-- -- OPTIX-SONET-PATH-MIB-V2.mib -- MIB generated by MG-SOFT Visual MIB Builder Version 3.0 Build 253 -- Wednesday, July 26, 2006 at 17:18:08 -- OPTIX-SONET-PATH-MIB-V2 DEFINITIONS ::= BEGIN IMPORTS optixProvisionSonet FROM OPTIX-OID-MIB OBJECT-GROUP, MODULE-COMPLIANCE FROM SNMPv2-CONF Gauge32, OBJECT-TYPE, MODULE-IDENTITY FROM SNMPv2-SMI TEXTUAL-CONVENTION FROM SNMPv2-TC; optixsonetPathAttrib MODULE-IDENTITY LAST-UPDATED "200605261729Z" -- May 26, 2006 at 17:29 GMT ORGANIZATION "Your organization" CONTACT-INFO "Your contact info" DESCRIPTION "Enter the description for this MIB module." ::= { optixProvisionSonet 5 } -- -- Textual conventions -- C2Value ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Enter the description for the C2Value TEXTUAL-CONVENTION converted from type assignment." SYNTAX INTEGER { eqpd(1), vt-sts1(2), lock-vt(3), ds3(4), ds4na(18), atm(19), dqdb(20), fddi(21), hdlc-over-sonet(22), laps(24), gfp(27), pdi-1(225), pdi-2(226), pdi-3(227), pdi-4(228), pdi-5(229), pdi-6(230), pdi-7(231), pdi-8(232), pdi-9(233), pdi-10(234), pdi-11(235), pdi-12(236), pdi-13(237), pdi-14(238), pdi-15(239), pdi-16(240), pdi-17(241), pdi-18(242), pdi-19(243), pdi-20(244), pdi-21(245), pdi-22(246), pdi-23(247), pdi-24(248), pdi-29(249), pdi-26(250), pdi-27(251), pdi-28(252), uneq(253), o-181(254), invalid(65534) } LpbkType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Enter the description for the LpbkType TEXTUAL-CONVENTION converted from type assignment." SYNTAX INTEGER { terminal(1), facility(2), crs(3), ds1feac(4), ds3feac(5), fac2ni(6), noloop(255) } -- -- Node definitions -- -- 1.3.6.1.4.1.2011.2.25.4.20.5.1 optixsonetStsPathTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixsonetStsPathEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table describes the STS path management interface of Huawei SONET transmit platform " ::= { optixsonetPathAttrib 1 } -- 1.3.6.1.4.1.2011.2.25.4.20.5.1.1 optixsonetStsPathEntry OBJECT-TYPE SYNTAX OptixsonetStsPathEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The STS path management entry " INDEX { stsPathLevel, stsPathBid, stsPathPid, stsPathStsId } ::= { optixsonetStsPathTable 1 } OptixsonetStsPathEntry ::= SEQUENCE { stsPathLevel INTEGER, stsPathBid Gauge32, stsPathPid Gauge32, stsPathStsId Gauge32, stsPathRevertiveMode INTEGER, stsPathRevertiveTime Gauge32, stsPathSwitchConditon INTEGER, stsPathDelayTime Gauge32, stsPathSFBER INTEGER, stsPathSDBER INTEGER, stsPathJ1TRCMODE INTEGER, stsPathTRCJ1 OCTET STRING, stsPathEXPTRCJ1 OCTET STRING, stsPathINCTRCJ1 OCTET STRING, stsPathTRCC2 C2Value, stsPathEXPTRCC2 C2Value, stsPathINCTRCC2 C2Value, stsPathSQL INTEGER, stsPathSwitchState INTEGER, stsPathPST OCTET STRING, stsPathSST OCTET STRING, stsPathLoopbackStatus LpbkType } -- 1.3.6.1.4.1.2011.2.25.4.20.5.1.1.1 stsPathLevel OBJECT-TYPE SYNTAX INTEGER { levelSTS1(9), levelSTS3c(10), levelSTS6c(11), levelSTS9c(12), levelSTS12c(13), levelSTS15c(14), levelSTS24c(15), levelSTS48c(16), levelSTS192c(17) } MAX-ACCESS read-only STATUS current DESCRIPTION "The path level that identifies the type of STS path." ::= { optixsonetStsPathEntry 1 } -- 1.3.6.1.4.1.2011.2.25.4.20.5.1.1.2 stsPathBid OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Slot number. This will indicate what is the slot of the object." ::= { optixsonetStsPathEntry 2 } -- 1.3.6.1.4.1.2011.2.25.4.20.5.1.1.3 stsPathPid OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Port Number. This will indicate what is the Port of the object. " ::= { optixsonetStsPathEntry 3 } -- 1.3.6.1.4.1.2011.2.25.4.20.5.1.1.4 stsPathStsId OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Sts Number. This will indicate what is the Sts of the object." ::= { optixsonetStsPathEntry 4 } -- 1.3.6.1.4.1.2011.2.25.4.20.5.1.1.5 stsPathRevertiveMode OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2), null(254) } MAX-ACCESS read-write STATUS current DESCRIPTION "A revertive mode. It only applies to UPSR.Valid values are shown below. Value Description Y Revertive mode. N No-revertive mode. " ::= { optixsonetStsPathEntry 5 } -- 1.3.6.1.4.1.2011.2.25.4.20.5.1.1.6 stsPathRevertiveTime OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-write STATUS current DESCRIPTION "Revertive time. It only applies to UPSR.Valid values are shown below. Value Description 5 to 12 Revertive time of UPSR, ranging from 5 to 12 minutes, default is 5 minutes, in increments of 1 minute. " ::= { optixsonetStsPathEntry 6 } -- 1.3.6.1.4.1.2011.2.25.4.20.5.1.1.7 stsPathSwitchConditon OBJECT-TYPE SYNTAX INTEGER { no(1), yes(2), null(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Optional switching condition. Valid value is Y (switch when existing PDI-P) or N (do not switch when existing PDI-P).Default value is N." ::= { optixsonetStsPathEntry 7 } -- 1.3.6.1.4.1.2011.2.25.4.20.5.1.1.8 stsPathDelayTime OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-write STATUS current DESCRIPTION "Delay time is hold-off time. It is an integer. Valid value ranges from 0 to 255. Unit is 100 ms. Default value is 0.Delay times are useful for interworking of protection schemes. For example, an optical port is configured for both UPSR and BLSR simultaneously. After the delay time is set, when a defect condition is declared on the port, the UPSR switching is not initiated. When the timer expires, the UPSR switching is initiated if the defect condition is still present at this point. When only one kind of protection UPSR is configured, just use the default value. " ::= { optixsonetStsPathEntry 8 } -- 1.3.6.1.4.1.2011.2.25.4.20.5.1.1.9 stsPathSFBER OBJECT-TYPE SYNTAX INTEGER { sf1E-3(3), sf1E-4(4), sf1E-5(5) } MAX-ACCESS read-write STATUS current DESCRIPTION "Threshold of path (B3) SFBER on a facility. Valid values are shown below. Value Description 1E-3 to 1E-5 SFBER ranges from 1E-3 to 1E-5, Default threshold is 1E-4. 1E-5 to 1E-9 SDBER ranges from 1E-5 to 1E-9, Default threshold is 1E-6. " ::= { optixsonetStsPathEntry 9 } -- 1.3.6.1.4.1.2011.2.25.4.20.5.1.1.10 stsPathSDBER OBJECT-TYPE SYNTAX INTEGER { sd1E-5(5), sd1E-6(6), sd1E-7(7), sd1E-8(8), sd1E-9(9) } MAX-ACCESS read-write STATUS current DESCRIPTION "Threshold of path (B3) SDBER on a facility. Valid values are shown below. Value Description 1E-3 to 1E-5 SFBER ranges from 1E-3 to 1E-5, Default threshold is 1E-4. 1E-5 to 1E-9 SDBER ranges from 1E-5 to 1E-9, Default threshold is 1E-6." ::= { optixsonetStsPathEntry 10 } -- 1.3.6.1.4.1.2011.2.25.4.20.5.1.1.11 stsPathJ1TRCMODE OBJECT-TYPE SYNTAX INTEGER { manual(1), auto(2), off(3), invalid(254) } MAX-ACCESS read-write STATUS current DESCRIPTION "Path trace mode. Valid values are shown below. Value Description MANUAL Performs the comparison of the received string with the user-entered expected string. AUTO Performs the comparison of the present received string with an expected string set to a previously received string. If there is a mismatch, TIM-P alarm is raised. OFF Don't perform the comparison. Default value is OFF. " ::= { optixsonetStsPathEntry 11 } -- 1.3.6.1.4.1.2011.2.25.4.20.5.1.1.12 stsPathTRCJ1 OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..62)) MAX-ACCESS read-write STATUS current DESCRIPTION "The path trace message contents (J1) to be transmitted." ::= { optixsonetStsPathEntry 12 } -- 1.3.6.1.4.1.2011.2.25.4.20.5.1.1.13 stsPathEXPTRCJ1 OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..62)) MAX-ACCESS read-write STATUS current DESCRIPTION "The expected path traces message (J1) contents." ::= { optixsonetStsPathEntry 13 } -- 1.3.6.1.4.1.2011.2.25.4.20.5.1.1.14 stsPathINCTRCJ1 OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..62)) MAX-ACCESS read-only STATUS current DESCRIPTION "The path trace message received. It can not include escape characters except \ and . " ::= { optixsonetStsPathEntry 14 } -- 1.3.6.1.4.1.2011.2.25.4.20.5.1.1.15 stsPathTRCC2 OBJECT-TYPE SYNTAX C2Value MAX-ACCESS read-write STATUS current DESCRIPTION "The C2 byte hex code to be transmitted. Valid values are shown below. Value Description UNEQ 0x00 The C2 content to be transmitted is unloaded. EQPD (default) 0x01 The C2 content to be transmitted is loaded with normal SPE. VT-STS1 0x02 The C2 content to be transmitted: STS-1 SPE of VT structure. Default value for C2 in DS1 unit LOCK-VT 0x03 The C2 content to be transmitted: lock VT mode. DS3 0x04 The C2 content to be transmitted: DS3 asynchronous mapping. Default value for C2 in DS3 port. DS4NA 0x12 The C2 content to be transmitted: DS4NA asynchronous mapping. ATM 0x13 The C2 content to be transmitted: ATM mapping. DQDB 0x14 The C2 content to be transmitted: DQDB mapping. FDDI 0x15 The C2 content to be transmitted: FDDI asynchronous mapping. HDLC-OVER-SONET 0x16 The C2 content to be transmitted: HDLC-OVER-SONET mapping. LAPS 0x18 GFP 0x1b O.181 0xfe The C2 content to be transmitted: O.181 testing signal. Other byte Hex code Non standard C2. " ::= { optixsonetStsPathEntry 15 } -- 1.3.6.1.4.1.2011.2.25.4.20.5.1.1.16 stsPathEXPTRCC2 OBJECT-TYPE SYNTAX C2Value MAX-ACCESS read-write STATUS current DESCRIPTION "The expected C2 byte hex code. Valid values are shown below. Value Description UNEQ 0x00 The C2 content to be transmitted is unloaded. EQPD (default) 0x01 The C2 content to be transmitted is loaded with normal SPE. VT-STS1 0x02 The C2 content to be transmitted: STS-1 SPE of VT structure. Default value for C2 in DS1 unit LOCK-VT 0x03 The C2 content to be transmitted: lock VT mode. DS3 0x04 The C2 content to be transmitted: DS3 asynchronous mapping. Default value for C2 in DS3 port. DS4NA 0x12 The C2 content to be transmitted: DS4NA asynchronous mapping. ATM 0x13 The C2 content to be transmitted: ATM mapping. DQDB 0x14 The C2 content to be transmitted: DQDB mapping. FDDI 0x15 The C2 content to be transmitted: FDDI asynchronous mapping. HDLC-OVER-SONET 0x16 The C2 content to be transmitted: HDLC-OVER-SONET mapping. LAPS 0x18 GFP 0x1b O.181 0xfe The C2 content to be transmitted: O.181 testing signal. Other byte Hex code Non standard C2. " ::= { optixsonetStsPathEntry 16 } -- 1.3.6.1.4.1.2011.2.25.4.20.5.1.1.17 stsPathINCTRCC2 OBJECT-TYPE SYNTAX C2Value MAX-ACCESS read-only STATUS current DESCRIPTION "The C2 byte hex code received. Valid values are shown below. Value Description UNEQ 0x00 The C2 content to be transmitted is unloaded. EQPD (default) 0x01 The C2 content to be transmitted is loaded with normal SPE. VT-STS1 0x02 The C2 content to be transmitted: STS-1 SPE of VT structure. Default value for C2 in DS1 unit LOCK-VT 0x03 The C2 content to be transmitted: lock VT mode. DS3 0x04 The C2 content to be transmitted: DS3 asynchronous mapping. Default value for C2 in DS3 port. DS4NA 0x12 The C2 content to be transmitted: DS4NA asynchronous mapping. ATM 0x13 The C2 content to be transmitted: ATM mapping. DQDB 0x14 The C2 content to be transmitted: DQDB mapping. FDDI 0x15 The C2 content to be transmitted: FDDI asynchronous mapping. HDLC-OVER-SONET 0x16 The C2 content to be transmitted: HDLC-OVER-SONET mapping. LAPS 0x18 GFP 0x1b O.181 0xfe The C2 content to be transmitted: O.181 testing signal. Other byte Hex code Non standard C2. " ::= { optixsonetStsPathEntry 17 } -- 1.3.6.1.4.1.2011.2.25.4.20.5.1.1.18 stsPathSQL OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2), invalid(254) } MAX-ACCESS read-only STATUS current DESCRIPTION "The flag of squelch. This parameter only supplies for BLSR. Valid value is Y or N." ::= { optixsonetStsPathEntry 18 } -- 1.3.6.1.4.1.2011.2.25.4.20.5.1.1.19 stsPathSwitchState OBJECT-TYPE SYNTAX INTEGER { wtr(1), autosw(2), manPtoW(3), manWtoP(4), frcPtoW(5), frcWtoP(6), lockout(7), clear(8), idle(253), invalid(254) } MAX-ACCESS read-only STATUS current DESCRIPTION "It is only valid when the port is in the UPSR protection group. Valid values are shown below. Value Description IDLE Idle WTR Wait to restore AUTOSW Automatic switch MANPtoW Manually switch to the working unit MANWtoP Manually switch to the protecting unit FRCPtoW Forced switch to the working unit FRCWtoP Forced switch to the protecting unit LOCKOUT Lock to the working unit CLEAR Clear INVALID Invalid " ::= { optixsonetStsPathEntry 19 } -- 1.3.6.1.4.1.2011.2.25.4.20.5.1.1.20 stsPathPST OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..16)) MAX-ACCESS read-write STATUS current DESCRIPTION " means the primary state of the entity. Valid values are IS-NR, OOS-AU, OOS-MA and OOS-AUMA." ::= { optixsonetStsPathEntry 20 } -- 1.3.6.1.4.1.2011.2.25.4.20.5.1.1.21 stsPathSST OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..32)) MAX-ACCESS read-write STATUS current DESCRIPTION " means the secondary state of the entity. Valid values are MT, LPBK, SGEO and FAF," ::= { optixsonetStsPathEntry 21 } -- 1.3.6.1.4.1.2011.2.25.4.20.5.1.1.22 stsPathLoopbackStatus OBJECT-TYPE SYNTAX LpbkType MAX-ACCESS read-write STATUS current DESCRIPTION "This variable represents the current state of the loopback on the sts path. " ::= { optixsonetStsPathEntry 22 } -- 1.3.6.1.4.1.2011.2.25.4.20.5.2 optixsonetPathAttribConformance OBJECT IDENTIFIER ::= { optixsonetPathAttrib 2 } -- 1.3.6.1.4.1.2011.2.25.4.20.5.2.1 optixsonetPathAttribGroups OBJECT IDENTIFIER ::= { optixsonetPathAttribConformance 1 } -- 1.3.6.1.4.1.2011.2.25.4.20.5.2.1.1 currentObjectGroup OBJECT-GROUP OBJECTS { stsPathLevel, stsPathBid, stsPathPid, stsPathStsId, stsPathRevertiveMode, stsPathRevertiveTime, stsPathSwitchConditon, stsPathDelayTime, stsPathSFBER, stsPathSDBER, stsPathJ1TRCMODE, stsPathTRCJ1, stsPathEXPTRCJ1, stsPathINCTRCJ1, stsPathTRCC2, stsPathEXPTRCC2, stsPathINCTRCC2, stsPathSQL, stsPathSwitchState, stsPathPST, stsPathSST, stsPathLoopbackStatus } STATUS current DESCRIPTION "Enter the description of the created OBJECT-GROUP." ::= { optixsonetPathAttribGroups 1 } -- 1.3.6.1.4.1.2011.2.25.4.20.5.2.2 optixsonetPathAttribCompliances OBJECT IDENTIFIER ::= { optixsonetPathAttribConformance 2 } -- 1.3.6.1.4.1.2011.2.25.4.20.5.2.2.1 basicCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "Enter the description of the created MODULE-COMPLIANCE." MODULE -- this module MANDATORY-GROUPS { currentObjectGroup } ::= { optixsonetPathAttribCompliances 1 } END -- -- OPTIX-SONET-PATH-MIB-V2.mib --