-- varfix Thu Dec 22 10:57:54 EST 1994 user: craig -- File created using agent2concat -- By: craig -- Date: Thu Dec 22 10:57:39 EST 1994 LANART-AGENT DEFINITIONS ::= BEGIN -- -- FILE: /bigguy/users/craig/mibs/src/rfc/rfc1155.smi -- -- Changes to rfc1155 (SMI): -- Removed EXPORTS. -- Added explicit definitions of ccitt, null, iso, org, and dod. -- Commented out OBJECT-TYPE macro definition (since will use -- the definition from RFC-1212). -- Commented out definitions of syntax types and replaced -- with SMIC directives to enable them. -- no IMPORTS IMPORTS IpAddress, NetworkAddress, Counter, Gauge, TimeTicks, OBJECT-TYPE FROM RFC1155-SMI TRAP-TYPE FROM RFC-1215; -- Define OIDs ccitt OBJECT IDENTIFIER ::= { 0 } null OBJECT IDENTIFIER ::= { ccitt 0 } iso OBJECT IDENTIFIER ::= { 1 } org OBJECT IDENTIFIER ::= { iso 3 } dod OBJECT IDENTIFIER ::= { org 6 } internet OBJECT IDENTIFIER ::= { dod 1 } directory OBJECT IDENTIFIER ::= { internet 1 } mgmt OBJECT IDENTIFIER ::= { internet 2 } experimental OBJECT IDENTIFIER ::= { internet 3 } private OBJECT IDENTIFIER ::= { internet 4 } enterprises OBJECT IDENTIFIER ::= { private 1 } -- Make builtin items known -- SMI NetworkAddress -- SMI IpAddress -- SMI Counter -- SMI Gauge -- SMI TimeTicks -- SMI Opaque -- definition of object types -- OBJECT-TYPE MACRO ::= -- BEGIN -- TYPE NOTATION ::= "SYNTAX" type (TYPE ObjectSyntax) -- "ACCESS" Access -- "STATUS" Status -- VALUE NOTATION ::= value (VALUE ObjectName) -- -- Access ::= "read-only" -- | "read-write" -- | "write-only" -- | "not-accessible" -- Status ::= "mandatory" -- | "optional" -- | "obsolete" -- END -- -- names of objects in the MIB -- -- ObjectName ::= OBJECT IDENTIFIER -- -- syntax of objects in the MIB -- -- ObjectSyntax ::= -- CHOICE { -- simple -- SimpleSyntax, -- note that simple SEQUENCEs are not directly -- mentioned here to keep things simple (i.e., -- prevent mis-use). However, application-wide -- types which are IMPLICITly encoded simple -- SEQUENCEs may appear in the following CHOICE -- -- application-wide -- ApplicationSyntax -- } -- -- SimpleSyntax ::= -- CHOICE { -- number INTEGER, -- string OCTET STRING, -- object OBJECT IDENTIFIER, -- empty NULL -- } -- -- ApplicationSyntax ::= -- CHOICE { -- address NetworkAddress, -- counter Counter, -- gauge Gauge, -- ticks TimeTicks, -- arbitrary Opaque -- other application-wide types, as they are -- defined, will be added here -- } -- -- -- application-wide types -- NetworkAddress ::= -- CHOICE { -- internet IpAddress -- } -- -- IpAddress ::= -- [APPLICATION 0] -- IMPLICIT OCTET STRING (SIZE (4)) -- -- Counter ::= -- [APPLICATION 1] -- IMPLICIT INTEGER (0..4294967295) -- -- Gauge ::= -- [APPLICATION 2] -- IMPLICIT INTEGER (0..4294967295) -- -- TimeTicks ::= -- [APPLICATION 3] -- IMPLICIT INTEGER (0..4294967295) -- -- Opaque ::= -- [APPLICATION 4] -- IMPLICIT OCTET STRING -- -- FILE: /bigguy/users/craig/mibs/src/rfc/RFC-1212.smi -- -- changes to RFC-1212 (Concise MIB OBJECT-TYPE definition): -- Removed IMPORTS. -- Commented out OBJECT-TYPE macro definition and replaced -- with SMIC directive to enable it. -- Make builtin items known -- SMI OBJECT-TYPE -- OBJECT-TYPE MACRO ::= -- BEGIN -- TYPE NOTATION ::= -- must conform to -- RFC1155's ObjectSyntax -- "SYNTAX" type(ObjectSyntax) -- "ACCESS" Access -- "STATUS" Status -- DescrPart -- ReferPart -- IndexPart -- DefValPart -- VALUE NOTATION ::= value (VALUE ObjectName) -- -- Access ::= "read-only" -- | "read-write" -- | "write-only" -- | "not-accessible" -- Status ::= "mandatory" -- | "optional" -- | "obsolete" -- | "deprecated" -- -- DescrPart ::= -- "DESCRIPTION" value (description DisplayString) -- | empty -- -- ReferPart ::= -- "REFERENCE" value (reference DisplayString) -- | empty -- -- IndexPart ::= -- "INDEX" "{" IndexTypes "}" -- | empty -- IndexTypes ::= -- IndexType | IndexTypes "," IndexType -- IndexType ::= -- if indexobject, use the SYNTAX -- value of the correspondent -- OBJECT-TYPE invocation -- value (indexobject ObjectName) -- otherwise use named SMI type -- must conform to IndexSyntax below -- | type (indextype) -- -- DefValPart ::= -- "DEFVAL" "{" value (defvalue ObjectSyntax) "}" -- | empty -- END -- -- IndexSyntax ::= -- CHOICE { -- number -- INTEGER (0..MAX), -- string -- OCTET STRING, -- object -- OBJECT IDENTIFIER, -- address -- NetworkAddress, -- ipAddress -- IpAddress -- } -- -- FILE: /bigguy/users/craig/mibs/src/rfc/rfc1213.mib -- -- Changes to rfc1213 (MIB-II): -- No changes needed. -- This MIB module uses the extended OBJECT-TYPE macro as -- defined in [14]; -- MIB-II (same prefix as MIB-I) mib-2 OBJECT IDENTIFIER ::= { mgmt 1 } -- textual conventions DisplayString ::= OCTET STRING -- This data type is used to model textual information taken -- from the NVT ASCII character set. By convention, objects -- with this syntax are declared as having -- -- SIZE (0..255) PhysAddress ::= OCTET STRING -- This data type is used to model media addresses. For many -- types of media, this will be in a binary representation. -- For example, an ethernet address would be represented as -- a string of 6 octets. -- groups in MIB-II system OBJECT IDENTIFIER ::= { mib-2 1 } interfaces OBJECT IDENTIFIER ::= { mib-2 2 } at OBJECT IDENTIFIER ::= { mib-2 3 } ip OBJECT IDENTIFIER ::= { mib-2 4 } icmp OBJECT IDENTIFIER ::= { mib-2 5 } tcp OBJECT IDENTIFIER ::= { mib-2 6 } udp OBJECT IDENTIFIER ::= { mib-2 7 } egp OBJECT IDENTIFIER ::= { mib-2 8 } -- historical (some say hysterical) -- cmot OBJECT IDENTIFIER ::= { mib-2 9 } transmission OBJECT IDENTIFIER ::= { mib-2 10 } snmp OBJECT IDENTIFIER ::= { mib-2 11 } -- the System group -- Implementation of the System group is mandatory for all -- systems. If an agent is not configured to have a value -- for any of these variables, a string of length 0 is -- returned. sysDescr OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "A textual description of the entity. This value should include the full name and version identification of the system's hardware type, software operating-system, and networking software. It is mandatory that this only contain printable ASCII characters." ::= { system 1 } sysObjectID OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The vendor's authoritative identification of the network management subsystem contained in the entity. This value is allocated within the SMI enterprises subtree (1.3.6.1.4.1) and provides an easy and unambiguous means for determining `what kind of box' is being managed. For example, if vendor `Flintstones, Inc.' was assigned the subtree 1.3.6.1.4.1.4242, it could assign the identifier 1.3.6.1.4.1.4242.1.1 to its `Fred Router'." ::= { system 2 } sysUpTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "The time (in hundredths of a second) since the network management portion of the system was last re-initialized." ::= { system 3 } sysContact OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-write STATUS mandatory DESCRIPTION "The textual identification of the contact person for this managed node, together with information on how to contact this person." ::= { system 4 } sysName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-write STATUS mandatory DESCRIPTION "An administratively-assigned name for this managed node. By convention, this is the node's fully-qualified domain name." ::= { system 5 } sysLocation OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-write STATUS mandatory DESCRIPTION "The physical location of this node (e.g., `telephone closet, 3rd floor')." ::= { system 6 } sysServices OBJECT-TYPE SYNTAX INTEGER (0..127) ACCESS read-only STATUS mandatory DESCRIPTION "A value which indicates the set of services that this entity primarily offers. The value is a sum. This sum initially takes the value zero, Then, for each layer, L, in the range 1 through 7, that this node performs transactions for, 2 raised to (L - 1) is added to the sum. For example, a node which performs primarily routing functions would have a value of 4 (2^(3-1)). In contrast, a node which is a host offering application services would have a value of 72 (2^(4-1) + 2^(7-1)). Note that in the context of the Internet suite of protocols, values should be calculated accordingly: layer functionality 1 physical (e.g., repeaters) 2 datalink/subnetwork (e.g., bridges) 3 internet (e.g., IP gateways) 4 end-to-end (e.g., IP hosts) 7 applications (e.g., mail relays) For systems including OSI protocols, layers 5 and 6 may also be counted." ::= { system 7 } -- the Interfaces group -- Implementation of the Interfaces group is mandatory for -- all systems. ifNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of network interfaces (regardless of their current state) present on this system." ::= { interfaces 1 } -- the Interfaces table -- The Interfaces table contains information on the entity's -- interfaces. Each interface is thought of as being -- attached to a `subnetwork'. Note that this term should -- not be confused with `subnet' which refers to an -- addressing partitioning scheme used in the Internet suite -- of protocols. ifTable OBJECT-TYPE SYNTAX SEQUENCE OF IfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of interface entries. The number of entries is given by the value of ifNumber." ::= { interfaces 2 } ifEntry OBJECT-TYPE SYNTAX IfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An interface entry containing objects at the subnetwork layer and below for a particular interface." INDEX { ifIndex } ::= { ifTable 1 } IfEntry ::= SEQUENCE { ifIndex INTEGER, ifDescr DisplayString, ifType INTEGER, ifMtu INTEGER, ifSpeed Gauge, ifPhysAddress PhysAddress, ifAdminStatus INTEGER, ifOperStatus INTEGER, ifLastChange TimeTicks, ifInOctets Counter, ifInUcastPkts Counter, ifInNUcastPkts Counter, ifInDiscards Counter, ifInErrors Counter, ifInUnknownProtos Counter, ifOutOctets Counter, ifOutUcastPkts Counter, ifOutNUcastPkts Counter, ifOutDiscards Counter, ifOutErrors Counter, ifOutQLen Gauge, ifSpecific OBJECT IDENTIFIER } ifIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each interface. Its value ranges between 1 and the value of ifNumber. The value for each interface must remain constant at least from one re-initialization of the entity's network management system to the next re- initialization." ::= { ifEntry 1 } ifDescr OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "A textual string containing information about the interface. This string should include the name of the manufacturer, the product name and the version of the hardware interface." ::= { ifEntry 2 } ifType OBJECT-TYPE SYNTAX INTEGER { other(1), -- none of the following regular1822(2), hdh1822(3), ddn-x25(4), rfc877-x25(5), ethernet-csmacd(6), iso88023-csmacd(7), iso88024-tokenBus(8), iso88025-tokenRing(9), iso88026-man(10), starLan(11), proteon-10Mbit(12), proteon-80Mbit(13), hyperchannel(14), fddi(15), lapb(16), sdlc(17), ds1(18), -- T-1 e1(19), -- european equiv. of T-1 basicISDN(20), primaryISDN(21), -- proprietary serial propPointToPointSerial(22), ppp(23), softwareLoopback(24), eon(25), -- CLNP over IP [11] ethernet-3Mbit(26), nsip(27), -- XNS over IP slip(28), -- generic SLIP ultra(29), -- ULTRA technologies ds3(30), -- T-3 sip(31), -- SMDS frame-relay(32) } ACCESS read-only STATUS mandatory DESCRIPTION "The type of interface, distinguished according to the physical/link protocol(s) immediately `below' the network layer in the protocol stack." ::= { ifEntry 3 } ifMtu OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The size of the largest datagram which can be sent/received on the interface, specified in octets. For interfaces that are used for transmitting network datagrams, this is the size of the largest network datagram that can be sent on the interface." ::= { ifEntry 4 } ifSpeed OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "An estimate of the interface's current bandwidth in bits per second. For interfaces which do not vary in bandwidth or for those where no accurate estimation can be made, this object should contain the nominal bandwidth." ::= { ifEntry 5 } ifPhysAddress OBJECT-TYPE SYNTAX PhysAddress ACCESS read-only STATUS mandatory DESCRIPTION "The interface's address at the protocol layer immediately `below' the network layer in the protocol stack. For interfaces which do not have such an address (e.g., a serial line), this object should contain an octet string of zero length." ::= { ifEntry 6 } ifAdminStatus OBJECT-TYPE SYNTAX INTEGER { up(1), -- ready to pass packets down(2), testing(3) -- in some test mode } ACCESS read-write STATUS mandatory DESCRIPTION "The desired state of the interface. The testing(3) state indicates that no operational packets can be passed." ::= { ifEntry 7 } ifOperStatus OBJECT-TYPE SYNTAX INTEGER { up(1), -- ready to pass packets down(2), testing(3) -- in some test mode } ACCESS read-only STATUS mandatory DESCRIPTION "The current operational state of the interface. The testing(3) state indicates that no operational packets can be passed." ::= { ifEntry 8 } ifLastChange OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "The value of sysUpTime at the time the interface entered its current operational state. If the current state was entered prior to the last re- initialization of the local network management subsystem, then this object contains a zero value." ::= { ifEntry 9 } ifInOctets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of octets received on the interface, including framing characters." ::= { ifEntry 10 } ifInUcastPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of subnetwork-unicast packets delivered to a higher-layer protocol." ::= { ifEntry 11 } ifInNUcastPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of non-unicast (i.e., subnetwork- broadcast or subnetwork-multicast) packets delivered to a higher-layer protocol." ::= { ifEntry 12 } ifInDiscards OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of inbound packets which were chosen to be discarded even though no errors had been detected to prevent their being deliverable to a higher-layer protocol. One possible reason for discarding such a packet could be to free up buffer space." ::= { ifEntry 13 } ifInErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of inbound packets that contained errors preventing them from being deliverable to a higher-layer protocol." ::= { ifEntry 14 } ifInUnknownProtos OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of packets received via the interface which were discarded because of an unknown or unsupported protocol." ::= { ifEntry 15 } ifOutOctets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of octets transmitted out of the interface, including framing characters." ::= { ifEntry 16 } ifOutUcastPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of packets that higher-level protocols requested be transmitted to a subnetwork-unicast address, including those that were discarded or not sent." ::= { ifEntry 17 } ifOutNUcastPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of packets that higher-level protocols requested be transmitted to a non- unicast (i.e., a subnetwork-broadcast or subnetwork-multicast) address, including those that were discarded or not sent." ::= { ifEntry 18 } ifOutDiscards OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of outbound packets which were chosen to be discarded even though no errors had been detected to prevent their being transmitted. One possible reason for discarding such a packet could be to free up buffer space." ::= { ifEntry 19 } ifOutErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of outbound packets that could not be transmitted because of errors." ::= { ifEntry 20 } ifOutQLen OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The length of the output packet queue (in packets)." ::= { ifEntry 21 } ifSpecific OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "A reference to MIB definitions specific to the particular media being used to realize the interface. For example, if the interface is realized by an ethernet, then the value of this object refers to a document defining objects specific to ethernet. If this information is not present, its value should be set to the OBJECT IDENTIFIER { 0 0 }, which is a syntatically valid object identifier, and any conformant implementation of ASN.1 and BER must be able to generate and recognize this value." ::= { ifEntry 22 } -- the Address Translation group -- Implementation of the Address Translation group is -- mandatory for all systems. Note however that this group -- is deprecated by MIB-II. That is, it is being included -- solely for compatibility with MIB-I nodes, and will most -- likely be excluded from MIB-III nodes. From MIB-II and -- onwards, each network protocol group contains its own -- address translation tables. -- The Address Translation group contains one table which is -- the union across all interfaces of the translation tables -- for converting a NetworkAddress (e.g., an IP address) into -- a subnetwork-specific address. For lack of a better term, -- this document refers to such a subnetwork-specific address -- as a `physical' address. -- Examples of such translation tables are: for broadcast -- media where ARP is in use, the translation table is -- equivalent to the ARP cache; or, on an X.25 network where -- non-algorithmic translation to X.121 addresses is -- required, the translation table contains the -- NetworkAddress to X.121 address equivalences. atTable OBJECT-TYPE SYNTAX SEQUENCE OF AtEntry ACCESS not-accessible STATUS deprecated DESCRIPTION "The Address Translation tables contain the NetworkAddress to `physical' address equivalences. Some interfaces do not use translation tables for determining address equivalences (e.g., DDN-X.25 has an algorithmic method); if all interfaces are of this type, then the Address Translation table is empty, i.e., has zero entries." ::= { at 1 } atEntry OBJECT-TYPE SYNTAX AtEntry ACCESS not-accessible STATUS deprecated DESCRIPTION "Each entry contains one NetworkAddress to `physical' address equivalence." INDEX { atIfIndex, atNetAddress } ::= { atTable 1 } AtEntry ::= SEQUENCE { atIfIndex INTEGER, atPhysAddress PhysAddress, atNetAddress NetworkAddress } atIfIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS deprecated DESCRIPTION "The interface on which this entry's equivalence is effective. The interface identified by a particular value of this index is the same interface as identified by the same value of ifIndex." ::= { atEntry 1 } atPhysAddress OBJECT-TYPE SYNTAX PhysAddress ACCESS read-write STATUS deprecated DESCRIPTION "The media-dependent `physical' address. Setting this object to a null string (one of zero length) has the effect of invaliding the corresponding entry in the atTable object. That is, it effectively dissasociates the interface identified with said entry from the mapping identified with said entry. It is an implementation-specific matter as to whether the agent removes an invalidated entry from the table. Accordingly, management stations must be prepared to receive tabular information from agents that corresponds to entries not currently in use. Proper interpretation of such entries requires examination of the relevant atPhysAddress object." ::= { atEntry 2 } atNetAddress OBJECT-TYPE SYNTAX NetworkAddress ACCESS read-write STATUS deprecated DESCRIPTION "The NetworkAddress (e.g., the IP address) corresponding to the media-dependent `physical' address." ::= { atEntry 3 } -- the IP group -- Implementation of the IP group is mandatory for all -- systems. ipForwarding OBJECT-TYPE SYNTAX INTEGER { forwarding(1), -- acting as a gateway not-forwarding(2) -- NOT acting as a gateway } ACCESS read-write STATUS mandatory DESCRIPTION "The indication of whether this entity is acting as an IP gateway in respect to the forwarding of datagrams received by, but not addressed to, this entity. IP gateways forward datagrams. IP hosts do not (except those source-routed via the host). Note that for some managed nodes, this object may take on only a subset of the values possible. Accordingly, it is appropriate for an agent to return a `badValue' response if a management station attempts to change this object to an inappropriate value." ::= { ip 1 } ipDefaultTTL OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The default value inserted into the Time-To-Live field of the IP header of datagrams originated at this entity, whenever a TTL value is not supplied by the transport layer protocol." ::= { ip 2 } ipInReceives OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of input datagrams received from interfaces, including those received in error." ::= { ip 3 } ipInHdrErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of input datagrams discarded due to errors in their IP headers, including bad checksums, version number mismatch, other format errors, time-to-live exceeded, errors discovered in processing their IP options, etc." ::= { ip 4 } ipInAddrErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of input datagrams discarded because the IP address in their IP header's destination field was not a valid address to be received at this entity. This count includes invalid addresses (e.g., 0.0.0.0) and addresses of unsupported Classes (e.g., Class E). For entities which are not IP Gateways and therefore do not forward datagrams, this counter includes datagrams discarded because the destination address was not a local address." ::= { ip 5 } ipForwDatagrams OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of input datagrams for which this entity was not their final IP destination, as a result of which an attempt was made to find a route to forward them to that final destination. In entities which do not act as IP Gateways, this counter will include only those packets which were Source-Routed via this entity, and the Source- Route option processing was successful." ::= { ip 6 } ipInUnknownProtos OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of locally-addressed datagrams received successfully but discarded because of an unknown or unsupported protocol." ::= { ip 7 } ipInDiscards OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of input IP datagrams for which no problems were encountered to prevent their continued processing, but which were discarded (e.g., for lack of buffer space). Note that this counter does not include any datagrams discarded while awaiting re-assembly." ::= { ip 8 } ipInDelivers OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of input datagrams successfully delivered to IP user-protocols (including ICMP)." ::= { ip 9 } ipOutRequests OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of IP datagrams which local IP user-protocols (including ICMP) supplied to IP in requests for transmission. Note that this counter does not include any datagrams counted in ipForwDatagrams." ::= { ip 10 } ipOutDiscards OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of output IP datagrams for which no problem was encountered to prevent their transmission to their destination, but which were discarded (e.g., for lack of buffer space). Note that this counter would include datagrams counted in ipForwDatagrams if any such packets met this (discretionary) discard criterion." ::= { ip 11 } ipOutNoRoutes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of IP datagrams discarded because no route could be found to transmit them to their destination. Note that this counter includes any packets counted in ipForwDatagrams which meet this `no-route' criterion. Note that this includes any datagarms which a host cannot route because all of its default gateways are down." ::= { ip 12 } ipReasmTimeout OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The maximum number of seconds which received fragments are held while they are awaiting reassembly at this entity." ::= { ip 13 } ipReasmReqds OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of IP fragments received which needed to be reassembled at this entity." ::= { ip 14 } ipReasmOKs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of IP datagrams successfully re- assembled." ::= { ip 15 } ipReasmFails OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of failures detected by the IP re- assembly algorithm (for whatever reason: timed out, errors, etc). Note that this is not necessarily a count of discarded IP fragments since some algorithms (notably the algorithm in RFC 815) can lose track of the number of fragments by combining them as they are received." ::= { ip 16 } ipFragOKs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of IP datagrams that have been successfully fragmented at this entity." ::= { ip 17 } ipFragFails OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of IP datagrams that have been discarded because they needed to be fragmented at this entity but could not be, e.g., because their Don't Fragment flag was set." ::= { ip 18 } ipFragCreates OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of IP datagram fragments that have been generated as a result of fragmentation at this entity." ::= { ip 19 } -- the IP address table -- The IP address table contains this entity's IP addressing -- information. ipAddrTable OBJECT-TYPE SYNTAX SEQUENCE OF IpAddrEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The table of addressing information relevant to this entity's IP addresses." ::= { ip 20 } ipAddrEntry OBJECT-TYPE SYNTAX IpAddrEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The addressing information for one of this entity's IP addresses." INDEX { ipAdEntAddr } ::= { ipAddrTable 1 } IpAddrEntry ::= SEQUENCE { ipAdEntAddr IpAddress, ipAdEntIfIndex INTEGER, ipAdEntNetMask IpAddress, ipAdEntBcastAddr INTEGER, ipAdEntReasmMaxSize INTEGER (0..65535) } ipAdEntAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "The IP address to which this entry's addressing information pertains." ::= { ipAddrEntry 1 } ipAdEntIfIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index value which uniquely identifies the interface to which this entry is applicable. The interface identified by a particular value of this index is the same interface as identified by the same value of ifIndex." ::= { ipAddrEntry 2 } ipAdEntNetMask OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "The subnet mask associated with the IP address of this entry. The value of the mask is an IP address with all the network bits set to 1 and all the hosts bits set to 0." ::= { ipAddrEntry 3 } ipAdEntBcastAddr OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The value of the least-significant bit in the IP broadcast address used for sending datagrams on the (logical) interface associated with the IP address of this entry. For example, when the Internet standard all-ones broadcast address is used, the value will be 1. This value applies to both the subnet and network broadcasts addresses used by the entity on this (logical) interface." ::= { ipAddrEntry 4 } ipAdEntReasmMaxSize OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The size of the largest IP datagram which this entity can re-assemble from incoming IP fragmented datagrams received on this interface." ::= { ipAddrEntry 5 } -- the IP routing table -- The IP routing table contains an entry for each route -- presently known to this entity. ipRouteTable OBJECT-TYPE SYNTAX SEQUENCE OF IpRouteEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This entity's IP Routing table." ::= { ip 21 } ipRouteEntry OBJECT-TYPE SYNTAX IpRouteEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A route to a particular destination." INDEX { ipRouteDest } ::= { ipRouteTable 1 } IpRouteEntry ::= SEQUENCE { ipRouteDest IpAddress, ipRouteIfIndex INTEGER, ipRouteMetric1 INTEGER, ipRouteMetric2 INTEGER, ipRouteMetric3 INTEGER, ipRouteMetric4 INTEGER, ipRouteNextHop IpAddress, ipRouteType INTEGER, ipRouteProto INTEGER, ipRouteAge INTEGER, ipRouteMask IpAddress, ipRouteMetric5 INTEGER, ipRouteInfo OBJECT IDENTIFIER } ipRouteDest OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "The destination IP address of this route. An entry with a value of 0.0.0.0 is considered a default route. Multiple routes to a single destination can appear in the table, but access to such multiple entries is dependent on the table- access mechanisms defined by the network management protocol in use." ::= { ipRouteEntry 1 } ipRouteIfIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The index value which uniquely identifies the local interface through which the next hop of this route should be reached. The interface identified by a particular value of this index is the same interface as identified by the same value of ifIndex." ::= { ipRouteEntry 2 } ipRouteMetric1 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The primary routing metric for this route. The semantics of this metric are determined by the routing-protocol specified in the route's ipRouteProto value. If this metric is not used, its value should be set to -1." ::= { ipRouteEntry 3 } ipRouteMetric2 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "An alternate routing metric for this route. The semantics of this metric are determined by the routing-protocol specified in the route's ipRouteProto value. If this metric is not used, its value should be set to -1." ::= { ipRouteEntry 4 } ipRouteMetric3 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "An alternate routing metric for this route. The semantics of this metric are determined by the routing-protocol specified in the route's ipRouteProto value. If this metric is not used, its value should be set to -1." ::= { ipRouteEntry 5 } ipRouteMetric4 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "An alternate routing metric for this route. The semantics of this metric are determined by the routing-protocol specified in the route's ipRouteProto value. If this metric is not used, its value should be set to -1." ::= { ipRouteEntry 6 } ipRouteNextHop OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "The IP address of the next hop of this route. (In the case of a route bound to an interface which is realized via a broadcast media, the value of this field is the agent's IP address on that interface.)" ::= { ipRouteEntry 7 } ipRouteType OBJECT-TYPE SYNTAX INTEGER { other(1), -- none of the following invalid(2), -- an invalidated route -- route to directly direct(3), -- connected (sub-)network -- route to a non-local indirect(4) -- host/network/sub-network } ACCESS read-write STATUS mandatory DESCRIPTION "The type of route. Note that the values direct(3) and indirect(4) refer to the notion of direct and indirect routing in the IP architecture. Setting this object to the value invalid(2) has the effect of invalidating the corresponding entry in the ipRouteTable object. That is, it effectively dissasociates the destination identified with said entry from the route identified with said entry. It is an implementation-specific matter as to whether the agent removes an invalidated entry from the table. Accordingly, management stations must be prepared to receive tabular information from agents that corresponds to entries not currently in use. Proper interpretation of such entries requires examination of the relevant ipRouteType object." ::= { ipRouteEntry 8 } ipRouteProto OBJECT-TYPE SYNTAX INTEGER { other(1), -- none of the following -- non-protocol information, -- e.g., manually configured local(2), -- entries -- set via a network netmgmt(3), -- management protocol -- obtained via ICMP, icmp(4), -- e.g., Redirect -- the remaining values are -- all gateway routing -- protocols egp(5), ggp(6), hello(7), rip(8), is-is(9), es-is(10), ciscoIgrp(11), bbnSpfIgp(12), ospf(13), bgp(14) } ACCESS read-only STATUS mandatory DESCRIPTION "The routing mechanism via which this route was learned. Inclusion of values for gateway routing protocols is not intended to imply that hosts should support those protocols." ::= { ipRouteEntry 9 } ipRouteAge OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The number of seconds since this route was last updated or otherwise determined to be correct. Note that no semantics of `too old' can be implied except through knowledge of the routing protocol by which the route was learned." ::= { ipRouteEntry 10 } ipRouteMask OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the mask to be logical-ANDed with the destination address before being compared to the value in the ipRouteDest field. For those systems that do not support arbitrary subnet masks, an agent constructs the value of the ipRouteMask by determining whether the value of the correspondent ipRouteDest field belong to a class-A, B, or C network, and then using one of: mask network 255.0.0.0 class-A 255.255.0.0 class-B 255.255.255.0 class-C If the value of the ipRouteDest is 0.0.0.0 (a default route), then the mask value is also 0.0.0.0. It should be noted that all IP routing subsystems implicitly use this mechanism." ::= { ipRouteEntry 11 } ipRouteMetric5 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "An alternate routing metric for this route. The semantics of this metric are determined by the routing-protocol specified in the route's ipRouteProto value. If this metric is not used, its value should be set to -1." ::= { ipRouteEntry 12 } ipRouteInfo OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "A reference to MIB definitions specific to the particular routing protocol which is responsible for this route, as determined by the value specified in the route's ipRouteProto value. If this information is not present, its value should be set to the OBJECT IDENTIFIER { 0 0 }, which is a syntatically valid object identifier, and any conformant implementation of ASN.1 and BER must be able to generate and recognize this value." ::= { ipRouteEntry 13 } -- the IP Address Translation table -- The IP address translation table contain the IpAddress to -- `physical' address equivalences. Some interfaces do not -- use translation tables for determining address -- equivalences (e.g., DDN-X.25 has an algorithmic method); -- if all interfaces are of this type, then the Address -- Translation table is empty, i.e., has zero entries. ipNetToMediaTable OBJECT-TYPE SYNTAX SEQUENCE OF IpNetToMediaEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The IP Address Translation table used for mapping from IP addresses to physical addresses." ::= { ip 22 } ipNetToMediaEntry OBJECT-TYPE SYNTAX IpNetToMediaEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry contains one IpAddress to `physical' address equivalence." INDEX { ipNetToMediaIfIndex, ipNetToMediaNetAddress } ::= { ipNetToMediaTable 1 } IpNetToMediaEntry ::= SEQUENCE { ipNetToMediaIfIndex INTEGER, ipNetToMediaPhysAddress PhysAddress, ipNetToMediaNetAddress IpAddress, ipNetToMediaType INTEGER } ipNetToMediaIfIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The interface on which this entry's equivalence is effective. The interface identified by a particular value of this index is the same interface as identified by the same value of ifIndex." ::= { ipNetToMediaEntry 1 } ipNetToMediaPhysAddress OBJECT-TYPE SYNTAX PhysAddress ACCESS read-write STATUS mandatory DESCRIPTION "The media-dependent `physical' address." ::= { ipNetToMediaEntry 2 } ipNetToMediaNetAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "The IpAddress corresponding to the media- dependent `physical' address." ::= { ipNetToMediaEntry 3 } ipNetToMediaType OBJECT-TYPE SYNTAX INTEGER { other(1), -- none of the following invalid(2), -- an invalidated mapping dynamic(3), static(4) } ACCESS read-write STATUS mandatory DESCRIPTION "The type of mapping. Setting this object to the value invalid(2) has the effect of invalidating the corresponding entry in the ipNetToMediaTable. That is, it effectively dissasociates the interface identified with said entry from the mapping identified with said entry. It is an implementation-specific matter as to whether the agent removes an invalidated entry from the table. Accordingly, management stations must be prepared to receive tabular information from agents that corresponds to entries not currently in use. Proper interpretation of such entries requires examination of the relevant ipNetToMediaType object." ::= { ipNetToMediaEntry 4 } -- additional IP objects ipRoutingDiscards OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of routing entries which were chosen to be discarded even though they are valid. One possible reason for discarding such an entry could be to free-up buffer space for other routing entries." ::= { ip 23 } -- the ICMP group -- Implementation of the ICMP group is mandatory for all -- systems. icmpInMsgs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of ICMP messages which the entity received. Note that this counter includes all those counted by icmpInErrors." ::= { icmp 1 } icmpInErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of ICMP messages which the entity received but determined as having ICMP-specific errors (bad ICMP checksums, bad length, etc.)." ::= { icmp 2 } icmpInDestUnreachs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of ICMP Destination Unreachable messages received." ::= { icmp 3 } icmpInTimeExcds OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of ICMP Time Exceeded messages received." ::= { icmp 4 } icmpInParmProbs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of ICMP Parameter Problem messages received." ::= { icmp 5 } icmpInSrcQuenchs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of ICMP Source Quench messages received." ::= { icmp 6 } icmpInRedirects OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of ICMP Redirect messages received." ::= { icmp 7 } icmpInEchos OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of ICMP Echo (request) messages received." ::= { icmp 8 } icmpInEchoReps OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of ICMP Echo Reply messages received." ::= { icmp 9 } icmpInTimestamps OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of ICMP Timestamp (request) messages received." ::= { icmp 10 } icmpInTimestampReps OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of ICMP Timestamp Reply messages received." ::= { icmp 11 } icmpInAddrMasks OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of ICMP Address Mask Request messages received." ::= { icmp 12 } icmpInAddrMaskReps OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of ICMP Address Mask Reply messages received." ::= { icmp 13 } icmpOutMsgs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of ICMP messages which this entity attempted to send. Note that this counter includes all those counted by icmpOutErrors." ::= { icmp 14 } icmpOutErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of ICMP messages which this entity did not send due to problems discovered within ICMP such as a lack of buffers. This value should not include errors discovered outside the ICMP layer such as the inability of IP to route the resultant datagram. In some implementations there may be no types of error which contribute to this counter's value." ::= { icmp 15 } icmpOutDestUnreachs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of ICMP Destination Unreachable messages sent." ::= { icmp 16 } icmpOutTimeExcds OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of ICMP Time Exceeded messages sent." ::= { icmp 17 } icmpOutParmProbs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of ICMP Parameter Problem messages sent." ::= { icmp 18 } icmpOutSrcQuenchs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of ICMP Source Quench messages sent." ::= { icmp 19 } icmpOutRedirects OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of ICMP Redirect messages sent. For a host, this object will always be zero, since hosts do not send redirects." ::= { icmp 20 } icmpOutEchos OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of ICMP Echo (request) messages sent." ::= { icmp 21 } icmpOutEchoReps OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of ICMP Echo Reply messages sent." ::= { icmp 22 } icmpOutTimestamps OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of ICMP Timestamp (request) messages sent." ::= { icmp 23 } icmpOutTimestampReps OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of ICMP Timestamp Reply messages sent." ::= { icmp 24 } icmpOutAddrMasks OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of ICMP Address Mask Request messages sent." ::= { icmp 25 } icmpOutAddrMaskReps OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of ICMP Address Mask Reply messages sent." ::= { icmp 26 } -- the TCP group -- Implementation of the TCP group is mandatory for all -- systems that implement the TCP. -- Note that instances of object types that represent -- information about a particular TCP connection are -- transient; they persist only as long as the connection -- in question. tcpRtoAlgorithm OBJECT-TYPE SYNTAX INTEGER { other(1), -- none of the following constant(2), -- a constant rto rsre(3), -- MIL-STD-1778, Appendix B vanj(4) -- Van Jacobson's algorithm [10] } ACCESS read-only STATUS mandatory DESCRIPTION "The algorithm used to determine the timeout value used for retransmitting unacknowledged octets." ::= { tcp 1 } tcpRtoMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The minimum value permitted by a TCP implementation for the retransmission timeout, measured in milliseconds. More refined semantics for objects of this type depend upon the algorithm used to determine the retransmission timeout. In particular, when the timeout algorithm is rsre(3), an object of this type has the semantics of the LBOUND quantity described in RFC 793." ::= { tcp 2 } tcpRtoMax OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The maximum value permitted by a TCP implementation for the retransmission timeout, measured in milliseconds. More refined semantics for objects of this type depend upon the algorithm used to determine the retransmission timeout. In particular, when the timeout algorithm is rsre(3), an object of this type has the semantics of the UBOUND quantity described in RFC 793." ::= { tcp 3 } tcpMaxConn OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The limit on the total number of TCP connections the entity can support. In entities where the maximum number of connections is dynamic, this object should contain the value -1." ::= { tcp 4 } tcpActiveOpens OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of times TCP connections have made a direct transition to the SYN-SENT state from the CLOSED state." ::= { tcp 5 } tcpPassiveOpens OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of times TCP connections have made a direct transition to the SYN-RCVD state from the LISTEN state." ::= { tcp 6 } tcpAttemptFails OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of times TCP connections have made a direct transition to the CLOSED state from either the SYN-SENT state or the SYN-RCVD state, plus the number of times TCP connections have made a direct transition to the LISTEN state from the SYN-RCVD state." ::= { tcp 7 } tcpEstabResets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of times TCP connections have made a direct transition to the CLOSED state from either the ESTABLISHED state or the CLOSE-WAIT state." ::= { tcp 8 } tcpCurrEstab OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The number of TCP connections for which the current state is either ESTABLISHED or CLOSE- WAIT." ::= { tcp 9 } tcpInSegs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of segments received, including those received in error. This count includes segments received on currently established connections." ::= { tcp 10 } tcpOutSegs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of segments sent, including those on current connections but excluding those containing only retransmitted octets." ::= { tcp 11 } tcpRetransSegs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of segments retransmitted - that is, the number of TCP segments transmitted containing one or more previously transmitted octets." ::= { tcp 12 } -- the TCP Connection table -- The TCP connection table contains information about this -- entity's existing TCP connections. tcpConnTable OBJECT-TYPE SYNTAX SEQUENCE OF TcpConnEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table containing TCP connection-specific information." ::= { tcp 13 } tcpConnEntry OBJECT-TYPE SYNTAX TcpConnEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Information about a particular current TCP connection. An object of this type is transient, in that it ceases to exist when (or soon after) the connection makes the transition to the CLOSED state." INDEX { tcpConnLocalAddress, tcpConnLocalPort, tcpConnRemAddress, tcpConnRemPort } ::= { tcpConnTable 1 } TcpConnEntry ::= SEQUENCE { tcpConnState INTEGER, tcpConnLocalAddress IpAddress, tcpConnLocalPort INTEGER (0..65535), tcpConnRemAddress IpAddress, tcpConnRemPort INTEGER (0..65535) } tcpConnState OBJECT-TYPE SYNTAX INTEGER { closed(1), listen(2), synSent(3), synReceived(4), established(5), finWait1(6), finWait2(7), closeWait(8), lastAck(9), closing(10), timeWait(11), deleteTCB(12) } ACCESS read-write STATUS mandatory DESCRIPTION "The state of this TCP connection. The only value which may be set by a management station is deleteTCB(12). Accordingly, it is appropriate for an agent to return a `badValue' response if a management station attempts to set this object to any other value. If a management station sets this object to the value deleteTCB(12), then this has the effect of deleting the TCB (as defined in RFC 793) of the corresponding connection on the managed node, resulting in immediate termination of the connection. As an implementation-specific option, a RST segment may be sent from the managed node to the other TCP endpoint (note however that RST segments are not sent reliably)." ::= { tcpConnEntry 1 } tcpConnLocalAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "The local IP address for this TCP connection. In the case of a connection in the listen state which is willing to accept connections for any IP interface associated with the node, the value 0.0.0.0 is used." ::= { tcpConnEntry 2 } tcpConnLocalPort OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The local port number for this TCP connection." ::= { tcpConnEntry 3 } tcpConnRemAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "The remote IP address for this TCP connection." ::= { tcpConnEntry 4 } tcpConnRemPort OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The remote port number for this TCP connection." ::= { tcpConnEntry 5 } -- additional TCP objects tcpInErrs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of segments received in error (e.g., bad TCP checksums)." ::= { tcp 14 } tcpOutRsts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of TCP segments sent containing the RST flag." ::= { tcp 15 } -- the UDP group -- Implementation of the UDP group is mandatory for all -- systems which implement the UDP. udpInDatagrams OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of UDP datagrams delivered to UDP users." ::= { udp 1 } udpNoPorts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of received UDP datagrams for which there was no application at the destination port." ::= { udp 2 } udpInErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of received UDP datagrams that could not be delivered for reasons other than the lack of an application at the destination port." ::= { udp 3 } udpOutDatagrams OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of UDP datagrams sent from this entity." ::= { udp 4 } -- the UDP Listener table -- The UDP listener table contains information about this -- entity's UDP end-points on which a local application is -- currently accepting datagrams. udpTable OBJECT-TYPE SYNTAX SEQUENCE OF UdpEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table containing UDP listener information." ::= { udp 5 } udpEntry OBJECT-TYPE SYNTAX UdpEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Information about a particular current UDP listener." INDEX { udpLocalAddress, udpLocalPort } ::= { udpTable 1 } UdpEntry ::= SEQUENCE { udpLocalAddress IpAddress, udpLocalPort INTEGER (0..65535) } udpLocalAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "The local IP address for this UDP listener. In the case of a UDP listener which is willing to accept datagrams for any IP interface associated with the node, the value 0.0.0.0 is used." ::= { udpEntry 1 } udpLocalPort OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The local port number for this UDP listener." ::= { udpEntry 2 } -- the EGP group -- Implementation of the EGP group is mandatory for all -- systems which implement the EGP. -- the EGP Neighbor table -- The EGP neighbor table contains information about this -- entity's EGP neighbors. -- additional EGP objects -- the Transmission group -- Based on the transmission media underlying each interface -- on a system, the corresponding portion of the Transmission -- group is mandatory for that system. -- When Internet-standard definitions for managing -- transmission media are defined, the transmission group is -- used to provide a prefix for the names of those objects. -- Typically, such definitions reside in the experimental -- portion of the MIB until they are "proven", then as a -- part of the Internet standardization process, the -- definitions are accordingly elevated and a new object -- identifier, under the transmission group is defined. By -- convention, the name assigned is: -- -- type OBJECT IDENTIFIER ::= { transmission number } -- -- where "type" is the symbolic value used for the media in -- the ifType column of the ifTable object, and "number" is -- the actual integer value corresponding to the symbol. -- the SNMP group -- Implementation of the SNMP group is mandatory for all -- systems which support an SNMP protocol entity. Some of -- the objects defined below will be zero-valued in those -- SNMP implementations that are optimized to support only -- those functions specific to either a management agent or -- a management station. In particular, it should be -- observed that the objects below refer to an SNMP entity, -- and there may be several SNMP entities residing on a -- managed node (e.g., if the node is hosting acting as -- a management station). snmpInPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of Messages delivered to the SNMP entity from the transport service." ::= { snmp 1 } snmpOutPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of SNMP Messages which were passed from the SNMP protocol entity to the transport service." ::= { snmp 2 } snmpInBadVersions OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of SNMP Messages which were delivered to the SNMP protocol entity and were for an unsupported SNMP version." ::= { snmp 3 } snmpInBadCommunityNames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of SNMP Messages delivered to the SNMP protocol entity which used a SNMP community name not known to said entity." ::= { snmp 4 } snmpInBadCommunityUses OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of SNMP Messages delivered to the SNMP protocol entity which represented an SNMP operation which was not allowed by the SNMP community named in the Message." ::= { snmp 5 } snmpInASNParseErrs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of ASN.1 or BER errors encountered by the SNMP protocol entity when decoding received SNMP Messages." ::= { snmp 6 } -- { snmp 7 } is not used snmpInTooBigs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of SNMP PDUs which were delivered to the SNMP protocol entity and for which the value of the error-status field is `tooBig'." ::= { snmp 8 } snmpInNoSuchNames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of SNMP PDUs which were delivered to the SNMP protocol entity and for which the value of the error-status field is `noSuchName'." ::= { snmp 9 } snmpInBadValues OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of SNMP PDUs which were delivered to the SNMP protocol entity and for which the value of the error-status field is `badValue'." ::= { snmp 10 } snmpInReadOnlys OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number valid SNMP PDUs which were delivered to the SNMP protocol entity and for which the value of the error-status field is `readOnly'. It should be noted that it is a protocol error to generate an SNMP PDU which contains the value `readOnly' in the error-status field, as such this object is provided as a means of detecting incorrect implementations of the SNMP." ::= { snmp 11 } snmpInGenErrs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of SNMP PDUs which were delivered to the SNMP protocol entity and for which the value of the error-status field is `genErr'." ::= { snmp 12 } snmpInTotalReqVars OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of MIB objects which have been retrieved successfully by the SNMP protocol entity as the result of receiving valid SNMP Get-Request and Get-Next PDUs." ::= { snmp 13 } snmpInTotalSetVars OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of MIB objects which have been altered successfully by the SNMP protocol entity as the result of receiving valid SNMP Set-Request PDUs." ::= { snmp 14 } snmpInGetRequests OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of SNMP Get-Request PDUs which have been accepted and processed by the SNMP protocol entity." ::= { snmp 15 } snmpInGetNexts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of SNMP Get-Next PDUs which have been accepted and processed by the SNMP protocol entity." ::= { snmp 16 } snmpInSetRequests OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of SNMP Set-Request PDUs which have been accepted and processed by the SNMP protocol entity." ::= { snmp 17 } snmpInGetResponses OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of SNMP Get-Response PDUs which have been accepted and processed by the SNMP protocol entity." ::= { snmp 18 } snmpInTraps OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of SNMP Trap PDUs which have been accepted and processed by the SNMP protocol entity." ::= { snmp 19 } snmpOutTooBigs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of SNMP PDUs which were generated by the SNMP protocol entity and for which the value of the error-status field is `tooBig.'" ::= { snmp 20 } snmpOutNoSuchNames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of SNMP PDUs which were generated by the SNMP protocol entity and for which the value of the error-status is `noSuchName'." ::= { snmp 21 } snmpOutBadValues OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of SNMP PDUs which were generated by the SNMP protocol entity and for which the value of the error-status field is `badValue'." ::= { snmp 22 } -- { snmp 23 } is not used snmpOutGenErrs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of SNMP PDUs which were generated by the SNMP protocol entity and for which the value of the error-status field is `genErr'." ::= { snmp 24 } snmpOutGetRequests OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of SNMP Get-Request PDUs which have been generated by the SNMP protocol entity." ::= { snmp 25 } snmpOutGetNexts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of SNMP Get-Next PDUs which have been generated by the SNMP protocol entity." ::= { snmp 26 } snmpOutSetRequests OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of SNMP Set-Request PDUs which have been generated by the SNMP protocol entity." ::= { snmp 27 } snmpOutGetResponses OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of SNMP Get-Response PDUs which have been generated by the SNMP protocol entity." ::= { snmp 28 } snmpOutTraps OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of SNMP Trap PDUs which have been generated by the SNMP protocol entity." ::= { snmp 29 } snmpEnableAuthenTraps OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Indicates whether the SNMP agent process is permitted to generate authentication-failure traps. The value of this object overrides any configuration information; as such, it provides a means whereby all authentication-failure traps may be disabled. Note that it is strongly recommended that this object be stored in non-volatile memory so that it remains constant between re-initializations of the network management system." ::= { snmp 30 } -- -- FILE: /bigguy/users/craig/mibs/src/rfc/rfc1215.smi -- -- Changes for rfc1215 (Concise TRAP): -- Added MODULE definition. -- Commented out TRAP-TYPE macro definition and replaced -- with SMIC directive to enable it. -- Make builtin items known -- SMI TRAP-TYPE -- TRAP-TYPE MACRO ::= -- BEGIN -- TYPE NOTATION ::= "ENTERPRISE" value -- (enterprise OBJECT IDENTIFIER) -- VarPart -- DescrPart -- ReferPart -- VALUE NOTATION ::= value (VALUE INTEGER) -- -- VarPart ::= -- "VARIABLES" "{" VarTypes "}" -- | empty -- VarTypes ::= -- VarType | VarTypes "," VarType -- VarType ::= -- value (vartype ObjectName) -- -- DescrPart ::= -- "DESCRIPTION" value (description DisplayString) -- | empty -- -- ReferPart ::= -- "REFERENCE" value (reference DisplayString) -- | empty -- -- END -- -- FILE: /bigguy/users/craig/mibs/src/rfc/rfc1286.mib -- -- Changes to RFC1286 (Bridge MIB): -- Removed imported but unused Gauge. -- RFC1286 -- December 91 -- All representations of MAC addresses in this MIB Module use, -- as a textual convention (i.e. this convention does not affect -- their encoding), the data type: MacAddress ::= OCTET STRING (SIZE (6)) -- a 6 octet address in -- the "canonical" order -- defined by IEEE 802.1a, i.e., as if it were transmitted least -- significant bit first, even though 802.5 (in contrast to other -- 802.x protocols) requires MAC addresses to be transmitted most -- significant bit first. -- -- 16-bit addresses, if needed, are represented by setting their -- upper 4 octets to all 0's, i.e., AAFF would be represented -- as 00000000AAFF. -- Similarly, all representations of Bridge-Id in this MIB Module -- use, as a textual convention (i.e. this convention does not affect -- their encoding), the data type: BridgeId ::= OCTET STRING (SIZE (8)) -- the Bridge-Identifier as -- used in the Spanning Tree -- Protocol to uniquely identify a bridge. Its first two octets -- (in network byte order) contain a priority value and its last -- 6 octets contain the MAC address used to refer to a bridge in a -- unique fashion (typically, the numerically smallest MAC address -- of all ports on the bridge). -- Several objects in this MIB module represent values of timers -- used by the Spanning Tree Protocol. In this MIB, these timers -- have values in units of hundreths of a second (i.e. 1/100 secs). -- These timers, when stored in a Spanning Tree Protocol's BPDU, -- are in units of 1/256 seconds. Note, however, that 802.1d/D9 -- specifies a settable granularity of no more than 1 second for -- these timers. To avoid ambiguity, a data type is defined here -- as a textual convention and all representation of these timers -- in this MIB module are defined using this data type. An algorithm -- is also defined for converting between the different units, to -- ensure a timer's value is not distorted by multiple conversions. -- The data type is: Timeout ::= INTEGER -- a STP timer in units of 1/100 seconds -- To convert a Timeout value into a value in units of -- 1/256 seconds, the following algorithm should be used: -- -- b = floor( (n * 256) / 100) -- -- where: -- floor = quotient [ignore remainder] -- n is the value in 1/100 second units -- b is the value in 1/256 second units -- -- To convert the value from 1/256 second units back to -- 1/100 seconds, the following algorithm should be used: -- -- n = ceiling( (b * 100) / 256) -- -- where: -- ceiling = quotient [if remainder is 0], or -- quotient + 1 [if remainder is non-zero] -- n is the value in 1/100 second units -- b is the value in 1/256 second units -- -- Note: it is important that the arithmetic operations are done -- in the order specified (i.e., multiply first, divide second). dot1dBridge OBJECT IDENTIFIER ::= { mib-2 17 } -- groups in the Bridge MIB dot1dBase OBJECT IDENTIFIER ::= { dot1dBridge 1 } dot1dStp OBJECT IDENTIFIER ::= { dot1dBridge 2 } dot1dSr OBJECT IDENTIFIER ::= { dot1dBridge 3 } dot1dTp OBJECT IDENTIFIER ::= { dot1dBridge 4 } dot1dStatic OBJECT IDENTIFIER ::= { dot1dBridge 5 } -- the dot1dBase group -- Implementation of the dot1dBase group is mandatory for all -- bridges. -- The Generic Bridge Port Table -- the dot1dStp group -- Implementation of the dot1dStp group is optional. It is -- implemented by those bridges that support the Spanning Tree -- Protocol. Transparent, Source Route, and SRT bridges will -- implement this group only if they support the Spanning Tree -- Protocol. -- The Spanning Tree Port Table -- the dot1dSr group -- Implementation of the dot1dSr group is optional. It is -- implemented by those bridges that support the source route -- bridging mode, including Source Route and SRT bridges. -- It would be nice if we could use ifMtu as the size of the -- largest frame, but we can't because ifMtu is defined to be -- the size that the (inter-)network layer can use which can -- differ from the MAC layer (especially if several layers of -- encapsulation are used). -- the dot1dTp group -- Implementation of the dot1dTp group is optional. It is -- implemented by those bridges that support the transparent -- bridging mode. A transparent or SRT bridge will implement -- this group. -- The Forwarding Database for Transparent Bridges -- Port Table for Transparent Bridges -- It would be nice if we could use ifMtu as the size of the -- largest INFO field, but we can't because ifMtu is defined -- to be the size that the (inter-)network layer can use which -- can differ from the MAC layer (especially if several layers -- of encapsulation are used). -- The Static (Destination-Address Filtering) Database -- Implementation of this group is optional. -- Traps for use by Bridges -- Traps for the Spanning Tree Protocol newRoot TRAP-TYPE ENTERPRISE dot1dBridge DESCRIPTION "The newRoot trap indicates that the sending agent has become the new root of the Spanning Tree; the trap is sent by a bridge soon after its election as the new root, e.g., upon expiration of the Topology Change Timer immediately subsequent to its election." ::= 1 topologyChange TRAP-TYPE ENTERPRISE dot1dBridge DESCRIPTION "A topologyChange trap is sent by a bridge when any of its configured ports transitions from the Learning state to the Forwarding state, or from the Forwarding state to the Blocking state. The trap is not sent if a newRoot trap is sent for the same transition." ::= 2 -- -- FILE: /bigguy/users/craig/mibs/src/rfc/rfc1368.mib -- -- IMPORTed MacAddress from RFC1286 snmpDot3RptrMgt OBJECT IDENTIFIER ::= { mib-2 22 } -- All representations of MAC addresses in this MIB Module use, -- as a textual convention (i.e., this convention does not affect -- their encoding), the data type: -- MacAddress ::= OCTET STRING (SIZE (6)) -- a 6 octet address in the "canonical" order -- defined by IEEE 802.1a, i.e., as if it were transmitted least -- significant bit first. -- References -- -- The following references are used throughout this MIB: -- -- [IEEE 802.3 Std] -- refers to IEEE 802.3/ISO 8802-3 Information processing -- systems - Local area networks - Part 3: Carrier sense -- multiple access with collision detection (CSMA/CD) -- access method and physical layer specifications -- (2nd edition, September 21, 1990). -- -- [IEEE 802.3 Rptr Mgt] -- refers to IEEE P802.3K, 'Layer Management for 10 Mb/s -- Baseband Repeaters, Section 19,' Draft Supplement to -- ANSI/IEEE 802.3, (Draft 8, April 9, 1992) -- MIB Groups -- -- The rptrBasicPackage group is mandatory. -- The rptrMonitorPackage and rptrAddrTrackPackage -- groups are optional. rptrBasicPackage OBJECT IDENTIFIER ::= { snmpDot3RptrMgt 1 } rptrMonitorPackage OBJECT IDENTIFIER ::= { snmpDot3RptrMgt 2 } rptrAddrTrackPackage OBJECT IDENTIFIER ::= { snmpDot3RptrMgt 3 } -- object identifiers for organizing the information -- in the groups by repeater, port-group, and port rptrRptrInfo OBJECT IDENTIFIER ::= { rptrBasicPackage 1 } rptrGroupInfo OBJECT IDENTIFIER ::= { rptrBasicPackage 2 } rptrPortInfo OBJECT IDENTIFIER ::= { rptrBasicPackage 3 } rptrMonitorRptrInfo OBJECT IDENTIFIER ::= { rptrMonitorPackage 1 } rptrMonitorGroupInfo OBJECT IDENTIFIER ::= { rptrMonitorPackage 2 } rptrMonitorPortInfo OBJECT IDENTIFIER ::= { rptrMonitorPackage 3 } rptrAddrTrackRptrInfo -- this subtree is currently unused OBJECT IDENTIFIER ::= { rptrAddrTrackPackage 1 } rptrAddrTrackGroupInfo -- this subtree is currently unused OBJECT IDENTIFIER ::= { rptrAddrTrackPackage 2 } rptrAddrTrackPortInfo OBJECT IDENTIFIER ::= { rptrAddrTrackPackage 3 } -- -- The BASIC GROUP -- -- Implementation of the Basic Group is mandatory for all -- managed repeaters. -- -- Basic Repeater Information -- -- Configuration, status, and control objects for the overall -- repeater -- rptrGroupCapacity OBJECT-TYPE SYNTAX INTEGER (1..1024) ACCESS read-only STATUS mandatory DESCRIPTION "The rptrGroupCapacity is the number of groups that can be contained within the repeater. Within each managed repeater, the groups are uniquely numbered in the range from 1 to rptrGroupCapacity. Some groups may not be present in the repeater, in which case the actual number of groups present will be less than rptrGroupCapacity. The number of groups present will never be greater than rptrGroupCapacity. Note: In practice, this will generally be the number of field-replaceable units (i.e., modules, cards, or boards) that can fit in the physical repeater enclosure, and the group numbers will correspond to numbers marked on the physical enclosure." REFERENCE "Reference IEEE 802.3 Rptr Mgt, 19.2.3.2, aRepeaterGroupCapacity." ::= { rptrRptrInfo 1 } rptrOperStatus OBJECT-TYPE SYNTAX INTEGER { other(1), -- undefined or unknown status ok(2), -- no known failures rptrFailure(3), -- repeater-related failure groupFailure(4), -- group-related failure portFailure(5), -- port-related failure generalFailure(6) -- failure, unspecified type } ACCESS read-only STATUS mandatory DESCRIPTION "The rptrOperStatus object indicates the operational state of the repeater. The rptrHealthText object may be consulted for more specific information about the state of the repeater's health. In the case of multiple kinds of failures (e.g., repeater failure and port failure), the value of this attribute shall reflect the highest priority failure in the following order: rptrFailure(3) groupFailure(4) portFailure(5) generalFailure(6)." REFERENCE "Reference IEEE 802.3 Rptr Mgt, 19.2.3.2, aRepeaterHealthState." ::= { rptrRptrInfo 2 } rptrHealthText OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "The health text object is a text string that provides information relevant to the operational state of the repeater. Agents may use this string to provide detailed information on current failures, including how they were detected, and/or instructions for problem resolution. The contents are agent-specific." REFERENCE "Reference IEEE 802.3 Rptr Mgt, 19.2.3.2, aRepeaterHealthText." ::= { rptrRptrInfo 3 } rptrReset OBJECT-TYPE SYNTAX INTEGER { noReset(1), reset(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Setting this object to reset(2) causes a transition to the START state of Fig 9-2 in section 9 [IEEE 802.3 Std]. Setting this object to noReset(1) has no effect. The agent will always return the value noReset(1) when this object is read. This action does not reset the management counters defined in this document nor does it affect the portAdminStatus parameters. Included in this action is the execution of a disruptive Self-Test with the following characteristics: a) The nature of the tests is not specified. b) The test resets the repeater but without affecting management information about the repeater. c) The test does not inject packets onto any segment. d) Packets received during the test may or may not be transferred. e) The test does not interfere with management functions. As a result of this action a rptrResetEvent trap should be sent." REFERENCE "Reference IEEE 802.3 Rptr Mgt, 19.2.3.3, acResetRepeater." ::= { rptrRptrInfo 4 } rptrNonDisruptTest OBJECT-TYPE SYNTAX INTEGER { noSelfTest(1), selfTest(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Setting this object to selfTest(2) causes the repeater to perform a agent-specific, non- disruptive self-test that has the following characteristics: a) The nature of the tests is not specified. b) The test does not change the state of the repeater or management information about the repeater. c) The test does not inject packets onto any segment. d) The test does not prevent the relay of any packets. e) The test does not interfere with management functions. After performing this test the agent will update the repeater health information and send a rptrHealth trap. Setting this object to noSelfTest(1) has no effect. The agent will always return the value noSelfTest(1) when this object is read." REFERENCE "Reference IEEE 802.3 Rptr Mgt, 19.2.3.3, acExecuteNonDisruptiveSelfTest." ::= { rptrRptrInfo 5 } rptrTotalPartitionedPorts OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "This object returns the total number of ports in the repeater whose current state meets all three of the following criteria: rptrPortOperStatus does not have the value notPresent(3), rptrPortAdminStatus is enabled(1), and rptrPortAutoPartitionState is autoPartitioned(2)." ::= { rptrRptrInfo 6 } -- -- The Basic Port Group Table -- rptrGroupTable OBJECT-TYPE SYNTAX SEQUENCE OF RptrGroupEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of descriptive and status information about the groups of ports." ::= { rptrGroupInfo 1 } rptrGroupEntry OBJECT-TYPE SYNTAX RptrGroupEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the table, containing information about a single group of ports." INDEX { rptrGroupIndex } ::= { rptrGroupTable 1 } RptrGroupEntry ::= SEQUENCE { rptrGroupIndex INTEGER, rptrGroupDescr DisplayString, rptrGroupObjectID OBJECT IDENTIFIER, rptrGroupOperStatus INTEGER, rptrGroupLastOperStatusChange TimeTicks, rptrGroupPortCapacity INTEGER } rptrGroupIndex OBJECT-TYPE SYNTAX INTEGER (1..1024) ACCESS read-only STATUS mandatory DESCRIPTION "This object identifies the group within the repeater for which this entry contains information. This value is never greater than rptrGroupCapacity." REFERENCE "Reference IEEE 802.3 Rptr Mgt, 19.2.5.2, aGroupID." ::= { rptrGroupEntry 1 } rptrGroupDescr OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "A textual description of the group. This value should include the full name and version identification of the group's hardware type and indicate how the group is differentiated from other groups in the repeater. Plug-in Module, Rev A' or 'Barney Rubble 10BASE-T 4-port SIMM socket Version 2.1' are examples of valid group descriptions. It is mandatory that this only contain printable ASCII characters." ::= { rptrGroupEntry 2 } rptrGroupObjectID OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The vendor's authoritative identification of the group. This value is allocated within the SMI enterprises subtree (1.3.6.1.4.1) and provides a straight-forward and unambiguous means for determining what kind of group is being managed. For example, this object could take the value 1.3.6.1.4.1.4242.1.2.14 if vendor 'Flintstones, Inc.' was assigned the subtree 1.3.6.1.4.1.4242, and had assigned the identifier 1.3.6.1.4.1.4242.1.2.14 to its 'Wilma Flintstone 6-Port FOIRL Plug-in Module.'" ::= { rptrGroupEntry 3 } rptrGroupOperStatus OBJECT-TYPE SYNTAX INTEGER { other(1), operational(2), malfunctioning(3), notPresent(4), underTest(5), resetInProgress(6) } ACCESS read-only STATUS mandatory DESCRIPTION "An object that indicates the operational status of the group. A status of notPresent(4) indicates that the group is temporarily or permanently physically and/or logically not a part of the repeater. It is an implementation-specific matter as to whether the agent effectively removes notPresent entries from the table. A status of operational(2) indicates that the group is functioning, and a status of malfunctioning(3) indicates that the group is malfunctioning in some way." ::= { rptrGroupEntry 4 } rptrGroupLastOperStatusChange OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "An object that contains the value of sysUpTime at the time that the value of the rptrGroupOperStatus object for this group last changed. A value of zero indicates that the group's oper status has not changed since the agent last restarted." ::= { rptrGroupEntry 5 } rptrGroupPortCapacity OBJECT-TYPE SYNTAX INTEGER (1..1024) ACCESS read-only STATUS mandatory DESCRIPTION "The rptrGroupPortCapacity is the number of ports that can be contained within the group. Valid range is 1-1024. Within each group, the ports are uniquely numbered in the range from 1 to rptrGroupPortCapacity. Note: In practice, this will generally be the number of ports on a module, card, or board, and the port numbers will correspond to numbers marked on the physical embodiment." REFERENCE "Reference IEEE 802.3 Rptr Mgt, 19.2.5.2, aGroupPortCapacity." ::= { rptrGroupEntry 6 } -- -- The Basic Port Table -- rptrPortTable OBJECT-TYPE SYNTAX SEQUENCE OF RptrPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of descriptive and status information about the ports." ::= { rptrPortInfo 1 } rptrPortEntry OBJECT-TYPE SYNTAX RptrPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the table, containing information about a single port." INDEX { rptrPortGroupIndex, rptrPortIndex } ::= { rptrPortTable 1 } RptrPortEntry ::= SEQUENCE { rptrPortGroupIndex INTEGER, rptrPortIndex INTEGER, rptrPortAdminStatus INTEGER, rptrPortAutoPartitionState INTEGER, rptrPortOperStatus INTEGER } rptrPortGroupIndex OBJECT-TYPE SYNTAX INTEGER (1..1024) ACCESS read-only STATUS mandatory DESCRIPTION "This object identifies the group containing the port for which this entry contains information." ::= { rptrPortEntry 1 } rptrPortIndex OBJECT-TYPE SYNTAX INTEGER (1..1024) ACCESS read-only STATUS mandatory DESCRIPTION "This object identifies the port within the group for which this entry contains information. This value can never be greater than rptrGroupPortCapacity for the associated group." REFERENCE "Reference IEEE 802.3 Rptr Mgt, 19.2.6.2, aPortID." ::= { rptrPortEntry 2 } rptrPortAdminStatus OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Setting this object to disabled(2) disables the port. A disabled port neither transmits nor receives. Once disabled, a port must be explicitly enabled to restore operation. A port which is disabled when power is lost or when a reset is exerted shall remain disabled when normal operation resumes. The admin status takes precedence over auto- partition and functionally operates between the auto-partition mechanism and the AUI/PMA. Setting this object to enabled(1) enables the port and exerts a BEGIN on the port's auto-partition state machine. (In effect, when a port is disabled, the value of rptrPortAutoPartitionState for that port is frozen until the port is next enabled. When the port becomes enabled, the rptrPortAutoPartitionState becomes notAutoPartitioned(1), regardless of its pre-disabling state.)" REFERENCE "Reference IEEE 802.3 Rptr Mgt, 19.2.6.2, aPortAdminState and 19.2.6.3, acPortAdminControl." ::= { rptrPortEntry 3 } rptrPortAutoPartitionState OBJECT-TYPE SYNTAX INTEGER { notAutoPartitioned(1), autoPartitioned(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The autoPartitionState flag indicates whether the port is currently partitioned by the repeater's auto-partition protection. The conditions that cause port partitioning are specified in partition state machine in Section 9 [IEEE 802.3 Std]. They are not differentiated here." REFERENCE "Reference IEEE 802.3 Rptr Mgt, 19.2.6.2, aAutoPartitionState." ::= { rptrPortEntry 4 } rptrPortOperStatus OBJECT-TYPE SYNTAX INTEGER { operational(1), notOperational(2), notPresent(3) } ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the port's operational status. The notPresent(3) status indicates the port is physically removed (note this may or may not be possible depending on the type of port.) The operational(1) status indicates that the port is enabled (see rptrPortAdminStatus) and working, even though it might be auto-partitioned (see rptrPortAutoPartitionState). If this object has the value operational(1) and rptrPortAdminStatus is set to disabled(2), it is expected that this object's value will change to notOperational(2) soon after." ::= { rptrPortEntry 5 } -- -- The MONITOR GROUP -- -- Implementation of this group is optional, but within the -- group all elements are mandatory. If a managed repeater -- implements any part of this group, the entire group shall -- be implemented. -- -- Repeater Monitor Information -- -- Performance monitoring statistics for the repeater -- rptrMonitorTransmitCollisions OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This counter is incremented every time the repeater state machine enters the TRANSMIT COLLISION state from any state other than ONE PORT LEFT (Ref: Fig 9-2, IEEE 802.3 Std). The approximate minimum time for rollover of this counter is 16 hours." REFERENCE "Reference IEEE 802.3 Rptr Mgt, 19.2.3.2, aTransmitCollisions." ::= { rptrMonitorRptrInfo 1 } -- -- The Group Monitor Table -- rptrMonitorGroupTable OBJECT-TYPE SYNTAX SEQUENCE OF RptrMonitorGroupEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of performance and error statistics for the groups." ::= { rptrMonitorGroupInfo 1 } rptrMonitorGroupEntry OBJECT-TYPE SYNTAX RptrMonitorGroupEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the table, containing total performance and error statistics for a single group. Regular retrieval of the information in this table provides a means of tracking the performance and health of the networked devices attached to this group's ports. The counters in this table are redundant in the sense that they are the summations of information already available through other objects. However, these sums provide a considerable optimization of network management traffic over the otherwise necessary retrieval of the individual counters included in each sum." INDEX { rptrMonitorGroupIndex } ::= { rptrMonitorGroupTable 1 } RptrMonitorGroupEntry ::= SEQUENCE { rptrMonitorGroupIndex INTEGER, rptrMonitorGroupTotalFrames Counter, rptrMonitorGroupTotalOctets Counter, rptrMonitorGroupTotalErrors Counter } rptrMonitorGroupIndex OBJECT-TYPE SYNTAX INTEGER (1..1024) ACCESS read-only STATUS mandatory DESCRIPTION "This object identifies the group within the repeater for which this entry contains information." ::= { rptrMonitorGroupEntry 1 } rptrMonitorGroupTotalFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of frames of valid frame length that have been received on the ports in this group. This counter is the summation of the values of the rptrMonitorPortReadableFrames counters for all of the ports in the group. This statistic provides one of the parameters necessary for obtaining the packet error rate. The approximate minimum time for rollover of this counter is 80 hours." ::= { rptrMonitorGroupEntry 2 } rptrMonitorGroupTotalOctets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of octets contained in the valid frames that have been received on the ports in this group. This counter is the summation of the values of the rptrMonitorPortReadableOctets counters for all of the ports in the group. This statistic provides an indicator of the total data transferred. The approximate minimum time for rollover of this counter is 58 minutes." ::= { rptrMonitorGroupEntry 3 } rptrMonitorGroupTotalErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of errors which have occurred on all of the ports in this group. This counter is the summation of the values of the rptrMonitorPortTotalErrors counters for all of the ports in the group." ::= { rptrMonitorGroupEntry 4 } -- -- The Port Monitor Table -- rptrMonitorPortTable OBJECT-TYPE SYNTAX SEQUENCE OF RptrMonitorPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of performance and error statistics for the ports." ::= { rptrMonitorPortInfo 1 } rptrMonitorPortEntry OBJECT-TYPE SYNTAX RptrMonitorPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the table, containing performance and error statistics for a single port." INDEX { rptrMonitorPortGroupIndex, rptrMonitorPortIndex } ::= { rptrMonitorPortTable 1 } RptrMonitorPortEntry ::= SEQUENCE { rptrMonitorPortGroupIndex INTEGER, rptrMonitorPortIndex INTEGER, rptrMonitorPortReadableFrames Counter, rptrMonitorPortReadableOctets Counter, rptrMonitorPortFCSErrors Counter, rptrMonitorPortAlignmentErrors Counter, rptrMonitorPortFrameTooLongs Counter, rptrMonitorPortShortEvents Counter, rptrMonitorPortRunts Counter, rptrMonitorPortCollisions Counter, rptrMonitorPortLateEvents Counter, rptrMonitorPortVeryLongEvents Counter, rptrMonitorPortDataRateMismatches Counter, rptrMonitorPortAutoPartitions Counter, rptrMonitorPortTotalErrors Counter } rptrMonitorPortGroupIndex OBJECT-TYPE SYNTAX INTEGER (1..1024) ACCESS read-only STATUS mandatory DESCRIPTION "This object identifies the group containing the port for which this entry contains information." ::= { rptrMonitorPortEntry 1 } rptrMonitorPortIndex OBJECT-TYPE SYNTAX INTEGER (1..1024) ACCESS read-only STATUS mandatory DESCRIPTION "This object identifies the port within the group for which this entry contains information." REFERENCE "Reference IEEE 802.3 Rptr Mgt, 19.2.6.2, aPortID." ::= { rptrMonitorPortEntry 2 } rptrMonitorPortReadableFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object is the number of frames of valid frame length that have been received on this port. This counter is incremented by one for each frame received on this port whose OctetCount is greater than or equal to minFrameSize and less than or equal to maxFrameSize (Ref: IEEE 802.3 Std, 4.4.2.1) and for which the FCSError and CollisionEvent signals are not asserted. This statistic provides one of the parameters necessary for obtaining the packet error rate. The approximate minimum time for rollover of this counter is 80 hours." REFERENCE "Reference IEEE 802.3 Rptr Mgt, 19.2.6.2, aReadableFrames." ::= { rptrMonitorPortEntry 3 } rptrMonitorPortReadableOctets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object is the number of octets contained in valid frames that have been received on this port. This counter is incremented by OctetCount for each frame received on this port which has been determined to be a readable frame. This statistic provides an indicator of the total data transferred. The approximate minimum time for rollover of this counter is 58 minutes." REFERENCE "Reference IEEE 802.3 Rptr Mgt, 19.2.6.2, aReadableOctets." ::= { rptrMonitorPortEntry 4 } rptrMonitorPortFCSErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This counter is incremented by one for each frame received on this port with the FCSError signal asserted and the FramingError and CollisionEvent signals deasserted and whose OctetCount is greater than or equal to minFrameSize and less than or equal to maxFrameSize (Ref: 4.4.2.1, IEEE 802.3 Std). The approximate minimum time for rollover of this counter is 80 hours." REFERENCE "Reference IEEE 802.3 Rptr Mgt, 19.2.6.2, aFrameCheckSequenceErrors." ::= { rptrMonitorPortEntry 5 } rptrMonitorPortAlignmentErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This counter is incremented by one for each frame received on this port with the FCSError and FramingError signals asserted and CollisionEvent signal deasserted and whose OctetCount is greater than or equal to minFrameSize and less than or equal to maxFrameSize (Ref: IEEE 802.3 Std, 4.4.2.1). If rptrMonitorPortAlignmentErrors is incremented then the rptrMonitorPortFCSErrors Counter shall not be incremented for the same frame. The approximate minimum time for rollover of this counter is 80 hours." REFERENCE "Reference IEEE 802.3 Rptr Mgt, 19.2.6.2, aAlignmentErrors." ::= { rptrMonitorPortEntry 6 } rptrMonitorPortFrameTooLongs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This counter is incremented by one for each frame received on this port whose OctetCount is greater than maxFrameSize (Ref: 4.4.2.1, IEEE 802.3 Std). If rptrMonitorPortFrameTooLongs is incremented then neither the rptrMonitorPortAlignmentErrors nor the rptrMonitorPortFCSErrors counter shall be incremented for the frame. The approximate minimum time for rollover of this counter is 61 days." REFERENCE "Reference IEEE 802.3 Rptr Mgt, 19.2.6.2, aFramesTooLong." ::= { rptrMonitorPortEntry 7 } rptrMonitorPortShortEvents OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This counter is incremented by one for each CarrierEvent on this port with ActivityDuration less than ShortEventMaxTime. ShortEventMaxTime is greater than 74 bit times and less than 82 bit times. ShortEventMaxTime has tolerances included to provide for circuit losses between a conformance test point at the AUI and the measurement point within the state machine. Note: shortEvents may indicate externally generated noise hits which will cause the repeater to transmit Runts to its other ports, or propagate a collision (which may be late) back to the transmitting DTE and damaged frames to the rest of the network. Implementors may wish to consider selecting the ShortEventMaxTime towards the lower end of the allowed tolerance range to accommodate bit losses suffered through physical channel devices not budgeted for within this standard. The approximate minimum time for rollover of this counter is 16 hours." REFERENCE "Reference IEEE 802.3 Rptr Mgt, 19.2.6.2, aShortEvents." ::= { rptrMonitorPortEntry 8 } rptrMonitorPortRunts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This counter is incremented by one for each CarrierEvent on this port that meets one of the following two conditions. Only one test need be made. a) The ActivityDuration is greater than ShortEventMaxTime and less than ValidPacketMinTime and the CollisionEvent signal is deasserted. b) The OctetCount is less than 64, the ActivityDuration is greater than ShortEventMaxTime and the CollisionEvent signal is deasserted. ValidPacketMinTime is greater than or equal to 552 bit times and less than 565 bit times. An event whose length is greater than 74 bit times but less than 82 bit times shall increment either the shortEvents counter or the runts counter but not both. A CarrierEvent greater than or equal to 552 bit times but less than 565 bit times may or may not be counted as a runt. ValidPacketMinTime has tolerances included to provide for circuit losses between a conformance test point at the AUI and the measurement point within the state machine. Runts usually indicate collision fragments, a normal network event. In certain situations associated with large diameter networks a percentage of runts may exceed ValidPacketMinTime. The approximate minimum time for rollover of this counter is 16 hours." REFERENCE "Reference IEEE 802.3 Rptr Mgt, 19.2.6.2, aRunts." ::= { rptrMonitorPortEntry 9 } rptrMonitorPortCollisions OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This counter is incremented by one for any CarrierEvent signal on any port for which the CollisionEvent signal on this port is asserted. The approximate minimum time for rollover of this counter is 16 hours." REFERENCE "Reference IEEE 802.3 Rptr Mgt, 19.2.6.2, aCollisions." ::= { rptrMonitorPortEntry 10 } rptrMonitorPortLateEvents OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This counter is incremented by one for each CarrierEvent on this port in which the CollIn(X) variable transitions to the value SQE (Ref: 9.6.6.2, IEEE 802.3 Std) while the ActivityDuration is greater than the LateEventThreshold. Such a CarrierEvent is counted twice, as both a collision and as a lateEvent. The LateEventThreshold is greater than 480 bit times and less than 565 bit times. LateEventThreshold has tolerances included to permit an implementation to build a single threshold to serve as both the LateEventThreshold and ValidPacketMinTime threshold. The approximate minimum time for rollover of this counter is 81 hours." REFERENCE "Reference IEEE 802.3 Rptr Mgt, 19.2.6.2, aLateEvents." ::= { rptrMonitorPortEntry 11 } rptrMonitorPortVeryLongEvents OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This counter is incremented by one for each CarrierEvent on this port whose ActivityDuration is greater than the MAU Jabber Lockup Protection timer TW3 (Ref: 9.6.1 & 9.6.5, IEEE 802.3 Std). Other counters may be incremented as appropriate." REFERENCE "Reference IEEE 802.3 Rptr Mgt, 19.2.6.2, aVeryLongEvents." ::= { rptrMonitorPortEntry 12 } rptrMonitorPortDataRateMismatches OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This counter is incremented by one for each frame received on this port that meets all of the following conditions: a) The CollisionEvent signal is not asserted. b) The ActivityDuration is greater than ValidPacketMinTime. c) The frequency (data rate) is detectably mismatched from the local transmit frequency. The exact degree of mismatch is vendor specific and is to be defined by the vendor for conformance testing. When this event occurs, other counters whose increment conditions were satisfied may or may not also be incremented, at the implementor's discretion. Whether or not the repeater was able to maintain data integrity is beyond the scope of this standard." REFERENCE "Reference IEEE 802.3 Rptr Mgt, 19.2.6.2, aDataRateMismatches." ::= { rptrMonitorPortEntry 13 } rptrMonitorPortAutoPartitions OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This counter is incremented by one for each time the repeater has automatically partitioned this port. The conditions that cause port partitioning are specified in the partition state machine in Section 9 [IEEE 802.3 Std]. They are not differentiated here." REFERENCE "Reference IEEE 802.3 Rptr Mgt, 19.2.6.2, aAutoPartitions." ::= { rptrMonitorPortEntry 14 } rptrMonitorPortTotalErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of errors which have occurred on this port. This counter is the summation of the values of other error counters (for the same port), namely: rptrMonitorPortFCSErrors, rptrMonitorPortAlignmentErrors, rptrMonitorPortFrameTooLongs, rptrMonitorPortShortEvents, rptrMonitorPortLateEvents, rptrMonitorPortVeryLongEvents, and rptrMonitorPortDataRateMismatches. This counter is redundant in the sense that it is the summation of information already available through other objects. However, it is included specifically because the regular retrieval of this object as a means of tracking the health of a port provides a considerable optimization of network management traffic over the otherwise necessary retrieval of the summed counters." ::= { rptrMonitorPortEntry 15 } -- -- The ADDRESS TRACKING GROUP -- -- Implementation of this group is optional; it is appropriate -- for all systems which have the necessary metering. If a -- managed repeater implements any part of this group, the entire -- group shall be implemented. -- -- The Port Address Tracking Table -- rptrAddrTrackTable OBJECT-TYPE SYNTAX SEQUENCE OF RptrAddrTrackEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of address mapping information about the ports." ::= { rptrAddrTrackPortInfo 1 } rptrAddrTrackEntry OBJECT-TYPE SYNTAX RptrAddrTrackEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the table, containing address mapping information about a single port." INDEX { rptrAddrTrackGroupIndex, rptrAddrTrackPortIndex } ::= { rptrAddrTrackTable 1 } RptrAddrTrackEntry ::= SEQUENCE { rptrAddrTrackGroupIndex INTEGER, rptrAddrTrackPortIndex INTEGER, rptrAddrTrackLastSourceAddress MacAddress, rptrAddrTrackSourceAddrChanges Counter } rptrAddrTrackGroupIndex OBJECT-TYPE SYNTAX INTEGER (1..1024) ACCESS read-only STATUS mandatory DESCRIPTION "This object identifies the group containing the port for which this entry contains information." ::= { rptrAddrTrackEntry 1 } rptrAddrTrackPortIndex OBJECT-TYPE SYNTAX INTEGER (1..1024) ACCESS read-only STATUS mandatory DESCRIPTION "This object identifies the port within the group for which this entry contains information." REFERENCE "Reference IEEE 802.3 Rptr Mgt, 19.2.6.2, aPortID." ::= { rptrAddrTrackEntry 2 } rptrAddrTrackLastSourceAddress OBJECT-TYPE SYNTAX MacAddress ACCESS read-only STATUS mandatory DESCRIPTION "This object is the SourceAddress of the last readable frame (i.e., counted by rptrMonitorPortReadableFrames) received by this port." REFERENCE "Reference IEEE 802.3 Rptr Mgt, 19.2.6.2, aLastSourceAddress." ::= { rptrAddrTrackEntry 3 } rptrAddrTrackSourceAddrChanges OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This counter is incremented by one for each time that the rptrAddrTrackLastSourceAddress attribute for this port has changed. This may indicate whether a link is connected to a single DTE or another multi-user segment. The approximate minimum time for rollover of this counter is 81 hours." REFERENCE "Reference IEEE 802.3 Rptr Mgt, 19.2.6.2, aSourceAddressChanges." ::= { rptrAddrTrackEntry 4 } -- Traps for use by Repeaters -- Traps are defined using the conventions in RFC 1215 [8]. rptrHealth TRAP-TYPE ENTERPRISE snmpDot3RptrMgt VARIABLES { rptrOperStatus } DESCRIPTION "The rptrHealth trap conveys information related to the operational status of the repeater. This trap is sent only when the oper status of the repeater changes. The rptrHealth trap must contain the rptrOperStatus object. The agent may optionally include the rptrHealthText object in the varBind list. See the rptrOperStatus and rptrHealthText objects for descriptions of the information that is sent. The agent must throttle the generation of consecutive rptrHealth traps so that there is at least a five-second gap between them." REFERENCE "Reference IEEE 802.3 Rptr Mgt, 19.2.3.4, hubHealth notification." ::= 1 rptrGroupChange TRAP-TYPE ENTERPRISE snmpDot3RptrMgt VARIABLES { rptrGroupIndex } DESCRIPTION "This trap is sent when a change occurs in the group structure of a repeater. This occurs only when a group is logically or physically removed from or added to a repeater. The varBind list contains the identifier of the group that was removed or added. The agent must throttle the generation of consecutive rptrGroupChange traps for the same group so that there is at least a five-second gap between them." REFERENCE "Reference IEEE 802.3 Rptr Mgt, 19.2.3.4, groupMapChange notification." ::= 2 rptrResetEvent TRAP-TYPE ENTERPRISE snmpDot3RptrMgt VARIABLES { rptrOperStatus } DESCRIPTION "The rptrResetEvent trap conveys information related to the operational status of the repeater. This trap is sent on completion of a repeater reset action. A repeater reset action is defined as an a transition to the START state of Fig 9-2 in section 9 [IEEE 802.3 Std], when triggered by a management command (e.g., an SNMP Set on the rptrReset object). The agent must throttle the generation of consecutive rptrResetEvent traps so that there is at least a five-second gap between them. The rptrResetEvent trap is not sent when the agent restarts and sends an SNMP coldStart or warmStart trap. However, it is recommended that a repeater agent send the rptrOperStatus object as an optional object with its coldStart and warmStart trap PDUs. The rptrOperStatus object must be included in the varbind list sent with this trap. The agent may optionally include the rptrHealthText object as well." REFERENCE "Reference IEEE 802.3 Rptr Mgt, 19.2.3.4, hubReset notification." ::= 3 -- -- FILE: /bigguy/users/craig/mibs/src/other/lanart.mib -- lanart OBJECT IDENTIFIER ::= { enterprises 712 } laMib1 OBJECT IDENTIFIER ::= { lanart 1 } laProducts OBJECT IDENTIFIER ::= { laMib1 1 } laHubMib OBJECT IDENTIFIER ::= { laMib1 2 } laSys OBJECT IDENTIFIER ::= { laHubMib 1 } laTpPort OBJECT IDENTIFIER ::= { laHubMib 2 } -- The following OIDs are used in sysOID -- laTpHub OBJECT IDENTIFIER ::= { laProducts 1 } -- The following OIDs are used in groupOID -- -- laTpHub[1-3] were added to fill in missing nodes in the OID tree. laTpHub1 OBJECT IDENTIFIER ::= { laTpHub 1 } etm120x OBJECT IDENTIFIER ::= { laTpHub1 12 } etm160x OBJECT IDENTIFIER ::= { laTpHub1 16 } etm240x OBJECT IDENTIFIER ::= { laTpHub1 24 } laTpHub2 OBJECT IDENTIFIER ::= { laTpHub 2 } ete120x OBJECT IDENTIFIER ::= { laTpHub2 12 } ete160x OBJECT IDENTIFIER ::= { laTpHub2 16 } ete240x OBJECT IDENTIFIER ::= { laTpHub2 24 } laTpHub3 OBJECT IDENTIFIER ::= { laTpHub 3 } bbAui OBJECT IDENTIFIER ::= { laTpHub3 0 } bbAuiTp OBJECT IDENTIFIER ::= { laTpHub3 1 } bbAuiBnc OBJECT IDENTIFIER ::= { laTpHub3 2 } bbAuiTpBnc OBJECT IDENTIFIER ::= { laTpHub3 3 } bbAui10BASE-FL OBJECT IDENTIFIER ::= { laTpHub3 4 } laSysConfig OBJECT-TYPE SYNTAX INTEGER { save(1), load(2), factory(3), ok(4), failed(5) } ACCESS read-write STATUS mandatory DESCRIPTION "Setting this object to save(1) will save all configuration variables to non-volatile memory. Setting this object to load(2) will configure the hub according to the stored configuration. Setting this object to factory(3) will configure the hub according to the factory settings. A return value of ok(4) means the non-volatile memory is operational. A return value of failed(5) means the non-volatile memory has failed." ::= { laSys 1 } laJoystick OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Setting this object to disabled(2) prevents use of the four-position switch on the front panel. Resetting this object to enabled(1) allows use of the switch." ::= { laSys 2 } laLinkAlert OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2), not-applicable(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Setting this object enables or disables the LinkALERT feature of the backbone 10BASE-T or 10BASE-FL port. A return value of not-applicable indicates that none of the backbone ports feature LinkALERT." ::= { laSys 3 } laTpPortTable OBJECT-TYPE SYNTAX SEQUENCE OF LaTpPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of descriptive and status information about the ports." ::= { laTpPort 1 } laTpPortEntry OBJECT-TYPE SYNTAX LaTpPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the table, containing information about a single port." INDEX { laTpPortGroupIndex, laTpPortIndex } ::= { laTpPortTable 1 } LaTpPortEntry ::= SEQUENCE { laTpPortGroupIndex INTEGER, laTpPortIndex INTEGER, laTpLinkTest INTEGER, laTpAutoPolarity INTEGER } laTpPortGroupIndex OBJECT-TYPE SYNTAX INTEGER (1..1024) ACCESS read-only STATUS mandatory DESCRIPTION "This object identifies the group containing the port for which this entry contains information." ::= { laTpPortEntry 1 } laTpPortIndex OBJECT-TYPE SYNTAX INTEGER (1..1024) ACCESS read-only STATUS mandatory DESCRIPTION "This object identifies the port within the group for which this entry contains information." ::= { laTpPortEntry 2 } laTpLinkTest OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2), failed(3), not-applicable(4) } ACCESS read-write STATUS mandatory DESCRIPTION "Setting this object to disabled(2) disables the link test feature. This may be useful for interoperation with pre-10BASE-T equipment. Setting this object to enabled(1) enables the feature. A return value of failed(3) indicates a link test failure for this port. A return value of not-applicable(4) indicates that the specified port does not have a link test." ::= { laTpPortEntry 3 } laTpAutoPolarity OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2), corrected(3), not-applicable(4) } ACCESS read-write STATUS mandatory DESCRIPTION "Setting this object to disabled(2) disables the auto polarity test for this port. Setting this object to enabled(1) enables the feature. A return value of corrected(3) indicates that the polarity test has sensed a reversal on the receive wiring pair, and has corrected this fault by inverting its receive signal. A return value of not-applicable(4) indicates that the specified port does not support polarity correction." ::= { laTpPortEntry 4 } END