-- File Name : PACKETPOWER-EG4-MIB -- Date : Thu Feb 04 03:34:15 GMT 2016 -- Author : WebNMS Agent Toolkit C Edition - MibEditor 6 PACKETPOWER-EG4-MIB DEFINITIONS ::= BEGIN IMPORTS DateAndTime, DisplayString, RowStatus, TruthValue FROM SNMPv2-TC MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, enterprises, Integer32, Counter32, IpAddress FROM SNMPv2-SMI; org OBJECT IDENTIFIER ::= { iso 3 } dod OBJECT IDENTIFIER ::= { org 6 } internet OBJECT IDENTIFIER ::= { dod 1 } private OBJECT IDENTIFIER ::= { internet 4 } enterprises OBJECT IDENTIFIER ::= { private 1 } packetPower OBJECT IDENTIFIER ::= { enterprises 33688 } eg4 OBJECT IDENTIFIER ::= { packetPower 4 } readingsTable OBJECT-TYPE SYNTAX SEQUENCE OF ReadingsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of most recent, time-stamped readings on all channels monitored by each node." ::= { eg4 1 } readingsEntry OBJECT-TYPE SYNTAX ReadingsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Time-stamped reading corresponding to a physical value most recently reported on a given measurement channel." INDEX { reNodeId1, reNodeId2, reNodeId3, reNodeId4, channelId } ::= { readingsTable 1 } ReadingsEntry ::= SEQUENCE { reNodeId1 Integer32, reNodeId2 Integer32, reNodeId3 Integer32, reNodeId4 Integer32, channelId INTEGER, reNodeIdHex DisplayString, reNodeIdString DisplayString, reChannelName DisplayString, reTime DateAndTime, reUnixTime Integer32, reIso8601Time DisplayString, reValue Integer32, reUnits DisplayString } reNodeId1 OBJECT-TYPE SYNTAX Integer32 ( 0 .. 65536 ) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Node identifier, part 1 of 4 (16 bits, bits 63-48 of the id - part AAAA of AAAA-BBBB-CCCC-DDDD)." ::= { readingsEntry 1 } reNodeId2 OBJECT-TYPE SYNTAX Integer32 ( 0 .. 65536 ) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Node identifier, part 2 of 4 (16 bits, bits 47-32 of the id - part BBBB of AAAA-BBBB-CCCC-DDDD)." ::= { readingsEntry 2 } reNodeId3 OBJECT-TYPE SYNTAX Integer32 ( 0 .. 65536 ) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Node identifier, part 3 of 4 (16 bits, bits 31-16 of the id - part CCCC of AAAA-BBBB-CCCC-DDDD)." ::= { readingsEntry 3 } reNodeId4 OBJECT-TYPE SYNTAX Integer32 ( 0 .. 65536 ) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Node identifier, part 4 of 4 (16 bits, bits 15-0 of the id - part DDDD of AAAA-BBBB-CCCC-DDDD)." ::= { readingsEntry 4 } channelId OBJECT-TYPE SYNTAX INTEGER { current ( 2 ) , voltage ( 1 ) , power ( 3 ) , energy ( 4 ) , frequency ( 5 ) , temperature ( 6 ) , humidity ( 7 ) , va ( 8 ) , vdd ( 9 ) , battery ( 10 ) , pressure ( 11 ) , contact ( 12 ) , contactcount ( 13 ) } MAX-ACCESS not-accessible STATUS current DESCRIPTION "Channel ID, indicating the type of measurement reported." ::= { readingsEntry 5 } reNodeIdHex OBJECT-TYPE SYNTAX DisplayString ( SIZE ( 0 .. 16 ) ) MAX-ACCESS read-only STATUS current DESCRIPTION "Node ID number as as 16-character uppercase hexadecimal string." ::= { readingsEntry 6 } reNodeIdString OBJECT-TYPE SYNTAX DisplayString ( SIZE ( 0 .. 19 ) ) MAX-ACCESS read-only STATUS current DESCRIPTION "Node identifier (hex), formatted XXXX-XXXX-XXXX-XXXX (matches all Packet Power product labels)." ::= { readingsEntry 7 } reChannelName OBJECT-TYPE SYNTAX DisplayString ( SIZE ( 0 .. 255 ) ) MAX-ACCESS read-only STATUS current DESCRIPTION "Channel name, indicating channel type and instance (e.g.VoltageA)." ::= { readingsEntry 8 } reTime OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "Timestamp of the reading." ::= { readingsEntry 9 } reUnixTime OBJECT-TYPE SYNTAX Integer32 ( -2147483648 .. 2147483647 ) MAX-ACCESS read-only STATUS current DESCRIPTION "Reading timestamp, UNIX epoch format." ::= { readingsEntry 10 } reIso8601Time OBJECT-TYPE SYNTAX DisplayString ( SIZE ( 0 .. 255 ) ) MAX-ACCESS read-only STATUS current DESCRIPTION "Reading timestamp, ISO8601 format." ::= { readingsEntry 11 } reValue OBJECT-TYPE SYNTAX Integer32 ( -2147483648 .. 2147483647 ) MAX-ACCESS read-only STATUS current DESCRIPTION "Reading value at timestamp." ::= { readingsEntry 12 } reUnits OBJECT-TYPE SYNTAX DisplayString ( SIZE ( 0 .. 255 ) ) MAX-ACCESS read-only STATUS current DESCRIPTION "Units of measure." ::= { readingsEntry 13 } nodesTable OBJECT-TYPE SYNTAX SEQUENCE OF NodesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of all active nodes." ::= { eg4 2 } nodesEntry OBJECT-TYPE SYNTAX NodesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Node status, including most recent activity time and radio link quality." INDEX { ntNodeId1, ntNodeId2, ntNodeId3, ntNodeId4 } ::= { nodesTable 1 } NodesEntry ::= SEQUENCE { ntNodeId1 Integer32, ntNodeId2 Integer32, ntNodeId3 Integer32, ntNodeId4 Integer32, ntNodeIdHex DisplayString, ntNodeIdString DisplayString, ntTime DateAndTime, ntUnixTime Integer32, ntIso8601Time DisplayString, ntLinkQuality Integer32 } ntNodeId1 OBJECT-TYPE SYNTAX Integer32 ( 0 .. 65532 ) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Node identifier, part 1 of 4 (16 bits, bits 63-48 of the id - part AAAA of AAAA-BBBB-CCCC-DDDD)." ::= { nodesEntry 1 } ntNodeId2 OBJECT-TYPE SYNTAX Integer32 ( 0 .. 65532 ) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Node identifier, part 2 of 4 (16 bits, bits 47-32 of the id - part BBBB of AAAA-BBBB-CCCC-DDDD)." ::= { nodesEntry 2 } ntNodeId3 OBJECT-TYPE SYNTAX Integer32 ( 0 .. 65532 ) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Node identifier, part 3 of 4 (16 bits, bits 31-16 of the id - part CCCC of AAAA-BBBB-CCCC-DDDD)." ::= { nodesEntry 3 } ntNodeId4 OBJECT-TYPE SYNTAX Integer32 ( 0 .. 65532 ) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Node identifier, part 4 of 4 (16 bits, bits 15-0 of the id - part DDDD of AAAA-BBBB-CCCC-DDDD)." ::= { nodesEntry 4 } ntNodeIdHex OBJECT-TYPE SYNTAX DisplayString ( SIZE ( 0 .. 16 ) ) MAX-ACCESS read-only STATUS current DESCRIPTION "Node ID number as as 16-character uppercase hexadecimal string." ::= { nodesEntry 5 } ntNodeIdString OBJECT-TYPE SYNTAX DisplayString ( SIZE ( 0 .. 19 ) ) MAX-ACCESS read-only STATUS current DESCRIPTION "Node identifier (hex), formatted XXXX-XXXX-XXXX-XXXX (matches all Packet Power product labels)." ::= { nodesEntry 6 } ntTime OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "Timestamp of the most recent reading from the node." ::= { nodesEntry 7 } ntUnixTime OBJECT-TYPE SYNTAX Integer32 ( -2147483648 .. 2147483647 ) MAX-ACCESS read-only STATUS current DESCRIPTION "Timestamp of the most recent reading from the node, UNIX epoch format." ::= { nodesEntry 8 } ntIso8601Time OBJECT-TYPE SYNTAX DisplayString ( SIZE ( 0 .. 255 ) ) MAX-ACCESS read-only STATUS current DESCRIPTION "Timestamp of the most recent reading from the node, ISO8601 format." ::= { nodesEntry 9 } ntLinkQuality OBJECT-TYPE SYNTAX Integer32 ( 0 .. 100 ) MAX-ACCESS read-only STATUS current DESCRIPTION "Radio link quality 0..100" ::= { nodesEntry 10 } END