Nortel-MsCarrier-MscPassport-AtmNetworkingMIB DEFINITIONS ::= BEGIN IMPORTS OBJECT-TYPE FROM RFC-1212 mscPassportMIBs, mscComponents FROM Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB Counter32, RowPointer, DisplayString, StorageType, RowStatus, Gauge32, Integer32, Unsigned32 FROM Nortel-MsCarrier-MscPassport-StandardTextualConventionsMIB AsciiString, NonReplicated, HexString, FixedPoint1, AsciiStringIndex, IntegerSequence FROM Nortel-MsCarrier-MscPassport-TextualConventionsMIB mscAtmIfVptVcc, mscAtmIfVccIndex, mscAtmIfVptIndex, mscAtmIfVcc, mscAtmIfVpcIndex, mscAtmIfVpc, mscAtmIfVptVccIndex, mscAtmIfIndex FROM Nortel-MsCarrier-MscPassport-AtmCoreMIB; -- LAST-UPDATED "9909010000Z" -- ORGANIZATION "Nortel Networks" -- CONTACT-INFO " -- Nortel Carrier Data Network Management -- -- Postal: P.O. Box 3511, Station C -- Ottawa, Ontario -- Canada K1Y 4H7 -- -- via the WEB: http://www.nortelnetworks.com -- select 'Contact Us' from the menu -- -- via phone: 1-800-4NORTEL" -- DESCRIPTION -- "The module describing the Nortel MsCarrier MscPassport -- AtmNetworking Enterprise MIB." atmNetworkingMIB OBJECT IDENTIFIER ::= { mscPassportMIBs 42 } -- AtmRouting -- This component contains the provisionable and operational -- attributes related to ATM PNNI routing. -- -- The Dna subcomponents can be listed to view all the provisioned -- and registered ATM end system addresses and prefixes stored -- against any of the Uni, Iisp or Pnni interfaces. -- -- The Pnni subcomponent can be provisioned to identify that this -- Passport node participates in a PNNI hierarchy. -- -- The ConfiguredNode subcomponents are indexed by level in the -- PNNI hierarchy (a value between 0 and 104), and define -- configuration information. mscARtg OBJECT IDENTIFIER ::= { mscComponents 95 } mscARtgRowStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF MscARtgRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This entry controls the addition and deletion of mscARtg components." ::= { mscARtg 1 } mscARtgRowStatusEntry OBJECT-TYPE SYNTAX MscARtgRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A single entry in the table represents a single mscARtg component." INDEX { mscARtgIndex } ::= { mscARtgRowStatusTable 1 } MscARtgRowStatusEntry ::= SEQUENCE { mscARtgRowStatus RowStatus, mscARtgComponentName DisplayString, mscARtgStorageType StorageType, mscARtgIndex NonReplicated } mscARtgRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-write STATUS mandatory DESCRIPTION "This variable is used as the basis for SNMP naming of mscARtg components. These components can be added and deleted." ::= { mscARtgRowStatusEntry 1 } mscARtgComponentName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This variable provides the component's string name for use with the ASCII Console Interface" ::= { mscARtgRowStatusEntry 2 } mscARtgStorageType OBJECT-TYPE SYNTAX StorageType ACCESS read-only STATUS mandatory DESCRIPTION "This variable represents the storage type value for the mscARtg tables." ::= { mscARtgRowStatusEntry 4 } mscARtgIndex OBJECT-TYPE SYNTAX NonReplicated ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable represents the index for the mscARtg tables." ::= { mscARtgRowStatusEntry 10 } mscARtgStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF MscARtgStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This group contains the statistical operational attributes of an ARtg component." ::= { mscARtg 10 } mscARtgStatsEntry OBJECT-TYPE SYNTAX MscARtgStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscARtgStatsTable." INDEX { mscARtgIndex } ::= { mscARtgStatsTable 1 } MscARtgStatsEntry ::= SEQUENCE { mscARtgRoutingAttempts Counter32, mscARtgFailedRoutingAttempts Counter32 } mscARtgRoutingAttempts OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS mandatory DESCRIPTION "This attribute counts the total number of calls routed. The counter wraps when it exceeds the maximum value." ::= { mscARtgStatsEntry 1 } mscARtgFailedRoutingAttempts OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS mandatory DESCRIPTION "This attribute counts the total number of calls which were not successfully routed.The counter wraps when it exceeds the maximum value." ::= { mscARtgStatsEntry 2 } -- -- *** THIS SUBTREE CURRENTLY NOT IMPLEMENTED *** -- -- ARtg Dna/ -- This component represents an ATM NSAP address that has been -- provisioned or dynamically registered through ILMI. mscARtgDna OBJECT IDENTIFIER ::= { mscARtg 2 } mscARtgDnaRowStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF MscARtgDnaRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "*** THIS TABLE CURRENTLY NOT IMPLEMENTED *** This entry controls the addition and deletion of mscARtgDna components." ::= { mscARtgDna 1 } mscARtgDnaRowStatusEntry OBJECT-TYPE SYNTAX MscARtgDnaRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A single entry in the table represents a single mscARtgDna component." INDEX { mscARtgIndex, mscARtgDnaIndex } ::= { mscARtgDnaRowStatusTable 1 } MscARtgDnaRowStatusEntry ::= SEQUENCE { mscARtgDnaRowStatus RowStatus, mscARtgDnaComponentName DisplayString, mscARtgDnaStorageType StorageType, mscARtgDnaIndex AsciiStringIndex } mscARtgDnaRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-only STATUS mandatory DESCRIPTION "This variable is used as the basis for SNMP naming of mscARtgDna components. These components cannot be added nor deleted." ::= { mscARtgDnaRowStatusEntry 1 } mscARtgDnaComponentName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This variable provides the component's string name for use with the ASCII Console Interface" ::= { mscARtgDnaRowStatusEntry 2 } mscARtgDnaStorageType OBJECT-TYPE SYNTAX StorageType ACCESS read-only STATUS mandatory DESCRIPTION "This variable represents the storage type value for the mscARtgDna tables." ::= { mscARtgDnaRowStatusEntry 4 } mscARtgDnaIndex OBJECT-TYPE SYNTAX AsciiStringIndex (SIZE (1..40)) ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable represents the index for the mscARtgDna tables." ::= { mscARtgDnaRowStatusEntry 10 } -- -- *** THIS SUBTREE CURRENTLY NOT IMPLEMENTED *** -- -- ARtg Dna/ DestInfo/ -- This component represents a destination associated with the parent -- Dna. mscARtgDnaDestInfo OBJECT IDENTIFIER ::= { mscARtgDna 2 } mscARtgDnaDestInfoRowStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF MscARtgDnaDestInfoRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "*** THIS TABLE CURRENTLY NOT IMPLEMENTED *** This entry controls the addition and deletion of mscARtgDnaDestInfo components." ::= { mscARtgDnaDestInfo 1 } mscARtgDnaDestInfoRowStatusEntry OBJECT-TYPE SYNTAX MscARtgDnaDestInfoRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A single entry in the table represents a single mscARtgDnaDestInfo component." INDEX { mscARtgIndex, mscARtgDnaIndex, mscARtgDnaDestInfoIndex } ::= { mscARtgDnaDestInfoRowStatusTable 1 } MscARtgDnaDestInfoRowStatusEntry ::= SEQUENCE { mscARtgDnaDestInfoRowStatus RowStatus, mscARtgDnaDestInfoComponentName DisplayString, mscARtgDnaDestInfoStorageType StorageType, mscARtgDnaDestInfoIndex Integer32 } mscARtgDnaDestInfoRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-only STATUS mandatory DESCRIPTION "This variable is used as the basis for SNMP naming of mscARtgDnaDestInfo components. These components cannot be added nor deleted." ::= { mscARtgDnaDestInfoRowStatusEntry 1 } mscARtgDnaDestInfoComponentName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This variable provides the component's string name for use with the ASCII Console Interface" ::= { mscARtgDnaDestInfoRowStatusEntry 2 } mscARtgDnaDestInfoStorageType OBJECT-TYPE SYNTAX StorageType ACCESS read-only STATUS mandatory DESCRIPTION "This variable represents the storage type value for the mscARtgDnaDestInfo tables." ::= { mscARtgDnaDestInfoRowStatusEntry 4 } mscARtgDnaDestInfoIndex OBJECT-TYPE SYNTAX Integer32 (0..50) ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable represents the index for the mscARtgDnaDestInfo tables." ::= { mscARtgDnaDestInfoRowStatusEntry 10 } mscARtgDnaDestInfoOperTable OBJECT-TYPE SYNTAX SEQUENCE OF MscARtgDnaDestInfoOperEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "*** THIS TABLE CURRENTLY NOT IMPLEMENTED *** This group contains the operational attributes for the DestInfo component." ::= { mscARtgDnaDestInfo 10 } mscARtgDnaDestInfoOperEntry OBJECT-TYPE SYNTAX MscARtgDnaDestInfoOperEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscARtgDnaDestInfoOperTable." INDEX { mscARtgIndex, mscARtgDnaIndex, mscARtgDnaDestInfoIndex } ::= { mscARtgDnaDestInfoOperTable 1 } MscARtgDnaDestInfoOperEntry ::= SEQUENCE { mscARtgDnaDestInfoType INTEGER, mscARtgDnaDestInfoScope INTEGER, mscARtgDnaDestInfoStdComponentName RowPointer, mscARtgDnaDestInfoReachability INTEGER } mscARtgDnaDestInfoType OBJECT-TYPE SYNTAX INTEGER { primary(0), alternate(1), registered(2), default(3), ebr(4) } ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the type of the address at the destination interface. Provisioned addresses are assigned a type of primary or alternate; ATM routing will try primary routes and then the alternate routes if none of the primary routes succeed. The type registered is used for dynamic addresses registered through ILMI. The type default is used for Soft PVC addresses. The type ebr indicates addresses used by Edge Based Rerouting." ::= { mscARtgDnaDestInfoOperEntry 1 } mscARtgDnaDestInfoScope OBJECT-TYPE SYNTAX INTEGER (-1..104) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the highest level (meaning the lowest level number) in the hierarchy that the address will be advertised to. A value of -1 indicates that the scope is not applicable since this node has not been configured as a PNNI node." ::= { mscARtgDnaDestInfoOperEntry 2 } mscARtgDnaDestInfoStdComponentName OBJECT-TYPE SYNTAX RowPointer ACCESS read-only STATUS mandatory DESCRIPTION "This attribute represents a component name of the interface through which the address can be reached." ::= { mscARtgDnaDestInfoOperEntry 3 } mscARtgDnaDestInfoReachability OBJECT-TYPE SYNTAX INTEGER { internal(0), exterior(1) } ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates whether the address is internal or exterior." ::= { mscARtgDnaDestInfoOperEntry 4 } -- ARtg Pnni -- This component contains the provisionable and operational -- attributes for a PNNI node. Provisioning the Pnni component under -- the ARtg component indicates that this switch has PNNI routing -- capability. -- The Pnni component must have one and only one ConfiguredNode -- subcomponent. mscARtgPnni OBJECT IDENTIFIER ::= { mscARtg 3 } mscARtgPnniRowStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF MscARtgPnniRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This entry controls the addition and deletion of mscARtgPnni components." ::= { mscARtgPnni 1 } mscARtgPnniRowStatusEntry OBJECT-TYPE SYNTAX MscARtgPnniRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A single entry in the table represents a single mscARtgPnni component." INDEX { mscARtgIndex, mscARtgPnniIndex } ::= { mscARtgPnniRowStatusTable 1 } MscARtgPnniRowStatusEntry ::= SEQUENCE { mscARtgPnniRowStatus RowStatus, mscARtgPnniComponentName DisplayString, mscARtgPnniStorageType StorageType, mscARtgPnniIndex NonReplicated } mscARtgPnniRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-write STATUS mandatory DESCRIPTION "This variable is used as the basis for SNMP naming of mscARtgPnni components. These components can be added and deleted." ::= { mscARtgPnniRowStatusEntry 1 } mscARtgPnniComponentName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This variable provides the component's string name for use with the ASCII Console Interface" ::= { mscARtgPnniRowStatusEntry 2 } mscARtgPnniStorageType OBJECT-TYPE SYNTAX StorageType ACCESS read-only STATUS mandatory DESCRIPTION "This variable represents the storage type value for the mscARtgPnni tables." ::= { mscARtgPnniRowStatusEntry 4 } mscARtgPnniIndex OBJECT-TYPE SYNTAX NonReplicated ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable represents the index for the mscARtgPnni tables." ::= { mscARtgPnniRowStatusEntry 10 } mscARtgPnniProvTable OBJECT-TYPE SYNTAX SEQUENCE OF MscARtgPnniProvEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This group contains the generic provisionable attributes of a Pnni component." ::= { mscARtgPnni 10 } mscARtgPnniProvEntry OBJECT-TYPE SYNTAX MscARtgPnniProvEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscARtgPnniProvTable." INDEX { mscARtgIndex, mscARtgPnniIndex } ::= { mscARtgPnniProvTable 1 } MscARtgPnniProvEntry ::= SEQUENCE { mscARtgPnniNodeAddressPrefix HexString, mscARtgPnniDefaultScope Unsigned32, mscARtgPnniDomain AsciiString, mscARtgPnniRestrictTransit INTEGER, mscARtgPnniMaxAlternateRoutesOnCrankback Unsigned32 } mscARtgPnniNodeAddressPrefix OBJECT-TYPE SYNTAX HexString (SIZE (0..19)) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the ATM address of this node. It allows the default node address to be overridden. If this attribute is set to the null string, then the default node address prefix is assumed, and computed as follows: the value provisioned for the ModuleData component's nodePrefix attribute, followed by a unique MAC address (6 octets)." ::= { mscARtgPnniProvEntry 1 } mscARtgPnniDefaultScope OBJECT-TYPE SYNTAX Unsigned32 (0..104) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the default PNNI scope for ATM addresses associated with this node. The PNNI scope determines the level to which the address will be advertised within the PNNI routing domain. A provisioned Addr component may override the default scope in a PnniInfo subcomponent. A value of 0 means that all addresses which do not have provisioned scopes will be advertised globally within the PNNI routing domain. The value specified must be numerically smaller than or equal to that of the lowest level at which this node is configured in the PNNI hierarchy." DEFVAL { 0 } ::= { mscARtgPnniProvEntry 2 } mscARtgPnniDomain OBJECT-TYPE SYNTAX AsciiString (SIZE (1..32)) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the routing domain name. This attribute should be set identically for all nodes in the same routing domain." DEFVAL { '31'H } -- "1" ::= { mscARtgPnniProvEntry 3 } mscARtgPnniRestrictTransit OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies if the node should restrict tandeming of SVCs. If this attribute is set to true, then other lowest level nodes in the PNNI hierarchy will avoid traversing this node during route computation." DEFVAL { false } ::= { mscARtgPnniProvEntry 4 } mscARtgPnniMaxAlternateRoutesOnCrankback OBJECT-TYPE SYNTAX Unsigned32 (0..20) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the number of alternate routing attempts before a call requiring crank back is rejected." DEFVAL { 1 } ::= { mscARtgPnniProvEntry 5 } mscARtgPnniPglParmsTable OBJECT-TYPE SYNTAX SEQUENCE OF MscARtgPnniPglParmsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This group contains the provisionable attributes for the peer group leader election timer parameters of a Pnni component." ::= { mscARtgPnni 11 } mscARtgPnniPglParmsEntry OBJECT-TYPE SYNTAX MscARtgPnniPglParmsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscARtgPnniPglParmsTable." INDEX { mscARtgIndex, mscARtgPnniIndex } ::= { mscARtgPnniPglParmsTable 1 } MscARtgPnniPglParmsEntry ::= SEQUENCE { mscARtgPnniPglInitTime Unsigned32, mscARtgPnniOverrideDelay Unsigned32, mscARtgPnniReElectionInterval Unsigned32 } mscARtgPnniPglInitTime OBJECT-TYPE SYNTAX Unsigned32 (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies how long this node will delay advertising its choice of preferred peer group leader after having initialized operation and reached the full peer state with at least one neighbor in the peer group." DEFVAL { 15 } ::= { mscARtgPnniPglParmsEntry 1 } mscARtgPnniOverrideDelay OBJECT-TYPE SYNTAX Unsigned32 (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies how long a node will wait for itself to be declared the preferred peer group leader by unanimous agreement among its peers." DEFVAL { 30 } ::= { mscARtgPnniPglParmsEntry 2 } mscARtgPnniReElectionInterval OBJECT-TYPE SYNTAX Unsigned32 (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies how long this node will wait after losing connectivity to the current peer group leader before re-starting the process of electing a new peer group leader." DEFVAL { 15 } ::= { mscARtgPnniPglParmsEntry 3 } mscARtgPnniHlParmsTable OBJECT-TYPE SYNTAX SEQUENCE OF MscARtgPnniHlParmsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This group contains the default provisionable Hello protocol parameters." ::= { mscARtgPnni 12 } mscARtgPnniHlParmsEntry OBJECT-TYPE SYNTAX MscARtgPnniHlParmsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscARtgPnniHlParmsTable." INDEX { mscARtgIndex, mscARtgPnniIndex } ::= { mscARtgPnniHlParmsTable 1 } MscARtgPnniHlParmsEntry ::= SEQUENCE { mscARtgPnniHelloHoldDown FixedPoint1, mscARtgPnniHelloInterval Unsigned32, mscARtgPnniHelloInactivityFactor Unsigned32 } mscARtgPnniHelloHoldDown OBJECT-TYPE SYNTAX FixedPoint1 (1..655350) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute is used to limit the rate at which this node sends out Hello packets. Specifically, it specifies the default minimum amount of time between successive Hellos used by routing control channels on this node." DEFVAL { 10 } ::= { mscARtgPnniHlParmsEntry 1 } mscARtgPnniHelloInterval OBJECT-TYPE SYNTAX Unsigned32 (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the default duration of the Hello Timer in seconds for routing control channels on this node. Every helloInterval seconds, this node will send out a Hello packet to the neighbor node, subject to the helloHoldDown timer having expired at least once since the last Hello packet was sent." DEFVAL { 15 } ::= { mscARtgPnniHlParmsEntry 2 } mscARtgPnniHelloInactivityFactor OBJECT-TYPE SYNTAX Unsigned32 (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the default number of Hello intervals allowed to pass without receiving a Hello from the neighbor node, before an attempt is made to re-stage, for routing control channels on this node. The hello inactivity timer is enabled in the oneWayInside, twoWayInside, oneWayOutside, twoWayOutside and commonOutside (see the helloState attribute on the Rcc component for a description of these states). Note that the value for the Hello interval used in the calculation is the one specified in the Hello packet from the neighbor node." DEFVAL { 5 } ::= { mscARtgPnniHlParmsEntry 3 } mscARtgPnniPtseParmsTable OBJECT-TYPE SYNTAX SEQUENCE OF MscARtgPnniPtseParmsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This group contains the provisionable attributes for the PTSE timer values of a Pnni component." ::= { mscARtgPnni 13 } mscARtgPnniPtseParmsEntry OBJECT-TYPE SYNTAX MscARtgPnniPtseParmsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscARtgPnniPtseParmsTable." INDEX { mscARtgIndex, mscARtgPnniIndex } ::= { mscARtgPnniPtseParmsTable 1 } MscARtgPnniPtseParmsEntry ::= SEQUENCE { mscARtgPnniPtseHoldDown FixedPoint1, mscARtgPnniPtseRefreshInterval Unsigned32, mscARtgPnniPtseLifetimeFactor Unsigned32, mscARtgPnniRequestRxmtInterval Unsigned32, mscARtgPnniPeerDelayedAckInterval FixedPoint1 } mscARtgPnniPtseHoldDown OBJECT-TYPE SYNTAX FixedPoint1 (1..655350) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute is used to limit the rate at which this node sends out PTSE packets. Specifically, it specifies the minimum amount of time in seconds that this node must wait between sending successive PTSE packets." DEFVAL { 10 } ::= { mscARtgPnniPtseParmsEntry 1 } mscARtgPnniPtseRefreshInterval OBJECT-TYPE SYNTAX Unsigned32 (300..65535) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the duration of the PTSE Timer. Every ptseRefreshInterval seconds, this node will send out a self- originated PTSE packet to the neighbor node, subject to the ptseHoldDown timer having expired at least once since the last PTSE packet was sent." DEFVAL { 1800 } ::= { mscARtgPnniPtseParmsEntry 2 } mscARtgPnniPtseLifetimeFactor OBJECT-TYPE SYNTAX Unsigned32 (101..1000) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the lifetime multiplier. The result of multiplying the ptseRefreshInterval by this value is used as the initial lifetime that this node places into PTSEs." DEFVAL { 200 } ::= { mscARtgPnniPtseParmsEntry 3 } mscARtgPnniRequestRxmtInterval OBJECT-TYPE SYNTAX Unsigned32 (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the period between retransmissions of unacknowledged Database Summary packets, PTSE Request packets and PTSPs." DEFVAL { 5 } ::= { mscARtgPnniPtseParmsEntry 4 } mscARtgPnniPeerDelayedAckInterval OBJECT-TYPE SYNTAX FixedPoint1 (1..655350) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the minimum amount of time between transmissions of delayed PTSE acknowledgment packets." DEFVAL { 1 } ::= { mscARtgPnniPtseParmsEntry 5 } mscARtgPnniThreshParmsTable OBJECT-TYPE SYNTAX SEQUENCE OF MscARtgPnniThreshParmsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This group contains the provisionable attributes for the change thresholds of a ARtg Pnni component." ::= { mscARtgPnni 14 } mscARtgPnniThreshParmsEntry OBJECT-TYPE SYNTAX MscARtgPnniThreshParmsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscARtgPnniThreshParmsTable." INDEX { mscARtgIndex, mscARtgPnniIndex } ::= { mscARtgPnniThreshParmsTable 1 } MscARtgPnniThreshParmsEntry ::= SEQUENCE { mscARtgPnniAvcrMt Unsigned32, mscARtgPnniAvcrPm Unsigned32 } mscARtgPnniAvcrMt OBJECT-TYPE SYNTAX Unsigned32 (1..99) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute when multiplied by the Maximum Cell Rate specifies the minimum threshold used in the algorithms that determine significant change for average cell rate parameters." DEFVAL { 3 } ::= { mscARtgPnniThreshParmsEntry 1 } mscARtgPnniAvcrPm OBJECT-TYPE SYNTAX Unsigned32 (1..99) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute when multiplied by the current Available Cell Rate specifies the threshold used in the algorithms that determine significant change for AvCR parameters. If the resulting threshold is lower than minimum threshold, minimum threshold will be used. Increasing the value of the attribute increases the range of insignificance and reduces the amount of PTSP flooding due to changes in resource availability." DEFVAL { 50 } ::= { mscARtgPnniThreshParmsEntry 2 } mscARtgPnniOperTable OBJECT-TYPE SYNTAX SEQUENCE OF MscARtgPnniOperEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This group contains the generic operational attributes of an ARtg Pnni component." ::= { mscARtgPnni 15 } mscARtgPnniOperEntry OBJECT-TYPE SYNTAX MscARtgPnniOperEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscARtgPnniOperTable." INDEX { mscARtgIndex, mscARtgPnniIndex } ::= { mscARtgPnniOperTable 1 } MscARtgPnniOperEntry ::= SEQUENCE { mscARtgPnniTopologyMemoryExhaustion INTEGER } mscARtgPnniTopologyMemoryExhaustion OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates if the topology database is overloaded. A node goes into a database overload state when it fails to store the complete topology database due to insufficient memory in the node. A node in this state performs resynchronization periodically by restarting all its Neighbor Peer Finite State Machines. The node will stay in this state until it synchronizes with all of its neighbors without any overload problems. When this attribute is set an alarm will be issued." ::= { mscARtgPnniOperEntry 2 } mscARtgPnniStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF MscARtgPnniStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This group contains the statistical operational attributes of a ARtg Pnni component." ::= { mscARtgPnni 16 } mscARtgPnniStatsEntry OBJECT-TYPE SYNTAX MscARtgPnniStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscARtgPnniStatsTable." INDEX { mscARtgIndex, mscARtgPnniIndex } ::= { mscARtgPnniStatsTable 1 } MscARtgPnniStatsEntry ::= SEQUENCE { mscARtgPnniSuccessfulRoutingAttempts Counter32, mscARtgPnniFailedRoutingAttempts Counter32, mscARtgPnniAlternateRoutingAttempts Counter32 } mscARtgPnniSuccessfulRoutingAttempts OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS mandatory DESCRIPTION "This attribute counts successful PNNI routing attempts. The counter wraps when it exceeds the maximum value." ::= { mscARtgPnniStatsEntry 1 } mscARtgPnniFailedRoutingAttempts OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS mandatory DESCRIPTION "This attribute counts failed PNNI routing attempts. The counter wraps when it exceeds the maximum value." ::= { mscARtgPnniStatsEntry 2 } mscARtgPnniAlternateRoutingAttempts OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS mandatory DESCRIPTION "This attribute counts successful PNNI alternate routing attempts. The counter wraps when it exceeds the maximum value." ::= { mscARtgPnniStatsEntry 3 } mscARtgPnniOptMetricTable OBJECT-TYPE SYNTAX SEQUENCE OF MscARtgPnniOptMetricEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This attribute is a vector that specifies the optimization metric for each ATM service category. The optimization metric is used during Generic Connection Admission Control (GCAC) route computation. Setting the value to cdv for a particular service category will cause GCAC to optimize for cell delay variation on call setups requiring that service category. Setting the value to maxCtd for a particular service category will cause GCAC to optimize for maximum cell transfer delay on call setups requiring that service category. Setting the value to aw for a particular service category will cause GCAC to optimize for administrative weight on call setups requiring that service category." ::= { mscARtgPnni 386 } mscARtgPnniOptMetricEntry OBJECT-TYPE SYNTAX MscARtgPnniOptMetricEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscARtgPnniOptMetricTable." INDEX { mscARtgIndex, mscARtgPnniIndex, mscARtgPnniOptMetricIndex } ::= { mscARtgPnniOptMetricTable 1 } MscARtgPnniOptMetricEntry ::= SEQUENCE { mscARtgPnniOptMetricIndex INTEGER, mscARtgPnniOptMetricValue INTEGER } mscARtgPnniOptMetricIndex OBJECT-TYPE SYNTAX INTEGER { cbr(1), rtVbr(2), nrtVbr(3), ubr(4) } ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable represents the mscARtgPnniOptMetricTable specific index for the mscARtgPnniOptMetricTable." ::= { mscARtgPnniOptMetricEntry 1 } mscARtgPnniOptMetricValue OBJECT-TYPE SYNTAX INTEGER { cdv(0), maxCtd(1), aw(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This variable represents an individual value for the mscARtgPnniOptMetricTable." ::= { mscARtgPnniOptMetricEntry 2 } -- ARtg Pnni RouteFinder -- This component is used to compute a list of routes to a specified -- destination which satisfy certain traffic and routing requirements. -- -- To display a list of computed routes: -- - set the route computation criteria -- - issue the Run command mscARtgPnniRf OBJECT IDENTIFIER ::= { mscARtgPnni 2 } mscARtgPnniRfRowStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF MscARtgPnniRfRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This entry controls the addition and deletion of mscARtgPnniRf components." ::= { mscARtgPnniRf 1 } mscARtgPnniRfRowStatusEntry OBJECT-TYPE SYNTAX MscARtgPnniRfRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A single entry in the table represents a single mscARtgPnniRf component." INDEX { mscARtgIndex, mscARtgPnniIndex, mscARtgPnniRfIndex } ::= { mscARtgPnniRfRowStatusTable 1 } MscARtgPnniRfRowStatusEntry ::= SEQUENCE { mscARtgPnniRfRowStatus RowStatus, mscARtgPnniRfComponentName DisplayString, mscARtgPnniRfStorageType StorageType, mscARtgPnniRfIndex NonReplicated } mscARtgPnniRfRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-only STATUS mandatory DESCRIPTION "This variable is used as the basis for SNMP naming of mscARtgPnniRf components. These components cannot be added nor deleted." ::= { mscARtgPnniRfRowStatusEntry 1 } mscARtgPnniRfComponentName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This variable provides the component's string name for use with the ASCII Console Interface" ::= { mscARtgPnniRfRowStatusEntry 2 } mscARtgPnniRfStorageType OBJECT-TYPE SYNTAX StorageType ACCESS read-only STATUS mandatory DESCRIPTION "This variable represents the storage type value for the mscARtgPnniRf tables." ::= { mscARtgPnniRfRowStatusEntry 4 } mscARtgPnniRfIndex OBJECT-TYPE SYNTAX NonReplicated ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable represents the index for the mscARtgPnniRf tables." ::= { mscARtgPnniRfRowStatusEntry 10 } mscARtgPnniRfCriteriaTable OBJECT-TYPE SYNTAX SEQUENCE OF MscARtgPnniRfCriteriaEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This group contains the attributes specifying the routing criteria for the route computation." ::= { mscARtgPnniRf 10 } mscARtgPnniRfCriteriaEntry OBJECT-TYPE SYNTAX MscARtgPnniRfCriteriaEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscARtgPnniRfCriteriaTable." INDEX { mscARtgIndex, mscARtgPnniIndex, mscARtgPnniRfIndex } ::= { mscARtgPnniRfCriteriaTable 1 } MscARtgPnniRfCriteriaEntry ::= SEQUENCE { mscARtgPnniRfDestinationAddress HexString, mscARtgPnniRfMaxRoutes Unsigned32, mscARtgPnniRfTxTrafficDescType INTEGER, mscARtgPnniRfRxTrafficDescType INTEGER, mscARtgPnniRfAtmServiceCategory INTEGER, mscARtgPnniRfFwdQosClass INTEGER, mscARtgPnniRfBwdQosClass INTEGER, mscARtgPnniRfBearerClassBbc INTEGER, mscARtgPnniRfTransferCapabilityBbc INTEGER, mscARtgPnniRfClippingBbc INTEGER, mscARtgPnniRfBestEffort INTEGER, mscARtgPnniRfOptimizationMetric INTEGER } mscARtgPnniRfDestinationAddress OBJECT-TYPE SYNTAX HexString (SIZE (1..20)) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the destination NSAP address to be used for the computation. If this attribute specifies an invalid address then no routes will be found." ::= { mscARtgPnniRfCriteriaEntry 1 } mscARtgPnniRfMaxRoutes OBJECT-TYPE SYNTAX Unsigned32 (1..15) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies a ceiling on the number of routes to be computed." DEFVAL { 1 } ::= { mscARtgPnniRfCriteriaEntry 2 } mscARtgPnniRfTxTrafficDescType OBJECT-TYPE SYNTAX INTEGER { n1(1), n2(2), n3(3), n4(4), n5(5), n6(6), n7(7), n8(8) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the type of traffic management which is applied to the transmit direction as defined in the ATM Forum. The txTrafficDescType determines the number and meaning of the parameters in the txTrafficDescParm attribute." DEFVAL { n1 } ::= { mscARtgPnniRfCriteriaEntry 3 } mscARtgPnniRfRxTrafficDescType OBJECT-TYPE SYNTAX INTEGER { n1(1), n2(2), n3(3), n4(4), n5(5), n6(6), n7(7), n8(8), sameAsTx(15) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the type of traffic management which is applied to the receive direction of this connection as defined in the ATM Forum. The rxTrafficDescType determines the number and meaning of the parameters in the rxTrafficDescParm attribute When sameAsTx is selected, the rxTrafficDescType as well as the rxTrafficDescParm are taken from the transmit values." DEFVAL { sameAsTx } ::= { mscARtgPnniRfCriteriaEntry 5 } mscARtgPnniRfAtmServiceCategory OBJECT-TYPE SYNTAX INTEGER { unspecifiedBitRate(0), constantBitRate(1), rtVariableBitRate(2), nrtVariableBitRate(3), derivedFromBBC(15) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the ATM service category for both directions of the connection. If this attribute is set to derivedFromBBC, the Broadband Bearer Capability (BBC) and bestEffort attributes are used to determine the atmServiceCategory of this connection. If this attribute is set to other than derivedFromBBC, the value of this attribute is used to override the provisioned BBC IE parameters. In those cases, the BBC attributes are not used. The constantBitRate service category is intended for real time applications, that is those requiring tightly constrained delay and delay variation, as would be appropriate for voice and video applications. The consistent availability of a fixed quantity of bandwidth is considered appropriate for CBR service. Cells which are delayed beyond the value specified by CellTransfer Delay are assumed to be of significantly reduce value to the application. The rtVariableBitRate service category is intended for real time applications, that is those requiring tightly constrained delay and delay variation, as would be appropriate for voice and video applications. Sources are expected to transmit at a rate which varies with time. Equivalently, the source can be described as 'bursty'. Cells which are delayed beyond the value specified by CTD are assumed to be of significantly reduced value to the application. VBR real time service may support statistical multiplexing of real time sources. The nrtVariableBitRate service category is intended for non-real time applications which have bursty traffic characteristics and which can be characterized in terms of a PCR, SCR, and MBS. For those cells which are transferred within the traffic contract, the application expects a low cell loss ratio. For all connections, it expects a bound on the mean cell transfer delay. VBR non-real time service may support statistical multiplexing of connections. The unspecifiedBitRate service is intended for non-real time applications; that is, those not requiring tightly constrained delay and delay variation. UBR sources are expected to be bursty. UBR service supports a high degree of statistical multiplexing among sources. UBR service does not specify traffic related service guarantees. No numerical commitments are made with respect to the cell loss ratio experienced by a UBR connection, or as to the cell transfer delay experienced by cells on the connection." DEFVAL { unspecifiedBitRate } ::= { mscARtgPnniRfCriteriaEntry 6 } mscARtgPnniRfFwdQosClass OBJECT-TYPE SYNTAX INTEGER { n0(0), n1(1), n2(2), n3(3), n4(4) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the quality of service for the forward direction for this connection. Class 1 supports a QOS that will meet Service Class A performance requirements (Circuit emulation, constant bit rate video). Class 2 supports a QOS that will meet Service Class B performance requirements (Variable bit rate audio and video). Class 3 supports a QOS that will meet Service Class C performance requirements (Connection-Oriented Data Transfer). Class 4 supports a QOS that will meet Service Class D performance requirements (Connectionless Data Transfer). Class 0 is the unspecified bit rate QOS class; no objective is specified for the performance parameters." DEFVAL { n0 } ::= { mscARtgPnniRfCriteriaEntry 10 } mscARtgPnniRfBwdQosClass OBJECT-TYPE SYNTAX INTEGER { n0(0), n1(1), n2(2), n3(3), n4(4), sameAsFwd(15) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the quality of service for the backward direction for this connection. Class 1 supports a QOS that will meet Service Class A performance requirements (Circuit emulation, constant bit rate video). Class 2 supports a QOS that will meet Service Class B performance requirements (Variable bit rate audio and video). Class 3 supports a QOS that will meet Service Class C performance requirements (Connection-Oriented Data Transfer). Class 4 supports a QOS that will meet Service Class D performance requirements (Connectionless Data Transfer). Class 0 is the unspecified bit rate QOS class; no objective is specified for the performance parameters. The sameAsFwd selection sets the backward quality of service to be the same as the forward quality of service." DEFVAL { sameAsFwd } ::= { mscARtgPnniRfCriteriaEntry 11 } mscARtgPnniRfBearerClassBbc OBJECT-TYPE SYNTAX INTEGER { a(1), c(3), x(16), derivedFromServiceCategory(31) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the bearer capability. It is one of the Broadband Bearer Capability (BBC) attributes. The purpose of the BBC information element is to indicate a requested broadband connection-oriented bearer service to be provided by the network. The value derivedFromServiceCategory specifies that the actual value which is used for this connection is derived from the value of the atmServiceCategory. Either, this attribute must be set to derivedFromServiceCategory, or the atmServiceCategory attribute must be set to derivedFromBBC, but not both. Class a service is a connection-oriented, constant bit rate ATM transport service. Class a service has end to end timing requirements and may require stringent cell loss, cell delay and cell delay variation performance.When a is set, the user is requesting more than an ATM only service. The network may look at the AAL to provide interworking based upon its contents. Class c service is a connection-oriented, variable bit rate ATM transport service. Class c service has no end-to-end timing requirements. When c is set, the user is requesting more than an ATM only service. The network interworking function may look at the AAL and provide service based on it. Class x service is a connection-oriented ATM transport service where the AAL, trafficType (vbr or cbr) and timing requirements are user defined (that is, transparent to the network).When x is set the user is requesting an ATM only service from the network. In this case, the network shall not process any higher layer protocol." DEFVAL { derivedFromServiceCategory } ::= { mscARtgPnniRfCriteriaEntry 12 } mscARtgPnniRfTransferCapabilityBbc OBJECT-TYPE SYNTAX INTEGER { n0(0), n1(1), n2(2), n5(5), n8(8), n9(9), n10(10), notApplicable(30), derivedFromServiceCategory(31) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the transfer capability for this connection. Uni 3.0/3.1 traffic type and end-to-end timing parameters are mapped into this parameter as follows: 0 : NoIndication, NoIndication 1 : NoIndication, yes 2 : NoIndication, no 5 : CBR, yes 8 : VBR, NoIndication 9 : VBR, yes 10: VBR, no NotApplicable specifies that the user does not want to specify the transfer capability. The CBR traffic type refers to traffic offered on services such as a constant bit rate video service or a circuit emulation. The VBR traffic type refers to traffic offered on services such as packetized audio and video, or data. The value NoIndication for traffic type is used if the user has not set the traffic type; this is also the case for end-to-end timing. The value yes for end-to-end timing indicates that end-to-end timing is required. The value no for end-to-end timing indicates that end-to-end timing is not required. The value derivedFromServiceCategory specifies that the actual value which is used for this connection is derived from the value of the atmServiceCategory. Either, this attribute must be set to derivedFromServiceCategory, or the atmServiceCategory attribute must be set to derivedFromBBC, but not both." DEFVAL { derivedFromServiceCategory } ::= { mscARtgPnniRfCriteriaEntry 13 } mscARtgPnniRfClippingBbc OBJECT-TYPE SYNTAX INTEGER { no(0), yes(1) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the value for the clipping susceptibility parameter in the BBC IE. This attribute is only used for SPVC connections. It is one of the Broadband Bearer Capability attributes. Clipping is an impairment in which the first fraction of a second of information to be transferred is lost. It occurs after a call is answered and before an associated connection is switched through." DEFVAL { no } ::= { mscARtgPnniRfCriteriaEntry 14 } mscARtgPnniRfBestEffort OBJECT-TYPE SYNTAX INTEGER { indicated(0), notIndicated(1), derivedFromServiceCategory(15) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the value of the best effort parameter in the ATM Traffic Descriptor IE. It is one of the Broadband Bearer Capability attributes. The value indicated implies that the quality of service for this connection is not guaranteed. The value notIndicated implies that the quality of service for this connection is guaranteed. The value derivedFromServiceCategory specifies that the actual value which is used for this connection is derived from the value of the atmServiceCategory. Either, this attribute must be set to derivedFromServiceCategory, or the atmServiceCategory attribute must be set to derivedFromBBC, but not both. DESCRIPTION" DEFVAL { derivedFromServiceCategory } ::= { mscARtgPnniRfCriteriaEntry 15 } mscARtgPnniRfOptimizationMetric OBJECT-TYPE SYNTAX INTEGER { cdv(0), maxCtd(1), aw(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the optimization metric to be used in the route computation; one of cell delay variation (cdv), maximum cell transfer delay (maxCtd), or administrative weight (aw)." DEFVAL { aw } ::= { mscARtgPnniRfCriteriaEntry 16 } mscARtgPnniRfRxTdpTable OBJECT-TYPE SYNTAX SEQUENCE OF MscARtgPnniRfRxTdpEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This attribute is a vector of four traffic parameters whose meanings are defined by the rxTrafficDescType attribute. The values of peak cell rate (PCR) and sustained cell rate (SCR) are expressed in cell/s. Maximum burst size (MBS) is expressed in cells. The value of CDVT is expressed in microseconds. The values of PCR, SCR, MBS and CDVT are used for usage parameter control (UPC). When rxTrafficDescType is 1 or 2, all of the parameters must be set to zero (unused). When rxTrafficDescType is 3, parameter 1 represents the PCR for CLP equal to 0 and 1 traffic. Parameter 1 must be non-zero. Parameters 2 and 3 must be set to zero (unused). When rxTrafficDescType is 4, parameter 1 represents the PCR for CLP equal to 0 and 1 traffic; parameter 2 represents the PCR for CLP equal to 0 traffic with cell discard. Parameters 1 and 2 must be non-zero. Parameter 3 must be set to zero (unused). Parameter 1 must be greater than or equal to parameter 2. When rxTrafficDescType is 5, parameter 1 represents the PCR for CLP equal to 0 and 1 traffic; parameter 2 represents the PCR for CLP equal to 0 traffic with cell tagging. Parameters 1 and 2 must be non-zero. Parameter 3 must be set to zero (unused). Parameter 1 must be greater than or equal to parameter 2. When rxTrafficDescType is a 6, parameter 1 represents the PCR for CLP equal to 0 and 1 traffic; parameter 2 represents the SCR for CLP equal to 0 and 1 traffic; parameter 3 represents the MBS for CLP equal to 0 and 1 traffic. Parameters 1, 2 and 3 must be non- zero. Parameter 1 must be greater than or equal to Parameter 2. When rxTrafficDescType is 7, parameter 1 represents the PCR for CLP equal to 0 and 1 traffic; parameter 2 represents the SCR for CLP equal to 0 traffic with cell discard; parameter 3 represents the MBS for CLP equal to 0 traffic. Parameters 1, 2 and 3 must be non- zero. Parameter 1 must be greater than or equal to parameter 2. When rxTrafficDescType is 8, parameter 1 represents the PCR for CLP equal to 0 and 1 traffic; parameter 2 represents the SCR for CLP equal to 0 traffic with cell tagging; parameter 3 represents the MBS for CLP equal to 0 traffic. Parameter 1, 2 and 3 must be non- zero. Parameter 1 must be greater than or equal to parameter 2. When rxTrafficDescType is any value from 3 through 8, parameter 4 represents the CDVT. If this value is zero, the CDVT is taken from the ConnectionAdministrator defaults for the particular atmServiceCategory of this connection. When rxTrafficDescriptorType is 3 through 8, there are certain extreme combinations of rxTrafficDescParm which are outside the capabilities of the UPC hardware. To calculate the limits, use the following formulae: I1 = 1 000 000 000 / PCR L1 = CDVT * 1000 I2 = 1 000 000 000 / SCR L2 = CDVT + (MBS - 1) * (I2 - I1) I1 and I2 must be less than or equal to 335 523 840. I1 + L1 must be less than or equal to 1 342 156 800. I2 + L2 must be less than or equal to 1 342 156 800. Note that I2 and L2 only apply when the rxTrafficDescriptorType is 6 through 8. If the values of I1, L1, I2 or L2 are closer to the limits described above, a further restriction applies. Specifically, if either: I1 > 41 940 480 or I2 > 41 940 480 or I1 + L1 > 167 769 600 or I2 + L2 > 167 769 600 then both I1 and I2 must be greater than 20 480. Parameter 5 of the rxTrafficDescParm is always unused. If the rxTrafficDescType is sameAsTx, the values in this attribute will be taken from the txTrafficDescParm." ::= { mscARtgPnniRf 388 } mscARtgPnniRfRxTdpEntry OBJECT-TYPE SYNTAX MscARtgPnniRfRxTdpEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscARtgPnniRfRxTdpTable." INDEX { mscARtgIndex, mscARtgPnniIndex, mscARtgPnniRfIndex, mscARtgPnniRfRxTdpIndex } ::= { mscARtgPnniRfRxTdpTable 1 } MscARtgPnniRfRxTdpEntry ::= SEQUENCE { mscARtgPnniRfRxTdpIndex Integer32, mscARtgPnniRfRxTdpValue Unsigned32 } mscARtgPnniRfRxTdpIndex OBJECT-TYPE SYNTAX Integer32 (1..5) ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable represents the mscARtgPnniRfRxTdpTable specific index for the mscARtgPnniRfRxTdpTable." ::= { mscARtgPnniRfRxTdpEntry 1 } mscARtgPnniRfRxTdpValue OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "This variable represents an individual value for the mscARtgPnniRfRxTdpTable." ::= { mscARtgPnniRfRxTdpEntry 2 } mscARtgPnniRfTxTdpTable OBJECT-TYPE SYNTAX SEQUENCE OF MscARtgPnniRfTxTdpEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This attribute is a vector of five traffic parameters whose meanings are defined by the txTrafficDescType attribute. The values of peak cell rate (PCR), sustained cell rate (SCR) and requested shaping rate are expressed in cell/s. Maximum burst size (MBS) is expressed in cells. CDVT is expressed in microseconds. The values of PCR, SCR, MBS and CDVT are used for connection admission control (CAC). The value of CDVT is only used for connections where the atmServiceCategory is constantBitRate. For all other values of atmServiceCategory, CDVT is ignored. The values of PCR, SCR and requested shaping rate are used to determine the actual shaping rate where traffic shaping is enabled. When txTrafficDescType is 1 or 2, all of the parameters must be set to zero. When txTrafficDescType is 3, parameter 1 represents the PCR for CLP equal to 0 and 1 traffic; parameter 4 represents the CDVT; and parameter 5 represents the requested shaping rate. A non-zero value in parameter 5 overrides any value in parameter 1. This result is used as the PCR. Parameter 1 must be non-zero. Parameters 2 and 3 must be zero. When txTrafficDescType is 4, parameter 1 represents the PCR for CLP equal to 0 and 1 traffic with cell discard; parameter 2 represents the PCR for CLP equal to 0 traffic; parameter 4 represents the CDVT; and parameter 5 represents the requested shaping rate. A non-zero value in parameter 5 overrides any value in parameter 1. This result is used as the PCR. Parameter 1 must be greater than or equal to parameter 2. Parameters 1 and 2 must be non-zero. Parameter 3 must be zero. When txTrafficDescType is 5, parameter 1 represents the PCR for CLP equal to 0 and 1 traffic with cell tagging; parameter 2 represents the PCR for CLP equal to 0 traffic; parameter 4 represents the CDVT; and parameter 5 represents the requested shaping rate. A non-zero value in parameter 5 overrides any value in parameter 1. This result is used as the PCR. Parameter 1 must be greater than or equal to parameter 2. Parameters 1 and 2 must be non-zero. Parameter 3 must be zero. When txTrafficDescType is 6, parameter 1 represents the PCR for CLP equal to 0 and 1 traffic; parameter 2 represents the SCR for CLP equal to 0 and 1 traffic; parameter 3 represents the MBS for CLP equal to 0 and 1 traffic; parameter 4 represents the CDVT; and parameter 5 represents the requested shaping rate. A non-zero value in parameter 5 overrides any value in parameter 1. This result is used as the PCR. Parameters 1, 2 and 3 must be non-zero. Parameter 1 must be greater than or equal to parameter 2. Parameter 5, must either be zero (unused) or greater than or equal to parameter 2. When txTrafficDescType is 7, parameter 1 represents the PCR for CLP equal to 0 and 1 traffic; parameter 2 represents the SCR for CLP equal to 0 with cell discard; parameter 3 represents the MBS for CLP equal to 0 traffic; parameter 4 represents the CDVT; and parameter 5 represents the requested shaping rate. A non-zero value in parameter 5 overrides any value in parameter 1. This result is used as the PCR. Parameters 1, 2 and 3 must be non-zero. Parameter 1 must be greater than or equal to parameter 2. Parameter 5, must either be zero (unused) or greater than or equal to parameter 2. When txTrafficDescType is 8, parameter 1 represents the PCR for CLP equal to 0 and 1 traffic; parameter 2 represents the SCR for CLP equal to 0 traffic with cell tagging; parameter 3 represents the MBS for CLP equal to 0 traffic; parameter 4 represents the CDVT; and parameter 5 represents the requested shaping rate. A non-zero value in parameter 5 overrides any value in parameter 1. This result is used as the PCR. Parameters 1, 2 and 3 must be non-zero. Parameter 1 must be greater than or equal to parameter 2. Parameter 5, must either be zero (unused) or greater than or equal to parameter 2. Whenever it is valid for PCR to be specified, parameter 5 may also be used to specify a requested shaping rate. A non-zero value in parameter 5 overrides the value in parameter 1 and is used as the peak cell rate in calculations of CAC and shaping rate. For txTrafficDescType 3, 4 and 5, the transmit traffic will be shaped at the next rate less than the PCR. For txTrafficDescType 6, 7 and 8, the transmit traffic will be shaped at the highest available rate which is between PCR and SCR. However, if there is no available shaping rate between PCR and SCR, traffic will be shaped at the next rate above the PCR." ::= { mscARtgPnniRf 389 } mscARtgPnniRfTxTdpEntry OBJECT-TYPE SYNTAX MscARtgPnniRfTxTdpEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscARtgPnniRfTxTdpTable." INDEX { mscARtgIndex, mscARtgPnniIndex, mscARtgPnniRfIndex, mscARtgPnniRfTxTdpIndex } ::= { mscARtgPnniRfTxTdpTable 1 } MscARtgPnniRfTxTdpEntry ::= SEQUENCE { mscARtgPnniRfTxTdpIndex Integer32, mscARtgPnniRfTxTdpValue Unsigned32 } mscARtgPnniRfTxTdpIndex OBJECT-TYPE SYNTAX Integer32 (1..5) ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable represents the mscARtgPnniRfTxTdpTable specific index for the mscARtgPnniRfTxTdpTable." ::= { mscARtgPnniRfTxTdpEntry 1 } mscARtgPnniRfTxTdpValue OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "This variable represents an individual value for the mscARtgPnniRfTxTdpTable." ::= { mscARtgPnniRfTxTdpEntry 2 } mscARtgPnniRfFqpTable OBJECT-TYPE SYNTAX SEQUENCE OF MscARtgPnniRfFqpEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This attribute is a vector of three elements that specify the quality of service parameters for the forward direction for this connection. This attribute is used for SPVC connections. The cdv element specifies the acceptable peak-to-peak Cell Delay Variation (CDV) of real-time connections (CBR, and rt-VBR). It is signalled through the extended QoS information element. The ctd specifies the acceptable maximum Cell Transfer Delay (maxCtd) of real-time connections (CBR, and rt-VBR). It is signalled through the end to end transit delay information element. The clr specifies the acceptable Cell Loss Ratio (CLR) of CBR, rt- VBR, and nrt-VBR connections. It is signalled through the extended QoS information element." ::= { mscARtgPnniRf 390 } mscARtgPnniRfFqpEntry OBJECT-TYPE SYNTAX MscARtgPnniRfFqpEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscARtgPnniRfFqpTable." INDEX { mscARtgIndex, mscARtgPnniIndex, mscARtgPnniRfIndex, mscARtgPnniRfFqpIndex } ::= { mscARtgPnniRfFqpTable 1 } MscARtgPnniRfFqpEntry ::= SEQUENCE { mscARtgPnniRfFqpIndex INTEGER, mscARtgPnniRfFqpValue Unsigned32 } mscARtgPnniRfFqpIndex OBJECT-TYPE SYNTAX INTEGER { cdv(0), ctd(1), clr(2) } ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable represents the mscARtgPnniRfFqpTable specific index for the mscARtgPnniRfFqpTable." ::= { mscARtgPnniRfFqpEntry 1 } mscARtgPnniRfFqpValue OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "This variable represents an individual value for the mscARtgPnniRfFqpTable." ::= { mscARtgPnniRfFqpEntry 2 } mscARtgPnniRfBqpTable OBJECT-TYPE SYNTAX SEQUENCE OF MscARtgPnniRfBqpEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This attribute is a vector of three elements that specify the quality of service parameters for the backward direction for this connection. This attribute is used for SPVC connections. The cdv element specifies the acceptable peak-to-peak Cell Delay Variation (CDV) of real-time connections (CBR, and rt-VBR). It is signalled through the extended QoS information element. The ctd specifies the acceptable maximum Cell Transfer Delay (maxCtd) of real-time connections (CBR, and rt-VBR). It is signalled through the end to end transit delay information element. The clr specifies the acceptable Cell Loss Ratio (CLR) of CBR, rt- VBR, and nrt-VBR connections. It is signalled through the extended QoS information element." ::= { mscARtgPnniRf 393 } mscARtgPnniRfBqpEntry OBJECT-TYPE SYNTAX MscARtgPnniRfBqpEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscARtgPnniRfBqpTable." INDEX { mscARtgIndex, mscARtgPnniIndex, mscARtgPnniRfIndex, mscARtgPnniRfBqpIndex } ::= { mscARtgPnniRfBqpTable 1 } MscARtgPnniRfBqpEntry ::= SEQUENCE { mscARtgPnniRfBqpIndex INTEGER, mscARtgPnniRfBqpValue Unsigned32 } mscARtgPnniRfBqpIndex OBJECT-TYPE SYNTAX INTEGER { cdv(0), ctd(1), clr(2) } ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable represents the mscARtgPnniRfBqpTable specific index for the mscARtgPnniRfBqpTable." ::= { mscARtgPnniRfBqpEntry 1 } mscARtgPnniRfBqpValue OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "This variable represents an individual value for the mscARtgPnniRfBqpTable." ::= { mscARtgPnniRfBqpEntry 2 } -- ARtg Pnni ConfiguredNode/ -- This component represents the participation of this node at one level -- in the PNNI hierarchy. mscARtgPnniCfgNode OBJECT IDENTIFIER ::= { mscARtgPnni 3 } mscARtgPnniCfgNodeRowStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF MscARtgPnniCfgNodeRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This entry controls the addition and deletion of mscARtgPnniCfgNode components." ::= { mscARtgPnniCfgNode 1 } mscARtgPnniCfgNodeRowStatusEntry OBJECT-TYPE SYNTAX MscARtgPnniCfgNodeRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A single entry in the table represents a single mscARtgPnniCfgNode component." INDEX { mscARtgIndex, mscARtgPnniIndex, mscARtgPnniCfgNodeIndex } ::= { mscARtgPnniCfgNodeRowStatusTable 1 } MscARtgPnniCfgNodeRowStatusEntry ::= SEQUENCE { mscARtgPnniCfgNodeRowStatus RowStatus, mscARtgPnniCfgNodeComponentName DisplayString, mscARtgPnniCfgNodeStorageType StorageType, mscARtgPnniCfgNodeIndex Integer32 } mscARtgPnniCfgNodeRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-write STATUS mandatory DESCRIPTION "This variable is used as the basis for SNMP naming of mscARtgPnniCfgNode components. These components can be added and deleted." ::= { mscARtgPnniCfgNodeRowStatusEntry 1 } mscARtgPnniCfgNodeComponentName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This variable provides the component's string name for use with the ASCII Console Interface" ::= { mscARtgPnniCfgNodeRowStatusEntry 2 } mscARtgPnniCfgNodeStorageType OBJECT-TYPE SYNTAX StorageType ACCESS read-only STATUS mandatory DESCRIPTION "This variable represents the storage type value for the mscARtgPnniCfgNode tables." ::= { mscARtgPnniCfgNodeRowStatusEntry 4 } mscARtgPnniCfgNodeIndex OBJECT-TYPE SYNTAX Integer32 (0..104) ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable represents the index for the mscARtgPnniCfgNode tables." ::= { mscARtgPnniCfgNodeRowStatusEntry 10 } mscARtgPnniCfgNodeProvTable OBJECT-TYPE SYNTAX SEQUENCE OF MscARtgPnniCfgNodeProvEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This group contains the provisionable attributes of a ConfiguredNode component." ::= { mscARtgPnniCfgNode 10 } mscARtgPnniCfgNodeProvEntry OBJECT-TYPE SYNTAX MscARtgPnniCfgNodeProvEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscARtgPnniCfgNodeProvTable." INDEX { mscARtgIndex, mscARtgPnniIndex, mscARtgPnniCfgNodeIndex } ::= { mscARtgPnniCfgNodeProvTable 1 } MscARtgPnniCfgNodeProvEntry ::= SEQUENCE { mscARtgPnniCfgNodeNodeId HexString, mscARtgPnniCfgNodePeerGroupId HexString } mscARtgPnniCfgNodeNodeId OBJECT-TYPE SYNTAX HexString (SIZE (0..22)) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the node id of the configured node. If this attribute is set to null, then the node id is computed as follows: If this is the lowest configured node, then the node id is computed as the level (one octet), followed by the integer value 160 (one octet), followed by the node address (20 octets). If this is not the lowest configured node, then the node id is computed as the level (one octet), followed by the 14 octet peer group id of the child peer group which the LGN represents, followed by the ESI specified in the node address (6 octets), followed by the integer value 0 (one octet)." ::= { mscARtgPnniCfgNodeProvEntry 2 } mscARtgPnniCfgNodePeerGroupId OBJECT-TYPE SYNTAX HexString (SIZE (0..14)) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute allows the peer group id of the Logical Group Node (LGN) to be set. The peer group id is specified by 28 hex digits where the first octet represents the level of the node and the remaining 13 octets form the End System Address. If this attribute is set to the null string then the peer group id is computed as follows: The peer group id for a lowest level node is computed to be the node's level (one octet), followed by the first bits of the node's address, followed by zero or more padding 0 bits. The peer group id for an LGN is computed to be the LGN's level (one octet), followed by the first bits of the id of the peer group which this LGN represents." ::= { mscARtgPnniCfgNodeProvEntry 3 } mscARtgPnniCfgNodeOperTable OBJECT-TYPE SYNTAX SEQUENCE OF MscARtgPnniCfgNodeOperEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This group contains the generic operational attributes of a ConfiguredNode component." ::= { mscARtgPnniCfgNode 11 } mscARtgPnniCfgNodeOperEntry OBJECT-TYPE SYNTAX MscARtgPnniCfgNodeOperEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscARtgPnniCfgNodeOperTable." INDEX { mscARtgIndex, mscARtgPnniIndex, mscARtgPnniCfgNodeIndex } ::= { mscARtgPnniCfgNodeOperTable 1 } MscARtgPnniCfgNodeOperEntry ::= SEQUENCE { mscARtgPnniCfgNodeNodeAddress HexString, mscARtgPnniCfgNodeOpNodeId HexString, mscARtgPnniCfgNodeOpPeerGroupId HexString, mscARtgPnniCfgNodeNumNeighbors Unsigned32, mscARtgPnniCfgNodeNumRccs Unsigned32, mscARtgPnniCfgNodeCurrentLeadershipPriority Unsigned32, mscARtgPnniCfgNodePglElectionState INTEGER } mscARtgPnniCfgNodeNodeAddress OBJECT-TYPE SYNTAX HexString (SIZE (20)) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the address of the node at this level. At the lowest level, the nodeAddress is determined by the value of the nodeAddressPrefix attribute for the ARtg Pnni component followed by the level of this CfgNode. For LGNs, the nodeAddress is the same as the nodeAddress of the node at the lowest level, with the selector field set to the level of the peer group containing the LGN." ::= { mscARtgPnniCfgNodeOperEntry 1 } mscARtgPnniCfgNodeOpNodeId OBJECT-TYPE SYNTAX HexString (SIZE (22)) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the node id of the node at this level. The default node id is computed as follows: If this is the lowest level node, then the default node id is computed as the level (one octet), followed by the integer value 160 (one octet), followed by the node address (20 octets). If this is not the lowest level node, then the default node id is computed as the level (one octet), followed by the 14 octet peer group id of the child peer group which the LGN represents, followed by the ESI specified in the node address (6 octets), followed by the integer value 0 (one octet)." ::= { mscARtgPnniCfgNodeOperEntry 2 } mscARtgPnniCfgNodeOpPeerGroupId OBJECT-TYPE SYNTAX HexString (SIZE (14)) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the peer group id of the node at this level. The value is determined by the provisioned peerGroupId attribute." ::= { mscARtgPnniCfgNodeOperEntry 3 } mscARtgPnniCfgNodeNumNeighbors OBJECT-TYPE SYNTAX Unsigned32 (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the number of PNNI nodes which are neighbors of this node at this level." ::= { mscARtgPnniCfgNodeOperEntry 4 } mscARtgPnniCfgNodeNumRccs OBJECT-TYPE SYNTAX Unsigned32 (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the number of Routing Control Channels to this node's neighbors at this level." ::= { mscARtgPnniCfgNodeOperEntry 5 } mscARtgPnniCfgNodeCurrentLeadershipPriority OBJECT-TYPE SYNTAX Unsigned32 (0..205) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the leadership priority of the node that this node believes should be the peer group leader at this point in time." ::= { mscARtgPnniCfgNodeOperEntry 6 } mscARtgPnniCfgNodePglElectionState OBJECT-TYPE SYNTAX INTEGER { starting(0), awaiting(1), awaitingFull(2), initialDelay(3), calculating(4), operNotPgl(5), operPgl(6), awaitUnanimity(7), hungElection(8), awaitReElection(9) } ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the current state of the peer group leader election process. The following are the possible values for this attribute: starting: the initial state of the state machine. awaiting: the node has started the Hello Finite State Machine on at least one link, and no peer has been found yet. awaitingFull: no database synchronization process has been completed yet but at least one neighboring peer has been found. initialDelay: Database synchronization has been completed with at least one neighboring peer. The node must wait pglInitTime second before it can select and advertise its preferred Peer Group Leader (PGL). calculating: the node is in the process of calculating what its new choice for preferred PGL will be. operNotPgl: a non PGL node is in the process of determining which node has the highest priority to be PGL by examining PTSEs sent by other nodes. operPgl: a PGL node is in the process of determining if another node has a higher priority than itself by examining PTSEs sent by other nodes. awaitUnanimity: the node has chosen itself as PGL. If the node has been elected unanimously, it generates a Unanimity event. It waits for unanimity or expiration of the overrideDelay timer before declaring itself peer group leader. hungElection: the node has chosen itself as PGL with less than 2/3 of the other nodes advertising it as their preferred PGL. In this case either this node should change its choice of preferred PGL, or the other nodes are going to accept it as PGL. awaitReElection: the node has lost connectivity to the current PGL. The connectivity must be reestablished before the reElectionInterval timer fires, otherwise the election is redone." ::= { mscARtgPnniCfgNodeOperEntry 7 } -- ARtg Pnni CfgNode/ SummaryAddress/
, -- , -- A summary address is an abbreviation of a set of addresses, -- represented by an address prefix that all of the summarized -- addresses have in common. -- A suppressed summary address is used to suppress the -- advertisement of addresses which match this prefix, regardless of -- scope. -- -- The prefixLength specifies the number of prefix bits of the address -- and reachability specifies whether the address is to summarize -- internal or exterior addresses. -- -- An internal address is an address of a destination that is directly -- attached to the logical node. An exterior address is an address of a -- destination that is located outside of the PNNI routing domain but -- can be reached through a port attached to the logical node. mscARtgPnniCfgNodeSAddr OBJECT IDENTIFIER ::= { mscARtgPnniCfgNode 2 } mscARtgPnniCfgNodeSAddrRowStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF MscARtgPnniCfgNodeSAddrRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This entry controls the addition and deletion of mscARtgPnniCfgNodeSAddr components." ::= { mscARtgPnniCfgNodeSAddr 1 } mscARtgPnniCfgNodeSAddrRowStatusEntry OBJECT-TYPE SYNTAX MscARtgPnniCfgNodeSAddrRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A single entry in the table represents a single mscARtgPnniCfgNodeSAddr component." INDEX { mscARtgIndex, mscARtgPnniIndex, mscARtgPnniCfgNodeIndex, mscARtgPnniCfgNodeSAddrAddressIndex, mscARtgPnniCfgNodeSAddrPrefixLengthIndex, mscARtgPnniCfgNodeSAddrReachabilityIndex } ::= { mscARtgPnniCfgNodeSAddrRowStatusTable 1 } MscARtgPnniCfgNodeSAddrRowStatusEntry ::= SEQUENCE { mscARtgPnniCfgNodeSAddrRowStatus RowStatus, mscARtgPnniCfgNodeSAddrComponentName DisplayString, mscARtgPnniCfgNodeSAddrStorageType StorageType, mscARtgPnniCfgNodeSAddrAddressIndex HexString, mscARtgPnniCfgNodeSAddrPrefixLengthIndex Integer32, mscARtgPnniCfgNodeSAddrReachabilityIndex INTEGER } mscARtgPnniCfgNodeSAddrRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-write STATUS mandatory DESCRIPTION "This variable is used as the basis for SNMP naming of mscARtgPnniCfgNodeSAddr components. These components can be added and deleted." ::= { mscARtgPnniCfgNodeSAddrRowStatusEntry 1 } mscARtgPnniCfgNodeSAddrComponentName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This variable provides the component's string name for use with the ASCII Console Interface" ::= { mscARtgPnniCfgNodeSAddrRowStatusEntry 2 } mscARtgPnniCfgNodeSAddrStorageType OBJECT-TYPE SYNTAX StorageType ACCESS read-only STATUS mandatory DESCRIPTION "This variable represents the storage type value for the mscARtgPnniCfgNodeSAddr tables." ::= { mscARtgPnniCfgNodeSAddrRowStatusEntry 4 } mscARtgPnniCfgNodeSAddrAddressIndex OBJECT-TYPE SYNTAX HexString (SIZE (19)) ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable represents an index for the mscARtgPnniCfgNodeSAddr tables." ::= { mscARtgPnniCfgNodeSAddrRowStatusEntry 10 } mscARtgPnniCfgNodeSAddrPrefixLengthIndex OBJECT-TYPE SYNTAX Integer32 (1..152) ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable represents an index for the mscARtgPnniCfgNodeSAddr tables." ::= { mscARtgPnniCfgNodeSAddrRowStatusEntry 11 } mscARtgPnniCfgNodeSAddrReachabilityIndex OBJECT-TYPE SYNTAX INTEGER { internal(0), exterior(1) } ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable represents an index for the mscARtgPnniCfgNodeSAddr tables." ::= { mscARtgPnniCfgNodeSAddrRowStatusEntry 12 } mscARtgPnniCfgNodeSAddrProvTable OBJECT-TYPE SYNTAX SEQUENCE OF MscARtgPnniCfgNodeSAddrProvEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This group contains the provisionable attributes of a SummaryAddress component. A summary address is an abbreviation of a set of addresses, represented by an address prefix that all of the summarized addresses have in common. A suppressed summary address is used to suppress the advertisement of addresses which match this prefix, regardless of scope." ::= { mscARtgPnniCfgNodeSAddr 10 } mscARtgPnniCfgNodeSAddrProvEntry OBJECT-TYPE SYNTAX MscARtgPnniCfgNodeSAddrProvEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscARtgPnniCfgNodeSAddrProvTable." INDEX { mscARtgIndex, mscARtgPnniIndex, mscARtgPnniCfgNodeIndex, mscARtgPnniCfgNodeSAddrAddressIndex, mscARtgPnniCfgNodeSAddrPrefixLengthIndex, mscARtgPnniCfgNodeSAddrReachabilityIndex } ::= { mscARtgPnniCfgNodeSAddrProvTable 1 } MscARtgPnniCfgNodeSAddrProvEntry ::= SEQUENCE { mscARtgPnniCfgNodeSAddrSuppress INTEGER } mscARtgPnniCfgNodeSAddrSuppress OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies whether or not the address should be suppressed. If this attribute is set to true, then all addresses matching that prefix will not be advertised above this level." DEFVAL { false } ::= { mscARtgPnniCfgNodeSAddrProvEntry 2 } mscARtgPnniCfgNodeSAddrOperTable OBJECT-TYPE SYNTAX SEQUENCE OF MscARtgPnniCfgNodeSAddrOperEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This group contains the operational attributes of a SummaryAddress component." ::= { mscARtgPnniCfgNodeSAddr 11 } mscARtgPnniCfgNodeSAddrOperEntry OBJECT-TYPE SYNTAX MscARtgPnniCfgNodeSAddrOperEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscARtgPnniCfgNodeSAddrOperTable." INDEX { mscARtgIndex, mscARtgPnniIndex, mscARtgPnniCfgNodeIndex, mscARtgPnniCfgNodeSAddrAddressIndex, mscARtgPnniCfgNodeSAddrPrefixLengthIndex, mscARtgPnniCfgNodeSAddrReachabilityIndex } ::= { mscARtgPnniCfgNodeSAddrOperTable 1 } MscARtgPnniCfgNodeSAddrOperEntry ::= SEQUENCE { mscARtgPnniCfgNodeSAddrState INTEGER, mscARtgPnniCfgNodeSAddrScope INTEGER } mscARtgPnniCfgNodeSAddrState OBJECT-TYPE SYNTAX INTEGER { advertising(0), suppressing(1), inactive(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the state of the address: one of advertising, suppressing or inactive. inactive: the summary address has been configured but is not suppressing or summarizing any ATM addresses. suppressing: the summary address has suppressed at least one ATM address on the node. advertising: the summary address is summarizing at least one ATM address on the node." ::= { mscARtgPnniCfgNodeSAddrOperEntry 1 } mscARtgPnniCfgNodeSAddrScope OBJECT-TYPE SYNTAX INTEGER (-1..104) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the scope of the summary address. The scope corresponds to the scope of the underlying summarized address with the highest advertised scope. A value of -1 means the scope is unknown." ::= { mscARtgPnniCfgNodeSAddrOperEntry 2 } -- -- *** THIS SUBTREE CURRENTLY NOT IMPLEMENTED *** -- -- ARtg Pnni CfgNode/n Neighbor/ -- This component represents the operational attributes for a neighbor -- node at this level. mscARtgPnniCfgNodeNbr OBJECT IDENTIFIER ::= { mscARtgPnniCfgNode 3 } mscARtgPnniCfgNodeNbrRowStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF MscARtgPnniCfgNodeNbrRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "*** THIS TABLE CURRENTLY NOT IMPLEMENTED *** This entry controls the addition and deletion of mscARtgPnniCfgNodeNbr components." ::= { mscARtgPnniCfgNodeNbr 1 } mscARtgPnniCfgNodeNbrRowStatusEntry OBJECT-TYPE SYNTAX MscARtgPnniCfgNodeNbrRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A single entry in the table represents a single mscARtgPnniCfgNodeNbr component." INDEX { mscARtgIndex, mscARtgPnniIndex, mscARtgPnniCfgNodeIndex, mscARtgPnniCfgNodeNbrIndex } ::= { mscARtgPnniCfgNodeNbrRowStatusTable 1 } MscARtgPnniCfgNodeNbrRowStatusEntry ::= SEQUENCE { mscARtgPnniCfgNodeNbrRowStatus RowStatus, mscARtgPnniCfgNodeNbrComponentName DisplayString, mscARtgPnniCfgNodeNbrStorageType StorageType, mscARtgPnniCfgNodeNbrIndex HexString } mscARtgPnniCfgNodeNbrRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-only STATUS mandatory DESCRIPTION "This variable is used as the basis for SNMP naming of mscARtgPnniCfgNodeNbr components. These components cannot be added nor deleted." ::= { mscARtgPnniCfgNodeNbrRowStatusEntry 1 } mscARtgPnniCfgNodeNbrComponentName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This variable provides the component's string name for use with the ASCII Console Interface" ::= { mscARtgPnniCfgNodeNbrRowStatusEntry 2 } mscARtgPnniCfgNodeNbrStorageType OBJECT-TYPE SYNTAX StorageType ACCESS read-only STATUS mandatory DESCRIPTION "This variable represents the storage type value for the mscARtgPnniCfgNodeNbr tables." ::= { mscARtgPnniCfgNodeNbrRowStatusEntry 4 } mscARtgPnniCfgNodeNbrIndex OBJECT-TYPE SYNTAX HexString (SIZE (22)) ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable represents the index for the mscARtgPnniCfgNodeNbr tables." ::= { mscARtgPnniCfgNodeNbrRowStatusEntry 10 } mscARtgPnniCfgNodeNbrOperTable OBJECT-TYPE SYNTAX SEQUENCE OF MscARtgPnniCfgNodeNbrOperEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "*** THIS TABLE CURRENTLY NOT IMPLEMENTED *** This group contains the operational attributes of a Neighbor component." ::= { mscARtgPnniCfgNodeNbr 10 } mscARtgPnniCfgNodeNbrOperEntry OBJECT-TYPE SYNTAX MscARtgPnniCfgNodeNbrOperEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscARtgPnniCfgNodeNbrOperTable." INDEX { mscARtgIndex, mscARtgPnniIndex, mscARtgPnniCfgNodeIndex, mscARtgPnniCfgNodeNbrIndex } ::= { mscARtgPnniCfgNodeNbrOperTable 1 } MscARtgPnniCfgNodeNbrOperEntry ::= SEQUENCE { mscARtgPnniCfgNodeNbrPeerState INTEGER } mscARtgPnniCfgNodeNbrPeerState OBJECT-TYPE SYNTAX INTEGER { npDown(0), negotiating(1), exchanging(2), loading(3), full(4) } ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the state of the routing database exchange with the peer node. npDown: there are no active links (i.e. in the twoWayInside Hello state) to the neighboring peer. negotiating: the first step in creating an adjacency between the two neighboring peers; this step determines which node is the master, and what the initial DS sequence number will be. exchanging: the node describes its topology database by sending Database Summary packets to the neighboring peer. loading: a full sequence of Database Summary packets has been exchanged with the neighboring peer, and the required PTSEs are requested and at least one has not yet been received. full: All PTSEs known to be available have been received from the neighboring peer. At this point the all ports leading to the neighbor node will be flooded in PTSEs within the peer group." ::= { mscARtgPnniCfgNodeNbrOperEntry 2 } mscARtgPnniCfgNodeNbrStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF MscARtgPnniCfgNodeNbrStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "*** THIS TABLE CURRENTLY NOT IMPLEMENTED *** This group contains the statistical operational attributes of a Neighbor component." ::= { mscARtgPnniCfgNodeNbr 11 } mscARtgPnniCfgNodeNbrStatsEntry OBJECT-TYPE SYNTAX MscARtgPnniCfgNodeNbrStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscARtgPnniCfgNodeNbrStatsTable." INDEX { mscARtgIndex, mscARtgPnniIndex, mscARtgPnniCfgNodeIndex, mscARtgPnniCfgNodeNbrIndex } ::= { mscARtgPnniCfgNodeNbrStatsTable 1 } MscARtgPnniCfgNodeNbrStatsEntry ::= SEQUENCE { mscARtgPnniCfgNodeNbrPtspRx Counter32, mscARtgPnniCfgNodeNbrPtspTx Counter32, mscARtgPnniCfgNodeNbrPtseRx Counter32, mscARtgPnniCfgNodeNbrPtseTx Counter32, mscARtgPnniCfgNodeNbrPtseReqRx Counter32, mscARtgPnniCfgNodeNbrPtseReqTx Counter32, mscARtgPnniCfgNodeNbrPtseAcksRx Counter32, mscARtgPnniCfgNodeNbrPtseAcksTx Counter32, mscARtgPnniCfgNodeNbrDbSummariesRx Counter32, mscARtgPnniCfgNodeNbrDbSummariesTx Counter32, mscARtgPnniCfgNodeNbrBadPtspRx Counter32, mscARtgPnniCfgNodeNbrBadPtseRx Counter32, mscARtgPnniCfgNodeNbrBadPtseReqRx Counter32, mscARtgPnniCfgNodeNbrBadPtseAckRx Counter32, mscARtgPnniCfgNodeNbrBadDbSummariesRx Counter32 } mscARtgPnniCfgNodeNbrPtspRx OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS mandatory DESCRIPTION "This attribute counts the PNNI Topology State Packets received from the neighbor node. The counter wraps when it exceeds the maximum value." ::= { mscARtgPnniCfgNodeNbrStatsEntry 1 } mscARtgPnniCfgNodeNbrPtspTx OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS mandatory DESCRIPTION "This attribute counts the total number of PTSPs send to the neighbor node.The counter wraps when it exceeds the maximum value." ::= { mscARtgPnniCfgNodeNbrStatsEntry 2 } mscARtgPnniCfgNodeNbrPtseRx OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS mandatory DESCRIPTION "This attribute counts the total number of PTSEs received from the neighbor node. The counter wraps when it exceeds the maximum value." ::= { mscARtgPnniCfgNodeNbrStatsEntry 3 } mscARtgPnniCfgNodeNbrPtseTx OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS mandatory DESCRIPTION "This attribute counts the total number of PTSEs sent to the neighbor node. The counter wraps when it exceeds the maximum value." ::= { mscARtgPnniCfgNodeNbrStatsEntry 4 } mscARtgPnniCfgNodeNbrPtseReqRx OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS mandatory DESCRIPTION "This attribute counts the total number of PTSE requests received from the neighbor node. The counter wraps when it exceeds the maximum value." ::= { mscARtgPnniCfgNodeNbrStatsEntry 5 } mscARtgPnniCfgNodeNbrPtseReqTx OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS mandatory DESCRIPTION "This attribute counts the total number of PTSE requests sent to the neighbor node. The counter wraps when it exceeds the maximum value." ::= { mscARtgPnniCfgNodeNbrStatsEntry 6 } mscARtgPnniCfgNodeNbrPtseAcksRx OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS mandatory DESCRIPTION "This attribute counts the total number of PTSE acknowledgments received from the neighbor node. The counter wraps when it exceeds the maximum value." ::= { mscARtgPnniCfgNodeNbrStatsEntry 7 } mscARtgPnniCfgNodeNbrPtseAcksTx OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS mandatory DESCRIPTION "This attribute counts the total number of PTSE acknowledgments sent to the neighbor node. The counter wraps when it exceeds the maximum value." ::= { mscARtgPnniCfgNodeNbrStatsEntry 8 } mscARtgPnniCfgNodeNbrDbSummariesRx OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS mandatory DESCRIPTION "This attribute counts the number of database summary packets received from the neighbor. The counter wraps when it exceeds the maximum value." ::= { mscARtgPnniCfgNodeNbrStatsEntry 9 } mscARtgPnniCfgNodeNbrDbSummariesTx OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS mandatory DESCRIPTION "This attribute counts the number of database summary packets transmitted to the neighbor. The counter wraps when it exceeds the maximum value." ::= { mscARtgPnniCfgNodeNbrStatsEntry 10 } mscARtgPnniCfgNodeNbrBadPtspRx OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS mandatory DESCRIPTION "This attribute counts the total number of invalid PTSP packets received from the neighbor node. The counter wraps when it exceeds the maximum value." ::= { mscARtgPnniCfgNodeNbrStatsEntry 11 } mscARtgPnniCfgNodeNbrBadPtseRx OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS mandatory DESCRIPTION "This attribute counts the total number of invalid PTSE packets received to the neighbor node. The counter wraps when it exceeds the maximum value." ::= { mscARtgPnniCfgNodeNbrStatsEntry 12 } mscARtgPnniCfgNodeNbrBadPtseReqRx OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS mandatory DESCRIPTION "This attribute counts the total number of invalid PTSE requests received from the neighbor node. The counter wraps when it exceeds the maximum value." ::= { mscARtgPnniCfgNodeNbrStatsEntry 13 } mscARtgPnniCfgNodeNbrBadPtseAckRx OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS mandatory DESCRIPTION "This attribute counts the total number of invalid PTSE acknowledgments received from the neighbor node. The counter wraps when it exceeds the maximum value." ::= { mscARtgPnniCfgNodeNbrStatsEntry 14 } mscARtgPnniCfgNodeNbrBadDbSummariesRx OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS mandatory DESCRIPTION "This attribute counts the total number of invalid database summary packets received from the neighbor. The counter wraps when it exceeds the maximum value." ::= { mscARtgPnniCfgNodeNbrStatsEntry 15 } mscARtgPnniCfgNodeNbrRccListTable OBJECT-TYPE SYNTAX SEQUENCE OF MscARtgPnniCfgNodeNbrRccListEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "*** THIS TABLE CURRENTLY NOT IMPLEMENTED *** This attribute indicates the component names of all Routing Control Channels to the neighbor PNNI node." ::= { mscARtgPnniCfgNodeNbr 385 } mscARtgPnniCfgNodeNbrRccListEntry OBJECT-TYPE SYNTAX MscARtgPnniCfgNodeNbrRccListEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscARtgPnniCfgNodeNbrRccListTable." INDEX { mscARtgIndex, mscARtgPnniIndex, mscARtgPnniCfgNodeIndex, mscARtgPnniCfgNodeNbrIndex, mscARtgPnniCfgNodeNbrRccListValue } ::= { mscARtgPnniCfgNodeNbrRccListTable 1 } MscARtgPnniCfgNodeNbrRccListEntry ::= SEQUENCE { mscARtgPnniCfgNodeNbrRccListValue RowPointer } mscARtgPnniCfgNodeNbrRccListValue OBJECT-TYPE SYNTAX RowPointer ACCESS read-only STATUS mandatory DESCRIPTION "This variable represents both the value and the index for the mscARtgPnniCfgNodeNbrRccListTable." ::= { mscARtgPnniCfgNodeNbrRccListEntry 1 } -- ARtg Pnni CfgNode/ DefSAddr -- A default summary address is an internal summary address -- computed for every logical group node as follows: -- If this is not the lowest configured node, then the default summary -- address is identical to the peer group id that this logical group -- represents. -- If this is the lowest configured node but not at level 104, then the -- default summary address is the 13-octet prefix of the node's -- address. -- A node at level 104 has no default summary address. mscARtgPnniCfgNodeDefSAddr OBJECT IDENTIFIER ::= { mscARtgPnniCfgNode 4 } mscARtgPnniCfgNodeDefSAddrRowStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF MscARtgPnniCfgNodeDefSAddrRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This entry controls the addition and deletion of mscARtgPnniCfgNodeDefSAddr components." ::= { mscARtgPnniCfgNodeDefSAddr 1 } mscARtgPnniCfgNodeDefSAddrRowStatusEntry OBJECT-TYPE SYNTAX MscARtgPnniCfgNodeDefSAddrRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A single entry in the table represents a single mscARtgPnniCfgNodeDefSAddr component." INDEX { mscARtgIndex, mscARtgPnniIndex, mscARtgPnniCfgNodeIndex, mscARtgPnniCfgNodeDefSAddrIndex } ::= { mscARtgPnniCfgNodeDefSAddrRowStatusTable 1 } MscARtgPnniCfgNodeDefSAddrRowStatusEntry ::= SEQUENCE { mscARtgPnniCfgNodeDefSAddrRowStatus RowStatus, mscARtgPnniCfgNodeDefSAddrComponentName DisplayString, mscARtgPnniCfgNodeDefSAddrStorageType StorageType, mscARtgPnniCfgNodeDefSAddrIndex NonReplicated } mscARtgPnniCfgNodeDefSAddrRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-only STATUS mandatory DESCRIPTION "This variable is used as the basis for SNMP naming of mscARtgPnniCfgNodeDefSAddr components. These components cannot be added nor deleted." ::= { mscARtgPnniCfgNodeDefSAddrRowStatusEntry 1 } mscARtgPnniCfgNodeDefSAddrComponentName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This variable provides the component's string name for use with the ASCII Console Interface" ::= { mscARtgPnniCfgNodeDefSAddrRowStatusEntry 2 } mscARtgPnniCfgNodeDefSAddrStorageType OBJECT-TYPE SYNTAX StorageType ACCESS read-only STATUS mandatory DESCRIPTION "This variable represents the storage type value for the mscARtgPnniCfgNodeDefSAddr tables." ::= { mscARtgPnniCfgNodeDefSAddrRowStatusEntry 4 } mscARtgPnniCfgNodeDefSAddrIndex OBJECT-TYPE SYNTAX NonReplicated ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable represents the index for the mscARtgPnniCfgNodeDefSAddr tables." ::= { mscARtgPnniCfgNodeDefSAddrRowStatusEntry 10 } mscARtgPnniCfgNodeDefSAddrDefAddrTable OBJECT-TYPE SYNTAX SEQUENCE OF MscARtgPnniCfgNodeDefSAddrDefAddrEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This group contains the operational attributes of a DefSummaryAddress component." ::= { mscARtgPnniCfgNodeDefSAddr 10 } mscARtgPnniCfgNodeDefSAddrDefAddrEntry OBJECT-TYPE SYNTAX MscARtgPnniCfgNodeDefSAddrDefAddrEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscARtgPnniCfgNodeDefSAddrDefAddrTable." INDEX { mscARtgIndex, mscARtgPnniIndex, mscARtgPnniCfgNodeIndex, mscARtgPnniCfgNodeDefSAddrIndex } ::= { mscARtgPnniCfgNodeDefSAddrDefAddrTable 1 } MscARtgPnniCfgNodeDefSAddrDefAddrEntry ::= SEQUENCE { mscARtgPnniCfgNodeDefSAddrAddress HexString } mscARtgPnniCfgNodeDefSAddrAddress OBJECT-TYPE SYNTAX HexString (SIZE (13)) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the default summary address of the node at this level." ::= { mscARtgPnniCfgNodeDefSAddrDefAddrEntry 1 } mscARtgPnniCfgNodeDefSAddrOperTable OBJECT-TYPE SYNTAX SEQUENCE OF MscARtgPnniCfgNodeDefSAddrOperEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This group contains the operational attributes of a SummaryAddress component." ::= { mscARtgPnniCfgNodeDefSAddr 11 } mscARtgPnniCfgNodeDefSAddrOperEntry OBJECT-TYPE SYNTAX MscARtgPnniCfgNodeDefSAddrOperEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscARtgPnniCfgNodeDefSAddrOperTable." INDEX { mscARtgIndex, mscARtgPnniIndex, mscARtgPnniCfgNodeIndex, mscARtgPnniCfgNodeDefSAddrIndex } ::= { mscARtgPnniCfgNodeDefSAddrOperTable 1 } MscARtgPnniCfgNodeDefSAddrOperEntry ::= SEQUENCE { mscARtgPnniCfgNodeDefSAddrState INTEGER, mscARtgPnniCfgNodeDefSAddrScope INTEGER } mscARtgPnniCfgNodeDefSAddrState OBJECT-TYPE SYNTAX INTEGER { advertising(0), suppressing(1), inactive(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the state of the address: one of advertising, suppressing or inactive. inactive: the summary address has been configured but is not suppressing or summarizing any ATM addresses. suppressing: the summary address has suppressed at least one ATM address on the node. advertising: the summary address is summarizing at least one ATM address on the node." ::= { mscARtgPnniCfgNodeDefSAddrOperEntry 1 } mscARtgPnniCfgNodeDefSAddrScope OBJECT-TYPE SYNTAX INTEGER (-1..104) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the scope of the summary address. The scope corresponds to the scope of the underlying summarized address with the highest advertised scope. A value of -1 means the scope is unknown." ::= { mscARtgPnniCfgNodeDefSAddrOperEntry 2 } -- -- *** THIS SUBTREE CURRENTLY NOT IMPLEMENTED *** -- -- ARtg Pnni Topology/ -- -- The Topology component provides access to information in this -- node's PNNI topology database for a particular level in the PNNI -- hierarchy. mscARtgPnniTop OBJECT IDENTIFIER ::= { mscARtgPnni 4 } mscARtgPnniTopRowStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF MscARtgPnniTopRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "*** THIS TABLE CURRENTLY NOT IMPLEMENTED *** This entry controls the addition and deletion of mscARtgPnniTop components." ::= { mscARtgPnniTop 1 } mscARtgPnniTopRowStatusEntry OBJECT-TYPE SYNTAX MscARtgPnniTopRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A single entry in the table represents a single mscARtgPnniTop component." INDEX { mscARtgIndex, mscARtgPnniIndex, mscARtgPnniTopIndex } ::= { mscARtgPnniTopRowStatusTable 1 } MscARtgPnniTopRowStatusEntry ::= SEQUENCE { mscARtgPnniTopRowStatus RowStatus, mscARtgPnniTopComponentName DisplayString, mscARtgPnniTopStorageType StorageType, mscARtgPnniTopIndex Integer32 } mscARtgPnniTopRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-only STATUS mandatory DESCRIPTION "This variable is used as the basis for SNMP naming of mscARtgPnniTop components. These components cannot be added nor deleted." ::= { mscARtgPnniTopRowStatusEntry 1 } mscARtgPnniTopComponentName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This variable provides the component's string name for use with the ASCII Console Interface" ::= { mscARtgPnniTopRowStatusEntry 2 } mscARtgPnniTopStorageType OBJECT-TYPE SYNTAX StorageType ACCESS read-only STATUS mandatory DESCRIPTION "This variable represents the storage type value for the mscARtgPnniTop tables." ::= { mscARtgPnniTopRowStatusEntry 4 } mscARtgPnniTopIndex OBJECT-TYPE SYNTAX Integer32 (0..104) ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable represents the index for the mscARtgPnniTop tables." ::= { mscARtgPnniTopRowStatusEntry 10 } mscARtgPnniTopOperTable OBJECT-TYPE SYNTAX SEQUENCE OF MscARtgPnniTopOperEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "*** THIS TABLE CURRENTLY NOT IMPLEMENTED *** This group contains the operational attributes of a Topology component." ::= { mscARtgPnniTop 10 } mscARtgPnniTopOperEntry OBJECT-TYPE SYNTAX MscARtgPnniTopOperEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscARtgPnniTopOperTable." INDEX { mscARtgIndex, mscARtgPnniIndex, mscARtgPnniTopIndex } ::= { mscARtgPnniTopOperTable 1 } MscARtgPnniTopOperEntry ::= SEQUENCE { mscARtgPnniTopPtsesInDatabase Gauge32, mscARtgPnniTopPglNodeId HexString, mscARtgPnniTopActiveParentNodeId HexString, mscARtgPnniTopPreferredPglNodeId HexString } mscARtgPnniTopPtsesInDatabase OBJECT-TYPE SYNTAX Gauge32 (0..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the number of PTSEs in storage in this node's topology database for this level." ::= { mscARtgPnniTopOperEntry 1 } mscARtgPnniTopPglNodeId OBJECT-TYPE SYNTAX HexString (SIZE (0..22)) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the node id of the peer group leader. If this attribute is empty, it indicates the Peer Group Level node id is unknown." ::= { mscARtgPnniTopOperEntry 2 } mscARtgPnniTopActiveParentNodeId OBJECT-TYPE SYNTAX HexString (SIZE (0..22)) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the node identifier being used by the LGN representing this peer group at the next higher level peer group." ::= { mscARtgPnniTopOperEntry 3 } mscARtgPnniTopPreferredPglNodeId OBJECT-TYPE SYNTAX HexString (SIZE (0..22)) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute represents the node in database with the highest Peer Group Level (PGL) priority. If this attribute is empty, it indicates the preferred PGL node id is unknown." ::= { mscARtgPnniTopOperEntry 4 } -- -- *** THIS SUBTREE CURRENTLY NOT IMPLEMENTED *** -- -- ARtg Pnni Top/ Node/ -- This component represents the nodal information stored in this -- node's topology database. -- -- The reachable ATM end system addresses (both interior and -- exterior reachable addresses) advertised by the node can be listed -- through the Addr subcomponent instances. -- -- All advertised links associated with the node can be listed through -- the Link subcomponent instances which are indexed by their port id. mscARtgPnniTopNode OBJECT IDENTIFIER ::= { mscARtgPnniTop 2 } mscARtgPnniTopNodeRowStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF MscARtgPnniTopNodeRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "*** THIS TABLE CURRENTLY NOT IMPLEMENTED *** This entry controls the addition and deletion of mscARtgPnniTopNode components." ::= { mscARtgPnniTopNode 1 } mscARtgPnniTopNodeRowStatusEntry OBJECT-TYPE SYNTAX MscARtgPnniTopNodeRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A single entry in the table represents a single mscARtgPnniTopNode component." INDEX { mscARtgIndex, mscARtgPnniIndex, mscARtgPnniTopIndex, mscARtgPnniTopNodeIndex } ::= { mscARtgPnniTopNodeRowStatusTable 1 } MscARtgPnniTopNodeRowStatusEntry ::= SEQUENCE { mscARtgPnniTopNodeRowStatus RowStatus, mscARtgPnniTopNodeComponentName DisplayString, mscARtgPnniTopNodeStorageType StorageType, mscARtgPnniTopNodeIndex HexString } mscARtgPnniTopNodeRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-only STATUS mandatory DESCRIPTION "This variable is used as the basis for SNMP naming of mscARtgPnniTopNode components. These components cannot be added nor deleted." ::= { mscARtgPnniTopNodeRowStatusEntry 1 } mscARtgPnniTopNodeComponentName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This variable provides the component's string name for use with the ASCII Console Interface" ::= { mscARtgPnniTopNodeRowStatusEntry 2 } mscARtgPnniTopNodeStorageType OBJECT-TYPE SYNTAX StorageType ACCESS read-only STATUS mandatory DESCRIPTION "This variable represents the storage type value for the mscARtgPnniTopNode tables." ::= { mscARtgPnniTopNodeRowStatusEntry 4 } mscARtgPnniTopNodeIndex OBJECT-TYPE SYNTAX HexString (SIZE (22)) ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable represents the index for the mscARtgPnniTopNode tables." ::= { mscARtgPnniTopNodeRowStatusEntry 10 } -- -- *** THIS SUBTREE CURRENTLY NOT IMPLEMENTED *** -- -- ARtg Pnni Top Node/ Address/
, -- , -- This component represents an address advertised by the parent -- node. The instance value is a 38 hex digit string. -- -- The prefixLength specifies the number of significant bits in the -- address. -- -- The reachability specifies whether the address is internal or -- exterior. -- An internal reachable address is an address of a destination that is -- directly attached to the logical node advertising the address. An -- exterior reachable address is an address that can be reached -- through a PNNI routing domain, but which is not located in that -- PNNI routing domain. mscARtgPnniTopNodeAddr OBJECT IDENTIFIER ::= { mscARtgPnniTopNode 2 } mscARtgPnniTopNodeAddrRowStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF MscARtgPnniTopNodeAddrRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "*** THIS TABLE CURRENTLY NOT IMPLEMENTED *** This entry controls the addition and deletion of mscARtgPnniTopNodeAddr components." ::= { mscARtgPnniTopNodeAddr 1 } mscARtgPnniTopNodeAddrRowStatusEntry OBJECT-TYPE SYNTAX MscARtgPnniTopNodeAddrRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A single entry in the table represents a single mscARtgPnniTopNodeAddr component." INDEX { mscARtgIndex, mscARtgPnniIndex, mscARtgPnniTopIndex, mscARtgPnniTopNodeIndex, mscARtgPnniTopNodeAddrAddressIndex, mscARtgPnniTopNodeAddrPrefixLengthIndex, mscARtgPnniTopNodeAddrReachabilityIndex } ::= { mscARtgPnniTopNodeAddrRowStatusTable 1 } MscARtgPnniTopNodeAddrRowStatusEntry ::= SEQUENCE { mscARtgPnniTopNodeAddrRowStatus RowStatus, mscARtgPnniTopNodeAddrComponentName DisplayString, mscARtgPnniTopNodeAddrStorageType StorageType, mscARtgPnniTopNodeAddrAddressIndex HexString, mscARtgPnniTopNodeAddrPrefixLengthIndex Integer32, mscARtgPnniTopNodeAddrReachabilityIndex INTEGER } mscARtgPnniTopNodeAddrRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-only STATUS mandatory DESCRIPTION "This variable is used as the basis for SNMP naming of mscARtgPnniTopNodeAddr components. These components cannot be added nor deleted." ::= { mscARtgPnniTopNodeAddrRowStatusEntry 1 } mscARtgPnniTopNodeAddrComponentName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This variable provides the component's string name for use with the ASCII Console Interface" ::= { mscARtgPnniTopNodeAddrRowStatusEntry 2 } mscARtgPnniTopNodeAddrStorageType OBJECT-TYPE SYNTAX StorageType ACCESS read-only STATUS mandatory DESCRIPTION "This variable represents the storage type value for the mscARtgPnniTopNodeAddr tables." ::= { mscARtgPnniTopNodeAddrRowStatusEntry 4 } mscARtgPnniTopNodeAddrAddressIndex OBJECT-TYPE SYNTAX HexString (SIZE (19)) ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable represents an index for the mscARtgPnniTopNodeAddr tables." ::= { mscARtgPnniTopNodeAddrRowStatusEntry 10 } mscARtgPnniTopNodeAddrPrefixLengthIndex OBJECT-TYPE SYNTAX Integer32 (1..152) ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable represents an index for the mscARtgPnniTopNodeAddr tables." ::= { mscARtgPnniTopNodeAddrRowStatusEntry 11 } mscARtgPnniTopNodeAddrReachabilityIndex OBJECT-TYPE SYNTAX INTEGER { internal(0), exterior(1) } ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable represents an index for the mscARtgPnniTopNodeAddr tables." ::= { mscARtgPnniTopNodeAddrRowStatusEntry 12 } mscARtgPnniTopNodeAddrOperTable OBJECT-TYPE SYNTAX SEQUENCE OF MscARtgPnniTopNodeAddrOperEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "*** THIS TABLE CURRENTLY NOT IMPLEMENTED *** This attribute group contains the operational attributes for the Address component." ::= { mscARtgPnniTopNodeAddr 10 } mscARtgPnniTopNodeAddrOperEntry OBJECT-TYPE SYNTAX MscARtgPnniTopNodeAddrOperEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscARtgPnniTopNodeAddrOperTable." INDEX { mscARtgIndex, mscARtgPnniIndex, mscARtgPnniTopIndex, mscARtgPnniTopNodeIndex, mscARtgPnniTopNodeAddrAddressIndex, mscARtgPnniTopNodeAddrPrefixLengthIndex, mscARtgPnniTopNodeAddrReachabilityIndex } ::= { mscARtgPnniTopNodeAddrOperTable 1 } MscARtgPnniTopNodeAddrOperEntry ::= SEQUENCE { mscARtgPnniTopNodeAddrScope Unsigned32 } mscARtgPnniTopNodeAddrScope OBJECT-TYPE SYNTAX Unsigned32 (0..104) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute specifies the scope of the ATM address, which is the highest level to which this address will be advertised in the PNNI hierarchy." ::= { mscARtgPnniTopNodeAddrOperEntry 1 } -- -- *** THIS SUBTREE CURRENTLY NOT IMPLEMENTED *** -- -- ARtg Pnni Top/ Node/ Link/ -- This component represents the link information stored in this node's -- topology database. -- -- All advertised links associated with the node can be listed through -- the Link subcomponent instances which are indexed by their port id. mscARtgPnniTopNodeLink OBJECT IDENTIFIER ::= { mscARtgPnniTopNode 3 } mscARtgPnniTopNodeLinkRowStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF MscARtgPnniTopNodeLinkRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "*** THIS TABLE CURRENTLY NOT IMPLEMENTED *** This entry controls the addition and deletion of mscARtgPnniTopNodeLink components." ::= { mscARtgPnniTopNodeLink 1 } mscARtgPnniTopNodeLinkRowStatusEntry OBJECT-TYPE SYNTAX MscARtgPnniTopNodeLinkRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A single entry in the table represents a single mscARtgPnniTopNodeLink component." INDEX { mscARtgIndex, mscARtgPnniIndex, mscARtgPnniTopIndex, mscARtgPnniTopNodeIndex, mscARtgPnniTopNodeLinkIndex } ::= { mscARtgPnniTopNodeLinkRowStatusTable 1 } MscARtgPnniTopNodeLinkRowStatusEntry ::= SEQUENCE { mscARtgPnniTopNodeLinkRowStatus RowStatus, mscARtgPnniTopNodeLinkComponentName DisplayString, mscARtgPnniTopNodeLinkStorageType StorageType, mscARtgPnniTopNodeLinkIndex Integer32 } mscARtgPnniTopNodeLinkRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-only STATUS mandatory DESCRIPTION "This variable is used as the basis for SNMP naming of mscARtgPnniTopNodeLink components. These components cannot be added nor deleted." ::= { mscARtgPnniTopNodeLinkRowStatusEntry 1 } mscARtgPnniTopNodeLinkComponentName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This variable provides the component's string name for use with the ASCII Console Interface" ::= { mscARtgPnniTopNodeLinkRowStatusEntry 2 } mscARtgPnniTopNodeLinkStorageType OBJECT-TYPE SYNTAX StorageType ACCESS read-only STATUS mandatory DESCRIPTION "This variable represents the storage type value for the mscARtgPnniTopNodeLink tables." ::= { mscARtgPnniTopNodeLinkRowStatusEntry 4 } mscARtgPnniTopNodeLinkIndex OBJECT-TYPE SYNTAX Integer32 (0..268435455) ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable represents the index for the mscARtgPnniTopNodeLink tables." ::= { mscARtgPnniTopNodeLinkRowStatusEntry 10 } mscARtgPnniTopNodeLinkOperTable OBJECT-TYPE SYNTAX SEQUENCE OF MscARtgPnniTopNodeLinkOperEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "*** THIS TABLE CURRENTLY NOT IMPLEMENTED *** This group contains the operational attributes of a Link component." ::= { mscARtgPnniTopNodeLink 10 } mscARtgPnniTopNodeLinkOperEntry OBJECT-TYPE SYNTAX MscARtgPnniTopNodeLinkOperEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscARtgPnniTopNodeLinkOperTable." INDEX { mscARtgIndex, mscARtgPnniIndex, mscARtgPnniTopIndex, mscARtgPnniTopNodeIndex, mscARtgPnniTopNodeLinkIndex } ::= { mscARtgPnniTopNodeLinkOperTable 1 } MscARtgPnniTopNodeLinkOperEntry ::= SEQUENCE { mscARtgPnniTopNodeLinkRemoteNodeId HexString, mscARtgPnniTopNodeLinkRemotePortId Unsigned32 } mscARtgPnniTopNodeLinkRemoteNodeId OBJECT-TYPE SYNTAX HexString (SIZE (22)) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the id of the node at the far end of this link." ::= { mscARtgPnniTopNodeLinkOperEntry 1 } mscARtgPnniTopNodeLinkRemotePortId OBJECT-TYPE SYNTAX Unsigned32 (0..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the node's port id at the far end of this link." ::= { mscARtgPnniTopNodeLinkOperEntry 2 } -- -- *** THIS SUBTREE CURRENTLY NOT IMPLEMENTED *** -- -- ARtg Pnni Port/ -- This component represents a port advertised within the PNNI -- routing domain. mscARtgPnniPort OBJECT IDENTIFIER ::= { mscARtgPnni 5 } mscARtgPnniPortRowStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF MscARtgPnniPortRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "*** THIS TABLE CURRENTLY NOT IMPLEMENTED *** This entry controls the addition and deletion of mscARtgPnniPort components." ::= { mscARtgPnniPort 1 } mscARtgPnniPortRowStatusEntry OBJECT-TYPE SYNTAX MscARtgPnniPortRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A single entry in the table represents a single mscARtgPnniPort component." INDEX { mscARtgIndex, mscARtgPnniIndex, mscARtgPnniPortIndex } ::= { mscARtgPnniPortRowStatusTable 1 } MscARtgPnniPortRowStatusEntry ::= SEQUENCE { mscARtgPnniPortRowStatus RowStatus, mscARtgPnniPortComponentName DisplayString, mscARtgPnniPortStorageType StorageType, mscARtgPnniPortIndex Integer32 } mscARtgPnniPortRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-only STATUS mandatory DESCRIPTION "This variable is used as the basis for SNMP naming of mscARtgPnniPort components. These components cannot be added nor deleted." ::= { mscARtgPnniPortRowStatusEntry 1 } mscARtgPnniPortComponentName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This variable provides the component's string name for use with the ASCII Console Interface" ::= { mscARtgPnniPortRowStatusEntry 2 } mscARtgPnniPortStorageType OBJECT-TYPE SYNTAX StorageType ACCESS read-only STATUS mandatory DESCRIPTION "This variable represents the storage type value for the mscARtgPnniPort tables." ::= { mscARtgPnniPortRowStatusEntry 4 } mscARtgPnniPortIndex OBJECT-TYPE SYNTAX Integer32 (0..268435455) ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable represents the index for the mscARtgPnniPort tables." ::= { mscARtgPnniPortRowStatusEntry 10 } mscARtgPnniPortOperTable OBJECT-TYPE SYNTAX SEQUENCE OF MscARtgPnniPortOperEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "*** THIS TABLE CURRENTLY NOT IMPLEMENTED *** This group contains the operational attributes of a Port component." ::= { mscARtgPnniPort 10 } mscARtgPnniPortOperEntry OBJECT-TYPE SYNTAX MscARtgPnniPortOperEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscARtgPnniPortOperTable." INDEX { mscARtgIndex, mscARtgPnniIndex, mscARtgPnniPortIndex } ::= { mscARtgPnniPortOperTable 1 } MscARtgPnniPortOperEntry ::= SEQUENCE { mscARtgPnniPortStdComponentName RowPointer } mscARtgPnniPortStdComponentName OBJECT-TYPE SYNTAX RowPointer ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the component name of the port." ::= { mscARtgPnniPortOperEntry 1 } -- AtmCallRouter -- This component represents the database that contains all the static -- (provisioned) DNAs and dynamically registered DNAs (via ILMI) -- used for source call routing for ATM switched connection setups.. mscAtmCR OBJECT IDENTIFIER ::= { mscComponents 113 } mscAtmCRRowStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF MscAtmCRRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This entry controls the addition and deletion of mscAtmCR components." ::= { mscAtmCR 1 } mscAtmCRRowStatusEntry OBJECT-TYPE SYNTAX MscAtmCRRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A single entry in the table represents a single mscAtmCR component." INDEX { mscAtmCRIndex } ::= { mscAtmCRRowStatusTable 1 } MscAtmCRRowStatusEntry ::= SEQUENCE { mscAtmCRRowStatus RowStatus, mscAtmCRComponentName DisplayString, mscAtmCRStorageType StorageType, mscAtmCRIndex NonReplicated } mscAtmCRRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-write STATUS mandatory DESCRIPTION "This variable is used as the basis for SNMP naming of mscAtmCR components. These components can be added and deleted." ::= { mscAtmCRRowStatusEntry 1 } mscAtmCRComponentName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This variable provides the component's string name for use with the ASCII Console Interface" ::= { mscAtmCRRowStatusEntry 2 } mscAtmCRStorageType OBJECT-TYPE SYNTAX StorageType ACCESS read-only STATUS mandatory DESCRIPTION "This variable represents the storage type value for the mscAtmCR tables." ::= { mscAtmCRRowStatusEntry 4 } mscAtmCRIndex OBJECT-TYPE SYNTAX NonReplicated ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable represents the index for the mscAtmCR tables." ::= { mscAtmCRRowStatusEntry 10 } mscAtmCRProvTable OBJECT-TYPE SYNTAX SEQUENCE OF MscAtmCRProvEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This group represents the provisioned attributes for the AtmCallRouter component." ::= { mscAtmCR 10 } mscAtmCRProvEntry OBJECT-TYPE SYNTAX MscAtmCRProvEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscAtmCRProvTable." INDEX { mscAtmCRIndex } ::= { mscAtmCRProvTable 1 } MscAtmCRProvEntry ::= SEQUENCE { mscAtmCRNodeAddress AsciiString } mscAtmCRNodeAddress OBJECT-TYPE SYNTAX AsciiString (SIZE (26)) ACCESS read-write STATUS obsolete DESCRIPTION "This attribute specifies the NSAP address prefix used for ILMI purposes." ::= { mscAtmCRProvEntry 1 } mscAtmCRStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF MscAtmCRStatsEntry ACCESS not-accessible STATUS obsolete DESCRIPTION "This group represents the operational attributes for the AtmCallRouter component." ::= { mscAtmCR 11 } mscAtmCRStatsEntry OBJECT-TYPE SYNTAX MscAtmCRStatsEntry ACCESS not-accessible STATUS obsolete DESCRIPTION "An entry in the mscAtmCRStatsTable." INDEX { mscAtmCRIndex } ::= { mscAtmCRStatsTable 1 } MscAtmCRStatsEntry ::= SEQUENCE { mscAtmCRCallsRouted Counter32, mscAtmCRCallsFailed Counter32 } mscAtmCRCallsRouted OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS obsolete DESCRIPTION "This attribute counts the total number of calls routed." ::= { mscAtmCRStatsEntry 1 } mscAtmCRCallsFailed OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS obsolete DESCRIPTION "This attribute specifies the number of calls that failed to route." ::= { mscAtmCRStatsEntry 2 } -- -- *** THIS SUBTREE CURRENTLY NOT IMPLEMENTED *** -- -- AtmCallRouter AtmDna/ -- This component represents an ATM NSAP address that has been -- provisioned or dynamically registered via ILMI. mscAtmCRDna OBJECT IDENTIFIER ::= { mscAtmCR 2 } mscAtmCRDnaRowStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF MscAtmCRDnaRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "*** THIS TABLE CURRENTLY NOT IMPLEMENTED *** This entry controls the addition and deletion of mscAtmCRDna components." ::= { mscAtmCRDna 1 } mscAtmCRDnaRowStatusEntry OBJECT-TYPE SYNTAX MscAtmCRDnaRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A single entry in the table represents a single mscAtmCRDna component." INDEX { mscAtmCRIndex, mscAtmCRDnaIndex } ::= { mscAtmCRDnaRowStatusTable 1 } MscAtmCRDnaRowStatusEntry ::= SEQUENCE { mscAtmCRDnaRowStatus RowStatus, mscAtmCRDnaComponentName DisplayString, mscAtmCRDnaStorageType StorageType, mscAtmCRDnaIndex AsciiStringIndex } mscAtmCRDnaRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-only STATUS mandatory DESCRIPTION "This variable is used as the basis for SNMP naming of mscAtmCRDna components. These components cannot be added nor deleted." ::= { mscAtmCRDnaRowStatusEntry 1 } mscAtmCRDnaComponentName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This variable provides the component's string name for use with the ASCII Console Interface" ::= { mscAtmCRDnaRowStatusEntry 2 } mscAtmCRDnaStorageType OBJECT-TYPE SYNTAX StorageType ACCESS read-only STATUS mandatory DESCRIPTION "This variable represents the storage type value for the mscAtmCRDna tables." ::= { mscAtmCRDnaRowStatusEntry 4 } mscAtmCRDnaIndex OBJECT-TYPE SYNTAX AsciiStringIndex (SIZE (1..40)) ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable represents the index for the mscAtmCRDna tables." ::= { mscAtmCRDnaRowStatusEntry 10 } mscAtmCRDnaDestinationNameTable OBJECT-TYPE SYNTAX SEQUENCE OF MscAtmCRDnaDestinationNameEntry ACCESS not-accessible STATUS obsolete DESCRIPTION "*** THIS TABLE CURRENTLY NOT IMPLEMENTED *** This attribute indicates which components have this address provisioned or dynamically registered via ILMI." ::= { mscAtmCRDna 289 } mscAtmCRDnaDestinationNameEntry OBJECT-TYPE SYNTAX MscAtmCRDnaDestinationNameEntry ACCESS not-accessible STATUS obsolete DESCRIPTION "An entry in the mscAtmCRDnaDestinationNameTable." INDEX { mscAtmCRIndex, mscAtmCRDnaIndex, mscAtmCRDnaDestinationNameValue } ::= { mscAtmCRDnaDestinationNameTable 1 } MscAtmCRDnaDestinationNameEntry ::= SEQUENCE { mscAtmCRDnaDestinationNameValue RowPointer } mscAtmCRDnaDestinationNameValue OBJECT-TYPE SYNTAX RowPointer ACCESS read-only STATUS obsolete DESCRIPTION "This variable represents both the value and the index for the mscAtmCRDnaDestinationNameTable." ::= { mscAtmCRDnaDestinationNameEntry 1 } -- AtmIf/n Vpc/vpi SourcePvp -- This component represents the source end of a soft PVP. mscAtmIfVpcSrc OBJECT IDENTIFIER ::= { mscAtmIfVpc 6 } mscAtmIfVpcSrcRowStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF MscAtmIfVpcSrcRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This entry controls the addition and deletion of mscAtmIfVpcSrc components." ::= { mscAtmIfVpcSrc 1 } mscAtmIfVpcSrcRowStatusEntry OBJECT-TYPE SYNTAX MscAtmIfVpcSrcRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A single entry in the table represents a single mscAtmIfVpcSrc component." INDEX { mscAtmIfIndex, mscAtmIfVpcIndex, mscAtmIfVpcSrcIndex } ::= { mscAtmIfVpcSrcRowStatusTable 1 } MscAtmIfVpcSrcRowStatusEntry ::= SEQUENCE { mscAtmIfVpcSrcRowStatus RowStatus, mscAtmIfVpcSrcComponentName DisplayString, mscAtmIfVpcSrcStorageType StorageType, mscAtmIfVpcSrcIndex NonReplicated } mscAtmIfVpcSrcRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-write STATUS mandatory DESCRIPTION "This variable is used as the basis for SNMP naming of mscAtmIfVpcSrc components. These components can be added and deleted." ::= { mscAtmIfVpcSrcRowStatusEntry 1 } mscAtmIfVpcSrcComponentName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This variable provides the component's string name for use with the ASCII Console Interface" ::= { mscAtmIfVpcSrcRowStatusEntry 2 } mscAtmIfVpcSrcStorageType OBJECT-TYPE SYNTAX StorageType ACCESS read-only STATUS mandatory DESCRIPTION "This variable represents the storage type value for the mscAtmIfVpcSrc tables." ::= { mscAtmIfVpcSrcRowStatusEntry 4 } mscAtmIfVpcSrcIndex OBJECT-TYPE SYNTAX NonReplicated ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable represents the index for the mscAtmIfVpcSrc tables." ::= { mscAtmIfVpcSrcRowStatusEntry 10 } mscAtmIfVpcSrcProvTable OBJECT-TYPE SYNTAX SEQUENCE OF MscAtmIfVpcSrcProvEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This attribute group contains the provisionable attributes of the AtmIf/n Vpc/vpi SrcPvp component." ::= { mscAtmIfVpcSrc 10 } mscAtmIfVpcSrcProvEntry OBJECT-TYPE SYNTAX MscAtmIfVpcSrcProvEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscAtmIfVpcSrcProvTable." INDEX { mscAtmIfIndex, mscAtmIfVpcIndex, mscAtmIfVpcSrcIndex } ::= { mscAtmIfVpcSrcProvTable 1 } MscAtmIfVpcSrcProvEntry ::= SEQUENCE { mscAtmIfVpcSrcCallingAddress HexString, mscAtmIfVpcSrcCalledAddress HexString, mscAtmIfVpcSrcCalledVpi Unsigned32 } mscAtmIfVpcSrcCallingAddress OBJECT-TYPE SYNTAX HexString (SIZE (0..20)) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the calling address of the soft PVP. If it is a null string, then the calling address is the address of the current interface (that is, where the soft PVC originates)." DEFVAL { ''H } -- "" ::= { mscAtmIfVpcSrcProvEntry 1 } mscAtmIfVpcSrcCalledAddress OBJECT-TYPE SYNTAX HexString (SIZE (20)) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the called (remote) address of the soft PVP." ::= { mscAtmIfVpcSrcProvEntry 2 } mscAtmIfVpcSrcCalledVpi OBJECT-TYPE SYNTAX Unsigned32 (1..4095) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the called VPI of the soft PVP." ::= { mscAtmIfVpcSrcProvEntry 3 } mscAtmIfVpcSrcOperTable OBJECT-TYPE SYNTAX SEQUENCE OF MscAtmIfVpcSrcOperEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This attribute group contains the operational attributes associated with the SrcPvp or SrcPvc component." ::= { mscAtmIfVpcSrc 11 } mscAtmIfVpcSrcOperEntry OBJECT-TYPE SYNTAX MscAtmIfVpcSrcOperEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscAtmIfVpcSrcOperTable." INDEX { mscAtmIfIndex, mscAtmIfVpcIndex, mscAtmIfVpcSrcIndex } ::= { mscAtmIfVpcSrcOperTable 1 } MscAtmIfVpcSrcOperEntry ::= SEQUENCE { mscAtmIfVpcSrcState INTEGER, mscAtmIfVpcSrcRetryCount Counter32, mscAtmIfVpcSrcLastFailureCauseCode Unsigned32, mscAtmIfVpcSrcLastFailureDiagCode AsciiString } mscAtmIfVpcSrcState OBJECT-TYPE SYNTAX INTEGER { active(0), inactive(1) } ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the state of the soft PVP or soft PVC." ::= { mscAtmIfVpcSrcOperEntry 1 } mscAtmIfVpcSrcRetryCount OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the number of failed attempts to set up the soft PVP or soft PVC since the last time the connection failed." ::= { mscAtmIfVpcSrcOperEntry 2 } mscAtmIfVpcSrcLastFailureCauseCode OBJECT-TYPE SYNTAX Unsigned32 (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute contains the cause code in the last transmitted signalling message that contains the CAUSE information element. The cause code is used to describe the reason for generating certain signalling messages. The default value for this attribute is set to 0." ::= { mscAtmIfVpcSrcOperEntry 3 } mscAtmIfVpcSrcLastFailureDiagCode OBJECT-TYPE SYNTAX AsciiString (SIZE (0..8)) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute contains the diagnostic code in the last transmitted signalling message. The diagnostic code is contained in the CAUSE information element and identifies an information element type or timer type. The diagnostic code is present only if a procedural error is detected by the signalling protocol. A diagnostic code is always accompanied by the cause code. If there is no failure, this attribute is set to NULL." ::= { mscAtmIfVpcSrcOperEntry 4 } -- AtmIf/n Vpc/vpi Rp -- AtmIf/n Vcc/vpi.vci Rp -- AtmIf/n Vpt/vpi Vcc/vci Rp -- -- The RelayPoint component is used to establish a single hop of a -- Switched connection. When linked together, two Rps within a -- module, the associated connections are configured to relay ATM -- cells to one another. mscAtmIfVpcRp OBJECT IDENTIFIER ::= { mscAtmIfVpc 7 } mscAtmIfVpcRpRowStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF MscAtmIfVpcRpRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This entry controls the addition and deletion of mscAtmIfVpcRp components." ::= { mscAtmIfVpcRp 1 } mscAtmIfVpcRpRowStatusEntry OBJECT-TYPE SYNTAX MscAtmIfVpcRpRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A single entry in the table represents a single mscAtmIfVpcRp component." INDEX { mscAtmIfIndex, mscAtmIfVpcIndex, mscAtmIfVpcRpIndex } ::= { mscAtmIfVpcRpRowStatusTable 1 } MscAtmIfVpcRpRowStatusEntry ::= SEQUENCE { mscAtmIfVpcRpRowStatus RowStatus, mscAtmIfVpcRpComponentName DisplayString, mscAtmIfVpcRpStorageType StorageType, mscAtmIfVpcRpIndex NonReplicated } mscAtmIfVpcRpRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-only STATUS mandatory DESCRIPTION "This variable is used as the basis for SNMP naming of mscAtmIfVpcRp components. These components cannot be added nor deleted." ::= { mscAtmIfVpcRpRowStatusEntry 1 } mscAtmIfVpcRpComponentName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This variable provides the component's string name for use with the ASCII Console Interface" ::= { mscAtmIfVpcRpRowStatusEntry 2 } mscAtmIfVpcRpStorageType OBJECT-TYPE SYNTAX StorageType ACCESS read-only STATUS mandatory DESCRIPTION "This variable represents the storage type value for the mscAtmIfVpcRp tables." ::= { mscAtmIfVpcRpRowStatusEntry 4 } mscAtmIfVpcRpIndex OBJECT-TYPE SYNTAX NonReplicated ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable represents the index for the mscAtmIfVpcRp tables." ::= { mscAtmIfVpcRpRowStatusEntry 10 } mscAtmIfVpcRpOperTable OBJECT-TYPE SYNTAX SEQUENCE OF MscAtmIfVpcRpOperEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This attribute group contains the operational attributes for the AtmRelayPoint component." ::= { mscAtmIfVpcRp 10 } mscAtmIfVpcRpOperEntry OBJECT-TYPE SYNTAX MscAtmIfVpcRpOperEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscAtmIfVpcRpOperTable." INDEX { mscAtmIfIndex, mscAtmIfVpcIndex, mscAtmIfVpcRpIndex } ::= { mscAtmIfVpcRpOperTable 1 } MscAtmIfVpcRpOperEntry ::= SEQUENCE { mscAtmIfVpcRpNextHop RowPointer } mscAtmIfVpcRpNextHop OBJECT-TYPE SYNTAX RowPointer ACCESS read-only STATUS obsolete DESCRIPTION "This attribute indicates the component name of the Rp component with which this Rp component is associated." ::= { mscAtmIfVpcRpOperEntry 1 } mscAtmIfVpcRpNextHopsTable OBJECT-TYPE SYNTAX SEQUENCE OF MscAtmIfVpcRpNextHopsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This attribute indicates the component name(s) of the Rp component(s) with which this Rp component is associated. This attribute can have more than one component name only when the Vcc distributionType is pointToMultipoint and the callDirection is fromLink." ::= { mscAtmIfVpcRp 430 } mscAtmIfVpcRpNextHopsEntry OBJECT-TYPE SYNTAX MscAtmIfVpcRpNextHopsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscAtmIfVpcRpNextHopsTable." INDEX { mscAtmIfIndex, mscAtmIfVpcIndex, mscAtmIfVpcRpIndex, mscAtmIfVpcRpNextHopsValue } ::= { mscAtmIfVpcRpNextHopsTable 1 } MscAtmIfVpcRpNextHopsEntry ::= SEQUENCE { mscAtmIfVpcRpNextHopsValue RowPointer } mscAtmIfVpcRpNextHopsValue OBJECT-TYPE SYNTAX RowPointer ACCESS read-only STATUS mandatory DESCRIPTION "This variable represents both the value and the index for the mscAtmIfVpcRpNextHopsTable." ::= { mscAtmIfVpcRpNextHopsEntry 1 } -- AtmIf/n Vpc/vpi DestinationPvp -- This component represents the destination end of a soft PVP. mscAtmIfVpcDst OBJECT IDENTIFIER ::= { mscAtmIfVpc 8 } mscAtmIfVpcDstRowStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF MscAtmIfVpcDstRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This entry controls the addition and deletion of mscAtmIfVpcDst components." ::= { mscAtmIfVpcDst 1 } mscAtmIfVpcDstRowStatusEntry OBJECT-TYPE SYNTAX MscAtmIfVpcDstRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A single entry in the table represents a single mscAtmIfVpcDst component." INDEX { mscAtmIfIndex, mscAtmIfVpcIndex, mscAtmIfVpcDstIndex } ::= { mscAtmIfVpcDstRowStatusTable 1 } MscAtmIfVpcDstRowStatusEntry ::= SEQUENCE { mscAtmIfVpcDstRowStatus RowStatus, mscAtmIfVpcDstComponentName DisplayString, mscAtmIfVpcDstStorageType StorageType, mscAtmIfVpcDstIndex NonReplicated } mscAtmIfVpcDstRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-only STATUS mandatory DESCRIPTION "This variable is used as the basis for SNMP naming of mscAtmIfVpcDst components. These components cannot be added nor deleted." ::= { mscAtmIfVpcDstRowStatusEntry 1 } mscAtmIfVpcDstComponentName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This variable provides the component's string name for use with the ASCII Console Interface" ::= { mscAtmIfVpcDstRowStatusEntry 2 } mscAtmIfVpcDstStorageType OBJECT-TYPE SYNTAX StorageType ACCESS read-only STATUS mandatory DESCRIPTION "This variable represents the storage type value for the mscAtmIfVpcDst tables." ::= { mscAtmIfVpcDstRowStatusEntry 4 } mscAtmIfVpcDstIndex OBJECT-TYPE SYNTAX NonReplicated ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable represents the index for the mscAtmIfVpcDst tables." ::= { mscAtmIfVpcDstRowStatusEntry 10 } mscAtmIfVpcDstOperTable OBJECT-TYPE SYNTAX SEQUENCE OF MscAtmIfVpcDstOperEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This attribute group contains the operational attributes for the AtmIf/n Vpc/vpi DstPvp component." ::= { mscAtmIfVpcDst 10 } mscAtmIfVpcDstOperEntry OBJECT-TYPE SYNTAX MscAtmIfVpcDstOperEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscAtmIfVpcDstOperTable." INDEX { mscAtmIfIndex, mscAtmIfVpcIndex, mscAtmIfVpcDstIndex } ::= { mscAtmIfVpcDstOperTable 1 } MscAtmIfVpcDstOperEntry ::= SEQUENCE { mscAtmIfVpcDstCalledAddress HexString, mscAtmIfVpcDstCallingAddress AsciiString, mscAtmIfVpcDstCallingVpi AsciiString } mscAtmIfVpcDstCalledAddress OBJECT-TYPE SYNTAX HexString (SIZE (20)) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the called address of the soft PVP." ::= { mscAtmIfVpcDstOperEntry 1 } mscAtmIfVpcDstCallingAddress OBJECT-TYPE SYNTAX AsciiString (SIZE (7..40)) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the calling (remote) address of the soft PVP. If the address in not known, then the value of this address is Unknown." ::= { mscAtmIfVpcDstOperEntry 2 } mscAtmIfVpcDstCallingVpi OBJECT-TYPE SYNTAX AsciiString (SIZE (1..7)) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute represents the calling (remote) VPI of the soft PVP. If the VPI value is not known, the attribute value is set to Unknown." ::= { mscAtmIfVpcDstOperEntry 3 } -- AtmIf/n Vcc/vpi.vci SrcPvc -- AtmIf/n Vpt/vpi Vcc/vci SrcPvc -- -- This component represents the source end of a soft PVC. mscAtmIfVccSrc OBJECT IDENTIFIER ::= { mscAtmIfVcc 8 } mscAtmIfVccSrcRowStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF MscAtmIfVccSrcRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This entry controls the addition and deletion of mscAtmIfVccSrc components." ::= { mscAtmIfVccSrc 1 } mscAtmIfVccSrcRowStatusEntry OBJECT-TYPE SYNTAX MscAtmIfVccSrcRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A single entry in the table represents a single mscAtmIfVccSrc component." INDEX { mscAtmIfIndex, mscAtmIfVccIndex, mscAtmIfVccSrcIndex } ::= { mscAtmIfVccSrcRowStatusTable 1 } MscAtmIfVccSrcRowStatusEntry ::= SEQUENCE { mscAtmIfVccSrcRowStatus RowStatus, mscAtmIfVccSrcComponentName DisplayString, mscAtmIfVccSrcStorageType StorageType, mscAtmIfVccSrcIndex NonReplicated } mscAtmIfVccSrcRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-write STATUS mandatory DESCRIPTION "This variable is used as the basis for SNMP naming of mscAtmIfVccSrc components. These components can be added and deleted." ::= { mscAtmIfVccSrcRowStatusEntry 1 } mscAtmIfVccSrcComponentName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This variable provides the component's string name for use with the ASCII Console Interface" ::= { mscAtmIfVccSrcRowStatusEntry 2 } mscAtmIfVccSrcStorageType OBJECT-TYPE SYNTAX StorageType ACCESS read-only STATUS mandatory DESCRIPTION "This variable represents the storage type value for the mscAtmIfVccSrc tables." ::= { mscAtmIfVccSrcRowStatusEntry 4 } mscAtmIfVccSrcIndex OBJECT-TYPE SYNTAX NonReplicated ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable represents the index for the mscAtmIfVccSrc tables." ::= { mscAtmIfVccSrcRowStatusEntry 10 } mscAtmIfVccSrcProvTable OBJECT-TYPE SYNTAX SEQUENCE OF MscAtmIfVccSrcProvEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This attribute group contains the provisionable attributes of the SourcePvc component." ::= { mscAtmIfVccSrc 10 } mscAtmIfVccSrcProvEntry OBJECT-TYPE SYNTAX MscAtmIfVccSrcProvEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscAtmIfVccSrcProvTable." INDEX { mscAtmIfIndex, mscAtmIfVccIndex, mscAtmIfVccSrcIndex } ::= { mscAtmIfVccSrcProvTable 1 } MscAtmIfVccSrcProvEntry ::= SEQUENCE { mscAtmIfVccSrcRemoteAddress HexString, mscAtmIfVccSrcRemoteVpiVci IntegerSequence, mscAtmIfVccSrcCallingAddress HexString, mscAtmIfVccSrcCalledAddress HexString, mscAtmIfVccSrcCalledVpiVci IntegerSequence } mscAtmIfVccSrcRemoteAddress OBJECT-TYPE SYNTAX HexString (SIZE (20)) ACCESS read-write STATUS obsolete DESCRIPTION "This attribute represents the remote address of the soft PVC." ::= { mscAtmIfVccSrcProvEntry 1 } mscAtmIfVccSrcRemoteVpiVci OBJECT-TYPE SYNTAX IntegerSequence (SIZE (3..9)) ACCESS read-write STATUS obsolete DESCRIPTION "This attribute represents the remote VPI and VCI of the soft PVC." ::= { mscAtmIfVccSrcProvEntry 2 } mscAtmIfVccSrcCallingAddress OBJECT-TYPE SYNTAX HexString (SIZE (0..20)) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute represents the calling address of the soft PVC. If it is a null string, then the calling address is the address of the current interface (that is, where the soft PVC originates)." DEFVAL { ''H } -- "" ::= { mscAtmIfVccSrcProvEntry 3 } mscAtmIfVccSrcCalledAddress OBJECT-TYPE SYNTAX HexString (SIZE (20)) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute represents the called (remote) address of the soft PVC." ::= { mscAtmIfVccSrcProvEntry 4 } mscAtmIfVccSrcCalledVpiVci OBJECT-TYPE SYNTAX IntegerSequence (SIZE (3..10)) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute represents the remote VPI and VCI of the soft PVC." ::= { mscAtmIfVccSrcProvEntry 5 } mscAtmIfVccSrcOperTable OBJECT-TYPE SYNTAX SEQUENCE OF MscAtmIfVccSrcOperEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This attribute group contains the operational attributes associated with the SrcPvp or SrcPvc component." ::= { mscAtmIfVccSrc 11 } mscAtmIfVccSrcOperEntry OBJECT-TYPE SYNTAX MscAtmIfVccSrcOperEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscAtmIfVccSrcOperTable." INDEX { mscAtmIfIndex, mscAtmIfVccIndex, mscAtmIfVccSrcIndex } ::= { mscAtmIfVccSrcOperTable 1 } MscAtmIfVccSrcOperEntry ::= SEQUENCE { mscAtmIfVccSrcState INTEGER, mscAtmIfVccSrcRetryCount Counter32, mscAtmIfVccSrcLastFailureCauseCode Unsigned32, mscAtmIfVccSrcLastFailureDiagCode AsciiString } mscAtmIfVccSrcState OBJECT-TYPE SYNTAX INTEGER { active(0), inactive(1) } ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the state of the soft PVP or soft PVC." ::= { mscAtmIfVccSrcOperEntry 1 } mscAtmIfVccSrcRetryCount OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the number of failed attempts to set up the soft PVP or soft PVC since the last time the connection failed." ::= { mscAtmIfVccSrcOperEntry 2 } mscAtmIfVccSrcLastFailureCauseCode OBJECT-TYPE SYNTAX Unsigned32 (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute contains the cause code in the last transmitted signalling message that contains the CAUSE information element. The cause code is used to describe the reason for generating certain signalling messages. The default value for this attribute is set to 0." ::= { mscAtmIfVccSrcOperEntry 3 } mscAtmIfVccSrcLastFailureDiagCode OBJECT-TYPE SYNTAX AsciiString (SIZE (0..8)) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute contains the diagnostic code in the last transmitted signalling message. The diagnostic code is contained in the CAUSE information element and identifies an information element type or timer type. The diagnostic code is present only if a procedural error is detected by the signalling protocol. A diagnostic code is always accompanied by the cause code. If there is no failure, this attribute is set to NULL." ::= { mscAtmIfVccSrcOperEntry 4 } -- AtmIf/n Vcc/vpi.vci Ep -- AtmIf/n Vpt/vpi Vcc/vci Ep -- -- The EndPoint component of the application associated with the -- VCC is used to link a switched VCC to an application that sends -- and receives frames using the connection. mscAtmIfVccEp OBJECT IDENTIFIER ::= { mscAtmIfVcc 9 } mscAtmIfVccEpRowStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF MscAtmIfVccEpRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This entry controls the addition and deletion of mscAtmIfVccEp components." ::= { mscAtmIfVccEp 1 } mscAtmIfVccEpRowStatusEntry OBJECT-TYPE SYNTAX MscAtmIfVccEpRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A single entry in the table represents a single mscAtmIfVccEp component." INDEX { mscAtmIfIndex, mscAtmIfVccIndex, mscAtmIfVccEpIndex } ::= { mscAtmIfVccEpRowStatusTable 1 } MscAtmIfVccEpRowStatusEntry ::= SEQUENCE { mscAtmIfVccEpRowStatus RowStatus, mscAtmIfVccEpComponentName DisplayString, mscAtmIfVccEpStorageType StorageType, mscAtmIfVccEpIndex NonReplicated } mscAtmIfVccEpRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-only STATUS mandatory DESCRIPTION "This variable is used as the basis for SNMP naming of mscAtmIfVccEp components. These components cannot be added nor deleted." ::= { mscAtmIfVccEpRowStatusEntry 1 } mscAtmIfVccEpComponentName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This variable provides the component's string name for use with the ASCII Console Interface" ::= { mscAtmIfVccEpRowStatusEntry 2 } mscAtmIfVccEpStorageType OBJECT-TYPE SYNTAX StorageType ACCESS read-only STATUS mandatory DESCRIPTION "This variable represents the storage type value for the mscAtmIfVccEp tables." ::= { mscAtmIfVccEpRowStatusEntry 4 } mscAtmIfVccEpIndex OBJECT-TYPE SYNTAX NonReplicated ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable represents the index for the mscAtmIfVccEp tables." ::= { mscAtmIfVccEpRowStatusEntry 10 } mscAtmIfVccEpOperTable OBJECT-TYPE SYNTAX SEQUENCE OF MscAtmIfVccEpOperEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This attribute group contains the operational attributes for the AtmEndPoint component." ::= { mscAtmIfVccEp 10 } mscAtmIfVccEpOperEntry OBJECT-TYPE SYNTAX MscAtmIfVccEpOperEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscAtmIfVccEpOperTable." INDEX { mscAtmIfIndex, mscAtmIfVccIndex, mscAtmIfVccEpIndex } ::= { mscAtmIfVccEpOperTable 1 } MscAtmIfVccEpOperEntry ::= SEQUENCE { mscAtmIfVccEpApplicationName RowPointer } mscAtmIfVccEpApplicationName OBJECT-TYPE SYNTAX RowPointer ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the component name associated with the application associated with the switched VCC." ::= { mscAtmIfVccEpOperEntry 1 } -- AtmIf/n Vpc/vpi Rp -- AtmIf/n Vcc/vpi.vci Rp -- AtmIf/n Vpt/vpi Vcc/vci Rp -- -- The RelayPoint component is used to establish a single hop of a -- Switched connection. When linked together, two Rps within a -- module, the associated connections are configured to relay ATM -- cells to one another. mscAtmIfVccRp OBJECT IDENTIFIER ::= { mscAtmIfVcc 10 } mscAtmIfVccRpRowStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF MscAtmIfVccRpRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This entry controls the addition and deletion of mscAtmIfVccRp components." ::= { mscAtmIfVccRp 1 } mscAtmIfVccRpRowStatusEntry OBJECT-TYPE SYNTAX MscAtmIfVccRpRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A single entry in the table represents a single mscAtmIfVccRp component." INDEX { mscAtmIfIndex, mscAtmIfVccIndex, mscAtmIfVccRpIndex } ::= { mscAtmIfVccRpRowStatusTable 1 } MscAtmIfVccRpRowStatusEntry ::= SEQUENCE { mscAtmIfVccRpRowStatus RowStatus, mscAtmIfVccRpComponentName DisplayString, mscAtmIfVccRpStorageType StorageType, mscAtmIfVccRpIndex NonReplicated } mscAtmIfVccRpRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-only STATUS mandatory DESCRIPTION "This variable is used as the basis for SNMP naming of mscAtmIfVccRp components. These components cannot be added nor deleted." ::= { mscAtmIfVccRpRowStatusEntry 1 } mscAtmIfVccRpComponentName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This variable provides the component's string name for use with the ASCII Console Interface" ::= { mscAtmIfVccRpRowStatusEntry 2 } mscAtmIfVccRpStorageType OBJECT-TYPE SYNTAX StorageType ACCESS read-only STATUS mandatory DESCRIPTION "This variable represents the storage type value for the mscAtmIfVccRp tables." ::= { mscAtmIfVccRpRowStatusEntry 4 } mscAtmIfVccRpIndex OBJECT-TYPE SYNTAX NonReplicated ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable represents the index for the mscAtmIfVccRp tables." ::= { mscAtmIfVccRpRowStatusEntry 10 } mscAtmIfVccRpOperTable OBJECT-TYPE SYNTAX SEQUENCE OF MscAtmIfVccRpOperEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This attribute group contains the operational attributes for the AtmRelayPoint component." ::= { mscAtmIfVccRp 10 } mscAtmIfVccRpOperEntry OBJECT-TYPE SYNTAX MscAtmIfVccRpOperEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscAtmIfVccRpOperTable." INDEX { mscAtmIfIndex, mscAtmIfVccIndex, mscAtmIfVccRpIndex } ::= { mscAtmIfVccRpOperTable 1 } MscAtmIfVccRpOperEntry ::= SEQUENCE { mscAtmIfVccRpNextHop RowPointer } mscAtmIfVccRpNextHop OBJECT-TYPE SYNTAX RowPointer ACCESS read-only STATUS obsolete DESCRIPTION "This attribute indicates the component name of the Rp component with which this Rp component is associated." ::= { mscAtmIfVccRpOperEntry 1 } mscAtmIfVccRpNextHopsTable OBJECT-TYPE SYNTAX SEQUENCE OF MscAtmIfVccRpNextHopsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This attribute indicates the component name(s) of the Rp component(s) with which this Rp component is associated. This attribute can have more than one component name only when the Vcc distributionType is pointToMultipoint and the callDirection is fromLink." ::= { mscAtmIfVccRp 430 } mscAtmIfVccRpNextHopsEntry OBJECT-TYPE SYNTAX MscAtmIfVccRpNextHopsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscAtmIfVccRpNextHopsTable." INDEX { mscAtmIfIndex, mscAtmIfVccIndex, mscAtmIfVccRpIndex, mscAtmIfVccRpNextHopsValue } ::= { mscAtmIfVccRpNextHopsTable 1 } MscAtmIfVccRpNextHopsEntry ::= SEQUENCE { mscAtmIfVccRpNextHopsValue RowPointer } mscAtmIfVccRpNextHopsValue OBJECT-TYPE SYNTAX RowPointer ACCESS read-only STATUS mandatory DESCRIPTION "This variable represents both the value and the index for the mscAtmIfVccRpNextHopsTable." ::= { mscAtmIfVccRpNextHopsEntry 1 } -- AtmIf/n Vcc/vpi.vci DstPvc -- AtmIf/n Vpt/vpi Vcc/vci DstPvc -- -- This component represents the destination end of a soft PVC. mscAtmIfVccDst OBJECT IDENTIFIER ::= { mscAtmIfVcc 11 } mscAtmIfVccDstRowStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF MscAtmIfVccDstRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This entry controls the addition and deletion of mscAtmIfVccDst components." ::= { mscAtmIfVccDst 1 } mscAtmIfVccDstRowStatusEntry OBJECT-TYPE SYNTAX MscAtmIfVccDstRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A single entry in the table represents a single mscAtmIfVccDst component." INDEX { mscAtmIfIndex, mscAtmIfVccIndex, mscAtmIfVccDstIndex } ::= { mscAtmIfVccDstRowStatusTable 1 } MscAtmIfVccDstRowStatusEntry ::= SEQUENCE { mscAtmIfVccDstRowStatus RowStatus, mscAtmIfVccDstComponentName DisplayString, mscAtmIfVccDstStorageType StorageType, mscAtmIfVccDstIndex NonReplicated } mscAtmIfVccDstRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-only STATUS mandatory DESCRIPTION "This variable is used as the basis for SNMP naming of mscAtmIfVccDst components. These components cannot be added nor deleted." ::= { mscAtmIfVccDstRowStatusEntry 1 } mscAtmIfVccDstComponentName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This variable provides the component's string name for use with the ASCII Console Interface" ::= { mscAtmIfVccDstRowStatusEntry 2 } mscAtmIfVccDstStorageType OBJECT-TYPE SYNTAX StorageType ACCESS read-only STATUS mandatory DESCRIPTION "This variable represents the storage type value for the mscAtmIfVccDst tables." ::= { mscAtmIfVccDstRowStatusEntry 4 } mscAtmIfVccDstIndex OBJECT-TYPE SYNTAX NonReplicated ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable represents the index for the mscAtmIfVccDst tables." ::= { mscAtmIfVccDstRowStatusEntry 10 } mscAtmIfVccDstOperTable OBJECT-TYPE SYNTAX SEQUENCE OF MscAtmIfVccDstOperEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This attribute group contains the operational attributes for the DestinationPvc component." ::= { mscAtmIfVccDst 10 } mscAtmIfVccDstOperEntry OBJECT-TYPE SYNTAX MscAtmIfVccDstOperEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscAtmIfVccDstOperTable." INDEX { mscAtmIfIndex, mscAtmIfVccIndex, mscAtmIfVccDstIndex } ::= { mscAtmIfVccDstOperTable 1 } MscAtmIfVccDstOperEntry ::= SEQUENCE { mscAtmIfVccDstCalledAddress HexString, mscAtmIfVccDstCallingAddress AsciiString, mscAtmIfVccDstCallingVpiVci AsciiString } mscAtmIfVccDstCalledAddress OBJECT-TYPE SYNTAX HexString (SIZE (20)) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute represents the called address of the soft PVC." ::= { mscAtmIfVccDstOperEntry 3 } mscAtmIfVccDstCallingAddress OBJECT-TYPE SYNTAX AsciiString (SIZE (7..40)) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute represents the remote address of the soft PVC. If the address in not known, then the value of this address is Unknown." ::= { mscAtmIfVccDstOperEntry 4 } mscAtmIfVccDstCallingVpiVci OBJECT-TYPE SYNTAX AsciiString (SIZE (7..9)) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute represents the remote VPI and VCI of the soft PVC. If the VPI and VCI values are not known, this attribute is set to Unknown." ::= { mscAtmIfVccDstOperEntry 5 } -- AtmIf/n Vcc/vpi.vci SrcPvc -- AtmIf/n Vpt/vpi Vcc/vci SrcPvc -- -- This component represents the source end of a soft PVC. mscAtmIfVptVccSrc OBJECT IDENTIFIER ::= { mscAtmIfVptVcc 8 } mscAtmIfVptVccSrcRowStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF MscAtmIfVptVccSrcRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This entry controls the addition and deletion of mscAtmIfVptVccSrc components." ::= { mscAtmIfVptVccSrc 1 } mscAtmIfVptVccSrcRowStatusEntry OBJECT-TYPE SYNTAX MscAtmIfVptVccSrcRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A single entry in the table represents a single mscAtmIfVptVccSrc component." INDEX { mscAtmIfIndex, mscAtmIfVptIndex, mscAtmIfVptVccIndex, mscAtmIfVptVccSrcIndex } ::= { mscAtmIfVptVccSrcRowStatusTable 1 } MscAtmIfVptVccSrcRowStatusEntry ::= SEQUENCE { mscAtmIfVptVccSrcRowStatus RowStatus, mscAtmIfVptVccSrcComponentName DisplayString, mscAtmIfVptVccSrcStorageType StorageType, mscAtmIfVptVccSrcIndex NonReplicated } mscAtmIfVptVccSrcRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-write STATUS mandatory DESCRIPTION "This variable is used as the basis for SNMP naming of mscAtmIfVptVccSrc components. These components can be added and deleted." ::= { mscAtmIfVptVccSrcRowStatusEntry 1 } mscAtmIfVptVccSrcComponentName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This variable provides the component's string name for use with the ASCII Console Interface" ::= { mscAtmIfVptVccSrcRowStatusEntry 2 } mscAtmIfVptVccSrcStorageType OBJECT-TYPE SYNTAX StorageType ACCESS read-only STATUS mandatory DESCRIPTION "This variable represents the storage type value for the mscAtmIfVptVccSrc tables." ::= { mscAtmIfVptVccSrcRowStatusEntry 4 } mscAtmIfVptVccSrcIndex OBJECT-TYPE SYNTAX NonReplicated ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable represents the index for the mscAtmIfVptVccSrc tables." ::= { mscAtmIfVptVccSrcRowStatusEntry 10 } mscAtmIfVptVccSrcProvTable OBJECT-TYPE SYNTAX SEQUENCE OF MscAtmIfVptVccSrcProvEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This attribute group contains the provisionable attributes of the SourcePvc component." ::= { mscAtmIfVptVccSrc 10 } mscAtmIfVptVccSrcProvEntry OBJECT-TYPE SYNTAX MscAtmIfVptVccSrcProvEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscAtmIfVptVccSrcProvTable." INDEX { mscAtmIfIndex, mscAtmIfVptIndex, mscAtmIfVptVccIndex, mscAtmIfVptVccSrcIndex } ::= { mscAtmIfVptVccSrcProvTable 1 } MscAtmIfVptVccSrcProvEntry ::= SEQUENCE { mscAtmIfVptVccSrcRemoteAddress HexString, mscAtmIfVptVccSrcRemoteVpiVci IntegerSequence, mscAtmIfVptVccSrcCallingAddress HexString, mscAtmIfVptVccSrcCalledAddress HexString, mscAtmIfVptVccSrcCalledVpiVci IntegerSequence } mscAtmIfVptVccSrcRemoteAddress OBJECT-TYPE SYNTAX HexString (SIZE (20)) ACCESS read-write STATUS obsolete DESCRIPTION "This attribute represents the remote address of the soft PVC." ::= { mscAtmIfVptVccSrcProvEntry 1 } mscAtmIfVptVccSrcRemoteVpiVci OBJECT-TYPE SYNTAX IntegerSequence (SIZE (3..9)) ACCESS read-write STATUS obsolete DESCRIPTION "This attribute represents the remote VPI and VCI of the soft PVC." ::= { mscAtmIfVptVccSrcProvEntry 2 } mscAtmIfVptVccSrcCallingAddress OBJECT-TYPE SYNTAX HexString (SIZE (0..20)) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute represents the calling address of the soft PVC. If it is a null string, then the calling address is the address of the current interface (that is, where the soft PVC originates)." DEFVAL { ''H } -- "" ::= { mscAtmIfVptVccSrcProvEntry 3 } mscAtmIfVptVccSrcCalledAddress OBJECT-TYPE SYNTAX HexString (SIZE (20)) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute represents the called (remote) address of the soft PVC." ::= { mscAtmIfVptVccSrcProvEntry 4 } mscAtmIfVptVccSrcCalledVpiVci OBJECT-TYPE SYNTAX IntegerSequence (SIZE (3..10)) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute represents the remote VPI and VCI of the soft PVC." ::= { mscAtmIfVptVccSrcProvEntry 5 } mscAtmIfVptVccSrcOperTable OBJECT-TYPE SYNTAX SEQUENCE OF MscAtmIfVptVccSrcOperEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This attribute group contains the operational attributes associated with the SrcPvp or SrcPvc component." ::= { mscAtmIfVptVccSrc 11 } mscAtmIfVptVccSrcOperEntry OBJECT-TYPE SYNTAX MscAtmIfVptVccSrcOperEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscAtmIfVptVccSrcOperTable." INDEX { mscAtmIfIndex, mscAtmIfVptIndex, mscAtmIfVptVccIndex, mscAtmIfVptVccSrcIndex } ::= { mscAtmIfVptVccSrcOperTable 1 } MscAtmIfVptVccSrcOperEntry ::= SEQUENCE { mscAtmIfVptVccSrcState INTEGER, mscAtmIfVptVccSrcRetryCount Counter32, mscAtmIfVptVccSrcLastFailureCauseCode Unsigned32, mscAtmIfVptVccSrcLastFailureDiagCode AsciiString } mscAtmIfVptVccSrcState OBJECT-TYPE SYNTAX INTEGER { active(0), inactive(1) } ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the state of the soft PVP or soft PVC." ::= { mscAtmIfVptVccSrcOperEntry 1 } mscAtmIfVptVccSrcRetryCount OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the number of failed attempts to set up the soft PVP or soft PVC since the last time the connection failed." ::= { mscAtmIfVptVccSrcOperEntry 2 } mscAtmIfVptVccSrcLastFailureCauseCode OBJECT-TYPE SYNTAX Unsigned32 (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute contains the cause code in the last transmitted signalling message that contains the CAUSE information element. The cause code is used to describe the reason for generating certain signalling messages. The default value for this attribute is set to 0." ::= { mscAtmIfVptVccSrcOperEntry 3 } mscAtmIfVptVccSrcLastFailureDiagCode OBJECT-TYPE SYNTAX AsciiString (SIZE (0..8)) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute contains the diagnostic code in the last transmitted signalling message. The diagnostic code is contained in the CAUSE information element and identifies an information element type or timer type. The diagnostic code is present only if a procedural error is detected by the signalling protocol. A diagnostic code is always accompanied by the cause code. If there is no failure, this attribute is set to NULL." ::= { mscAtmIfVptVccSrcOperEntry 4 } -- AtmIf/n Vcc/vpi.vci Ep -- AtmIf/n Vpt/vpi Vcc/vci Ep -- -- The EndPoint component of the application associated with the -- VCC is used to link a switched VCC to an application that sends -- and receives frames using the connection. mscAtmIfVptVccEp OBJECT IDENTIFIER ::= { mscAtmIfVptVcc 9 } mscAtmIfVptVccEpRowStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF MscAtmIfVptVccEpRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This entry controls the addition and deletion of mscAtmIfVptVccEp components." ::= { mscAtmIfVptVccEp 1 } mscAtmIfVptVccEpRowStatusEntry OBJECT-TYPE SYNTAX MscAtmIfVptVccEpRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A single entry in the table represents a single mscAtmIfVptVccEp component." INDEX { mscAtmIfIndex, mscAtmIfVptIndex, mscAtmIfVptVccIndex, mscAtmIfVptVccEpIndex } ::= { mscAtmIfVptVccEpRowStatusTable 1 } MscAtmIfVptVccEpRowStatusEntry ::= SEQUENCE { mscAtmIfVptVccEpRowStatus RowStatus, mscAtmIfVptVccEpComponentName DisplayString, mscAtmIfVptVccEpStorageType StorageType, mscAtmIfVptVccEpIndex NonReplicated } mscAtmIfVptVccEpRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-only STATUS mandatory DESCRIPTION "This variable is used as the basis for SNMP naming of mscAtmIfVptVccEp components. These components cannot be added nor deleted." ::= { mscAtmIfVptVccEpRowStatusEntry 1 } mscAtmIfVptVccEpComponentName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This variable provides the component's string name for use with the ASCII Console Interface" ::= { mscAtmIfVptVccEpRowStatusEntry 2 } mscAtmIfVptVccEpStorageType OBJECT-TYPE SYNTAX StorageType ACCESS read-only STATUS mandatory DESCRIPTION "This variable represents the storage type value for the mscAtmIfVptVccEp tables." ::= { mscAtmIfVptVccEpRowStatusEntry 4 } mscAtmIfVptVccEpIndex OBJECT-TYPE SYNTAX NonReplicated ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable represents the index for the mscAtmIfVptVccEp tables." ::= { mscAtmIfVptVccEpRowStatusEntry 10 } mscAtmIfVptVccEpOperTable OBJECT-TYPE SYNTAX SEQUENCE OF MscAtmIfVptVccEpOperEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This attribute group contains the operational attributes for the AtmEndPoint component." ::= { mscAtmIfVptVccEp 10 } mscAtmIfVptVccEpOperEntry OBJECT-TYPE SYNTAX MscAtmIfVptVccEpOperEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscAtmIfVptVccEpOperTable." INDEX { mscAtmIfIndex, mscAtmIfVptIndex, mscAtmIfVptVccIndex, mscAtmIfVptVccEpIndex } ::= { mscAtmIfVptVccEpOperTable 1 } MscAtmIfVptVccEpOperEntry ::= SEQUENCE { mscAtmIfVptVccEpApplicationName RowPointer } mscAtmIfVptVccEpApplicationName OBJECT-TYPE SYNTAX RowPointer ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the component name associated with the application associated with the switched VCC." ::= { mscAtmIfVptVccEpOperEntry 1 } -- AtmIf/n Vpc/vpi Rp -- AtmIf/n Vcc/vpi.vci Rp -- AtmIf/n Vpt/vpi Vcc/vci Rp -- -- The RelayPoint component is used to establish a single hop of a -- Switched connection. When linked together, two Rps within a -- module, the associated connections are configured to relay ATM -- cells to one another. mscAtmIfVptVccRp OBJECT IDENTIFIER ::= { mscAtmIfVptVcc 10 } mscAtmIfVptVccRpRowStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF MscAtmIfVptVccRpRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This entry controls the addition and deletion of mscAtmIfVptVccRp components." ::= { mscAtmIfVptVccRp 1 } mscAtmIfVptVccRpRowStatusEntry OBJECT-TYPE SYNTAX MscAtmIfVptVccRpRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A single entry in the table represents a single mscAtmIfVptVccRp component." INDEX { mscAtmIfIndex, mscAtmIfVptIndex, mscAtmIfVptVccIndex, mscAtmIfVptVccRpIndex } ::= { mscAtmIfVptVccRpRowStatusTable 1 } MscAtmIfVptVccRpRowStatusEntry ::= SEQUENCE { mscAtmIfVptVccRpRowStatus RowStatus, mscAtmIfVptVccRpComponentName DisplayString, mscAtmIfVptVccRpStorageType StorageType, mscAtmIfVptVccRpIndex NonReplicated } mscAtmIfVptVccRpRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-only STATUS mandatory DESCRIPTION "This variable is used as the basis for SNMP naming of mscAtmIfVptVccRp components. These components cannot be added nor deleted." ::= { mscAtmIfVptVccRpRowStatusEntry 1 } mscAtmIfVptVccRpComponentName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This variable provides the component's string name for use with the ASCII Console Interface" ::= { mscAtmIfVptVccRpRowStatusEntry 2 } mscAtmIfVptVccRpStorageType OBJECT-TYPE SYNTAX StorageType ACCESS read-only STATUS mandatory DESCRIPTION "This variable represents the storage type value for the mscAtmIfVptVccRp tables." ::= { mscAtmIfVptVccRpRowStatusEntry 4 } mscAtmIfVptVccRpIndex OBJECT-TYPE SYNTAX NonReplicated ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable represents the index for the mscAtmIfVptVccRp tables." ::= { mscAtmIfVptVccRpRowStatusEntry 10 } mscAtmIfVptVccRpOperTable OBJECT-TYPE SYNTAX SEQUENCE OF MscAtmIfVptVccRpOperEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This attribute group contains the operational attributes for the AtmRelayPoint component." ::= { mscAtmIfVptVccRp 10 } mscAtmIfVptVccRpOperEntry OBJECT-TYPE SYNTAX MscAtmIfVptVccRpOperEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscAtmIfVptVccRpOperTable." INDEX { mscAtmIfIndex, mscAtmIfVptIndex, mscAtmIfVptVccIndex, mscAtmIfVptVccRpIndex } ::= { mscAtmIfVptVccRpOperTable 1 } MscAtmIfVptVccRpOperEntry ::= SEQUENCE { mscAtmIfVptVccRpNextHop RowPointer } mscAtmIfVptVccRpNextHop OBJECT-TYPE SYNTAX RowPointer ACCESS read-only STATUS obsolete DESCRIPTION "This attribute indicates the component name of the Rp component with which this Rp component is associated." ::= { mscAtmIfVptVccRpOperEntry 1 } mscAtmIfVptVccRpNextHopsTable OBJECT-TYPE SYNTAX SEQUENCE OF MscAtmIfVptVccRpNextHopsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This attribute indicates the component name(s) of the Rp component(s) with which this Rp component is associated. This attribute can have more than one component name only when the Vcc distributionType is pointToMultipoint and the callDirection is fromLink." ::= { mscAtmIfVptVccRp 430 } mscAtmIfVptVccRpNextHopsEntry OBJECT-TYPE SYNTAX MscAtmIfVptVccRpNextHopsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscAtmIfVptVccRpNextHopsTable." INDEX { mscAtmIfIndex, mscAtmIfVptIndex, mscAtmIfVptVccIndex, mscAtmIfVptVccRpIndex, mscAtmIfVptVccRpNextHopsValue } ::= { mscAtmIfVptVccRpNextHopsTable 1 } MscAtmIfVptVccRpNextHopsEntry ::= SEQUENCE { mscAtmIfVptVccRpNextHopsValue RowPointer } mscAtmIfVptVccRpNextHopsValue OBJECT-TYPE SYNTAX RowPointer ACCESS read-only STATUS mandatory DESCRIPTION "This variable represents both the value and the index for the mscAtmIfVptVccRpNextHopsTable." ::= { mscAtmIfVptVccRpNextHopsEntry 1 } -- AtmIf/n Vcc/vpi.vci DstPvc -- AtmIf/n Vpt/vpi Vcc/vci DstPvc -- -- This component represents the destination end of a soft PVC. mscAtmIfVptVccDst OBJECT IDENTIFIER ::= { mscAtmIfVptVcc 11 } mscAtmIfVptVccDstRowStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF MscAtmIfVptVccDstRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This entry controls the addition and deletion of mscAtmIfVptVccDst components." ::= { mscAtmIfVptVccDst 1 } mscAtmIfVptVccDstRowStatusEntry OBJECT-TYPE SYNTAX MscAtmIfVptVccDstRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A single entry in the table represents a single mscAtmIfVptVccDst component." INDEX { mscAtmIfIndex, mscAtmIfVptIndex, mscAtmIfVptVccIndex, mscAtmIfVptVccDstIndex } ::= { mscAtmIfVptVccDstRowStatusTable 1 } MscAtmIfVptVccDstRowStatusEntry ::= SEQUENCE { mscAtmIfVptVccDstRowStatus RowStatus, mscAtmIfVptVccDstComponentName DisplayString, mscAtmIfVptVccDstStorageType StorageType, mscAtmIfVptVccDstIndex NonReplicated } mscAtmIfVptVccDstRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-only STATUS mandatory DESCRIPTION "This variable is used as the basis for SNMP naming of mscAtmIfVptVccDst components. These components cannot be added nor deleted." ::= { mscAtmIfVptVccDstRowStatusEntry 1 } mscAtmIfVptVccDstComponentName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This variable provides the component's string name for use with the ASCII Console Interface" ::= { mscAtmIfVptVccDstRowStatusEntry 2 } mscAtmIfVptVccDstStorageType OBJECT-TYPE SYNTAX StorageType ACCESS read-only STATUS mandatory DESCRIPTION "This variable represents the storage type value for the mscAtmIfVptVccDst tables." ::= { mscAtmIfVptVccDstRowStatusEntry 4 } mscAtmIfVptVccDstIndex OBJECT-TYPE SYNTAX NonReplicated ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable represents the index for the mscAtmIfVptVccDst tables." ::= { mscAtmIfVptVccDstRowStatusEntry 10 } mscAtmIfVptVccDstOperTable OBJECT-TYPE SYNTAX SEQUENCE OF MscAtmIfVptVccDstOperEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This attribute group contains the operational attributes for the DestinationPvc component." ::= { mscAtmIfVptVccDst 10 } mscAtmIfVptVccDstOperEntry OBJECT-TYPE SYNTAX MscAtmIfVptVccDstOperEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscAtmIfVptVccDstOperTable." INDEX { mscAtmIfIndex, mscAtmIfVptIndex, mscAtmIfVptVccIndex, mscAtmIfVptVccDstIndex } ::= { mscAtmIfVptVccDstOperTable 1 } MscAtmIfVptVccDstOperEntry ::= SEQUENCE { mscAtmIfVptVccDstCalledAddress HexString, mscAtmIfVptVccDstCallingAddress AsciiString, mscAtmIfVptVccDstCallingVpiVci AsciiString } mscAtmIfVptVccDstCalledAddress OBJECT-TYPE SYNTAX HexString (SIZE (20)) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute represents the called address of the soft PVC." ::= { mscAtmIfVptVccDstOperEntry 3 } mscAtmIfVptVccDstCallingAddress OBJECT-TYPE SYNTAX AsciiString (SIZE (7..40)) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute represents the remote address of the soft PVC. If the address in not known, then the value of this address is Unknown." ::= { mscAtmIfVptVccDstOperEntry 4 } mscAtmIfVptVccDstCallingVpiVci OBJECT-TYPE SYNTAX AsciiString (SIZE (7..9)) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute represents the remote VPI and VCI of the soft PVC. If the VPI and VCI values are not known, this attribute is set to Unknown." ::= { mscAtmIfVptVccDstOperEntry 5 } -- -- Version and Compliance statements -- -- Object-Group Statement: -- A list of all current accessible leaf objects. -- OBJECTS { mscARtgComponentName, -- mscARtgPnniCfgNodeNbrRccListValue, -- mscARtgPnniTopPtsesInDatabase, -- mscAtmIfVccSrcCalledVpiVci, -- mscAtmIfVpcSrcRowStatus, -- mscAtmIfVptVccRpRowStatus, -- mscARtgPnniRfFwdQosClass, -- mscARtgPnniTopComponentName, -- mscARtgPnniCfgNodeNbrComponentName, -- mscAtmIfVptVccSrcState, -- mscAtmIfVccEpRowStatus, -- mscARtgPnniCfgNodeSAddrRowStatus, -- mscARtgFailedRoutingAttempts, -- mscARtgPnniRfStorageType, -- mscARtgPnniComponentName, -- mscARtgDnaDestInfoStdComponentName, -- mscARtgPnniTopNodeLinkStorageType, -- mscARtgPnniCfgNodeNbrBadPtseRx, -- mscARtgPnniCfgNodeStorageType, -- mscAtmIfVpcSrcState, -- mscARtgPnniRfFqpValue, -- mscAtmIfVccSrcLastFailureCauseCode, -- mscARtgPnniTopNodeLinkRemoteNodeId, -- mscARtgPnniCfgNodeNbrRowStatus, -- mscARtgPnniCfgNodeNbrBadPtspRx, -- mscAtmIfVpcRpRowStatus, -- mscAtmIfVpcSrcLastFailureCauseCode, -- mscARtgPnniFailedRoutingAttempts, -- mscARtgPnniCfgNodeDefSAddrScope, -- mscARtgPnniHelloHoldDown, -- mscARtgPnniDomain, -- mscARtgPnniCfgNodeNbrPtseTx, -- mscAtmIfVccRpNextHopsValue, -- mscAtmIfVptVccEpStorageType, -- mscAtmIfVptVccSrcStorageType, -- mscARtgPnniRfDestinationAddress, -- mscAtmIfVptVccDstComponentName, -- mscARtgPnniPortComponentName, -- mscARtgDnaDestInfoScope, -- mscAtmCRDnaStorageType, -- mscARtgPnniTopNodeLinkRowStatus, -- mscARtgPnniTopNodeAddrComponentName, -- mscARtgPnniTopNodeComponentName, -- mscARtgPnniCfgNodeRowStatus, -- mscARtgPnniRfTransferCapabilityBbc, -- mscARtgPnniPortStorageType, -- mscAtmIfVptVccSrcComponentName, -- mscARtgPnniCfgNodeNbrBadDbSummariesRx, -- mscARtgPnniTopActiveParentNodeId, -- mscAtmIfVpcDstCallingAddress, -- mscAtmIfVccRpComponentName, -- mscARtgPnniNodeAddressPrefix, -- mscAtmIfVpcSrcCallingAddress, -- mscARtgPnniRfTxTdpValue, -- mscAtmIfVpcSrcCalledVpi, -- mscARtgPnniPeerDelayedAckInterval, -- mscARtgPnniCfgNodeNodeAddress, -- mscARtgPnniCfgNodeNodeId, -- mscAtmIfVccDstCallingVpiVci, -- mscAtmIfVccDstStorageType, -- mscAtmIfVpcDstComponentName, -- mscARtgPnniCfgNodeNbrPtseRx, -- mscAtmIfVccDstCalledAddress, -- mscARtgRoutingAttempts, -- mscARtgPnniPtseHoldDown, -- mscARtgPnniCfgNodeNbrStorageType, -- mscARtgPnniRfBwdQosClass, -- mscAtmCRDnaRowStatus, -- mscARtgPnniCfgNodeNbrPtseReqTx, -- mscAtmIfVpcDstCalledAddress, -- mscARtgDnaComponentName, -- mscARtgPnniStorageType, -- mscARtgPnniCfgNodePeerGroupId, -- mscARtgPnniPortRowStatus, -- mscAtmIfVptVccDstCalledAddress, -- mscAtmIfVptVccSrcRetryCount, -- mscAtmIfVptVccSrcCallingAddress, -- mscARtgPnniRfClippingBbc, -- mscARtgPnniSuccessfulRoutingAttempts, -- mscARtgPnniDefaultScope, -- mscAtmIfVptVccDstRowStatus, -- mscARtgPnniRfBqpValue, -- mscAtmIfVptVccRpStorageType, -- mscARtgRowStatus, -- mscARtgPnniRfBestEffort, -- mscARtgPnniRfRxTdpValue, -- mscAtmIfVptVccSrcLastFailureDiagCode, -- mscAtmIfVpcRpNextHopsValue, -- mscARtgPnniOverrideDelay, -- mscARtgPnniCfgNodeDefSAddrState, -- mscARtgPnniMaxAlternateRoutesOnCrankback, -- mscARtgPnniCfgNodeOpNodeId, -- mscARtgPnniTopRowStatus, -- mscAtmIfVpcSrcCalledAddress, -- mscARtgPnniRowStatus, -- mscARtgPnniCfgNodeNbrPtseReqRx, -- mscARtgPnniTopNodeAddrStorageType, -- mscARtgPnniTopNodeStorageType, -- mscAtmIfVptVccEpRowStatus, -- mscARtgPnniAlternateRoutingAttempts, -- mscARtgPnniPortStdComponentName, -- mscARtgPnniRfAtmServiceCategory, -- mscARtgDnaDestInfoComponentName, -- mscAtmIfVpcSrcComponentName, -- mscAtmIfVpcRpStorageType, -- mscAtmIfVccDstComponentName, -- mscARtgPnniCfgNodeSAddrScope, -- mscARtgPnniCfgNodeNumRccs, -- mscARtgPnniCfgNodeOpPeerGroupId, -- mscARtgPnniCfgNodeNbrDbSummariesTx, -- mscAtmIfVptVccRpNextHopsValue, -- mscARtgPnniCfgNodeDefSAddrStorageType, -- mscAtmIfVccRpRowStatus, -- mscARtgPnniCfgNodeNbrBadPtseAckRx, -- mscARtgPnniCfgNodeDefSAddrAddress, -- mscARtgPnniRfOptimizationMetric, -- mscAtmCRComponentName, -- mscARtgPnniAvcrMt, -- mscARtgPnniCfgNodeCurrentLeadershipPriority, -- mscARtgPnniPglInitTime, -- mscAtmIfVptVccDstStorageType, -- mscARtgPnniTopNodeAddrRowStatus, -- mscARtgDnaStorageType, -- mscARtgPnniCfgNodeDefSAddrComponentName, -- mscAtmIfVptVccSrcLastFailureCauseCode, -- mscARtgPnniRfTxTrafficDescType, -- mscARtgPnniTopPglNodeId, -- mscAtmCRStorageType, -- mscAtmIfVccSrcState, -- mscARtgPnniCfgNodeSAddrComponentName, -- mscAtmIfVpcSrcLastFailureDiagCode, -- mscAtmIfVptVccDstCallingVpiVci, -- mscAtmIfVccSrcComponentName, -- mscAtmIfVccEpApplicationName, -- mscAtmIfVptVccRpComponentName, -- mscAtmIfVccSrcCalledAddress, -- mscARtgPnniRfMaxRoutes, -- mscARtgStorageType, -- mscAtmIfVccDstRowStatus, -- mscARtgPnniRfRowStatus, -- mscARtgPnniCfgNodeSAddrSuppress, -- mscARtgPnniRequestRxmtInterval, -- mscARtgPnniCfgNodeNbrDbSummariesRx, -- mscARtgPnniCfgNodeNbrPtseAcksTx, -- mscAtmIfVccEpComponentName, -- mscARtgPnniCfgNodeNbrBadPtseReqRx, -- mscARtgPnniHelloInactivityFactor, -- mscARtgPnniHelloInterval, -- mscARtgPnniTopNodeRowStatus, -- mscARtgPnniCfgNodeNbrPtspTx, -- mscARtgPnniPtseRefreshInterval, -- mscARtgPnniRestrictTransit, -- mscARtgDnaRowStatus, -- mscAtmIfVccSrcStorageType, -- mscARtgPnniAvcrPm, -- mscAtmIfVptVccEpComponentName, -- mscARtgPnniRfRxTrafficDescType, -- mscARtgPnniCfgNodeNumNeighbors, -- mscARtgPnniRfComponentName, -- mscARtgDnaDestInfoStorageType, -- mscAtmIfVpcSrcStorageType, -- mscARtgPnniTopNodeLinkComponentName, -- mscARtgPnniCfgNodeSAddrState, -- mscARtgPnniCfgNodeComponentName, -- mscAtmIfVccSrcCallingAddress, -- mscAtmIfVpcDstRowStatus, -- mscARtgPnniTopNodeLinkRemotePortId, -- mscARtgPnniTopologyMemoryExhaustion, -- mscARtgDnaDestInfoType, -- mscARtgPnniTopPreferredPglNodeId, -- mscAtmIfVpcDstCallingVpi, -- mscARtgPnniCfgNodeNbrPtseAcksRx, -- mscARtgPnniRfBearerClassBbc, -- mscARtgDnaDestInfoReachability, -- mscAtmIfVpcDstStorageType, -- mscARtgPnniTopStorageType, -- mscAtmIfVptVccSrcRowStatus, -- mscARtgPnniCfgNodeNbrPtspRx, -- mscARtgPnniTopNodeAddrScope, -- mscAtmIfVptVccEpApplicationName, -- mscAtmIfVptVccSrcCalledVpiVci, -- mscAtmIfVccSrcLastFailureDiagCode, -- mscAtmIfVccSrcRetryCount, -- mscARtgDnaDestInfoRowStatus, -- mscARtgPnniCfgNodeSAddrStorageType, -- mscAtmIfVccSrcRowStatus, -- mscARtgPnniCfgNodeNbrPeerState, -- mscAtmIfVpcRpComponentName, -- mscARtgPnniReElectionInterval, -- mscARtgPnniOptMetricValue, -- mscARtgPnniPtseLifetimeFactor, -- mscAtmIfVpcSrcRetryCount, -- mscAtmIfVccRpStorageType, -- mscARtgPnniCfgNodeDefSAddrRowStatus, -- mscARtgPnniCfgNodePglElectionState, -- mscAtmIfVptVccDstCallingAddress, -- mscAtmIfVptVccSrcCalledAddress, -- mscAtmIfVccEpStorageType, -- mscAtmCRDnaComponentName, -- mscAtmCRRowStatus, -- mscAtmIfVccDstCallingAddress } -- STATUS mandatory -- DESCRIPTION -- "A list of all current accessible leaf objects." atmNetworkingGroup OBJECT IDENTIFIER ::= { atmNetworkingMIB 1 } atmNetworkingGroupCA OBJECT IDENTIFIER ::= { atmNetworkingGroup 1 } atmNetworkingGroupCA02 OBJECT IDENTIFIER ::= { atmNetworkingGroupCA 3 } atmNetworkingGroupCA02A OBJECT IDENTIFIER ::= { atmNetworkingGroupCA02 2 } -- Agent-Capabilities Statement: -- PRODUCT-RELEASE "MscPassport Release 1.2 AtmNetworking." -- STATUS mandatory -- DESCRIPTION "Carrier Passport AtmNetworking MIB: MIB Version CA02A, -- Software Version CA02S9C." -- SUPPORTS Nortel-MsCarrier-MscPassport-AtmNetworkingMIB -- INCLUDES { atmNetworkingGroupCA02A } atmNetworkingCapabilities OBJECT IDENTIFIER ::= { atmNetworkingMIB 3 } atmNetworkingCapabilitiesCA OBJECT IDENTIFIER ::= { atmNetworkingCapabilities 1 } atmNetworkingCapabilitiesCA02 OBJECT IDENTIFIER ::= { atmNetworkingCapabilitiesCA 3 } atmNetworkingCapabilitiesCA02A OBJECT IDENTIFIER ::= { atmNetworkingCapabilitiesCA02 2 } END