------------------------------------------------------------------------------- -- file: E3Extensions.mib -- -- description: -- This file contains the SNMP definitions for Newbridge Extensions on -- E3 objects. -- -- history: -- P.129221 / 96.11.27 / R. To / Creation from V1.0 of MIBTemplate.mib -- %%history-start%% -- 96.12.13 rickt P.129221: Added new E3Extensions MIB Module. -- %%history-end%% -- -- Copyright 1996 Newbridge Networks Corporation. All Rights Reserved ------------------------------------------------------------------------------- NNCEXTE3-MIB DEFINITIONS ::= BEGIN IMPORTS nncExtensions FROM NNCGNI0001-SMI MODULE-IDENTITY, OBJECT-TYPE, Gauge32, Integer32 FROM SNMPv2-SMI MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF ifIndex FROM IF-MIB; nncExtE3 MODULE-IDENTITY LAST-UPDATED "9611251500Z" ORGANIZATION "Newbridge Networks Corporation" CONTACT-INFO "Newbridge Networks Corporation Postal: 600 March Road Kanata, Ontario Canada K2K 2E6 Phone: +1 613 591 3600 Fax: +1 613 591 3680" DESCRIPTION "This module contains definitions for Newbridge extensions to E3 objects. It is used as a supplement to rfc1407." ::= { nncExtensions 40 } nncExtE3Objects OBJECT IDENTIFIER ::= { nncExtE3 1 } nncExtE3Traps OBJECT IDENTIFIER ::= { nncExtE3 2 } nncExtE3Groups OBJECT IDENTIFIER ::= { nncExtE3 3 } nncExtE3Compliances OBJECT IDENTIFIER ::= { nncExtE3 4 } -------------------------------------------------------------------------------- -- Object Definitions -- -- This MIB module contains the following tables: -- -- E3 Near End Current 15 Minutes Table -- E3 Near End Interval 15 Minutes Table -- E3 Near End Total Table -- -- E3 Far End Current 15 Minutes Table -- E3 Far End Interval 15 Minutes Table -- E3 Far End Total Table -- -------------------------------------------------------------------------------- -------------------------------------------------------------------------------- -- Table 1: Near End Statistics Current 15 Minutes Table -------------------------------------------------------------------------------- nncExtE3Current15MinTable OBJECT-TYPE SYNTAX SEQUENCE OF NncExtE3Current15MinEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NNC Extension to dsx3CurrentTable." ::= { nncExtE3Objects 1 } nncExtE3Current15MinEntry OBJECT-TYPE SYNTAX NncExtE3Current15MinEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in nncExtE3Current15MinTable." INDEX { ifIndex } ::= { nncExtE3Current15MinTable 1 } NncExtE3Current15MinEntry ::= SEQUENCE { nncExtE3Current15MinESs Gauge32, nncExtE3Current15MinSESs Gauge32, nncExtE3Current15MinSEFs Gauge32 } nncExtE3Current15MinESs OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Path Errored Seconds encountered by a E3 interface in the current 15 minute interval. This counts the seconds containing one or more BIP errors, one or more LOF defects, one or more LOS defects, or a detected incoming AIS. This counter is valid when an interface is configured for Direct cell mapping. When an interface is configured for PLCP cell mapping, the counter returns the last valid count when the port is in the Direct mode." ::= { nncExtE3Current15MinEntry 1 } nncExtE3Current15MinSESs OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Path Severely Errored Seconds encountered by a E3 interface in the current 15 minute interval. This counts the seconds containing 34 or more BIP errors, one or more LOF defects, one or more LOS defects, or a detected incoming AIS. This counter is valid when an interface is configured for Direct cell mapping. When an interface is configured for PLCP cell mapping, the counter returns the last valid count when the port is in the Direct mode." ::= { nncExtE3Current15MinEntry 2 } nncExtE3Current15MinSEFs OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Path Severely Errored Frames encountered by a E3 interface in the current 15 minute interval. This counts framing pattern errors. In Direct cell mapping mode, this is the count of frames with errored FA1/FA2 bytes in the G.832 overhead. In PLCP mode, this is the count of frames with an errored G.751 Frame Alignment byte." ::= { nncExtE3Current15MinEntry 3 } -------------------------------------------------------------------------------- -- Table 2: Near End Statistics Interval 15 Minutes Table -------------------------------------------------------------------------------- nncExtE3Interval15MinTable OBJECT-TYPE SYNTAX SEQUENCE OF NncExtE3Interval15MinEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NNC Extension to dsx3IntervalTable." ::= { nncExtE3Objects 2 } nncExtE3Interval15MinEntry OBJECT-TYPE SYNTAX NncExtE3Interval15MinEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in nncExtE3Interval15MinTable." INDEX { ifIndex, nncExtE3Interval15MinNumber } ::= { nncExtE3Interval15MinTable 1 } NncExtE3Interval15MinEntry ::= SEQUENCE { nncExtE3Interval15MinNumber Integer32, nncExtE3Interval15MinESs Gauge32, nncExtE3Interval15MinSESs Gauge32, nncExtE3Interval15MinSEFs Gauge32 } nncExtE3Interval15MinNumber OBJECT-TYPE SYNTAX Integer32 (1..96) MAX-ACCESS not-accessible STATUS current DESCRIPTION "A number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes interval (assuming that all 96 intervals are valid)." ::= { nncExtE3Interval15MinEntry 1 } nncExtE3Interval15MinESs OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Path Errored Seconds encountered by a E3 interface in one of the previous 15 minute intervals. This counts the seconds containing one or more BIP errors, one or more LOF defects, one or more LOS defects, or a detected incoming AIS. This counter is valid when an interface is configured for Direct cell mapping. When an interface is configured for PLCP cell mapping, the counter returns the last valid count when the port is in the Direct mode." ::= { nncExtE3Interval15MinEntry 2 } nncExtE3Interval15MinSESs OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Path Severely Errored Seconds encountered by a E3 interface in one of the previous 15 minute intervals. This counts the seconds containing 34 or more BIP errors, one or more LOF defects, one or more LOS defects, or a detected incoming AIS. This counter is valid when an interface is configured for Direct cell mapping. When an interface is configured for PLCP cell mapping, the counter returns the last valid count when the port is in the Direct mode." ::= { nncExtE3Interval15MinEntry 3 } nncExtE3Interval15MinSEFs OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Path Severely Errored Frames encountered by a E3 interface in one of the previous 15 minute intervals. This counts framing pattern errors. In Direct cell mapping mode, this is the count of frames with errored FA1/FA2 bytes in the G.832 overhead. In PLCP mode, this is the count of frames with an errored G.751 Frame Alignment byte." ::= { nncExtE3Interval15MinEntry 4 } -------------------------------------------------------------------------------- -- Table 3: Near End Statistics Total 24 Hours Table -------------------------------------------------------------------------------- nncExtE3Total24HrTable OBJECT-TYPE SYNTAX SEQUENCE OF NncExtE3Total24HrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NNC Extension to dsx3TotalTable." ::= { nncExtE3Objects 3 } nncExtE3Total24HrEntry OBJECT-TYPE SYNTAX NncExtE3Total24HrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in nncExtE3Total24HrTable." INDEX { ifIndex } ::= { nncExtE3Total24HrTable 1 } NncExtE3Total24HrEntry ::= SEQUENCE { nncExtE3Total24HrESs Gauge32, nncExtE3Total24HrSESs Gauge32, nncExtE3Total24HrSEFs Gauge32 } nncExtE3Total24HrESs OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Path Errored Seconds encountered by a E3 interface in the previous 24 hours interval. This counts the seconds containing one or more BIP errors, one or more LOF defects, one or more LOS defects, or a detected incoming AIS. This counter is valid when an interface is configured for Direct cell mapping. When an interface is configured for PLCP cell mapping, the counter returns the last valid count when the port is in the Direct mode." ::= { nncExtE3Total24HrEntry 1 } nncExtE3Total24HrSESs OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Path Severely Errored Seconds encountered by a E3 interface in the previous 24 hours interval. This counts the seconds containing 34 or more BIP errors, one or more LOF defects, one or more LOS defects, or a detected incoming AIS. This counter is valid when an interface is configured for Direct cell mapping. When an interface is configured for PLCP cell mapping, the counter returns the last valid count when the port is in the Direct mode." ::= { nncExtE3Total24HrEntry 2 } nncExtE3Total24HrSEFs OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Path Severely Errored Frames encountered by a E3 interface in the previous 24 hours interval. This counts framing pattern errors. In Direct cell mapping mode, this is the count of frames with errored FA1/FA2 bytes in the G.832 overhead. In PLCP mode, this is the count of frames with an errored G.751 Frame Alignment byte." ::= { nncExtE3Total24HrEntry 3 } -------------------------------------------------------------------------------- -- Table 4: Far End Statistics Current 15 Minutes Table -------------------------------------------------------------------------------- nncExtE3FarEndCurrent15MinTable OBJECT-TYPE SYNTAX SEQUENCE OF NncExtE3FarEndCurrent15MinEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NNC Extension to dsx3FarEndCurrentTable." ::= { nncExtE3Objects 4 } nncExtE3FarEndCurrent15MinEntry OBJECT-TYPE SYNTAX NncExtE3FarEndCurrent15MinEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in nncExtE3FarEndCurrent15MinTable." INDEX { ifIndex } ::= { nncExtE3FarEndCurrent15MinTable 1 } NncExtE3FarEndCurrent15MinEntry ::= SEQUENCE { nncExtE3FarEndCurrent15MinFEBEs Gauge32, nncExtE3FarEndCurrent15MinESs Gauge32, nncExtE3FarEndCurrent15MinSESs Gauge32 } nncExtE3FarEndCurrent15MinFEBEs OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Far End Block Errors encountered by a E3 interface in the current 15 minute interval. This is the count of received FEBEs. This counter will not increment while failure defects are present. This counter is valid when an interface is configured for Direct cell mapping. When an interface is configured for PLCP cell mapping, the counter returns the last valid count when the port is in the Direct mode." ::= { nncExtE3FarEndCurrent15MinEntry 1 } nncExtE3FarEndCurrent15MinESs OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Far End Path Errored Seconds encountered by a E3 interface in the current 15 minute interval. This counts the seconds containing one or more FEBEs. This counter is valid when an interface is configured for Direct cell mapping. When an interface is configured for PLCP cell mapping, the counter returns the last valid count when the port is in the Direct mode." ::= { nncExtE3FarEndCurrent15MinEntry 2 } nncExtE3FarEndCurrent15MinSESs OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Far End Path Severely Errored Seconds encountered by a E3 interface in the current 15 minute interval. This counts the seconds containing 34 or more FEBEs. This counter is valid when an interface is configured for Direct cell mapping. When an interface is configured for PLCP cell mapping, the counter returns the last valid count when the port is in the Direct mode." ::= { nncExtE3FarEndCurrent15MinEntry 3 } -------------------------------------------------------------------------------- -- Table 5: Far End Statistics Interval 15 Minutes Table -------------------------------------------------------------------------------- nncExtE3FarEndInterval15MinTable OBJECT-TYPE SYNTAX SEQUENCE OF NncExtE3FarEndInterval15MinEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NNC Extension to dsx3FarEndIntervalTable." ::= { nncExtE3Objects 5 } nncExtE3FarEndInterval15MinEntry OBJECT-TYPE SYNTAX NncExtE3FarEndInterval15MinEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in nncExtE3FarEndInterval15MinTable." INDEX { ifIndex, nncExtE3FarEndInterval15MinNumber } ::= { nncExtE3FarEndInterval15MinTable 1 } NncExtE3FarEndInterval15MinEntry ::= SEQUENCE { nncExtE3FarEndInterval15MinNumber Integer32, nncExtE3FarEndInterval15MinFEBEs Gauge32, nncExtE3FarEndInterval15MinESs Gauge32, nncExtE3FarEndInterval15MinSESs Gauge32 } nncExtE3FarEndInterval15MinNumber OBJECT-TYPE SYNTAX Integer32 (1..96) MAX-ACCESS not-accessible STATUS current DESCRIPTION "A number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes interval (assuming that all 96 intervals are valid)." ::= { nncExtE3FarEndInterval15MinEntry 1 } nncExtE3FarEndInterval15MinFEBEs OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Far End Block Errors encountered by a E3 interface in one of the previous 15 minute intervals. This is the count of received FEBEs. This counter will not increment while failure defects are present. This counter is valid when an interface is configured for Direct cell mapping. When an interface is configured for PLCP cell mapping, the counter returns the last valid count when the port is in the Direct mode." ::= { nncExtE3FarEndInterval15MinEntry 2 } nncExtE3FarEndInterval15MinESs OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Far End Path Errored Seconds encountered by a E3 interface in one of the previous 15 minute intervals. This counts the seconds containing one or more FEBEs. This counter is valid when an interface is configured for Direct cell mapping. When an interface is configured for PLCP cell mapping, the counter returns the last valid count when the port is in the Direct mode." ::= { nncExtE3FarEndInterval15MinEntry 3 } nncExtE3FarEndInterval15MinSESs OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Far End Path Severely Errored Seconds encountered by a E3 interface in one of the previous 15 minute intervals. This counts the seconds containing 34 or more FEBEs. This counter is valid when an interface is configured for Direct cell mapping. When an interface is configured for PLCP cell mapping, the counter returns the last valid count when the port is in the Direct mode." ::= { nncExtE3FarEndInterval15MinEntry 4 } -------------------------------------------------------------------------------- -- Table 6: Far End Statistics Total 24 Hours Table -------------------------------------------------------------------------------- nncExtE3FarEndTotal24HrTable OBJECT-TYPE SYNTAX SEQUENCE OF NncExtE3FarEndTotal24HrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NNC Extension to dsx3FarEndTotalTable." ::= { nncExtE3Objects 6 } nncExtE3FarEndTotal24HrEntry OBJECT-TYPE SYNTAX NncExtE3FarEndTotal24HrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in nncExtE3FarEndTotal24HrTable." INDEX { ifIndex } ::= { nncExtE3FarEndTotal24HrTable 1 } NncExtE3FarEndTotal24HrEntry ::= SEQUENCE { nncExtE3FarEndTotal24HrFEBEs Gauge32, nncExtE3FarEndTotal24HrESs Gauge32, nncExtE3FarEndTotal24HrSESs Gauge32 } nncExtE3FarEndTotal24HrFEBEs OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Far End Block Errors encountered by a E3 interface in the previous 24 hours interval. This is the count of received FEBEs. This counter will not increment while failure defects are present. This counter is valid when an interface is configured for Direct cell mapping. When an interface is configured for PLCP cell mapping, the counter returns the last valid count when the port is in the Direct mode." ::= { nncExtE3FarEndTotal24HrEntry 1 } nncExtE3FarEndTotal24HrESs OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Far End Path Errored Seconds encountered by a E3 interface in the previous 24 hours interval. This counts the seconds containing one or more FEBEs. This counter is valid when an interface is configured for Direct cell mapping. When an interface is configured for PLCP cell mapping, the counter returns the last valid count when the port is in the Direct mode." ::= { nncExtE3FarEndTotal24HrEntry 2 } nncExtE3FarEndTotal24HrSESs OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Far End Path Severely Errored Seconds encountered by a E3 interface in the previous 24 hours interval. This counts the seconds containing 34 or more FEBEs. This counter is valid when an interface is configured for Direct cell mapping. When an interface is configured for PLCP cell mapping, the counter returns the last valid count when the port is in the Direct mode." ::= { nncExtE3FarEndTotal24HrEntry 3 } -------------------------------------------------------------------------------- -- Conformance Group Definitions -------------------------------------------------------------------------------- nncExtE3Current15MinGroup OBJECT-GROUP OBJECTS { nncExtE3Current15MinESs, nncExtE3Current15MinSESs, nncExtE3Current15MinSEFs } STATUS current DESCRIPTION "Collection of objects providing 15 minute current statistics for E3 interface." ::= { nncExtE3Groups 1 } nncExtE3Interval15MinGroup OBJECT-GROUP OBJECTS { nncExtE3Interval15MinNumber, nncExtE3Interval15MinESs, nncExtE3Interval15MinSESs, nncExtE3Interval15MinSEFs } STATUS current DESCRIPTION "Collection of objects providing 15 minute interval statistics for E3 interface." ::= { nncExtE3Groups 2 } nncExtE3Total24HrGroup OBJECT-GROUP OBJECTS { nncExtE3Total24HrESs, nncExtE3Total24HrSESs, nncExtE3Total24HrSEFs } STATUS current DESCRIPTION "Collection of objects providing previous 24 hours statistics for E3 interface." ::= { nncExtE3Groups 3 } nncExtE3FarEndCurrent15MinGroup OBJECT-GROUP OBJECTS { nncExtE3FarEndCurrent15MinFEBEs, nncExtE3FarEndCurrent15MinESs, nncExtE3FarEndCurrent15MinSESs } STATUS current DESCRIPTION "Collection of objects providing 15 minute current statistics for E3 interface." ::= { nncExtE3Groups 4 } nncExtE3FarEndInterval15MinGroup OBJECT-GROUP OBJECTS { nncExtE3FarEndInterval15MinNumber, nncExtE3FarEndInterval15MinFEBEs, nncExtE3FarEndInterval15MinESs, nncExtE3FarEndInterval15MinSESs } STATUS current DESCRIPTION "Collection of objects providing 15 minute interval statistics for E3 interface." ::= { nncExtE3Groups 5 } nncExtE3FarEndTotal24HrGroup OBJECT-GROUP OBJECTS { nncExtE3FarEndTotal24HrFEBEs, nncExtE3FarEndTotal24HrESs, nncExtE3FarEndTotal24HrSESs } STATUS current DESCRIPTION "Collection of objects providing previous 24 hours statistics for E3 interface." ::= { nncExtE3Groups 6 } -------------------------------------------------------------------------------- -- Compliance Statements (mandatory) -------------------------------------------------------------------------------- nncExtE3Compliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for Newbridge E3 interfaces." MODULE MANDATORY-GROUPS { nncExtE3Current15MinGroup, nncExtE3Interval15MinGroup, nncExtE3Total24HrGroup, nncExtE3FarEndCurrent15MinGroup, nncExtE3FarEndInterval15MinGroup, nncExtE3FarEndTotal24HrGroup } ::= { nncExtE3Compliances 1 } ------------------------------------------------------------------------------- -- Review Minutes ------------------------------------------------------------------------------- -- MINUTES-BEGIN -- REVIEW-DATE "1996.11.27" -- BODY " -- -- TO: Ken Duesling*, Aleksandar Radovic*, Nelson Gillette* -- CC: Randy Jone, Steve Bews, Steve McCaughan -- Numbers Admin, Melanie Paquette -- FROM: Rick To* -- -- A meeting was held on 1996.11.27 to review NncExtDsx3.mib -- Attendees are marked with * in the TO and CC lists above. -- -- Outcome -- -- It was the consensus of the review team that this file is -- acceptable with the indicated modifications. -- -- Actions: -- A1 - Rick To to update the file as indicated in D1 below. -- Response: Status: CLOSED -- -- Decisions: -- D1 - NncExtDsx3.mib shall be updated as follows: -- a. Restrict context of these objects to only E3; rename MIB -- module from NncExtDsx3 to NncExtE3. -- b. Expand definitions of the stats objects. Use information -- from 31FS0096. -- c. For Near End ESs and SESs, indicate that they are only -- available in Direct Mode (and not PLCP). -- d. Add 15Min to the name of Current and Interval objects. -- " -- -- END-MINUTES -- END -- DEFINITION OF NNCEXTE3-MIB