Nortel-MsCarrier-MscPassport-SubnetInterfaceMIB DEFINITIONS ::= BEGIN IMPORTS OBJECT-TYPE FROM RFC-1212 mscPassportMIBs FROM Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB DisplayString, StorageType, RowStatus, Integer32, Unsigned32 FROM Nortel-MsCarrier-MscPassport-StandardTextualConventionsMIB NonReplicated, DigitString FROM Nortel-MsCarrier-MscPassport-TextualConventionsMIB mscMod, mscModIndex FROM Nortel-MsCarrier-MscPassport-BaseShelfMIB; -- LAST-UPDATED "9909010000Z" -- ORGANIZATION "Nortel Networks" -- CONTACT-INFO " -- Nortel Carrier Data Network Management -- -- Postal: P.O. Box 3511, Station C -- Ottawa, Ontario -- Canada K1Y 4H7 -- -- via the WEB: http://www.nortelnetworks.com -- select 'Contact Us' from the menu -- -- via phone: 1-800-4NORTEL" -- DESCRIPTION -- "The module describing the Nortel MsCarrier MscPassport -- SubnetInterface Enterprise MIB." subnetInterfaceMIB OBJECT IDENTIFIER ::= { mscPassportMIBs 45 } -- -- ModuleData Vcs -- ModuleData VirtualCircuitSystem is used to define a number of -- general characteristics for all Vcs that originate from or terminate -- on a particular module. As an example, the Vc Window matrix is -- defined on a module basis to provide the expected virtual circuit -- window sizes to associate with all Vcs on the module. All the -- modules in the network should have identical VirtualCircuitSystem -- attributes. If these attributes are not consistent across the network -- applications which need Vc may not be able to establish calls. mscModVcs OBJECT IDENTIFIER ::= { mscMod 2 } mscModVcsRowStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF MscModVcsRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This entry controls the addition and deletion of mscModVcs components." ::= { mscModVcs 1 } mscModVcsRowStatusEntry OBJECT-TYPE SYNTAX MscModVcsRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A single entry in the table represents a single mscModVcs component." INDEX { mscModIndex, mscModVcsIndex } ::= { mscModVcsRowStatusTable 1 } MscModVcsRowStatusEntry ::= SEQUENCE { mscModVcsRowStatus RowStatus, mscModVcsComponentName DisplayString, mscModVcsStorageType StorageType, mscModVcsIndex NonReplicated } mscModVcsRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-write STATUS mandatory DESCRIPTION "This variable is used as the basis for SNMP naming of mscModVcs components. These components can be added and deleted." ::= { mscModVcsRowStatusEntry 1 } mscModVcsComponentName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This variable provides the component's string name for use with the ASCII Console Interface" ::= { mscModVcsRowStatusEntry 2 } mscModVcsStorageType OBJECT-TYPE SYNTAX StorageType ACCESS read-only STATUS mandatory DESCRIPTION "This variable represents the storage type value for the mscModVcs tables." ::= { mscModVcsRowStatusEntry 4 } mscModVcsIndex OBJECT-TYPE SYNTAX NonReplicated ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable represents the index for the mscModVcs tables." ::= { mscModVcsRowStatusEntry 10 } mscModVcsAccOptTable OBJECT-TYPE SYNTAX SEQUENCE OF MscModVcsAccOptEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Accounting information is owned by the Vc System; it is stored in the Vc Accounting component, which itself is considered to be a component on the switch. The Accounting Component contains a bit map indicating which of the accounting facilities are to be spooled in the accounting record - for example, bit '0' if set indicates that the accounting facility with facility code H.00 should be spooled if present in the Vc for accounting purposes. The data contained in the Vc Accounting must be identical network wide even though the component can be changed and upgraded on a module by module basis." ::= { mscModVcs 10 } mscModVcsAccOptEntry OBJECT-TYPE SYNTAX MscModVcsAccOptEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscModVcsAccOptTable." INDEX { mscModIndex, mscModVcsIndex } ::= { mscModVcsAccOptTable 1 } MscModVcsAccOptEntry ::= SEQUENCE { mscModVcsSegmentSize INTEGER, mscModVcsUnitsCounted INTEGER, mscModVcsAccountingFax OCTET STRING, mscModVcsGenerationMode INTEGER } mscModVcsSegmentSize OBJECT-TYPE SYNTAX INTEGER { n1(0), n2(1), n4(2), n8(3), n16(4), n32(5), n64(6), n128(7), n256(8), n512(9), n1024(10), n2048(11), n4096(12) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the segment size for accounting of national calls. Minimum allowed segment size is 1. If data segment is sent which is less than segmentSize it is still counted as one segment." DEFVAL { n128 } ::= { mscModVcsAccOptEntry 1 } mscModVcsUnitsCounted OBJECT-TYPE SYNTAX INTEGER { segments(0), frames(1) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies what is counted by frame services. If set to frames, frames are counted, else segments are counted." DEFVAL { segments } ::= { mscModVcsAccOptEntry 2 } mscModVcsAccountingFax OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1)) ACCESS read-write STATUS mandatory DESCRIPTION "Each value corresponds to an accounting facility code, of which there are currently 10 facility codes defined with codes H.00 to H.09, and corresponding to the above 10 facilities. Each of the above facilities may or may not be present and stored in the Vc for accounting purposes, depending on the nature of the call. For example, only those Vcs where a NUI (Network User Identifier) is used for charging or identification purposes will have a NUI stored in the Vc. Description of bits: notused0(0) notused1(1) originalCalledAddressFax(2)" DEFVAL { '20'H } ::= { mscModVcsAccOptEntry 3 } mscModVcsGenerationMode OBJECT-TYPE SYNTAX INTEGER { bothEnds(0), singleEnd(1) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies part of the rules by which the network generates accounting records. If set to bothEnds, then both ends of the Vc generate accounting records. If set to singleEnd, then the charged end of the Vc generates accounting records. In single end generation mode, if the call does not clear gracefully, both ends of the Vc will generate accounting record." DEFVAL { singleEnd } ::= { mscModVcsAccOptEntry 4 } mscModVcsAddOptTable OBJECT-TYPE SYNTAX SEQUENCE OF MscModVcsAddOptEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The Vc AddressingOptions group describes the addressing parameters. It is currently owned by the Vc. Most of the data contained in the Vc AddressingOptions group is identical network wide even though the group can be changed and upgraded on a module by module basis." ::= { mscModVcs 12 } mscModVcsAddOptEntry OBJECT-TYPE SYNTAX MscModVcsAddOptEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscModVcsAddOptTable." INDEX { mscModIndex, mscModVcsIndex } ::= { mscModVcsAddOptTable 1 } MscModVcsAddOptEntry ::= SEQUENCE { mscModVcsDefaultNumberingPlan INTEGER, mscModVcsNetworkIdType INTEGER, mscModVcsX121Type INTEGER, mscModVcsNetworkIdCode DigitString, mscModVcsX121IntlAddresses INTEGER, mscModVcsX121IntllPrefixDigit Unsigned32, mscModVcsX121MinAddressLength Unsigned32, mscModVcsX121MaxAddressLength Unsigned32, mscModVcsX121ToE164EscapeSignificance INTEGER, mscModVcsE164IntlFormatAllowed INTEGER, mscModVcsE164IntlPrefixDigits DigitString, mscModVcsE164NatlPrefixDigit Unsigned32, mscModVcsE164LocalAddressLength Unsigned32, mscModVcsE164TeleCountryCode DigitString, mscModVcsE164NatlMinAddressLength Unsigned32, mscModVcsE164NatlMaxAddressLength Unsigned32, mscModVcsE164IntlMinAddressLength Unsigned32, mscModVcsE164IntlMaxAddressLength Unsigned32, mscModVcsE164LocalMinAddressLength Unsigned32, mscModVcsE164LocalMaxAddressLength Unsigned32 } mscModVcsDefaultNumberingPlan OBJECT-TYPE SYNTAX INTEGER { x121(0), e164(1) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the numbering plan used which determines the address format: X.121-- the international numbering plan for public packet switched data networks or E.164-- the international numbering plan for ISDN and PSTN. The default numbering plan does not need to be consistent across all of the nodes in the network." DEFVAL { x121 } ::= { mscModVcsAddOptEntry 3 } mscModVcsNetworkIdType OBJECT-TYPE SYNTAX INTEGER { dnic(0), inic(1) } ACCESS read-only STATUS mandatory DESCRIPTION "This attribute specifies whether the network uses a DNIC or INIC. It is used by X.75 Gateways to indicate whether in network the DNIC or INIC is used in various utilities. If it is DNIC it can be DNIC or DCC type. If it is INIC it can be 4 digits only." DEFVAL { dnic } ::= { mscModVcsAddOptEntry 4 } mscModVcsX121Type OBJECT-TYPE SYNTAX INTEGER { dnic(0), dcc(1) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies whether DNIC mode or DCC mode is used in X.121 address of international calls. If DCC is specified, then the first 3 digits of each DNA must be the Network ID Code. If this attribute is changed all Dnas in the network must start with this code. Numbering plan is affected by the change." DEFVAL { dnic } ::= { mscModVcsAddOptEntry 5 } mscModVcsNetworkIdCode OBJECT-TYPE SYNTAX DigitString (SIZE (3..4)) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the DNIC (Data Network ID Code) of the network or DCC code." ::= { mscModVcsAddOptEntry 6 } mscModVcsX121IntlAddresses OBJECT-TYPE SYNTAX INTEGER { disallowed(0), allowed(1) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute indicates if any DTE is allowed to signal international addresses." DEFVAL { allowed } ::= { mscModVcsAddOptEntry 7 } mscModVcsX121IntllPrefixDigit OBJECT-TYPE SYNTAX Unsigned32 (0..9) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute indicates the prefix digit to be used for X.121 international calls. When this digit is provided the call will have full international address." DEFVAL { 9 } ::= { mscModVcsAddOptEntry 8 } mscModVcsX121MinAddressLength OBJECT-TYPE SYNTAX Unsigned32 (1..16) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute indicates minimum length of x121 address." DEFVAL { 1 } ::= { mscModVcsAddOptEntry 11 } mscModVcsX121MaxAddressLength OBJECT-TYPE SYNTAX Unsigned32 (1..16) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute indicates maximum length of x121 address." DEFVAL { 15 } ::= { mscModVcsAddOptEntry 12 } mscModVcsX121ToE164EscapeSignificance OBJECT-TYPE SYNTAX INTEGER { no(0), yes(1) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies whether an X.121 to E.164 escape digit has significance in selecting an X.32 (analog) or an ISDN switched path. If two values are significant (the value 0 or the value 9) then yes is set to this attribute. If the value of the originally entered escape digit is not significant in routing the call then value of no is assigned to this attribute." DEFVAL { no } ::= { mscModVcsAddOptEntry 13 } mscModVcsE164IntlFormatAllowed OBJECT-TYPE SYNTAX INTEGER { disallowed(0), allowed(1) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute indicates whether or not to allow national format E.164 addresses. If this attribute is set to a value of Yes (=1) then national format E.164 addresses are not allowed and international format addresses only are allowed. If this attribute is set to a value of No (=0), then national format E.164 addresses are allowed. If only international format E.164 addresses are allowed, then the 'e164NatlPrefixDigit' attribute is not required, nor is the 'e164IntlPrefixDigits' required." DEFVAL { allowed } ::= { mscModVcsAddOptEntry 14 } mscModVcsE164IntlPrefixDigits OBJECT-TYPE SYNTAX DigitString (SIZE (0..3)) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the E.164 international prefix digits. If applicable, it is specified as 1 to 3 BCD digits. The 3 BCD digits are stored with the length of the international prefix in the low order nibble, nibble [0] followed by the most significant digit of the international prefix in the next low order nibble, nibble [1], etc. This attribute is not required if the corresponding attribute, 'e164IntlFormatOnly' is set to a value of Yes (=1)." DEFVAL { '30'H } -- "0" ::= { mscModVcsAddOptEntry 15 } mscModVcsE164NatlPrefixDigit OBJECT-TYPE SYNTAX Unsigned32 (0..9) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute contains the E.164 national prefix which may be added in front of E.164 local or national call. If e164IntlFormatOnly is set to 1, this attribute is not needed." DEFVAL { 1 } ::= { mscModVcsAddOptEntry 16 } mscModVcsE164LocalAddressLength OBJECT-TYPE SYNTAX Unsigned32 (4..15) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute indicates the length of a local E.164 DNA on this module. This attribute is not required if the corresponding attribute, e164IntlFormatOnly is set to a value of yes. This attribute does not need to be consistent across all of the nodes in the network." DEFVAL { 7 } ::= { mscModVcsAddOptEntry 17 } mscModVcsE164TeleCountryCode OBJECT-TYPE SYNTAX DigitString (SIZE (1..4)) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the E.164 Telephone Country Code (TCC) for the country in which the network resides. If applicable, it is specified as 1 to 3 BCD digits. The 3 BCD digits are stored with the length of the TCC in the low order nibble, nibble [0] followed by the most significant digit of the TCC in the next low order nibble, nibble [1], etc." DEFVAL { '31'H } -- "1" ::= { mscModVcsAddOptEntry 18 } mscModVcsE164NatlMinAddressLength OBJECT-TYPE SYNTAX Unsigned32 (1..16) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute indicates minimum length of e164 national address." DEFVAL { 1 } ::= { mscModVcsAddOptEntry 20 } mscModVcsE164NatlMaxAddressLength OBJECT-TYPE SYNTAX Unsigned32 (1..16) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute indicates maximum length of e164 national address." DEFVAL { 15 } ::= { mscModVcsAddOptEntry 21 } mscModVcsE164IntlMinAddressLength OBJECT-TYPE SYNTAX Unsigned32 (1..16) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute indicates minimum length of e164 international address." DEFVAL { 1 } ::= { mscModVcsAddOptEntry 22 } mscModVcsE164IntlMaxAddressLength OBJECT-TYPE SYNTAX Unsigned32 (1..16) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute indicates maximum length of e164 international address." DEFVAL { 15 } ::= { mscModVcsAddOptEntry 23 } mscModVcsE164LocalMinAddressLength OBJECT-TYPE SYNTAX Unsigned32 (1..16) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute indicates minimum length of e164 local address." DEFVAL { 1 } ::= { mscModVcsAddOptEntry 24 } mscModVcsE164LocalMaxAddressLength OBJECT-TYPE SYNTAX Unsigned32 (1..16) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute indicates maximum length of e164 local address." DEFVAL { 15 } ::= { mscModVcsAddOptEntry 25 } mscModVcsIntOptTable OBJECT-TYPE SYNTAX SEQUENCE OF MscModVcsIntOptEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The Vc InterfaceOptions group defines Vc system parameters common in the network. It is owned by the Vc and is considered to be a module wide component on the switch. The data contained in the Vc InterfaceOptions group must be identical network wide even though this group can be changed and upgraded on a module by module basis." ::= { mscModVcs 13 } mscModVcsIntOptEntry OBJECT-TYPE SYNTAX MscModVcsIntOptEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscModVcsIntOptTable." INDEX { mscModIndex, mscModVcsIndex } ::= { mscModVcsIntOptTable 1 } MscModVcsIntOptEntry ::= SEQUENCE { mscModVcsHighPriorityPacketSizes OCTET STRING, mscModVcsMaxSubnetPacketSize INTEGER, mscModVcsCallSetupTimer Unsigned32, mscModVcsCallRetryTimer Unsigned32, mscModVcsDelaySubnetAcks INTEGER } mscModVcsHighPriorityPacketSizes OBJECT-TYPE SYNTAX OCTET STRING (SIZE (2)) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates which packet sizes are supported for high priority calls within the network. Description of bits: n16(0) n32(1) n64(2) n128(3) n256(4) n512(5) n1024(6) n2048(7) n4096(8)" DEFVAL { 'ff80'H } ::= { mscModVcsIntOptEntry 1 } mscModVcsMaxSubnetPacketSize OBJECT-TYPE SYNTAX INTEGER { n16(4), n32(5), n64(6), n128(7), n256(8), n512(9), n1024(10), n2048(11), n4096(12) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the maximum subnet packet size used for the connections originating or terminating on this module. All modules in the same network should have the same maxSubnetPacketSize. If this value is not identical throughout the network, the following points need to be considered: a) When Passport and DPN switches are connected in the same network, the maxSubnetPacketSize on a DPN switch can be at most 2048 and the DPN part of the network must be configured with hardware which supports this size: - Dedicated PE386 Network link/Trunk - Minimum measured link speed of 256Kbits/sec This hardware has to be present on every potential data path between connecting end points! b) The calling end of the connection signals the maxSubnetPacketSize value to the called end. The called end then compares this value to its own provisioned value and selects the smaller value. Note that this smaller value is not signalled back to the calling end. The calling and called ends can therefore have different maxSubnetPacketSize values." DEFVAL { n512 } ::= { mscModVcsIntOptEntry 2 } mscModVcsCallSetupTimer OBJECT-TYPE SYNTAX Unsigned32 (5..100) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the Vc callSetupTimer in units of 1 second ticks. This timer specifies how long the Vc will wait, after sending a subnet Call Request packet into the network, for a response from the remote end of the Vc (in the form of a subnet Raccept packet). If, after sending a subnet Call packet into the network, a response is not received within this time period, the Vc will time out, clearing the call in the assumption that the remote end is unreachable. This timer must be long enough to take into account the time required for routing the subnet Call Request through the Source Call Routing and the Destination Call Routing systems in order to be delivered to the final destination." DEFVAL { 5 } ::= { mscModVcsIntOptEntry 3 } mscModVcsCallRetryTimer OBJECT-TYPE SYNTAX Unsigned32 (30..300) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies, for Vc implementing Direct Calls with the auto-call retry feature (including PVCs), the Vc callRetryTimer in units of 1 second ticks. This timer specifies how long the Vc will wait between unsuccessful call attempts." DEFVAL { 60 } ::= { mscModVcsIntOptEntry 4 } mscModVcsDelaySubnetAcks OBJECT-TYPE SYNTAX INTEGER { no(0), yes(1) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies delay acknowledgment timer mechanism. If this attribute is set to no, then the Vc will automatically return acknowledgment packets without delay. If this attribute is set to yes, then the Vc will wait for one second in an attempt to piggyback the acknowledgment packet on another credit or data packet. If the Vc cannot piggyback the acknowledgment packet within this time, then the packet is returned without piggybacking." DEFVAL { no } ::= { mscModVcsIntOptEntry 5 } mscModVcsWinsTable OBJECT-TYPE SYNTAX SEQUENCE OF MscModVcsWinsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This is the windowSize corresponding to the given packet size and throughput class. All Vcs using the windowSize matrix support large Vc windows on both ends of the Vc, and support the signalling of the chosen Vc window size from the destination (called) end to the source (calling) end. This is the only matrix supported. The windowSize should be configured in the same way network wide, though it can be upgraded on a module by module basis. Vcs using the windowSize matrix will run properly if the matrices on different nodes differ since the Vc window is selected by the destination (called) side of the Vc." ::= { mscModVcs 213 } mscModVcsWinsEntry OBJECT-TYPE SYNTAX MscModVcsWinsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscModVcsWinsTable." INDEX { mscModIndex, mscModVcsIndex, mscModVcsWinsPktIndex, mscModVcsWinsTptIndex } ::= { mscModVcsWinsTable 1 } MscModVcsWinsEntry ::= SEQUENCE { mscModVcsWinsPktIndex INTEGER, mscModVcsWinsTptIndex Integer32, mscModVcsWinsValue Unsigned32 } mscModVcsWinsPktIndex OBJECT-TYPE SYNTAX INTEGER { n16(0), n32(1), n64(2), n128(3), n256(4), n512(5), n1024(6), n2048(7), n4096(8), n8192(9), n32768(10), n65535(11) } ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable represents the next to last index for the mscModVcsWinsTable." ::= { mscModVcsWinsEntry 1 } mscModVcsWinsTptIndex OBJECT-TYPE SYNTAX Integer32 (0..15) ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable represents the final index for the mscModVcsWinsTable." ::= { mscModVcsWinsEntry 2 } mscModVcsWinsValue OBJECT-TYPE SYNTAX Unsigned32 (1..63) ACCESS read-write STATUS mandatory DESCRIPTION "This variable represents an individual value for the mscModVcsWinsTable." ::= { mscModVcsWinsEntry 3 } -- -- Version and Compliance statements -- -- Object-Group Statement: -- A list of all current accessible leaf objects. -- OBJECTS { mscModVcsGenerationMode, -- mscModVcsE164NatlMinAddressLength, -- mscModVcsUnitsCounted, -- mscModVcsAccountingFax, -- mscModVcsComponentName, -- mscModVcsNetworkIdType, -- mscModVcsX121ToE164EscapeSignificance, -- mscModVcsHighPriorityPacketSizes, -- mscModVcsE164TeleCountryCode, -- mscModVcsStorageType, -- mscModVcsE164LocalMinAddressLength, -- mscModVcsX121IntlAddresses, -- mscModVcsSegmentSize, -- mscModVcsE164IntlPrefixDigits, -- mscModVcsE164NatlPrefixDigit, -- mscModVcsX121MinAddressLength, -- mscModVcsE164NatlMaxAddressLength, -- mscModVcsCallSetupTimer, -- mscModVcsX121Type, -- mscModVcsMaxSubnetPacketSize, -- mscModVcsE164IntlMaxAddressLength, -- mscModVcsE164LocalMaxAddressLength, -- mscModVcsWinsValue, -- mscModVcsE164IntlMinAddressLength, -- mscModVcsE164IntlFormatAllowed, -- mscModVcsNetworkIdCode, -- mscModVcsRowStatus, -- mscModVcsDefaultNumberingPlan, -- mscModVcsX121MaxAddressLength, -- mscModVcsX121IntllPrefixDigit, -- mscModVcsE164LocalAddressLength, -- mscModVcsCallRetryTimer, -- mscModVcsDelaySubnetAcks } -- STATUS mandatory -- DESCRIPTION -- "A list of all current accessible leaf objects." subnetInterfaceGroup OBJECT IDENTIFIER ::= { subnetInterfaceMIB 1 } subnetInterfaceGroupCA OBJECT IDENTIFIER ::= { subnetInterfaceGroup 1 } subnetInterfaceGroupCA02 OBJECT IDENTIFIER ::= { subnetInterfaceGroupCA 3 } subnetInterfaceGroupCA02A OBJECT IDENTIFIER ::= { subnetInterfaceGroupCA02 2 } -- Agent-Capabilities Statement: -- PRODUCT-RELEASE "MscPassport Release 1.2 SubnetInterface." -- STATUS mandatory -- DESCRIPTION "Carrier Passport SubnetInterface MIB: MIB Version CA02A, -- Software Version CA02S9C." -- SUPPORTS Nortel-MsCarrier-MscPassport-SubnetInterfaceMIB -- INCLUDES { subnetInterfaceGroupCA02A } subnetInterfaceCapabilities OBJECT IDENTIFIER ::= { subnetInterfaceMIB 3 } subnetInterfaceCapabilitiesCA OBJECT IDENTIFIER ::= { subnetInterfaceCapabilities 1 } subnetInterfaceCapabilitiesCA02 OBJECT IDENTIFIER ::= { subnetInterfaceCapabilitiesCA 3 } subnetInterfaceCapabilitiesCA02A OBJECT IDENTIFIER ::= { subnetInterfaceCapabilitiesCA02 2 } END