Nortel-MsCarrier-MscPassport-VnetEtsiQsigMIB DEFINITIONS ::= BEGIN IMPORTS OBJECT-TYPE FROM RFC-1212 mscPassportMIBs FROM Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB DisplayString, StorageType, RowStatus, Unsigned32 FROM Nortel-MsCarrier-MscPassport-StandardTextualConventionsMIB NonReplicated, Link FROM Nortel-MsCarrier-MscPassport-TextualConventionsMIB mscSigChan, mscSigChanIndex FROM Nortel-MsCarrier-MscPassport-VoiceNetworkingMIB; -- LAST-UPDATED "9909010000Z" -- ORGANIZATION "Nortel Networks" -- CONTACT-INFO " -- Nortel Carrier Data Network Management -- -- Postal: P.O. Box 3511, Station C -- Ottawa, Ontario -- Canada K1Y 4H7 -- -- via the WEB: http://www.nortelnetworks.com -- select 'Contact Us' from the menu -- -- via phone: 1-800-4NORTEL" -- DESCRIPTION -- "The module describing the Nortel MsCarrier MscPassport -- VnetEtsiQsig Enterprise MIB." vnetEtsiQsigMIB OBJECT IDENTIFIER ::= { mscPassportMIBs 110 } -- SigChan/n EtsiQsig -- The EtsiQsig component defines the operational characteristics of -- the signalling channel's connection to the external equipment. mscSigChanEQsig OBJECT IDENTIFIER ::= { mscSigChan 2 } mscSigChanEQsigRowStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF MscSigChanEQsigRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This entry controls the addition and deletion of mscSigChanEQsig components." ::= { mscSigChanEQsig 1 } mscSigChanEQsigRowStatusEntry OBJECT-TYPE SYNTAX MscSigChanEQsigRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A single entry in the table represents a single mscSigChanEQsig component." INDEX { mscSigChanIndex, mscSigChanEQsigIndex } ::= { mscSigChanEQsigRowStatusTable 1 } MscSigChanEQsigRowStatusEntry ::= SEQUENCE { mscSigChanEQsigRowStatus RowStatus, mscSigChanEQsigComponentName DisplayString, mscSigChanEQsigStorageType StorageType, mscSigChanEQsigIndex NonReplicated } mscSigChanEQsigRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-write STATUS mandatory DESCRIPTION "This variable is used as the basis for SNMP naming of mscSigChanEQsig components. These components can be added and deleted." ::= { mscSigChanEQsigRowStatusEntry 1 } mscSigChanEQsigComponentName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This variable provides the component's string name for use with the ASCII Console Interface" ::= { mscSigChanEQsigRowStatusEntry 2 } mscSigChanEQsigStorageType OBJECT-TYPE SYNTAX StorageType ACCESS read-only STATUS mandatory DESCRIPTION "This variable represents the storage type value for the mscSigChanEQsig tables." ::= { mscSigChanEQsigRowStatusEntry 4 } mscSigChanEQsigIndex OBJECT-TYPE SYNTAX NonReplicated ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable represents the index for the mscSigChanEQsig tables." ::= { mscSigChanEQsigRowStatusEntry 10 } mscSigChanEQsigL2Table OBJECT-TYPE SYNTAX SEQUENCE OF MscSigChanEQsigL2Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "This group specifies the provisionable layer 2 attributes of the Q.931 ITU-T protocol." ::= { mscSigChanEQsig 11 } mscSigChanEQsigL2Entry OBJECT-TYPE SYNTAX MscSigChanEQsigL2Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscSigChanEQsigL2Table." INDEX { mscSigChanIndex, mscSigChanEQsigIndex } ::= { mscSigChanEQsigL2Table 1 } MscSigChanEQsigL2Entry ::= SEQUENCE { mscSigChanEQsigT23 Unsigned32, mscSigChanEQsigT200 Unsigned32, mscSigChanEQsigN200 Unsigned32, mscSigChanEQsigT203 Unsigned32, mscSigChanEQsigCircuitSwitchedK Unsigned32 } mscSigChanEQsigT23 OBJECT-TYPE SYNTAX Unsigned32 (1..15) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the layer 2 enable request timer." DEFVAL { 10 } ::= { mscSigChanEQsigL2Entry 1 } mscSigChanEQsigT200 OBJECT-TYPE SYNTAX Unsigned32 (1..20) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the maximum time between a layer 2 frame and its acknowledgment." DEFVAL { 1 } ::= { mscSigChanEQsigL2Entry 2 } mscSigChanEQsigN200 OBJECT-TYPE SYNTAX Unsigned32 (1..8) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the maximum number of re-transmissions of a layer 2 frame." DEFVAL { 3 } ::= { mscSigChanEQsigL2Entry 3 } mscSigChanEQsigT203 OBJECT-TYPE SYNTAX Unsigned32 (2..40) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the maximum time for which layer 2 frames may be absent. Expiry triggers a check on whether the far end is alive." DEFVAL { 10 } ::= { mscSigChanEQsigL2Entry 4 } mscSigChanEQsigCircuitSwitchedK OBJECT-TYPE SYNTAX Unsigned32 (1..127) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the maximum number of sequentially numbered I frames (that is, window size (k)) that may be unacknowledged at any given time for a SAP supporting primary rate (64kbit/sec) signalling." DEFVAL { 7 } ::= { mscSigChanEQsigL2Entry 6 } mscSigChanEQsigL3Table OBJECT-TYPE SYNTAX SEQUENCE OF MscSigChanEQsigL3Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "This group represents the provisionable Layer 3 timer attributes of the ETSI Qsig protocol." ::= { mscSigChanEQsig 12 } mscSigChanEQsigL3Entry OBJECT-TYPE SYNTAX MscSigChanEQsigL3Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscSigChanEQsigL3Table." INDEX { mscSigChanIndex, mscSigChanEQsigIndex } ::= { mscSigChanEQsigL3Table 1 } MscSigChanEQsigL3Entry ::= SEQUENCE { mscSigChanEQsigT309 Unsigned32, mscSigChanEQsigT310 Unsigned32 } mscSigChanEQsigT309 OBJECT-TYPE SYNTAX Unsigned32 (15..120) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the data link failure timer; used to ride out temporary failures." DEFVAL { 90 } ::= { mscSigChanEQsigL3Entry 3 } mscSigChanEQsigT310 OBJECT-TYPE SYNTAX Unsigned32 (10..120) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the call proceeding state timer." DEFVAL { 30 } ::= { mscSigChanEQsigL3Entry 4 } mscSigChanEQsigProvTable OBJECT-TYPE SYNTAX SEQUENCE OF MscSigChanEQsigProvEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This group defines the general options of the D-channel signalling link." ::= { mscSigChanEQsig 13 } mscSigChanEQsigProvEntry OBJECT-TYPE SYNTAX MscSigChanEQsigProvEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscSigChanEQsigProvTable." INDEX { mscSigChanIndex, mscSigChanEQsigIndex } ::= { mscSigChanEQsigProvTable 1 } MscSigChanEQsigProvEntry ::= SEQUENCE { mscSigChanEQsigSide INTEGER, mscSigChanEQsigMaxNonCallConcurrent Unsigned32, mscSigChanEQsigOverlapSendingEnabled INTEGER, mscSigChanEQsigOverlapReceivingEnabled INTEGER } mscSigChanEQsigSide OBJECT-TYPE SYNTAX INTEGER { network(1), user(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies whether the interface is the network or user side of the connection. The parameter applies to both the layer 2 and layer 3 of the interface. If this attribute is set to network, then the interface is master during channel negotiation. If this attribute is set to user, then the interface is slave during channel negotiation." DEFVAL { network } ::= { mscSigChanEQsigProvEntry 1 } mscSigChanEQsigMaxNonCallConcurrent OBJECT-TYPE SYNTAX Unsigned32 (1..30) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the maximum number of simultaneous active non-call messages that are allowed." DEFVAL { 30 } ::= { mscSigChanEQsigProvEntry 2 } mscSigChanEQsigOverlapSendingEnabled OBJECT-TYPE SYNTAX INTEGER { enabled(0), disabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies whether overlap sending to the PBX is enabled." DEFVAL { enabled } ::= { mscSigChanEQsigProvEntry 3 } mscSigChanEQsigOverlapReceivingEnabled OBJECT-TYPE SYNTAX INTEGER { enabled(0), disabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies whether overlap receiving from the PBX is enabled." DEFVAL { enabled } ::= { mscSigChanEQsigProvEntry 4 } mscSigChanEQsigStateTable OBJECT-TYPE SYNTAX SEQUENCE OF MscSigChanEQsigStateEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This group contains the three OSI State attributes. The descriptions generically indicate what each state attribute implies about the component. Note that not all the values and state combinations described here are supported by every component which uses this group. For component-specific information and the valid state combinations, refer to NTP 241-7001-150, Passport Operations and Maintenance Guide." ::= { mscSigChanEQsig 14 } mscSigChanEQsigStateEntry OBJECT-TYPE SYNTAX MscSigChanEQsigStateEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscSigChanEQsigStateTable." INDEX { mscSigChanIndex, mscSigChanEQsigIndex } ::= { mscSigChanEQsigStateTable 1 } MscSigChanEQsigStateEntry ::= SEQUENCE { mscSigChanEQsigAdminState INTEGER, mscSigChanEQsigOperationalState INTEGER, mscSigChanEQsigUsageState INTEGER } mscSigChanEQsigAdminState OBJECT-TYPE SYNTAX INTEGER { locked(0), unlocked(1), shuttingDown(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the OSI Administrative State of the component. The value locked indicates that the component is administratively prohibited from providing services for its users. A Lock or Lock - force command has been previously issued for this component. When the value is locked, the value of usageState must be idle. The value shuttingDown indicates that the component is administratively permitted to provide service to its existing users only. A Lock command was issued against the component and it is in the process of shutting down. The value unlocked indicates that the component is administratively permitted to provide services for its users. To enter this state, issue an Unlock command to this component." DEFVAL { unlocked } ::= { mscSigChanEQsigStateEntry 1 } mscSigChanEQsigOperationalState OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the OSI Operational State of the component. The value enabled indicates that the component is available for operation. Note that if adminState is locked, it would still not be providing service. The value disabled indicates that the component is not available for operation. For example, something is wrong with the component itself, or with another component on which this one depends. If the value is disabled, the usageState must be idle." DEFVAL { disabled } ::= { mscSigChanEQsigStateEntry 2 } mscSigChanEQsigUsageState OBJECT-TYPE SYNTAX INTEGER { idle(0), active(1), busy(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the OSI Usage State of the component. The value idle indicates that the component is not currently in use. The value active indicates that the component is in use and has spare capacity to provide for additional users. The value busy indicates that the component is in use and has no spare operating capacity for additional users at this time." DEFVAL { idle } ::= { mscSigChanEQsigStateEntry 3 } mscSigChanEQsigStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF MscSigChanEQsigStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This group provides the operational components for the EtsiQsig component." ::= { mscSigChanEQsig 15 } mscSigChanEQsigStatsEntry OBJECT-TYPE SYNTAX MscSigChanEQsigStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscSigChanEQsigStatsTable." INDEX { mscSigChanIndex, mscSigChanEQsigIndex } ::= { mscSigChanEQsigStatsTable 1 } MscSigChanEQsigStatsEntry ::= SEQUENCE { mscSigChanEQsigTotalCallsToIf Unsigned32, mscSigChanEQsigTotalCallsFromIf Unsigned32, mscSigChanEQsigNonCallAssocSessionsToIf Unsigned32, mscSigChanEQsigNonCallAssocSessionsFromIf Unsigned32 } mscSigChanEQsigTotalCallsToIf OBJECT-TYPE SYNTAX Unsigned32 (0..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute counts the total number of calls that have been made to the interface. The value wraps when it reaches its maximum." DEFVAL { 0 } ::= { mscSigChanEQsigStatsEntry 2 } mscSigChanEQsigTotalCallsFromIf OBJECT-TYPE SYNTAX Unsigned32 (0..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute counts the total number of calls from the interface. The value wraps when it reaches its maximum." DEFVAL { 0 } ::= { mscSigChanEQsigStatsEntry 3 } mscSigChanEQsigNonCallAssocSessionsToIf OBJECT-TYPE SYNTAX Unsigned32 (0..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute counts the total number of non-call associated sessions to the interface. The value wraps when it reaches its maximum." DEFVAL { 0 } ::= { mscSigChanEQsigStatsEntry 4 } mscSigChanEQsigNonCallAssocSessionsFromIf OBJECT-TYPE SYNTAX Unsigned32 (0..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute counts the total number of non-call associated sessions from the interface. The value wraps when it reaches its maximum." DEFVAL { 0 } ::= { mscSigChanEQsigStatsEntry 5 } mscSigChanEQsigOperTable OBJECT-TYPE SYNTAX SEQUENCE OF MscSigChanEQsigOperEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This group provides the operational attributes for the EtsiQsig protocol." ::= { mscSigChanEQsig 16 } mscSigChanEQsigOperEntry OBJECT-TYPE SYNTAX MscSigChanEQsigOperEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscSigChanEQsigOperTable." INDEX { mscSigChanIndex, mscSigChanEQsigIndex } ::= { mscSigChanEQsigOperTable 1 } MscSigChanEQsigOperEntry ::= SEQUENCE { mscSigChanEQsigActiveChannels Unsigned32, mscSigChanEQsigActiveVoiceChannels Unsigned32, mscSigChanEQsigActiveDataChannels Unsigned32, mscSigChanEQsigPeakActiveChannels Unsigned32, mscSigChanEQsigPeakActiveVoiceChannels Unsigned32, mscSigChanEQsigPeakActiveDataChannels Unsigned32, mscSigChanEQsigDChanStatus INTEGER } mscSigChanEQsigActiveChannels OBJECT-TYPE SYNTAX Unsigned32 (0..128) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the number of currently active channels. This includes data and voice channels." DEFVAL { 0 } ::= { mscSigChanEQsigOperEntry 1 } mscSigChanEQsigActiveVoiceChannels OBJECT-TYPE SYNTAX Unsigned32 (0..128) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the number of channels that are currently carrying voice." DEFVAL { 0 } ::= { mscSigChanEQsigOperEntry 2 } mscSigChanEQsigActiveDataChannels OBJECT-TYPE SYNTAX Unsigned32 (0..128) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the number of channels that are currently carrying data. This does not include modem data." DEFVAL { 0 } ::= { mscSigChanEQsigOperEntry 3 } mscSigChanEQsigPeakActiveChannels OBJECT-TYPE SYNTAX Unsigned32 (0..128) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the maximum number of channels that have been active on this signalling channel during the last polling period." DEFVAL { 0 } ::= { mscSigChanEQsigOperEntry 4 } mscSigChanEQsigPeakActiveVoiceChannels OBJECT-TYPE SYNTAX Unsigned32 (0..128) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the maximum number of voice channels that have been active on this signalling channel during the last polling period." DEFVAL { 0 } ::= { mscSigChanEQsigOperEntry 5 } mscSigChanEQsigPeakActiveDataChannels OBJECT-TYPE SYNTAX Unsigned32 (0..128) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the maximum number of data channels that have been active on this signalling channel during the last polling period." DEFVAL { 0 } ::= { mscSigChanEQsigOperEntry 6 } mscSigChanEQsigDChanStatus OBJECT-TYPE SYNTAX INTEGER { outOfService(0), establishing(1), established(2), enabling(3), inService(4), restarting(5) } ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the state of the D-channel. outOfService means that there is no layer 2 or layer 3 connectivity to the PBX. establishing means that the signalling channel is attempting to stage the layer 2. established means that the layer 2 is enabled. If the signalling channel stays in the established state, then it is waiting for a restart from the PBX. enabling means that the resources for processing calls are being initialized. If the signalling channel stays in the enabling state then it is waiting for a restart acknowledgement from the PBX. inService means that the resources for processing calls are available. restarting means that the resources for call processing are being rei-initialized." ::= { mscSigChanEQsigOperEntry 7 } mscSigChanEQsigToolsTable OBJECT-TYPE SYNTAX SEQUENCE OF MscSigChanEQsigToolsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This contains a series of operational attributes which turn on and off several kinds of tracing." ::= { mscSigChanEQsig 17 } mscSigChanEQsigToolsEntry OBJECT-TYPE SYNTAX MscSigChanEQsigToolsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscSigChanEQsigToolsTable." INDEX { mscSigChanIndex, mscSigChanEQsigIndex } ::= { mscSigChanEQsigToolsTable 1 } MscSigChanEQsigToolsEntry ::= SEQUENCE { mscSigChanEQsigTracing OCTET STRING } mscSigChanEQsigTracing OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1)) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute defines which types of tracing are active for this signalling channel. The tracing messages are sent to the debug stream. To see the messages the agentQueue attribute in Col/debug must be greater than 0 and a Telnet NMIS session must list the debug stream in in its data streams (ex. set nmis telnet session/1 dataStreams debug). Different types of tracing can be enabled simultaneously. Note that tracing consumes additional CPU resources and will slow down call processing on a heavily loaded card. If there is message block exhaustion tracing will be suspended for a period and then automatically reenabled. An alarm is generated on tracing suspension and resumption. This mechanism protects the function processor against excessive numbers of tracing messages. Types of tracing include: protocolErrors - get details of any protocol errors which are occuring. Protocol errors are also reported in summary form as alarms. q931Summary - Summary of the Q.931 messages on the signalling link, including certain call details (calling number, called number, release codes). q931Hex - Q.931 messages displayed in hex format. Useful to determine protocol compliance in case of errors reported on local or remote ends. q931Symbolic - Q.931 messages parsed to give maximum detail. Useful for understanding content of messages flowing on the link. portHex - Messages in hex format being sent and received on the link. Description of bits: protocolErrors(0) q931Summary(1) q931Hex(2) q931Symbolic(3) portHex(4)" ::= { mscSigChanEQsigToolsEntry 1 } mscSigChanEQsigEQsigSpecificProvTable OBJECT-TYPE SYNTAX SEQUENCE OF MscSigChanEQsigEQsigSpecificProvEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This group provides EtsiQsig protocol specific provisioning." ::= { mscSigChanEQsig 18 } mscSigChanEQsigEQsigSpecificProvEntry OBJECT-TYPE SYNTAX MscSigChanEQsigEQsigSpecificProvEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscSigChanEQsigEQsigSpecificProvTable." INDEX { mscSigChanIndex, mscSigChanEQsigIndex } ::= { mscSigChanEQsigEQsigSpecificProvTable 1 } MscSigChanEQsigEQsigSpecificProvEntry ::= SEQUENCE { mscSigChanEQsigMsgSegmentation INTEGER, mscSigChanEQsigE1ChannelNumbers INTEGER } mscSigChanEQsigMsgSegmentation OBJECT-TYPE SYNTAX INTEGER { enabled(0), disabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute allows users to enable/disable the EtsiQsig message segmentation service." DEFVAL { disabled } ::= { mscSigChanEQsigEQsigSpecificProvEntry 1 } mscSigChanEQsigE1ChannelNumbers OBJECT-TYPE SYNTAX INTEGER { skip16(1), contiguous(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute is applicable to E1 interfaces only. It specifies the mapping scheme between channel numbers (identified in Layer 3 messages) and timeslot numbers on the E1 link. When the attribute value is skip16, channel numbers map directly to actual E1 timeslots; therefore only channel numbers 1 - 15 and 17 - 31 are expected. When the value is contiguous, channel numbers from 1 - 30 are expected, and the following mapping is used: channels 1 - 15 are mapped to timeslots 1 - 15, and channels 16 - 30 are mapped to timeslots 17 - 31. On T1 interfaces, channel numbers are always expected in the range 1 - 23." DEFVAL { skip16 } ::= { mscSigChanEQsigEQsigSpecificProvEntry 2 } mscSigChanEQsigEQsigSpecificOpTable OBJECT-TYPE SYNTAX SEQUENCE OF MscSigChanEQsigEQsigSpecificOpEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This group provides specific operational attributes for the Etsi Qsig protocol." ::= { mscSigChanEQsig 19 } mscSigChanEQsigEQsigSpecificOpEntry OBJECT-TYPE SYNTAX MscSigChanEQsigEQsigSpecificOpEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscSigChanEQsigEQsigSpecificOpTable." INDEX { mscSigChanIndex, mscSigChanEQsigIndex } ::= { mscSigChanEQsigEQsigSpecificOpTable 1 } MscSigChanEQsigEQsigSpecificOpEntry ::= SEQUENCE { mscSigChanEQsigSegmentationAccepted Unsigned32, mscSigChanEQsigSegmentationFailed Unsigned32 } mscSigChanEQsigSegmentationAccepted OBJECT-TYPE SYNTAX Unsigned32 (0..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute counts the total number of times a long Etsi Qsig message has been received from a PBX and forwarded to a Passport subnet. The value wraps when it reaches its maximum." DEFVAL { 0 } ::= { mscSigChanEQsigEQsigSpecificOpEntry 1 } mscSigChanEQsigSegmentationFailed OBJECT-TYPE SYNTAX Unsigned32 (0..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute counts the total number of times a long Etsi Qsig message has been received from a PBX and could not be forwarded as is to a Passport subnet due to end-to-end incompatibility. The value wraps when it reaches its maximum." DEFVAL { 0 } ::= { mscSigChanEQsigEQsigSpecificOpEntry 2 } -- SigChan/n EQsig Framer -- -- The Framer component controls link layer framing for application -- components sending and receiving data on a link interface. It is also -- through Framer, that an application component is associated with a -- specific hardware link interface. -- -- The Framer component provides provisionable attributes related to -- data path aspects of the hardware interface (such as crc and frame -- length). The Framer component also provides a provisionable -- attribute which binds the application component to a specific -- hardware component. -- -- The Framer component contains operational attributes for link -- interface data path statistics (such as frame counts and aborts). -- mscSigChanEQsigFramer OBJECT IDENTIFIER ::= { mscSigChanEQsig 2 } mscSigChanEQsigFramerRowStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF MscSigChanEQsigFramerRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This entry controls the addition and deletion of mscSigChanEQsigFramer components." ::= { mscSigChanEQsigFramer 1 } mscSigChanEQsigFramerRowStatusEntry OBJECT-TYPE SYNTAX MscSigChanEQsigFramerRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A single entry in the table represents a single mscSigChanEQsigFramer component." INDEX { mscSigChanIndex, mscSigChanEQsigIndex, mscSigChanEQsigFramerIndex } ::= { mscSigChanEQsigFramerRowStatusTable 1 } MscSigChanEQsigFramerRowStatusEntry ::= SEQUENCE { mscSigChanEQsigFramerRowStatus RowStatus, mscSigChanEQsigFramerComponentName DisplayString, mscSigChanEQsigFramerStorageType StorageType, mscSigChanEQsigFramerIndex NonReplicated } mscSigChanEQsigFramerRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-only STATUS mandatory DESCRIPTION "This variable is used as the basis for SNMP naming of mscSigChanEQsigFramer components. These components cannot be added nor deleted." ::= { mscSigChanEQsigFramerRowStatusEntry 1 } mscSigChanEQsigFramerComponentName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This variable provides the component's string name for use with the ASCII Console Interface" ::= { mscSigChanEQsigFramerRowStatusEntry 2 } mscSigChanEQsigFramerStorageType OBJECT-TYPE SYNTAX StorageType ACCESS read-only STATUS mandatory DESCRIPTION "This variable represents the storage type value for the mscSigChanEQsigFramer tables." ::= { mscSigChanEQsigFramerRowStatusEntry 4 } mscSigChanEQsigFramerIndex OBJECT-TYPE SYNTAX NonReplicated ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable represents the index for the mscSigChanEQsigFramer tables." ::= { mscSigChanEQsigFramerRowStatusEntry 10 } mscSigChanEQsigFramerProvTable OBJECT-TYPE SYNTAX SEQUENCE OF MscSigChanEQsigFramerProvEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This group contains the base provisioning data for the Framer component. Application or hardware interface specific provisioning data is contained in other provisionable Framer groups." ::= { mscSigChanEQsigFramer 10 } mscSigChanEQsigFramerProvEntry OBJECT-TYPE SYNTAX MscSigChanEQsigFramerProvEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscSigChanEQsigFramerProvTable." INDEX { mscSigChanIndex, mscSigChanEQsigIndex, mscSigChanEQsigFramerIndex } ::= { mscSigChanEQsigFramerProvTable 1 } MscSigChanEQsigFramerProvEntry ::= SEQUENCE { mscSigChanEQsigFramerInterfaceName Link } mscSigChanEQsigFramerInterfaceName OBJECT-TYPE SYNTAX Link ACCESS read-write STATUS mandatory DESCRIPTION "This attribute contains a hardware component name. The attribute associates the application with a specific link. This defines the module processor on which Framer's parent component (as well as Framer itself) will run." ::= { mscSigChanEQsigFramerProvEntry 1 } mscSigChanEQsigFramerStateTable OBJECT-TYPE SYNTAX SEQUENCE OF MscSigChanEQsigFramerStateEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This group contains the three OSI State attributes. The descriptions generically indicate what each state attribute implies about the component. Note that not all the values and state combinations described here are supported by every component which uses this group. For component-specific information and the valid state combinations, refer to NTP 241-7001-150, Passport Operations and Maintenance Guide." ::= { mscSigChanEQsigFramer 12 } mscSigChanEQsigFramerStateEntry OBJECT-TYPE SYNTAX MscSigChanEQsigFramerStateEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscSigChanEQsigFramerStateTable." INDEX { mscSigChanIndex, mscSigChanEQsigIndex, mscSigChanEQsigFramerIndex } ::= { mscSigChanEQsigFramerStateTable 1 } MscSigChanEQsigFramerStateEntry ::= SEQUENCE { mscSigChanEQsigFramerAdminState INTEGER, mscSigChanEQsigFramerOperationalState INTEGER, mscSigChanEQsigFramerUsageState INTEGER } mscSigChanEQsigFramerAdminState OBJECT-TYPE SYNTAX INTEGER { locked(0), unlocked(1), shuttingDown(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the OSI Administrative State of the component. The value locked indicates that the component is administratively prohibited from providing services for its users. A Lock or Lock - force command has been previously issued for this component. When the value is locked, the value of usageState must be idle. The value shuttingDown indicates that the component is administratively permitted to provide service to its existing users only. A Lock command was issued against the component and it is in the process of shutting down. The value unlocked indicates that the component is administratively permitted to provide services for its users. To enter this state, issue an Unlock command to this component." DEFVAL { unlocked } ::= { mscSigChanEQsigFramerStateEntry 1 } mscSigChanEQsigFramerOperationalState OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the OSI Operational State of the component. The value enabled indicates that the component is available for operation. Note that if adminState is locked, it would still not be providing service. The value disabled indicates that the component is not available for operation. For example, something is wrong with the component itself, or with another component on which this one depends. If the value is disabled, the usageState must be idle." DEFVAL { disabled } ::= { mscSigChanEQsigFramerStateEntry 2 } mscSigChanEQsigFramerUsageState OBJECT-TYPE SYNTAX INTEGER { idle(0), active(1), busy(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the OSI Usage State of the component. The value idle indicates that the component is not currently in use. The value active indicates that the component is in use and has spare capacity to provide for additional users. The value busy indicates that the component is in use and has no spare operating capacity for additional users at this time." DEFVAL { idle } ::= { mscSigChanEQsigFramerStateEntry 3 } mscSigChanEQsigFramerStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF MscSigChanEQsigFramerStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This group contains the operational statistics data for a Framer component." ::= { mscSigChanEQsigFramer 13 } mscSigChanEQsigFramerStatsEntry OBJECT-TYPE SYNTAX MscSigChanEQsigFramerStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscSigChanEQsigFramerStatsTable." INDEX { mscSigChanIndex, mscSigChanEQsigIndex, mscSigChanEQsigFramerIndex } ::= { mscSigChanEQsigFramerStatsTable 1 } MscSigChanEQsigFramerStatsEntry ::= SEQUENCE { mscSigChanEQsigFramerFrmToIf Unsigned32, mscSigChanEQsigFramerFrmFromIf Unsigned32, mscSigChanEQsigFramerOctetFromIf Unsigned32, mscSigChanEQsigFramerAborts Unsigned32, mscSigChanEQsigFramerCrcErrors Unsigned32, mscSigChanEQsigFramerLrcErrors Unsigned32, mscSigChanEQsigFramerNonOctetErrors Unsigned32, mscSigChanEQsigFramerOverruns Unsigned32, mscSigChanEQsigFramerUnderruns Unsigned32, mscSigChanEQsigFramerLargeFrmErrors Unsigned32 } mscSigChanEQsigFramerFrmToIf OBJECT-TYPE SYNTAX Unsigned32 (0..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute counts the number of frames transmitted to the link interface by Framer. This count wraps to zero after reaching its maximum value." DEFVAL { 0 } ::= { mscSigChanEQsigFramerStatsEntry 1 } mscSigChanEQsigFramerFrmFromIf OBJECT-TYPE SYNTAX Unsigned32 (0..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute counts the number of frames received from the link interface by Framer. This count wraps to zero after reaching its maximum value." DEFVAL { 0 } ::= { mscSigChanEQsigFramerStatsEntry 2 } mscSigChanEQsigFramerOctetFromIf OBJECT-TYPE SYNTAX Unsigned32 (0..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "The number of bytes received from the link interface by Framer." DEFVAL { 0 } ::= { mscSigChanEQsigFramerStatsEntry 3 } mscSigChanEQsigFramerAborts OBJECT-TYPE SYNTAX Unsigned32 (0..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute counts the total number of aborts received. This count wraps to zero after reaching its maximum value." DEFVAL { 0 } ::= { mscSigChanEQsigFramerStatsEntry 4 } mscSigChanEQsigFramerCrcErrors OBJECT-TYPE SYNTAX Unsigned32 (0..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute counts the total number of frames with CRC errors. This count wraps to zero after reaching its maximum value." DEFVAL { 0 } ::= { mscSigChanEQsigFramerStatsEntry 5 } mscSigChanEQsigFramerLrcErrors OBJECT-TYPE SYNTAX Unsigned32 (0..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute counts the total number of frames with LRC errors. This count wraps to zero after reaching its maximum value." DEFVAL { 0 } ::= { mscSigChanEQsigFramerStatsEntry 6 } mscSigChanEQsigFramerNonOctetErrors OBJECT-TYPE SYNTAX Unsigned32 (0..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute counts the total number of frames that were non octet aligned. This count wraps to zero after reaching its maximum value." DEFVAL { 0 } ::= { mscSigChanEQsigFramerStatsEntry 7 } mscSigChanEQsigFramerOverruns OBJECT-TYPE SYNTAX Unsigned32 (0..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute counts the total number of frames received from the link for which overruns occurred. This count wraps to zero after reaching its maximum value." DEFVAL { 0 } ::= { mscSigChanEQsigFramerStatsEntry 8 } mscSigChanEQsigFramerUnderruns OBJECT-TYPE SYNTAX Unsigned32 (0..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute counts the total number of frames transmitted to the link for which underruns occurred. This count wraps to zero after reaching its maximum value." DEFVAL { 0 } ::= { mscSigChanEQsigFramerStatsEntry 9 } mscSigChanEQsigFramerLargeFrmErrors OBJECT-TYPE SYNTAX Unsigned32 (0..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute counts the total number of frames received which were too large (longer than 500 bytes). This count wraps to zero after reaching its maximum value." DEFVAL { 0 } ::= { mscSigChanEQsigFramerStatsEntry 10 } -- -- Version and Compliance statements -- -- Object-Group Statement: -- A list of all current accessible leaf objects. -- OBJECTS { mscSigChanEQsigFramerAdminState, -- mscSigChanEQsigOverlapSendingEnabled, -- mscSigChanEQsigFramerStorageType, -- mscSigChanEQsigFramerLrcErrors, -- mscSigChanEQsigOverlapReceivingEnabled, -- mscSigChanEQsigFramerOctetFromIf, -- mscSigChanEQsigAdminState, -- mscSigChanEQsigActiveChannels, -- mscSigChanEQsigActiveVoiceChannels, -- mscSigChanEQsigT310, -- mscSigChanEQsigRowStatus, -- mscSigChanEQsigFramerOverruns, -- mscSigChanEQsigTotalCallsFromIf, -- mscSigChanEQsigMaxNonCallConcurrent, -- mscSigChanEQsigFramerOperationalState, -- mscSigChanEQsigNonCallAssocSessionsFromIf, -- mscSigChanEQsigPeakActiveVoiceChannels, -- mscSigChanEQsigFramerNonOctetErrors, -- mscSigChanEQsigPeakActiveChannels, -- mscSigChanEQsigCircuitSwitchedK, -- mscSigChanEQsigSegmentationFailed, -- mscSigChanEQsigFramerFrmToIf, -- mscSigChanEQsigActiveDataChannels, -- mscSigChanEQsigSegmentationAccepted, -- mscSigChanEQsigFramerUsageState, -- mscSigChanEQsigFramerComponentName, -- mscSigChanEQsigUsageState, -- mscSigChanEQsigFramerAborts, -- mscSigChanEQsigN200, -- mscSigChanEQsigSide, -- mscSigChanEQsigFramerInterfaceName, -- mscSigChanEQsigComponentName, -- mscSigChanEQsigT23, -- mscSigChanEQsigTotalCallsToIf, -- mscSigChanEQsigPeakActiveDataChannels, -- mscSigChanEQsigFramerUnderruns, -- mscSigChanEQsigFramerCrcErrors, -- mscSigChanEQsigNonCallAssocSessionsToIf, -- mscSigChanEQsigFramerRowStatus, -- mscSigChanEQsigTracing, -- mscSigChanEQsigT200, -- mscSigChanEQsigE1ChannelNumbers, -- mscSigChanEQsigT309, -- mscSigChanEQsigMsgSegmentation, -- mscSigChanEQsigOperationalState, -- mscSigChanEQsigStorageType, -- mscSigChanEQsigT203, -- mscSigChanEQsigFramerFrmFromIf, -- mscSigChanEQsigFramerLargeFrmErrors, -- mscSigChanEQsigDChanStatus } -- STATUS mandatory -- DESCRIPTION -- "A list of all current accessible leaf objects." vnetEtsiQsigGroup OBJECT IDENTIFIER ::= { vnetEtsiQsigMIB 1 } vnetEtsiQsigGroupCA OBJECT IDENTIFIER ::= { vnetEtsiQsigGroup 1 } vnetEtsiQsigGroupCA02 OBJECT IDENTIFIER ::= { vnetEtsiQsigGroupCA 3 } vnetEtsiQsigGroupCA02A OBJECT IDENTIFIER ::= { vnetEtsiQsigGroupCA02 2 } -- Agent-Capabilities Statement: -- PRODUCT-RELEASE "MscPassport Release 1.2 VnetEtsiQsig." -- STATUS mandatory -- DESCRIPTION "Carrier Passport VnetEtsiQsig MIB: MIB Version CA02A, -- Software Version CA02S9C." -- SUPPORTS Nortel-MsCarrier-MscPassport-VnetEtsiQsigMIB -- INCLUDES { vnetEtsiQsigGroupCA02A } vnetEtsiQsigCapabilities OBJECT IDENTIFIER ::= { vnetEtsiQsigMIB 3 } vnetEtsiQsigCapabilitiesCA OBJECT IDENTIFIER ::= { vnetEtsiQsigCapabilities 1 } vnetEtsiQsigCapabilitiesCA02 OBJECT IDENTIFIER ::= { vnetEtsiQsigCapabilitiesCA 3 } vnetEtsiQsigCapabilitiesCA02A OBJECT IDENTIFIER ::= { vnetEtsiQsigCapabilitiesCA02 2 } END