Nortel-MsCarrier-MscPassport-DisdnJapanInsMIB DEFINITIONS ::= BEGIN IMPORTS OBJECT-TYPE FROM RFC-1212 mscPassportMIBs FROM Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB DisplayString, StorageType, RowStatus, Unsigned32 FROM Nortel-MsCarrier-MscPassport-StandardTextualConventionsMIB NonReplicated, Link FROM Nortel-MsCarrier-MscPassport-TextualConventionsMIB mscDataSigChanIndex, mscDataSigChan FROM Nortel-MsCarrier-MscPassport-DataIsdnMIB; -- LAST-UPDATED "9909010000Z" -- ORGANIZATION "Nortel Networks" -- CONTACT-INFO " -- Nortel Carrier Data Network Management -- -- Postal: P.O. Box 3511, Station C -- Ottawa, Ontario -- Canada K1Y 4H7 -- -- via the WEB: http://www.nortelnetworks.com -- select 'Contact Us' from the menu -- -- via phone: 1-800-4NORTEL" -- DESCRIPTION -- "The module describing the Nortel MsCarrier MscPassport -- DisdnJapanIns Enterprise MIB." disdnJapanInsMIB OBJECT IDENTIFIER ::= { mscPassportMIBs 118 } -- DataSigChan/n JapanIns -- The JapanIns component defines the operational characteristics of -- the signalling channel's connection to the external equipment. mscDataSigChanIns OBJECT IDENTIFIER ::= { mscDataSigChan 11 } mscDataSigChanInsRowStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF MscDataSigChanInsRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This entry controls the addition and deletion of mscDataSigChanIns components." ::= { mscDataSigChanIns 1 } mscDataSigChanInsRowStatusEntry OBJECT-TYPE SYNTAX MscDataSigChanInsRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A single entry in the table represents a single mscDataSigChanIns component." INDEX { mscDataSigChanIndex, mscDataSigChanInsIndex } ::= { mscDataSigChanInsRowStatusTable 1 } MscDataSigChanInsRowStatusEntry ::= SEQUENCE { mscDataSigChanInsRowStatus RowStatus, mscDataSigChanInsComponentName DisplayString, mscDataSigChanInsStorageType StorageType, mscDataSigChanInsIndex NonReplicated } mscDataSigChanInsRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-write STATUS mandatory DESCRIPTION "This variable is used as the basis for SNMP naming of mscDataSigChanIns components. These components can be added and deleted." ::= { mscDataSigChanInsRowStatusEntry 1 } mscDataSigChanInsComponentName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This variable provides the component's string name for use with the ASCII Console Interface" ::= { mscDataSigChanInsRowStatusEntry 2 } mscDataSigChanInsStorageType OBJECT-TYPE SYNTAX StorageType ACCESS read-only STATUS mandatory DESCRIPTION "This variable represents the storage type value for the mscDataSigChanIns tables." ::= { mscDataSigChanInsRowStatusEntry 4 } mscDataSigChanInsIndex OBJECT-TYPE SYNTAX NonReplicated ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable represents the index for the mscDataSigChanIns tables." ::= { mscDataSigChanInsRowStatusEntry 10 } mscDataSigChanInsL2Table OBJECT-TYPE SYNTAX SEQUENCE OF MscDataSigChanInsL2Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "This group represents the provisionable Layer 2 attributes of the Q931 CCITT protocol." ::= { mscDataSigChanIns 11 } mscDataSigChanInsL2Entry OBJECT-TYPE SYNTAX MscDataSigChanInsL2Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscDataSigChanInsL2Table." INDEX { mscDataSigChanIndex, mscDataSigChanInsIndex } ::= { mscDataSigChanInsL2Table 1 } MscDataSigChanInsL2Entry ::= SEQUENCE { mscDataSigChanInsT23 Unsigned32, mscDataSigChanInsT200 Unsigned32, mscDataSigChanInsN200 Unsigned32, mscDataSigChanInsT203 Unsigned32, mscDataSigChanInsN201 Unsigned32, mscDataSigChanInsCircuitSwitchedK Unsigned32 } mscDataSigChanInsT23 OBJECT-TYPE SYNTAX Unsigned32 (1..15) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the layer2 enable request timer." DEFVAL { 10 } ::= { mscDataSigChanInsL2Entry 1 } mscDataSigChanInsT200 OBJECT-TYPE SYNTAX Unsigned32 (1..20) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the maximum time between a layer 2 frame and its acknowledgement" DEFVAL { 2 } ::= { mscDataSigChanInsL2Entry 2 } mscDataSigChanInsN200 OBJECT-TYPE SYNTAX Unsigned32 (1..8) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the maximum number of re-transmissions of a layer2 frame." DEFVAL { 3 } ::= { mscDataSigChanInsL2Entry 3 } mscDataSigChanInsT203 OBJECT-TYPE SYNTAX Unsigned32 (2..40) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the maximum time that a no layer 2 traffic situation can last. Expiry triggers a check on whether the far end is a live." DEFVAL { 10 } ::= { mscDataSigChanInsL2Entry 4 } mscDataSigChanInsN201 OBJECT-TYPE SYNTAX Unsigned32 (4..260) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the maximum number of octets in an information field." DEFVAL { 260 } ::= { mscDataSigChanInsL2Entry 5 } mscDataSigChanInsCircuitSwitchedK OBJECT-TYPE SYNTAX Unsigned32 (1..632) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the maximum number of frames for B channel use." DEFVAL { 7 } ::= { mscDataSigChanInsL2Entry 6 } mscDataSigChanInsProvTable OBJECT-TYPE SYNTAX SEQUENCE OF MscDataSigChanInsProvEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This group defines the general options of the d-channel signalling link." ::= { mscDataSigChanIns 13 } mscDataSigChanInsProvEntry OBJECT-TYPE SYNTAX MscDataSigChanInsProvEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscDataSigChanInsProvTable." INDEX { mscDataSigChanIndex, mscDataSigChanInsIndex } ::= { mscDataSigChanInsProvTable 1 } MscDataSigChanInsProvEntry ::= SEQUENCE { mscDataSigChanInsSide INTEGER } mscDataSigChanInsSide OBJECT-TYPE SYNTAX INTEGER { network(1), user(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies whether the layer 2 HDLC interface is the network or user side of the connection." DEFVAL { user } ::= { mscDataSigChanInsProvEntry 1 } mscDataSigChanInsOperTable OBJECT-TYPE SYNTAX SEQUENCE OF MscDataSigChanInsOperEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This group provides the operational attributes for the signalling protocol." ::= { mscDataSigChanIns 15 } mscDataSigChanInsOperEntry OBJECT-TYPE SYNTAX MscDataSigChanInsOperEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscDataSigChanInsOperTable." INDEX { mscDataSigChanIndex, mscDataSigChanInsIndex } ::= { mscDataSigChanInsOperTable 1 } MscDataSigChanInsOperEntry ::= SEQUENCE { mscDataSigChanInsActiveChannels Unsigned32, mscDataSigChanInsPeakActiveChannels Unsigned32, mscDataSigChanInsDChanStatus INTEGER } mscDataSigChanInsActiveChannels OBJECT-TYPE SYNTAX Unsigned32 (0..128) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the number of currently active channels. This includes data and voice channels." DEFVAL { 0 } ::= { mscDataSigChanInsOperEntry 1 } mscDataSigChanInsPeakActiveChannels OBJECT-TYPE SYNTAX Unsigned32 (0..128) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the maximum number of channels that have been active on this signalling channel during the last polling period." DEFVAL { 0 } ::= { mscDataSigChanInsOperEntry 4 } mscDataSigChanInsDChanStatus OBJECT-TYPE SYNTAX INTEGER { outOfService(0), establishing(1), established(2), enabling(3), inService(4), restarting(5) } ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the state of the D-channel. outOfService means that there is no layer 2 or layer 3 connectivity to the PBX. establishing means that the signalling channel is attempting to stage the layer 2. established means that the layer 2 is enabled. If the signalling channel stays in the established state, then it is waiting for a restart from the PBX. enabling means that the resources for processing calls are being initialized. If the signalling channel stays in the enabling state then it is waiting for a restart acknowledgement from the PBX. inService means that the resources for processing calls are available. restarting means that the resources for call processing are being rei- initialized." ::= { mscDataSigChanInsOperEntry 7 } mscDataSigChanInsToolsTable OBJECT-TYPE SYNTAX SEQUENCE OF MscDataSigChanInsToolsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This group contains a series of operational attributes which turn on and off several kinds of tracing." ::= { mscDataSigChanIns 16 } mscDataSigChanInsToolsEntry OBJECT-TYPE SYNTAX MscDataSigChanInsToolsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscDataSigChanInsToolsTable." INDEX { mscDataSigChanIndex, mscDataSigChanInsIndex } ::= { mscDataSigChanInsToolsTable 1 } MscDataSigChanInsToolsEntry ::= SEQUENCE { mscDataSigChanInsTracing OCTET STRING } mscDataSigChanInsTracing OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1)) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute defines which types of tracing are active for this signalling channel. The tracing messages are sent to the debug stream. To see the messages the agentQueue attribute in Col/debug must be greater than 0 and a Telnet NMIS session must list the debug stream in in its data streams (ex. set nmis telnet session/1 dataStreams debug). Different types of tracing can be enabled simultaneously. Note that tracing consumes additional CPU resources and will slow down call processing on a heavily loaded card. If there is message block exhaustion tracing will be suspended for a period and then automatically reenabled. An alarm is generated on tracing suspension and resumption. This mechanism protects the function processor against excessive numbers of tracing messages. Types of tracing include: protocolErrors - get details of any protocol errors which are occuring. Protocol errors are also reported in summary form as alarms. q931Summary - Summary of the Q.931 messages on the signalling link, including certain call details (calling number, called number, release codes). q931Hex - Q.931 messages displayed in hex format. Useful to determine protocol compliance in case of errors reported on local or remote ends. q931Symbolic - Q.931 messages parsed to give maximum detail. Useful for understanding content of messages flowing on the link. portHex - Messages in hex format being sent and received on the link. Description of bits: protocolErrors(0) q931Summary(1) q931Hex(2) q931Symbolic(3) portHex(4)" ::= { mscDataSigChanInsToolsEntry 1 } -- -- DataSigChan/n ts014 Framer -- -- The Framer component controls link layer framing for application -- components sending and receiving data on a link interface. It is also -- through Framer, that an application component is associated with a -- specific hardware link interface. -- -- The Framer component provides provisionable attributes related to -- datapath aspects of the hardware interface (such as crc and frame -- length). The Framer component also provides a provisionable -- attribute which binds the application component to a specific -- hardware component. -- -- The Framer component contains operational attributes for link -- interface datapath statistics (such as frame counts and aborts). -- mscDataSigChanInsFramer OBJECT IDENTIFIER ::= { mscDataSigChanIns 2 } mscDataSigChanInsFramerRowStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF MscDataSigChanInsFramerRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This entry controls the addition and deletion of mscDataSigChanInsFramer components." ::= { mscDataSigChanInsFramer 1 } mscDataSigChanInsFramerRowStatusEntry OBJECT-TYPE SYNTAX MscDataSigChanInsFramerRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A single entry in the table represents a single mscDataSigChanInsFramer component." INDEX { mscDataSigChanIndex, mscDataSigChanInsIndex, mscDataSigChanInsFramerIndex } ::= { mscDataSigChanInsFramerRowStatusTable 1 } MscDataSigChanInsFramerRowStatusEntry ::= SEQUENCE { mscDataSigChanInsFramerRowStatus RowStatus, mscDataSigChanInsFramerComponentName DisplayString, mscDataSigChanInsFramerStorageType StorageType, mscDataSigChanInsFramerIndex NonReplicated } mscDataSigChanInsFramerRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-only STATUS mandatory DESCRIPTION "This variable is used as the basis for SNMP naming of mscDataSigChanInsFramer components. These components cannot be added nor deleted." ::= { mscDataSigChanInsFramerRowStatusEntry 1 } mscDataSigChanInsFramerComponentName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This variable provides the component's string name for use with the ASCII Console Interface" ::= { mscDataSigChanInsFramerRowStatusEntry 2 } mscDataSigChanInsFramerStorageType OBJECT-TYPE SYNTAX StorageType ACCESS read-only STATUS mandatory DESCRIPTION "This variable represents the storage type value for the mscDataSigChanInsFramer tables." ::= { mscDataSigChanInsFramerRowStatusEntry 4 } mscDataSigChanInsFramerIndex OBJECT-TYPE SYNTAX NonReplicated ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable represents the index for the mscDataSigChanInsFramer tables." ::= { mscDataSigChanInsFramerRowStatusEntry 10 } mscDataSigChanInsFramerProvTable OBJECT-TYPE SYNTAX SEQUENCE OF MscDataSigChanInsFramerProvEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This group contains the base provisioning data for the Framer component. Application or hardware interface specific provisioning data is contained in other provisionable Framer groups." ::= { mscDataSigChanInsFramer 10 } mscDataSigChanInsFramerProvEntry OBJECT-TYPE SYNTAX MscDataSigChanInsFramerProvEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscDataSigChanInsFramerProvTable." INDEX { mscDataSigChanIndex, mscDataSigChanInsIndex, mscDataSigChanInsFramerIndex } ::= { mscDataSigChanInsFramerProvTable 1 } MscDataSigChanInsFramerProvEntry ::= SEQUENCE { mscDataSigChanInsFramerInterfaceName Link } mscDataSigChanInsFramerInterfaceName OBJECT-TYPE SYNTAX Link ACCESS read-write STATUS mandatory DESCRIPTION "This attribute contains a hardware component name. The attribute associates the application with a specific link. This defines the module processor on which Framer's parent component (as well as Framer itself) will run." ::= { mscDataSigChanInsFramerProvEntry 1 } mscDataSigChanInsFramerStateTable OBJECT-TYPE SYNTAX SEQUENCE OF MscDataSigChanInsFramerStateEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This group contains the three OSI State attributes. The descriptions generically indicate what each state attribute implies about the component. Note that not all the values and state combinations described here are supported by every component which uses this group. For component-specific information and the valid state combinations, refer to NTP 241-7001-150, Passport Operations and Maintenance Guide." ::= { mscDataSigChanInsFramer 12 } mscDataSigChanInsFramerStateEntry OBJECT-TYPE SYNTAX MscDataSigChanInsFramerStateEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscDataSigChanInsFramerStateTable." INDEX { mscDataSigChanIndex, mscDataSigChanInsIndex, mscDataSigChanInsFramerIndex } ::= { mscDataSigChanInsFramerStateTable 1 } MscDataSigChanInsFramerStateEntry ::= SEQUENCE { mscDataSigChanInsFramerAdminState INTEGER, mscDataSigChanInsFramerOperationalState INTEGER, mscDataSigChanInsFramerUsageState INTEGER } mscDataSigChanInsFramerAdminState OBJECT-TYPE SYNTAX INTEGER { locked(0), unlocked(1), shuttingDown(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the OSI Administrative State of the component. The value locked indicates that the component is administratively prohibited from providing services for its users. A Lock or Lock - force command has been previously issued for this component. When the value is locked, the value of usageState must be idle. The value shuttingDown indicates that the component is administratively permitted to provide service to its existing users only. A Lock command was issued against the component and it is in the process of shutting down. The value unlocked indicates that the component is administratively permitted to provide services for its users. To enter this state, issue an Unlock command to this component." DEFVAL { unlocked } ::= { mscDataSigChanInsFramerStateEntry 1 } mscDataSigChanInsFramerOperationalState OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the OSI Operational State of the component. The value enabled indicates that the component is available for operation. Note that if adminState is locked, it would still not be providing service. The value disabled indicates that the component is not available for operation. For example, something is wrong with the component itself, or with another component on which this one depends. If the value is disabled, the usageState must be idle." DEFVAL { disabled } ::= { mscDataSigChanInsFramerStateEntry 2 } mscDataSigChanInsFramerUsageState OBJECT-TYPE SYNTAX INTEGER { idle(0), active(1), busy(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the OSI Usage State of the component. The value idle indicates that the component is not currently in use. The value active indicates that the component is in use and has spare capacity to provide for additional users. The value busy indicates that the component is in use and has no spare operating capacity for additional users at this time." DEFVAL { idle } ::= { mscDataSigChanInsFramerStateEntry 3 } mscDataSigChanInsFramerStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF MscDataSigChanInsFramerStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This group contains the operational statistics data for a Framer component." ::= { mscDataSigChanInsFramer 13 } mscDataSigChanInsFramerStatsEntry OBJECT-TYPE SYNTAX MscDataSigChanInsFramerStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscDataSigChanInsFramerStatsTable." INDEX { mscDataSigChanIndex, mscDataSigChanInsIndex, mscDataSigChanInsFramerIndex } ::= { mscDataSigChanInsFramerStatsTable 1 } MscDataSigChanInsFramerStatsEntry ::= SEQUENCE { mscDataSigChanInsFramerFrmToIf Unsigned32, mscDataSigChanInsFramerFrmFromIf Unsigned32, mscDataSigChanInsFramerOctetFromIf Unsigned32, mscDataSigChanInsFramerAborts Unsigned32, mscDataSigChanInsFramerCrcErrors Unsigned32, mscDataSigChanInsFramerLrcErrors Unsigned32, mscDataSigChanInsFramerNonOctetErrors Unsigned32, mscDataSigChanInsFramerOverruns Unsigned32, mscDataSigChanInsFramerUnderruns Unsigned32, mscDataSigChanInsFramerLargeFrmErrors Unsigned32 } mscDataSigChanInsFramerFrmToIf OBJECT-TYPE SYNTAX Unsigned32 (0..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute counts the number of frames transmitted to the link interface by Framer. This count wraps to zero after reaching its maximum value." DEFVAL { 0 } ::= { mscDataSigChanInsFramerStatsEntry 1 } mscDataSigChanInsFramerFrmFromIf OBJECT-TYPE SYNTAX Unsigned32 (0..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute counts the number of frames received from the link interface by Framer. This count wraps to zero after reaching its maximum value." DEFVAL { 0 } ::= { mscDataSigChanInsFramerStatsEntry 2 } mscDataSigChanInsFramerOctetFromIf OBJECT-TYPE SYNTAX Unsigned32 (0..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "The number of bytes received from the link interface by Framer." DEFVAL { 0 } ::= { mscDataSigChanInsFramerStatsEntry 3 } mscDataSigChanInsFramerAborts OBJECT-TYPE SYNTAX Unsigned32 (0..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute counts the total number of aborts received. This count wraps to zero after reaching its maximum value." DEFVAL { 0 } ::= { mscDataSigChanInsFramerStatsEntry 4 } mscDataSigChanInsFramerCrcErrors OBJECT-TYPE SYNTAX Unsigned32 (0..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute counts the total number of frames with CRC errors. This count wraps to zero after reaching its maximum value." DEFVAL { 0 } ::= { mscDataSigChanInsFramerStatsEntry 5 } mscDataSigChanInsFramerLrcErrors OBJECT-TYPE SYNTAX Unsigned32 (0..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute counts the total number of frames with LRC errors. This count wraps to zero after reaching its maximum value." DEFVAL { 0 } ::= { mscDataSigChanInsFramerStatsEntry 6 } mscDataSigChanInsFramerNonOctetErrors OBJECT-TYPE SYNTAX Unsigned32 (0..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute counts the total number of frames that were non octet aligned. This count wraps to zero after reaching its maximum value." DEFVAL { 0 } ::= { mscDataSigChanInsFramerStatsEntry 7 } mscDataSigChanInsFramerOverruns OBJECT-TYPE SYNTAX Unsigned32 (0..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute counts the total number of frames received from the link for which overruns occurred. This count wraps to zero after reaching its maximum value." DEFVAL { 0 } ::= { mscDataSigChanInsFramerStatsEntry 8 } mscDataSigChanInsFramerUnderruns OBJECT-TYPE SYNTAX Unsigned32 (0..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute counts the total number of frames transmitted to the link for which underruns occurred. This count wraps to zero after reaching its maximum value." DEFVAL { 0 } ::= { mscDataSigChanInsFramerStatsEntry 9 } mscDataSigChanInsFramerLargeFrmErrors OBJECT-TYPE SYNTAX Unsigned32 (0..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute counts the total number of frames received which were too large. The frame was longer than 500 bytes. This count wraps to zero after reaching its maximum value." DEFVAL { 0 } ::= { mscDataSigChanInsFramerStatsEntry 10 } -- -- Version and Compliance statements -- -- Object-Group Statement: -- A list of all current accessible leaf objects. -- OBJECTS { mscDataSigChanInsRowStatus, -- mscDataSigChanInsN201, -- mscDataSigChanInsFramerFrmToIf, -- mscDataSigChanInsFramerNonOctetErrors, -- mscDataSigChanInsPeakActiveChannels, -- mscDataSigChanInsFramerUsageState, -- mscDataSigChanInsFramerComponentName, -- mscDataSigChanInsN200, -- mscDataSigChanInsSide, -- mscDataSigChanInsFramerFrmFromIf, -- mscDataSigChanInsFramerInterfaceName, -- mscDataSigChanInsFramerStorageType, -- mscDataSigChanInsCircuitSwitchedK, -- mscDataSigChanInsFramerUnderruns, -- mscDataSigChanInsComponentName, -- mscDataSigChanInsFramerCrcErrors, -- mscDataSigChanInsStorageType, -- mscDataSigChanInsFramerOperationalState, -- mscDataSigChanInsT200, -- mscDataSigChanInsActiveChannels, -- mscDataSigChanInsFramerOctetFromIf, -- mscDataSigChanInsT203, -- mscDataSigChanInsDChanStatus, -- mscDataSigChanInsFramerAdminState, -- mscDataSigChanInsT23, -- mscDataSigChanInsFramerLrcErrors, -- mscDataSigChanInsFramerLargeFrmErrors, -- mscDataSigChanInsFramerOverruns, -- mscDataSigChanInsFramerRowStatus, -- mscDataSigChanInsTracing, -- mscDataSigChanInsFramerAborts } -- STATUS mandatory -- DESCRIPTION -- "A list of all current accessible leaf objects." disdnJapanInsGroup OBJECT IDENTIFIER ::= { disdnJapanInsMIB 1 } disdnJapanInsGroupCA OBJECT IDENTIFIER ::= { disdnJapanInsGroup 1 } disdnJapanInsGroupCA02 OBJECT IDENTIFIER ::= { disdnJapanInsGroupCA 3 } disdnJapanInsGroupCA02A OBJECT IDENTIFIER ::= { disdnJapanInsGroupCA02 2 } -- Agent-Capabilities Statement: -- PRODUCT-RELEASE "MscPassport Release 1.2 DisdnJapanIns." -- STATUS mandatory -- DESCRIPTION "Carrier Passport DisdnJapanIns MIB: MIB Version CA02A, -- Software Version CA02S9C." -- SUPPORTS Nortel-MsCarrier-MscPassport-DisdnJapanInsMIB -- INCLUDES { disdnJapanInsGroupCA02A } disdnJapanInsCapabilities OBJECT IDENTIFIER ::= { disdnJapanInsMIB 3 } disdnJapanInsCapabilitiesCA OBJECT IDENTIFIER ::= { disdnJapanInsCapabilities 1 } disdnJapanInsCapabilitiesCA02 OBJECT IDENTIFIER ::= { disdnJapanInsCapabilitiesCA 3 } disdnJapanInsCapabilitiesCA02A OBJECT IDENTIFIER ::= { disdnJapanInsCapabilitiesCA02 2 } END