-- -- OPTIX-SONET-EQPTMGT-MIB-V2.mib -- MIB generated by MG-SOFT Visual MIB Builder Version 3.0 Build 253 -- Wednesday, July 26, 2006 at 17:16:46 -- OPTIX-SONET-EQPTMGT-MIB-V2 DEFINITIONS ::= BEGIN IMPORTS optixProvisionSonet FROM OPTIX-OID-MIB OBJECT-GROUP, MODULE-COMPLIANCE FROM SNMPv2-CONF Integer32, Gauge32, OBJECT-TYPE, MODULE-IDENTITY FROM SNMPv2-SMI TEXTUAL-CONVENTION FROM SNMPv2-TC; optixsonetEqptMgt MODULE-IDENTITY LAST-UPDATED "200605232006Z" -- May 23, 2006 at 20:06 GMT ORGANIZATION "Your organization" CONTACT-INFO "Your contact info" DESCRIPTION "Enter the description for this MIB module." ::= { optixProvisionSonet 3 } -- -- Textual conventions -- IntfType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Enter the description for the IntfType TEXTUAL-CONVENTION converted from type assignment." SYNTAX INTEGER { ds1-asyn-vt1(1), ds3-asyn-sts1(10), ec(12), ds3-tmux-ds1(13), ds3-srv-ds1(17), uas(65), mix(100), invalid(254) } -- -- Node definitions -- -- 1.3.6.1.4.1.2011.2.25.4.20.3.1 optixsonetCardInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixsonetCardInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table describes the equipment unit management interface of Huawei SONET transmit platform " ::= { optixsonetEqptMgt 1 } -- 1.3.6.1.4.1.2011.2.25.4.20.3.1.1 optixsonetCardInfoEntry OBJECT-TYPE SYNTAX OptixsonetCardInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The equipment unit management entry " INDEX { cardIndexSlotId, cardIndexSfpId } ::= { optixsonetCardInfoTable 1 } OptixsonetCardInfoEntry ::= SEQUENCE { cardIndexSlotId Gauge32, cardIndexSfpId Gauge32, cardProvisionType OCTET STRING, cardPhysicalType OCTET STRING, cardInterfaceType IntfType, cardBandwidth Integer32, cardSerialNum OCTET STRING, cardCLEICode OCTET STRING, cardPartNum OCTET STRING, cardDOM OCTET STRING, cardPCBVersion OCTET STRING, cardSWVersion OCTET STRING, cardFPGAVersion OCTET STRING, cardEPLDVersion OCTET STRING, cardBIOSVersion OCTET STRING, cardMAC OCTET STRING, cardPSTState OCTET STRING, cardSSTState OCTET STRING, cardTPSPriority Gauge32, cardSwitchState INTEGER, cardDescription OCTET STRING } -- 1.3.6.1.4.1.2011.2.25.4.20.3.1.1.1 cardIndexSlotId OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Slot number. This will indicate what is the slot of the object." ::= { optixsonetCardInfoEntry 1 } -- 1.3.6.1.4.1.2011.2.25.4.20.3.1.1.2 cardIndexSfpId OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "SFP identifier. This will indicate what is the SFP Slot of the object.For the card unit, I will be zero." ::= { optixsonetCardInfoEntry 2 } -- 1.3.6.1.4.1.2011.2.25.4.20.3.1.1.3 cardProvisionType OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..16)) MAX-ACCESS read-only STATUS current DESCRIPTION "It means the logical unit type provisioned by user." ::= { optixsonetCardInfoEntry 3 } -- 1.3.6.1.4.1.2011.2.25.4.20.3.1.1.4 cardPhysicalType OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "It means the physical unit type inserted in the slot." ::= { optixsonetCardInfoEntry 4 } -- 1.3.6.1.4.1.2011.2.25.4.20.3.1.1.5 cardInterfaceType OBJECT-TYPE SYNTAX IntfType MAX-ACCESS read-only STATUS current DESCRIPTION "The AID unit interface type.This parameter is optional and can be used only for tributary units" ::= { optixsonetCardInfoEntry 5 } -- 1.3.6.1.4.1.2011.2.25.4.20.3.1.1.6 cardBandwidth OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The available bandwidth of the unit when it is provisioned in the slot. It is displayed when the Ethernet unit, the OC-N unit or the tributary unit is provisioned. It is the minimum value of the slot bus bandwidth and bandwidth of the unit." ::= { optixsonetCardInfoEntry 6 } -- 1.3.6.1.4.1.2011.2.25.4.20.3.1.1.7 cardSerialNum OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "The serial number for the equipment. Valid value is a string and is optional." ::= { optixsonetCardInfoEntry 7 } -- 1.3.6.1.4.1.2011.2.25.4.20.3.1.1.8 cardCLEICode OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..16)) MAX-ACCESS read-only STATUS current DESCRIPTION "The CLEI code for the equipment. Valid value is a string and is optional." ::= { optixsonetCardInfoEntry 8 } -- 1.3.6.1.4.1.2011.2.25.4.20.3.1.1.9 cardPartNum OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..20)) MAX-ACCESS read-only STATUS current DESCRIPTION "Part number of the unit. Valid value is a unique 8-digit number for the unit." ::= { optixsonetCardInfoEntry 9 } -- 1.3.6.1.4.1.2011.2.25.4.20.3.1.1.10 cardDOM OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..16)) MAX-ACCESS read-only STATUS current DESCRIPTION "The date when the unit was manufactured and is optional." ::= { optixsonetCardInfoEntry 10 } -- 1.3.6.1.4.1.2011.2.25.4.20.3.1.1.11 cardPCBVersion OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..16)) MAX-ACCESS read-only STATUS current DESCRIPTION "The PCB version for the equipment. Valid value is a string and is optional." ::= { optixsonetCardInfoEntry 11 } -- 1.3.6.1.4.1.2011.2.25.4.20.3.1.1.12 cardSWVersion OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "The software version for the equipment." ::= { optixsonetCardInfoEntry 12 } -- 1.3.6.1.4.1.2011.2.25.4.20.3.1.1.13 cardFPGAVersion OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "The FPGA version for the equipment. Valid value is a string and is optional." ::= { optixsonetCardInfoEntry 13 } -- 1.3.6.1.4.1.2011.2.25.4.20.3.1.1.14 cardEPLDVersion OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..8)) MAX-ACCESS read-only STATUS current DESCRIPTION "The EPLD version for the equipment. Valid value is a string and is optional." ::= { optixsonetCardInfoEntry 14 } -- 1.3.6.1.4.1.2011.2.25.4.20.3.1.1.15 cardBIOSVersion OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "The BIOS version for the equipment. Valid value for is a string and is optional." ::= { optixsonetCardInfoEntry 15 } -- 1.3.6.1.4.1.2011.2.25.4.20.3.1.1.16 cardMAC OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "The MAC address of a common control unit. Valid value is a string like 00-B0-D0-E3-4C-DE and is optional." ::= { optixsonetCardInfoEntry 16 } -- 1.3.6.1.4.1.2011.2.25.4.20.3.1.1.17 cardPSTState OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..16)) MAX-ACCESS read-only STATUS current DESCRIPTION " means the primary state of the entity." ::= { optixsonetCardInfoEntry 17 } -- 1.3.6.1.4.1.2011.2.25.4.20.3.1.1.18 cardSSTState OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION " means the secondary state of the entity." ::= { optixsonetCardInfoEntry 18 } -- 1.3.6.1.4.1.2011.2.25.4.20.3.1.1.19 cardTPSPriority OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The priority of the AID unit if the unit is a working unit of a DSn (TPS) protection group. For any other units, this parameter is not available. This attribute will be used when multi-units fault in a DSn (TPS) protection group.Valid values are list below Value Description 1 The highest priority for the unit in a TPS protection group 2 The secondary priority for the unit in a TPS protection group 3 The third priority for the unit in a TPS protection group 4 The lowest priority for the unit in a TPS protection group " ::= { optixsonetCardInfoEntry 19 } -- 1.3.6.1.4.1.2011.2.25.4.20.3.1.1.20 cardSwitchState OBJECT-TYPE SYNTAX INTEGER { stateDNR(1), stateWTR(2), stateMAN(3), stateAUTOSW(4), stateFRCD(5), stateLOCK(6), stateINVALID(254), stateIDLE(255) } MAX-ACCESS read-only STATUS current DESCRIPTION "The switch state of the AID unit if the unit is a unit of a DSn (TPS) protection group. Switch state of SONET equipment protection Value Description AUTO_SW Automatic switch DNR Do not revert FRCD Forced switch IDLE Idle LOCKOUT Lock to the working unit MAN Manually switch WTR Wait to restore " ::= { optixsonetCardInfoEntry 20 } -- 1.3.6.1.4.1.2011.2.25.4.20.3.1.1.21 cardDescription OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { optixsonetCardInfoEntry 21 } -- 1.3.6.1.4.1.2011.2.25.4.20.3.2 optixsonetEqptMgtConformance OBJECT IDENTIFIER ::= { optixsonetEqptMgt 2 } -- 1.3.6.1.4.1.2011.2.25.4.20.3.2.1 optixsonetEqptMgtGroups OBJECT IDENTIFIER ::= { optixsonetEqptMgtConformance 1 } -- 1.3.6.1.4.1.2011.2.25.4.20.3.2.1.1 currentObjectGroup OBJECT-GROUP OBJECTS { cardIndexSlotId, cardIndexSfpId, cardProvisionType, cardPhysicalType, cardInterfaceType, cardBandwidth, cardSerialNum, cardCLEICode, cardPartNum, cardDOM, cardPCBVersion, cardSWVersion, cardFPGAVersion, cardEPLDVersion, cardBIOSVersion, cardMAC, cardPSTState, cardSSTState, cardTPSPriority, cardSwitchState, cardDescription } STATUS current DESCRIPTION "Enter the description of the created OBJECT-GROUP." ::= { optixsonetEqptMgtGroups 1 } -- 1.3.6.1.4.1.2011.2.25.4.20.3.2.2 optixsonetEqptMgtCompliances OBJECT IDENTIFIER ::= { optixsonetEqptMgtConformance 2 } -- 1.3.6.1.4.1.2011.2.25.4.20.3.2.2.1 basicCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "Enter the description of the created MODULE-COMPLIANCE." MODULE -- this module MANDATORY-GROUPS { currentObjectGroup } ::= { optixsonetEqptMgtCompliances 1 } END -- -- OPTIX-SONET-EQPTMGT-MIB-V2.mib --