIfVccRowStatus, rsAtmSubIfVccVcd, rsAtmSubIfVccType, rsAtmSubIfVccServiceCategory, rsAtmSubIfVccPcr, rsAtmSubIfVccScr, rsAtmSubIfVccMbs } STATUS current DESCRIPTION "A collection of objects providing management of ATM subinterfaces in a Redstone product." ::= { rsAtmGroups 3 } END