OMNI-gx2Dm1000-MIB DEFINITIONS ::= BEGIN IMPORTS Counter FROM RFC1155-SMI IpAddress, TimeTicks FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 sysUpTime, DisplayString FROM RFC1213-MIB TRAP-TYPE FROM RFC-1215 gi, motproxies FROM NLS-BBNIDENT-MIB gx2Dm1000 FROM GX2HFC-MIB trapIdentifier,trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapNETrapLastTrapTimeStamp, trapChangedObjectId, trapChangedValueInteger, trapChangedValueDisplayString FROM NLSBBN-TRAPS-MIB; -- This MIB module uses the extended OBJECT-TYPE macro as -- defined in RFC1212 and the TRAP-TYPE macro as defined -- in RFC 1215. --REVISION "0" Oct 1, 2007 --DESCRIPTION -- Added revision and description comment section -- OMNISTAR DM 1550 Laser Module (Forward Path Transmetter) MIB MODULE -- This MIB module defines information for management of HFC networks -- -- The MIB module assumes that all generic (static) network element -- information is defined in a different module such as the HFC module -- The MIB consists of two groups: -- the device type descriptor subgroup and -- gx2Dm1000 Network Elements subgroup. -- The device type descriptor subgroup is used to define -- parameters specific to gx2Dm1000 device type. -- These parameters are common across all network elements -- from gx2Dm1000 device type. -- -- The gx2Dm1000 Network Elements subgroup is -- a list of gx2Dm1000 type elements in the -- current network topology with nominal -- and current parameter values for the -- individual network elements; the individual -- network elements are identified by -- index from hfcCommonTable. -- That implies what hfcCommonTableIndex and -- gx2Dm1000TableIndex are equal for each individual -- network element. -- This table is an extension of the hfcCommonTable -- for all elements of gx2Dm1000 type. -- -- Both groups are mandatory for management of gx2Dm1000 devices. -- **************************************************************************** -- -- All floating point numbers will be represented by an IEEE 32 Bit number. -- Conversion of this number must be done on the user interface to view the -- actual floating point number. -- Float ::= Counter -- UNSIGNED (32 BITS) -- **************************************************************************** -- gx2Dm1000 Device Descriptor subgroup. -- The device type descriptor subgroup is used to define -- parameters specific to gx2Dm1000 device type. -- These parameters are common across all network elements -- from gx2Dm1000 device type. gx2Dm1000Descriptor OBJECT IDENTIFIER ::= {gx2Dm1000 1} --***************************************************************************** -- gx2Dm1000 Table -- Contains a list of all gx2Dm1000 type devices in -- the network. Each device is characterized with -- current network topology information, with nominal -- and current parameter values for the -- individual network elements; -- -- The individual network elements indentified by -- index from hfcCommonTable. -- That implies what hfcCommonTableIndex and -- gx2Dm1000TableIndex are equal for each individual -- nettwork element. -- This table should be used as an extension of the hfcCommonTable -- for all elements of gx2Dm1000 type. gx2Dm1000AnalogTable OBJECT-TYPE SYNTAX SEQUENCE OF Gx2Dm1000AnalogEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains gx2Dm1000 specific parameters with nominal and current values." ::= { gx2Dm1000 2 } gx2Dm1000AnalogEntry OBJECT-TYPE SYNTAX Gx2Dm1000AnalogEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This list contains the analog parameters and descriptions." INDEX { gx2Dm1000AnalogTableIndex } ::= { gx2Dm1000AnalogTable 1} --************************************************************************* gx2Dm1000DigitalTable OBJECT-TYPE SYNTAX SEQUENCE OF Gx2Dm1000DigitalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains gx2Dm1000m specific parameters with nominal and current values." ::= { gx2Dm1000 3 } gx2Dm1000DigitalEntry OBJECT-TYPE SYNTAX Gx2Dm1000DigitalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This list contains digital parameters and descriptions." INDEX { gx2Dm1000DigitalTableIndex } ::= { gx2Dm1000DigitalTable 2} --************************************************************************* gx2Dm1000StatusTable OBJECT-TYPE SYNTAX SEQUENCE OF Gx2Dm1000StatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains gx2Dm1000 specific parameters with nominal and current values." ::= { gx2Dm1000 4 } gx2Dm1000StatusEntry OBJECT-TYPE SYNTAX Gx2Dm1000StatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This list contains Status parameters and descriptions." INDEX { gx2Dm1000StatusTableIndex } ::= { gx2Dm1000StatusTable 3} --************************************************************************* gx2Dm1000FactoryTable OBJECT-TYPE SYNTAX SEQUENCE OF Gx2Dm1000FactoryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains gx2Dm1000 specific parameters with nominal and current values." ::= { gx2Dm1000 5 } gx2Dm1000FactoryEntry OBJECT-TYPE SYNTAX Gx2Dm1000FactoryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This list contains Factory parameters and descriptions." INDEX { gx2Dm1000FactoryTableIndex } ::= { gx2Dm1000FactoryTable 4} --************************************************************************* Gx2Dm1000AnalogEntry ::= SEQUENCE { gx2Dm1000AnalogTableIndex INTEGER, -- Analog Parameters dm1000labelOffsetNomMonitor DisplayString (SIZE (0..80)), dm1000uomOffsetNomMonitor DisplayString (SIZE (0..80)), dm1000majorHighOffsetNomMonitor Float, dm1000majorLowOffsetNomMonitor Float, dm1000minorHighOffsetNomMonitor Float, dm1000minorLowOffsetNomMonitor Float, dm1000currentValueOffsetNomMonitor Float, dm1000stateFlagOffsetNomMonitor INTEGER, dm1000minValueOffsetNomMonitor Float, dm1000maxValueOffsetNomMonitor Float, dm1000alarmStateOffsetNomMonitor INTEGER, dm1000labelOffsetNomCnt DisplayString (SIZE (0..80)), dm1000uomOffsetNomCnt DisplayString (SIZE (0..80)), dm1000majorHighOffsetNomCnt Float, dm1000majorLowOffsetNomCnt Float, dm1000minorHighOffsetNomCnt Float, dm1000minorLowOffsetNomCnt Float, dm1000currentValueOffsetNomCnt Float, dm1000stateFlagOffsetNomCnt INTEGER, dm1000minValueOffsetNomCnt Float, dm1000maxValueOffsetNomCnt Float, dm1000alarmStateOffsetNomCnt INTEGER, dm1000labelAttenSetting DisplayString (SIZE (0..80)), dm1000uomAttenSetting DisplayString (SIZE (0..80)), dm1000majorHighAttenSetting Float, dm1000majorLowAttenSetting Float, dm1000minorHighAttenSetting Float, dm1000minorLowAttenSetting Float, dm1000currentValueAttenSetting Float, dm1000stateFlagAttenSetting INTEGER, dm1000minValueAttenSetting Float, dm1000maxValueAttenSetting Float, dm1000alarmStateAttenSetting INTEGER, dm1000labelLaserPower DisplayString (SIZE (0..80)), dm1000uomLaserPower DisplayString (SIZE (0..80)), dm1000majorHighLaserPower Float, dm1000majorLowLaserPower Float, dm1000minorHighLaserPower Float, dm1000minorLowLaserPower Float, dm1000currentValueLaserPower Float, dm1000stateFlagLaserPower INTEGER, dm1000minValueLaserPower Float, dm1000maxValueLaserPower Float, dm1000alarmStateLaserPower INTEGER, dm1000labelLaserTemp DisplayString (SIZE (0..80)), dm1000uomLaserTemp DisplayString (SIZE (0..80)), dm1000majorHighLaserTemp Float, dm1000majorLowLaserTemp Float, dm1000minorHighLaserTemp Float, dm1000minorLowLaserTemp Float, dm1000currentValueLaserTemp Float, dm1000stateFlagLaserTemp INTEGER, dm1000minValueLaserTemp Float, dm1000maxValueLaserTemp Float, dm1000alarmStateLaserTemp INTEGER, dm1000labelLaserCurrent DisplayString (SIZE (0..80)), dm1000uomLaserCurrent DisplayString (SIZE (0..80)), dm1000majorHighLaserCurrent Float, dm1000majorLowLaserCurrent Float, dm1000minorHighLaserCurrent Float, dm1000minorLowLaserCurrent Float, dm1000currentValueLaserCurrent Float, dm1000stateFlagLaserCurrent INTEGER, dm1000minValueLaserCurrent Float, dm1000maxValueLaserCurrent Float, dm1000alarmStateLaserCurrent INTEGER, dm1000labelTecCurrent DisplayString (SIZE (0..80)), dm1000uomTecCurrent DisplayString (SIZE (0..80)), dm1000majorHighTecCurrent Float, dm1000majorLowTecCurrent Float, dm1000minorHighTecCurrent Float, dm1000minorLowTecCurrent Float, dm1000currentValueTecCurrent Float, dm1000stateFlagTecCurrent INTEGER, dm1000minValueTecCurrent Float, dm1000maxValueTecCurrent Float, dm1000alarmStateTecCurrent INTEGER, dm1000labelModTemp DisplayString (SIZE (0..80)), dm1000uomModTemp DisplayString (SIZE (0..80)), dm1000majorHighModTemp Float, dm1000majorLowModTemp Float, dm1000minorHighModTemp Float, dm1000minorLowModTemp Float, dm1000currentValueModTemp Float, dm1000stateFlagModTemp INTEGER, dm1000minValueModTemp Float, dm1000maxValueModTemp Float, dm1000alarmStateModTemp INTEGER, dm1000labelFanCurrent DisplayString (SIZE (0..80)), dm1000uomFanCurrent DisplayString (SIZE (0..80)), dm1000majorHighFanCurrent Float, dm1000majorLowFanCurrent Float, dm1000minorHighFanCurrent Float, dm1000minorLowFanCurrent Float, dm1000currentValueFanCurrent Float, dm1000stateFlagFanCurrent INTEGER, dm1000minValueFanCurrent Float, dm1000maxValueFanCurrent Float, dm1000alarmStateFanCurrent INTEGER } -- **************** Digital Parameters *********************** Gx2Dm1000DigitalEntry ::= SEQUENCE { gx2Dm1000DigitalTableIndex INTEGER, dm1000labelRfInput DisplayString (SIZE (0..80)), dm1000enumRfInput DisplayString (SIZE (0..80)), dm1000valueRfInput INTEGER, dm1000stateflagRfInput INTEGER, dm1000labelOptOutput DisplayString (SIZE (0..80)), dm1000enumOptOutput DisplayString (SIZE (0..80)), dm1000valueOptOutput INTEGER, dm1000stateflagOptOutput INTEGER, dm1000labelSbsControl DisplayString (SIZE (0..80)), dm1000enumSbsControl DisplayString (SIZE (0..80)), dm1000valueSbsControl INTEGER, dm1000stateflagSbsControl INTEGER, dm1000labelLaserMode DisplayString (SIZE (0..80)), dm1000enumLaserMode DisplayString (SIZE (0..80)), dm1000valueLaserMode INTEGER, dm1000stateflagLaserMode INTEGER, dm1000labelFactoryDefault DisplayString (SIZE (0..80)), dm1000enumFactoryDefault DisplayString (SIZE (0..80)), dm1000valueFactoryDefault INTEGER, dm1000stateflagFactoryDefault INTEGER } -- **************** Status Parameters ************************************ Gx2Dm1000StatusEntry ::= SEQUENCE { gx2Dm1000StatusTableIndex INTEGER, dm1000labelBoot DisplayString (SIZE (0..80)), dm1000valueBoot INTEGER, dm1000stateflagBoot INTEGER, dm1000labelFlash DisplayString (SIZE (0..80)), dm1000valueFlash INTEGER, dm1000stateflagFlash INTEGER, dm1000labelFactoryDataCRC DisplayString (SIZE (0..80)), dm1000valueFactoryDataCRC INTEGER, dm1000stateflagFactoryDataCRC INTEGER, dm1000labelLaserDataCRC DisplayString (SIZE (0..80)), dm1000valueLaserDataCRC INTEGER, dm1000stateflagLaserDataCRC INTEGER, dm1000labelAlarmDataCrc DisplayString (SIZE (0..80)), dm1000valueAlarmDataCrc INTEGER, dm1000stateflagAlarmDataCrc INTEGER, dm1000labelRFInputStatus DisplayString (SIZE (0..80)), dm1000valueRFInputStatus INTEGER, dm1000stateflagRFInputStatus INTEGER } -- **************** Factory Parameters ************************************* Gx2Dm1000FactoryEntry ::= SEQUENCE { gx2Dm1000FactoryTableIndex INTEGER, dm1000bootControlByte INTEGER, dm1000bootStatusByte INTEGER, dm1000bank1CRC INTEGER, dm1000bank2CRC INTEGER, dm1000prgEEPROMByte INTEGER, dm1000factoryCRC INTEGER, dm1000calculateCRC INTEGER, dm1000hourMeter INTEGER, dm1000flashPrgCntA INTEGER, dm1000flashPrgCntB INTEGER, dm1000flashBankARev DisplayString (SIZE (0..80)), dm1000flashBankBRev DisplayString (SIZE (0..80)) } -- ************** Analog Parameters **************************** gx2Dm1000AnalogTableIndex OBJECT-TYPE SYNTAX INTEGER (1..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element." ::= { gx2Dm1000AnalogEntry 1} -- New Parameter dm1000labelOffsetNomMonitor OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Offset Monitor Analog parameter." ::= { gx2Dm1000AnalogEntry 2} dm1000uomOffsetNomMonitor OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Offset Monitor Analog parameter." ::= { gx2Dm1000AnalogEntry 3} dm1000majorHighOffsetNomMonitor OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Offset Monitor Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2Dm1000AnalogEntry 4} dm1000majorLowOffsetNomMonitor OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Offset Monitor Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2Dm1000AnalogEntry 5} dm1000minorHighOffsetNomMonitor OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the Offset Monitor Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2Dm1000AnalogEntry 6} dm1000minorLowOffsetNomMonitor OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the Offset Monitor Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2Dm1000AnalogEntry 7} dm1000currentValueOffsetNomMonitor OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Offset Monitor Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Dm1000AnalogEntry 8} dm1000stateFlagOffsetNomMonitor OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Offset Monitor Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Dm1000AnalogEntry 9} dm1000minValueOffsetNomMonitor OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the Offset Monitor Power Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Dm1000AnalogEntry 10} dm1000maxValueOffsetNomMonitor OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the Offset Monitor Power Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Dm1000AnalogEntry 11} dm1000alarmStateOffsetNomMonitor OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Offset Monitor Power Analog parameter." ::= { gx2Dm1000AnalogEntry 12} -- New Parameter dm1000labelOffsetNomCnt OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Offset Control Analog parameter." ::= { gx2Dm1000AnalogEntry 13} dm1000uomOffsetNomCnt OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Offset Control Analog parameter.." ::= { gx2Dm1000AnalogEntry 14} dm1000majorHighOffsetNomCnt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS obsolete DESCRIPTION "The value of this object provides the Major High alarm value of the Offset Control Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2Dm1000AnalogEntry 15} dm1000majorLowOffsetNomCnt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS obsolete DESCRIPTION "The value of this object provides the Major Low alarm value of the Offset Control Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2Dm1000AnalogEntry 16} dm1000minorHighOffsetNomCnt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS obsolete DESCRIPTION "The value of this object provides the Minor High alarm value of the Offset Control Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2Dm1000AnalogEntry 17} dm1000minorLowOffsetNomCnt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS obsolete DESCRIPTION "The value of this object provides the Minor Low alarm value of the Offset Control Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2Dm1000AnalogEntry 18} dm1000currentValueOffsetNomCnt OBJECT-TYPE SYNTAX Float ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Offset Control Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Dm1000AnalogEntry 19} dm1000stateFlagOffsetNomCnt OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Offset Control Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Dm1000AnalogEntry 20} dm1000minValueOffsetNomCnt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the Offset Control Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Dm1000AnalogEntry 21} dm1000maxValueOffsetNomCnt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the Offset Control Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Dm1000AnalogEntry 22} dm1000alarmStateOffsetNomCnt OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS obsolete DESCRIPTION "The value of this object provides the curent alarm state of the Offset Control Analog parameter." ::= { gx2Dm1000AnalogEntry 23} -- New Parameter dm1000labelAttenSetting OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Attenuator Setting Current Analog parameter." ::= { gx2Dm1000AnalogEntry 24} dm1000uomAttenSetting OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Attenuator Setting Analog parameter." ::= { gx2Dm1000AnalogEntry 25} dm1000majorHighAttenSetting OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS obsolete DESCRIPTION "The value of this object provides the Major High alarm value of the Attenuator Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2Dm1000AnalogEntry 26} dm1000majorLowAttenSetting OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS obsolete DESCRIPTION "The value of this object provides the Major Low alarm value of the Attenuator Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2Dm1000AnalogEntry 27} dm1000minorHighAttenSetting OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS obsolete DESCRIPTION "The value of this object provides the Minor High alarm value of the Attenuator Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2Dm1000AnalogEntry 28} dm1000minorLowAttenSetting OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS obsolete DESCRIPTION "The value of this object provides the Minor Low alarm value of the Attenuator Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2Dm1000AnalogEntry 29} dm1000currentValueAttenSetting OBJECT-TYPE SYNTAX Float ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Attenuator Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Dm1000AnalogEntry 30} dm1000stateFlagAttenSetting OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Attenuator Setting Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Dm1000AnalogEntry 31} dm1000minValueAttenSetting OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the Attenuator Setting Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Dm1000AnalogEntry 32} dm1000maxValueAttenSetting OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the Attenuator Setting Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Dm1000AnalogEntry 33} dm1000alarmStateAttenSetting OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Attenuator Setting Analog parameter." ::= { gx2Dm1000AnalogEntry 34} -- New Parameter dm1000labelLaserPower OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Laser Optical Power Analog parameter." ::= { gx2Dm1000AnalogEntry 35} dm1000uomLaserPower OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Laser Optical Power Analog parameter." ::= { gx2Dm1000AnalogEntry 36} dm1000majorHighLaserPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Laser Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2Dm1000AnalogEntry 37} dm1000majorLowLaserPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Laser Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2Dm1000AnalogEntry 38} dm1000minorHighLaserPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS obsolete DESCRIPTION "The value of this object provides the Minor High alarm value of the Laser Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2Dm1000AnalogEntry 39} dm1000minorLowLaserPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS obsolete DESCRIPTION "The value of this object provides the Minor Low alarm value of the Laser Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2Dm1000AnalogEntry 40} dm1000currentValueLaserPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Laser Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Dm1000AnalogEntry 41} dm1000stateFlagLaserPower OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Laser Optical Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Dm1000AnalogEntry 42} dm1000minValueLaserPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the Laser Optical Power Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Dm1000AnalogEntry 43} dm1000maxValueLaserPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the Laser Optical Power Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Dm1000AnalogEntry 44} dm1000alarmStateLaserPower OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Laser Optical Power Analog parameter." ::= { gx2Dm1000AnalogEntry 45} -- New Parameter dm1000labelLaserTemp OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Laser Temperature Analog parameter." ::= { gx2Dm1000AnalogEntry 46} dm1000uomLaserTemp OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Laser Temperature Analog parameter.." ::= { gx2Dm1000AnalogEntry 47} dm1000majorHighLaserTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2Dm1000AnalogEntry 48} dm1000majorLowLaserTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2Dm1000AnalogEntry 49} dm1000minorHighLaserTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS obsolete DESCRIPTION "The value of this object provides the Minor High alarm value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2Dm1000AnalogEntry 50} dm1000minorLowLaserTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS obsolete DESCRIPTION "The value of this object provides the Minor Low alarm value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2Dm1000AnalogEntry 51} dm1000currentValueLaserTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Dm1000AnalogEntry 52} dm1000stateFlagLaserTemp OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Laser Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Dm1000AnalogEntry 53} dm1000minValueLaserTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the Laser Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Dm1000AnalogEntry 54} dm1000maxValueLaserTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the Laser Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Dm1000AnalogEntry 55} dm1000alarmStateLaserTemp OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Laser Temperature Analog parameter." ::= { gx2Dm1000AnalogEntry 56} -- New Parameter dm1000labelLaserCurrent OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Laser Bias Current Analog parameter." ::= { gx2Dm1000AnalogEntry 57} dm1000uomLaserCurrent OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Laser Bias Current Analog parameter." ::= { gx2Dm1000AnalogEntry 58} dm1000majorHighLaserCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Laser Bias Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2Dm1000AnalogEntry 59} dm1000majorLowLaserCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Laser Bias Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2Dm1000AnalogEntry 60} dm1000minorHighLaserCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS obsolete DESCRIPTION "The value of this object provides the Minor High alarm value of the Laser Bias Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2Dm1000AnalogEntry 61} dm1000minorLowLaserCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS obsolete DESCRIPTION "The value of this object provides the Minor Low alarm value of the Laser Bias Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2Dm1000AnalogEntry 62} dm1000currentValueLaserCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Laser Bias Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Dm1000AnalogEntry 63} dm1000stateFlagLaserCurrent OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Laser Bias Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Dm1000AnalogEntry 64} dm1000minValueLaserCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the Laser Bias Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Dm1000AnalogEntry 65} dm1000maxValueLaserCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the Laser Bias Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Dm1000AnalogEntry 66} dm1000alarmStateLaserCurrent OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Laser Bias Current Analog parameter." ::= { gx2Dm1000AnalogEntry 67} -- New Parameter dm1000labelTecCurrent OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the TEC Current Analog parameter." ::= { gx2Dm1000AnalogEntry 68} dm1000uomTecCurrent OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the TEC Current Analog parameter." ::= { gx2Dm1000AnalogEntry 69} dm1000majorHighTecCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2Dm1000AnalogEntry 70} dm1000majorLowTecCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2Dm1000AnalogEntry 71} dm1000minorHighTecCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS obsolete DESCRIPTION "The value of this object provides the Minor High alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2Dm1000AnalogEntry 72} dm1000minorLowTecCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS obsolete DESCRIPTION "The value of this object provides the Minor Low alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2Dm1000AnalogEntry 73} dm1000currentValueTecCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Dm1000AnalogEntry 74} dm1000stateFlagTecCurrent OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the TEC Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Dm1000AnalogEntry 75} dm1000minValueTecCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the TEC Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Dm1000AnalogEntry 76} dm1000maxValueTecCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the TEC Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Dm1000AnalogEntry 77} dm1000alarmStateTecCurrent OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the TEC Current Analog parameter." ::= { gx2Dm1000AnalogEntry 78} -- New Parameter dm1000labelModTemp OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Module Temperature Analog parameter." ::= { gx2Dm1000AnalogEntry 79} dm1000uomModTemp OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Module Temperature Analog parameter." ::= { gx2Dm1000AnalogEntry 80} dm1000majorHighModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2Dm1000AnalogEntry 81} dm1000majorLowModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2Dm1000AnalogEntry 82} dm1000minorHighModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2Dm1000AnalogEntry 83} dm1000minorLowModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2Dm1000AnalogEntry 84} dm1000currentValueModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Dm1000AnalogEntry 85} dm1000stateFlagModTemp OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Module Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Dm1000AnalogEntry 86} dm1000minValueModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Dm1000AnalogEntry 87} dm1000maxValueModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Dm1000AnalogEntry 88} dm1000alarmStateModTemp OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Module Temperature Analog parameter." ::= { gx2Dm1000AnalogEntry 89} -- New Parameter dm1000labelFanCurrent OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Fan Current Analog parameter." ::= { gx2Dm1000AnalogEntry 90} dm1000uomFanCurrent OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Fan Current Analog parameter." ::= { gx2Dm1000AnalogEntry 91} dm1000majorHighFanCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2Dm1000AnalogEntry 92} dm1000majorLowFanCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2Dm1000AnalogEntry 93} dm1000minorHighFanCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS obsolete DESCRIPTION "The value of this object provides the Minor High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2Dm1000AnalogEntry 94} dm1000minorLowFanCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS obsolete DESCRIPTION "The value of this object provides the Minor Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2Dm1000AnalogEntry 95} dm1000currentValueFanCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Dm1000AnalogEntry 96} dm1000stateFlagFanCurrent OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Fan Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Dm1000AnalogEntry 97} dm1000minValueFanCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the Fan Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Dm1000AnalogEntry 98} dm1000maxValueFanCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the Fan Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Dm1000AnalogEntry 99} dm1000alarmStateFanCurrent OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Fan Current Analog parameter." ::= { gx2Dm1000AnalogEntry 100} -- ************************ Digital parameters ********************************** gx2Dm1000DigitalTableIndex OBJECT-TYPE SYNTAX INTEGER (1..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element." ::= { gx2Dm1000DigitalEntry 1} -- New parameter dm1000labelRfInput OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the RF Input Control Digital parameter." ::= { gx2Dm1000DigitalEntry 2} dm1000enumRfInput OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2Dm1000DigitalEntry 3} dm1000valueRfInput OBJECT-TYPE SYNTAX INTEGER { off(1), on(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter." ::= { gx2Dm1000DigitalEntry 4} dm1000stateflagRfInput OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the RF Input Control Digital parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Dm1000DigitalEntry 5} -- New parameter dm1000labelOptOutput OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Optical Output Control Digital parameter." ::= { gx2Dm1000DigitalEntry 6} dm1000enumOptOutput OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2Dm1000DigitalEntry 7} dm1000valueOptOutput OBJECT-TYPE SYNTAX INTEGER { off(1), on(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter." ::= { gx2Dm1000DigitalEntry 8} dm1000stateflagOptOutput OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Dm1000DigitalEntry 9} -- New parameter dm1000labelSbsControl OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the SBS Control Digital parameter." ::= { gx2Dm1000DigitalEntry 10} dm1000enumSbsControl OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2Dm1000DigitalEntry 11} dm1000valueSbsControl OBJECT-TYPE SYNTAX INTEGER { off(1), on(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter." ::= { gx2Dm1000DigitalEntry 12} dm1000stateflagSbsControl OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Dm1000DigitalEntry 13} -- New parameter dm1000labelLaserMode OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Laser Mode Digital parameter." ::= { gx2Dm1000DigitalEntry 14} dm1000enumLaserMode OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2Dm1000DigitalEntry 15} dm1000valueLaserMode OBJECT-TYPE SYNTAX INTEGER { preset(1), set(2), setEquate(3), manual(4), manualEquate(5) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter." ::= { gx2Dm1000DigitalEntry 16} dm1000stateflagLaserMode OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Dm1000DigitalEntry 17} -- New parameter dm1000labelFactoryDefault OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Factory Default Digital parameter." ::= { gx2Dm1000DigitalEntry 18} dm1000enumFactoryDefault OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.." ::= { gx2Dm1000DigitalEntry 19} dm1000valueFactoryDefault OBJECT-TYPE SYNTAX INTEGER { off(1), on(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter. Return value is meaningless" ::= { gx2Dm1000DigitalEntry 20} dm1000stateflagFactoryDefault OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Dm1000DigitalEntry 21} -- *********** STATUS ***************** gx2Dm1000StatusTableIndex OBJECT-TYPE SYNTAX INTEGER (1..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element." ::= { gx2Dm1000StatusEntry 1} --New Parameter dm1000labelBoot OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Boot Status Status parameter." ::= { gx2Dm1000StatusEntry 2} dm1000valueBoot OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2Dm1000StatusEntry 3} dm1000stateflagBoot OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Dm1000StatusEntry 4} --New Parameter dm1000labelFlash OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Flash Status Status parameter." ::= { gx2Dm1000StatusEntry 5} dm1000valueFlash OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2Dm1000StatusEntry 6} dm1000stateflagFlash OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Dm1000StatusEntry 7} --New Parameter dm1000labelFactoryDataCRC OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Factory Data CRC Status parameter." ::= { gx2Dm1000StatusEntry 8} dm1000valueFactoryDataCRC OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2Dm1000StatusEntry 9} dm1000stateflagFactoryDataCRC OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Dm1000StatusEntry 10} --New Parameter dm1000labelLaserDataCRC OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Laser Data CRC Status parameter." ::= { gx2Dm1000StatusEntry 11} dm1000valueLaserDataCRC OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2Dm1000StatusEntry 12} dm1000stateflagLaserDataCRC OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Dm1000StatusEntry 13} --New Parameter dm1000labelAlarmDataCrc OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Alarm Data Crc parameter." ::= { gx2Dm1000StatusEntry 14} dm1000valueAlarmDataCrc OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2Dm1000StatusEntry 15} dm1000stateflagAlarmDataCrc OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Dm1000StatusEntry 16} --New Parameter dm1000labelRFInputStatus OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Alarm Data Crc parameter." ::= { gx2Dm1000StatusEntry 17} dm1000valueRFInputStatus OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2Dm1000StatusEntry 18} dm1000stateflagRFInputStatus OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Dm1000StatusEntry 19} -- ************ FACTORY DATA **************** gx2Dm1000FactoryTableIndex OBJECT-TYPE SYNTAX INTEGER (1..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element." ::= { gx2Dm1000FactoryEntry 1} dm1000bootControlByte OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object indicates which bank the firmware is currently being boot from." ::= { gx2Dm1000FactoryEntry 2} dm1000bootStatusByte OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the status of the last boot. Bit 2 = Bank 0/1 Active (0 = Bank 0, 1 = Bank 1), Bit 1 = Bank 1 Fail and Bit 0 = Bank 0 Fail (0 = Pass, 1 = Fail)" ::= { gx2Dm1000FactoryEntry 3} dm1000bank1CRC OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the CRC code of bank 0. The display formate for the data is Hex." ::= { gx2Dm1000FactoryEntry 4} dm1000bank2CRC OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the CRC code of bank 1.The display formate for the data is Hex." ::= { gx2Dm1000FactoryEntry 5} dm1000prgEEPROMByte OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates if the EEPROM has been programmed" ::= { gx2Dm1000FactoryEntry 6} dm1000factoryCRC OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the CRC code for the Factory data." ::= { gx2Dm1000FactoryEntry 7} dm1000calculateCRC OBJECT-TYPE SYNTAX INTEGER { factory(1), na(2), alarm(3) } ACCESS read-only STATUS obsolete DESCRIPTION "This object indicates which of the Enums will have the CRC calculated." ::= { gx2Dm1000FactoryEntry 8} dm1000hourMeter OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the hour meter reading of the module." ::= { gx2Dm1000FactoryEntry 9} dm1000flashPrgCntA OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the number of times Bank 1 flash has been programmed." ::= { gx2Dm1000FactoryEntry 10} dm1000flashPrgCntB OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the number of times Bank 1 flash has been programmed." ::= { gx2Dm1000FactoryEntry 11} dm1000flashBankARev OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the revision of flash bank 0. The rev is 2 characters." ::= { gx2Dm1000FactoryEntry 12} dm1000flashBankBRev OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the revision of flash bank 1. The rev is 2 characters." ::= { gx2Dm1000FactoryEntry 13} -- **************************************************************** -- -- TRAP DEFINITIONS -- -- -- Every trap generated by an HFC agents will include first 9 identical -- fields. If particular variable is not supported in -- particular TRAP-TYPE then default value will be returned. -- -- DESCRIPTION will include explanation of use of generic -- variables (trapAdditionalInfo******.) If no -- DESCRIPTION is given then generic variables will contain -- default values. -- -- ***************************************************************** --*************************************************************************** -- ***********!!! THE TRAP SECTION HAS NOT BEEN COMPLETED YET !!! *********** --*************************************************************************** -- ************************************************************************** -- DM1000 Module traps -- ************************************************************************** trapDM1000ConfigChangeInteger TRAP-TYPE ENTERPRISE gx2Dm1000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'" ::= 1 trapDM1000ConfigChangeDisplayString TRAP-TYPE ENTERPRISE gx2Dm1000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueDisplayString, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'" ::= 2 trapDM1000fanCurrentAlarm TRAP-TYPE ENTERPRISE gx2Dm1000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Fan Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 3 trapDM1000ModuleTempAlarm TRAP-TYPE ENTERPRISE gx2Dm1000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Module Temperature parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 4 trapDM1000omiOffsetAlarm TRAP-TYPE ENTERPRISE gx2Dm1000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the OMI Offset goes out of range." ::= 5 trapDM1000tecCurrentAlarm TRAP-TYPE ENTERPRISE gx2Dm1000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the TEC Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 6 trapDM1000LaserCurrentAlarm TRAP-TYPE ENTERPRISE gx2Dm1000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Laser Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 7 trapDM1000LaserTempAlarm TRAP-TYPE ENTERPRISE gx2Dm1000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Laser Temp parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 8 trapDM1000LaserPowerAlarm TRAP-TYPE ENTERPRISE gx2Dm1000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Laser Power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 9 trapDM1000FlashAlarm TRAP-TYPE ENTERPRISE gx2Dm1000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Laser Modules detects an error during Flash memory operations." ::= 10 trapDM1000BankBootAlarm TRAP-TYPE ENTERPRISE gx2Dm1000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Laser Modules detects an error while booting from bank 0 or bank 1." ::= 11 trapDM1000AlarmDataCRCAlarm TRAP-TYPE ENTERPRISE gx2Dm1000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Alarm Data CRC is incorrect." ::= 12 trapDM1000FactoryDataCRCAlarm TRAP-TYPE ENTERPRISE gx2Dm1000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Factory Data CRC is incorrect." ::= 13 trapDM1000CalDataCRCAlarm TRAP-TYPE ENTERPRISE gx2Dm1000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Cal Data CRC is incorrect." ::= 14 trapDM1000ResetFacDefault TRAP-TYPE ENTERPRISE gx2Dm1000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the DM1000 resets to factory defaults" ::= 15 trapDM1000UserRFOffAlarm TRAP-TYPE ENTERPRISE gx2Dm1000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the the User RF is turned off." ::= 16 trapDM1000UserOpticalOffAlarm TRAP-TYPE ENTERPRISE gx2Dm1000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the User Optical Power is turned off." ::= 17 trapDM1000UserSBSOffAlarm TRAP-TYPE ENTERPRISE gx2Dm1000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the User SBS is turned off." ::= 18 trapDM1000RFInputAlarm TRAP-TYPE ENTERPRISE gx2Dm1000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Laser Modules RF input parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 19 trapDM1000RFOverloadAlarm TRAP-TYPE ENTERPRISE gx2Dm1000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Laser Modules RF overload parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 20 END