-- -- OPTIX-SONET-PER-MIB.mib -- MIB generated by MG-SOFT Visual MIB Builder Version 3.0 Build 253 -- Monday, March 06, 2006 at 10:26:16 -- -- ================================================================= -- Copyright (C) 2006 by HUAWEI TECHNOLOGIES. All rights reserved -- -- Description:This MIB describes the Performance interface of Huawei SONET transmit -- Reference: -- Version: V1.00 -- History: -- ,, -- ================================================================= -- OPTIX-SONET-PER-MIB DEFINITIONS ::= BEGIN IMPORTS optixCommonSonet FROM OPTIX-OID-MIB MOD2Type, PerformanceEventType, LocationType, DirectionType, ValidflagType FROM OPTIX-SONET-TC-MIB OBJECT-GROUP, MODULE-COMPLIANCE FROM SNMPv2-CONF Integer32, Unsigned32, OBJECT-TYPE, MODULE-IDENTITY FROM SNMPv2-SMI DateAndTime FROM SNMPv2-TC; optixSonetPerformance MODULE-IDENTITY LAST-UPDATED "200602250000Z" ORGANIZATION "Huawei Technologies co.,Ltd." CONTACT-INFO "R&D Building Huawei Technologies Co., Ltd. Bantian, Longgang District Shenzhen, P. R. China http://www.huawei.com Zip:518129 E-mail:support@huawei.com" DESCRIPTION "Description." REVISION "200602250000Z" DESCRIPTION "The initial revision of this MIB module." ::= { optixCommonSonet 20 } -- -- Node definitions -- -- Alarm data -- 1.3.6.1.4.1.2011.2.25.3.20.20.10 pmData OBJECT IDENTIFIER ::= { optixSonetPerformance 10 } -- ************************************************************************* -- Perfomance -- ------------------------------------------------------------------------- -- Perfomance 15-MIN Current Data Table (RTRV-PM-) -- ------------------------------------------------------------------------- -- 1.3.6.1.4.1.2011.2.25.3.20.20.10.10 per15mCurDataTable OBJECT-TYPE SYNTAX SEQUENCE OF Per15mCurDataEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "instructs an NE to send its current set of PM data associated with one or more equipment units, facilities, links, or signaling links within the NE." ::= { pmData 10 } -- EID, Such as CV-L, ES-S... -- NEND FEND -- RECV TRAN -- 1.3.6.1.4.1.2011.2.25.3.20.20.10.10.1 per15mCurDataEntry OBJECT-TYPE SYNTAX Per15mCurDataEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "instructs an NE to send its current set of PM data associated with one or more equipment units, facilities, links, or signaling links within the NE." INDEX { pm15mCurDataMOD2, pm15mCurDataSlot, pm15mCurDataPort, pm15mCurDataPath, pm15mCurDataVT, pm15mCurDataName, pm15mCurDataLocation, pm15mCurDataDirection } ::= { per15mCurDataTable 1 } Per15mCurDataEntry ::= SEQUENCE { pm15mCurDataMOD2 MOD2Type, pm15mCurDataSlot Unsigned32, pm15mCurDataPort Unsigned32, pm15mCurDataPath Unsigned32, pm15mCurDataVT Unsigned32, pm15mCurDataName PerformanceEventType, pm15mCurDataLocation LocationType, pm15mCurDataDirection DirectionType, pm15mCurDataMonVal Integer32, pm15mCurDataVldty ValidflagType, pm15mCurDataStartTime DateAndTime } -- 1.3.6.1.4.1.2011.2.25.3.20.20.10.10.1.1 pm15mCurDataMOD2 OBJECT-TYPE SYNTAX MOD2Type MAX-ACCESS read-only STATUS current DESCRIPTION "Signal mode." ::= { per15mCurDataEntry 1 } -- 1.3.6.1.4.1.2011.2.25.3.20.20.10.10.1.2 pm15mCurDataSlot OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Slot number. This will indicate what is the slot of the object which raised this PM data. If not relevant to the PM data, will be zero." ::= { per15mCurDataEntry 2 } -- 1.3.6.1.4.1.2011.2.25.3.20.20.10.10.1.3 pm15mCurDataPort OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Port number. This will indicate what is the Port of the object which raised this PM data. If not relevant to the PM data, will be zero. " ::= { per15mCurDataEntry 3 } -- 1.3.6.1.4.1.2011.2.25.3.20.20.10.10.1.4 pm15mCurDataPath OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Path number. This will indicate what is the Path of the object which raised this PM data. If not relevant to the PM data, will be zero. " ::= { per15mCurDataEntry 4 } -- 1.3.6.1.4.1.2011.2.25.3.20.20.10.10.1.5 pm15mCurDataVT OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "VT path number. This will indicate what is the VT path of the object which raised this PM data. If not relevant to the PM data, will be zero. " ::= { per15mCurDataEntry 5 } -- 1.3.6.1.4.1.2011.2.25.3.20.20.10.10.1.6 pm15mCurDataName OBJECT-TYPE SYNTAX PerformanceEventType MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the type of monitored parameter for which a value is retrieved." ::= { per15mCurDataEntry 6 } -- 1.3.6.1.4.1.2011.2.25.3.20.20.10.10.1.7 pm15mCurDataLocation OBJECT-TYPE SYNTAX LocationType MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the location. Only NEND(Near end)|FEND(Far end)|ALL will be represented here." ::= { per15mCurDataEntry 7 } -- 1.3.6.1.4.1.2011.2.25.3.20.20.10.10.1.8 pm15mCurDataDirection OBJECT-TYPE SYNTAX DirectionType MAX-ACCESS read-only STATUS current DESCRIPTION "specifies the direction of monitoring. Only RCV(Receive direction)|TRMT(Transmit direction)|ALL will be represented here." ::= { per15mCurDataEntry 8 } -- 1.3.6.1.4.1.2011.2.25.3.20.20.10.10.1.9 pm15mCurDataMonVal OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Measured value." ::= { per15mCurDataEntry 9 } -- 1.3.6.1.4.1.2011.2.25.3.20.20.10.10.1.10 pm15mCurDataVldty OBJECT-TYPE SYNTAX ValidflagType MAX-ACCESS read-only STATUS current DESCRIPTION "It indicates whether the information for the specified time period was accumulated over the entire time period or some portion of it. Only INVALID|VALID will be represented here." ::= { per15mCurDataEntry 10 } -- 1.3.6.1.4.1.2011.2.25.3.20.20.10.10.1.11 pm15mCurDataStartTime OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "The beginning date and time of the PM period." ::= { per15mCurDataEntry 11 } -- ------------------------------------------------------------------------- -- Perfomance 15-MIN History Data Table (RTRV-PM-) -- ------------------------------------------------------------------------- -- 1.3.6.1.4.1.2011.2.25.3.20.20.10.20 per15mHisDataTable OBJECT-TYPE SYNTAX SEQUENCE OF Per15mHisDataEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "instructs an NE to send its history set of PM data associated with one or more equipment units, facilities, links, or signaling links within the NE." ::= { pmData 20 } -- EID, Such as CV-L, ES-S... -- NEND FEND -- RECV TRAN -- Period number -- 1.3.6.1.4.1.2011.2.25.3.20.20.10.20.1 per15mHisDataEntry OBJECT-TYPE SYNTAX Per15mHisDataEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "instructs an NE to send its history set of PM data associated with one or more equipment units, facilities, links, or signaling links within the NE." INDEX { pm15mHisDataMOD2, pm15mHisDataSlot, pm15mHisDataPort, pm15mHisDataPath, pm15mHisDataVT, pm15mHisDataName, pm15mHisDataLocation, pm15mHisDataDirection, pm15mHisDataInterval } ::= { per15mHisDataTable 1 } Per15mHisDataEntry ::= SEQUENCE { pm15mHisDataMOD2 MOD2Type, pm15mHisDataSlot Unsigned32, pm15mHisDataPort Unsigned32, pm15mHisDataPath Unsigned32, pm15mHisDataVT Unsigned32, pm15mHisDataName PerformanceEventType, pm15mHisDataLocation LocationType, pm15mHisDataDirection DirectionType, pm15mHisDataInterval Unsigned32, pm15mHisDataMonVal Integer32, pm15mHisDataVldty ValidflagType, pm15mHisDataStartTime DateAndTime } -- 1.3.6.1.4.1.2011.2.25.3.20.20.10.20.1.1 pm15mHisDataMOD2 OBJECT-TYPE SYNTAX MOD2Type MAX-ACCESS read-only STATUS current DESCRIPTION "Signal mode." ::= { per15mHisDataEntry 1 } -- 1.3.6.1.4.1.2011.2.25.3.20.20.10.20.1.2 pm15mHisDataSlot OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Slot number. This will indicate what is the slot of the object which raised this PM data. If not relevant to the PM data, will be zero." ::= { per15mHisDataEntry 2 } -- 1.3.6.1.4.1.2011.2.25.3.20.20.10.20.1.3 pm15mHisDataPort OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Port number. This will indicate what is the Port of the object which raised this PM data. If not relevant to the PM data, will be zero. " ::= { per15mHisDataEntry 3 } -- 1.3.6.1.4.1.2011.2.25.3.20.20.10.20.1.4 pm15mHisDataPath OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Path number. This will indicate what is the Path of the object which raised this PM data. If not relevant to the PM data, will be zero. " ::= { per15mHisDataEntry 4 } -- 1.3.6.1.4.1.2011.2.25.3.20.20.10.20.1.5 pm15mHisDataVT OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "VT path number. This will indicate what is the VT path of the object which raised this PM data. If not relevant to the PM data, will be zero. " ::= { per15mHisDataEntry 5 } -- 1.3.6.1.4.1.2011.2.25.3.20.20.10.20.1.6 pm15mHisDataName OBJECT-TYPE SYNTAX PerformanceEventType MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the type of monitored parameter for which a value is retrieved." ::= { per15mHisDataEntry 6 } -- 1.3.6.1.4.1.2011.2.25.3.20.20.10.20.1.7 pm15mHisDataLocation OBJECT-TYPE SYNTAX LocationType MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the location. Only NEND(Near end)|FEND(Far end)|ALL will be represented here." ::= { per15mHisDataEntry 7 } -- 1.3.6.1.4.1.2011.2.25.3.20.20.10.20.1.8 pm15mHisDataDirection OBJECT-TYPE SYNTAX DirectionType MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies the direction of monitoring. Only RCV(Receive direction)|TRMT(Transmit direction)|ALL will be represented here." ::= { per15mHisDataEntry 8 } -- 1.3.6.1.4.1.2011.2.25.3.20.20.10.20.1.9 pm15mHisDataInterval OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The period number." ::= { per15mHisDataEntry 9 } -- 1.3.6.1.4.1.2011.2.25.3.20.20.10.20.1.10 pm15mHisDataMonVal OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Measured value." ::= { per15mHisDataEntry 10 } -- 1.3.6.1.4.1.2011.2.25.3.20.20.10.20.1.11 pm15mHisDataVldty OBJECT-TYPE SYNTAX ValidflagType MAX-ACCESS read-only STATUS current DESCRIPTION "It indicates whether the information for the specified time period was accumulated over the entire time period or some portion of it. Only INVALID|VALID will be represented here." ::= { per15mHisDataEntry 11 } -- 1.3.6.1.4.1.2011.2.25.3.20.20.10.20.1.12 pm15mHisDataStartTime OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "The beginning date and time of the PM period." ::= { per15mHisDataEntry 12 } -- ------------------------------------------------------------------------- -- Perfomance 1-DAY Current Data Table (RTRV-PM-) -- ------------------------------------------------------------------------- -- 1.3.6.1.4.1.2011.2.25.3.20.20.10.30 per1dayCurDataTable OBJECT-TYPE SYNTAX SEQUENCE OF Per1dayCurDataEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "instructs an NE to send its current set of PM data associated with one or more equipment units, facilities, links, or signaling links within the NE." ::= { pmData 30 } -- EID, Such as CV-L, ES-S... -- NEND FEND -- RECV TRAN -- 1.3.6.1.4.1.2011.2.25.3.20.20.10.30.1 per1dayCurDataEntry OBJECT-TYPE SYNTAX Per1dayCurDataEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "instructs an NE to send its current set of PM data associated with one or more equipment units, facilities, links, or signaling links within the NE." INDEX { pm1dayCurDataMOD2, pm1dayCurDataSlot, pm1dayCurDataPort, pm1dayCurDataPath, pm1dayCurDataVT, pm1dayCurDataName, pm1dayCurDataLocation, pm1dayCurDataDirection } ::= { per1dayCurDataTable 1 } Per1dayCurDataEntry ::= SEQUENCE { pm1dayCurDataMOD2 MOD2Type, pm1dayCurDataSlot Unsigned32, pm1dayCurDataPort Unsigned32, pm1dayCurDataPath Unsigned32, pm1dayCurDataVT Unsigned32, pm1dayCurDataName PerformanceEventType, pm1dayCurDataLocation LocationType, pm1dayCurDataDirection DirectionType, pm1dayCurDataMonVal Integer32, pm1dayCurDataVldty ValidflagType, pm1dayCurDataStartTime DateAndTime } -- 1.3.6.1.4.1.2011.2.25.3.20.20.10.30.1.1 pm1dayCurDataMOD2 OBJECT-TYPE SYNTAX MOD2Type MAX-ACCESS read-only STATUS current DESCRIPTION "Signal mode." ::= { per1dayCurDataEntry 1 } -- 1.3.6.1.4.1.2011.2.25.3.20.20.10.30.1.2 pm1dayCurDataSlot OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Slot number. This will indicate what is the slot of the object which raised this PM data. If not relevant to the PM data, will be zero." ::= { per1dayCurDataEntry 2 } -- 1.3.6.1.4.1.2011.2.25.3.20.20.10.30.1.3 pm1dayCurDataPort OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Port number. This will indicate what is the Port of the object which raised this PM data. If not relevant to the PM data, will be zero. " ::= { per1dayCurDataEntry 3 } -- 1.3.6.1.4.1.2011.2.25.3.20.20.10.30.1.4 pm1dayCurDataPath OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Path number. This will indicate what is the Path of the object which raised this PM data. If not relevant to the PM data, will be zero. " ::= { per1dayCurDataEntry 4 } -- 1.3.6.1.4.1.2011.2.25.3.20.20.10.30.1.5 pm1dayCurDataVT OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "VT path number. This will indicate what is the VT path of the object which raised this PM data. If not relevant to the PM data, will be zero. " ::= { per1dayCurDataEntry 5 } -- 1.3.6.1.4.1.2011.2.25.3.20.20.10.30.1.6 pm1dayCurDataName OBJECT-TYPE SYNTAX PerformanceEventType MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the type of monitored parameter for which a value is retrieved." ::= { per1dayCurDataEntry 6 } -- 1.3.6.1.4.1.2011.2.25.3.20.20.10.30.1.7 pm1dayCurDataLocation OBJECT-TYPE SYNTAX LocationType MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the location. Only NEND(Near end)|FEND(Far end)|ALL will be represented here." ::= { per1dayCurDataEntry 7 } -- 1.3.6.1.4.1.2011.2.25.3.20.20.10.30.1.8 pm1dayCurDataDirection OBJECT-TYPE SYNTAX DirectionType MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies the direction of monitoring. Only RCV(Receive direction)|TRMT(Transmit direction)|ALL will be represented here." ::= { per1dayCurDataEntry 8 } -- 1.3.6.1.4.1.2011.2.25.3.20.20.10.30.1.9 pm1dayCurDataMonVal OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "measured value." ::= { per1dayCurDataEntry 9 } -- 1.3.6.1.4.1.2011.2.25.3.20.20.10.30.1.10 pm1dayCurDataVldty OBJECT-TYPE SYNTAX ValidflagType MAX-ACCESS read-only STATUS current DESCRIPTION "It indicates whether the information for the specified time period was accumulated over the entire time period or some portion of it. Only INVALID|VALID will be represented here." ::= { per1dayCurDataEntry 10 } -- 1.3.6.1.4.1.2011.2.25.3.20.20.10.30.1.11 pm1dayCurDataStartTime OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "The beginning date and time of the PM period." ::= { per1dayCurDataEntry 11 } -- ------------------------------------------------------------------------- -- Perfomance 1-DAY History Data Table (RTRV-PM-) -- ------------------------------------------------------------------------- -- 1.3.6.1.4.1.2011.2.25.3.20.20.10.40 per1dayHisDataTable OBJECT-TYPE SYNTAX SEQUENCE OF Per1dayHisDataEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "instructs an NE to send its history set of PM data associated with one or more equipment units, facilities, links, or signaling links within the NE." ::= { pmData 40 } -- EID, Such as CV-L, ES-S... -- NEND FEND -- RECV TRAN -- Period number -- 1.3.6.1.4.1.2011.2.25.3.20.20.10.40.1 per1dayHisDataEntry OBJECT-TYPE SYNTAX Per1dayHisDataEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "instructs an NE to send its history set of PM data associated with one or more equipment units, facilities, links, or signaling links within the NE." INDEX { pm1dayHisDataMOD2, pm1dayHisDataSlot, pm1dayHisDataPort, pm1dayHisDataPath, pm1dayHisDataVT, pm1dayHisDataName, pm1dayHisDataLocation, pm1dayHisDataDirection, pm1dayHisDataInterval } ::= { per1dayHisDataTable 1 } Per1dayHisDataEntry ::= SEQUENCE { pm1dayHisDataMOD2 MOD2Type, pm1dayHisDataSlot Unsigned32, pm1dayHisDataPort Unsigned32, pm1dayHisDataPath Unsigned32, pm1dayHisDataVT Unsigned32, pm1dayHisDataName PerformanceEventType, pm1dayHisDataLocation LocationType, pm1dayHisDataDirection DirectionType, pm1dayHisDataInterval Unsigned32, pm1dayHisDataMonVal Integer32, pm1dayHisDataVldty ValidflagType, pm1dayHisDataStartTime DateAndTime } -- 1.3.6.1.4.1.2011.2.25.3.20.20.10.40.1.1 pm1dayHisDataMOD2 OBJECT-TYPE SYNTAX MOD2Type MAX-ACCESS read-only STATUS current DESCRIPTION "Signal mode." ::= { per1dayHisDataEntry 1 } -- 1.3.6.1.4.1.2011.2.25.3.20.20.10.40.1.2 pm1dayHisDataSlot OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Slot number. This will indicate what is the slot of the object which raised this PM data. If not relevant to the PM data, will be zero." ::= { per1dayHisDataEntry 2 } -- 1.3.6.1.4.1.2011.2.25.3.20.20.10.40.1.3 pm1dayHisDataPort OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Port number. This will indicate what is the Port of the object which raised this PM data. If not relevant to the PM data, will be zero. " ::= { per1dayHisDataEntry 3 } -- 1.3.6.1.4.1.2011.2.25.3.20.20.10.40.1.4 pm1dayHisDataPath OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Path number. This will indicate what is the Path of the object which raised this PM data. If not relevant to the PM data, will be zero. " ::= { per1dayHisDataEntry 4 } -- 1.3.6.1.4.1.2011.2.25.3.20.20.10.40.1.5 pm1dayHisDataVT OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "VT path number. This will indicate what is the VT path of the object which raised this PM data. If not relevant to the PM data, will be zero. " ::= { per1dayHisDataEntry 5 } -- 1.3.6.1.4.1.2011.2.25.3.20.20.10.40.1.6 pm1dayHisDataName OBJECT-TYPE SYNTAX PerformanceEventType MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the type of monitored parameter for which a value is retrieved." ::= { per1dayHisDataEntry 6 } -- 1.3.6.1.4.1.2011.2.25.3.20.20.10.40.1.7 pm1dayHisDataLocation OBJECT-TYPE SYNTAX LocationType MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the location. Only NEND(Near end)|FEND(Far end)|ALL will be represented here." ::= { per1dayHisDataEntry 7 } -- 1.3.6.1.4.1.2011.2.25.3.20.20.10.40.1.8 pm1dayHisDataDirection OBJECT-TYPE SYNTAX DirectionType MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies the direction of monitoring. Only RCV(Receive direction)|TRMT(Transmit direction)|ALL will be represented here." ::= { per1dayHisDataEntry 8 } -- 1.3.6.1.4.1.2011.2.25.3.20.20.10.40.1.9 pm1dayHisDataInterval OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The period number." ::= { per1dayHisDataEntry 9 } -- 1.3.6.1.4.1.2011.2.25.3.20.20.10.40.1.10 pm1dayHisDataMonVal OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Measured value." ::= { per1dayHisDataEntry 10 } -- 1.3.6.1.4.1.2011.2.25.3.20.20.10.40.1.11 pm1dayHisDataVldty OBJECT-TYPE SYNTAX ValidflagType MAX-ACCESS read-only STATUS current DESCRIPTION "It indicates whether the information for the specified time period was accumulated over the entire time period or some portion of it. Only INVALID|VALID will be represented here." ::= { per1dayHisDataEntry 11 } -- 1.3.6.1.4.1.2011.2.25.3.20.20.10.40.1.12 pm1dayHisDataStartTime OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "The beginning date and time of the PM period." ::= { per1dayHisDataEntry 12 } -- 1.3.6.1.4.1.2011.2.25.3.20.20.20 optixSonetPmConformance OBJECT IDENTIFIER ::= { optixSonetPerformance 20 } -- 1.3.6.1.4.1.2011.2.25.3.20.20.20.1 optixSonetPmGroups OBJECT IDENTIFIER ::= { optixSonetPmConformance 1 } -- 1.3.6.1.4.1.2011.2.25.3.20.20.20.1.1 optixSonetPmObjectGroup OBJECT-GROUP OBJECTS { pm15mCurDataMOD2, pm15mCurDataSlot, pm15mCurDataPort, pm15mCurDataPath, pm15mCurDataVT, pm15mCurDataName, pm15mCurDataLocation, pm15mCurDataDirection, pm15mCurDataMonVal, pm15mCurDataVldty, pm15mCurDataStartTime, pm15mHisDataMOD2, pm15mHisDataSlot, pm15mHisDataPort, pm15mHisDataPath, pm15mHisDataVT, pm15mHisDataName, pm15mHisDataLocation, pm15mHisDataDirection, pm15mHisDataInterval, pm15mHisDataMonVal, pm15mHisDataVldty, pm15mHisDataStartTime, pm1dayCurDataMOD2, pm1dayCurDataSlot, pm1dayCurDataPort, pm1dayCurDataPath, pm1dayCurDataVT, pm1dayCurDataName, pm1dayCurDataLocation, pm1dayCurDataDirection, pm1dayCurDataMonVal, pm1dayCurDataVldty, pm1dayCurDataStartTime, pm1dayHisDataMOD2, pm1dayHisDataSlot, pm1dayHisDataPort, pm1dayHisDataPath, pm1dayHisDataVT, pm1dayHisDataName, pm1dayHisDataLocation, pm1dayHisDataDirection, pm1dayHisDataInterval, pm1dayHisDataMonVal, pm1dayHisDataVldty, pm1dayHisDataStartTime } STATUS current DESCRIPTION "Enter the description of the created OBJECT-GROUP." ::= { optixSonetPmGroups 1 } -- 1.3.6.1.4.1.2011.2.25.3.20.20.20.2 optixSonetPmCompliances OBJECT IDENTIFIER ::= { optixSonetPmConformance 2 } -- 1.3.6.1.4.1.2011.2.25.3.20.20.20.2.1 optixSonetPmBasicCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "Enter the description of the created MODULE-COMPLIANCE." MODULE -- this module MANDATORY-GROUPS { optixSonetPmObjectGroup } ::= { optixSonetPmCompliances 1 } END -- -- OPTIX-SONET-PER-MIB.mib --